Transcript
  • BASEMENT

    MAIN FLOOR

    MEZZANINE

    ROOF

    100Ø SAN

    NEW 50Ø

    VENT STACK

    EXISTING SANITARY CONFIRM SIZE

    ON SITE PRIOR TO CONNECTION

    OF NEW SANITARY DRAINS

    32Ø VENT

    KS

    CRAWLSPACE

    38Ø SAN

    50Ø VENT

    LUNCH ROOM

    STAFF

    WASHROOM

    DF

    BASEMENT

    MAIN FLOOR

    MEZZANINE

    ROOF

    50Ø VENT

    50Ø VENT

    EXISTING SANITARY CONFIRM SIZE

    ON SITE PRIOR TO CONNECTION

    OF NEW SANITARY DRAINS

    CRAWLSPACE

    NEW

    WASHROOM

    WCWC

    LAV LAV

    LAV

    EX.

    WC

    EX. WC

    EX.

    LAV

    EX.

    LAV

    NEW MS

    CONNECT NEW 50Ø VENT

    TO EXISTING

    EXISTING 50Ø VENT STACK IN

    FALSE COLUMN TO BE RELOCATED

    TO EXTERIOR WALL

    NEW

    WASHROOM

    NEW

    WASHROOM

    100Ø SAN

    32Ø VENT

    50Ø VENT

    50Ø VENT

    WC

    32Ø VENT

    32Ø VENT

    NEW FD

    LAV

    WC

    50Ø VENT

    32Ø VENT

    38Ø VENT

    WC

    LAV

    NEW

    WASHROOM

    100Ø SAN

    COCO

    CO

    38Ø SAN

    50Ø SAN

    50Ø VENT

    WC

    LAV

    38Ø SAN

    100Ø SAN

    32Ø VENT32Ø VENT

    BASEMENT

    MAIN FLOOR

    MEZZANINE

    ROOF

    W

    EXISTING 25Ø DOMESTIC

    WATER SERVICE

    EXISTING 19Ø

    WATER METER

    13Ø DCW &

    DHW TO KS

    CRAWLSPACE

    19Ø DCW TO LAV & WC

    13Ø DCW TO LAV

    13Ø DCW & DHW

    TO LAVATORIES

    19Ø DCW TO LAV & WC

    13Ø DCW TO LAV

    13Ø DCW TO DF

    TO EXISTING

    WASHROOMS

    STAFF

    WASHROOM

    LUNCH ROOM

    NEW

    WASHROOM

    19Ø DCW TO LAV & WC

    13Ø DCW TO LAV

    NEW

    WASHROOM

    EXISTING DOMESTIC WATER SUPPLY

    CONFIRM SIZE AND LOCATION ON

    SITE PRIOR TO NEW CONNECTION

    EXISTING GAS FIRE

    DOMESTIC HOT WATER

    TANK

    13Ø DCW TO MS

    13Ø DHW TO MS

    NEW MOP

    SINK

    19Ø DCW TO

    NEW WATER

    CLOSETS

    This drawing is property of the Architect and cannot

    be reproduced or used without the consent of the

    Architect. The contractor is responsible for checking

    and verifying all levels and dimensions and shall

    report all discrepancies to the Architect and obtain

    clarification prior to commencing work.

    Sheet No:

    1 ISSUED FOR

    CONSTRUCTION

    SEPT 09, 2016

    Project:

    Project Number:

    Drawing Title:

    # Issue/Revision Date

    16054

    6 Fermor Ave., Winnipeg, Manitoba

    St. Vital Library

    THE CITY OF WINNIPEG PLANNING,

    PROPERTY AND DEVELOPMENT

    DEPARTMENT

    MUNICIPAL ACCOMMODATIONS DIVISION

    4TH FLOOR - 185 KING STREET

    R3B 1J1

    Bid Opportunity Number: 768-2016

    MECHANICAL SCHEDULES

    AND SANITARY & DOMESTIC

    WATER SCHEMATICS

    Certificate of Authorization

    HDK Consulting Incorporated

    Date:No. 5539

    04/30/2017

    NTS

    TYPICAL SANITARY SCHEMATIC

    1

    NTS

    TYPICAL SANITARY SCHEMATIC

    2

    NTS

    TYPICAL DOMESTIC WATER SCHEMATIC

    3

    M-9