Contract Part C3.6 Part C3 Scope of Work Returnable Technical Schedules Reference No. BFN 4/2017
AIRPORTS COMPANY SOUTH AFRICA BRAM FISCHER INTERNATIONAL AIRPORT CONTRACT NO: BFN 4/2017 CONSTRUCTION OF A PHOTOVOLTAIC PLANT
C3: Scope of Work
C3.6: Returnable Technical Schedules
Note that incomplete completion of these schedules may make the technical evaluation of the tender impossible and may result in disqualification of the tender
Page C3.6 - 2 of 23
Contract Part C3.6 Part C3 Scope of Work Returnable Technical Schedules Reference No. BFN 4/2017
Contents
Page
1. Track record ...................................................................................................... 4
2. Reference projects ........................................................................................... 5
3. Solar PV array structure .................................................................................. 6
4. Array layout drawing ........................................................................................ 7
5. Yield reports ...................................................................................................... 8
6. Single line diagram ........................................................................................... 9
7. PV Module data ............................................................................................... 10
8. Inverter data .................................................................................................... 12
9. SCADA ............................................................................................................. 15
10. Cables .............................................................................................................. 16
11. DC Connectors ............................................................................................... 17
12. LV Circuit Breakers ........................................................................................ 18
13. Minisub ............................................................................................................ 19
14. Total annual energy yield at Inverter ............................................................ 20
15. Total annual energy yield a Transformer...................................................... 21
16. Total annual energy yield a POC ................................................................... 22
17. Performance ratio guarantee ......................................................................... 23
18. Minimum warranties ....................................................................................... 23
Page C3.6 - 3 of 23
Contract Part C3.6 Part C3 Scope of Work Returnable Technical Schedules Reference No. BFN 4/2017
Definitions
The following definitions apply to the schedule columns of this specification: SCHEDULE A: Particulars of minimum requirements of the Employer, where indicated. SCHEDULE B: Guarantees and technical particulars of similar or equal equipment offered by Tenderer. Where insufficient space is provided by Schedule B, particulars must be furnished on separate sheets clearly marked with the number of the item referred to in Schedule A. The tender must clearly state all deviations (if any) in the Deviation Schedule and in Schedule B (if applicable). No tender for any apparatus will be accepted unless the schedules below are fully completed.
Page C3.6 - 4 of 23
Contract Part C3.6 Part C3 Scope of Work Returnable Technical Schedules Reference No. BFN 4/2017
1. Track record
(Must be of similar size & scope)
Year Installed PV capacity (kWp/MWp)
Project Value: Description & reference: Project Duration (months):
Page C3.6 - 5 of 23
Contract Part C3.6 Part C3 Scope of Work Returnable Technical Schedules Reference No. BFN 4/2017
2. Reference Projects
(2 required per category, as set out hereunder)
Reference project 1 Equal to or greater than 500kWp but less than or equal to 1MWp
Reference Company Name:
Address:
Telephone:
Email:
Project Director:
Panel and inverter technology:
Project Value:
Project Duration:
Project Location:
Project Manager:
Reference project 2 Equal to or greater than 1MWp
Reference Company Name:
Address:
Telephone:
Email:
Project Director:
Panel and inverter technology:
Project Value:
Project Duration:
Project Location:
Project Manager:
Page C3.6 - 6 of 23
Contract Part C3.6 Part C3 Scope of Work Returnable Technical Schedules Reference No. BFN 4/2017
3. Solar PV array structure
PARAMETER SCHEDULE B
Structural Shape (tubular /Angular steel/ Al)
Corrosion protection and UV protection
Wind Stability or maximum wind speed (km/h)
Static and dynamic assumptions
Weight per m²
Installation method and anchoring interface
Modular or standalone system
Durability and Lifespan in years
Inclination to the horizontal
Other
Page C3.6 - 7 of 23
Contract Part C3.6 Part C3 Scope of Work Returnable Technical Schedules Reference No. BFN 4/2017
4. Array layout drawing
(Layout drawing to be submitted by Tenderer)
Page C3.6 - 8 of 23
Contract Part C3.6 Part C3 Scope of Work Returnable Technical Schedules Reference No. BFN 4/2017
5. Yield reports
(Yield reports to be submitted by Tenderer)
Page C3.6 - 9 of 23
Contract Part C3.6 Part C3 Scope of Work Returnable Technical Schedules Reference No. BFN 4/2017
6. Single line diagram (high level)
