current study status of high gradient at kek fumio furuta kek

9
Current study status of high gradient at KEK Fumio Furuta KEK SCRF meeting Fermilab. Apr. 21-25 2008

Upload: jonas-harvey

Post on 01-Jan-2016

21 views

Category:

Documents


1 download

DESCRIPTION

Current study status of high gradient at KEK Fumio Furuta KEK SCRF meeting Fermilab. Apr. 21-25 2008. Single cell cavity status (ICHIRO center cell shape). Ave. Eacc=46.7 ± 1.9 MV/m. ACD: Qo=0.8e10@40MV/m. ACD target. Recipe : CBP(100um)+CP(10um)+EP(80um) - PowerPoint PPT Presentation

TRANSCRIPT

Page 1: Current study status of high gradient at KEK Fumio Furuta KEK

Current study status of high gradient at KEK

Fumio Furuta

KEK

SCRF meeting Fermilab. Apr. 21-25 2008

Page 2: Current study status of high gradient at KEK Fumio Furuta KEK

108

109

1010

1011

0 10 20 30 40 50 60

IS#2IS#3IS#4IS#5IS#7CLG#1

Qo

Eacc[MV/m]

0 10 20 30 40 50 60

Num

ber

Eacc [MV/m]

1

2

3

4

5

N=6

ACD targetACD: Qo=0.8e10@40MV/m

Ave. Eacc=46.7±1.9MV/m

Single cell cavity status (ICHIRO center cell shape)

Recipe : CBP(100um)+CP(10um)+EP(80um) +EP(20m)+flash EP(3m) +HPR+Baking

Narrow scattering, high performance.

MP process needed. How to eliminate MP?

Strengthen rinsing after EP.

Page 3: Current study status of high gradient at KEK Fumio Furuta KEK

ICHIRO 9-cell cavity status

108

109

1010

1011

0 10 20 30 40 50

Qo

Eacc [MV/m]

9cell #0 w/o HOMEacc=29.3Qo=1.02e10

quench

9cell #1 w/ HOMEacc=19.08MV/mQo=3.64e9

FE9cell-#1~#3

9cell-#0 (w/o HOM)

MP barrier at taper of BP

FE caused by end group

Large beam tube, complicated structure of end group

Contamination from HPR pump by long operation.

Key points

Re-design of ICHIRO and end-single cell study

Replacement of HPR pump: plunger->diaphragm

Page 4: Current study status of high gradient at KEK Fumio Furuta KEK

108

109

1010

1011

0 10 20 30 40 50 60

Qo

Eacc [MV/m]

2007/3/7 Wed.

Eacc=6.92MV/mQo=6.76e9 @2K

limited by FE

X-ray >6MV/m.

HPR(UPW@Nomura, 3/6)TOC=5ppb, Bacteria=

Field Emission by Plunger HPR Pump contamination

Final filter -before use- Contaminated

Silicon greaseused at plunger sealing of HPR pump!

HPR pump was replaced to diaphragm type on beginning of Sep. 2007

Successfully Qualified by single cell cavity tests!

Fixed!

Page 5: Current study status of high gradient at KEK Fumio Furuta KEK

108

109

1010

1011

0 10 20 30 40 50 60

Qo

Eacc [MV/m]108

109

1010

1011

0 10 20 30 40 50 60

Qo

Eacc [MV/m]

108

109

1010

1011

0 10 20 30 40 50 60

Qo

Eacc [MV/m]

108

109

1010

1011

0 10 20 30 40 50 60

Qo

Eacc [MV/m]

42MV/m

45MV/m

ISE#2 (old)

ISE#3 (new)

ISE#4 (new)

ISE#5 (old end group)

Full HOM

Just HOM cylinder

50MV/m

52MV/m

Ethanol Rinsing

Ethanol Rinsing

End-single cell cavities

End-cell shape has no problem.

Ethanol rinse has big effects on end groups.

Page 6: Current study status of high gradient at KEK Fumio Furuta KEK

ISE#5 tight loop test

EP(20m)+flash EP(3m) +Ethanol rinsing (10min., r.t.) +Degreasing(MICRO-90, 2%, 1hr, 50C) +HPR(Nomura, UPW) +Baking(120C*48hrs)

Eacc[MV/m] Qo

3rd 40.2 9.43e9

4th 39.9 8.83e9

5th 31.1 4.98e9

12th 45.1 8.63e9

Repeat

ISE#5

Full HOM

108

109

1010

1011

0 10 20 30 40 50

3rd4th5th12th

Qo

Eacc [MV/m]

Page 7: Current study status of high gradient at KEK Fumio Furuta KEK

9-cell = + x7 + = 50MV/m?

Center-cellend-cell end-cell

Old

New

Redesigned 9-cell cavity : New Ichiro 9-cell

Ready to EP, VT

I9#5→sent to J-lab (EP+VT)*3.

108

109

1010

1011

0 10 20 30 40 50

ICHIRO5_17feb08_test4(CW)

CW meas.pulse meas.

Qo

Eacc [MV/m]

Eacc=36.5MV/mQo=5.94e9 @2K

limited by FE

X-ray>20MV/m,(>1mRad/hr)

#5, #6 :w/o end groups

#7, #8 :w/ end groups

Page 8: Current study status of high gradient at KEK Fumio Furuta KEK

+EP(20m) + Degreasing + HPR

+EP(20m) + flash EP(3m) + Degreasing + Ethanol rinsing + HPR

+EP(20m) + Ethanol rinsing + HPR

will be tested

Studies for strengthen rinsing by single cell cavities

+EP(20m) + flash EP(3m) + HPR

High reliability, but still MP process needed.

Well work for reduction of MP.

Well work for end group rinsing.

Need more statistics.

(A)

(B)

(C)

(D)

46.7±1.9MV/m (N=6)

44.2±6.4MV/m (N=5)

Page 9: Current study status of high gradient at KEK Fumio Furuta KEK

Summary

・ Surface treatment recipe for single cell (center cell shape) was almost fixed. Degreasing has effect on reduction of MP.

・ Limitations of ICHIRO 9-cell (#0,1,2 and 3) cavities were related to end group and contamination from plunger HPR pump.

・ Plunger pump was replaced to diaphragm pump, it works well.

・ End-cell shape single cell cavities were fabricated and tested to understand the end groups.

・ Ethanol rinsing have effect on end group rinsing. End cell cavity with full end group reached 45MV/m. For the end single cell cavities, more statistics will be collected.

・ 4 re-designed ICHIRO 9-cell (#5, 6, 7, and 8) were fabricated.

#5 and #6 have simple beam tube, #5 was tested and reached 36MV/m at J-lab.

#7 and #8 have full end group, will be tested next month at KEK.