bwf approved fire door inspectors - asfp seminar 2014/3. jf doors.pdf · fire doors are essential...
TRANSCRIPT
![Page 1: BWF Approved Fire Door Inspectors - ASFP seminar 2014/3. JF Doors.pdf · Fire doors are essential in passive fire protection A requirement in compartmenting a building ... and light](https://reader031.vdocument.in/reader031/viewer/2022030509/5ab9727a7f8b9ad5338df800/html5/thumbnails/1.jpg)
Fire Doors The Role of a Fire Door
BWF-Certifire Fire Door and Doorset Scheme
Presented by John Fletcher John Fletcher Consulting Ltd.
![Page 2: BWF Approved Fire Door Inspectors - ASFP seminar 2014/3. JF Doors.pdf · Fire doors are essential in passive fire protection A requirement in compartmenting a building ... and light](https://reader031.vdocument.in/reader031/viewer/2022030509/5ab9727a7f8b9ad5338df800/html5/thumbnails/2.jpg)
Fire doors – main messages
1. Fire doors are essential in passive fire protection A requirement in compartmenting a building
Protecting escape routes
Save Lives – Save Property
2. Must be tested to show the design will work in a fire. What do we mean by certification?
3. Fire doors can only work correctly when . . . . Fitted with the correct compatible components for the door
Door leaf + frame / linings
Closers, Hinges and other ESSENTIAL ironmongery
Seals
Glazing
I.e. the fire door assembly / or doorset must comply with regulations
4. Where to go for help & information If in doubt - DON”T GUESS!
2
![Page 3: BWF Approved Fire Door Inspectors - ASFP seminar 2014/3. JF Doors.pdf · Fire doors are essential in passive fire protection A requirement in compartmenting a building ... and light](https://reader031.vdocument.in/reader031/viewer/2022030509/5ab9727a7f8b9ad5338df800/html5/thumbnails/3.jpg)
A partnership
BWF - a Trade Association
The BWF-CERTIFIRE Fire Door and Doorset Scheme Began in 1997
Around 200 members
An alliance across the Fire Door Industry Door leaf and doorset manufacturers Frame manufacturers Licensed modifiers Ironmongery manufacturers/distributors Seal manufacturers Fire door glass / glazing system providers Suppliers
Door blanks / cores Glass
Merchants and Distributors
CERTIFIRE - A Certification Body
Other 3rd party certification schemes
e.g. TRADA Q Mark & IFC
![Page 4: BWF Approved Fire Door Inspectors - ASFP seminar 2014/3. JF Doors.pdf · Fire doors are essential in passive fire protection A requirement in compartmenting a building ... and light](https://reader031.vdocument.in/reader031/viewer/2022030509/5ab9727a7f8b9ad5338df800/html5/thumbnails/4.jpg)
Industry Aims & Challenges • To improve the standard of fire doors installed in the UK
• To educate the construction industry about the importance of
third-party certification of fire doors and passive fire protection
systems
• To raise awareness and educate the consumers, and users of the
critical importance of Fire Doors
• To move the market progressively towards fire doorsets as
the best way to achieve the Scheme long-term objectives
Our Challenges
• 3 million fire doors sold per year
• Common supply route via merchants - approx 80%
• Changing the spec “to save the client money” • Cutting costs / cutting corners
• Poor understanding, poor maintenance, poor workmanship
• Fire doors are an engineered safety device – not ‘just an ordinary door’
4
![Page 5: BWF Approved Fire Door Inspectors - ASFP seminar 2014/3. JF Doors.pdf · Fire doors are essential in passive fire protection A requirement in compartmenting a building ... and light](https://reader031.vdocument.in/reader031/viewer/2022030509/5ab9727a7f8b9ad5338df800/html5/thumbnails/5.jpg)
Poor workmanship Gaps - between doors, frame-to-wall, leaf to frame
![Page 6: BWF Approved Fire Door Inspectors - ASFP seminar 2014/3. JF Doors.pdf · Fire doors are essential in passive fire protection A requirement in compartmenting a building ... and light](https://reader031.vdocument.in/reader031/viewer/2022030509/5ab9727a7f8b9ad5338df800/html5/thumbnails/6.jpg)
Poor workmanship & poor advice
![Page 7: BWF Approved Fire Door Inspectors - ASFP seminar 2014/3. JF Doors.pdf · Fire doors are essential in passive fire protection A requirement in compartmenting a building ... and light](https://reader031.vdocument.in/reader031/viewer/2022030509/5ab9727a7f8b9ad5338df800/html5/thumbnails/7.jpg)
Does someone
REALLY believe
this will work in a
fire?
