DSE8810 COLOUR AUTO START LOAD SHARE MODULE DSEGenset ® The DSE8810 is an easy-to-use, loadshare module, designed to synchronise and work within a loadshare system of up to 32 generators including electronic and non-electronic engines. The DSE8810 monitors the generator and indicates operational status and fault conditions, automatically starting or stopping the engine on load demand or fault condition. System alarms are annunciated on the LCD screen (multiple language options available), illuminated LED and audible sounder. The event log will record 250 events to facilitate easy maintenance. An extensive number of fixed and flexible monitoring, metering and protection features are included as well as comprehensive communication and system expansion options. Using the DSE PC Configuration Suite Software allows easy alteration of the operational sequences, timers and alarms. With all communication ports capable of being active at the same time, the DSE8810 is ideal for a wide variety of demanding load share applications. KEY LOAD SHARE FEATURES: Sequential set start R.O.C.O.F. and vector shift Generator load demand Automatic hours run balancing Dead bus sensing Bus failure detection Direct governor and AVR control Volts and frequency matching kW and kV Ar load sharing FEATURES ENVIRONMENTAL TESTING STANDARDS ELECTRO-MAGNETIC COMPATIBILITY BS EN 61000-6-2 EMC Generic Immunity Standard for the Industrial Environment BS EN 61000-6-4 EMC Generic Emission Standard for the Industrial Environment ELECTRICAL SAFETY BS EN 60950 Safety of Information Technology Equipment, including Electrical Business Equipment TEMPERATURE BS EN 60068-2-1 Ab/Ae Cold Test -30 o C BS EN 60068-2-2 Bb/Be Dry Heat +70 o C VIBRATION BS EN 60068-2-6 Ten sweeps in each of three major axes 5 Hz to 8 Hz @ +/-7.5 mm, 8 Hz to 500 Hz @ 2 gn HUMIDITY BS EN 60068-2-30 Db Damp Heat Cyclic 20/55 o C @ 95% RH 48 Hours BS EN 60068-2-78 Cab Damp Heat Static 40 o C @ 93% RH 48 Hours SHOCK BS EN 60068-2-27 Three shocks in each of three major axes 15 gn in 11 mS DEGREES OF PROTECTION PROVIDED BY ENCLOSURES BS EN 60529 IP65 - Front of module when installed into the control panel with the supplied sealing gasket. COMPREHENSIVE FEATURE LIST TO SUIT A WIDE VARIETY OF LOAD SHARE APPLICATIONS 1ph 2ph 3ph N DSE2130 DSE2131 DSE2133 DSE2152 DSE2157 DSE2548 2 1ph 2ph 3ph NE 1ph 2ph 3ph N RS232 AND RS485 DSENET ® EXPANSION USB PORT USB HOST CONFIGURABLE INPUTS DC OUTPUTS ANALOGUE SENDERS EMERGENCY STOP DC POWER SUPPLY 8-35V 7 OTHER D + W/L ETHERNET 11 2 23 2 485 6 4 PC MODBUS MODEM BUS SENSING VOLT FREE OUTPUTS GENERATOR SENSING CHARGE ALTERNATOR ELECTRONIC ENGINES MAGNETIC PICK-UP VOLTS CURRENT + + ISSUE 1 MSC 8x60 8x10 8x80 8x10 8x60 DEUTZ ISUZU PERKINS CATERPILLAR MTU VOLVO CUMMINS SCANIA FUEL & CRANK OUTPUTS FLEXIBLE WITH CAN DSE8810 PENDING

Upload: pedro-bortot

Post on 12-Jan-2016

218 views

Category:

Documents


0 download

DESCRIPTION

energia

TRANSCRIPT

Page 1: Dse8810 Data Sheet (Usa)

DSE8810COLOUR AUTO START LOAD SHARE MODULE

DSEGenset

®

The DSE8810 is an easy-to-use,loadshare module, designed tosynchronise and work within aloadshare system of up to 32generators including electronic andnon-electronic engines.

The DSE8810 monitors the generatorand indicates operational status andfault conditions, automaticallystarting or stopping the engine onload demand or fault condition.

