calibration iso/iec 17025:2017 truecal

45
TRUECAL has been assessed and accredited in accordance with the standard ISO/IEC 17025:2017 ''General Requirements for the Competence of Testing & Calibration Laboratories'' for its facilities at PLOT NO 18, FIRST FLOOR, SANTOSHIMA COLONY, SECUNDERABAD, TELANGANA, INDIA in the field of CALIBRATION Certificate Number: CC-2230 Issue Date: 14/05/2019 Valid Until: 13/05/2021 This certificate remains valid for the Scope of Accreditation as specified in the annexure subject to continued satisfactory compliance to the above standard & the relevant requirements of NABL. (To see the scope of accreditation of this laboratory, you may also visit NABL website www.nabl-india.org) Signed for and on behalf of NABL N. Venkateswaran Chief Executive Officer

Upload: others

Post on 26-Feb-2022

25 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: CALIBRATION ISO/IEC 17025:2017 TRUECAL

TRUECALhas been assessed and accredited in accordance with the standard

ISO/IEC 17025:2017''General Requirements for the Competence of Testing &

Calibration Laboratories''for its facilities at

PLOT NO 18, FIRST FLOOR, SANTOSHIMA COLONY, SECUNDERABAD, TELANGANA, INDIA

in the field of

CALIBRATIONCertificate Number: CC-2230

Issue Date: 14/05/2019 Valid Until: 13/05/2021

This certificate remains valid for the Scope of Accreditation as specified in the annexure subject to continuedsatisfactory compliance to the above standard & the relevant requirements of NABL.

(To see the scope of accreditation of this laboratory, you may also visit NABL website www.nabl-india.org)

Signed for and on behalf of NABL

N. VenkateswaranChief Executive Officer

Page 2: CALIBRATION ISO/IEC 17025:2017 TRUECAL

S.No Discipline / Group Quantity Measured/Instrument

Range / Frequency * CalibrationMeasurementCapability(±)

Remarks

Permanent Facility

1 ELECTRO-TECHNICAL-ALTERNATINGCURRENT (< 1 GHZ)(Source)

AC Current @ 50 Hz to1 kHz

1 A to 20 A 0.17% to 0.20% Using Calibrator FlukeMPC 5522A by Directmethod

2 ELECTRO-TECHNICAL-ALTERNATINGCURRENT (< 1 GHZ)(Source)

AC Current 50 Hz 20 A to 1000 A 3.19% to 0.7% Using Calibrator FlukeMPC 5522A with 50turns current Coil

3 ELECTRO-TECHNICAL-ALTERNATINGCURRENT (< 1 GHZ)(Source)

AC Current 50 Hz to 1kHz

3 mA to 1 A 0.15% to 0.07% Using Calibrator FlukeMPC 5522A by Directmethod

4 ELECTRO-TECHNICAL-ALTERNATINGCURRENT (< 1 GHZ)(Source)

AC Current 50 Hz to 1kHz

30 µA to 3 mA 1.07% to 0.15% Using Calibrator FlukeMPC 5522A by Directmethod

5 ELECTRO-TECHNICAL- DIRECTCURRENT (Measure)

DC Current 1 A to 10 A 0.086% to 0.193% Using Fluke 8846A61/2 Digital DMM byDirect Method

6 ELECTRO-TECHNICAL- DIRECTCURRENT (Measure)

DC Current 1 mA to 100 mA 0.076% to 0.067% Using Fluke 8846A61/2 Digital DMM byDirect Method

7 ELECTRO-TECHNICAL- DIRECTCURRENT (Measure)

DC Current 10 µA to 1 mA 0.404% to 0.076% Using Fluke 8846A61/2 Digital DMM byDirect Method

This is annexure to 'Certificate of Accreditation' and does not require any signature.

Laboratory Name TRUECAL, PLOT NO 18, FIRST FLOOR, SANTOSHIMA COLONY,SECUNDERABAD, TELANGANA, INDIA

Accreditation Standard ISO/IEC 17025:2017

Certificate Number CC-2230 Page No. : 1 / 44

Validity 14/05/2019 to 13/05/2021 Last Amended on 23/05/2019

Page 3: CALIBRATION ISO/IEC 17025:2017 TRUECAL

S.No Discipline / Group Quantity Measured/Instrument

Range / Frequency * CalibrationMeasurementCapability(±)

Remarks

8 ELECTRO-TECHNICAL- DIRECTCURRENT (Measure)

DC Current 10 A to 800 A 0.94% to 1.38% Using Shunt with DMM

9 ELECTRO-TECHNICAL- DIRECTCURRENT (Measure)

DC Current 100 mA to 1 A 0.067% to 0.086% Using Fluke 8846A61/2 Digital DMM byDirect Method

10 ELECTRO-TECHNICAL- DIRECTCURRENT (Source)

DC Current 1 A to 20 A 0.064% to 0.12% Using Fluke MPC5522A by DirectMethod

11 ELECTRO-TECHNICAL- DIRECTCURRENT (Source)

DC Current 10 µA to 100 µA 0.25% to 0.043% Using Fluke MPC5522A by DirectMethod

12 ELECTRO-TECHNICAL- DIRECTCURRENT (Source)

DC Current 100 µA to 100 mA 0.043% to 0.028% Using Fluke MPC5522A by DirectMethod

13 ELECTRO-TECHNICAL- DIRECTCURRENT (Source)

DC Current 100 A to 1000 A 0.87% to 0.7% Using Fluke MPC5522A with 50 TurnsCurrent Coil

14 ELECTRO-TECHNICAL- DIRECTCURRENT (Source)

DC Current 100 mA to 1 A 0.028% to 0.064% Using Fluke MPC5522A by DirectMethod

15 ELECTRO-TECHNICAL- DIRECTCURRENT (Source)

DC Current 20 A to 100 A 0.12% to 0.87% Using Fluke MPC5522A with 50 turnsCurrent Coil

16 ELECTRO-TECHNICAL-ELECTRICALEQUIPMENT(Measure)

AC Current @ 10 Hz to5 kHz

1 A to 10 A 0.47% Using Fluke 8846A 61/2 DMM by DirectMethod

This is annexure to 'Certificate of Accreditation' and does not require any signature.

Laboratory Name TRUECAL, PLOT NO 18, FIRST FLOOR, SANTOSHIMA COLONY,SECUNDERABAD, TELANGANA, INDIA

Accreditation Standard ISO/IEC 17025:2017

Certificate Number CC-2230 Page No. : 2 / 44

Validity 14/05/2019 to 13/05/2021 Last Amended on 23/05/2019

Page 4: CALIBRATION ISO/IEC 17025:2017 TRUECAL

S.No Discipline / Group Quantity Measured/Instrument

Range / Frequency * CalibrationMeasurementCapability(±)

Remarks

17 ELECTRO-TECHNICAL-ELECTRICALEQUIPMENT(Measure)

AC Current @ 10 Hz to5 kHz

1 mA to 100 mA 0.73% to 0.57% Using 8846A 6 1/2DMM by Direct Method

18 ELECTRO-TECHNICAL-ELECTRICALEQUIPMENT(Measure)

AC Current @ 10 Hz to5 kHz

100 mA to 1 A 0.57% Using Fluke 8846A 61/2 DMM by DirectMethod

19 ELECTRO-TECHNICAL-ELECTRICALEQUIPMENT(Measure)

AC Current @ 10 Hz to5 kHz

30 µA to 1 mA 0.73% to 0.57% Using Fluke 8846A 61/2 DMM by DirectMethod

20 ELECTRO-TECHNICAL-ELECTRICALEQUIPMENT(Measure)

AC Current @ 50 Hz 10 A to 20 A 0.82% Using Shunt with DMM

21 ELECTRO-TECHNICAL-ELECTRICALEQUIPMENT(Measure)

AC Voltage @ 10Hz to20 kHz

1 V to 100 V 0.14% to 0.12% Using Fluke 8846A 61/2 DMM by DirectMethod

22 ELECTRO-TECHNICAL-ELECTRICALEQUIPMENT(Measure)

AC Voltage @ 10Hz to20 kHz

100 mV to 1 V 0.2% to 0.14% Using Fluke 8846A 61/2 DMM by DirectMethod

This is annexure to 'Certificate of Accreditation' and does not require any signature.

Laboratory Name TRUECAL, PLOT NO 18, FIRST FLOOR, SANTOSHIMA COLONY,SECUNDERABAD, TELANGANA, INDIA

Accreditation Standard ISO/IEC 17025:2017

Certificate Number CC-2230 Page No. : 3 / 44

Validity 14/05/2019 to 13/05/2021 Last Amended on 23/05/2019

Page 5: CALIBRATION ISO/IEC 17025:2017 TRUECAL

S.No Discipline / Group Quantity Measured/Instrument

Range / Frequency * CalibrationMeasurementCapability(±)

Remarks

23 ELECTRO-TECHNICAL-ELECTRICALEQUIPMENT(Measure)

AC Voltage @ 10Hz to20 kHz

100 V to 1000 V 0.1% Using Fluke 8846 A 61/2 DMM by DirectMethod

24 ELECTRO-TECHNICAL-ELECTRICALEQUIPMENT(Measure)

AC Voltage @ 10Hz to20 kHz

3 mV to 100 mV 1.9% Usign Fluke 8846A 61/2 DMM by DirectMethod

25 ELECTRO-TECHNICAL-ELECTRICALEQUIPMENT(Measure)

AC Voltage @ 50 Hz 1 kV to 28 kV 3.3% Using Fluke HV PRobe80K 40 with DMM byDirect Method

26 ELECTRO-TECHNICAL-ELECTRICALEQUIPMENT(Measure)

Capacitance 100 Hz 1 µF to 100 µF 0.9% to 0.8% Using LCR Meter byDirect/Comparisonmethod.

27 ELECTRO-TECHNICAL-ELECTRICALEQUIPMENT(Measure)

Capacitance 100 Hz 100 uF to 100 mF 0.8% to 1.2% Using LCR Meter byDirect/Comparisonmethod.

28 ELECTRO-TECHNICAL-ELECTRICALEQUIPMENT(Measure)

Capacitance 1KHz 10 nF to 100 nF 0.7% to 0.6% Using LCR Meter byDirect/Comparisonmethod.

This is annexure to 'Certificate of Accreditation' and does not require any signature.

Laboratory Name TRUECAL, PLOT NO 18, FIRST FLOOR, SANTOSHIMA COLONY,SECUNDERABAD, TELANGANA, INDIA

Accreditation Standard ISO/IEC 17025:2017

Certificate Number CC-2230 Page No. : 4 / 44

Validity 14/05/2019 to 13/05/2021 Last Amended on 23/05/2019

Page 6: CALIBRATION ISO/IEC 17025:2017 TRUECAL

S.No Discipline / Group Quantity Measured/Instrument

Range / Frequency * CalibrationMeasurementCapability(±)

Remarks

29 ELECTRO-TECHNICAL-ELECTRICALEQUIPMENT(Measure)

Capacitance 1KHz 100 nF to 1 µF 0.8% Using LCR meter byDirect/comparisonmethod.

30 ELECTRO-TECHNICAL-ELECTRICALEQUIPMENT(Measure)

Capacitance 1KHz 100 pF to 10 nF 0.75% to 0.7% Using LCR Meter byDirect/ComparisonMethod

31 ELECTRO-TECHNICAL-ELECTRICALEQUIPMENT(Measure)

DC Voltage 1 kV to 40 kV 1.3% to 2.38% Using Fluke HV Probe80K 40 with DMM byDirect Method

32 ELECTRO-TECHNICAL-ELECTRICALEQUIPMENT(Measure)

DC Voltage 1 mV to 1 V 0.47% to 0.004% Using Fluke 8646A61/2 Digit DMM byDirect Methord

33 ELECTRO-TECHNICAL-ELECTRICALEQUIPMENT(Measure)

DC Voltage 1 V to 10 V 0.004% Using Fluke 8846A61/2 Digital DMM byDirect Method

34 ELECTRO-TECHNICAL-ELECTRICALEQUIPMENT(Measure)

DC Voltage 10 V to 100 V 0.004% to 0.0063% Using Fluke 8846A61/2 Digital DMM byDirect Method

This is annexure to 'Certificate of Accreditation' and does not require any signature.