Poor maintenance
![Page 8: BWF Approved Fire Door Inspectors - ASFP seminar 2014/3. JF Doors.pdf · Fire doors are essential in passive fire protection A requirement in compartmenting a building ... and light](https://reader031.vdocument.in/reader031/viewer/2022030509/5ab9727a7f8b9ad5338df800/html5/thumbnails/8.jpg)
Photos by kind
permission of
CheckMate Ltd
Poor understanding
![Page 9: BWF Approved Fire Door Inspectors - ASFP seminar 2014/3. JF Doors.pdf · Fire doors are essential in passive fire protection A requirement in compartmenting a building ... and light](https://reader031.vdocument.in/reader031/viewer/2022030509/5ab9727a7f8b9ad5338df800/html5/thumbnails/9.jpg)
Wedged / held open fire doors
![Page 10: BWF Approved Fire Door Inspectors - ASFP seminar 2014/3. JF Doors.pdf · Fire doors are essential in passive fire protection A requirement in compartmenting a building ... and light](https://reader031.vdocument.in/reader031/viewer/2022030509/5ab9727a7f8b9ad5338df800/html5/thumbnails/10.jpg)
Understanding the signage
![Page 11: BWF Approved Fire Door Inspectors - ASFP seminar 2014/3. JF Doors.pdf · Fire doors are essential in passive fire protection A requirement in compartmenting a building ... and light](https://reader031.vdocument.in/reader031/viewer/2022030509/5ab9727a7f8b9ad5338df800/html5/thumbnails/11.jpg)
Adapting / accommodating fire doors to suit premises
![Page 12: BWF Approved Fire Door Inspectors - ASFP seminar 2014/3. JF Doors.pdf · Fire doors are essential in passive fire protection A requirement in compartmenting a building ... and light](https://reader031.vdocument.in/reader031/viewer/2022030509/5ab9727a7f8b9ad5338df800/html5/thumbnails/12.jpg)
What are fire doors for?
![Page 13: BWF Approved Fire Door Inspectors - ASFP seminar 2014/3. JF Doors.pdf · Fire doors are essential in passive fire protection A requirement in compartmenting a building ... and light](https://reader031.vdocument.in/reader031/viewer/2022030509/5ab9727a7f8b9ad5338df800/html5/thumbnails/13.jpg)
What fire doors do
2. In the event of a fire • A requirement in compartmenting a
building • Protecting escape routes • Restricting initial development of a
fire. E.g restricting the amount of oxygen feeding the fire
Fire doors serve 2 purposes 1. Everyday activity • Allowing passage in and out of a
building / section of a building or a room
![Page 14: BWF Approved Fire Door Inspectors - ASFP seminar 2014/3. JF Doors.pdf · Fire doors are essential in passive fire protection A requirement in compartmenting a building ... and light](https://reader031.vdocument.in/reader031/viewer/2022030509/5ab9727a7f8b9ad5338df800/html5/thumbnails/14.jpg)
2 types of fire door installations
• In the UK, a fire door installation is
achieved in one of two ways:-
Doorset:
o frame, a pre-hung door leaf (with
any vision panels) and essential
ironmongery, all matched and
pre-assembled in the factory
Door Assembly:
o a fire door leaf, frame and
additional components needed to
install them, supplied and fitted
separately.
In the latter case, the components that are fitted MUST match the test
evidence. I.e. They MUST be compatible with the door leaf
![Page 15: BWF Approved Fire Door Inspectors - ASFP seminar 2014/3. JF Doors.pdf · Fire doors are essential in passive fire protection A requirement in compartmenting a building ... and light](https://reader031.vdocument.in/reader031/viewer/2022030509/5ab9727a7f8b9ad5338df800/html5/thumbnails/15.jpg)
Door leaf – standard practice
Fire door assembly Fire door leaf / approved frame / casing Compatible Approved Components
Door leaf
Door
frame /
casing
/ lining CE marked Certifire Approved components –
compatible with door test
![Page 16: BWF Approved Fire Door Inspectors - ASFP seminar 2014/3. JF Doors.pdf · Fire doors are essential in passive fire protection A requirement in compartmenting a building ... and light](https://reader031.vdocument.in/reader031/viewer/2022030509/5ab9727a7f8b9ad5338df800/html5/thumbnails/16.jpg)
Regulations
What regulations apply to fire doors?
