c-dot mbm-xl overview...introduction c-dot mbm-xl overview covers the hardware architecture and...

38
C-DOT MBM-XL OVERVIEW S.K.TYAGI ALTTC, Ghaziabad

Upload: others

Post on 15-Mar-2020

14 views

Category:

Documents


0 download

TRANSCRIPT

C-DOT MBM-XL OVERVIEW

S.K.TYAGIALTTC, Ghaziabad

Introduction

C-DOT MBM-XL OVERVIEW COVERS THE HARDWARE ARCHITECTURE AND FEATURES OF THE C-DOT MBM-XL SWITCHING SYSTEMIT COVERS THE DIFFERENT USES OF THIS SYSTEM IN THE NETWORKCCS#7 & ISDN IMPLEMENTATION IN C-DOT WILL ALSO BE DISCUSSED

C-DOT MBM-XL ARCHITECTURE

AM

BM1

BM

n

CMMDF

IOM

ADP

DISK TAPE VDUPRINTER

SUBSCRIBER LINES

ANALOG TRUNKS

DIGITAL TRUNKS

DIGITAL LINKS FORM RSUs

C-DOT SBM-XL

LINE MODULE BASE MODULE LINE MODULE

Time Switch Unit

Base Processor Unit

Terminal Unit

Terminal Unit

Terminal Unit

Terminal UnitTerminal Unit

Terminal Unit

Terminal Unit

Terminal Unit

Terminal Unit

Terminal Unit

Terminal Unit

Terminal Unit

Terminal Unit

Terminal Unit

Terminal Unit

Terminal Unit

C-DOT MBM-XL

BASE MODULE CENTRAL MODULE BASE MODULE

Administrative Processor Unit

Space Switch Control Unit

Space Switch Unit

Bus Termination Unit

Space Switch Unit

Bus Termination Unit

Terminal Unit

Terminal Unit

Terminal Unit

Terminal Unit

Terminal Unit

Terminal Unit

Base Processor Unit

Time Switch Unit

Terminal Unit

Terminal Unit

Base Processor Unit

Time Switch Unit

SUBSCRIBER FEATURESNumber Identification Service

Calling Line Identification Presentation(CLIP)Calling Line Identification Restriction(CLIR)Calling Line Identification Restriction Override(CLIRO)Malicious Call Identification(MCID)

SUBSCRIBER FEATURESCall Offering Supplementary ServicesCall Forwarding Unconditional(CFU)Call Forwarding Busy (CBF)Call Forwarding No Reply (CNFR) Call Completion ServicesCall WaitingCall Hold

SUBSCRIBER FEATURESMulti - Party ServicesThree Party ConferenceMulti Party Conference(Add-on Card)Miscellaneous ServicesHot Line(Timed)Hot Line (Without Time Out)Reminder Call/Alarm Services

SUBSCRIBER FEATURES

Subscriber Controlled Call Restriction ServicesIntrusion Barring ServiceDialling By Terminal Equipment NumberTrunk OfferingQueuing ServicePriority SubscriberDistinctive Ringing For Long Distance Calls

SYSTEM FEATURESSignalling, Routing And Charging FeaturesExchange Operation FeaturesExchange Maintenance FeaturesSoftware Upgradation & Patch AdministrationReconfiguration for Different Applications