Laboratory Name TRUECAL, PLOT NO 18, FIRST FLOOR, SANTOSHIMA COLONY,SECUNDERABAD, TELANGANA, INDIA

Accreditation Standard ISO/IEC 17025:2017

Certificate Number CC-2230 Page No. : 5 / 44

Validity 14/05/2019 to 13/05/2021 Last Amended on 23/05/2019

Page 7: CALIBRATION ISO/IEC 17025:2017 TRUECAL

S.No Discipline / Group Quantity Measured/Instrument

Range / Frequency * CalibrationMeasurementCapability(±)

Remarks

35 ELECTRO-TECHNICAL-ELECTRICALEQUIPMENT(Measure)

DC Voltage 100 V to 1000 V 0.0064% Using Fluke 8846A61/2 Digital DMM byDirect Method

36 ELECTRO-TECHNICAL-ELECTRICALEQUIPMENT(Measure)

Frequency 1 MHz to 1 GHz 0.0015% Using Counter, EZ FC-7150 V by DirectMethod

37 ELECTRO-TECHNICAL-ELECTRICALEQUIPMENT(Measure)

Frequency 3 Hz to 1 MHz 0.0035% to 0.0012% Using Counter, EZ FC--7150 V by DirectMethod

38 ELECTRO-TECHNICAL-ELECTRICALEQUIPMENT(Measure)

Inductance 1KHz 10 mH to 10 H 0.5% to 1.22% Using Source with LCRMeter byDirect/Comparisonmethod

39 ELECTRO-TECHNICAL-ELECTRICALEQUIPMENT(Measure)

Inductance 1KHz 100 uH to 10 mH 0.91% to 0.504% Using Source with LCRMeter byDirect/Comparisonmethod.

40 ELECTRO-TECHNICAL-ELECTRICALEQUIPMENT(Measure)

Resistance 1 mohm to 1 ohm 0.64% to 0.42% Using micro ohm meterby direct andcomparison method

This is annexure to 'Certificate of Accreditation' and does not require any signature.

Laboratory Name TRUECAL, PLOT NO 18, FIRST FLOOR, SANTOSHIMA COLONY,SECUNDERABAD, TELANGANA, INDIA

Accreditation Standard ISO/IEC 17025:2017

Certificate Number CC-2230 Page No. : 6 / 44

Validity 14/05/2019 to 13/05/2021 Last Amended on 23/05/2019

Page 8: CALIBRATION ISO/IEC 17025:2017 TRUECAL

S.No Discipline / Group Quantity Measured/Instrument

Range / Frequency * CalibrationMeasurementCapability(±)

Remarks

41 ELECTRO-TECHNICAL-ELECTRICALEQUIPMENT(Measure)

Resistance 1 MOhm to 10 MOhm 0.02% to 0.05% Using 8846A 6 1/2DMM using DirectMethod

42 ELECTRO-TECHNICAL-ELECTRICALEQUIPMENT(Measure)

Resistance 1 Ohm to 10 Ohm 0.417% Using Fluke 8846A 61/2 DMM by DirectMethod

43 ELECTRO-TECHNICAL-ELECTRICALEQUIPMENT(Measure)

Resistance 10 kOhm to 100 kOhm 0.013% to 0.01% Using Fluke 8846A 61/2 DMM by DirectMethod

44 ELECTRO-TECHNICAL-ELECTRICALEQUIPMENT(Measure)

Resistance 10 MOhm to 100MOhm

0.05% to 1.07% Using Fluke 8846A 61/2 DMM by DirectMethod

45 ELECTRO-TECHNICAL-ELECTRICALEQUIPMENT(Measure)

Resistance 10 Ohm to 100 Ohm 0.05% to 0.02% Using Fluke 8846A 61/2 DMM by DirectMethod

46 ELECTRO-TECHNICAL-ELECTRICALEQUIPMENT(Measure)

Resistance 100 kOhm to 1 MOhm 0.01% to 0.02% Using Fluke 8846A 81/2 DMM by DirectMethod

This is annexure to 'Certificate of Accreditation' and does not require any signature.

Laboratory Name TRUECAL, PLOT NO 18, FIRST FLOOR, SANTOSHIMA COLONY,SECUNDERABAD, TELANGANA, INDIA

Accreditation Standard ISO/IEC 17025:2017

Certificate Number CC-2230 Page No. : 7 / 44

Validity 14/05/2019 to 13/05/2021 Last Amended on 23/05/2019

Page 9: CALIBRATION ISO/IEC 17025:2017 TRUECAL

S.No Discipline / Group Quantity Measured/Instrument

Range / Frequency * CalibrationMeasurementCapability(±)

Remarks

47 ELECTRO-TECHNICAL-ELECTRICALEQUIPMENT(Measure)

Resistance 100 MOhm to 1 GOhm 1.07% to 4.31% Using 8846A 61/2DMM by Direct Method

48 ELECTRO-TECHNICAL-ELECTRICALEQUIPMENT(Measure)

Resistance 100 Ohm to 10 kOhm 0.02% to 0.013% Using Fluke 8846A 6 1/2 DMM by DirectMethod

49 ELECTRO-TECHNICAL-ELECTRICALEQUIPMENT (Source)

AC Power, 1 phase,50Hz @ 0.2 lag 120Vto 240 V, 0.1A to 20A

2.4 W to 960 W 1.2% Using MPC, Fluke5502A by DirectMethod

50 ELECTRO-TECHNICAL-ELECTRICALEQUIPMENT (Source)

AC Power, 1 phase,50Hz @ 0.5 lag 120Vto 240 V, 0.1A to 20A

6 W to 2.4 kW 0.8% Using MPC Fluke5502A by DirectMethod

51 ELECTRO-TECHNICAL-ELECTRICALEQUIPMENT (Source)

AC Power, 1 Phase,50Hz @ 0.8 Lead 120Vto 240 V, 0.1A to 20A

9.6 W to 3.8 kW 0.6% Using MPC Fluke5502A by DirectMethod

52 ELECTRO-TECHNICAL-ELECTRICALEQUIPMENT (Source)

AC Power, 1 Phase,50Hz @ UPF 120V to240 V, 0.01A to 20A

1.2 W to 4.8 kW 0.6% Using MPC Fluke5502A by DirectMethod

53 ELECTRO-TECHNICAL-ELECTRICALEQUIPMENT (Source)

AC Voltage 10 kHz -100 kHz

10 mV to 100 mV 0.4% to 0.15% Using Fluke MPC5522A by DirectMethod

This is annexure to 'Certificate of Accreditation' and does not require any signature.

Laboratory Name TRUECAL, PLOT NO 18, FIRST FLOOR, SANTOSHIMA COLONY,SECUNDERABAD, TELANGANA, INDIA

Accreditation Standard ISO/IEC 17025:2017

Certificate Number CC-2230 Page No. : 8 / 44

Validity 14/05/2019 to 13/05/2021 Last Amended on 23/05/2019

Page 10: CALIBRATION ISO/IEC 17025:2017 TRUECAL

S.No Discipline / Group Quantity Measured/Instrument

Range / Frequency * CalibrationMeasurementCapability(±)

Remarks

54 ELECTRO-TECHNICAL-ELECTRICALEQUIPMENT (Source)

AC Voltage 10 kHz -100 kHz

100 mV to 1 V 0.96% to 0.1% Using Fluke MPC5522A by DirectMethod

55 ELECTRO-TECHNICAL-ELECTRICALEQUIPMENT (Source)

AC Voltage 10 kHz to100 kHz

1 V to 100 V 0.1% to 0.297% Using Calibrator FlukeMPC 5522A by Directmethod

56 ELECTRO-TECHNICAL-ELECTRICALEQUIPMENT (Source)

AC Voltage 50 Hz to10kHz

100 mV to 100 V 0.03% Using Calibrator FlukeMPC 5522A by Directmethod

57 ELECTRO-TECHNICAL-ELECTRICALEQUIPMENT (Source)

AC Voltage 50 Hz to10kHz

3 mV to 100 mV 0.24% to 0.03% Using Calibrator FlukeMPC 5522A by directmethod

58 ELECTRO-TECHNICAL-ELECTRICALEQUIPMENT (Source)

AC Voltage 50 Hz to1kHz

100 V to 1000 V 0.04% Using Calibrator FlukeMPC 5522A by Directmethod

59 ELECTRO-TECHNICAL-ELECTRICALEQUIPMENT (Source)

DC Power @ 1 V to600 V & 1 mA to 1000A

1 kW to 600 kW 0.6% to 1% Using Fluke 5502A with5500A current coil byDirect method

60 ELECTRO-TECHNICAL-ELECTRICALEQUIPMENT (Source)

DC Power @ 1 V to600 V & 1 mA to 1000A

1 mW to 1 kW 0.1% to 0.6% Using Fluke 5502A with5500A current coil byDirect method

61 ELECTRO-TECHNICAL-ELECTRICALEQUIPMENT (Source)

DC Resistance 1 GOhm to 1 TOhm 1.19% Using standardResistors by DirectMethod

This is annexure to 'Certificate of Accreditation' and does not require any signature.

Laboratory Name TRUECAL, PLOT NO 18, FIRST FLOOR, SANTOSHIMA COLONY,SECUNDERABAD, TELANGANA, INDIA

Accreditation Standard ISO/IEC 17025:2017

Certificate Number CC-2230 Page No. : 9 / 44

Validity 14/05/2019 to 13/05/2021 Last Amended on 23/05/2019

Page 11: CALIBRATION ISO/IEC 17025:2017 TRUECAL

S.No Discipline / Group Quantity Measured/Instrument

Range / Frequency * CalibrationMeasurementCapability(±)

Remarks

62 ELECTRO-TECHNICAL-ELECTRICALEQUIPMENT (Source)

DC Resistance 1 mOhm 0.67% Using StandardResistors by DirectMethod

63 ELECTRO-TECHNICAL-ELECTRICALEQUIPMENT (Source)

DC Resistance 1 MOhm to 100 MOhm 0.004% to 0.06% Using Fluke MPC5522A by DirectMethod

64 ELECTRO-TECHNICAL-ELECTRICALEQUIPMENT (Source)

DC Resistance 1 Ohm to 10 Ohm 0.1% to 0.02% direct Method/Using5522A

65 ELECTRO-TECHNICAL-ELECTRICALEQUIPMENT (Source)

DC Resistance 10 mohm 0.26% Using standardResistors by DirectMethod

66 ELECTRO-TECHNICAL-ELECTRICALEQUIPMENT (Source)

DC Resistance 10 Ohm to 1 MOhm 0.02% to 0.004% Using Fluke MPC5522A by DirectMethod

67 ELECTRO-TECHNICAL-ELECTRICALEQUIPMENT (Source)

DC Resistance 100 MOhm to 1 GOhm 0.06% to 1% Using Fluke MPC5522A by DirectMethod

68 ELECTRO-TECHNICAL-ELECTRICALEQUIPMENT (Source)

DC Resistance 100mOhm 0.26% Using StandardResistors by DirectMethod

69 ELECTRO-TECHNICAL-ELECTRICALEQUIPMENT (Source)

DC Voltage 1 V to 10 V 0.0017% Using Calibrator FlukeMPC 5522A

This is annexure to 'Certificate of Accreditation' and does not require any signature.

