connols-air vav air terminal units€¦ · connols-air constant air volume cooling only air...

4
Control Shroud BACnet TM Compliant DDC Controller Double-skin Casing AMCA Certified V750 X-Sensor CE Marking Double Insulated Transformer TABLE OF SUBMITTAL SHEETS: Page No Drawing No Description 2 VAXEP007-R1 CONNOLS-AIR PRESSURE INDEPENDENT COOLING ONLY VAV AIR TERMINAL UNIT (V750-I) 3 VAXEP008-R1 CONNOLS-AIR CONSTANT AIR VOLUME COOLING ONLY AIR TERMINAL UNIT (V750-C) 4 VAXEP009-R1 CONNOLS-AIR PRESSURE DEPENDENT COOLING ONLY VAV AIR TERMINAL UNIT (V750-D) CONNOLS-AIR VAV AIR TERMINAL UNITS Connols-Air DDC microprocessor based V750 air terminal units are the latest, state-of-the-art, high quality terminal units, which provide good control accuracy and capabilities required in every modern intelligent building of today. The air terminal units are capable of stand-alone operation. However, they may be connected with net-working devices and be integrated with the building automation system. The air terminal unit consists of an air valve with integrated pressure differential flow sensor, a digital thermostat and BACnet™ compliant DDC controller and is available in the following sizes 5, 6, 7, 8, 10, 12, 14, 16, and 18 covering air flow range up to 7,200 cmh (2,000 l/s). We have attached the following tabulated submittal sheets, which will provide you necessary information about our Connols-Air VAV air terminal units for your selection and design purposes. Cert. No.: SG00/00080 Scope: Design and Manufacturing OLS MANUFACTURING CO. email: [email protected] http://www.connols-air.com 3-B, Joo Koon Circle, Singapore 629034 Tel.: 68615253 Fax.: 68619850

Upload: others

Post on 18-Oct-2020

5 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: CONNOLS-AIR VAV AIR TERMINAL UNITS€¦ · CONNOLS-AIR CONSTANT AIR VOLUME COOLING ONLY AIR TERMINAL UNIT (V750-C) 4VAXEP009-R1 CONNOLS-AIR PRESSURE DEPENDENT COOLING ONLY VAV AIR

Control Shroud

BACnetTM Compliant DDC Controller

Double-skin Casing

AMCA CertifiedV750 X-Sensor

CE Marking Double Insulated Transformer

TABLE OF SUBMITTAL SHEETS:Page No Drawing No Description

2 VAXEP007-R1CONNOLS-AIR PRESSURE INDEPENDENT COOLING ONLY VAV AIR TERMINAL UNIT(V750-I)

3 VAXEP008-R1CONNOLS-AIR CONSTANT AIR VOLUME COOLING ONLY AIR TERMINAL UNIT(V750-C)

4 VAXEP009-R1CONNOLS-AIR PRESSURE DEPENDENT COOLING ONLY VAV AIR TERMINAL UNIT(V750-D)

CONNOLS-AIR VAV AIR TERMINAL UNITS

Connols-Air DDC microprocessor based V750 air terminal units are the latest, state-of-the-art, highquality terminal units, which provide good control accuracy and capabilities required in every modernintelligent building of today. The air terminal units are capable of stand-alone operation. However, theymay be connected with net-working devices and be integrated with the building automation system. Theair terminal unit consists of an air valve with integrated pressure differential flow sensor, a digitalthermostat and BACnet™ compliant DDC controller and is available in the following sizes 5, 6, 7, 8, 10,12, 14, 16, and 18 covering air flow range up to 7,200 cmh (2,000 l/s).

We have attached the following tabulated submittal sheets, which will provide you necessary informationabout our Connols-Air VAV air terminal units for your selection and design purposes.

Cert. No.:SG00/00080

Scope: Design and Manufacturing

OLS MANUFACTURING CO.

email: [email protected] http://www.connols-air.com

3-B, Joo Koon Circle, Singapore 629034Tel.: 68615253 Fax.: 68619850

Page 2: CONNOLS-AIR VAV AIR TERMINAL UNITS€¦ · CONNOLS-AIR CONSTANT AIR VOLUME COOLING ONLY AIR TERMINAL UNIT (V750-C) 4VAXEP009-R1 CONNOLS-AIR PRESSURE DEPENDENT COOLING ONLY VAV AIR

Y

Ød

(ID

DAirflow

76 L 40

A

End view A-A

Elevation view(Blade in full open position)

Section B-B(X-Sensor not shown

for clarity)

A B

B

DDC controller

X-Sensor

DDC controller 10

3

4

5

6

81

99

2

7

1

2

11

9

CE Marking Transformer

X-Sensor

PU tubingEqual tee fitting

3D view

In the interest of product improvement, we reserved the right to make changes without notice. All dimensions are in mm

Submittal

Title : CONNOLS-AIR PRESSURE INDEPENDENT COOLING ONLY VAV AIRTERMINAL UNIT (V750-I)

Project :

Dwn. By : San Date : 12/10/2020 Scale :

Chk. By : JohnDwg. No. : VAXEP007-R1

N.T.S

App. By : Wong

OLS MANUFACTURING CO.3-B, Joo Koon Circle, Singapore 629034

Tel.: 68615253 Fax.: 68619850email: [email protected] http://www.connols-air.com

NOTE:1. Connecting duct internal diameter should be 3mm bigger than Ød.

