eds 05-0001 0354 - uk power networkslibrary.ukpowernetworks.co.uk/.../eds+05-0001-0354.pdf · eds...
TRANSCRIPT
SCALE
DRAWING NO.
SITE
A
Date
ORIGINAL
Checked
Approved
Version
Version DESCRIPTIONDesigned
Drawn
@ A3
Version
A
NTS
01/04/2014
EDS 05-0001 0354
N.E.W.
STANDARD SCHEME SCHEMATIC
K.M.B.
P.G.B.
STANDARD
7
11
3
6.G
CSR.
X2X1
AUTO IND
CLLP1.
X2X1
MAN IND
CLLP2.
113
15.E
SMR.
113
15.E
SAR.
RAISE LOWER
IN PROGRESS
RAISELOWER
VMPR.
14
10
9
24
8
AUTOMAN
VMPR.
11 12
13
8
12
4
6.G
CSR.
113
15.F
SRR.
HI LIMIT
LO LIMIT
VMPR.
15
17
16
18
LOCK OUT
PSU
VMPR.
19
3
5
4
20
E
PAS
mA
mA
mA
ACTCOM
10
4-20
20
COMTP-
TP
TP+
PSU
TPIT.
1 2
8
9
3
4
5
7
10
126
VAR.TAP
POSITION
INDICATOR
LO
HI
VMPR.
27
26
25
MPRL5*
VT
MONITOR
INDICATOR
VMPR.
21C
21B
21A
TB.
27 28
TB.
25 26
26A26B
SLK.
GND
2A GLF1
2A GLF3
E30*
E50*
F11*
F50*
N309*
N313*
N72*
N71*
N74*
N73*
N76*
N178*
N179*
A2A1
SUPPLY FAIL TIMER
SFT.
N309*
N211*
N313*
F110*
F150*
XE#2
XE#1
D31*
D30*
D90*
L3*
2A GLF4
13
6.G
CSR.
31
10.I
FRB.
1715
11.E
FRA.
X101*
X103*
X105*
X107*
X109*
X111*
X113*
X115*
X547*
X549*
SAR.
SUPERVISORY AUTO RELAY
21
SMR.
SUPERVISORY MAN RELAY
21
SRR.
SUPERVISORY RAISE RELAY
21
SLR.
SUPERVISORY LOWER RELAY
21
RST
SET
10
CSR.
CONTROL SELECT RELAY
1
14
2
LK2
ELK.
27B 27A
RE
MO
TE
LO
CA
L
LSS
ALARM
VMPR.
6 7
P2
P1
CT
LDC CT
S1
S3
S2
'b' phase
FRA.
FLAG RELAY LEFT HAND
TAP CHANGE FAULT
27 28
FRB.
FLAG RELAY RIGHT HAND
AVC FAULT
13 14
OD1
OD2
LINK LINK
J1 J2
X163*
X161*
13
15.D
LRR2
13
15.C
LRR1
15.D
LRR2
15.C
LRR1
N75*
113
15.F
SLR.
15.G
ASR.
TB.
1 2
TB.
3 4
TB.
5 6 F51*
F30* F31*
N303*
N306*
N307
N77*
ALARM
VCR.
D4 D5
D1*
D2*
D3*
D4*
AC
DC
15
16
3
1
SCT
D34*
ITX.
P2
P1
S1
S2
XC92
XC91
D5*
D6*
2A GL
F8 LK9
110
VA
C S
UPPL
Y -
LO
WER T
AP
RAIS
E T
AP
TA
P L
OC
K O
UT
CO
NT
ROL R
EM
OTE
110
VA
C S
UPPL
Y
POSIT
ON I
ND T
AP HI
POSITIO
N I
ND C
OM
POSITIO
N I
ND T
AP L
O
SLK
ELK
P2
P1
LOAD CT
S1
S3
S2
'b' phase
FEEDER INTERPOSING CT
ITX
P2
P1
S1
S2
LINK
TERMINATOR
LINE
PAIR CABLE
SCREENED TWISTED
. .BKBK..
1
-PSU1
DC INPUT
12-16VDC OUTPUT 2A
E
N
L
+
-
SUPERTAPP N+ RELAY FOR 2ND TRANSF.
-VCR.
G1
G2
G3
G4
SUPERTAPP N+ RELAY
FOR 1ST TRANSF
VCR.