Laboratory Name TRUECAL, PLOT NO 18, FIRST FLOOR, SANTOSHIMA COLONY,SECUNDERABAD, TELANGANA, INDIA

Accreditation Standard ISO/IEC 17025:2017

Certificate Number CC-2230 Page No. : 10 / 44

Validity 14/05/2019 to 13/05/2021 Last Amended on 23/05/2019

Page 12: CALIBRATION ISO/IEC 17025:2017 TRUECAL

S.No Discipline / Group Quantity Measured/Instrument

Range / Frequency * CalibrationMeasurementCapability(±)

Remarks

70 ELECTRO-TECHNICAL-ELECTRICALEQUIPMENT (Source)

DC Voltage 10 mV to 1 V 0.043% to 0.0015% Using Calibrator FlukeMC 5522A

71 ELECTRO-TECHNICAL-ELECTRICALEQUIPMENT (Source)

DC Voltage 10 V to 1000 V 0.0015% to 0.0023% Using Calibrator FlukeMPC 5522A

72 ELECTRO-TECHNICAL-ELECTRICALEQUIPMENT (Source)

Frequency 1 Hz to 1 MHz 0.12% to 0.0029% Using Fluke MPC5502A, R&S SignalGenerator SMY 02 byDirect Method

73 ELECTRO-TECHNICAL-ELECTRICALEQUIPMENT (Source)

Frequency 1 MHz to 2 GHz 3.48ppm Using Fluke MPC5502A, R & S SignalGenerator SMY 02 byDirect Method

74 ELECTRO-TECHNICAL-ELECTRICALEQUIPMENT (Source)

Oscilloscope Amplitude 5 mV p-p to 60 (SquareWave Signal) V p-p

0.64% Using Fluke MPC5502A by DirectMethod

75 ELECTRO-TECHNICAL-ELECTRICALEQUIPMENT (Source)

Oscilloscope BandWidth

250 MHz to 2 GHz 6.7% Using Signal GeneratorSMY 02 by DirectMethod

76 ELECTRO-TECHNICAL-ELECTRICALEQUIPMENT (Source)

Oscilloscope BandWidth

50 MHz to 250 MHz 3.0% Using Signal GeneratorSMY 02 by DirectMethod

77 ELECTRO-TECHNICAL-ELECTRICALEQUIPMENT (Source)

Oscilloscope TimeMarker

1 ns to 5 s 0.06% to 0.58% Using Time MarkGenerator TG 201 byDirect Method

This is annexure to 'Certificate of Accreditation' and does not require any signature.

Laboratory Name TRUECAL, PLOT NO 18, FIRST FLOOR, SANTOSHIMA COLONY,SECUNDERABAD, TELANGANA, INDIA

Accreditation Standard ISO/IEC 17025:2017

Certificate Number CC-2230 Page No. : 11 / 44

Validity 14/05/2019 to 13/05/2021 Last Amended on 23/05/2019

Page 13: CALIBRATION ISO/IEC 17025:2017 TRUECAL

S.No Discipline / Group Quantity Measured/Instrument

Range / Frequency * CalibrationMeasurementCapability(±)

Remarks

78 ELECTRO-TECHNICAL-TEMPERATURESIMULATION(Measure)

TemperatureSimulation (Calibrationof temperatureIndicator/Controller/Recorder/Calibrator)RTD

(-)200 °C to 800 °C 0.3°C Using Fluke 5502A inMeasure by DirectMethod

79 ELECTRO-TECHNICAL-TEMPERATURESIMULATION(Measure)

TemperatureSimulation (Calibrationof temperatureIndicator/Controller/Recorder/Calibrator)Thermocouples .NType

(-)200 °C to 1300 °C 0.6°C Using Fluke 5502A inMeasure mode byDirect Method

80 ELECTRO-TECHNICAL-TEMPERATURESIMULATION(Measure)

TemperatureSimulation (Calibrationof temperatureIndicator/Controller/Recorder/Calibrator)Thermocouples B type

600 °C to 1800 °C 0.68°C Using Fluke 5502A inMeasure mode byDirect Method

81 ELECTRO-TECHNICAL-TEMPERATURESIMULATION(Measure)

TemperatureSimulation (Calibrationof temperatureIndicator/Controller/Recorder/Calibrator)Thermocouples E type

(-)200 °C to 1000 °C 0.6°C Using Fluke 5502A inMeasure mode byDirect Method

82 ELECTRO-TECHNICAL-TEMPERATURESIMULATION(Measure)

TemperatureSimulation (Calibrationof temperatureIndicator/Controller/Recorder/Calibrator)Thermocouples J type

(-)200 °C to 1200 °C 0.51°C Using Fluke 5502A inMeasure mode byDirect Method

This is annexure to 'Certificate of Accreditation' and does not require any signature.

Laboratory Name TRUECAL, PLOT NO 18, FIRST FLOOR, SANTOSHIMA COLONY,SECUNDERABAD, TELANGANA, INDIA

Accreditation Standard ISO/IEC 17025:2017

Certificate Number CC-2230 Page No. : 12 / 44

Validity 14/05/2019 to 13/05/2021 Last Amended on 23/05/2019

Page 14: CALIBRATION ISO/IEC 17025:2017 TRUECAL

S.No Discipline / Group Quantity Measured/Instrument

Range / Frequency * CalibrationMeasurementCapability(±)

Remarks

83 ELECTRO-TECHNICAL-TEMPERATURESIMULATION(Measure)

TemperatureSimulation (Calibrationof temperatureIndicator/Controller/Recorder/Calibrator)Thermocouples K type

(-)200 °C to 1350 °C 0.7°C Using Fluke 5502A inMeasure mode byDirect Method

84 ELECTRO-TECHNICAL-TEMPERATURESIMULATION(Measure)

TemperatureSimulation (Calibrationof temperatureIndicator/Controller/Recorder/Calibrator)Thermocouples R type

0 °C to 1750 °C 1.1°C Using Fluke 5502A inMeasure mode byDirect Method

85 ELECTRO-TECHNICAL-TEMPERATURESIMULATION(Measure)

TemperatureSimulation (Calibrationof temperatureIndicator/Controller/Recorder/Calibrator)Thermocouples S type

0 °C to 1750 °C 1.1°C Using Fluke 5502A inMeasure mode byDirect Method

86 ELECTRO-TECHNICAL-TEMPERATURESIMULATION(Measure)

TemperatureSimulation (Calibrationof temperatureIndicator/Controller/Recorder/Calibrator)Thermocouples T type

(-)200 °C to 400 °C 0.7°C Using Fluke 5502A inMeasure mode byDirect Method

87 ELECTRO-TECHNICAL-TEMPERATURESIMULATION (Source)

(Calibration ofTemperature Indicator/controller/Recorder/Calibrator) RTDthermocouples

-200 °C to 800 °C 0.3°C Using Fluke MPC5522A by DirectMethod

88 ELECTRO-TECHNICAL-TEMPERATURESIMULATION (Source)

(Calibrtion ofTemperatureIndicator/Controller/Recorder/Calibrator) J type

(-)200 °C to 1200 °C 0.51°C Using Fluke MPC5522A by DirectMethod

This is annexure to 'Certificate of Accreditation' and does not require any signature.

Laboratory Name TRUECAL, PLOT NO 18, FIRST FLOOR, SANTOSHIMA COLONY,SECUNDERABAD, TELANGANA, INDIA

Accreditation Standard ISO/IEC 17025:2017

Certificate Number CC-2230 Page No. : 13 / 44

Validity 14/05/2019 to 13/05/2021 Last Amended on 23/05/2019

Page 15: CALIBRATION ISO/IEC 17025:2017 TRUECAL

S.No Discipline / Group Quantity Measured/Instrument

Range / Frequency * CalibrationMeasurementCapability(±)

Remarks

89 ELECTRO-TECHNICAL-TEMPERATURESIMULATION (Source)

(Calibrtion ofTemperatureIndicator/Controller/Recorder/Calibrator)Thermocouple B Type

600 °C to 1800 °C 1.03°C Using Fluke MPC5522A by DirectMethod

90 ELECTRO-TECHNICAL-TEMPERATURESIMULATION (Source)

(Calibrtion ofTemperatureIndicator/Controller/Recorder/Calibrator)Thermocouple E Type

(-)200 °C to 1000 °C 0.25°C Using Fluke MPC5522A by DirectMethod

91 ELECTRO-TECHNICAL-TEMPERATURESIMULATION (Source)

(Calibrtion ofTemperatureIndicator/Controller/Recorder/Calibrator)Thermocouple K Type

(-)200 °C to 1350 °C 0.35°C Using Fluke MPC5522A by Directmethod

92 ELECTRO-TECHNICAL-TEMPERATURESIMULATION (Source)

(Calibrtion ofTemperatureIndicator/Controller/Recorder/Calibrator)Thermocouple N Type

(-)200 °C to 1300 °C 0.25°C Using Fluke MPC5522A by DirectMethod

93 ELECTRO-TECHNICAL-TEMPERATURESIMULATION (Source)

(Calibrtion ofTemperatureIndicator/Controller/Recorder/Calibrator)Thermocouple R Type

70 °C to 1750 °C 0.74°C Using Fluke MPC5522A by DirectMethod

94 ELECTRO-TECHNICAL-TEMPERATURESIMULATION (Source)

(Calibrtion ofTemperatureIndicator/Controller/Recorder/Calibrator)Thermocouple S Type

70 °C to 1750 °C 0.25°C Using Fluke MPC5522A by DirectMethod

This is annexure to 'Certificate of Accreditation' and does not require any signature.

Laboratory Name TRUECAL, PLOT NO 18, FIRST FLOOR, SANTOSHIMA COLONY,SECUNDERABAD, TELANGANA, INDIA

Accreditation Standard ISO/IEC 17025:2017

Certificate Number CC-2230 Page No. : 14 / 44

Validity 14/05/2019 to 13/05/2021 Last Amended on 23/05/2019

Page 16: CALIBRATION ISO/IEC 17025:2017 TRUECAL

S.No Discipline / Group Quantity Measured/Instrument

Range / Frequency * CalibrationMeasurementCapability(±)

Remarks

95 ELECTRO-TECHNICAL-TEMPERATURESIMULATION (Source)

(Calibrtion ofTemperatureIndicator/Controller/Recorder/Calibrator)Thermocouple T Type

(-)200 °C to 400 °C 0.4°C Using Fluke MPC5522A by DirectMethod

96 ELECTRO-TECHNICAL- TIME &FREQUENCY(Measure)

Stop Watch 5 s to 86400 s 2% to 0.084% Using Stop Watch byComparison method

97 ELECTRO-TECHNICAL- TIME &FREQUENCY(Measure)

Timer 500 msec to 9000 sec 1.41% to 0.084% Using Timer byComparison Method

98 ELECTRO-TECHNICAL- TIME &FREQUENCY(Measure)

Timer 9000 sec to 86400 sec 0.27% Using Timer byComparison method

99 MECHANICAL-DIMENSION (BASICMEASURINGINSTRUMENT,GAUGE ETC.)

Bevel Protractor L. C.:5 Arc Min

0 ° to 90 ° 1.0 arc min Using Sine Bar

100 MECHANICAL-DIMENSION (BASICMEASURINGINSTRUMENT,GAUGE ETC.)

Bore Dial Gauge(Digital/Dial) L. C.: 1µm

0 to 1mm 2.0 µm Using LengthMeasuring Machine

101 MECHANICAL-DIMENSION (BASICMEASURINGINSTRUMENT,GAUGE ETC.)

Caliper ( Vernier, Dial,Digital) L.C. 10µm

0 mm to 1000 mm 10.8µm Using Grade “0” GaugeBlocks/Caliper Checkerby comparison methodbased on IS 3651

This is annexure to 'Certificate of Accreditation' and does not require any signature.

Laboratory Name TRUECAL, PLOT NO 18, FIRST FLOOR, SANTOSHIMA COLONY,SECUNDERABAD, TELANGANA, INDIA

Accreditation Standard ISO/IEC 17025:2017

Certificate Number CC-2230 Page No. : 15 / 44

Validity 14/05/2019 to 13/05/2021 Last Amended on 23/05/2019

Page 17: CALIBRATION ISO/IEC 17025:2017 TRUECAL

S.No Discipline / Group Quantity Measured/Instrument

Range / Frequency * CalibrationMeasurementCapability(±)

Remarks

102 MECHANICAL-DIMENSION (BASICMEASURINGINSTRUMENT,GAUGE ETC.)

Caliper (Vernier, Dial,Digital) L.C. 10µm

0 mm to 600 mm 8.5µm Using grade 0 gaugeblocks / CaliperChecker by comparisonmethod based on IS3651

103 MECHANICAL-DIMENSION (BASICMEASURINGINSTRUMENT,GAUGE ETC.)

Comparator Stand /Dial Gauge Stand

Up to 200 mm 2.3µm Using Lever DialGauge

104 MECHANICAL-DIMENSION (BASICMEASURINGINSTRUMENT,GAUGE ETC.)

Cylindrical MeasuringPin (Grade 2 & 3)

Up to Ø 26 mm 2.0µm Using FCDM

105 MECHANICAL-DIMENSION (BASICMEASURINGINSTRUMENT,GAUGE ETC.)

Depth Caliper L. C. : 10µm

0 mm to 300 mm 6.0µm Using Grade “O”Gauge Block Set

106 MECHANICAL-DIMENSION (BASICMEASURINGINSTRUMENT,GAUGE ETC.)

Depth Micrometer L.C.: 10µm

0 mm to 300 mm 5.9µm Using Grade “O”Gauge Block Set

107 MECHANICAL-DIMENSION (BASICMEASURINGINSTRUMENT,GAUGE ETC.)

Dial Gauge Lever Type(Digital/Dial) L. C.: 1µm

Up to 2 mm 0.3µm Using LengthMeasuring Machine

This is annexure to 'Certificate of Accreditation' and does not require any signature.