(SLD to be submitted by Tenderer)
Page C3.6 - 10 of 23
Contract Part C3.6 Part C3 Scope of Work Returnable Technical Schedules Reference No. BFN 4/2017
7. PV Module data (1of2)
PARAMETER SCHEDULE A SCHEDULE B
Manufacturer and Model:
Manufacturer SolarWorld
Model Sunmodule Protect 250
Country of manufacture Freiburg Germany
Class (IEC 61730 or equivalent) IEC 61730 and IEC 61215
Electrical Characteristics:
Peak Power (PMPP) ≥ 250 Wp
Open Circuit Voltage (VOC) 37.6
Short Circuit Current (ISC) 8.81
Maximum Power Voltage (VMPP) 30.5
Maximum Power Current (IMPP) 8.27
Maximum System Voltage 1000
Working Temperature range -40 °C to +85 °C
Mechanical Characteristics:
Dimension (LxWxD) 1675x1001x31mm
Weight 21.2kg
Connector type and manufacture MC4 - German
Junction Box type and manufacture SolarWorld IP65
Cell (p-Csi , mono Csi, Thin film type
and size Poly Crystaline
No of Cells and connections per
panel 60
Temperature/Coefficients:
Temperature Coefficient VOC -0.31 %/K
Temperature Coefficient ISC 0.051 %/K
Temperature Coefficient PMPP -0.41 %/K
Quality Assurance and Standard:
IEC/ISO/SABS Certification SGS/TUV/CE/IEC/SAC/VDE/GS
Product Warranty/Guarantee 10 Years
Performance warranty/guarantee
(include power degradation graph as
a function of time for 25 years’ year
period. Illustrate start % and annual
rate % and end %
30-year linear performance guarantee: a maximum degradation of just 0.35 % p. a. provides guaranteed module performance of 90 % after 21 years, and 86.85 % after 30 years.
Reinsurance and underwriter Incorporated in SolarWorld financial model
Page C3.6 - 11 of 23
Contract Part C3.6 Part C3 Scope of Work Returnable Technical Schedules Reference No. BFN 4/2017
PV Module data (2of2)
STC:
STC and NOCT 25 °C and 46 °C
STC used 1000W/m², 25°C, AM 1.5
Peak power (W) (STC) 250Wp -0% +5%
Rated voltage (V) (MPP STC) 30.5
Rated current (A) (MPP STC) 8.27
Open circuit voltage (V) (STC) 37.6
Short circuit current (A) (STC) 8.27
Maximum system voltage 1000
Temperature Coefficient (max power)
(%/°C) -0.41
Cables (type & details)
4mm² Compact double insulated, electron-beam cross-linked, halogen free photovoltaic wire with sunlight resistant integrated jacket. Single conductor, flame retardant insulation with reduced diameter. (TÜV Norm 2 PfG 1169 08.2007 PV1-F)
Connectors MC4 - German
Ingress Protection Rating
IP69k - see included Amonia and sand resistance/ salt mist corrotion tests and impact testing. In the hail impact test, we replicate a natural hailstorm by dropping a 500-gram, 25-millimeter diameter steel ball onto the solar module from a height of four meters. This is repeated up to 20 times in the same place and on at least eleven different points of impact. The IEC only specifies a standard weight of 7.53 grams per steel ball.
Frame construction and colour Aluminium Silver/Black
Warranty (product) 10 years
Warranty (90% power) 21 years
Page C3.6 - 12 of 23
Contract Part C3.6 Part C3 Scope of Work Returnable Technical Schedules Reference No. BFN 4/2017
8. Inverter data (1of3)
PARAMETER SCHEDULE A SCHEDULE B
Manufacturer and Model:
Manufacturer SMA
Model STP17000-TL10
Country of manufacture Germany
Electrical Characteristics:
Recommended power from PV array
(kWp) 17
Output power from inverter and
graph of efficiency 98.20%
AC nominal voltage 3 / N / PE, 230 V / 400 V range 160 V – 280 V
Nominal frequency 50, 60 Hz; –6 Hz, +5 Hz
Maximum line current 24.6 A
AC current distortion (% THD) L1- 0.99 ; L2 - 1.01 ; L3 - 0.94
Open circuit maximum voltage 1000
Inverter efficiency, derating % /Deg C
over 50 Deg C ±1.5%
Single phase or three phase -
Maximum power (DC) 17410W
Range of PV input voltage MPPT
(DC) 400 V – 800 V
Nominal voltage (DC) 600V
Start-up voltage (DC) 188 V
Maximum module voltage (DC) 1000 V
Module current range (DC) String A: 33 A, String B: 11 String A / 33 A
Nominal current (DC) N/A
Minimum nominal power rating (AC) 17000
Nominal voltage (AC) 3 / N / PE, 230 V / 400 V range 160 V – 280 V
Nominal current (AC) 24.6A
Current range (AC) 0 - 24.6A
Frequency range 50, 60 Hz; –6 Hz, +5 Hz
Page C3.6 - 13 of 23
Contract Part C3.6 Part C3 Scope of Work Returnable Technical Schedules Reference No. BFN 4/2017
Inverter data (2of3)
Power factor 0.8 leading to 0.8 lagging (Test value at rated power >0.99)
Quantity and type of DC connectors Sunclix : 5 x strings A and 1 x string B
Operating temperature –25 °C to +60 °C
Minimum efficiency 20% to nominal power (%)
See graph on Data Sheet
Total Harmonic Distortion (%) L1- 0.99 ; L2 - 1.01 ; L3 - 0.94
Standby power consumption (W) 1W
Night-time power consumption (W) 1W
Mechanical Characteristics:
Dimension (W x H x D) 665 / 690 / 265
Weight 65
IP rating Electronics protection rating IP65 / connection area IP54
Operating temperature –25 °C to +60 °C
Cooling system
OptiCool - The innovative cooling system OptiCool® actively cools the inverter, meaning that the rpm-regulated fan motor is activated when the sensors installed in various places on the device measure temperature increases. OptiCool® is made up of two separate ventilation circuits. As fresh air from outside is drawn in to cool heat-producing components, circulating warm air is cooled down in an internal ventilation circuit on the inside of the inverter. The heat exchanger used in this process is operated by fresh-air supply.
