designing cold-formed steel curtain wall · pdf file1 designing cold-formed steel curtain wall...

38
1 Designing Cold-Formed Steel Curtain Wall Connections Kirsten Zeydel, S.E. Ficcadenti & Waggoner, Consulting Structural Engineers Annie Kao, P.E. Simpson Strong-Tie Company, Inc. April 11, 2012 Overview Code Requirements for Components & Cladding Loading on Connections for Typical Wall Configurations Engineered Connection Design Proprietary Connection Products 2 Design of CFS Curtain Wall Connections (K. Zeydel/A. Kao, 4/11/12)

Upload: trinhtruc

Post on 07-Feb-2018

223 views

Category:

Documents


4 download

TRANSCRIPT

Page 1: Designing Cold-Formed Steel Curtain Wall · PDF file1 Designing Cold-Formed Steel Curtain Wall Connections Kirsten Zeydel, S.E. Ficcadenti & Waggoner, Consulting Structural Engineers

1

Designing Cold-Formed Steel Curtain Wall Connections

Kirsten Zeydel, S.E.Ficcadenti & Waggoner, Consulting Structural Engineers

Annie Kao, P.E.Simpson Strong-Tie Company, Inc.

April 11, 2012

Overview

• Code Requirements for Components & Cladding

• Loading on Connections for Typical Wall Configurations

• Engineered Connection Design

• Proprietary Connection Products

2

Design of CFS Curtain Wall Connections (K. Zeydel/A. Kao, 4/11/12)

Page 2: Designing Cold-Formed Steel Curtain Wall · PDF file1 Designing Cold-Formed Steel Curtain Wall Connections Kirsten Zeydel, S.E. Ficcadenti & Waggoner, Consulting Structural Engineers

2

Code Requirements for Components & Cladding

• Structural Design

• Wind Loads

• Seismic Loads

• Deflection Limitations

• Accommodate Building Movement

• Vertical Movements

• Lateral Drifts

3

Design of CFS Curtain Wall Connections (K. Zeydel/A. Kao, 4/11/12)

Wind Design Loads

• Loads decrease with increased Tributary Area

• Suction Loads typically govern and are typically constant over height of building

GCp = 1.4 (Elements in areas of discontinuity)

GCp = 1.1 (Elements not in areas of discontinuity)

P = qh(GCp-GCpi)

• 2010 California Building Code (2009 IBC) (ASCE-7 05 6.5.12.4) Wind Loads

Components and Cladding

4

Design of CFS Curtain Wall Connections (K. Zeydel/A. Kao, 4/11/12)

Page 3: Designing Cold-Formed Steel Curtain Wall · PDF file1 Designing Cold-Formed Steel Curtain Wall Connections Kirsten Zeydel, S.E. Ficcadenti & Waggoner, Consulting Structural Engineers

3

Seismic Design Loads

• Loads Increase with Building Height

• Fp min = 0.3SDSIpWp

• Fp max = 1.6SDSIpWp

• 2010 California Building Code (2009 IBC) Seismic Loads – ASCE 7 -13.3 - Nonstructural Components

Fp =0.4apSDSIp

Rp( )1 + 2

hz

ap = 1.0 and Rp =2.5 (Table 13.5-1)For Fasteners of the Connecting system ap = 1.25 and Rp = 1.0 (Exterior Only)

5

Wp

Design of CFS Curtain Wall Connections (K. Zeydel/A. Kao, 4/11/12)

Deflection Limitations

• Out-of-plane deflection limitations are based upon limiting distress to finishes based on curvature of wall system.

– Metal Panels: L/180 to L/240*– EIFS: L/240 to L/360– Cement Plaster: L/360*– Brick Veneer: L/360 to L/600 or more– Stone Veneer: L/360 to L/600 or more

• Out-of-plane deflections for cold formed wall systems are typically governed by wind loading.

