© 2012 Cisco and/or its affiliates. All rights reserved. Presentation_ID Cisco Public Cisco Confidential © 2010 Cisco and/or its affiliates. All rights reserved. 1 Cisco Data Center Training for IBM Changing the Economics of the Data Center Brent Anderson Systems Engineer DataCenter IBM - Global

Upload: christian-silva-espinoza

Post on 13-Jul-2015

587 views

Category:

Technology


30 download

TRANSCRIPT

Page 1: Cisco data center training for ibm

© 2012 Cisco and/or its affiliates. All rights reserved.Presentation_ID Cisco PublicCisco Confidential© 2010 Cisco and/or its affiliates. All rights reserved. 1

Cisco Data Center Training for IBMChanging the Economics of the Data Center

Brent AndersonSystems Engineer – DataCenter

IBM - Global

Page 2: Cisco data center training for ibm

© 2012 Cisco and/or its affiliates. All rights reserved.Presentation_ID Cisco Public

Business Challenges

BudgetConstraints

Security andCompliance

24x7 BusinessBusiness

Agility

Technology Trends

Cloud Data DelugeProliferationof Devices

Energy Efficiency

Page 3: Cisco data center training for ibm

© 2012 Cisco and/or its affiliates. All rights reserved.Presentation_ID Cisco Public

AT&T transfers about 30 Petabytes of data through

its network daily

150 Exabytes global size of “Big Data” in Healthcare, growing

between 1.2 and 2.4 EX / year

Facebook processes 500+ Terabytes of data daily

By 2016, annual Internet traffic will reach 1.3 Zettabytes

$155B Worldwide sensor market in 2011, forecasted to grow to $240B in

2016

450B Business transactions / day over the Internet by 2020

118B E-mails sent daily from a total of 3.4B e-mail accounts;

volume growing to 168B in 2015

6.8B Mobile phones worldwide

Increasing Demands on IT…

Page 4: Cisco data center training for ibm

© 2012 Cisco and/or its affiliates. All rights reserved.Presentation_ID Cisco PublicSource: IBM Global Technology Outlook, 2012

2010 2015

Percentage of Uncertain Data

You are here.

Sensors & Devices

VoIP

Enterprise Data

Social Media

1023

Data Growth: This is only the beginning!

Page 5: Cisco data center training for ibm

© 2012 Cisco and/or its affiliates. All rights reserved.Presentation_ID Cisco Public

Source: IDC, Storage Purchasing Trends Among US Firms, IDC QuickPoll Survey, July 2013, Doc # 243511

© IDC, Visit us at IDC.com and follow us on Twitter: @IDC

2.6

23.8

26.4

28.0

28.3

30.9

42.0

.0 5.0 10.0 15.0 20.0 25.0 30.0 35.0 40.0 45.0

Other

Complexity in managing too many storage product architectures

Quickly fulfilling storage provisioning requests

Time in planning/doing storage migrations/technology refreshes

Time and/or budget to implement advanced storage features

Successfully troubleshooting potentially storage-related problems

Meeting SLAs on performance, availability or recovery

Most Pressing Storage Challenges

% of respondents

Businesses Must AdaptExcluding data growth, Satisfying SLAs is their Top Imperative / Challenge

Page 6: Cisco data center training for ibm

© 2012 Cisco and/or its affiliates. All rights reserved.Presentation_ID Cisco Public

CiscoNexus 5000

CiscoNexus 6000

CiscoNexus 7000

Cisco Nexus 1000V

CiscoNexus 3000

Cisco MDS 9200 Series

Cisco® MDS 9500 Series

Cisco MDS 9100 Series

CiscoNexus 2000

10+ Years of Proven NX-OS Operating System From Hypervisor to Core

Cisco Multi-Protocol Architecture for LAN and SAN

Industry’s Broadest Switching Portfolio

CONSISTENT and SIMPLIFIEDFeatures, Management and Programmability

Cisco Prime Data Center Network Manager (DCNM) Single Point of Management

B22

Page 7: Cisco data center training for ibm

© 2012 Cisco and/or its affiliates. All rights reserved.Presentation_ID Cisco Public

Multi-Protocol Storage Networking

Page 8: Cisco data center training for ibm

© 2011 Cisco and/or its affiliates. All rights reserved. Cisco Confidential 8

FCHigh

Performance Data Center Connectivity

FICONMainframe

Connectivity

FCIPLong Distance

Replication Connectivity

iSCSI-NAS

File and Block Over IP

TCP/IPLAN Connectivity

FCoE

SAN Protocols

LAN Protocols

Page 9: Cisco data center training for ibm

© 2012 Cisco and/or its affiliates. All rights reserved.Presentation_ID Cisco Public

Multi-Protocol Storage Networking

Page 10: Cisco data center training for ibm

© 2012 Cisco and/or its affiliates. All rights reserved.Presentation_ID Cisco Public