![Page 17: BWF Approved Fire Door Inspectors - ASFP seminar 2014/3. JF Doors.pdf · Fire doors are essential in passive fire protection A requirement in compartmenting a building ... and light](https://reader031.vdocument.in/reader031/viewer/2022030509/5ab9727a7f8b9ad5338df800/html5/thumbnails/17.jpg)
The Building Regulations
Fire doors should have the appropriate performance - given by Test BS 476 Part 22
Classification BS EN 13501 / Test BS EN 1634 – 1/2/3
Any test evidence used to substantiate the fire
resistance rating of a door or shutter should be carefully checked to ensure that it adequately demonstrates compliance that is applicable to the complete installed assembly. Small differences in detail (such as glazing apertures, intumescent strips, door frames and ironmongery etc.) may significantly affect the rating.
![Page 18: BWF Approved Fire Door Inspectors - ASFP seminar 2014/3. JF Doors.pdf · Fire doors are essential in passive fire protection A requirement in compartmenting a building ... and light](https://reader031.vdocument.in/reader031/viewer/2022030509/5ab9727a7f8b9ad5338df800/html5/thumbnails/18.jpg)
Building Regulations New buildings
UK Regulatory Parts
Performance Notes
England &
Wales :
Approved
Documents
Scotland :
Technical
Handbook :
sections
Northern Ireland
: Technichal
Booklets
Fire Safety
- Where a fire door is required
- The fire resistance period
expected
- Specific requirements e.g.
smoke seals and signage
B 2 E
Sound - Minimum sound resistance
performance of the door E 5 G
Ventilation - Minimum air transfer gap
required under the door F 3 K
Thermal - Minimum thermal performance
of the door if required L 6 F
Accessibility
- Access to buildings for disabled
people, including door width,
hardware locations, opening
forces, provision of vision panels
and light reflectance values
required
M 3 R
Safety
Glazing
- Where safety glass is required N 4 V
![Page 19: BWF Approved Fire Door Inspectors - ASFP seminar 2014/3. JF Doors.pdf · Fire doors are essential in passive fire protection A requirement in compartmenting a building ... and light](https://reader031.vdocument.in/reader031/viewer/2022030509/5ab9727a7f8b9ad5338df800/html5/thumbnails/19.jpg)
Regulatory Reform Order (2005) Existing buildings
Applies to England and Wales:
Fire (Scotland) Act
• Premises that provide care including care homes and hospitals
• Community halls, places of worship and other community premises
• The shared areas of properties occupied by several households
• Pubs, clubs and restaurants
• Schools and sports centres
• Tents and marquees
• Hotels and hostels
• Factories and warehouses
![Page 20: BWF Approved Fire Door Inspectors - ASFP seminar 2014/3. JF Doors.pdf · Fire doors are essential in passive fire protection A requirement in compartmenting a building ... and light](https://reader031.vdocument.in/reader031/viewer/2022030509/5ab9727a7f8b9ad5338df800/html5/thumbnails/20.jpg)
The Missing Link - Building handover requirements
(Regulation 38 – England and Wales)
New build
Client Ownership
Handing over the correct information about the certification of
the fire door and components is extremely important for future
inspection & maintenance
![Page 21: BWF Approved Fire Door Inspectors - ASFP seminar 2014/3. JF Doors.pdf · Fire doors are essential in passive fire protection A requirement in compartmenting a building ... and light](https://reader031.vdocument.in/reader031/viewer/2022030509/5ab9727a7f8b9ad5338df800/html5/thumbnails/21.jpg)
Understanding certification
What does it tell us?
How do we know it’s correct or up-to-date?