• CBC Table 1604.3 – Serviceability limits for wall deflections based upon 70% of Component and Cladding Wind Loads

6

Design of CFS Curtain Wall Connections (K. Zeydel/A. Kao, 4/11/12)

Page 4: Designing Cold-Formed Steel Curtain Wall · PDF file1 Designing Cold-Formed Steel Curtain Wall Connections Kirsten Zeydel, S.E. Ficcadenti & Waggoner, Consulting Structural Engineers

4

Accommodation of Building Movements

• Accommodation of Building Movements

– Vertical Deflection of Perimeter Beams/Slabs

– Lateral Drift of Building Frame System

7

Design of CFS Curtain Wall Connections (K. Zeydel/A. Kao, 4/11/12)

Accommodation of Building Movements

Allowable Vertical Deflection of Perimeter Beams/Slabs

• With typical 30 foot spans and design live load deflections of L/360, building live load deflections can reach 1 inch

• Value for perimeter beam live load deflection is typically limited to ¾ inch or less

• Actual design value must be verified with Engineer of Record for structure

8

Design of CFS Curtain Wall Connections (K. Zeydel/A. Kao, 4/11/12)

Page 5: Designing Cold-Formed Steel Curtain Wall · PDF file1 Designing Cold-Formed Steel Curtain Wall Connections Kirsten Zeydel, S.E. Ficcadenti & Waggoner, Consulting Structural Engineers

5

Accommodation of Building Movements

Allowable Lateral Drift of Typical Systems

• Actual drift should be obtained from Engineer of Record for structure

• For Category II structure ∆a can be 2.5% of story height. (e.g. 15 ft floor @ 2.5% drift ∆a = 4 ½”)

9

Design of CFS Curtain Wall Connections (K. Zeydel/A. Kao, 4/11/12)

Building Systems vs. Finish System

• Steel Moment Frames• Concrete Moment Frames• Eccentric Braced Frames• Concentric Braced Frames• Concrete Shear Walls

• EIFS Systems• Cement Plaster Systems• Adhered Veneer Systems• Anchored Veneer and

Stone Systems

RIGIDSYSTEMS

FLEXIBLESYSTEMSBUILDING SYSTEMS FINISH SYSTEMS

10

Design of CFS Curtain Wall Connections (K. Zeydel/A. Kao, 4/11/12)

Page 6: Designing Cold-Formed Steel Curtain Wall · PDF file1 Designing Cold-Formed Steel Curtain Wall Connections Kirsten Zeydel, S.E. Ficcadenti & Waggoner, Consulting Structural Engineers

6

Code Requirements for Drift Accommodation

• ASCE 7 – 13.5.2 & 13.5.3

• Architectural components need to be designed for Fp forces and for relative seismic displacement

• Connecting members of exterior wall elements shall have sufficient ductility and adequate fastener strength to preclude a brittle failure at or near the fasteners.

11

Design of CFS Curtain Wall Connections (K. Zeydel/A. Kao, 4/11/12)

Code Requirements for Drift Accommodation

12

• ASCE 7 – 13.5.2 & 13.5.3

Design of CFS Curtain Wall Connections (K. Zeydel/A. Kao, 4/11/12)

Page 7: Designing Cold-Formed Steel Curtain Wall · PDF file1 Designing Cold-Formed Steel Curtain Wall Connections Kirsten Zeydel, S.E. Ficcadenti & Waggoner, Consulting Structural Engineers

7

Code Requirements for Drift Accommodation

• ASCE 7 – 13.5.3

13

Design of CFS Curtain Wall Connections (K. Zeydel/A. Kao, 4/11/12)

DSA & OSHPD Specific Code Requirements

• 2010 California Building Code Title 24 Requirement for DSA and OSHPD

• Importance Factor

• DSA only permits 80% of allowable loads of code report listed products unless cyclically tested (IR A-5)

• Prohibits use of shotpins in concrete (PAF) in exterior wall framing

14

Design of CFS CurtainWall Connections(K. Zeydel/A. Kao, 4/11/12)

Page 8: Designing Cold-Formed Steel Curtain Wall · PDF file1 Designing Cold-Formed Steel Curtain Wall Connections Kirsten Zeydel, S.E. Ficcadenti & Waggoner, Consulting Structural Engineers

8

FEMA P-749 – Seismic Performance

• Limit the chance of total or partial collapse as a result of MCER ground motions to various percentages depending upon Occupancy Categories

• For all structures, minimize the risk that, in likely earthquakes, debris generated by damage to cladding, ceilings, or mechanical or electrical systems will fall on building occupants or pedestrians.