Mainframe: LPAR, z/VM, Z-Linux

IBM AIX: LPAR, VIO, P-

Hypervisor, Converged I/O

IBM X86: Hypervisor (ie

Vmware,KVM, HyperV), Blade

Chassis I/O consolidation,

Converged I/O

Cisco MDS with

VSANs, IVR,

NPiV, NPV

Enhanced Ethernet and FCoE FCiP FC

IBM SAN Volume

Controller

Virtualized Disk of DASD

systems

VDISK VDISK

SVC

Multi-Protocol Support

TEST

VSANs

DEV VSAN

Prod. VSAN

WAN

Page 11: Cisco data center training for ibm

© 2012 Cisco and/or its affiliates. All rights reserved.Presentation_ID Cisco Public

Cisco Extends SAN Intelligence to Virtual Server Deployments

Fabric Scalability and PerformanceResilient, high performance fabric to support

large, dense VM environments

Performance Monitoring and TrendingVM-granular management and troubleshooting

Quality of Service (QoS)VM-granular policy provisioning

VSANs Isolate Fault DomainsIncrease availability, simplify

troubleshooting, improve security

Long Distance vMotionSeamless migration of applications

between data centers

Tier 1 Tier 2 Tier 3

SAN Fabric

V V V

NPIVV V V

V V V

V V V

Page 12: Cisco data center training for ibm

© 2012 Cisco and/or its affiliates. All rights reserved.Presentation_ID Cisco Public

The MDS architecture has been designed to meet the following principles:

• High Data Transfer Capability – Provide performance to meet customer requirements

• Predictable Performance – All traffic in chassis has equal and consistent performance no matter traffic ingresses or egresses

• Highly Available – Hardware components and Software features are design for maximum availability

• Data Protection – Protect SAN and End devices from corrupted frames

Page 13: Cisco data center training for ibm

© 2012 Cisco and/or its affiliates. All rights reserved.Presentation_ID Cisco Public

THE OF ANY DIRECTOR

NOW!STORAGE DIRECTOR

INDUSTRY’S MOST

WITHINNOVATIONS

UNMATCHED

INVESTMENT PROTECTION for the Next Decade!

Page 14: Cisco data center training for ibm

© 2012 Cisco and/or its affiliates. All rights reserved.Presentation_ID Cisco Public

SCALEFOR ANY SAN

Up to 384 Line Rate ports with

48x16G FC or 48x10G FCoE

GROWWITHOUT FORKLIFT

1.5-Tbps/slot capacity

3X thePERFORMANCE of any

Director

MDS 9710 Director –Future-Proofing

For Cloud and Massive Amounts of Data

With

Q1 CY14NOW

PRESERVEIT OPERATIONS and KNOWLEDGE

Ease of migration

With NX-OS and DCNM

CONSISTENTOPERATIONS

Page 15: Cisco data center training for ibm

© 2012 Cisco and/or its affiliates. All rights reserved.Presentation_ID Cisco Public

The MDS 9710 is the next generation Fibre Channel Director from Cisco, designed for:

• Highest Scalability in the Industry

‒ 50% more Line-rate 16G FC Ports than competition

• Highest Availability in the Industry

‒ N+1 Fabric Modules protection1 provides zero impact to Application Bandwidth in the event of a fabric card or supervisor card failure

• Investment protection for the next decade

‒ Three times backplane bandwidth2 than competition

1 With optional fourth fabric module installed2 With six fabric modules installed

Page 16: Cisco data center training for ibm

© 2012 Cisco and/or its affiliates. All rights reserved.Presentation_ID Cisco Public

MDS 9710 Chassis

Supervisor Engine

Fabric

Module

48 Port 16G Line Card

Fan Tray

48 Port 10GbE FCoE Module

Page 17: Cisco data center training for ibm

© 2012 Cisco and/or its affiliates. All rights reserved.Presentation_ID Cisco Public

48-Port 16G Fibre Channel Line Card

Cisco 16-Gbps Line Card

Performance 48 x 16 Gbps ports, 768 Gbps

Port Speeds 2, 4, 8, 10 and 16 Gbps Fibre Channel

Optics (sfp+) 2/4/8G FC, 4/8/16G FC, 10G FC, 10GE (FC with 10GE clock)

Port Types F, FL, E, TE, SD, ST

Port Groups Twelve 4-port port-groups

Intelligent Capabilities VSAN, IVR, FC Redirect

Buffer-to-buffer credits Up to 500 per port, 4095 with Enterprise License (510km @ 16G)

Page 18: Cisco data center training for ibm

© 2012 Cisco and/or its affiliates. All rights reserved.Presentation_ID Cisco Public