![Page 22: BWF Approved Fire Door Inspectors - ASFP seminar 2014/3. JF Doors.pdf · Fire doors are essential in passive fire protection A requirement in compartmenting a building ... and light](https://reader031.vdocument.in/reader031/viewer/2022030509/5ab9727a7f8b9ad5338df800/html5/thumbnails/22.jpg)
Doors should be tested & certificated?
You need proof of performance Comply with building regs.
A test certificate indicates that the complete door assembly can withhold fire for a defined period of time
What many fail to realise - that the complete assembly must be installed as it was tested Components as well as door Applies to each door configuration
requires a proof
How do I know if the door is a fire door? Label Plug Proof of test evidence
What if you have none of these? then there’s a doubt about the door’s ability to perform An ‘expert’ assessment can be made
But it’s expensive
![Page 23: BWF Approved Fire Door Inspectors - ASFP seminar 2014/3. JF Doors.pdf · Fire doors are essential in passive fire protection A requirement in compartmenting a building ... and light](https://reader031.vdocument.in/reader031/viewer/2022030509/5ab9727a7f8b9ad5338df800/html5/thumbnails/23.jpg)
3 ways of demonstrating compliance The difference . . . .
Self declaration
“Tested to / Designed to /
Complies with BS 476 Part 22”
No guarantee that products will (or have)
reached the correct standards
May not have been tested
Was the test impartial?
What about ongoing manufacture?
Test certificate
“My product was tested.”
“I have a certificate”
Only a SNAPSHOT test
Was the test sample representative of what is ALWAYS produced?
What if manufacturing changes?
What if designs change?
What if materials change?
3rd party certification
Not only demonstrates product conformity
Audits the company’s production & product
Ensures the product is supplied to the SAME specification / design
AS TESTED
= CONFIDENCE
Uncertain? = RISK
Uncertain? = RISK
![Page 24: BWF Approved Fire Door Inspectors - ASFP seminar 2014/3. JF Doors.pdf · Fire doors are essential in passive fire protection A requirement in compartmenting a building ... and light](https://reader031.vdocument.in/reader031/viewer/2022030509/5ab9727a7f8b9ad5338df800/html5/thumbnails/24.jpg)
3rd party certification Warrington Certification is the UKAS test
laboratory who conduct independent
testing of doors and components and audit
check members
Doors +
components can
be traced up or
down the supply
chain
The performance of timber doors is judged by subjecting them to the standard test procedure specified in BS 476 : Part 22: 1987 or BS EN 1634-1: 2014. Tests are made on complete door assemblies, the door and frame with all the necessary hardware.
![Page 25: BWF Approved Fire Door Inspectors - ASFP seminar 2014/3. JF Doors.pdf · Fire doors are essential in passive fire protection A requirement in compartmenting a building ... and light](https://reader031.vdocument.in/reader031/viewer/2022030509/5ab9727a7f8b9ad5338df800/html5/thumbnails/25.jpg)
Fire Door Certificates
What to look for . . . 1. Does the door have any identity or
marking to validate compliance / certification?
• A plug • A label • A specific door reference
2. Is the certification number / evidence
relevant to the door leaf / door set? • Obvious!! But you’d be surprised
how rarely it’s checked
3. Is the door type / configuration correct?
• Single / pair
• Panel / flush etc.
1. Who glazed the door?
• If not done correctly, the certificate will be void
![Page 26: BWF Approved Fire Door Inspectors - ASFP seminar 2014/3. JF Doors.pdf · Fire doors are essential in passive fire protection A requirement in compartmenting a building ... and light](https://reader031.vdocument.in/reader031/viewer/2022030509/5ab9727a7f8b9ad5338df800/html5/thumbnails/26.jpg)
Door types
You may have specified an FD30 door, but . . .
Each door type below requires a different construction - AND a different test
It MAY NOT be suitable some configurations, certain components or for glazing
Panel Moulded
Panel Flush Glazed 1 ½ pair
with screen
![Page 27: BWF Approved Fire Door Inspectors - ASFP seminar 2014/3. JF Doors.pdf · Fire doors are essential in passive fire protection A requirement in compartmenting a building ... and light](https://reader031.vdocument.in/reader031/viewer/2022030509/5ab9727a7f8b9ad5338df800/html5/thumbnails/27.jpg)
Each door configuration is subjected to a different fire door test.