Laboratory Name TRUECAL, PLOT NO 18, FIRST FLOOR, SANTOSHIMA COLONY,SECUNDERABAD, TELANGANA, INDIA

Accreditation Standard ISO/IEC 17025:2017

Certificate Number CC-2230 Page No. : 16 / 44

Validity 14/05/2019 to 13/05/2021 Last Amended on 23/05/2019

Page 18: CALIBRATION ISO/IEC 17025:2017 TRUECAL

S.No Discipline / Group Quantity Measured/Instrument

Range / Frequency * CalibrationMeasurementCapability(±)

Remarks

108 MECHANICAL-DIMENSION (BASICMEASURINGINSTRUMENT,GAUGE ETC.)

Dial Gauge PlungerType (Digital/Dial) L.C.: 1 µm

Up to 50 mm 0.4µm Using LengthMeasuring Machine

109 MECHANICAL-DIMENSION (BASICMEASURINGINSTRUMENT,GAUGE ETC.)

Dial Thickness gauge,L.C. 1 µm

0 mm to 10 mm 1.7µm Using Gauge Block SetGrade 0, bycomparison method

110 MECHANICAL-DIMENSION (BASICMEASURINGINSTRUMENT,GAUGE ETC.)

External Micrometer(Mech/Electronic/Digital) L.C.: 1µm

Up to 300 mm 2.7µm Using Grade “0” GaugeBlocks

111 MECHANICAL-DIMENSION (BASICMEASURINGINSTRUMENT,GAUGE ETC.)

External Micrometer(Mech/Electronic/Digital) L.C.: 10µm

Up to 1000 mm 7.6µm Using Grade “0” GaugeBlocks

112 MECHANICAL-DIMENSION (BASICMEASURINGINSTRUMENT,GAUGE ETC.)

Feeler Gauge Up to 1 mm 1.9µm Using DigitalMicrometer

113 MECHANICAL-DIMENSION (BASICMEASURINGINSTRUMENT,GAUGE ETC.)

Height Gauge (Vernier/ Dial / Digital) L. C.:10µm

0 mm to 1000 mm 7.6µm Using Grade “0” GaugeBlock/ Caliper Checker

This is annexure to 'Certificate of Accreditation' and does not require any signature.

Laboratory Name TRUECAL, PLOT NO 18, FIRST FLOOR, SANTOSHIMA COLONY,SECUNDERABAD, TELANGANA, INDIA

Accreditation Standard ISO/IEC 17025:2017

Certificate Number CC-2230 Page No. : 17 / 44

Validity 14/05/2019 to 13/05/2021 Last Amended on 23/05/2019

Page 19: CALIBRATION ISO/IEC 17025:2017 TRUECAL

S.No Discipline / Group Quantity Measured/Instrument

Range / Frequency * CalibrationMeasurementCapability(±)

Remarks

114 MECHANICAL-DIMENSION (BASICMEASURINGINSTRUMENT,GAUGE ETC.)

Inside Dial/Leg CaliperL. C.: 10µm

Ø 20 mm to Ø 100 mm 7.0µm Using Grade “O”Gauge Block

115 MECHANICAL-DIMENSION (BASICMEASURINGINSTRUMENT,GAUGE ETC.)

Internal StickMicrometer L. C.: 10µm

50 mm to 2100 mm 5.8 + (L/780) µm ‘L’length in mm

Using Grade “O”Gauge Block Set withAccessories

116 MECHANICAL-DIMENSION (BASICMEASURINGINSTRUMENT,GAUGE ETC.)

Pistol Caliper L. C.:100µm

Ø 20 mm to Ø 100 mm 64µm Using Grade “O”Gauge Block

117 MECHANICAL-DIMENSION (BASICMEASURINGINSTRUMENT,GAUGE ETC.)

Plain Plug Gauge 0 to Ø 100 mm 1.9µm Using CylindricalMaster, FCDM

118 MECHANICAL-DIMENSION (BASICMEASURINGINSTRUMENT,GAUGE ETC.)

Plain Ring Gauge Ø3mm to Ø 100 mm 2.0µm Using LengthMeasuring Machine/Master Ring Gauge

119 MECHANICAL-DIMENSION (BASICMEASURINGINSTRUMENT,GAUGE ETC.)

Snap Gauge 2 mm to 200 mm 2.6µm Using Grade "O"Gauge Block Set

This is annexure to 'Certificate of Accreditation' and does not require any signature.

Laboratory Name TRUECAL, PLOT NO 18, FIRST FLOOR, SANTOSHIMA COLONY,SECUNDERABAD, TELANGANA, INDIA

Accreditation Standard ISO/IEC 17025:2017

Certificate Number CC-2230 Page No. : 18 / 44

Validity 14/05/2019 to 13/05/2021 Last Amended on 23/05/2019

Page 20: CALIBRATION ISO/IEC 17025:2017 TRUECAL

S.No Discipline / Group Quantity Measured/Instrument

Range / Frequency * CalibrationMeasurementCapability(±)

Remarks

120 MECHANICAL-DIMENSION (BASICMEASURINGINSTRUMENT,GAUGE ETC.)

Taper Thread PlugGauge

0 to 100 mm 2.1µm Using LengthMeasuring Machine

121 MECHANICAL-DIMENSION (BASICMEASURINGINSTRUMENT,GAUGE ETC.)

Thickness Foils 0 to 25mm 2.4µm Using DigitalMicrometer

122 MECHANICAL-DIMENSION (BASICMEASURINGINSTRUMENT,GAUGE ETC.)

Thread Plug Gauge 0 to Ø 100 mm 2.6µm Using CylindricalMaster, Threadmeasuring wires,FCDM

123 MECHANICAL-DIMENSION (BASICMEASURINGINSTRUMENT,GAUGE ETC.)

Thread Ring Gauge(For Effective Dia)

Ø 3mm to Ø 100 mm 2.0µm Using LengthMeasuring Machine/Master Ring Gauge

124 MECHANICAL-DIMENSION (BASICMEASURINGINSTRUMENT,GAUGE ETC.)

Three Point MicrometerL. C.: 1 µm

Ø 3 mm to Ø 100 mm 3.6µm Using Setting RingGauges

125 MECHANICAL-DIMENSION (BASICMEASURINGINSTRUMENT,GAUGE ETC.)

Ultrasonic ThicknessGauge L. C.: 100µm

Up to 100 mm 30.1µm Using Gauge Block Set

This is annexure to 'Certificate of Accreditation' and does not require any signature.

Laboratory Name TRUECAL, PLOT NO 18, FIRST FLOOR, SANTOSHIMA COLONY,SECUNDERABAD, TELANGANA, INDIA

Accreditation Standard ISO/IEC 17025:2017

Certificate Number CC-2230 Page No. : 19 / 44

Validity 14/05/2019 to 13/05/2021 Last Amended on 23/05/2019

Page 21: CALIBRATION ISO/IEC 17025:2017 TRUECAL

S.No Discipline / Group Quantity Measured/Instrument

Range / Frequency * CalibrationMeasurementCapability(±)

Remarks

126 MECHANICAL-PRESSUREINDICATING DEVICES

Digital/AnalogueVacuum Gauges,Transducers/Transmitters, switches

0 bar to -0.95 bar 1.184% rdg Using PneumaticVacuum ComparatorDigital Pressure GaugePump by comparisonmethod based on DKD-R6-1

127 MECHANICAL-PRESSUREINDICATING DEVICES

Hydraulic PressureDigital/Analoguegauges,Transducers/Transmitters, Switches

0 bar to 1000 bar 0.123% rdg using HydraulicComparator pumpDigital Pressure Gaugeby comparison methodbased on DKD-R6-1.

128 MECHANICAL-PRESSUREINDICATING DEVICES

Pneumatic PressureDigital/AnaloguePressure gauges,Transducers/Transmitters, switches

0 bar to 40 bar 0.156% rdg Using PneumaticPressure ComparatorPump Digital PressureGauge by comparisonbased on DKD-R6-1

129 MECHANICAL-TORQUEGENERATINGDEVICES

Torque Wrench,Torque Driver (Type I-CLass A, B, C, D, E)(Type II- Class A, B, C,D, E) Clockwisedirection only

2 Nm to 500 Nm 0.69% rdg Using Torque Sensorswith Indicator based onISO 6789:2017

130 MECHANICAL-VOLUME

Micro Pipettes 10 µl to 100 µl 0.11µl Using WeighingBalance with aresolution of 0.01 mgbased on Gravimetricmethod as Per ISO8655 part 6

This is annexure to 'Certificate of Accreditation' and does not require any signature.

Laboratory Name TRUECAL, PLOT NO 18, FIRST FLOOR, SANTOSHIMA COLONY,SECUNDERABAD, TELANGANA, INDIA

Accreditation Standard ISO/IEC 17025:2017

Certificate Number CC-2230 Page No. : 20 / 44

Validity 14/05/2019 to 13/05/2021 Last Amended on 23/05/2019

Page 22: CALIBRATION ISO/IEC 17025:2017 TRUECAL

S.No Discipline / Group Quantity Measured/Instrument

Range / Frequency * CalibrationMeasurementCapability(±)

Remarks

131 MECHANICAL-VOLUME

Micro Pipettes 100 µl to 1000 µl 0.12µl Using WeighingBalance with aresolution of 0.01 mgbased on Gravimetricmethod as Per ISO8655 part 6

132 MECHANICAL-VOLUME

One mark Pipette,Graduated Pipette,Graduated Burette,Volumetric Flask,Measuring jar

1 ml to 10 ml 0.00018ml Using Precisionbalance with areadability 0.1 mg, 1mg, 10 mg and distilledwater by GravimetricMethod as per ISO4787

133 MECHANICAL-VOLUME

One mark Pipette,Graduated Pipette,Graduated Burette,Volumetric Flask,Measuring jar

10 ml to 100 ml 0.0004ml Using precisionweighing balance ofd=0.1 mg, 1 mg, 10 mgand distilled waterbased on Gravimetricmethod as per ISO4787

134 MECHANICAL-VOLUME

One mark Pipette,Graduated Pipette,Graduated Burette,Volumetric Flask,Measuring jar

100 ml to 1000 ml 0.005ml Using Precisionbalance with areadability 0.1 mg, 1mg, 10 mg and distilledwater by GravimetricMethod as per ISO4787

This is annexure to 'Certificate of Accreditation' and does not require any signature.

Laboratory Name TRUECAL, PLOT NO 18, FIRST FLOOR, SANTOSHIMA COLONY,SECUNDERABAD, TELANGANA, INDIA

Accreditation Standard ISO/IEC 17025:2017

Certificate Number CC-2230 Page No. : 21 / 44

Validity 14/05/2019 to 13/05/2021 Last Amended on 23/05/2019

Page 23: CALIBRATION ISO/IEC 17025:2017 TRUECAL

S.No Discipline / Group Quantity Measured/Instrument

Range / Frequency * CalibrationMeasurementCapability(±)

Remarks

135 MECHANICAL-VOLUME

One mark Pipette,Graduated Pipette,Graduated Burette,Volumetric Flask,Measuring jar

1000 ml to 5000 ml 0.069ml Using Precisionbalance with areadability 0.1 mg, 1mg, 10 mg and distilledwater by GravimetricMethod as per ISO4787

136 MECHANICAL-WEIGHTS

F1 Class and Coarser 1 g 0.012mg Using PrecisionBalance with aReadability 0.01/ 0.1mg / 1 mg / 10 mg Asper OIML R – 111-1

137 MECHANICAL-WEIGHTS

F1 Class and Coarser 10 g 0.02mg Using PrecisionBalance with aReadability 0.01/ 0.1mg / 1 mg / 10 mg Asper OIML R – 111-1

138 MECHANICAL-WEIGHTS

F1 Class and Coarser 100 g 0.10mg Using PrecisionBalance with aReadability 0.01/ 0.1mg / 1 mg / 10 mg Asper OIML R – 111-1

139 MECHANICAL-WEIGHTS

F1 Class and Coarser 100 mg 0.01mg Using PrecisionBalance with aReadability 0.01/ 0.1mg / 1 mg / 10 mg Asper OIML R – 111-1

140 MECHANICAL-WEIGHTS

F1 Class and Coarser 2 g 0.012mg Using PrecisionBalance with aReadability 0.01/ 0.1mg / 1 mg / 10 mg Asper OIML R – 111-1

This is annexure to 'Certificate of Accreditation' and does not require any signature.