MDS 9710 PIDs Distance

16G FC SFP+DS-SFP-FC16G-SW

• OM1 -15M, OM2 – 35M

• OM3 – 100M, OM4 – 125M

DS-SFP-FC16G-LW • 10 km

8G FC SFP+

DS-SFP-FC8G-SW• OM2 -100M, OM3 – 150M

• OM4 – 190M

DS-SFP-FC8G-LW • 10 km

DS-SFP-FC8G-ER • 40 km

10G FC SFP+DS-SFP-FC10G-SW

• OM1 – 33m, OM2 – 82 m, OM3 – 300

m

DS-SFP-FC10G-LW • 10 km

10GE SFP+

SFP-10G-SR • 300 m

SFP-10G-LR • 10 km

SFP-10G-ER • 40 km

8G CWDM* DS-CWDM8G-xxxx• 25 km with CWDM Mux and Demux

• 40 km point to point

Page 19: Cisco data center training for ibm

© 2012 Cisco and/or its affiliates. All rights reserved.Presentation_ID Cisco Public1

9© 2010 Cisco and/or its affiliates. All rights reserved. Cisco Confidential

MDS 9710 48-Port FCoE ModuleSeamless Bridge FC SANs to Converged Networks

Use-cases Create FCoE ISLs between N7K/MDS

Bridge Converged Networks to FC SANs

Enabling services such as FCIP to Converged Networks

High-density (48-Port) Line Rate FCoE Module

Supported in any MDS 9700 chassis

BenefitsPreserves existing and continued investments in MDS 9700 FC

Seamless interoperability between all MDS 9700 and Nexus platforms

Preserve existing and continued investments in Fibre Channel

48-port 10-Gbps FCoE Line CardMDS 9700 Chassis

Q2’14

Page 20: Cisco data center training for ibm

© 2012 Cisco and/or its affiliates. All rights reserved.Presentation_ID Cisco Public

Now With FICON SupportMDS 9710

FICON | FCP | CASCADING | VSAN | CUP

Preparing FICON topologies for 16Gbps and 32Gbps channels

Page 21: Cisco data center training for ibm

© 2011 Cisco and/or its affiliates. All rights reserved. Cisco Confidential 21

MDS 9710:

Multi-hop FCoE:

http://www.cisco.com/en/US/solutio

ns/collateral/ns340/ns517/ns224/un

iversity_of_siegen_external_casest

udy_fnl_01_30_13.pdf

http://www.cisco.com/en/US/

solutions/collateral/ns340/ns5

17/ns224/boeing.pdf

http://www.cisco.com/en/US/solutions/col

lateral/ns340/ns517/ns224/NetApp_exter

nal_casestudy_fnl_04_15_13.pdf

http://www.cisco.com/en/US/s

olutions/collateral/ns340/ns51

7/ns224/itochu_cs.pdf

http://www.cisco.com/en/US/solutions/collateral/ns340/

ns517/ns224/mds-linkedin-cs-11_08_13.pdf

http://www.cisco.com/en/US/solutions/collateral/ns3

40/ns517/ns224/molina_cs_10_31_13_final.pdf

Page 22: Cisco data center training for ibm

© 2012 Cisco and/or its affiliates. All rights reserved.Presentation_ID Cisco Public

• Each Fabric Module provides 220 Gbps of actual data bandwidth per slot, equivalent to 256 Gbps of Fibre Channel apparent bandwidth

• Three fabric modules provide 660 Gbps of actual data bandwidth per slot, equivalent to 768 Gbps of Fibre Channel apparent bandwidth

• With six fabric modules, the maximum per slot bandwidth is 1.32 Tbps of actual data bandwidth OR 1.536 Tbps Fibre Channel apparent bandwidth

Page 23: Cisco data center training for ibm

© 2012 Cisco and/or its affiliates. All rights reserved.Presentation_ID Cisco Public

Number of Fabric

Cards

Front panel FC Bandwidth

per Slot/ Total BandwidthFull Line-Rate N+1 Fabric Card Protection

1 256 Gbps No No

2 512 Gbps No No

3 768 Gbps Yes No

4 768 Gbps/1024 Yes Yes

5 1280 YES YES

6 1512 YES YES

Host Port

Line-rate on 48-port 16G FC Module needs only 3 Fabric cards

48 Port 16G FC Module

Switching Bandwidth per fabric card

1

2

3

432Gbps

FC ready

Page 24: Cisco data center training for ibm

© 2012 Cisco and/or its affiliates. All rights reserved.Presentation_ID Cisco Public