Refer to installation instruction VAXEP010.2. Equal tee fitting provided for easy flow verification.3. Refer to datasheet for details of controller and temperature controller.4. The performance of V750 X-Sensor is AMCA certified to accuracy

of ±3.7% or better in the velocity range of 4m/s to 13m/s.

TABLE 1: DIMENSIONS

Options Size Ød ØD Y L Qty

☐ 5 125 175 125 370

☐ 6 150 200 125 370

☐ 7 175 225 125 370

☐ 8 200 250 125 370

☐ 10 250 300 175 470

☐ 12 300 350 175 470

☐ 14 350 400 225 540

☐ 16 400 450 225 540

☐ 18 450 500 250 600

CONTROLLER OPTIONS:☐ Non☐ Standalone☐ Networked to BAS/ BMS via

BACnetTM protocol

TRANSFORMER OPTIONS:☐ Non☐ CE Marking double insulated

(230 to 24VAC)

TEMPERATURE CONTROLLEROPTIONS:☐ Non☐ LCD Room Unit☐ Blank Room Unit

No PARTS DESCRIPTIONS1 Inner Casing 0.7mm thk. Refer to material options.

2 Outer Casing 0.7mm thk. Refer to material options.

3 Damper Blade (Double skin) 0.7/1.0mm thk. Refer to material options.

4 Blade Shaft Ø12mm Aluminum5 Blade Seal 1.5mm thk. Solid Silicone6 End Ring 0.7mm thk. Refer to material options.

7 Insulation 25mm thk. 32kg/m3 Fiberglass

8 Bush Nylon

9 Controller Shroud 0.7mm thk. Refer to material options.

10 U-bolt Refer to material options.

11 Blade Mounting Bracket Refer to material options.

MATERIAL OPTIONS:☐ Hot-dip pregalvanized steel☐ Stainless steel SS304☐ Stainless steel SS316

OLS Manufacturing Co Pte Ltd. certifies that the V750 X-Sensor withintegral damper shown herein is licensed to bear the AMCA seal. Theratings shown are based on tests and procedures performed inaccordance with AMCA Publication 611 and comply with therequirements of the AMCA Certified Ratings Program.

Cert. No: SG00/00080

Page 3: CONNOLS-AIR VAV AIR TERMINAL UNITS€¦ · CONNOLS-AIR CONSTANT AIR VOLUME COOLING ONLY AIR TERMINAL UNIT (V750-C) 4VAXEP009-R1 CONNOLS-AIR PRESSURE DEPENDENT COOLING ONLY VAV AIR

Y

Ød

(ID

DAirflow

76 L 40

A

End view A-A

Elevation view(Blade in full open position)

Section B-B(X-Sensor not shown

for clarity)

A B

B

X-Sensor

10

3

4

5

6

81

99

2

7

1

2

11

9

X-Sensor

DDC controller

DDC controller

CE Marking TransformerPU tubingEqual tee fitting

3D view

In the interest of product improvement, we reserved the right to make changes without notice. All dimensions are in mm

Submittal

Title : CONNOLS-AIR CONSTANT AIR VOLUME COOLING ONLY AIRTERMINAL UNIT (V750-C)

Project :

Dwn. By : San Date : 12/10/2020 Scale :

Chk. By : JohnDwg. No. : VAXEP008-R1

N.T.S

App. By : Wong

3-B, Joo Koon Circle, Singapore 629034Tel.: 68615253 Fax.: 68619850

OLS MANUFACTURING CO.

email: [email protected] http://www.connols-air.com

TABLE 1: DIMENSIONS

Options Size Ød ØD Y L Qty

☐ 5 125 175 125 370

☐ 6 150 200 125 370

☐ 7 175 225 125 370

☐ 8 200 250 125 370

☐ 10 250 300 175 470

☐ 12 300 350 175 470

☐ 14 350 400 225 540

☐ 16 400 450 225 540

☐ 18 450 500 250 600

No PARTS DESCRIPTIONS1 Inner Casing 0.7mm thk. Refer to material options.