PSUII

LCC/CCM

LCC/CCM

LCC/CCM

LCC/CCM

LCC/CCM

LCC/CCM

LCC/CCM

LCC/CCM

T

I

C

SPC/ISP

T

U

I

T

U

I

SPC/ISP

T

I

C

LCC/CCM

LCC/CCM

LCC/CCM

LCC/CCM

LCC/CCM

LCC/CCM

LCC/CCM

LCC/CCM

PSUII

25

24

23

22

21

20

19

18

17

16

15

14

13

12

11

10

987654321 26

ANALOG TERMINAL UNIT

*VACANT SLOT OF PSM/ESM FILLED BY CML CARD

BRL/PRL

BRL

BRL/PRL

BRL

BRL/PRL

BRL

BRL/PRL

ITC1

ICC1

IIC1

IIC0

ICC0

ITC0

BRL

BRL/PRL

BRL

BRL/PRL

BRL

BRL/PRL

BRL

BRL/PRL

PSUII

PSUII

25

24

23

22

21

20

19

18

17

16

15

14

13

12

11

10

987654321 26

INTEGRATED SERVICES DIGITAL TERMINAL UNIT

*VACANT SLOT OF PSM/ESM FILLED BY CML CARD

PSUII

PSUII

PSM/ESM

PSM/ESM

PSM/ESM

PSM/ESM

PSM/ESM

PSM/ESM

PSM/ESM

PSM/ESM

CMLAOO

CMLAOO

PSM/ESM

PSM/ESM

PSM/ESM

PSM/ESM

PSM/ESM

PSM/ESM

PSM/ESM

PSM/ESM

PSUII

PSUII

25

24

23

22

21

20

19

18

17

16

15

14

13

12

11

10

987654321 26

BUS TERMINATION UNIT

*VACANT SLOT OF PSM/ESM FILLED BY CML CARD

PSUII

PSUII

PSM/ESM

PSM/ESM

PSM/ESM

PSM/ESM

PSM/ESM

PSM/ESM

PSM/ESM

PSM/ESM

CMLAOO

CMLAOO

PSM/ESM

PSM/ESM

PSM/ESM

PSM/ESM

PSM/ESM

PSM/ESM

PSM/ESM

PSM/ESM

PSUII

PSUII

25

24

23

22

21

20

19

18

17

16

15

14

13

12

11

10

987654321 26

BUS TERMINATION UNIT

*VACANT SLOT OF PSM/ESM FILLED BY CML CARD

PSUII

PSUII

PSM/ESM

PSM/ESM

PSM/ESM

PSM/ESM

PSM/ESM

PSM/ESM

PSM/ESM

PSM/ESM

CMLAOO

CMLAOO

PSM/ESM

PSM/ESM

PSM/ESM

PSM/ESM

PSM/ESM

PSM/ESM

PSM/ESM

PSM/ESM

PSUII

PSUII

25

24

23

22

21

20

19

18

17

16

15

14

13

12

11

10

987654321 26

BUS TERMINATION UNIT

*VACANT SLOT OF PSM/ESM FILLED BY CML CARD

PSUII

PSUII

PSM/ESM

PSM/ESM

PSM/ESM

PSM/ESM

PSM/ESM

PSM/ESM

PSM/ESM

PSM/ESM

CMLAOO

CMLAOO

PSM/ESM

PSM/ESM

PSM/ESM

PSM/ESM

PSM/ESM

PSM/ESM

PSM/ESM

PSM/ESM

PSUII

PSUII

25

24

23

22

21

20

19

18

17

16

15

14

13

12

11

10

987654321 26

BUS TERMINATION UNIT

*VACANT SLOT OF PSM/ESM FILLED BY CML CARD

PSUII

PSUII

P

S

S

P

S

S

P

S

S

P

S

S

P

S

S

P

S

S

P

S

S

P

S

S

CMLAOO

CMLAOO

P

S

S

P

S

S

P

S

S

P

S

S

P

S

S

P

S

S

P

S

S

P

S

S

PSUII

PSUII

25

24

23

22

21

20

19

18

17

16

15

14

13

12

11

10

987654321 26

SPACE SWIYCH UNIT

*VACANT SLOT OF PSS FILLED BY CSL CARD

PSUII

PSUII

C

C

K

B

M

E

CMLAOO

C

B

X

N

S

C

HPC/BPC

CMLAOO

CMLAOO

HPC/BPC

N

S

C

C

B

X

CMLAOO

B

M

E

C

C

K

PSUII

PSUII

25

24

23

22

21

20

19

18

17

16

15

14

13

12

11

10

987654321 26

SPACE SWITCH CONTROLE UNIT

PSUII

PSUII

CMLAOO

CMLAOO

H

M

S

CMLAOO

CMLAOO

H

M

S

B

M

E

HPC/BPC

CMLAOO

CMLAOO

HPC/BPC

B

M

E

H

M

S

CMLAOO

CMLAOO

H

M

S

CMLAOO

CMLAOO

PSUII

PSUII

25

24

23

22

21

20

19

18

17

16

15

14

13

12

11

10

987654321 26

ADMN PROCESSOR UNIT

SIGNALLING UNIT MODULE

PSUII

PSUII

BME

SHM8

SHM7

SHM6

SHM5

HPC/BPC

TUC

TUI

TUI

TUC

HPC/BPC

SHM4

SHM3

SHM2

SHM1

BME

PSUII

PSUII

25

24

23

22

21

20

19

18

17

16

15

14

13

12

11

10

987654321 26

REMOTE SWITCH UNIT REMOTE PRODUCTSRemote Switch Unit(RSU)Remote Line Unit(RLU)Remote Line Concentrator(RLC)NEED FOR REMOTE SWITCH UNITSolution for Space for large exchangesReducing the cost on cables