G1
G2
G3
G4
SUPERTAPP N+ RELAY FOR ADDITIONAL TRANSFORMER(S)
VCR.
G1
G2
G3
G4
LINK
TERMINATOR
LINE
SLK
ELK
P2
P1
LOAD CT
S1
S3
S2
'b' phase
FEEDER INTERPOSING CT
ITX
P2
P1
S1
S2
:X5
V
28NORMAL SETTINGS SELECTED
(GEN AVC OUT OF SERVICE)
:X5
V
29ALT SETTINGS SELECTED
(GEN AVC IN SERVICE)
V
:X5
V
20
:X5
V
19
:X5
V
33TAP CHANGE FAULTY
:X5
V
32VOLTAGE CTRL FAULTY
:X5
V
31TAP CHANGE PROGRESS
:X5
V
30TAP CHNGER LOCAL CTRL
:X5
V
27REM/MAN V CTRL SELECTED
:X5
V
26AUTO V CTRL SELECTED
:X5
V
256% ON IND
:X5
V
246% OFF IND
:X5
V
233% ON IND
:X5
V
223% OFF IND
:X5
V
21
:X5
V
:X5
V
:X5
V
:X5
V
:X5
V
:X5
V
V
V
V
V
V
V
V
V
:X5
V
29
VT ANALOGUE +VE
:X5
V
30
VT ANALOGUE -VE
13
15.G
ASR.
X1*
:X5
V
25
+VE
ANALOGUE
TAP POSITION
:X5
V
26
-VE
ANALOGUE
TAP POSITION
:X1
V
23
:X1
V
22
:X1
V
21
:X1
V
19
:X1
V
20
V V
V
:
:
: 2D6
: 2D5
:
:
:
:
:X3
2
:X24
:X23
:X22
:X21
:
R
VT "A" PH VT
:
R
VT "A" PH VT
:
R
VT "A" PH VT
D
D
K
K
:X3
2
V
110VDC +VE
V
110VDC -VE
110VDC +VE
BCR
BUS COUPLER STATUS RELAY
A1 A2
:X7
V
5
:X7
V
6
2A GL
F25 BC
CB AUX "B" CONTACT
N105LK26
1411
10.F
BCR
BK..
F51**
F11**
E10* F10*
WH..WH.. WH..
LK7
LK6
F51*
2-11.F
F11*
2-11.F
2-11.H
2-11.H
2-7.I
2-10.I
F52*
F12*
2A GL
F10 LK11
PSU A6A4
VCR.
A3 A2
A1 A2
RAISE
LOWERC3
VCR.
C2 C4
C1
V OFFSET 1
V OFFSET 2
V OFFSET 3
NON-AUTO
AUTO
PARAM SELECT
VCR.
F1 F7
F8
F2
F3
F4
F5
F6
HEALTHY
ALARM
VCR.
D1 D2
D3
CT1-S1
CT1-S2
CT2-S1
CT2-S2
CT3-S1
CT3-S2
B6
B5
VCR.
B1
B2
B3
B4
VT1+
VT1
VT2+
VT2
VCR.
E1
E2
E3
E4
L2*
L1*
N102*N101*
131211
+-
-DTU
15
14
N109N110
87
65
RB.
200R
43
21
RB.
200R
XT2**
4.N
2-4.N
5.N
2-5.N
XT1
XT2*
XT1
:X1
V
24
:X1
V
25
D33**
D36**
:X527
SUMMATED LOAD
ANALOGUE +VE
:X5
V
28
SUMMATED LOAD
ANALOGUE -VE
2P2
2P1
2P1
CTSI
1P2
1P12P2
D33*
D36*
8.L
2221
CDS
CIL
L N
H1 H2
4A GL
F33
4A GL
F34H24H23 H25
:X12
V2
:X12
V1
2A GLF5
AC
DC
VTT.
16
15
5
2
V
110
VA
C S
UPPL
Y
XT2*
110VDC -VE
110VAC 110VAC
N.E.W.
