data sheet 3wl1116-2bb34-4an2-z c22...short-circuit current making capacity (icm) at 415 v / rated...

6
Data sheet 3WL1116-2BB34-4AN2-Z C22 FIXED-MOUNTED CIRCUIT BREAKER 3-POLE, SIZE I, IEC IN=1600A TO 690V, AC50/60HZ ICU=55KA AT 500V FRNT.CONN. TOP/BOT. DUAL-HOLE Model product brand name SENTRON Product designation ACB Design of the operating mechanism Pushbutton Type of the driving mechanism Manual/motorized operating mechanism with mechanical and electrical closing Type of the driving mechanism / motor drive Yes Design of the overcurrent release ETU15B General technical data Number of poles 3 Size of the circuit-breaker 1 Electrical endurance (switching cycles) / typical 20 000 Usage category B circuit-breaker / Design 3WL1116 Mechanical service life (switching cycles) / typical 20 000 Voltage Rated insulation voltage Ui V 1 000 Insulation voltage / Rated value V 1 000 3WL1116-2BB34-4AN2-Z C22 Changes preserved Page 1/ 6 09.12.2015 © Copyright Siemens AG

Upload: others

Post on 24-Mar-2020

7 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Data sheet 3WL1116-2BB34-4AN2-Z C22...Short-circuit current making capacity (Icm) at 415 V / Rated value kA 121 at 500 V / Rated value kA 121 at 690 V / Rated value kA 88 Connections

Data sheet 3WL1116-2BB34-4AN2-Z C22FIXED-MOUNTED CIRCUIT BREAKER 3-POLE, SIZEI, IEC IN=1600A TO 690V, AC50/60HZ ICU=55KA AT500V FRNT.CONN. TOP/BOT. DUAL-HOLE

Modelproduct brand name SENTRONProduct designation ACBDesign of the operating mechanism PushbuttonType of the driving mechanism Manual/motorized operating mechanism with

mechanical and electrical closingType of the driving mechanism / motor drive YesDesign of the overcurrent release ETU15B

General technical dataNumber of poles 3Size of the circuit-breaker 1Electrical endurance (switching cycles) / typical 20 000Usage category Bcircuit-breaker / Design 3WL1116Mechanical service life (switching cycles) / typical 20 000

VoltageRated insulation voltage Ui V 1 000Insulation voltage / Rated value V 1 000

3WL1116-2BB34-4AN2-Z C22 Changes preservedPage 1/6 09.12.2015 © Copyright Siemens AG

Page 2: Data sheet 3WL1116-2BB34-4AN2-Z C22...Short-circuit current making capacity (Icm) at 415 V / Rated value kA 121 at 500 V / Rated value kA 121 at 690 V / Rated value kA 88 Connections

Protection classProtection class IP IP20Protective function of the overcurrent release LI

DissipationPower loss [W]

● for rated value of the current / at AC / in hotoperating state / per pole

W 50

● maximum W 150

ElectricityContinuous current / Rated value A 1 600Adjustable response value current

● of the current-dependent overload release /Full-scale value

A 1 600

● of the instantaneous short-circuit release / initialvalue

A 3 200

● of the instantaneous short-circuit release / Full-scale value

A 12 800

Short-time current resistance (Icw)

● limited to 0.5 s / Rated value kA 55

● limited to 1 s / Rated value kA 42

● limited to 2 s / Rated value kA 29.5

● limited to 3 s / Rated value kA 24

Main circuitOperating frequency

● 1 / Rated value Hz 50

● 2 / Rated value Hz 60

Operating voltage

● at AC / at 50/60 Hz / Rated value V 690

Operating current

● at 40 °C / Rated value A 1 600

● at 50 °C / Rated value A 1 600

● at 55 °C / Rated value A 1 600

● at 60 °C / Rated value A 1 600

● at 65 °C / Rated value A 1 600

● at 70 °C / Rated value A 1 490

Auxiliary circuitNumber of NC contacts / for auxiliary contacts 2Number of NO contacts / for auxiliary contacts 2