Laboratory Name TRUECAL, PLOT NO 18, FIRST FLOOR, SANTOSHIMA COLONY,SECUNDERABAD, TELANGANA, INDIA

Accreditation Standard ISO/IEC 17025:2017

Certificate Number CC-2230 Page No. : 22 / 44

Validity 14/05/2019 to 13/05/2021 Last Amended on 23/05/2019

Page 24: CALIBRATION ISO/IEC 17025:2017 TRUECAL

S.No Discipline / Group Quantity Measured/Instrument

Range / Frequency * CalibrationMeasurementCapability(±)

Remarks

141 MECHANICAL-WEIGHTS

F1 Class and Coarser 20 g 0.02mg Using PrecisionBalance with aReadability 0.01/ 0.1mg / 1 mg / 10 mg Asper OIML R – 111-1

142 MECHANICAL-WEIGHTS

F1 Class and Coarser 20 mg 0.01mg Using PrecisionBalance with aReadability 0.01/ 0.1mg / 1 mg / 10 mg Asper OIML R – 111-1

143 MECHANICAL-WEIGHTS

F1 Class and Coarser 200 g 0.10mg Using PrecisionBalance with aReadability 0.01/ 0.1mg / 1 mg / 10 mg Asper OIML R – 111-1

144 MECHANICAL-WEIGHTS

F1 Class and Coarser 200 mg 0.01mg Using PrecisionBalance with aReadability 0.01/ 0.1mg / 1 mg / 10 mg Asper OIML R – 111-1

145 MECHANICAL-WEIGHTS

F1 Class and Coarser 5 g 0.013mg Using PrecisionBalance with aReadability 0.01/ 0.1mg / 1 mg / 10 mg Asper OIML R – 111-1

146 MECHANICAL-WEIGHTS

F1 Class and Coarser 50 g 0.03mg Using PrecisionBalance with aReadability 0.01/ 0.1mg / 1 mg / 10 mg Asper OIML R – 111-1

This is annexure to 'Certificate of Accreditation' and does not require any signature.

Laboratory Name TRUECAL, PLOT NO 18, FIRST FLOOR, SANTOSHIMA COLONY,SECUNDERABAD, TELANGANA, INDIA

Accreditation Standard ISO/IEC 17025:2017

Certificate Number CC-2230 Page No. : 23 / 44

Validity 14/05/2019 to 13/05/2021 Last Amended on 23/05/2019

Page 25: CALIBRATION ISO/IEC 17025:2017 TRUECAL

S.No Discipline / Group Quantity Measured/Instrument

Range / Frequency * CalibrationMeasurementCapability(±)

Remarks

147 MECHANICAL-WEIGHTS

F1 Class and Coarser 50 mg 0.01mg Using PrecisionBalance with aReadability 0.01/ 0.1mg / 1 mg / 10 mg Asper OIML R – 111-1

148 MECHANICAL-WEIGHTS

F1 Class and Coarser 500 g 1mg Using PrecisionBalance with aReadability 0.01/ 0.1mg / 1 mg / 10 mg Asper OIML R – 111-1

149 MECHANICAL-WEIGHTS

F1 Class and Coarser 500 mg 0.010mg Using PrecisionBalance with aReadability 0.01/ 0.1mg / 1 mg / 10 mg Asper OIML R – 111-1

150 MECHANICAL-WEIGHTS

F1 Class Weight 1 mg 0.01mg Using PrecisionBalance with aReadability 0.01/0.1mg/1mg/ 10mg As perOIML R - 111 - 1

151 MECHANICAL-WEIGHTS

F2 Class and Coarser 1 kg 11mg Using E2 classStandard weights &precision balance witha Readability 0.001 g/0.01g as per OIML R –111

152 MECHANICAL-WEIGHTS

F2 Class and Coarser 2 kg 10mg Using E2 classStandard weights &precision balance witha Readability 0.001 g/0.01g as per OIML R –111

This is annexure to 'Certificate of Accreditation' and does not require any signature.

Laboratory Name TRUECAL, PLOT NO 18, FIRST FLOOR, SANTOSHIMA COLONY,SECUNDERABAD, TELANGANA, INDIA

Accreditation Standard ISO/IEC 17025:2017

Certificate Number CC-2230 Page No. : 24 / 44

Validity 14/05/2019 to 13/05/2021 Last Amended on 23/05/2019

Page 26: CALIBRATION ISO/IEC 17025:2017 TRUECAL

S.No Discipline / Group Quantity Measured/Instrument

Range / Frequency * CalibrationMeasurementCapability(±)

Remarks

153 MECHANICAL-WEIGHTS

F2 Class and Coarser 5 kg 12mg Using E2 classStandard weights &precision balance witha Readability 0.001 g/0.01g as per OIML R –111

154 MECHANICAL-WEIGHTS

F2 Class Weights andCoarser weights

20 kg 113mg Using F1 classstandard weights andprecision balance witha readability of 0.001kg / 0.1

155 MECHANICAL-WEIGHTS

M1 Class Weights andCoarser weights

10 kg 99mg Using F1 class weightsand precision balancewith a readability 0.001kg / 0.1 g

156 MECHANICAL-WEIGHTS

M1 Class Weights andCoarser weights

50 kg 817mg Using F1 classstandard weights andprecision balance witha readability of 0.001kg / 0.1 g

157 MECHANICAL-WEIGHTS

Weights F1 Class andCoarser

10 mg 0.01mg Using PrecisionBalance with aReadability 0.01/0.1mg/1mg/ 10mg As perOIML R - 111 -

158 MECHANICAL-WEIGHTS

Weights F1 Class andCoarser

2 mg 0.01mg Using PrecisionBalance with aReadability 0.01/0.1mg/1mg/ 10mg As perOIML R - 111 -

This is annexure to 'Certificate of Accreditation' and does not require any signature.

Laboratory Name TRUECAL, PLOT NO 18, FIRST FLOOR, SANTOSHIMA COLONY,SECUNDERABAD, TELANGANA, INDIA

Accreditation Standard ISO/IEC 17025:2017

Certificate Number CC-2230 Page No. : 25 / 44

Validity 14/05/2019 to 13/05/2021 Last Amended on 23/05/2019

Page 27: CALIBRATION ISO/IEC 17025:2017 TRUECAL

S.No Discipline / Group Quantity Measured/Instrument

Range / Frequency * CalibrationMeasurementCapability(±)

Remarks

159 MECHANICAL-WEIGHTS

Weights F1 Class andCoarser

5 mg 0.01mg Using PrecisionBalance with aReadability 0.01/0.1mg/1mg/ 10mg As perOIML R - 111 -

160 THERMAL- SPECIFICHEAT & HUMIDITY

Hygrometer, HumidityMeter/Logger, 5°C to50°C

15% RH to 95% RH 0.92%RH Using ThermoHygrometer withTemperature HumidityGenerator ByComparison Method

161 THERMAL-TEMPERATURE

Glass Thermometer (-) 40 °C to 200 °C 0.48°C Using Std. RTD (PT100), 6 ½ digit DMM,Low/High TemperatureOil Bath ByComparison Method

162 THERMAL-TEMPERATURE

RTD, Thermocouple,Temperature Sensors& Digital Thermometer

400 °C to 1000 °C 1.89°C Using Std. S Type T/C,6 ½ digit DMM ,Furnace ByComparison Method

163 THERMAL-TEMPERATURE

RTD, Thermocouples,Digital Thermometer &Dial Thermometer0

-40 °C to 400 °C 0.38°C Using Std. RTD (PT100), 6 ½ digit DMM,Low/High TemperatureOil Bath, Furnace ByComparison Method

This is annexure to 'Certificate of Accreditation' and does not require any signature.

Laboratory Name TRUECAL, PLOT NO 18, FIRST FLOOR, SANTOSHIMA COLONY,SECUNDERABAD, TELANGANA, INDIA

Accreditation Standard ISO/IEC 17025:2017

Certificate Number CC-2230 Page No. : 26 / 44

Validity 14/05/2019 to 13/05/2021 Last Amended on 23/05/2019

Page 28: CALIBRATION ISO/IEC 17025:2017 TRUECAL

S.No Discipline / Group Quantity Measured/Instrument

Range / Frequency * CalibrationMeasurementCapability(±)

Remarks

Site Facility

1 ELECTRO-TECHNICAL-ALTERNATINGCURRENT (< 1 GHZ)(Source)

AC Current @ 50 Hz to1 kHz

1 A to 20 A 0.17% to 0.20% Using Calibrator FlukeMPC 5522A by Directmethod

2 ELECTRO-TECHNICAL-ALTERNATINGCURRENT (< 1 GHZ)(Source)

AC Current 50 Hz 20 A to 1000 A 3.19% to 0.7% Using Calibrator FlukeMPC 5522A with 50turns current Coil

3 ELECTRO-TECHNICAL-ALTERNATINGCURRENT (< 1 GHZ)(Source)

AC Current 50 Hz to 1kHz

3 mA to 1 A 0.15% to 0.07% Using Calibrator FlukeMPC 5522A by Directmethod

4 ELECTRO-TECHNICAL-ALTERNATINGCURRENT (< 1 GHZ)(Source)

AC Current 50 Hz to 1kHz

30 µA to 3 mA 1.07% to 0.15% Using Calibrator FlukeMPC 5522A by Directmethod

5 ELECTRO-TECHNICAL- DIRECTCURRENT (Measure)

DC Current 1 A to 10 A 0.086% to 0.193% Using Fluke 8846A61/2 Digital DMM byDirect Method

6 ELECTRO-TECHNICAL- DIRECTCURRENT (Measure)

DC Current 1 mA to 100 mA 0.076% to 0.067% Using Fluke 8846A61/2 Digital DMM byDirect Method

7 ELECTRO-TECHNICAL- DIRECTCURRENT (Measure)

DC Current 10 µA to 1 mA 0.404% to 0.076% Using Fluke 8846A61/2 Digital DMM byDirect Method

This is annexure to 'Certificate of Accreditation' and does not require any signature.

Laboratory Name TRUECAL, PLOT NO 18, FIRST FLOOR, SANTOSHIMA COLONY,SECUNDERABAD, TELANGANA, INDIA

Accreditation Standard ISO/IEC 17025:2017

Certificate Number CC-2230 Page No. : 27 / 44

Validity 14/05/2019 to 13/05/2021 Last Amended on 23/05/2019

Page 29: CALIBRATION ISO/IEC 17025:2017 TRUECAL

S.No Discipline / Group Quantity Measured/Instrument

Range / Frequency * CalibrationMeasurementCapability(±)

Remarks

8 ELECTRO-TECHNICAL- DIRECTCURRENT (Measure)

DC Current 10 A to 800 A 0.94% to 1.38% Using Shunt with DMM

9 ELECTRO-TECHNICAL- DIRECTCURRENT (Measure)

DC Current 100 mA to 1 A 0.067% to 0.086% Using Fluke 8846A61/2 Digital DMM byDirect Method

10 ELECTRO-TECHNICAL- DIRECTCURRENT (Source)

DC Current 1 A to 20 A 0.064% to 0.12% Using Fluke MPC5522A by DirectMethod

11 ELECTRO-TECHNICAL- DIRECTCURRENT (Source)

DC Current 10 µA to 100 µA 0.25% to 0.043% Using Fluke MPC5522A by DirectMethod

12 ELECTRO-TECHNICAL- DIRECTCURRENT (Source)

DC Current 100 µA to 100 mA 0.043% to 0.028% Using Fluke MPC5522A by DirectMethod

13 ELECTRO-TECHNICAL- DIRECTCURRENT (Source)

DC Current 100 A to 1000 A 0.87% to 0.7% Using Fluke MPC5522A with 50 TurnsCurrent Coil

14 ELECTRO-TECHNICAL- DIRECTCURRENT (Source)

DC Current 100 mA to 1 A 0.028% to 0.064% Using Fluke MPC5522A by DirectMethod

15 ELECTRO-TECHNICAL- DIRECTCURRENT (Source)

DC Current 20 A to 100 A 0.12% to 0.87% Using Fluke MPC5522A with 50 turnsCurrent Coil

16 ELECTRO-TECHNICAL-ELECTRICALEQUIPMENT(Measure)

AC Current @ 10 Hz to5 kHz

1 A to 10 A 0.47% Using Fluke 8846A 61/2 DMM by DirectMethod

This is annexure to 'Certificate of Accreditation' and does not require any signature.