You cannot assume that any 2 single doors will work in a double leaf system
Door configurations
![Page 28: BWF Approved Fire Door Inspectors - ASFP seminar 2014/3. JF Doors.pdf · Fire doors are essential in passive fire protection A requirement in compartmenting a building ... and light](https://reader031.vdocument.in/reader031/viewer/2022030509/5ab9727a7f8b9ad5338df800/html5/thumbnails/28.jpg)
Ironmongery for Fire Doors must be compatible with the door
Essential Ironmongery
• Hinges
• Closers
• Locks and latches
Non-Essential Ironmongery
Handles
Knobs
Spy holes
Letter plates
![Page 29: BWF Approved Fire Door Inspectors - ASFP seminar 2014/3. JF Doors.pdf · Fire doors are essential in passive fire protection A requirement in compartmenting a building ... and light](https://reader031.vdocument.in/reader031/viewer/2022030509/5ab9727a7f8b9ad5338df800/html5/thumbnails/29.jpg)
Where do I find the information about the door leaf and components?
Installation & maintenance
instructions supplied with
EVERY door
![Page 30: BWF Approved Fire Door Inspectors - ASFP seminar 2014/3. JF Doors.pdf · Fire doors are essential in passive fire protection A requirement in compartmenting a building ... and light](https://reader031.vdocument.in/reader031/viewer/2022030509/5ab9727a7f8b9ad5338df800/html5/thumbnails/30.jpg)
Where do I find the information about the door leaf and components?
![Page 31: BWF Approved Fire Door Inspectors - ASFP seminar 2014/3. JF Doors.pdf · Fire doors are essential in passive fire protection A requirement in compartmenting a building ... and light](https://reader031.vdocument.in/reader031/viewer/2022030509/5ab9727a7f8b9ad5338df800/html5/thumbnails/31.jpg)
Checking the assembly
What to look for – after installation and in use
![Page 32: BWF Approved Fire Door Inspectors - ASFP seminar 2014/3. JF Doors.pdf · Fire doors are essential in passive fire protection A requirement in compartmenting a building ... and light](https://reader031.vdocument.in/reader031/viewer/2022030509/5ab9727a7f8b9ad5338df800/html5/thumbnails/32.jpg)
The Door Leaf Does the door have a certificate?
Is it 3rd-party certificated?
Does the door leaf sit in the door frame?
Is it free from distortion?
Is the door leaf free from damage?
No cracked / split panels
If the door leaf is veneered or lipped, is the glue still holding these products firmly in place?
Don’t consider upgrading an ordinary door with intumescent paints
It’s a very specialised job
You can’t apply the paint accurately enough with a paint brush
Don’t patch up the door
![Page 33: BWF Approved Fire Door Inspectors - ASFP seminar 2014/3. JF Doors.pdf · Fire doors are essential in passive fire protection A requirement in compartmenting a building ... and light](https://reader031.vdocument.in/reader031/viewer/2022030509/5ab9727a7f8b9ad5338df800/html5/thumbnails/33.jpg)
Door Frame
Is the door frame made from the right material?
Softwood (possibly MDF) for FD30 Hardwood for FD60 hour and above
Is the door frame firmly attached to the wall? Any SMALL gaps should filled with mineral wool or
fire rated material
Is the frame’s planted stop firmly attached to the frame?
Does the door close evenly into the frame
![Page 34: BWF Approved Fire Door Inspectors - ASFP seminar 2014/3. JF Doors.pdf · Fire doors are essential in passive fire protection A requirement in compartmenting a building ... and light](https://reader031.vdocument.in/reader031/viewer/2022030509/5ab9727a7f8b9ad5338df800/html5/thumbnails/34.jpg)
The gap is important
The frame to door leaf gap should be
3 to 4mm at the two sides and top
edge of the door
![Page 35: BWF Approved Fire Door Inspectors - ASFP seminar 2014/3. JF Doors.pdf · Fire doors are essential in passive fire protection A requirement in compartmenting a building ... and light](https://reader031.vdocument.in/reader031/viewer/2022030509/5ab9727a7f8b9ad5338df800/html5/thumbnails/35.jpg)
Threshold Gap
If a Fire Door – the permissible threshold gap is ~ 10mm. (Check the manufacturer’s instructions / evidence)
If a Fire and Smoke Door – the permissible threshold gap should be 3 to 4mm – the same as the perimeter gap.