L1*
X1*
DRIVE MECHANISM CONTROL CIRCUITS
DRIVE MECHANISM - SEE MANUFACTURER'S DRAWINGS FOR
CONNECTIONS TO MASCHINENFABRIK REINHAUSEN (MR) ED100
N194*N213*N211*N209* N154* N153* N195*N173*N70*
9.O
9.O
XT1*XT1A*
V
RST
SET
10
1
14
2
RST
SET
10
1
14
2
RST
SET
10
1
14
2
V
V
W54*
W52*
W58*
W56*
W62*
W64*
W66*
W68*
W96*
W94*
W53* W54*
W51* *W52
3% RED'N ON -VE
3% RED'N OFF -VE
3% RED'N ON +VE
3% RED'N OFF +VE
MR ED100 DRIVE MECH BOX INTERFACESUPERTAPP N+ AVR
STANDARD AVC SCHEMATIC
59
5
5
5
9
9
9
6% RED'N ON +VE
6% RED'N OFF +VE
W57*
W55* W56*
W58*
6% RED'N ON -VE
6% RED'N OFF -VE
W61* W62*
W63* W64*
W65*
W67* W68*
W66*
W95*
W93* W94*
W96*
IND COMMON
SELECT AUTO CTRL +VE
SELECT MAN/REM CTRL +VE
RAISE TAP +VE
LOWER TAP +VE
(ENABLE GEN AVC)
ALTERNATIVE SETTINGS ON +VE
(DISABLE GEN AVC)
ALTERNATIVE SETTINGS OFF +VE
SELECT AUTO CTRL -VE
SELECT MAN/REM CTRL -VE
RAISE TAP -VE
LOWER TAP -VE
(ENABLE GEN AVC)
ALTERNATIVE SETTINGS ON -VE
(DISABLE GEN AVC)
ALTERNATIVE SETTINGS OFF -VE
1615
6.N
SFT.
N38*
DS
S (S15)
VV V V V V VV VV
110V DC SUPPLY
TO SCADA
SCADA
TO
TRANSFORMER
LDC CT FOR 2ND
FEEDER CIRCUIT / GENERATOR PANEL
MARSHALLING KIOSK
LINK MUST ONLY BE FITTED ON THE LAST RELAY
RELAY, TERMINAL FOR TERMINAL. THE TERMINATOR
TRANSFORMER IS LOOPED FROM THE PRECEDING
THE CAN BUS WIRING FOR EACH ADDITIONAL
NOTE 2;
FEEDER CIRCUIT / GENERATOR PANEL
OPTIONAL VT TRANSDUCER
MEASUREMENTS IF REQUIRED
TYPICAL ADDITIONAL CT
MARSHALLING KIOSK
SEE NOTE 1
SEE NOTE 2
FOR COMPONENTS - SUFFIX USING '.' AS A SEPARATER, WITH TRANSFORMER No. (WITHOUT THE 'T') E.G. 1, 1A, 2, 2A ETC
REPLACE '**' SUFFIX WITH TAG TO INDICATE 2ND TRANSFORMER
FOR WIRE Nos - REPLACE '*' SUFFIX WITH TAG TO INDICATE 1ST TRANSFORMER IN THE COMMON RTCP E.G. T1, T1A, T2, T2A ETC
BUS COUPLER CB BCR
1411
2.L
12 SP
2421
2-2.M
22 SP
3431 SP
32
EQUIPMEMT
OPTIONAL DATA TRANSMISSION
SEE NOTE 3
& VCR2
BUS CABLE IS CONNECTED DIRECTLY BETWEEN VCR1
IF DATA TRANSMISSION IS NOT REQUIRED THE CAN
NOTE 3;
SAR.
113SP
13
124SP
14
75SP
9
86SP
10
SEE NOTE 1
SEE NOTE 1
SEE NOTE 2
RELEVANT TRANSFORMER
REPLACE '#' WITH 1, 2, 3, OR 4 FOR
SMR.
113SP
13
124SP
14
75SP
9
86SP
10
SRR.
113SP
13
124SP
14
75SP
9
86SP
10
SLR.
113SP
13
124SP
14
75SP
9
86SP
10
CSR.
73SP
11
84SP
12
95SP
13
SFT.
1815SP
16
2825SP
26
110V AC LIGHT/HEATER SUPPLY
FRA.
15 17 15.L
19 21 SP
23 25 SP
16 18 SP
20 22 SP
24 26 SP
FRB.