0

256

512

768

1024

1280

1536

1 2 3 4 5 6

Band

width-Gb

ps

NumberOfCRModules

PossibleFront-PanelBandwidthPerSlot

0

256

512

768

1024

1280

1536

1 2 3 4 5 6

Band

width-Gb

ps

NumberOfFabricCards

PossibleFront-PanelBandwidthPerSlot

Cisco MDS vs Brocade – 3x Performance

Number Of Fabric

Cards

Front-Panel FC

Bandwidth / Slot

1 256 Gbps

2 512 Gbps

3 768 Gbps

4 1024 Gbps

5 1280 Gbps

6 1536 Gbps

Number Of CR

Modules

Front-Panel FC

Bandwidth / Slot

1 256 Gbps

2 512 Gbps

Cisco MDS

9710

Brocade DCX

8510

0

256

512

768

1024

1280

1536

1 2 3 4 5 6

Band

width-Gb

ps

NumberOfFabricCards

PossibleFront-PanelBandwidthPerSlot

0

256

512

768

1024

1280

1536

1 2 3 4 5 6

Band

width-Gb

ps

NumberOfFabricCards

PossibleFront-PanelBandwidthPerSlot

0

256

512

768

1024

1280

1536

1 2 3 4 5 6

Band

width-Gb

ps

NumberOfFabricCards

PossibleFront-PanelBandwidthPerSlot

0

256

512

768

1024

1280

1536

1 2 3 4 5 6

Band

width-Gb

ps

NumberOfFabricCards

PossibleFront-PanelBandwidthPerSlot

0

256

512

768

1024

1280

1536

1 2 3 4 5 6

Band

width-Gb

ps

NumberOfFabricCards

PossibleFront-PanelBandwidthPerSlot

Future Proof

Growth

0

256

512

768

1024

1280

1536

1 2 3 4 5 6

Band

width-Gb

ps

NumberOfCRModules

PossibleFront-PanelBandwidthPerSlot

Future Proof with MDS 9710 for 32G FC and 40G FCoE

Page 25: Cisco data center training for ibm

© 2012 Cisco and/or its affiliates. All rights reserved.Presentation_ID Cisco Public

3X Less Latency – any port to any port

Page 26: Cisco data center training for ibm

© 2012 Cisco and/or its affiliates. All rights reserved.Presentation_ID Cisco Public

14 RU

MDS 9710Standard

ConfigurationMax Configuration

Line Cards 8

Supervisor Modules 2

Fabric Modules 3 6

Power Supplies 6 8

Fan Trays 3

Chassis Height 24.35” (14 RU)

Chassis Width 17.3”

Chassis Depth 34"

Line-rate 16G Ports/system 384

Airflow Front-to-Back

17.3”

MDS 9710 Director Highlights

Page 27: Cisco data center training for ibm

© 2012 Cisco and/or its affiliates. All rights reserved.Presentation_ID Cisco Public

MDS 9710 Details

Redundant Supervisor

Engines

8 payload slots

(1.5T/slot)

8 3000W AC/DC power

supplies

14RU

3 fan trays

6 fabric modules

(behind fan trays)

RearFront

Front-to-back airflow

32”

Page 28: Cisco data center training for ibm

© 2012 Cisco and/or its affiliates. All rights reserved.Presentation_ID Cisco Public

• New form factor 3000W power supply module

• Autosensing voltage detection

• Both AC and DC power supplies available

• Can mix AC and DC power supplies in same chassis

MDS

Page 29: Cisco data center training for ibm

© 2012 Cisco and/or its affiliates. All rights reserved.Presentation_ID Cisco Public

• Maximum MDS 9710 configuration requires 3 power supplies to operate

• Six power supplies provide grid redundancy, three per power grid

Grid A Grid B

Power Distribution Unit-B

Power Distribution Unit-A

Page 30: Cisco data center training for ibm

© 2012 Cisco and/or its affiliates. All rights reserved.Presentation_ID Cisco Public

• New half-width form factor

• 10/100/1000 Management port, RJ45 Console port, 2 x USB 2.0 ports

SUP2A

MDS 9500

SUP

MDS 9710

Memory 2G 8G

# of Cores 1 4

Clock Speed 1.4 GHz 2.1 GHz

Instruction 32-bit 64-bit

Page 31: Cisco data center training for ibm

© 2012 Cisco and/or its affiliates. All rights reserved.Presentation_ID Cisco Public

MDS 9710 MDS 9513

Maximum Ports Per Chassis384 x 2/4/8/10/16-Gbps FC

384 x 10-Gbps FCoE1

528 x 1/2/4/8/10-Gbps FC

88 x 10-Gbps FCoE

176 x 1-Gbps Ethernet

Line Card Slots 8 11

Supervisor Slots 2 2

Switching Fabric Slots 62 2

Switching Fabric 256 Gbps FC per fabric 128 Gbps FC per fabric

FC Switching Bandwidth 24-Tbps 8.4-Tbps

Physical Dimensions

(H x W x D)24.5 x 17.37 x 34.0 in. 24.5 x 17.37 x 28.0 in.

Physical Dimensions (RU) 14 14

Weight

Chassis - 185 lbs

Power supply - 6 lbs

Fabric module - 11 lbs

Supervisor-1 - 7 lbs

Chassis - 100 lbs

Power supply - 32.5 lbs

Fabric module - 5.75 lbs

Supervisor-2/2A - 7.2 lbs

Airflow Front to back Side to side

Fan Tray Three fan trays at back Front and back fan tray

Page 32: Cisco data center training for ibm

© 2012 Cisco and/or its affiliates. All rights reserved.Presentation_ID Cisco Public

MDS 9000 Portfolio

Gen-1 (2Gb)

Supervisor-1

MDS 9506 & 9509

IPS-8

FC-32

FC-16

SSM

MPS -14/2

MDS 9216 & 9216i

Gen-2 (4Gb)