Ventilation OptiCool with Fan
Ingress Protection Rating Electronics protection rating IP65 / connection area IP54
Page C3.6 - 14 of 23
Contract Part C3.6 Part C3 Scope of Work Returnable Technical Schedules Reference No. BFN 4/2017
Inverter data (3of3)
Safety
In built protection functions
DC reverse-polarity protection reverse current protection ESS switch-disconnector AC short circuit protection Ground fault monitoring Galvanically isolated all-pole sensitive fault current monitoring unit DC overvoltage protector type II String failure detection Protection class I overvoltage category III
Self – monitoring system and alarms > 90 Events See manual 11.1 Event Messages 11.2 Error messages
Quality Assurance:
IEC/ISO/SABS Certification
Yes Certificates and permits (more available on request) CE, VDE 0126-1-1, Enel-GUIDA*, G83/1-1, PPC, AS4777, EN 50438**, C10/C11, IEC 61727*
Grid Guard country Codes and
conforms to NRS -097
VDE-AR-N4105 VDE 0126-1-1 AS4777 C10/11 PPDS GBT19939-2005 UTE C15-712-1 PPC NRS 97-2-1 EN50438 RD661/2007 IEC 61727 G59/2 CEI 0-21 BDEW 2008 RD1699:2011 SI4777
Product warranty/guarantee Warranty 5 years
Performance warranty/guarantee 5 years
Extension of warranty optional 10 / 15 / 20 / 25 years
Local technical support and spares
centre Yes
Special installation transport
requirements Basic
Page C3.6 - 15 of 23
Contract Part C3.6 Part C3 Scope of Work Returnable Technical Schedules Reference No. BFN 4/2017
9. Plant SCADA
PARAMETER SCHEDULE B
Manufacturer and Model
Array Voltage – VDC (V)
Grid voltage – VAC (V)
Array Current – IDC (A)
Grid (injected) current – IAC (A)
Array power – PDC (W)
kWh, kWAC peak per day
Module temperature – T module (°C) ( where
mounted )
Ambient temperature – Tamb (°C)
Solar Radiation – (W/m²)
Alarms and alarm set pint management
Wind speed
precipitation
Data logging capability with a user friendly
GUI and automated report generation
capability
Histogram data format and size
Communications interface (Ethernet, Internet,
GSM/GPRS)
Plant / machine interface ( fiber / copper )
and protocol ( Bus, RS 485)
SMS alerts
Local storage and redundant storage
Licence fees and updates
Local support
Page C3.6 - 16 of 23
Contract Part C3.6 Part C3 Scope of Work Returnable Technical Schedules Reference No. BFN 4/2017
10. Cables
Low voltage cables
PARAMETER SCHEDULE A SCHEDULE B
Manufacturer ABERDARE and/or Helukabel
Type 600/1000 V PVC Cu armoured
Single or multicore Multicore Insulation material PVC Sheath material PVC Sheath colour/s - Standards achieved SANS 1507
Medium voltage cables
PARAMETER SCHEDULE A SCHEDULE B
Manufacturer ABERDARE
Type 11 kV XLPE armoured Vultex Type A
Single or multicore Multicore
Insulation material Oil impregnated paper
Sheath material Lead, PVC served
Sheath colour/s -
Standards achieved SANS 97
DC Cables
PARAMETER SCHEDULE A SCHEDULE B
Manufacturer ABERDARE
Type Solardac
Rated voltage (Volts) 1500 V DC, 600/1000 V AC
Single or multicore Single
Temp. rating -15ºC to 90ºC
Insulation material Polyolefin
Sheath material Polyolefin
Sheath colour/s Black
Inner sheath colour(s) -
Standards achieved SANS 1507
Page C3.6 - 17 of 23
Contract Part C3.6 Part C3 Scope of Work Returnable Technical Schedules Reference No. BFN 4/2017
11. DC Cable connectors
PARAMETER SCHEDULE A SCHEDULE B
Manufacturer Multi Connect
Type MC4 Multilam Technology (multiconnect)
Rated voltage (Volts) 1000V DC
kA rating More than 2kA