Does the door freely swing, without binding?
![Page 36: BWF Approved Fire Door Inspectors - ASFP seminar 2014/3. JF Doors.pdf · Fire doors are essential in passive fire protection A requirement in compartmenting a building ... and light](https://reader031.vdocument.in/reader031/viewer/2022030509/5ab9727a7f8b9ad5338df800/html5/thumbnails/36.jpg)
Intumescent and smoke seals
Must be tested to BS 476: Pt 22
(OR BS EN 1634-1:2014 AND a separate test for smoke leakage under BS 476:
Pt 31.1)
Typically fitted into groove in door leaf OR PREFERABLY frame.
Fitted along 2 vertical sections and top edge
not fitted to threshold
Ideally, should be supplied, fitted by doorframe manufacturer.
If replaced due to repair MUST be equal to original doorset / assembly
Save lives, and property - prevent flow of cold / hot smoke
Many doorsets now need to provide fire, smoke and acoustic
containment
36
![Page 37: BWF Approved Fire Door Inspectors - ASFP seminar 2014/3. JF Doors.pdf · Fire doors are essential in passive fire protection A requirement in compartmenting a building ... and light](https://reader031.vdocument.in/reader031/viewer/2022030509/5ab9727a7f8b9ad5338df800/html5/thumbnails/37.jpg)
Fire & Smoke Seals
Is the Fire Door an FD30(S) or an FD60(S)? There is very limited substitution on FD30’s
and no substitution allowed on FD60’s
Are there any seals present in the door leaf or frame?
Are the seals free from damage? Are the seals continuous around the door leaf’s
perimeter? Are the intumescent seals, graphite or sodium
silicate? Don’t mix them
If combined fire and smoke seals, are the fins or brushes free from damage?
Is the door leaf to frame gap still 3 to 4 mm?
![Page 38: BWF Approved Fire Door Inspectors - ASFP seminar 2014/3. JF Doors.pdf · Fire doors are essential in passive fire protection A requirement in compartmenting a building ... and light](https://reader031.vdocument.in/reader031/viewer/2022030509/5ab9727a7f8b9ad5338df800/html5/thumbnails/38.jpg)
Intumescent Materials 3 main types
Exfoliating Graphite Most common type, 17 different types. Expansion between 170 – 300 °C High pressure seal, multi directional expansion
Hydrated Sodium Silicate Chemical formula, consistent in its performance Expands at 100 °C , consistently High pressure seal, multi directional expansion
Mono-Ammonium Phosphate Referred to as MAP Low pressure, high volume expansion
Commonly used for lock/latch and hinge protection kits
![Page 39: BWF Approved Fire Door Inspectors - ASFP seminar 2014/3. JF Doors.pdf · Fire doors are essential in passive fire protection A requirement in compartmenting a building ... and light](https://reader031.vdocument.in/reader031/viewer/2022030509/5ab9727a7f8b9ad5338df800/html5/thumbnails/39.jpg)
Glazing Detail
Are the glazing beads well attached to the door leaf and free from damage?
Is the glass free from damage and cracking?
Is the intumescent glazing seal continuous and attached to both the glass and bead?
If the glass is below 1500mm from the bottom of the door is the glass a fire- rated safety glass?
Who cut the vision panel & installed the glass? Check for a second label or a plug
![Page 40: BWF Approved Fire Door Inspectors - ASFP seminar 2014/3. JF Doors.pdf · Fire doors are essential in passive fire protection A requirement in compartmenting a building ... and light](https://reader031.vdocument.in/reader031/viewer/2022030509/5ab9727a7f8b9ad5338df800/html5/thumbnails/40.jpg)
Unprotected
slots and
apertures
Other apertures
in doors
Letter boxes
Air transfer grilles
Spy-hole viewers
Should be cut & fitted by
approved installers
![Page 41: BWF Approved Fire Door Inspectors - ASFP seminar 2014/3. JF Doors.pdf · Fire doors are essential in passive fire protection A requirement in compartmenting a building ... and light](https://reader031.vdocument.in/reader031/viewer/2022030509/5ab9727a7f8b9ad5338df800/html5/thumbnails/41.jpg)
Fire Rated ATG’s
On an FD30 or FD60: remove cover grille and check that a Fire Resistant air transfer grille has been fitted (giving hot smoke protection)
Ensure the ATG is free of blockages, replace if necessary.