12/24/48-port 4Gb FC

MSM-18/4

Supervisor-2/2A 4-port 10Gb FC

MDS 9222i

MDS 9513

MDS 9124 & 9134

Gen-3 (8Gb)

24/48-port 8Gb FC

4/44-port 8Gb FC

SSN-16

Fabric-2

MDS 9148

EOLGen-4

8Gb FLR

4/44-port 8Gb FC

SSN-16

Fabric-3

MDS 9148

32-port 8Gb FLR FC

48-port 8Gb FC

Fabric-3

EOS

Page 33: Cisco data center training for ibm

Cisco Confidential© 2013 Cisco and/or its affiliates. All rights reserved. 34

Page 34: Cisco data center training for ibm

© 2012 Cisco and/or its affiliates. All rights reserved.Presentation_ID Cisco Public

Ethernet1 2 3 4 5 6 7 8

MDS 9250i Multiservice Fabric SwitchNext-Gen Storage Services Platform for Unified FabricFCiP | FC | FICON | iSCSI | FCoE

Features

Line Rate Performance for

• 16G FC, 10GE FCoE, 10GE FCIP, FICON, iSCSI

Rich set of Storage Services for FC and FCoE SANs

• FCIP, IO Accelerator (IOA), Data Mobility Migration (DMM),

Integrated Management via Data Center Network Manager (DCNM)

Benefits

Single Platform for deploying Storage Services across FC and FCoE Storage Area Networks (SANs)

• High-Bandwidth SAN Extension across MAN/WAN

• Migrate Data between FC and FCoE arrays

MDS 9250i

40 Ports 16G FC 8 Ports 10GE FCoE

2 Ports 10GE FCIP/iSCSI 1+1 Redundant Fans

2+1 Redundant Power Supplies

Page 35: Cisco data center training for ibm

© 2012 Cisco and/or its affiliates. All rights reserved.Presentation_ID Cisco Public

DATA MIGRATION

Migrate Data between

Heterogenous Arrays

BUSINESS CONTINUITY/DISASTER RECOVERY

16G FIBRE CHANNEL SWITCH FC TO FCOE GATEWAY

MDS 9250i

IP WAN

MDS 9250i

NexusMDS

9710

10G FCIP

FC

MDS 9250i

DWDM/

SONET

Optical

MAN

FC

FCoE

MDS 9250i

FCoE

FC FCoE

Nexus

Nexus

Page 36: Cisco data center training for ibm

© 2012 Cisco and/or its affiliates. All rights reserved.Presentation_ID Cisco Public

• SAN Extension is an integral component of SAN Business Solutions:

‒ Disaster Recovery – Protecting Data Through Offsite Data Replication and Backup

‒ Business Continuance – Restoration of Business After a Failure

‒ Business Resilience – Continued Operation of Business During a Failure

‒ Cloud Storage – Leveraging the Cloud for Data Storage

• Solution dependent on available DCI network and the customer business requirements (RPO, RTO)

Page 37: Cisco data center training for ibm

© 2012 Cisco and/or its affiliates. All rights reserved.Presentation_ID Cisco Public

• SAN Extension solutions typically divided into the following categories:

Solution Solution FC FCoE FCIP

Dark FiberReplication -

Synchronous1, 2, 4, 8, 10, 16G 10GE 1, 10GE

CWDMReplication -

Synchronous1, 2, 4, 8 10GE 1, 10GE

DWDMReplication -

Synchronous1, 2, 4, 8, 10G 10GE 1, 10GE

SONET/SDH

Replication –

Synchronous /

Asynchronous,

Backup

1, 2, 4, 8, 10G NA 1, 10GE

FCIP

Replication –

Asynchronous,

Backup

NA NA 1, 10GE

Page 38: Cisco data center training for ibm

© 2012 Cisco and/or its affiliates. All rights reserved.Presentation_ID Cisco Public

• SAN Extension distance is limited by two separate factors

‒ Physical Layer – How far can the optics transmit or how far does the interconnect go (dependencies on cable type and speed)?

‒ SW optics – < 1 km,

‒ MR optics – up to 4 km

‒ LW optics – up to 10 km

‒ ER optics – up to 40 km

‒ CWDM/DWDM optics – up to 40 km point-to-point

‒ Flow control – How many frames can I have in flight?

