dpd/pa test report - analog.com · dpd/pa test report ad9375, sky66292-11 rev. | page 1 of 7 ....

7
DPD/PA TEST REPORT AD9375, SKY66292-11 Rev. | Page 1 of 7 DPD/PA TEST REPORT RF Transceiver AD9375 Power Amplifier SKY66292-11 PA Type High Efficiency Semi-Linear PA Transistor Type SWKS HBT Operating Frequency Range (MHz) 2300-2400 Gain (dB) 35.5 Power Added Efficiency 36.6% OP3dB (dBm) +36.1 Supply Voltage 5 V Bandwidths Tested 20 MHz

Upload: others

Post on 22-Sep-2019

21 views

Category:

Documents


0 download

TRANSCRIPT

DPD/PA TEST REPORT AD9375, SKY66292-11

Rev. | Page 1 of 7

DPD/PA TEST REPORT

RF Transceiver AD9375

Power Amplifier SKY66292-11

PA Type High Efficiency Semi-Linear PA

Transistor Type SWKS HBT

Operating Frequency Range (MHz) 2300-2400

Gain (dB) 35.5

Power Added Efficiency 36.6%

OP3dB (dBm) +36.1

Supply Voltage 5 V

Bandwidths Tested 20 MHz

AD9375, SKY66292-11 DPD/PA TEST REPORT

Rev. | Page 2 of 7

SUMMARY

Frequency Output Power (dBm rms)

Signal Bandwidth

Test Signal ACLR +1 (dBc)

ACLR-1 (dBc)

ACLR+2 (dBc)

ACLR-2 (dBc)

Power Added Efficiency (%)

2320 MHz (Bottom)

+27.9

20 MHz E-TM3.1 20 MHz LTE

-49 -49.4 -51.2 -51.6 33.4

2350MHz

(Middle)

+27.8 20 MHz E-TM3.1 20 MHz LTE

-49 -50 -51.5 -52.1 35.4

2390MHz

(Top)

+28 20 MHz E-TM3.1 20 MHz LTE

-51.3 -52.3 -55.2 -54.5 36.1

BLOCK DIAGRAM

AD9375

SKY66292-11

SKY67159-396LF

45mA

30 dB

10 dB

DPD/PA TEST REPORT AD9375, SKY66292-11

Rev. | Page 3 of 7

ACLR RESULTS BOTTOM/MIDDLE/TOP FREQUENCIES 2320 MHZ, 20 MHZ BANDWIDTH ACLR RESULTS

Figure 1. Frequency 2310MHz, 20 MHz E-TM3.1 Signal

Before/After DPD

Output Power (rms)

ACLR+1

(dBc)

ACLR-1

(dBc)

ACLR+2

(dBc)

ACLR-2

(dBc)

ACLR+3

(dBc)

ACLR-3

(dBc)

Drain Current (mA)

PAE (%)

Before DPD +28 -31.7 -33.8 -46 -46.8 -56.3 -55.3 376 33.5

After DPD +27.9 -49 -49.4 -51.2 -51.6 -56.3 -55.9 369 34.1

Table 1. Summary of Results: Frequency: 2310MHz, 20 MHz E-TM3.1 Signal

Signal Used: E-TM3.1, PAR 7.5 dB

Figure 2. AD9375 DPD configuration

AD9375, SKY66292-11 DPD/PA TEST REPORT

Rev. | Page 4 of 7

2350MHZ, 20 MHZ BANDWIDTH ACLR RESULTS

Figure 3. Frequency 2350MHz, 20 MHz E-TM3.1 Signal

Before/After DPD

Output Power (rms)

ACLR+1

(dBc)

ACLR-1

(dBc)

ACLR+2

(dBc)

ACLR-2

(dBc)

ACLR+3

(dBc)

ACLR-3

(dBc)

Drain Current (mA)

PAE (%)

Before DPD +28 -33.5 -35.6 -46.7 -48 -58.4 -56.3 355 35.5

After DPD +27.8 -49 -50 -51.5 -52.1 -55.2 -55.4 340 35.4

Table 2. Summary of Results: Frequency: 2350MHz, 20 MHz E-TM3.1 Signal

Signal Used: E-TM3.1, PAR 7.5 dB

:

Figure 4. . AD9375 DPD configuration

DPD/PA TEST REPORT AD9375, SKY66292-11

Rev. | Page 5 of 7

2390MHZ, 20 MHZ BANDWIDTH ACLR RESULTS

Figure 5. Frequency 2390MHz, 20 MHz E-TM3.1 Signal

Before/After DPD

Output Power (rms)

ACLR+1

(dBc)

ACLR-1

(dBc)

ACLR+2

(dBc)

ACLR-2

(dBc)

ACLR+3

(dBc)

ACLR-3

(dBc)

Drain Current (mA)

PAE (%)

Before DPD 28 -37.2 -38.6 -47.6 -48.5 -60.2 -57.5 354 35.6

After DPD 28 -51.3 -52.33 -55.2 -54.5 -58 -57.5 349 36.1

Table 3. Summary of Results: Frequency: 2390MHz, 20 MHz E-TM3.1 Signal

PA settings: Drain Voltage, Bias currents, Bias Voltages

Signal Used: E-TM3.1, PAR 7.5 dB

:

Figure 6. AD9375 DPD configuration

AD9375, SKY66292-11 DPD/PA TEST REPORT

Rev. | Page 6 of 7

WIDEBAND PLOTS, BOTTOM/MIDDLE/TOP FREQUENCIES

Figure 7. Wideband Spectrum Analyser Plot: Frequency 2310MHZ, 20 MHz E-TM3.1 Signal

Figure 8. Wideband Spectrum Analyser Plot: Frequency 2350MHZ, 20 MHz E-TM3.1 Signal

Figure 9. Wideband Spectrum Analyser Plot: Frequency 2390MHZ, 20 MHz E-TM3.1 Signal

DPD/PA TEST REPORT AD9375, SKY66292-11

Rev. | Page 7 of 7

ACLR VS POUT

Figure 10. ACLR vs Output Power (Middle Frequency)

-70

-65

-60

-55

-50

-45

-40

22 23 24 25 26 27 28 29

ACLR

(dBc

)

Output Power (dBm, rms)

ACLR1 -1 ACLR +1 ACLR -2 ACLR +2