Laboratory Name TRUECAL, PLOT NO 18, FIRST FLOOR, SANTOSHIMA COLONY,SECUNDERABAD, TELANGANA, INDIA

Accreditation Standard ISO/IEC 17025:2017

Certificate Number CC-2230 Page No. : 28 / 44

Validity 14/05/2019 to 13/05/2021 Last Amended on 23/05/2019

Page 30: CALIBRATION ISO/IEC 17025:2017 TRUECAL

S.No Discipline / Group Quantity Measured/Instrument

Range / Frequency * CalibrationMeasurementCapability(±)

Remarks

17 ELECTRO-TECHNICAL-ELECTRICALEQUIPMENT(Measure)

AC Current @ 10 Hz to5 kHz

1 mA to 100 mA 0.73% to 0.57% Using 8846A 6 1/2DMM by Direct Method

18 ELECTRO-TECHNICAL-ELECTRICALEQUIPMENT(Measure)

AC Current @ 10 Hz to5 kHz

100 mA to 1 A 0.57% Using Fluke 8846A 61/2 DMM by DirectMethod

19 ELECTRO-TECHNICAL-ELECTRICALEQUIPMENT(Measure)

AC Current @ 10 Hz to5 kHz

30 µA to 1 mA 0.73% to 0.57% Using Fluke 8846A 61/2 DMM by DirectMethod

20 ELECTRO-TECHNICAL-ELECTRICALEQUIPMENT(Measure)

AC Current @ 50 Hz 10 A to 20 A 0.82% Using Shunt with DMM

21 ELECTRO-TECHNICAL-ELECTRICALEQUIPMENT(Measure)

AC Voltage @ 10Hz to20 kHz

1 V to 100 V 0.14% to 0.12% Using Fluke 8846A 61/2 DMM by DirectMethod

22 ELECTRO-TECHNICAL-ELECTRICALEQUIPMENT(Measure)

AC Voltage @ 10Hz to20 kHz

100 mV to 1 V 0.2% to 0.14% Using Fluke 8846A 61/2 DMM by DirectMethod

This is annexure to 'Certificate of Accreditation' and does not require any signature.

Laboratory Name TRUECAL, PLOT NO 18, FIRST FLOOR, SANTOSHIMA COLONY,SECUNDERABAD, TELANGANA, INDIA

Accreditation Standard ISO/IEC 17025:2017

Certificate Number CC-2230 Page No. : 29 / 44

Validity 14/05/2019 to 13/05/2021 Last Amended on 23/05/2019

Page 31: CALIBRATION ISO/IEC 17025:2017 TRUECAL

S.No Discipline / Group Quantity Measured/Instrument

Range / Frequency * CalibrationMeasurementCapability(±)

Remarks

23 ELECTRO-TECHNICAL-ELECTRICALEQUIPMENT(Measure)

AC Voltage @ 10Hz to20 kHz

100 V to 1000 V 0.1% Using Fluke 8846 A 61/2 DMM by DirectMethod

24 ELECTRO-TECHNICAL-ELECTRICALEQUIPMENT(Measure)

AC Voltage @ 10Hz to20 kHz

3 mV to 100 mV 1.9% Usign Fluke 8846A 61/2 DMM by DirectMethod

25 ELECTRO-TECHNICAL-ELECTRICALEQUIPMENT(Measure)

AC Voltage @ 50 Hz 1 kV to 28 kV 3.3% Using Fluke HV PRobe80K 40 with DMM byDirect Method

26 ELECTRO-TECHNICAL-ELECTRICALEQUIPMENT(Measure)

Capacitance 100 Hz 1 µF to 100 µF 0.9% to 0.8% Using LCR Meter byDirect/Comparisonmethod.

27 ELECTRO-TECHNICAL-ELECTRICALEQUIPMENT(Measure)

Capacitance 100 Hz 100 uF to 100 mF 0.8% to 1.2% Using LCR Meter byDirect/Comparisonmethod.

28 ELECTRO-TECHNICAL-ELECTRICALEQUIPMENT(Measure)

Capacitance 1KHz 10 nF to 100 nF 0.7% to 0.6% Using LCR Meter byDirect/Comparisonmethod.

This is annexure to 'Certificate of Accreditation' and does not require any signature.

Laboratory Name TRUECAL, PLOT NO 18, FIRST FLOOR, SANTOSHIMA COLONY,SECUNDERABAD, TELANGANA, INDIA

Accreditation Standard ISO/IEC 17025:2017

Certificate Number CC-2230 Page No. : 30 / 44

Validity 14/05/2019 to 13/05/2021 Last Amended on 23/05/2019

Page 32: CALIBRATION ISO/IEC 17025:2017 TRUECAL

S.No Discipline / Group Quantity Measured/Instrument

Range / Frequency * CalibrationMeasurementCapability(±)

Remarks

29 ELECTRO-TECHNICAL-ELECTRICALEQUIPMENT(Measure)

Capacitance 1KHz 100 nF to 1 µF 0.8% Using LCR meter byDirect/comparisonmethod.

30 ELECTRO-TECHNICAL-ELECTRICALEQUIPMENT(Measure)

Capacitance 1KHz 100 pF to 10 nF 0.75% to 0.7% Using LCR Meter byDirect/ComparisonMethod

31 ELECTRO-TECHNICAL-ELECTRICALEQUIPMENT(Measure)

DC Voltage 1 kV to 40 kV 1.3% to 2.38% Using Fluke HV Probe80K 40 with DMM byDirect Method

32 ELECTRO-TECHNICAL-ELECTRICALEQUIPMENT(Measure)

DC Voltage 1 mV to 1 V 0.47% to 0.004% Using Fluke 8646A61/2 Digit DMM byDirect Methord

33 ELECTRO-TECHNICAL-ELECTRICALEQUIPMENT(Measure)

DC Voltage 1 V to 10 V 0.004% Using Fluke 8846A61/2 Digital DMM byDirect Method

34 ELECTRO-TECHNICAL-ELECTRICALEQUIPMENT(Measure)

DC Voltage 10 V to 100 V 0.004% to 0.0063% Using Fluke 8846A61/2 Digital DMM byDirect Method

This is annexure to 'Certificate of Accreditation' and does not require any signature.

Laboratory Name TRUECAL, PLOT NO 18, FIRST FLOOR, SANTOSHIMA COLONY,SECUNDERABAD, TELANGANA, INDIA

Accreditation Standard ISO/IEC 17025:2017

Certificate Number CC-2230 Page No. : 31 / 44

Validity 14/05/2019 to 13/05/2021 Last Amended on 23/05/2019

Page 33: CALIBRATION ISO/IEC 17025:2017 TRUECAL

S.No Discipline / Group Quantity Measured/Instrument

Range / Frequency * CalibrationMeasurementCapability(±)

Remarks

35 ELECTRO-TECHNICAL-ELECTRICALEQUIPMENT(Measure)

DC Voltage 100 V to 1000 V 0.0064% Using Fluke 8846A61/2 Digital DMM byDirect Method

36 ELECTRO-TECHNICAL-ELECTRICALEQUIPMENT(Measure)

Frequency 1 MHz to 1 GHz 0.0015% Using Counter, EZ FC-7150 V by DirectMethod

37 ELECTRO-TECHNICAL-ELECTRICALEQUIPMENT(Measure)

Frequency 3 Hz to 1 MHz 0.0035% to 0.0012% Using Counter, EZ FC--7150 V by DirectMethod

38 ELECTRO-TECHNICAL-ELECTRICALEQUIPMENT(Measure)

Inductance 1KHz 10 mH to 10 H 0.5% to 1.22% Using Source with LCRMeter byDirect/Comparisonmethod

39 ELECTRO-TECHNICAL-ELECTRICALEQUIPMENT(Measure)

Inductance 1KHz 100 uH to 10 mH 0.91% to 0.504% Using Source with LCRMeter byDirect/Comparisonmethod.

40 ELECTRO-TECHNICAL-ELECTRICALEQUIPMENT(Measure)

Resistance 1 mohm to 1 ohm 0.64% to 0.42% Using micro ohm meterby direct andcomparison method

This is annexure to 'Certificate of Accreditation' and does not require any signature.

Laboratory Name TRUECAL, PLOT NO 18, FIRST FLOOR, SANTOSHIMA COLONY,SECUNDERABAD, TELANGANA, INDIA

Accreditation Standard ISO/IEC 17025:2017

Certificate Number CC-2230 Page No. : 32 / 44

Validity 14/05/2019 to 13/05/2021 Last Amended on 23/05/2019

Page 34: CALIBRATION ISO/IEC 17025:2017 TRUECAL

S.No Discipline / Group Quantity Measured/Instrument

Range / Frequency * CalibrationMeasurementCapability(±)

Remarks

41 ELECTRO-TECHNICAL-ELECTRICALEQUIPMENT(Measure)

Resistance 1 MOhm to 10 MOhm 0.02% to 0.05% Using 8846A 6 1/2DMM using DirectMethod

42 ELECTRO-TECHNICAL-ELECTRICALEQUIPMENT(Measure)

Resistance 1 Ohm to 10 Ohm 0.417% Using Fluke 8846A 61/2 DMM by DirectMethod

43 ELECTRO-TECHNICAL-ELECTRICALEQUIPMENT(Measure)

Resistance 10 kOhm to 100 kOhm 0.013% to 0.01% Using Fluke 8846A 61/2 DMM by DirectMethod

44 ELECTRO-TECHNICAL-ELECTRICALEQUIPMENT(Measure)

Resistance 10 MOhm to 100MOhm

0.05% to 1.07% Using Fluke 8846A 61/2 DMM by DirectMethod

45 ELECTRO-TECHNICAL-ELECTRICALEQUIPMENT(Measure)

Resistance 10 Ohm to 100 Ohm 0.05% to 0.02% Using Fluke 8846A 61/2 DMM by DirectMethod

46 ELECTRO-TECHNICAL-ELECTRICALEQUIPMENT(Measure)

Resistance 100 kOhm to 1 MOhm 0.01% to 0.02% Using Fluke 8846A 81/2 DMM by DirectMethod

This is annexure to 'Certificate of Accreditation' and does not require any signature.

Laboratory Name TRUECAL, PLOT NO 18, FIRST FLOOR, SANTOSHIMA COLONY,SECUNDERABAD, TELANGANA, INDIA

Accreditation Standard ISO/IEC 17025:2017

Certificate Number CC-2230 Page No. : 33 / 44

Validity 14/05/2019 to 13/05/2021 Last Amended on 23/05/2019

Page 35: CALIBRATION ISO/IEC 17025:2017 TRUECAL

S.No Discipline / Group Quantity Measured/Instrument

Range / Frequency * CalibrationMeasurementCapability(±)

Remarks

47 ELECTRO-TECHNICAL-ELECTRICALEQUIPMENT(Measure)

Resistance 100 MOhm to 1 GOhm 1.07% to 4.31% Using 8846A 61/2DMM by Direct Method

48 ELECTRO-TECHNICAL-ELECTRICALEQUIPMENT(Measure)

Resistance 100 Ohm to 10 kOhm 0.02% to 0.013% Using Fluke 8846A 6 1/2 DMM by DirectMethod

49 ELECTRO-TECHNICAL-ELECTRICALEQUIPMENT (Source)

AC Power, 1 phase,50Hz @ 0.2 lag 120Vto 240 V, 0.1A to 20A

2.4 W to 960 W 1.2% Using MPC, Fluke5502A by DirectMethod

50 ELECTRO-TECHNICAL-ELECTRICALEQUIPMENT (Source)

AC Power, 1 phase,50Hz @ 0.5 lag 120Vto 240 V, 0.1A to 20A

6 W to 2.4 kW 0.8% Using MPC Fluke5502A by DirectMethod

51 ELECTRO-TECHNICAL-ELECTRICALEQUIPMENT (Source)

AC Power, 1 Phase,50Hz @ 0.8 Lead 120Vto 240 V, 0.1A to 20A

9.6 W to 3.8 kW 0.6% Using MPC Fluke5502A by DirectMethod

52 ELECTRO-TECHNICAL-ELECTRICALEQUIPMENT (Source)

AC Power, 1 Phase,50Hz @ UPF 120V to240 V, 0.01A to 20A

1.2 W to 4.8 kW 0.6% Using MPC Fluke5502A by DirectMethod

53 ELECTRO-TECHNICAL-ELECTRICALEQUIPMENT (Source)

AC Voltage 10 kHz -100 kHz

10 mV to 100 mV 0.4% to 0.15% Using Fluke MPC5522A by DirectMethod

This is annexure to 'Certificate of Accreditation' and does not require any signature.