‒ FC – Determined by BB credits

‒ FCoE – Determined by interface buffers

‒ FCIP – Determined by the TCP window size

• It is the combination of these two factors that determines how far a FC solution can be deployed

Page 39: Cisco data center training for ibm

Cisco Confidential© 2013 Cisco and/or its affiliates. All rights reserved. 40

Cisco Prime

Data Center Network Manager

Page 40: Cisco data center training for ibm

© 2012 Cisco and/or its affiliates. All rights reserved.Presentation_ID Cisco Public4141

• Device level configuration via Cisco CLI or Device Manager application

• Initial product configuration• VSAN configuration• Port configuration

• Manager SNMP security access• Manage alarms, events and notifications

• View chassis, module, port status

• Fabric wide configuration via DCNM SAN (Java)

• Fabric wide configuration of port channels, FCIP, VSANs, etc• Topology view

• Event monitoring• Fabric trouble shooting tools

• Wizard-based fabric provisioning: verify changes before execution and reduce chances for human error

• Real-time event forwarding for proactive storage network management and reduced response time

MDS Management

IBM System Networking

Page 41: Cisco data center training for ibm

© 2012 Cisco and/or its affiliates. All rights reserved.Presentation_ID Cisco Public42

The Summary Dashboard is configurable to display choices include: Health, Inventory, Traffic Flows, Connectivity, Used/Remaining Capacity

Cisco Data Center Network Manager AdvancedKey Feature: Dynamic Dashboards

IBM System Networking

Page 42: Cisco data center training for ibm

© 2012 Cisco and/or its affiliates. All rights reserved.Presentation_ID Cisco Public43

• VMpath

VM connectivity to network and storage

• Standard & Custom Reports

• Provisioning NX-OS features

• Dynamic Topology Views

• Image Management

• Configuration Backup/Restore

• Rule-based event filtering and forwarding

• Threshold Alerting

• Change Tracking and RBAC

Cisco Data Center Network Manager AdvancedFeature Support and User Interface

IBM System Networking

Page 43: Cisco data center training for ibm

© 2012 Cisco and/or its affiliates. All rights reserved.Presentation_ID Cisco Public44

VMpath: End to End Performance Management

• Troubleshoot Performance across virtualized compute and network domains

• Understand the Impact of the path outage along with event description

• Understand behavior of your applications over a period of time

VM SERVERNEXUSSWITCH

TRUNK / ISLSTORAGE

PORTMDS

SWITCH

IBM System Networking

Page 44: Cisco data center training for ibm

© 2012 Cisco and/or its affiliates. All rights reserved.Presentation_ID Cisco Public

Click here for CLI Access

Select switches to open and common

credential

Page 45: Cisco data center training for ibm

Reduces risk when upgrading

switch and storage arrays

Prevents outages due to missing

redundancy

Reduces time to migrate and

deploy infrastructure

Page 46: Cisco data center training for ibm

© 2012 Cisco and/or its affiliates. All rights reserved.Presentation_ID Cisco Public

SAN Host Path Redundancy Analysis

What it looks for

• Identifies non-redundant hosts

• Exceptions policy for single path hosts

• Optional storage array LUN check

• Fix recommendation

• Description of violation

• Supports FC and FCoE

• Runs every 24 hours or on demand

MDSN77

N5K

STORAGE

SERVER

VMWARE

N5K MDS

STORAGE

MDS

MDS

MDS

Missing Zone

Time

Port Down on redundant fabric

VSAN mismatch

VSAN segmentation

LUN visible through a single fabric only

MDS

MDS

Page 47: Cisco data center training for ibm

© 2013 Cisco and/or its affiliates. All rights reserved. Cisco Confidential 51

• The snooze feature will prevent forwarding of configured alerts

during specified time range.

Page 48: Cisco data center training for ibm

© 2012 Cisco and/or its affiliates. All rights reserved.Presentation_ID Cisco Public

• Scaling work being done in 6.2(7) and beyond allows for greater flexibility in large scale SANs, especially for NPV environments

Feature 6.1(1) - 6.2(5) 6.2(7)

Phase-1

Gibraltar (7.x)

Phase-2

Flogi per line card 500 1000 1000

Flogi per NPIV core switch 2500 4000 4000

Zone members 16000 30000 30000

Zones 8000 16000 16000

Logins per fabric 10000 20000 20000

FCNS entries per fabric 10000 20000 20000

No of Domains 60 60 80

NPV switches/ NPIV Core Switch 105 105 105

Device Alias 8000 8000 20000

No. of VSANs per fabric 80 80 80

Page 49: Cisco data center training for ibm

© 2012 Cisco and/or its affiliates. All rights reserved.Presentation_ID Cisco Public

Fault Tolerance in SANs

Addressing Misbehaving Devices

• Port Guard – Shutdown the link after multiple errors

Configurable thresholds (number of errors and duration)

• Slow Drain Devices – Detect, Notify, Recover

Detect - Monitor buffer credits and ASIC queues

Notify - SNMP traps and System Logs

Recover – Configurable multi-step recovery options

Disable the port right away

Attempt to recover through timeouts and frame-drops first

Misbehaving HBA

Affected Host

Page 50: Cisco data center training for ibm

© 2012 Cisco and/or its affiliates. All rights reserved.Presentation_ID Cisco Public

Port-Guard The Link failure can happen for any of the following reasons.

- Cable cut (NOS/LOS)

- In case of F ports, the connected device has rebooted

- In case of ISL, the connected line card has rebooted

- Too many bit errors due to bad SFP/Cable etc.

- B2B buffer overflow condition

- Hardware Recoverable errors

Once the condition is hit the link will be down with the ‘Error disabled - port down due to link failure’ as the reason. This reason will also be displayed in the ‘show interface’ command.