If an FD30S or FD60S: ensure electro-mechanical device has been fitted (giving cold smoke protection) and works!
Periodic checks must be conducted with the fire/smoke alarm tests weekly (as required in RRO).
Does the vent automatically shut down when the power to the door is cut?
Ensure the electro-mechanical ATG is free of blockages
![Page 42: BWF Approved Fire Door Inspectors - ASFP seminar 2014/3. JF Doors.pdf · Fire doors are essential in passive fire protection A requirement in compartmenting a building ... and light](https://reader031.vdocument.in/reader031/viewer/2022030509/5ab9727a7f8b9ad5338df800/html5/thumbnails/42.jpg)
Check / maintain the ironmongery Replace if necessary
Essential Ironmongery
• Hinges
• Closers
• Locks and latches
Non-Essential Ironmongery
Handles
Knobs
Spy holes
Letter plates
![Page 43: BWF Approved Fire Door Inspectors - ASFP seminar 2014/3. JF Doors.pdf · Fire doors are essential in passive fire protection A requirement in compartmenting a building ... and light](https://reader031.vdocument.in/reader031/viewer/2022030509/5ab9727a7f8b9ad5338df800/html5/thumbnails/43.jpg)
Conclusion
The role of Fire Doors?
![Page 44: BWF Approved Fire Door Inspectors - ASFP seminar 2014/3. JF Doors.pdf · Fire doors are essential in passive fire protection A requirement in compartmenting a building ... and light](https://reader031.vdocument.in/reader031/viewer/2022030509/5ab9727a7f8b9ad5338df800/html5/thumbnails/44.jpg)
The role of fire doors?
Conclusion 1. Only specify / use 3rd-party certificated fire doors
2. Ensure they are installed / maintained by competent persons
3. Get them checked or inspected by competent personnel
4. ONLY use the correct compatible components for the door leaf
5. Don’t play with fire - don’t cut corners
6. If in ANY DOUBT, then ASK
![Page 45: BWF Approved Fire Door Inspectors - ASFP seminar 2014/3. JF Doors.pdf · Fire doors are essential in passive fire protection A requirement in compartmenting a building ... and light](https://reader031.vdocument.in/reader031/viewer/2022030509/5ab9727a7f8b9ad5338df800/html5/thumbnails/45.jpg)
Further Information
www.bwfcertifire.org.uk
Directory of members - Literature and Fact Cards
![Page 46: BWF Approved Fire Door Inspectors - ASFP seminar 2014/3. JF Doors.pdf · Fire doors are essential in passive fire protection A requirement in compartmenting a building ... and light](https://reader031.vdocument.in/reader031/viewer/2022030509/5ab9727a7f8b9ad5338df800/html5/thumbnails/46.jpg)
Check the certificate details
![Page 47: BWF Approved Fire Door Inspectors - ASFP seminar 2014/3. JF Doors.pdf · Fire doors are essential in passive fire protection A requirement in compartmenting a building ... and light](https://reader031.vdocument.in/reader031/viewer/2022030509/5ab9727a7f8b9ad5338df800/html5/thumbnails/47.jpg)
Consistent approach to inspections Competent Approved Fire Door Inspectors (FDIS)
![Page 48: BWF Approved Fire Door Inspectors - ASFP seminar 2014/3. JF Doors.pdf · Fire doors are essential in passive fire protection A requirement in compartmenting a building ... and light](https://reader031.vdocument.in/reader031/viewer/2022030509/5ab9727a7f8b9ad5338df800/html5/thumbnails/48.jpg)
Look out for 2 further initiatives
15–20 SEPTEMBER 2014
A national register of third-party
certificated fire door installers
www.firedoorinstaller.co.uk
(Under Construction)
![Page 49: BWF Approved Fire Door Inspectors - ASFP seminar 2014/3. JF Doors.pdf · Fire doors are essential in passive fire protection A requirement in compartmenting a building ... and light](https://reader031.vdocument.in/reader031/viewer/2022030509/5ab9727a7f8b9ad5338df800/html5/thumbnails/49.jpg)
THANK YOU
Your attention is appreciated!