REMOTE SWITCH UNIT REMOTE SWITCH UNIT FEATURESPower On InitializationDigital Trunk Link StatusCall Shifting During DTK FaultInitialization In Stand Alone ModeInitialization From RBMSA To Normal (RBM) Mode

REMOTE SWITCH UNIT REMOTE SWITCH UNIT FEATURESSupport For Trunks In RBMNumbering Scheme In RSUSupport For Different Area Code In RSU and Main ExchangeProvision To Block Local Calls Between Main Exchange and RSU If RSU have Different Area Code

REMOTE SWITCH UNIT REMOTE SWITCH UNIT FEATURESEmergency Services In RBMSA Mode

Charging For RBMLine To Line CallLine To Trunk CallsTrunk To Line Calls(I/C Terminating)Trunk To Trunk Calls

REMOTE SWITCH UNIT RSU RELATED COMMANDS

CRE-RBMSA-CONFIGDISPL-RBMSA-CONFIGMOD-RBM-XCODDISPL-RBM-XCODADD-DTK-RBMDISPL-RBM-DTKSMOD-SUB-CRGDISPL-SUB-CRG

C-DOT 256P AN-RAX and RLC FEATURES

FEATURESProvides front end termination for PSTN subscribersSupports maximum of 248 PSTN subscribersConnected to Local Exchange (LE) over one or two E1 links using standard V5.2 Protocol as per ITU-T specifications G.964 & G.965 and ETSI specifications 300-324 & 300-347.Provides First/Second Level of remotingProvides a transparent link between subscriber and Local ExchangeProvides Calling Line Identification Presentation (CLIP) on 2 ports of LCC cardProvides 16KHz Metering Pulse and Calling Line Identification Presentation (CLIP) on 2 ports of each CCM cardProvides Reversal on all 8 ports of CCM cardProvides Man Machine Interface (MMI) using VT 100 dumb

FEATURES

Password ProtectionRequires no air-conditioningLow Power ConsumptionLine Testing can be performed locallyTransparently supports all subscribers feature as supported by Local Exchange (LE)For any feature related enhancements, the S/W changes are to be done on Local Exchange (LE) only

(Contd.)

HARDWAREConsists of two controller cards

AN RAX Controller Card (ARC Card)AN RAX Interface Card (ARI Card)

ARC card supports 2 E1 links toward Local ExchangeBoth the cards form a security block alongwith respective SPC cardsRedundancy in Controller Cards8 port LCC/CCM cards for Subscriber InterfaceRTC card for testing of subscriber ports

256P RAX CARD FRAME CONFIGURATION

1 2 3 4 8765 13 14 15 161211109 21 22 23 2420191817

PSU

TC

CPS

PSU

USP

USP

FNC R

TC

SLAVEFRAME

MASTERFRAME

TC

TC

TC

TC

TC T

C

TC C

TCT

CT

CT

CT

CT

CT

Ø

Ø

RSC C

SR

1

1

SPC

32 CH. PCMTG 5 6TG {COPY Ø 1COPY{ TG 7 TG 8

Ø 1

Ø 1

TC

TC

CPS

1

1

RSCC

SR

Ø

Ø

SPC

FMR

TAR

Ø Ø

RAP

1

RAP

1

RAT

RMF1

TG 1 2TG TG 43TG

TC :

RAP :RAT :

RTC :RSC :

SPC / ISP:

RMF :