Thermal rating Up to 350 °C
Mechanical contact durability Up to 1 million mating cycles
Page C3.6 - 18 of 23
Contract Part C3.6 Part C3 Scope of Work Returnable Technical Schedules Reference No. BFN 4/2017
12. LV Circuit breakers
AC
PARAMETER SCHEDULE B
Manufacturer
Model
Fault rating
DC
PARAMETER SCHEDULE B
Manufacturer
Model
Fault rating
FUSES
PARAMETER SCHEDULE B
Manufacturer
Model
Fault rating
Page C3.6 - 19 of 23
Contract Part C3.6 Part C3 Scope of Work Returnable Technical Schedules Reference No. BFN 4/2017
13. Minisub
DESCRIPTION UNIT SCHEDULE A SCHEDULE B
Manufacturer Powertech-
Metal enclosed 3CR12 – 2.0mm
Paint finishing Coastal spec
Colour Avocado Green
Doors Protruding with concealed
hinges
Lock mechanism 3 point with Allen key bolt
RMU ABB Safe Ring CCV
MV Surge arrestors RSTI-66SA1210
MV Elbow adapter RSTI-L-5651
RMU MV boot RCAB 4120
Rated output kVA 800
Primary rated voltage kV 11
Secondary rated voltage V 400 (no load)
MV Taps ±2.5% and ±5%
Vector group Dyn 11
Protection:
-Relay
RJ603 with remote trip input option
-Thermometer Set at 105°C
-Shunt trip coil and relay included
-Earth fault indicator With control unit & split CT’s
Losses:
-No load W -
-Full load W -
Insulation level (BIL) kV -
Core or shell type core
High voltage fuse rating A N/A
Main LV switch disconnector:
-Type -
-Circuit breaking capacity kA -
-Current trip rating A -
-Voltage V 440
Bulk consumption meter:
Type
Elster A1700 with KoCos modem
Test block 13 way
Current transformer 1200/5A 20 VA Class 0.5A
Page C3.6 - 20 of 23
Contract Part C3.6 Part C3 Scope of Work Returnable Technical Schedules Reference No. BFN 4/2017
14. Total guaranteed annual energy yield at inverter
P50 P90 Annual degradation
Year kWh kWh %
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
Cumulative Total
Page C3.6 - 21 of 23
Contract Part C3.6 Part C3 Scope of Work Returnable Technical Schedules Reference No. BFN 4/2017
15. Total guaranteed annual energy yield at transformer
P50 P90 Annual degradation
Year kWh kWh %
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
Cumulative Total
Page C3.6 - 22 of 23
Contract Part C3.6 Part C3 Scope of Work Returnable Technical Schedules Reference No. BFN 4/2017
16. Total guaranteed annual energy yield at POC
P50 P90 Annual degradation
Year kWh kWh %
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
Cumulative Total
Page C3.6 - 23 of 23
Contract Part C3.6 Part C3 Scope of Work Returnable Technical Schedules Reference No. BFN 4/2017
17. Performance ratio guarantee
The performance ratio (PR) is defined according to the standard IEC 61724:
r
f
Y
YPR
Minimum acceptable values:
DESCRIPTION SCHEDULE A SCHEDULE B
Plant availability losses allowed 0.5%
Practical Completion 79%
Guaranteed long term 75%
18. Minimum warranties
Minimum acceptable values:
DESCRIPTION SCHEDULE A SCHEDULE B
Civil works 1year
AC cables 1 year
MV switchgear 2 years
Mini-substation 2 year
Inverters 5 years
PV Module substructure (steel) 5 years
PV Module substructure (Al) 10 years
DC Cables 1 year
PV Modules (product) 10 years
PV Modules (power output) 25 years
Control and monitoring system 2 years
Complete plant beyond the POC years
Note: that warranties from the main suppliers shall be transferred to the Employer on 100% payment of the
relevant item.
Extended warranties offered (please provide details and implication on cost for Employer):
DESCRIPTION SCHEDULE B Cost implication
Inverters
PV Modules (product)