• To the extent practicable, avoid economic losses associated with damage to structural and nonstructural systems as a result of relatively frequent moderate earthquake events.

15

Design of CFS Curtain Wall Connections (K. Zeydel/A. Kao, 4/11/12)

Questions?

• Please type your question into the chat box.

Design of CFS Curtain Wall Connections (K. Zeydel/A. Kao, 4/11/12)

16

Page 9: Designing Cold-Formed Steel Curtain Wall · PDF file1 Designing Cold-Formed Steel Curtain Wall Connections Kirsten Zeydel, S.E. Ficcadenti & Waggoner, Consulting Structural Engineers

9

Typical Wall Configurations

• Balloon Framed Systems

• Spandrel Framed Systems

• Floor to Floor Framed Systems

17

Design of CFS Curtain Wall Connections (K. Zeydel/A. Kao, 4/11/12)

Vertical Deflection Comparison –Un-Deflected Shape

18

Design of CFS Curtain Wall Connections (K. Zeydel/A. Kao, 4/11/12)

Page 10: Designing Cold-Formed Steel Curtain Wall · PDF file1 Designing Cold-Formed Steel Curtain Wall Connections Kirsten Zeydel, S.E. Ficcadenti & Waggoner, Consulting Structural Engineers

10

Vertical Deflection Comparison –Deflected Shape

19

Design of CFS Curtain Wall Connections (K. Zeydel/A. Kao, 4/11/12)

Lateral Deflection Comparison –Un-Deflected Shape

20

Design of CFS Curtain Wall Connections (K. Zeydel/A. Kao, 4/11/12)

Page 11: Designing Cold-Formed Steel Curtain Wall · PDF file1 Designing Cold-Formed Steel Curtain Wall Connections Kirsten Zeydel, S.E. Ficcadenti & Waggoner, Consulting Structural Engineers

11

Lateral Deflection Comparison –Deflected Shape – Drift Joints Do Not Allow for Drift

21

Design of CFS Curtain Wall Connections (K. Zeydel/A. Kao, 4/11/12)

Lateral Deflection Comparison –Deflected Shape – Drift Joints Allow for Drift

22

Design of CFS Curtain Wall Connections (K. Zeydel/A. Kao, 4/11/12)

Page 12: Designing Cold-Formed Steel Curtain Wall · PDF file1 Designing Cold-Formed Steel Curtain Wall Connections Kirsten Zeydel, S.E. Ficcadenti & Waggoner, Consulting Structural Engineers

12

Balloon Framed Systems23

VerticalSlip Connection

Bearing Connection

VerticalSlip Connection

Design of CFS Curtain Wall Connections (K. Zeydel/A. Kao, 4/11/12)

Balloon Framed Systems: Loading24

Analysis ModelGravity Loading

RG = wG * H

H

wG

wW

RW1

RW2

RW3

Wind Loading

Design of CFS CurtainWall Connections

(K. Zeydel/A. Kao, 4/11/12)

Page 13: Designing Cold-Formed Steel Curtain Wall · PDF file1 Designing Cold-Formed Steel Curtain Wall Connections Kirsten Zeydel, S.E. Ficcadenti & Waggoner, Consulting Structural Engineers

13

Balloon Framed Systems: Seismic Loading

25

Analysis Model

H

ws

RS1

RS2

RS3

Seismic LoadingOut-of-Plane

ws

RS1

RS2

RS3

Seismic LoadingIn-Plane

Design of CFS CurtainWall Connections

(K. Zeydel/A. Kao, 4/11/12)

