comparison of cooling services at barrel end description sct barrel upgrade id barrel one end one...

3
Comparison of cooling services at barrel end SCT Barrel Up one end Total number of staves/rows 176 Staves/rows serviced off one end 88 use sample of 88 Length of stave/row wrt barrel length full length half length Total exhaust pipes off barrel end 22 88 Total input pipes off barrel end 44 88 Number of pipes on each stave/row 1 2 Staves/rows served by 1 exhaust pipe 4 1 Staves/rows served by 1 input pipe 2 1 Cooling ‘unit’ serves: alternate 4 rows integrated with stave Location of exhaust manifold inside barrel end no manifolding Number of pipes to manifold 2 pipes go to 1

Upload: marsha-hunter

Post on 24-Dec-2015

216 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Comparison of cooling services at barrel end Description SCT Barrel Upgrade ID barrel one end one end Total number of staves/rows 176 Staves/rows serviced

Comparison of cooling services at barrel endDescription SCT Barrel Upgrade ID barrel one end one end

Total number of staves/rows 176 Staves/rows serviced off one end 88 use sample of 88 Length of stave/row wrt barrel length full length half lengthTotal exhaust pipes off barrel end 22 88Total input pipes off barrel end 44 88Number of pipes on each stave/row 1 2Staves/rows served by 1 exhaust pipe 4 1Staves/rows served by 1 input pipe 2 1Cooling ‘unit’ serves: alternate 4 rows integrated with staveLocation of exhaust manifold inside barrel end no manifoldingNumber of pipes to manifold 2 pipes go to 1 “Length of manifold approx. 60mm “Material exhaust spiders Cu ssMaterial input capillary CuNi ssNumber exhaust connectors 22 88Number input connectors 44 88Extra pipe on stave/row > SCT x 2Extra exhaust pipe on barrel end > SCT x 4Extra pipe outside barrel end > SCT x 3

Page 2: Comparison of cooling services at barrel end Description SCT Barrel Upgrade ID barrel one end one end Total number of staves/rows 176 Staves/rows serviced

modules

staves

Current SCT Barrel cooling layout for 4 rows – 1 manifold.

Upgrade SCT Barrel cooling layout for 4 rows – no manifolds

Schematic illustrating comparative occupation of cooling pipes/manifolds/connectorson one barrel end flange – overlap of modules not shown, equivalent active area – 4 full length rows on ‘old’ compared with half-length ‘new’ (very approx.) Not to scale.

end

flang

e

cooling direction

Page 3: Comparison of cooling services at barrel end Description SCT Barrel Upgrade ID barrel one end one end Total number of staves/rows 176 Staves/rows serviced

SCT BARREL END…..22 Cu cooling pipe spiders

Wait and see……if this scenario leads to a 10% loss in the EC thenUpgrade will probably lose 40% in the EC even without cooling connectors.