User will need to perform the following to bring the link up again.

- ‘shut’ command followed by ‘no shut’ command

- Note: By default, irrespective of if this feature is enabled or not, we shut down the port if the switch receives too many invalid flogi’s from a host.

Page 51: Cisco data center training for ibm

© 2012 Cisco and/or its affiliates. All rights reserved.Presentation_ID Cisco Public

Port-Guard config using Device Manager

Page 52: Cisco data center training for ibm

© 2012 Cisco and/or its affiliates. All rights reserved.Presentation_ID Cisco Public

Cisco Nexus B22 Fabric Extender for IBM

• Extends FEX connectivity into blade chassis

• Cisco Nexus 5500/6000 Switch is a single management point for all the blade chassis I/O modules

• End-to-end FCoE support

• 50% decrease in blade chassis I/O modules

• 66% decrease in blade management points

• Blade & rack networking consistency

• Increased network resiliency

FEATURES

BENEFITS:

Cisco Nexus B22

IBM

Page 53: Cisco data center training for ibm

© 2012 Cisco and/or its affiliates. All rights reserved.Presentation_ID Cisco Public

Cisco Nexus 2000 Series Fabric Extender

+

Cisco Nexus Parent Switch

Nexus 2000 Fabric Extender

Virtual Modular System

=

Page 54: Cisco data center training for ibm

© 2012 Cisco and/or its affiliates. All rights reserved.Presentation_ID Cisco Public 6565

Nexus 5500 Series

FEX parent switch upgrade

Enhances POD with Layer 3 Intelligence

Enables Cisco Fabric Path

50% Reduction in Latency

40G Ready (future)

Scales to 1,000 hosts and 4K VLANs

Nexus 5500 + Nexus 2000

Page 55: Cisco data center training for ibm

© 2012 Cisco and/or its affiliates. All rights reserved.Presentation_ID Cisco Public

Key Feature Cutlass

Number of Ports 14 Internal server ports

8 External FET or SFP+ ports

Speed 1/10Gb internally; 10 Gb externally

Chassis management through I2C only; switch

management through upstream Top of Rack Switch

No CLI

No Configuration

No Ethernet NIC

Minimal CMM interaction

No apparent FSM interaction

No SNMP or MIB support (though Director and FSM

can interrogate CMM and upstream switch through

standard Nexus supported interfaces)

Max Computed Power 65.05w

FEX details

Page 56: Cisco data center training for ibm

© 2012 Cisco and/or its affiliates. All rights reserved.Presentation_ID Cisco Public

Part Number information

The part number for the B22 Fabric Extender includes the following items:

• One Cisco Nexus B22 Fabric Extender

• Sixteen Cisco Fabric Extender Transceivers (Cisco part number FET-10G included only in 94Y5355)

• Important Notices Flyer

• Technical Update Flyer

• Warranty Flyer

• CRU/FRU Flyer

• Documentation CD-ROM

Note: Cisco Nexus B22 Fabric Extender, part number 94Y5350, comes without SFP or SFP+ (small form-

factor pluggable plus) transceivers or cables. They must be ordered separately.

Sold Exclusively by

IBM and its Partners

Page 57: Cisco data center training for ibm

© 2012 Cisco and/or its affiliates. All rights reserved.Presentation_ID Cisco Public

Fabric Extender Connectivity Options

Fabric Extender Transceiver (FET)

• Cost-effective N5K->N2K interconnect

• SFP+ form-factor

• Reach of 100M (OM3 fiber)

• Incompatible with SR optics

• Used for N2K interconnect only

• Low power & latency

Single Reach (SR)

Long Reach (LR) Direct Attached Copper (Twinax)

Fabric Extender Transceiver (FET)

Page 58: Cisco data center training for ibm

© 2012 Cisco and/or its affiliates. All rights reserved.Presentation_ID Cisco Public

Supported Adapters

* The Embedded 10Gb Virtual Fabric Adapter is included in models of the x240 with model numbers of the form x2x.

Page 59: Cisco data center training for ibm

© 2012 Cisco and/or its affiliates. All rights reserved.Presentation_ID Cisco Public

Connecting to Cisco network - Customer already owns Nexus ToR

LOM or CN4054

(pNIC, vNIC mode)

V7000

B22 Cisco FEX

Key value:

• Integrated Virtual Fabric and FCoE on compute node

• Cisco FEX in chassis - unmanaged

• Connects to existing or new Cisco network.