System alarms are annunciated onthe LCD screen (multiple languageoptions available), illuminated LEDand audible sounder.

The event log will record 250 events tofacilitate easy maintenance. Anextensive number of fixed andflexible monitoring, metering andprotection features are included as well as comprehensivecommunication and systemexpansion options.

Using the DSE PC ConfigurationSuite Software allows easy alterationof the operational sequences, timersand alarms. With all communicationports capable of being active at thesame time, the DSE8810 is ideal for awide variety of demanding load shareapplications.

KEY LOAD SHARE FEATURES:• Sequential set start• R.O.C.O.F. and vector shift• Generator load demand• Automatic hours run balancing• Dead bus sensing• Bus failure detection• Direct governor and AVR control• Volts and frequency matching• kW and kV Ar load sharing

FEATURES

ENVIRONMENTAL TESTING STANDARDS

ELECTRO-MAGNETIC COMPATIBILITYBS EN 61000-6-2EMC Generic Immunity Standard for the Industrial EnvironmentBS EN 61000-6-4EMC Generic Emission Standard for the Industrial Environment

ELECTRICAL SAFETYBS EN 60950Safety of Information Technology Equipment, including Electrical Business Equipment

TEMPERATUREBS EN 60068-2-1Ab/Ae Cold Test -30 oCBS EN 60068-2-2Bb/Be Dry Heat +70 oC

VIBRATIONBS EN 60068-2-6Ten sweeps in each of three major axes5 Hz to 8 Hz @ +/-7.5 mm, 8 Hz to 500 Hz @ 2 gn

HUMIDITYBS EN 60068-2-30Db Damp Heat Cyclic 20/55 oC@ 95% RH 48 HoursBS EN 60068-2-78Cab Damp Heat Static 40 oC@ 93% RH 48 Hours

SHOCKBS EN 60068-2-27Three shocks in each of three major axes15 gn in 11 mS

DEGREES OF PROTECTIONPROVIDED BY ENCLOSURESBS EN 60529IP65 - Front of module when installed into thecontrol panel with the supplied sealing gasket.COMPREHENSIVE FEATURE LIST TO SUIT A WIDE VARIETY

OF LOAD SHARE APPLICATIONS

1ph2ph3phN

DSE2130DSE2131DSE2133DSE2152DSE2157DSE2548

2 1ph2ph3phNE

1ph2ph3phN

RS232 ANDRS485

DSENET®

EXPANSIONUSBPORT

USBHOST

CONFIGURABLEINPUTS

DC OUTPUTS ANALOGUESENDERS

EMERGENCY STOP

DC POWER SUPPLY 8-35V

7

OTHER

D +W/L

ETHERNET

112

232 485

6 4

PCMODBUSMODEM

BUSSENSING

VOLT FREEOUTPUTS

GENERATOR SENSING CHARGEALTERNATOR

ELECTRONIC ENGINES

MAGNETICPICK-UP

VOLTSCURRENT

+

+

ISSUE 1

MSC

8x60 8x10 8x80 8x10 8x60

DEUTZISUZUPERKINSCATERPILLARMTUVOLVOCUMMINSSCANIA

FUEL & CRANKOUTPUTSFLEXIBLE WITH CAN

DSE8810

PENDING

Page 2: Dse8810 Data Sheet (Usa)

KEY FEATURES• Configurable inputs (11)• Configurable outputs (8)• Built-in governor and AVR control• Comprehensive electrical

protection• Comprehensive loadshare

capabilities• RS232, RS485 & Ethernet remote

communications• Modbus RTU/TCP support • Back-lit LCD graphical display• Configurable display languages• Audible alarm• Reduced file transfer time• Engine protection• Fault condition notification to

a designated PC• Compatible with DSE8700 &

DSE8600 Series• Front panel editing with PIN

protection• Flexible sender inputs• Configurable timers and alarms• 3 configurable maintenance alarms• Multiple date and time scheduler

• Configurable event log (250)• Easy access diagnostic page• CAN and Magnetic Pick-up/Alt.