2 Outer Casing 0.7mm thk. Refer to material options.

3 Damper Blade (Double skin) 0.7/1.0mm thk. Refer to material options.

4 Blade Shaft Ø12mm Aluminum5 Blade Seal 1.5mm thk. Solid Silicone6 End Ring 0.7mm thk. Refer to material options.

7 Insulation 25mm thk. 32kg/m3 Fiberglass

8 Bush Nylon

9 Controller Shroud 0.7mm thk. Refer to material options.

10 U-bolt Refer to material options.

11 Blade Mounting Bracket Refer to material options.

NOTE:1. Connecting duct internal diameter should be 3mm bigger than Ød.

Refer to installation instruction VAXEP010.2. Equal tee fitting provided for easy flow verification.3. Refer to datasheet for details of controller and temperature controller.4. The performance of V750 X-Sensor is AMCA certified to accuracy

of ±3.7% or better in the velocity range of 4m/s to 13m/s.

OLS Manufacturing Co Pte Ltd. certifies that the V750 X-Sensor withintegral damper shown herein is licensed to bear the AMCA seal. Theratings shown are based on tests and procedures performed inaccordance with AMCA Publication 611 and comply with therequirements of the AMCA Certified Ratings Program.

\\OLSSVR-2\W03. R_D Engineering\Personal Folders\John Gong\PD070 Study on System Characteristic of VAV\VAV Product Drawing Library\iso logo.png

\\OLSSVR-2\W03. R_D Engineering\Personal Folders\John Gong\PD070 Study on System Characteristic of VAV\VAV Product Drawing Library\SAC LOGO.JPG

CONTROLLER OPTIONS:☐ Non☐ Standalone☐ Networked to BAS/ BMS via

BACnetTM protocol

TRANSFORMER OPTIONS:☐ Non☐ CE Marking double insulated

(230 to 24VAC)

MATERIAL OPTIONS:☐ Hot-dip pregalvanized steel☐ Stainless steel SS304☐ Stainless steel SS316

Cert. No: SG00/00080

Page 4: CONNOLS-AIR VAV AIR TERMINAL UNITS€¦ · CONNOLS-AIR CONSTANT AIR VOLUME COOLING ONLY AIR TERMINAL UNIT (V750-C) 4VAXEP009-R1 CONNOLS-AIR PRESSURE DEPENDENT COOLING ONLY VAV AIR

Y

Ød

(ID

DAirflow

76 L 40

A

End view A-A

Elevation view(Blade in full open position)

Section B-B A B

B

DDC controller

DDC controller 10

3

4

5

6

81

99

2

7

1

2

11

9

CE Marking Transformer

3D view

In the interest of product improvement, we reserved the right to make changes without notice. All dimensions are in mm

Submittal

Title : CONNOLS-AIR PRESSURE DEPENDENT COOLING ONLY VAV AIRTERMINAL UNIT (V750-D)

Project :

Dwn. By : San Date : 12/10/2020 Scale :

Chk. By : JohnDwg. No. : VAXEP009-R1

N.T.S

App. By : Wong

3-B, Joo Koon Circle, Singapore 629034Tel.: 68615253 Fax.: 68619850

OLS MANUFACTURING CO.

email: [email protected] http://www.connols-air.com

TABLE 1: DIMENSIONS

Options Size Ød ØD Y L Qty

☐ 5 125 175 125 370

☐ 6 150 200 125 370

☐ 7 175 225 125 370

☐ 8 200 250 125 370

☐ 10 250 300 175 470

☐ 12 300 350 175 470

☐ 14 350 400 225 540

☐ 16 400 450 225 540

☐ 18 450 500 250 600

No PARTS DESCRIPTIONS1 Inner Casing 0.7mm thk. Refer to material options.

2 Outer Casing 0.7mm thk. Refer to material options.

3 Damper Blade (Double skin) 0.7/1.0mm thk. Refer to material options.

4 Blade Shaft Ø12mm Aluminum5 Blade Seal 1.5mm thk. Solid Silicone6 End Ring 0.7mm thk. Refer to material options.

7 Insulation 25mm thk. 32kg/m3 Fiberglass

8 Bush Nylon

9 Controller Shroud 0.7mm thk. Refer to material options.

10 U-bolt Refer to material options.

11 Blade Mounting Bracket Refer to material options.

NOTE:1. Connecting duct internal diameter should be 3mm bigger than

Ød. Refer to installation instruction VAXEP010.2. Refer to datasheet for details of controller and temperature

controller.

CONTROLLER OPTIONS:☐ Non☐ Standalone☐ Networked to BAS/ BMS via

BACnetTM protocol

TRANSFORMER OPTIONS:☐ Non☐ CE Marking double insulated

(230 to 24VAC)

TEMPERATURE CONTROLLEROPTIONS:☐ Non☐ LCD Room Unit☐ Blank Room Unit

MATERIAL OPTIONS:☐ Hot-dip pregalvanized steel☐ Stainless steel SS304☐ Stainless steel SS316

Cert. No: SG00/00080