SuitabilitySuitability for use system protection

3WL1116-2BB34-4AN2-Z C22 Changes preservedPage 2/6 09.12.2015 © Copyright Siemens AG

Page 3: Data sheet 3WL1116-2BB34-4AN2-Z C22...Short-circuit current making capacity (Icm) at 415 V / Rated value kA 121 at 500 V / Rated value kA 121 at 690 V / Rated value kA 88 Connections

Adjustable parametersAdjustable response value current / of the current-dependent overload release / initial value

A 800

Product detailsProduct component

● Trip indicator Yes

● Voltage trigger No

● undervoltage release Yes

Product expansion / optional / motor drive No

Product functionProduct function

● Ground fault protection No

● Phase failure detection No

Display and operationDisplay version without display

Short circuitOperational short-circuit current breaking capacity(Ics)

● at 415 V / Rated value kA 55

● at 500 V / Rated value kA 55

● at 690 V / Rated value kA 42

Maximum short-circuit current breaking capacity (Icu)

● at 415 V / Rated value kA 55

● at 500 V / Rated value kA 55

● at 690 V / Rated value kA 42

Short-circuit current making capacity (Icm)

● at 415 V / Rated value kA 121

● at 500 V / Rated value kA 121

● at 690 V / Rated value kA 88

ConnectionsArrangement of electrical connectors / for maincurrent circuit

Main connection top front/bottom double hole

Type of electrical connection / for main current circuit busbar connection

Mechanical DesignHeight mm 541Width mm 320Depth mm 374Mounting type fixed mounting

Environmental conditionsAmbient temperature

3WL1116-2BB34-4AN2-Z C22 Changes preservedPage 3/6 09.12.2015 © Copyright Siemens AG

Page 4: Data sheet 3WL1116-2BB34-4AN2-Z C22...Short-circuit current making capacity (Icm) at 415 V / Rated value kA 121 at 500 V / Rated value kA 121 at 690 V / Rated value kA 88 Connections

● during operation / minimum °C -20

● during operation / maximum °C 70

● during storage / minimum °C -40

● during storage / maximum °C 70

CertificatesEquipment marking

● acc. to DIN EN 61346-2 Q

● acc. to DIN EN 81346-2 Q

General Product Approval Declaration ofConformity

Test Certificates

speziellePrüfbescheinigunge

n

sonstig

Shipping Approval

ShippingApproval

other

Umweltbestätigung sonstig

Further informationIndustry Mall (Online ordering system)https://eb.automation.siemens.com/mall/en/WW/Catalog/Product/3WL11162BB344AN2-Z C22

Service&Support (Manuals, Certificates, Characteristics, FAQs,...)http://support.automation.siemens.com/WW/view/en/3WL11162BB344AN2-Z C22/all

Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, ...)http://www.automation.siemens.com/bilddb/cax_en.aspx?mlfb=3WL11162BB344AN2-Z C22

CAx-Online-Generatorhttp://www.siemens.com/cax

Tender specificationshttp://ausschreibungstexte.siemens.com/tiplv

3WL1116-2BB34-4AN2-Z C22 Changes preservedPage 4/6 09.12.2015 © Copyright Siemens AG

Page 5: Data sheet 3WL1116-2BB34-4AN2-Z C22...Short-circuit current making capacity (Icm) at 415 V / Rated value kA 121 at 500 V / Rated value kA 121 at 690 V / Rated value kA 88 Connections

123.

527

5

10

15270

300

439.

5

7632

7.5

401.

5

45

106

127

20

130

150

5.5

8215

47

6

39

551

60 90 90

55

421

14

4040 80

8058139

320

9

3WL1116-2BB34-4AN2-Z C22 Changes preservedPage 5/6 09.12.2015 © Copyright Siemens AG

Page 6: Data sheet 3WL1116-2BB34-4AN2-Z C22...Short-circuit current making capacity (Icm) at 415 V / Rated value kA 121 at 500 V / Rated value kA 121 at 690 V / Rated value kA 88 Connections

last modified: 19.11.2015

3WL1116-2BB34-4AN2-Z C22 Changes preservedPage 6/6 09.12.2015 © Copyright Siemens AG