Vertical Slip Connections –Loading Conditions to Consider

Balloon Framed Systems: Clip Loading26

PSPW

PS

Design of CFS Curtain Wall Connections (K. Zeydel/A. Kao, 4/11/12)

Page 14: Designing Cold-Formed Steel Curtain Wall · PDF file1 Designing Cold-Formed Steel Curtain Wall Connections Kirsten Zeydel, S.E. Ficcadenti & Waggoner, Consulting Structural Engineers

14

Spandrel Framed Systems27

Vertical Rigid Conn. @ Ea. Floor

Bearing Connection

VerticalRigid Connection

Kicker Support

Drift Joint Btwn Ea. Floor - Allows for Vertical and In-Plane Differential Movement

Design of CFS Curtain Wall Connections (K. Zeydel/A. Kao, 4/11/12)

Spandrel Framed Systems: Loading28

Analysis Model

H

Gravity Loading

RG1

wG

RG2 = wG * H

RG3

wW

RW1

RW2d

Wind Loading

RW2k

RW3d

RW3k

Design of CFS CurtainWall Connections

(K. Zeydel/A. Kao, 4/11/12)

Page 15: Designing Cold-Formed Steel Curtain Wall · PDF file1 Designing Cold-Formed Steel Curtain Wall Connections Kirsten Zeydel, S.E. Ficcadenti & Waggoner, Consulting Structural Engineers

15

Spandrel Framed Systems: Loading29

Analysis Model

H

wS

RS1

RS2d

RS2k

RS3d

RS32k

Seismic LoadingOut-of-Plane

Seismic LoadingIn-Plane

ws

RS1

RS2

RS3

Design of CFS CurtainWall Connections

(K. Zeydel/A. Kao, 4/11/12)

Spandrel Framed Systems Loading30

Isolation Joint Allowing Vertical / Lateral Movement

Design of CFS Curtain Wall Connections (K. Zeydel/A. Kao, 4/11/12)

Page 16: Designing Cold-Formed Steel Curtain Wall · PDF file1 Designing Cold-Formed Steel Curtain Wall Connections Kirsten Zeydel, S.E. Ficcadenti & Waggoner, Consulting Structural Engineers

16

Rigid Connections –Loading Conditions to Consider

Spandrel Framed Systems: Clip Loading31

PSPW

PS

PGPGPG

Design of CFS Curtain Wall Connections (K. Zeydel/A. Kao, 4/11/12)

Spandrel Framed Systems

Kicker Connection

32

PW

orPS

PW

orPS

PW

orPS

Design of CFS Curtain Wall Connections (K. Zeydel/A. Kao, 4/11/12)

Page 17: Designing Cold-Formed Steel Curtain Wall · PDF file1 Designing Cold-Formed Steel Curtain Wall Connections Kirsten Zeydel, S.E. Ficcadenti & Waggoner, Consulting Structural Engineers

17

Floor to Floor Framed Systems33

Design of CFS Curtain Wall Connections (K. Zeydel/A. Kao, 4/11/12)

Floor to Floor Framed Systems34

Bearing Connection Each Floor

Expansion Joint for Vertical and Lateral Movement

Typical Connection

Design of CFS Curtain Wall Connections (K. Zeydel/A. Kao, 4/11/12)

Page 18: Designing Cold-Formed Steel Curtain Wall · PDF file1 Designing Cold-Formed Steel Curtain Wall Connections Kirsten Zeydel, S.E. Ficcadenti & Waggoner, Consulting Structural Engineers

18

Floor to Floor Framed Systems: Loading35

HwG

Gravity Loading

RG = wG * H

Wind Loading

wW

RW1= ww * H/2

RW2= ww * H/2

Analysis Model

Design of CFS Curtain Wall Connections (K. Zeydel/A. Kao, 4/11/12)

Floor to Floor Framed Systems: Loading36

H

wS

RS1= wS * H/2

RS2= wS * H/2

Analysis ModelSeismic LoadingOut-of-Plane

Seismic LoadingIn-Plane

ws

RS1

RS2

Design of CFS Curtain Wall Connections (K. Zeydel/A. Kao, 4/11/12)