sensing• Fuel usage monitor and low fuel

alarms• Manual fuel pump control • “Protections disabled” feature• kW overload protection• Reverse power protection• Power monitoring (kW h, kV Ar, kV

A h, kV Ar h)• Load switching (load shedding

and dummy load outputs)• Unbalanced load protection• Independent Earth Fault trip• USB connectivity• Backed up real time clock• Fully configurable via DSE

Configuration Suite PC software• Advanced SMS messaging

(additional external modemrequired)

• Start & stop capability via SMSmessaging

• Additional display screens to help

with modem diagnostics• DSENet® expansion compatible• Integral PLC editor

KEY BENEFITS• Dual processor for improved

response• RS232, RS485 & Ethernet can be

used at the same time• High number of inputs and

outputs• Worldwide language support• Data logging & trending• Harmonics display for clear

monitoring*• Modules can be integrated into

building management systems(BMS)

• Licence-free PC software• IP65 rating (with supplied gasket)

offers increased resistance towater ingress

• PLC editor allows userconfigurable functions to meetspecific application requirements

*Available soon

DSE8810COLOUR AUTO START LOAD SHARE MODULE

®

DSEGenset

FEATURES

SPECIFICATION

DC SUPPLYCONTINUOUS VOLTAGE RATING8 V to 35 V continuous

CRANKING DROPOUTSAble to survive 0 V for 50 mS, providingsupply was at least 10 V before dropout andsupply recovers to 5 V. This is achievedwithout the need for internal batteries

MAXIMUM OPERATING CURRENT600 mA at 12 V, 300 mA at 24 V

MAXIMUM STANDBY CURRENT330 mA at 12 V, 160 mA at 24 V

CHARGE FAIL/EXCITATION RANGE0 V to 35 V

OUTPUTSOUTPUT A (FUEL)15 A DC at supply voltage

OUTPUT B (CRANK)15 A DC at supply voltage

OUTPUTS C & D8 A AC at 250 V AC (Volt free)

AUXILIARY OUTPUTS E TO J2 A DC at supply voltage

GENERATOR & BUSVOLTAGE RANGE 15 V to 333 V AC (L-N)

FREQUENCY RANGE3.5 Hz to 75 Hz

MAGNETIC PICK-UPVOLTAGE RANGE+/- 0.5 V to 70 V

FREQUENCY RANGE10,000 Hz (max)

BUILT-IN GOVERNOR CONTROLMINIMUM LOAD IMPEDANCE 1000ΩFully isolated

GAIN VOLTAGE0 V to 10 V DCFully isolated

OFFSET VOLTAGE+/- 10 V DCFully isolated

BUILT-IN AVR CONTROLMINIMUM LOAD IMPEDANCE1000ΩFully isolated

GAIN VOLTAGE0 V to 10 V DCFully isolated

OFFSET VOLTAGE+/- 10 V DCFully isolated

DIMENSIONSOVERALL245 mm x 184 mm x 50 mm9.6” x 7.2” x 2”

PANEL CUTOUT220 mm x 160 mm8.7” x 6.3”

MAXIMUM PANEL THICKNESS8 mm0.3”

STORAGE TEMPERATURE RANGE-40 oC to +85 oC

DEEP SEA ELECTRONICS PLC UKHighfield House, Hunmanby Industrial Estate, Hunmanby YO14 0PHTELEPHONE +44 (0) 1723 890099 FACSIMILE +44 (0) 1723 893303EMAIL [email protected] WEBSITE www.deepseaplc.com

DEEP SEA ELECTRONICS INC USA3230 Williams Avenue, Rockford, IL 61101-2668 USATELEPHONE +1 (815) 316 8706 FACSIMILE +1 (815) 316 8708EMAIL [email protected] WEBSITE www.deepseausa.com

RELATED MATERIALSTITLE PART NO’SDSE8810 Installation Instructions 053-137DSE88xx Operator Manual 057-163DSE88xx PC Configuration Suite Manual 057-164

055-116/03/12 (1) USRegistered in England & Wales No.01319649VAT No.316923457

Deep Sea Electronics Plc maintains a policy of continuous development and reserves the right to changethe details shown on this data sheet without prior notice. The contents are intended for guidance only.