Laboratory Name TRUECAL, PLOT NO 18, FIRST FLOOR, SANTOSHIMA COLONY,SECUNDERABAD, TELANGANA, INDIA

Accreditation Standard ISO/IEC 17025:2017

Certificate Number CC-2230 Page No. : 34 / 44

Validity 14/05/2019 to 13/05/2021 Last Amended on 23/05/2019

Page 36: CALIBRATION ISO/IEC 17025:2017 TRUECAL

S.No Discipline / Group Quantity Measured/Instrument

Range / Frequency * CalibrationMeasurementCapability(±)

Remarks

54 ELECTRO-TECHNICAL-ELECTRICALEQUIPMENT (Source)

AC Voltage 10 kHz -100 kHz

100 mV to 1 V 0.96% to 0.1% Using Fluke MPC5522A by DirectMethod

55 ELECTRO-TECHNICAL-ELECTRICALEQUIPMENT (Source)

AC Voltage 10 kHz to100 kHz

1 V to 100 V 0.1% to 0.297% Using Calibrator FlukeMPC 5522A by Directmethod

56 ELECTRO-TECHNICAL-ELECTRICALEQUIPMENT (Source)

AC Voltage 50 Hz to10kHz

100 mV to 100 V 0.03% Using Calibrator FlukeMPC 5522A by Directmethod

57 ELECTRO-TECHNICAL-ELECTRICALEQUIPMENT (Source)

AC Voltage 50 Hz to10kHz

3 mV to 100 mV 0.24% to 0.03% Using Calibrator FlukeMPC 5522A by directmethod

58 ELECTRO-TECHNICAL-ELECTRICALEQUIPMENT (Source)

AC Voltage 50 Hz to1kHz

100 V to 1000 V 0.04% Using Calibrator FlukeMPC 5522A by Directmethod

59 ELECTRO-TECHNICAL-ELECTRICALEQUIPMENT (Source)

DC Power @ 1 V to600 V & 1 mA to 1000A

1 kW to 600 kW 0.6% to 1% Using Fluke 5502A with5500A current coil byDirect method

60 ELECTRO-TECHNICAL-ELECTRICALEQUIPMENT (Source)

DC Power @ 1 V to600 V & 1 mA to 1000A

1 mW to 1 kW 0.1% to 0.6% Using Fluke 5502A with5500A current coil byDirect method

61 ELECTRO-TECHNICAL-ELECTRICALEQUIPMENT (Source)

DC Resistance 1 GOhm to 1 TOhm 1.19% Using standardResistors by DirectMethod

This is annexure to 'Certificate of Accreditation' and does not require any signature.

Laboratory Name TRUECAL, PLOT NO 18, FIRST FLOOR, SANTOSHIMA COLONY,SECUNDERABAD, TELANGANA, INDIA

Accreditation Standard ISO/IEC 17025:2017

Certificate Number CC-2230 Page No. : 35 / 44

Validity 14/05/2019 to 13/05/2021 Last Amended on 23/05/2019

Page 37: CALIBRATION ISO/IEC 17025:2017 TRUECAL

S.No Discipline / Group Quantity Measured/Instrument

Range / Frequency * CalibrationMeasurementCapability(±)

Remarks

62 ELECTRO-TECHNICAL-ELECTRICALEQUIPMENT (Source)

DC Resistance 1 mOhm 0.67% Using StandardResistors by DirectMethod

63 ELECTRO-TECHNICAL-ELECTRICALEQUIPMENT (Source)

DC Resistance 1 MOhm to 100 MOhm 0.004% to 0.06% Using Fluke MPC5522A by DirectMethod

64 ELECTRO-TECHNICAL-ELECTRICALEQUIPMENT (Source)

DC Resistance 1 Ohm to 10 Ohm 0.1% to 0.02% direct Method/Using5522A

65 ELECTRO-TECHNICAL-ELECTRICALEQUIPMENT (Source)

DC Resistance 10 mohm 0.26% Using standardResistors by DirectMethod

66 ELECTRO-TECHNICAL-ELECTRICALEQUIPMENT (Source)

DC Resistance 10 Ohm to 1 MOhm 0.02% to 0.004% Using Fluke MPC5522A by DirectMethod

67 ELECTRO-TECHNICAL-ELECTRICALEQUIPMENT (Source)

DC Resistance 100 MOhm to 1 GOhm 0.06% to 1% Using Fluke MPC5522A by DirectMethod

68 ELECTRO-TECHNICAL-ELECTRICALEQUIPMENT (Source)

DC Resistance 100mOhm 0.26% Using StandardResistors by DirectMethod

69 ELECTRO-TECHNICAL-ELECTRICALEQUIPMENT (Source)

DC Voltage 1 V to 10 V 0.0017% Using Calibrator FlukeMPC 5522A

This is annexure to 'Certificate of Accreditation' and does not require any signature.

Laboratory Name TRUECAL, PLOT NO 18, FIRST FLOOR, SANTOSHIMA COLONY,SECUNDERABAD, TELANGANA, INDIA

Accreditation Standard ISO/IEC 17025:2017

Certificate Number CC-2230 Page No. : 36 / 44

Validity 14/05/2019 to 13/05/2021 Last Amended on 23/05/2019

Page 38: CALIBRATION ISO/IEC 17025:2017 TRUECAL

S.No Discipline / Group Quantity Measured/Instrument

Range / Frequency * CalibrationMeasurementCapability(±)

Remarks

70 ELECTRO-TECHNICAL-ELECTRICALEQUIPMENT (Source)

DC Voltage 10 mV to 1 V 0.043% to 0.0015% Using Calibrator FlukeMC 5522A

71 ELECTRO-TECHNICAL-ELECTRICALEQUIPMENT (Source)

DC Voltage 10 V to 1000 V 0.0015% to 0.0023% Using Calibrator FlukeMPC 5522A

72 ELECTRO-TECHNICAL-ELECTRICALEQUIPMENT (Source)

Frequency 1 Hz to 1 MHz 0.12% to 0.0029% Using Fluke MPC5502A, R&S SignalGenerator SMY 02 byDirect Method

73 ELECTRO-TECHNICAL-ELECTRICALEQUIPMENT (Source)

Frequency 1 MHz to 2 GHz 3.48ppm Using Fluke MPC5502A, R & S SignalGenerator SMY 02 byDirect Method

74 ELECTRO-TECHNICAL-ELECTRICALEQUIPMENT (Source)

Oscilloscope Amplitude 5 mV p-p to 60 (SquareWave Signal) V p-p

0.64% Using Fluke MPC5502A by DirectMethod

75 ELECTRO-TECHNICAL-ELECTRICALEQUIPMENT (Source)

Oscilloscope BandWidth

250 MHz to 2 GHz 6.7% Using Signal GeneratorSMY 02 by DirectMethod

76 ELECTRO-TECHNICAL-ELECTRICALEQUIPMENT (Source)

Oscilloscope BandWidth

50 MHz to 250 MHz 3.0% Using Signal GeneratorSMY 02 by DirectMethod

77 ELECTRO-TECHNICAL-ELECTRICALEQUIPMENT (Source)

Oscilloscope TimeMarker

1 ns to 5 s 0.06% to 0.58% Using Time MarkGenerator TG 201 byDirect Method

This is annexure to 'Certificate of Accreditation' and does not require any signature.

Laboratory Name TRUECAL, PLOT NO 18, FIRST FLOOR, SANTOSHIMA COLONY,SECUNDERABAD, TELANGANA, INDIA

Accreditation Standard ISO/IEC 17025:2017

Certificate Number CC-2230 Page No. : 37 / 44

Validity 14/05/2019 to 13/05/2021 Last Amended on 23/05/2019

Page 39: CALIBRATION ISO/IEC 17025:2017 TRUECAL

S.No Discipline / Group Quantity Measured/Instrument

Range / Frequency * CalibrationMeasurementCapability(±)

Remarks

78 ELECTRO-TECHNICAL-TEMPERATURESIMULATION(Measure)

TemperatureSimulation (Calibrationof temperatureIndicator/Controller/Recorder/Calibrator)RTD

(-)200 °C to 800 °C 0.3°C Using Fluke 5502A inMeasure by DirectMethod

79 ELECTRO-TECHNICAL-TEMPERATURESIMULATION(Measure)

TemperatureSimulation (Calibrationof temperatureIndicator/Controller/Recorder/Calibrator)Thermocouples .NType

(-)200 °C to 1300 °C 0.6°C Using Fluke 5502A inMeasure mode byDirect Method

80 ELECTRO-TECHNICAL-TEMPERATURESIMULATION(Measure)

TemperatureSimulation (Calibrationof temperatureIndicator/Controller/Recorder/Calibrator)Thermocouples B type

600 °C to 1800 °C 0.68°C Using Fluke 5502A inMeasure mode byDirect Method

81 ELECTRO-TECHNICAL-TEMPERATURESIMULATION(Measure)

TemperatureSimulation (Calibrationof temperatureIndicator/Controller/Recorder/Calibrator)Thermocouples E type

(-)200 °C to 1000 °C 0.6°C Using Fluke 5502A inMeasure mode byDirect Method

82 ELECTRO-TECHNICAL-TEMPERATURESIMULATION(Measure)

TemperatureSimulation (Calibrationof temperatureIndicator/Controller/Recorder/Calibrator)Thermocouples J type

(-)200 °C to 1200 °C 0.51°C Using Fluke 5502A inMeasure mode byDirect Method

This is annexure to 'Certificate of Accreditation' and does not require any signature.

Laboratory Name TRUECAL, PLOT NO 18, FIRST FLOOR, SANTOSHIMA COLONY,SECUNDERABAD, TELANGANA, INDIA

Accreditation Standard ISO/IEC 17025:2017

Certificate Number CC-2230 Page No. : 38 / 44

Validity 14/05/2019 to 13/05/2021 Last Amended on 23/05/2019

Page 40: CALIBRATION ISO/IEC 17025:2017 TRUECAL

S.No Discipline / Group Quantity Measured/Instrument

Range / Frequency * CalibrationMeasurementCapability(±)

Remarks

83 ELECTRO-TECHNICAL-TEMPERATURESIMULATION(Measure)

TemperatureSimulation (Calibrationof temperatureIndicator/Controller/Recorder/Calibrator)Thermocouples K type

(-)200 °C to 1350 °C 0.7°C Using Fluke 5502A inMeasure mode byDirect Method

84 ELECTRO-TECHNICAL-TEMPERATURESIMULATION(Measure)

TemperatureSimulation (Calibrationof temperatureIndicator/Controller/Recorder/Calibrator)Thermocouples R type

0 °C to 1750 °C 1.1°C Using Fluke 5502A inMeasure mode byDirect Method

85 ELECTRO-TECHNICAL-TEMPERATURESIMULATION(Measure)

TemperatureSimulation (Calibrationof temperatureIndicator/Controller/Recorder/Calibrator)Thermocouples S type

0 °C to 1750 °C 1.1°C Using Fluke 5502A inMeasure mode byDirect Method

86 ELECTRO-TECHNICAL-TEMPERATURESIMULATION(Measure)

TemperatureSimulation (Calibrationof temperatureIndicator/Controller/Recorder/Calibrator)Thermocouples T type

(-)200 °C to 400 °C 0.7°C Using Fluke 5502A inMeasure mode byDirect Method

87 ELECTRO-TECHNICAL-TEMPERATURESIMULATION (Source)

(Calibration ofTemperature Indicator/controller/Recorder/Calibrator) RTDthermocouples

-200 °C to 800 °C 0.3°C Using Fluke MPC5522A by DirectMethod

88 ELECTRO-TECHNICAL-TEMPERATURESIMULATION (Source)

(Calibrtion ofTemperatureIndicator/Controller/Recorder/Calibrator) J type

(-)200 °C to 1200 °C 0.51°C Using Fluke MPC5522A by DirectMethod

This is annexure to 'Certificate of Accreditation' and does not require any signature.

