conergy cis 1200 manufactured by bosch outstanding peak system efficiency of up to 98.2 % ... the...

8
CONERGY CIS 1200 Manufactured By Bosch QUALITY C O N E R G Y M A D E I N G E R M A N Y O F F E R S

Upload: hanhan

Post on 30-Mar-2018

222 views

Category:

Documents


1 download

TRANSCRIPT

CONERGY CIS 1200Manufactured By Bosch

Q U A L I T YCO

N E RG Y

MA D E I N G E R

MA

NY

O F F E R S

01

CONERGYCIS 1200The innovative central inverter station (CIS series) by CONERGY are manufactured by world

leading manufacturer of energy solutions BOSCH Power Tech. GmbH . It is built to provide fully

integrated solution for large PV power plants. It consist of central inverter of conergy IPG series ,

high performance voltage transformer , conergy smart connect and innovative Conergy Vision Box

(with iPhone App)

High yields in practical use

• Outstanding peak system efficiency of up to 98.2 %

• High-quality equipment with latest inverter

technology from the Flextech IPG C Series

Permanently reliable operation and long service life

• Complete station type tested

• Optimised ventilation concept for reliable operation

Planning flexibility

• Modular design: available in the output classes 1.2 MW, staggered in 100-kW steps

• Complies with all relevant European standards, directives and guidelines (including German

Medium-Voltage Guideline)

Easy to install

• Fully integrated inverter station including medium-voltage transformer, ventilation and

monitoring system

• Minimal planning, transport and installation effort

Extremely efficient operation

• Outstanding peak efficiency factor of

up to 98.8 % for the highest possible

yields

• Optimum energy yields also possible in

low-light conditions

• Remote diagnosis via Internet using the

integrated web server

Reliable over a long service life

• Comprehensive service agreements

and maintenance contracts for complete

investment security

• High-quality component selection

ensures long-term high reliability

w w w . fl e x t e c h - e n e r g y . d e02

The Bosch manufactured Conergy CIS ensures the operators of PV plants maximum return throughout the

life. The central inverters of Conergy comply with all European Legal Norms and standards, such as German

“Medium Voltage Directives “. The entire inverter stations are design approved and comply in dimension and

layout with European Standard Requirements.

Custom tailored final product thanks to flexible combinationIn the station made of weatherproof concrete, the

new generation of Flextech IPG C central inverters

are used. Flextech will offer the complete solution

with a rated output of 1.2 MW. As a result, the

customer is provided with a final product exactly

tailored to meet its needs and requirements – with a

maximum performance and top reliability thanks to

exactly matched system technology.

Preconfigured complete systemThe interconnections of the individual components

have been pre-tested without exception.

Connections, links, the comprehensive protection

system and the certified ventilation and filter

concept are ready for immediate use. Local planning

and installation effort and expense are therefore

reduced to a fraction with the Flextech complete

solution.

Flextech CISs confirm with European directivesLike the new Flextech IPG C central inverters, the

central inverter station also complies with all

currently applicable European standards and

directives for smooth commissioning.

CONERGY CIS 1200

Every solar energy system does not supply power to the grid for approx. 50 % of its service life, for example at night.

In 20 years, this adds up to approx. 88,000 hours.

However, the transformer stations do consume power in this time; the electricity meter turns backwards. The

highly efficient amorphous transformer stations used by Conergy reduce this loss by approx. 60 %.

03

More than 60 % electricitysavings due to the use ofamorphous transformer stations*a

The Flextech accessories.For maximum efficiencyin the solar energy system.

Flextech VisionBox.The Flextech VisionBox is the

professional system-monitoring

system with extensive functions for

data analysis, fault diagnosis and

automatic alarms.

• Ideal for solar energy systems

from 3 kW up to 18 MW

• Monitors up to 60 Conergy IPG

inverters and/or Conergy

SmartConnect

• Reports faults automatically via

VVthe display and LEDs. You can

also choose to have the alarms sent

via SMS, fax or e-mail

• Offers worldwide access to all

data via PC or Smartphone using

the web portal www.sunreader.de

• Has a standard USB connection

for simple data transfer and

software updates The Conergy

VisionBox app for your iPhone can

now be used to monitor your

system easily while you are on the

move.

Conergy SmartConnect.The Conergy SmartConnect brings

together up to eight module strings,

each with a max. of 20 A, and routes

them securely to the Conergy IPG

C or to Conergy CIS.

The Conergy SmartConnect also

enables accurate and clear

monitoring of strings using a safety

concept that is adapted to PV

technology.

• Simple module string connection

to the inverter with integrated

monitoring

• Transmits the operating data

continuously to the Conergy

VisionBox (accessory

Conergy GridControl.Conergy GridControl is the

interface between the solar power

station and the grid operator. With

this interface, the grid operator can

easily remotely control the output

of photovoltaic systems with more

than 100 kW, as required.