Page 19: Designing Cold-Formed Steel Curtain Wall · PDF file1 Designing Cold-Formed Steel Curtain Wall Connections Kirsten Zeydel, S.E. Ficcadenti & Waggoner, Consulting Structural Engineers

19

Floor to Floor Framed Systems: Connection Detail

PS

PGPGPG

PW

PW

PS

PSPS

37

Design of CFS Curtain Wall Connections (K. Zeydel/A. Kao, 4/11/12)

Framing with Drift Clips38

Design of CFS Curtain Wall Connections (K. Zeydel/A. Kao, 4/11/12)

Page 20: Designing Cold-Formed Steel Curtain Wall · PDF file1 Designing Cold-Formed Steel Curtain Wall Connections Kirsten Zeydel, S.E. Ficcadenti & Waggoner, Consulting Structural Engineers

20

Framing with Drift Clips

Gap Forms at One Building Corner

Wall Collides with Perpendicular Wall at Other Building Corner

39

Design of CFS Curtain Wall Connections (K. Zeydel/A. Kao, 4/11/12)

Framing with Drift Clips

Seismic shear in wall piers may not exceed capacity of the sheathing.

Each exterior wall must be designed to transfer the induced seismic load from its self weight down to the slab on grade.

40

Design of CFS Curtain Wall Connections (K. Zeydel/A. Kao, 4/11/12)

Page 21: Designing Cold-Formed Steel Curtain Wall · PDF file1 Designing Cold-Formed Steel Curtain Wall Connections Kirsten Zeydel, S.E. Ficcadenti & Waggoner, Consulting Structural Engineers

21

Framing with Drift ClipsLoading on Connection

Only design for resultant wind loading.

PW

If building drift under MCE exceeds slot size then connection and anchorage must be checked for induced loading.

41

Design of CFS Curtain Wall Connections (K. Zeydel/A. Kao, 4/11/12)

Engineered Connection Design

• Loads to consider– Gravity

– Wind

– Seismic• Fp Loading

– Body of Connection Loads

– Fastener Loads (3.125 x Body of Connection Loads)

• Direction of Loading– Out-of-Plane

– In-Plane

• Ductility Requirements

42

Design of CFS Curtain Wall Connections (K. Zeydel/A. Kao, 4/11/12)

Page 22: Designing Cold-Formed Steel Curtain Wall · PDF file1 Designing Cold-Formed Steel Curtain Wall Connections Kirsten Zeydel, S.E. Ficcadenti & Waggoner, Consulting Structural Engineers

22

Code Ductility Requirements43

ASCE 7-05 Section 13.5.3

Design of CFS Curtain Wall Connections (K. Zeydel/A. Kao, 4/11/12)

Interpretation of Code Ductility Requirements

Option #1:• Detail corners and intersection with

curtain walls to not collide.

Option #2:• Provide clips from wall stud to base

building that can sustain ductile bending.

• Design connection of clip to base building such that it can resist the Mpcapacity of the clip.

4/11/201244

44

Design of CFS Curtain Wall Connections (K. Zeydel/A. Kao, 4/11/12)

Page 23: Designing Cold-Formed Steel Curtain Wall · PDF file1 Designing Cold-Formed Steel Curtain Wall Connections Kirsten Zeydel, S.E. Ficcadenti & Waggoner, Consulting Structural Engineers

23

Example Slip Clip Design

• Design Loading

PSPW

PS

45

Design of CFS Curtain Wall Connections (K. Zeydel/A. Kao, 4/11/12)

Wind Load Design – Usually Controls for Out-of-Plane Loading

PW

Design Process• Check shear capacity

of screws• Check tension capacity

of clip leg• Check weld from clip to

deck edge

46

Design of CFS Curtain Wall Connections (K. Zeydel/A. Kao, 4/11/12)

Page 24: Designing Cold-Formed Steel Curtain Wall · PDF file1 Designing Cold-Formed Steel Curtain Wall Connections Kirsten Zeydel, S.E. Ficcadenti & Waggoner, Consulting Structural Engineers