Laboratory Name TRUECAL, PLOT NO 18, FIRST FLOOR, SANTOSHIMA COLONY,SECUNDERABAD, TELANGANA, INDIA

Accreditation Standard ISO/IEC 17025:2017

Certificate Number CC-2230 Page No. : 39 / 44

Validity 14/05/2019 to 13/05/2021 Last Amended on 23/05/2019

Page 41: CALIBRATION ISO/IEC 17025:2017 TRUECAL

S.No Discipline / Group Quantity Measured/Instrument

Range / Frequency * CalibrationMeasurementCapability(±)

Remarks

89 ELECTRO-TECHNICAL-TEMPERATURESIMULATION (Source)

(Calibrtion ofTemperatureIndicator/Controller/Recorder/Calibrator)Thermocouple B Type

600 °C to 1800 °C 1.03°C Using Fluke MPC5522A by DirectMethod

90 ELECTRO-TECHNICAL-TEMPERATURESIMULATION (Source)

(Calibrtion ofTemperatureIndicator/Controller/Recorder/Calibrator)Thermocouple E Type

(-)200 °C to 1000 °C 0.25°C Using Fluke MPC5522A by DirectMethod

91 ELECTRO-TECHNICAL-TEMPERATURESIMULATION (Source)

(Calibrtion ofTemperatureIndicator/Controller/Recorder/Calibrator)Thermocouple K Type

(-)200 °C to 1350 °C 0.35°C Using Fluke MPC5522A by Directmethod

92 ELECTRO-TECHNICAL-TEMPERATURESIMULATION (Source)

(Calibrtion ofTemperatureIndicator/Controller/Recorder/Calibrator)Thermocouple N Type

(-)200 °C to 1300 °C 0.25°C Using Fluke MPC5522A by DirectMethod

93 ELECTRO-TECHNICAL-TEMPERATURESIMULATION (Source)

(Calibrtion ofTemperatureIndicator/Controller/Recorder/Calibrator)Thermocouple R Type

70 °C to 1750 °C 0.74°C Using Fluke MPC5522A by DirectMethod

94 ELECTRO-TECHNICAL-TEMPERATURESIMULATION (Source)

(Calibrtion ofTemperatureIndicator/Controller/Recorder/Calibrator)Thermocouple S Type

70 °C to 1750 °C 0.25°C Using Fluke MPC5522A by DirectMethod

This is annexure to 'Certificate of Accreditation' and does not require any signature.

Laboratory Name TRUECAL, PLOT NO 18, FIRST FLOOR, SANTOSHIMA COLONY,SECUNDERABAD, TELANGANA, INDIA

Accreditation Standard ISO/IEC 17025:2017

Certificate Number CC-2230 Page No. : 40 / 44

Validity 14/05/2019 to 13/05/2021 Last Amended on 23/05/2019

Page 42: CALIBRATION ISO/IEC 17025:2017 TRUECAL

S.No Discipline / Group Quantity Measured/Instrument

Range / Frequency * CalibrationMeasurementCapability(±)

Remarks

95 ELECTRO-TECHNICAL-TEMPERATURESIMULATION (Source)

(Calibrtion ofTemperatureIndicator/Controller/Recorder/Calibrator)Thermocouple T Type

(-)200 °C to 400 °C 0.4°C Using Fluke MPC5522A by DirectMethod

96 ELECTRO-TECHNICAL- TIME &FREQUENCY(Measure)

Stop Watch 5 s to 86400 s 2% to 0.084% Using Stop Watch byComparison method

97 ELECTRO-TECHNICAL- TIME &FREQUENCY(Measure)

Timer 500 msec to 9000 sec 1.41% to 0.084% Using Timer byComparison Method

98 ELECTRO-TECHNICAL- TIME &FREQUENCY(Measure)

Timer 9000 sec to 86400 sec 0.27% Using Timer byComparison method

99 MECHANICAL-DIMENSION (BASICMEASURINGINSTRUMENT,GAUGE ETC.)

Caliper ( Vernier, Dial,Digital) L.C. 10µm

0 mm to 1000 mm 10.8µm Using Grade “0” GaugeBlocks/Caliper Checkerby comparison methodbased on IS 3651

100 MECHANICAL-DIMENSION (BASICMEASURINGINSTRUMENT,GAUGE ETC.)

Caliper (Vernier, Dial,Digital) L.C. 10µm

0 mm to 600 mm 8.5µm Using grade 0 gaugeblocks / CaliperChecker by comparisonmethod based on IS3651

101 MECHANICAL-DIMENSION (BASICMEASURINGINSTRUMENT,GAUGE ETC.)

Electronic HeightGauge L. C.: 0.1 µm

0 mm to 1000 mm 5.9µm Using Gauge Blocks /Caliper Checker

This is annexure to 'Certificate of Accreditation' and does not require any signature.

Laboratory Name TRUECAL, PLOT NO 18, FIRST FLOOR, SANTOSHIMA COLONY,SECUNDERABAD, TELANGANA, INDIA

Accreditation Standard ISO/IEC 17025:2017

Certificate Number CC-2230 Page No. : 41 / 44

Validity 14/05/2019 to 13/05/2021 Last Amended on 23/05/2019

Page 43: CALIBRATION ISO/IEC 17025:2017 TRUECAL

S.No Discipline / Group Quantity Measured/Instrument

Range / Frequency * CalibrationMeasurementCapability(±)

Remarks

102 MECHANICAL-DIMENSION (BASICMEASURINGINSTRUMENT,GAUGE ETC.)

Surface Plate 4000 mm to 4000 mm 10.8µm Using Precision level(spirit level) bycomparison methodbased on IS 2285, IS7327, IS 12937

103 MECHANICAL-PRESSUREINDICATING DEVICES

Digital/AnalogueVacuum Gauges,Transducers/Transmitters, switches

0 bar to -0.95 bar 1.184% rdg Using PneumaticVacuum ComparatorDigital Pressure GaugePump by comparisonmethod based on DKD-R6-1

104 MECHANICAL-PRESSUREINDICATING DEVICES

Hydraulic PressureDigital/Analoguegauges,Transducers/Transmitters, Switches

0 bar to 1000 bar 0.123% rdg using HydraulicComparator pumpDigital Pressure Gaugeby comparison methodbased on DKD-R6-1.

105 MECHANICAL-PRESSUREINDICATING DEVICES

Pneumatic PressureDigital/AnaloguePressure gauges,Transducers/Transmitters, switches

0 bar to 40 bar 0.156% rdg Using PneumaticPressure ComparatorPump Digital PressureGauge by comparisonbased on DKD-R6-1

106 MECHANICAL-WEIGHING SCALEAND BALANCE

Weighing Balance d:-0.01g

>200 g to 1 kg 0.01g Using StandardWeights of E2 Class asper OIML R – 76-1

107 MECHANICAL-WEIGHING SCALEAND BALANCE

Weighing Balance d:-0.1g

>1 kg to 5 kg 100mg Using StandardWeights of E2 Class asper OIML R – 76-1

108 MECHANICAL-WEIGHING SCALEAND BALANCE

Weighing Balance d:-0.1mg

< Up to 60 g 0.1mg Using StandardWeights of E2 Class asper OIML R – 76-1

This is annexure to 'Certificate of Accreditation' and does not require any signature.

Laboratory Name TRUECAL, PLOT NO 18, FIRST FLOOR, SANTOSHIMA COLONY,SECUNDERABAD, TELANGANA, INDIA

Accreditation Standard ISO/IEC 17025:2017

Certificate Number CC-2230 Page No. : 42 / 44

Validity 14/05/2019 to 13/05/2021 Last Amended on 23/05/2019

Page 44: CALIBRATION ISO/IEC 17025:2017 TRUECAL

S.No Discipline / Group Quantity Measured/Instrument

Range / Frequency * CalibrationMeasurementCapability(±)

Remarks

109 MECHANICAL-WEIGHING SCALEAND BALANCE

Weighing Balance d:-0.1mg

>60 g to 220 g 0.1mg Using StandardWeights of E2 Class asper OIML R – 76-1

110 MECHANICAL-WEIGHING SCALEAND BALANCE

Weighing Balanced:10g

>60 kg to 100 kg 9g Using StandardWeights of F1 class asper OIML R76-1

111 MECHANICAL-WEIGHING SCALEAND BALANCE

Weighing Balance d:1g >5 kg to 60 kg 1g Using StandardWeights of F1 class asper OIML R76-1

112 THERMAL- SPECIFICHEAT & HUMIDITY

Climatic, Temperature& Humidity Chamber @50 %RH

-80 °C to 200 °C 0.72°C Using Temp & Humiditymeter, Std RTD (PT100) & paperlessrecorder by comparisonmethod, RH-Singlepoint, Temp-multi pointcalibration

113 THERMAL- SPECIFICHEAT & HUMIDITY

Climatic, Temperature& Humidity Chamber@10°C to 60°C

10 %RH to 95 %RH 0.83%RH Using Temperature &Humidity Meter, StdRTD (PT100) &Paperless recorder byComparison methodRH-Single point, Temp-Multi point calibration

114 THERMAL-TEMPERATURE

Glass Thermometer (-) 40 °C to 200 °C 0.48°C Using Std. RTD (PT100), 6 ½ digit DMM,Low/High TemperatureOil Bath ByComparison Method

115 THERMAL-TEMPERATURE

RTD, Thermocouple,Temperature Sensors& Digital Thermometer

400 °C to 1000 °C 1.89°C Using Std. S Type T/C,6 ½ digit DMM ,Furnace ByComparison Method

This is annexure to 'Certificate of Accreditation' and does not require any signature.

Laboratory Name TRUECAL, PLOT NO 18, FIRST FLOOR, SANTOSHIMA COLONY,SECUNDERABAD, TELANGANA, INDIA

Accreditation Standard ISO/IEC 17025:2017

Certificate Number CC-2230 Page No. : 43 / 44

Validity 14/05/2019 to 13/05/2021 Last Amended on 23/05/2019

Page 45: CALIBRATION ISO/IEC 17025:2017 TRUECAL

S.No Discipline / Group Quantity Measured/Instrument

Range / Frequency * CalibrationMeasurementCapability(±)

Remarks

116 THERMAL-TEMPERATURE

RTD, Thermocouples,Digital Thermometer &Dial Thermometer0

-40 °C to 400 °C 0.38°C Using Std. RTD (PT100), 6 ½ digit DMM,Low/High TemperatureOil Bath, Furnace ByComparison Method

117 THERMAL-TEMPERATURE

Thermal Chambers/Oven, Water Bath,Furnace

(-) 80 °C to 0 °C 0.72°C Using Std. RTD (Pt100), N type T/C ,Paperless Recorder ByComparison MethodMulti Point (9 Points)Calibration

118 THERMAL-TEMPERATURE

Thermal Chambers/Oven, Water Bath,Furnace

0 °C to 400 °C 0.72°C Using Std. RTD (Pt100), N type T/C ,Paperless Recorder ByComparison MethodMulti Point (9 Points)Calibration

119 THERMAL-TEMPERATURE

Thermal Chambers/Oven, Water Bath,Furnace

400 °C to 1000 °C 2.10°C Using Std. RTD (Pt100), N type T/C ,Paperless Recorder ByComparison MethodMulti Point (9 Points)Calibration

This is annexure to 'Certificate of Accreditation' and does not require any signature.

Laboratory Name TRUECAL, PLOT NO 18, FIRST FLOOR, SANTOSHIMA COLONY,SECUNDERABAD, TELANGANA, INDIA

Accreditation Standard ISO/IEC 17025:2017

Certificate Number CC-2230 Page No. : 44 / 44

Validity 14/05/2019 to 13/05/2021 Last Amended on 23/05/2019