LCC/TWT/EMF/RDT/CCM CARD

RAX ADMINISTRATIVE PROCESSORRAX ANNOUNCEMENT AND TONE CARD

RAX TERMINAL TEST CARDRAX SWITCH CONTROLLER CARD

SIGNALLING PROCESSOR CARD / INTEGRATED SIGNALLING PROCESSING CARD

RAX MULTI FREQ. CARD

CT

CT

CT

CT

25 26

CT

CT T

CTC

TC/

SLAVESLAVE

PSU-I : POWER SUPPLY UNIT-ICONFERENCE CARDCNF :

{ {COPY ØMASTER

COPY 1MASTER

Ø

/CT

/CT

/CDR

/SDR

- - - -

- -

CARD DETAILS :

RAX WLL CONTROLLER CARDRWC:

WR

C/

C

C

RW

/T

I

I I

I

/PSI

/PSI

P

IS

/

ISP/

\DESIGN\ANRX-UM\Argu-cf

256P AN-RAX CARD FRAME CONFIGURATION

1 2 3 4 8765 13 14 15 161211109 21 22 23 2420191817

PSU

TC

CPS

PSU

USP

USPR

TC

SLAVEFRAME

MASTERFRAME

TC

TC

TC

TC

TC

TC C

TCT

CT

CT

CT

CT

CT

Ø

Ø

ARI I

RA

1

1

SPC

32 CH. PCMTG 5 6TG {COPY Ø 1COPY{ TG 7 TG 8

Ø 1

Ø 1

TC

TC

CPS

1

1

ARCC

RA

Ø

Ø

SPC

TG 1 2TG TG 43TG

TC :

RTC :SPC / ISP:

LCC/CCM CARD

RAX TERMINAL TEST CARDSIGNALLING PROCESSOR CARD / INTEGRATED SIGNALLING PROCESSING CARD

CT

CT

CT

CT

25 26

CT

CT T

CTC

SLAVESLAVE

PSU-I : POWER SUPPLY UNIT-I

AN-RAX CONTROLLER CARDARC :

{ {COPY ØMASTER

COPY 1MASTER

- - - -

- -

CARD DETAILS :

I

I I

I

/PSI

/PSI

P

IS

/

ISP/

\DESIGN\ANRX-UM\Argu-cf

AN-RAX INTERFACE CARDARI :

CT

CT

CT T

CTC

CT

CT

CONNECTIVITY TO NETWORK

NETWORK

LocalExchange

C-DOTMBMOR

OtherMNC

Exchanges

DEC/R2/#7 V5.2 Interface

PrimaryLink

SecondaryLink

AN-RAX 248 Subscribers

RS232

ConsoleVT-100

DIFFERENCE BETWEENC-DOT RSU AND C-DOT AN-RAX

C-DOT RSU C-DOT AN-RAX

• First Level of Remoting • First/Second Level ofRemoting

• Connected to LE throughProprietory Protocol

• Connected to LE throughStandard V5 protocol

• In standalone mode it performsthe various call processing &Billing functions

• In standalone mode it onlyfeeds the tone/ announcementto the subscriber

REMOTE LINE CONCENTRATOR(RLC) AS ACCESS NETWORK

FEATURES

Provides front end terminationSupports maximum of 120 PSTN subscribersSupports maximum of 56 ISDN BRA subscribersCombination of PSTN & ISDN BRA subscribers. (Compatible motherboard)Connected to Local Exchange (LE) over two E1 linksProvides second level of remotingProvides a transparent link between subscribers and local exchange

FEATURESProvides 16KHz metering pulse, Reversal and Calling LineIdentification (CLI) on all ports.Provides Man Machine Interface (MMI)Password protectionWall mountable (light weight)Require no air conditioningLow power consumptionWill provide HDSL connectivity in futureCompact in Size (19” packaging)Line testing can be performed locally

C-DOT RLC CARD CAGE

MPU : MUX Power Unit to Provide Ring and Voltages

MTC : MUX Tester Card for Line Card Testing and to Provide announcement

MLC : MUX Line Card

MCS : MUX Control and Signaling Card ; E1 Link Termination and V5 Protocol Software

DIFFERENCE BETWEENRSU AND RLC

RSU RLC

• First level of Remoting • Second level Remoting

• Connected to LEthrough proprietoryprotocol

• Connected to LEthrough Standard V5protocol

• In 'Stand Alone' mode itperforms the variousCall Processing & BillingFunctions

• In 'Stand Alone' mode,it only feeds the tone tosubscribers