24

Seismic Load Design –Controls for In-Plane Loading

Design Options

• Option A:

– Cantilevered Clip w/ No Rotational Restraint

• Option B:

– Cantilevered Clip w/ Some Rotational Restraint

PS

47

Design of CFS Curtain Wall Connections (K. Zeydel/A. Kao, 4/11/12)

Seismic Load Design – Option A

PS

48

Option A: Cantilevered Clip w/ No Rotational Restraint

Design Process

• Check tension capacity of screws.

o Tallow > Pfasteners

o PFasteners = Load from Fp for Fasteners

• Check bending capacity of clip leg.

o Mallow > M

o M = PBody of Conn x e

o PBody of Conn = Load from Fp for Body of Connection

• Check weld from clip to deck edge.

o Use Pfasteners level loads

Design of CFS Curtain Wall Connections (K. Zeydel/A. Kao, 4/11/12)

Page 25: Designing Cold-Formed Steel Curtain Wall · PDF file1 Designing Cold-Formed Steel Curtain Wall Connections Kirsten Zeydel, S.E. Ficcadenti & Waggoner, Consulting Structural Engineers

25

Seismic Load Design – Option B49

Option B: Cantilevered Clip w/ Rotational Restraint

Design Process

• Check tension capacity of screws.

o Tallow > Pfasteners (Include Additional Tension from Force Couple)

o PFasteners = Load from Fp for Fasteners

• Check bending capacity of clip leg.

o Mallow > Mmax

o Mmax from Bending Moment Diagram using PBody of Conn

o Load from Fp for Body of Connection

• Check weld from clip to deck edge.

o To Resist Mmax

o Use Pfasteners level loads

PS

Design of CFS Curtain Wall Connections (K. Zeydel/A. Kao, 4/11/12)

Seismic Load Design – Ductility Check50

Design to have Ductile Bending and Avoid Fastener Failure

• Determine Plastic Moment Capacity of the Clip

o Mp = Z x Fy

• Check Welds to Resist Mp

Mp Clip

Mp ClipForce Couple in Welds

Design of CFS Curtain Wall Connections (K. Zeydel/A. Kao, 4/11/12)

Page 26: Designing Cold-Formed Steel Curtain Wall · PDF file1 Designing Cold-Formed Steel Curtain Wall Connections Kirsten Zeydel, S.E. Ficcadenti & Waggoner, Consulting Structural Engineers

26

Designing for Ductility51

• Design to have ductile bending and avoid fastener failure• Welds

– Work well to resist plastic moment capacity of clips• Shotpins and sometimes expansion anchors

– Frequently do not have enough capacity to resist plastic moment capacity of clips

– For 5” x 10Ga. Clip: Mp = 964#*in therefore, T=C=964#

Mp Clip

Force Couple

Design of CFS Curtain Wall Connections (K. Zeydel/A. Kao, 4/11/12)

Questions?

• Please type your question into the chat box.

Design of CFS Curtain Wall Connections (K. Zeydel/A. Kao, 4/11/12)

52

Page 27: Designing Cold-Formed Steel Curtain Wall · PDF file1 Designing Cold-Formed Steel Curtain Wall Connections Kirsten Zeydel, S.E. Ficcadenti & Waggoner, Consulting Structural Engineers

27

Proprietary Clip Design

• Proprietary clips offer tested solutions that may be more cost effective and easier to install than engineered designs

• Lighter gage steel with features such as embossments, stiffeners, optimized hole layout

• May feature proprietary fasteners that are load-rated higher than standard fasteners

53

Design of CFS Curtain Wall Connections (K. Zeydel/A. Kao, 4/11/12)

Proprietary Clip Design

• Alternative Materials: Conformance to Building Codes

• Acceptance Criteria and Testing Methodology

• Allowable load determination

• Average ultimate value of 3 tests / factor of safety per AISI

• Deflection limit

• Fastener calculation

• Testing of clips

54

Design of CFS Curtain Wall Connections (K. Zeydel/A. Kao, 4/11/12)

Page 28: Designing Cold-Formed Steel Curtain Wall · PDF file1 Designing Cold-Formed Steel Curtain Wall Connections Kirsten Zeydel, S.E. Ficcadenti & Waggoner, Consulting Structural Engineers

28

104.11 Alternative materials, design and methods of construction and equipment

• The provisions of this code are not intended to prevent the installation of any material or to prohibit any design or method of construction not specifically prescribed by this code, provided that any such alternative has been approved.