• Processes both analogue and

digital control signals from the grid

operator

• The output interventions made

by the grid operator can be

documented in the logbook of

Conergy VisionBox

w w w . fl e x t e c h - e n e r g y . d e04

CONERGY CIS 1200Technical Specifications

DSFSA

w w w . fl e x t e c h - e n e r g y . d e04

CONERGY CIS 1200

Input values (PV generator)

Max. DC input voltage

Minimum DC input voltage (VDCmin)

Maximum MPP voltage (VMPPmax)

Minimum MPP voltage (VMPPmin)

Max. input current (IPCmax)

Number of inputs

Fuse per input

Connection design

Coupling box

1,000 V

530 V

800 V

530 V

590 A (IPG 300C)/400 A (IPG 200C)

4 per inverter

175 A–250 A (adjustable)

M12 screws to copper rail

Integrated in inverter

Output data (grid)

Rated grid voltage (VAC, r)

Rated frequency (fr)

Maximum frequency (fmax)

Minimum frequency (fmin)

Power factor (cos ϕ)

Distortion factor

Connection design

20 kV with tappings 2x +/-2,5 %

50 Hz

52 Hz

47.5 Hz

Adjustable 0.7 inductive to 0.7 capacitive

(at rated capacity) ≤ 2 %

Connection type A acc. EN 50180 and EN 50181, external cone 250 A

Auxiliary supply

Required auxiliary power supply

Required series fuse

Supply for customer devices

Optional auxiliary transformer

400 V/50 Hz/14 kVA/3-phase with N/TN grid

C20 A, 3-phases

B16 A/230 V/50 Hz with RCD (one connection per inverter)

Dry transformer 400 V/14 kVA

Cooling

Cooling type Air cooling,

Type of air filter

Filter surface

Max. counter-pressure with additional station conversion

individual thermally controlled fans

Pocket filter in accordance with G3 EN 779

40 m²

50 Pa in total for feed and exhaust air

Environmental / ambient conditions

Temperature range 1

Maximum temperature for permanent rated capacity 1

Relative humidity (non-condensing)

Installation altitude above sea level

–20° C to +50° C

+50 °C

≤ 95 %

≤ 2,000 m

Safety / protective equipment

Protection type

Earth fault monitoring

Overvoltage arrester

Decoupling of PV generator from the grid

IP 54 in accordance with EN 60529

Yes, response configurable

Integrated in inverter: DC side Type II, mains side Type I in

accordance with IEC 61643-1

Galvanic isolation by means of the medium-voltage transformer

Medium-voltage transformer

Construction

Cooling

Filling

Tappings

Oil transformer, hermetically sealed

ONAN

Dry and vented mineral oil

21.0 kV/20.5 kV/20 kV/19.5 kV/19 kV

Technical Specifications

DIN EN 61000-6-4:2007-09DIN EN 61000-6-2:2006-03DIN EN 50178:1998-04VDE 0126-1-1, D 5940 Ed 2.2, RD 664, RD 1663, EN 50438:2007,ÖVE E 2750

Inverter

Transient emissions (EMC)Interference resistance (EMC)Device safety (inverter)Preset standards for grid monitoring

05

Station design

Materials Exposition class for exterior partsExposition class for interior partsExterior wallsRoofFoundation trough

Exhaust air hoodAir grille/doors/framesAttachment pointsCable entriesEarthing bushing

Waterproof lightweight concrete LC 25/28 in accordance with DIN 1045:2001-07XC4, XF1, XA1 in accordance with DIN 1045:2001-07XC1 in accordance with DIN 1045:2001-07Exposed aggregate concrete, grain 8/16 (other options available)Concrete, laid on slidingOil-tight in accordance with Sec. 19 of German WHG(metal trough available as an option)Aluminium, not assembled for transportHot-galvanised steel (aluminium optional)4 piece Deha anchor, type 20 TNumber, position and design are project-specificHauff earthing bushing HEA-I-M12

Standards

Grid qualityCE conformity Type testConformity with EEG 2009 §6.1Conformity with Medium-Voltage Directive (BDEW)

of June 2008

DIN EN 61000-3-11:2001-04/DIN EN 61000-3-12:2005-09YesYes (Bureau Veritas)Yes (additional hardware may be required)Yes (additional hardware may be required)

Model CIS 1200

AC rated capacity (inverter) (PAC, r)Recommended DC output (kWp)Max. DC output (kWp)AC nominal current (A)

1,200 kVA1,3201,44034.64

System efficiency 4 CIS 1200

Max. efficiencyEuropean efficiency factorCalifornian efficiency factor

98.2 %97.8 %98.0 %

Auxiliary power supply 2

Standby/night-time power consumption (Pnight)Power consumption (Pday)

220 W220 W to 4,400 W

330 W330 W to 6,500 W

440 W440 W to 8,700 W

Medium-voltage transformer

Rated powerVector groupImpedance voltage 6

No-load losses 6

600 kVADyn5, optional Dyn5yn56 %320 W

900 kVA 1,200 kVA

400 W

1,200 kVA

580 W

Dimensions/weight

Dimensions in mm (W × H × D) 5 Weight in tonnes (t)

2,980 × 2,980 × 5,38028

2,980 × 2,980 × 6,98035

1. Depending on the operating state, de-rating by thetransformer monitoring system can result.

2. Values with external auxiliary power supply, vary dependingon expansion level and degree of soiling of filters.

3. The fans in the station are temperature regulated.

4. Values when an external auxiliary power supply is used.

5. Height specifications without exhaust air hoods. These mustbe mounted at the installation location; dimensions withoutspecial equipment.

6. Typical values.

CONERGY CIS 1200

Flextech Energy UG, Hubertusring 10, 49134 Wallenhorst, DeutschlandTel. 05407 - 319 3597

Flextech Energy Ltd., 216 NECKINGER ESTATE, SE16 3QA, London, GBTel. +44 20 3286 1947

E-Mail: [email protected]

CONTACT INFORMATION

OUR WORLD IS FULLOF ENERGY