Black line is FCOE

Red line is Fibre Channel

Yellow line is Ethernet

Cisco

SAN

Nexus 55XX

Nexus 55XX

Adapter Integrated Switch FCoE Top Of Rack Switch SAN Switch Storage Target OS levels

LOM & CN4054 4-port adapter

(BE3) pNIC and vNIC modes

B22 Cisco FEX Nexus 5548 / 5596 Cisco SAN FC: V7000, SVC, DSXXX Win2008 R2SP1, ESX 5.0 U1,

RHEL 6.3

Nexus7K

Page 60: Cisco data center training for ibm

© 2012 Cisco and/or its affiliates. All rights reserved.Presentation_ID Cisco Public

FEX Parent - Cisco Nexus 5548UP & 5596UP

Mgmt 0, Console,

USB

Redundant Fan

Modules

Redundant 750W AC

Power Supplies

• Fixed Unified Ports

• Line Rate

• 1/10GE & FCoE

• 8/4/2/1 Native FC

Expansion Module

• 16p Unified Ports

Back of the Switch

Front to Back AirflowFront of the

Switch

Page 61: Cisco data center training for ibm

© 2012 Cisco and/or its affiliates. All rights reserved.Presentation_ID Cisco Public

FEX Parent - Nexus 6004 Chassis

12 QSFP ports

Expansion Module48 Fixed QSFP Interfaces

4RU

30”

Page 62: Cisco data center training for ibm

© 2012 Cisco and/or its affiliates. All rights reserved.Presentation_ID Cisco Public

FEX cable support plan – IBM cables

Page 63: Cisco data center training for ibm

© 2012 Cisco and/or its affiliates. All rights reserved.Presentation_ID Cisco Public

FEX cable support plan – Cisco cables

Page 64: Cisco data center training for ibm

© 2012 Cisco and/or its affiliates. All rights reserved.Presentation_ID Cisco Public

IBM and Cisco: How to design a state-of-the art data center and

networking infrastructure combining Cisco and IBM solutions

IBM and Cisco Building Blocks for the Data Center

Physical Access Layer Evolution

Cisco Virtual Networking Solutions

Convergence of LAN and SAN

DCN Management and Automation

SDN and Cisco ONE

Reference Designs for Small, Medium and Large

DCs

Link to Redbook:

http://www.redbooks.ibm.com/redpieces/abstracts/sg248105.html?Open

75

Page 65: Cisco data center training for ibm

© 2012 Cisco and/or its affiliates. All rights reserved.Presentation_ID Cisco Public

• Hardware

‒ 48-port 16G FC fixed fabric switch

‒ 1RU with field replaceable redundant power supplies and fans, with B2F air flow

‒ 10/100/1000 Ethernet, USB, and serial console for management access

‒ Base configuration of 12, 24, or 48 active ports

• Software

‒ NX-OS SAN 7.x release

• Licenses

‒ 12-port port upgrade license

Q3CY14

Page 66: Cisco data center training for ibm

© 2011 Cisco and/or its affiliates. All rights reserved. Cisco Confidential 78

6.2(1)Scope: MDS-9710

6.2(9)Scope: 16G

1RU, FC Scale, 9710 CTS

6.2(5) Scope: MDS

9250i, Pathtrace

6.2(3)Scope: bug fix release, plus

FCR, CLI

* Not engineering committed

Helsinki*Scope: 9706, OnePK, TBD

6.2(7)Scope: FCoE on 9710, FC Scale,

16G FEC

6.2(2) FCoE: F2-NG (N7710/N7718)

6.2(6)FCoE with Ethernet

vPC

Gibraltar 7.0(2)FCoE over FEX on F2,

FCoE on F2E (N7706) , FCoE Scale, FCoE over FabricPath Spine

Nexus 7000Helsinki*FCoE on F3 (10G/40G)

5.2(8c)Scope: Bug fixes

5.2(8a)Scope: Bug fixes

5.2(8b)Scope: Bug fixesMDS

Q3 CY13 Q4 CY13 Q1 CY14 Q2 CY14 Q4CY14Q3 CY14

6.0(2)N1(1)N6004 w/ 12p 10/40GE LEM, FCoE 10G Base-T

(N5596T), N2248PQ

Illuka (Maint.) 7.0(1)N1(1)20P 8G/10GE UP LEM (N6004), Nexus 56128, Nexus 5672UP, FCoE

over FabricPath

6.0(2)N1(2)N6001P, iSCSI

TLV (N5x)

Illuka (Plus)* 7.1.x16G FC GEM (N6K)

FCoE over DFA (Leaf/Spine), 4-port VFC, IVR, Smart Zoning, FCoE with

Switch-to-Switch vPC, FCoE Slow Drain (N6K)

Illuka 7.0(0)N1(1)FC Slow Drain and Port Monitor

(N55xx), FCoE Slow Drain (N55xx, N55xx w/ FEX), VFC

Scale, iSCSI TLV (N6K)

Nexus Fixed

Q2 CY13Q1 CY13

Page 67: Cisco data center training for ibm

© 2012 Cisco and/or its affiliates. All rights reserved.Presentation_ID Cisco Public

New White Papers

Large Scale Design Best Practices

Using Cisco MDS 9500 Series and

9710 Multilayer Directors

Large Scale Design Best

Practices Using Cisco 9710

Multilayer Directors

Slow Drain Device Detection

and Congestion Avoidance

Design SANs with Detailed Best Practices Guides