• An alternative material, design or method of construction shall be approved where the building official finds that the proposed design is satisfactory and complies with the intent of the provisions of this code, and that the material, method or work offered is, for the purpose intended, at least the equivalent of that prescribed in this code in quality, strength, effectiveness, fire resistance, durability and safety.

55

Design of CFS Curtain Wall Connections (K. Zeydel/A. Kao, 4/11/12)

104.11.1 Research reports.

• Supporting data, where necessary to assist in the approval of materials or assemblies not specifically provided for in this code, shall consist of valid research reports from approved sources.

56

Design of CFS Curtain Wall Connections (K. Zeydel/A. Kao, 4/11/12)

Page 29: Designing Cold-Formed Steel Curtain Wall · PDF file1 Designing Cold-Formed Steel Curtain Wall Connections Kirsten Zeydel, S.E. Ficcadenti & Waggoner, Consulting Structural Engineers

29

Accredited Product Certification Bodies57

Design of CFS Curtain Wall Connections (K. Zeydel/A. Kao, 4/11/12)

Acceptance Criteria AC261

• Testing to include CFS structural member, connector, supporting member representative of field conditions

• Minimum of 3 tests, less than 15% variance

• 1/8” deflection serviceability limit

• Factor of safety determination per AISI S100-2007 Section F1

4/11/12

58

Design of CFS Curtain Wall Connections (K. Zeydel/A. Kao, 4/11/12)

Page 30: Designing Cold-Formed Steel Curtain Wall · PDF file1 Designing Cold-Formed Steel Curtain Wall Connections Kirsten Zeydel, S.E. Ficcadenti & Waggoner, Consulting Structural Engineers

30

AISI S100-2007 Section F1

Design of CFS Curtain Wall Connections (K. Zeydel/A. Kao, 4/11/12)

59

Sample Curtain Wall Clips Code Report

60

Design of CFS Curtain WallConnections (K. Zeydel/A. Kao, 4/11/12)

Page 31: Designing Cold-Formed Steel Curtain Wall · PDF file1 Designing Cold-Formed Steel Curtain Wall Connections Kirsten Zeydel, S.E. Ficcadenti & Waggoner, Consulting Structural Engineers

31

Sample Curtain Wall Clips Code Report: Connector Load Table

61

Design of CFS Curtain Wall Connections (K. Zeydel/A. Kao, 4/11/12)

ASCE7-05 Table 13.5-1

Design of CFS Curtain Wall Connections (K. Zeydel/A. Kao, 4/11/12)

62

Page 32: Designing Cold-Formed Steel Curtain Wall · PDF file1 Designing Cold-Formed Steel Curtain Wall Connections Kirsten Zeydel, S.E. Ficcadenti & Waggoner, Consulting Structural Engineers

32

Failure Modes: Connector

4/11/12

Typical bearing failure in stud

Typical screw tilting

63

Design of CFS Curtain Wall Connections (K. Zeydel/A. Kao, 4/11/12)

Failure Modes: Connector

4/11/12

64

Design of CFS Curtain Wall Connections (K. Zeydel/A. Kao, 4/11/12)

Page 33: Designing Cold-Formed Steel Curtain Wall · PDF file1 Designing Cold-Formed Steel Curtain Wall Connections Kirsten Zeydel, S.E. Ficcadenti & Waggoner, Consulting Structural Engineers

33

In-Plane Loads: Design Assumptions65

Design of CFS Curtain Wall Connections (K. Zeydel/A. Kao, 4/11/12)

In-Plane Loads

L1

V1=Ma/L1

L2

V2=Ma/L2V3=2Ma/L3

V3=3V1

L2

66

Design of CFS Curtain Wall Connections (K. Zeydel/A. Kao, 4/11/12)

Page 34: Designing Cold-Formed Steel Curtain Wall · PDF file1 Designing Cold-Formed Steel Curtain Wall Connections Kirsten Zeydel, S.E. Ficcadenti & Waggoner, Consulting Structural Engineers

34

In-Plane Loads: Sample Allowable Loads

Design of CFS Curtain Wall Connections (K. Zeydel/A. Kao, 4/11/12)

Sample Curtain Wall Clips Code Report: Anchorage

68

Design of CFS CurtainWall Connections (K. Zeydel/

A. Kao, 4/11/12)

Page 35: Designing Cold-Formed Steel Curtain Wall · PDF file1 Designing Cold-Formed Steel Curtain Wall Connections Kirsten Zeydel, S.E. Ficcadenti & Waggoner, Consulting Structural Engineers

35

Acceptance Criteria69

Design of CFS Curtain Wall Connections (K. Zeydel/A. Kao, 4/11/12)

Anchorage – Factor of Safety

• Calculated per AISI for steel, screw, or weld failure

• 4.0 for concrete failure• 5.0 for shot pin failure

70

Design of CFS Curtain Wall Connections (K. Zeydel/A. Kao, 4/11/12)

Page 36: Designing Cold-Formed Steel Curtain Wall · PDF file1 Designing Cold-Formed Steel Curtain Wall Connections Kirsten Zeydel, S.E. Ficcadenti & Waggoner, Consulting Structural Engineers

36

Failure Modes: Anchorage

4/11/12

71

Design of CFS Curtain Wall Connections (K. Zeydel/A. Kao, 4/11/12)

Proprietary Clip Design

• Use design values and data from code report published from an accredited agency

• Read the footnotes! (stud thickness, anchorage capacity)

• Contact manufacturer for information on conditions that fall outside scope of code report (anchorage, in-plane loads)

Design of CFS Curtain Wall Connections (K. Zeydel/A. Kao, 4/11/12)

72

Page 37: Designing Cold-Formed Steel Curtain Wall · PDF file1 Designing Cold-Formed Steel Curtain Wall Connections Kirsten Zeydel, S.E. Ficcadenti & Waggoner, Consulting Structural Engineers

37

Engineered vs. Proprietary

• Engineered clips are more time consuming to design but allow for unlimited options and configurations to meet a project’s needs.

• Proprietary clips are easier to design but it is imperative that the engineer understand the parameters by which the in-plane load capacity of the clip was determined.

• The ductility (or lack thereof) of the clips needs to be considered for systems using both engineered and proprietary clips.

73

Connection Challenges74

• Deck edge clips that have the capacity to resist the Fp seismic forces while having the ductility to meet the intent of the code.

• Do not connect to protected zones of the base building’s lateral system (RBS zones, gusset plates, etc.)

• Stickers to beam bottoms and kickers to slabs can have adverse affects on the base building structure if not accounted for in the base building design.

Page 38: Designing Cold-Formed Steel Curtain Wall · PDF file1 Designing Cold-Formed Steel Curtain Wall Connections Kirsten Zeydel, S.E. Ficcadenti & Waggoner, Consulting Structural Engineers

38

Summary75

• Exterior Wall Framing Systems can be quite challenging to design• System must accommodate base building

movement as provided by the SEOR

• Coordinate joint locations and system performances with the architect

• Account for all loading (gravity, wind, and seismic) in the connection designs

• Make sure to design fasteners for the higher Fp value

• Ensure the system meets the ductility requirements of the code

Design of CFS Curtain Wall Connections (K. Zeydel/A. Kao, 4/11/12)

Acknowledgements

• Tom Castle, S.E., Ficcadenti, Waggoner, & Castle

• Tim Stauffer, S.E., Simpson Strong-Tie

• SEAOSC

76

Design of CFS Curtain Wall Connections (K. Zeydel/A. Kao, 4/11/12)