1 3 15.K
5 7 SP
9 11 SP
2 4 SP
6 8 SP
10 12 SP
X1:16X1:15
S39M:2 X1:14S39M:1 S39M:3 X1:13 X1:12 X1:276 X1:15 X1:10 X1:11 X1:07
X6:1 X6:3
X6:2 X6:4
X1:13 X1:14
ENVOY
LOOP TO
0-10mA
TRANSMISSION EQUIPMENT IS FITTED
ONLY REQUIRED IF DATA
P
1
O
N
2 3
M
L
K
J
I
H
G
F
E
D
C
B
A
1 2 3
4 5 6 7 10 11 12 13 14 15 16
4 5 6 7 8 9 10 11 12 13 14 15 16
P
O
N
M
L
K
J
I
H
G
F
E
D
C
B
A
3% LOAD REDUCTION
LRR2
73SP
11
84SP
12
95SP
13
LRR1
6% LOAD REDUCTION LRR2
ASR
X5:10
ASR
73SP
11
84SP
12
95SP
13
3 7
LRR1
73SP
11
84SP
12
95SP
13
3 7
73
ALTERNATIVE SETTINGS RELAY
BELOW.
ALTERNATIVE COIL VOLTAGE IN THE COMPONENT LIST
VOLTAGE, APPLICATION/DESIGN ENGINEER TO SPECIFY
48VDC. FOR SCADA RTU'S USING A DIFFERENT
SCADA CONTROL RELAY COILS ARE SPECIFIED AT
NOTE 4;
4 AND 5
SEE NOTES:
TEC/RTU
TO SCADA
NEW AVC PANEL
RTU LOCATED AT THE SUBSTATION RECEIVING THE
COMMONING WIRES AT X5 RAIL TO SUIT THE SCADA
SITE ENGINEER TO APPLY SCADA CONTROLS
NOTE 5;
1 AMP CT REQUIRES 5 TURNS
5AMP LDC CT REQUIRES 1 TURN ON THE PRIMARY, A
OF THE CT FEEDING IT IN THE RATIO OF 5:1 E.G. A
INTERPOSING CT IS DEPENDENT ON THE SECONDARY
THE No OF TURNS ON THE PRIMARY FOR EACH
NOTE 1;
65
(S32A)(Q1)
41 42
TIP
73SP
5
84SP
6
TIPR
X1:19
TIPR
4.D
3 7
5
X1:300
X1:02X1:06X1:05X1:07X1:03X1:04X1:01X1:11X1:10X1:09
X1:241 X1:215
TIPR
4.D
48
6
X1:17 X1:18
NO
C
03/04/14
03/04/14
COMPONENTS LIST
ITEM DESCRIPTION MFG CAT
FUSES & LINKS
F1 (F13) 'A' PHASE VT FUSE 110V AC NIT2 FUSE IN 20A FUSE CARRIER GEC RS20PG-BK
LK2 (LK14) 'B' PHASE VT LINK 110V AC SOLID BAR IN 20A FUSE CARRIER GEC RS20PG-WH
F3 (F15) 'C' PHASE VT FUSE 110V AC NIT2 FUSE IN 20A FUSE CARRIER GEC RS20PG-BK
F4 (F16) 'A' PHASE VT TRANSDUCER FUSE 110V AC NIT2 FUSE IN 20A FUSE CARRIER GEC RS20PG-BK
F5 (F17) 'C' PHASE VT TRANSDUCER FUSE 110V AC NIT2 FUSE IN 20A FUSE CARRIER GEC RS20PG-BK
LK6 2ND TRANSF VT TO 1ST TRANSF VCR A PHASE LINK 110V AC SOLID BAR IN 20A FUSE CARRIER GEC RS20PG-WH
LK7 2ND TRANSF VT TO 1ST TRANSF VCR C PHASE LINK 110V AC SOLID BAR IN 20A FUSE CARRIER GEC RS20PG-WH
F8 (F20) VCR* SUPPLY FUSE 110V DC + NIT2 FUSE IN 20A FUSE CARRIER GEC RS20PG-BK
LK9 (LK21) VCR* SUPPLY LINK 110V DC - SOLID BAR IN 20A FUSE CARRIER GEC RS20PG-WH
F10 (F22) ALARM CIRCUIT FUSE 110V DC + NIT2 FUSE IN 20A FUSE CARRIER GEC RS20PG-BK
LK11 (LK23) ALARM CIRCUIT LINK 110V DC - SOLID BAR IN 20A FUSE CARRIER GEC RS20PG-WH
LK18 1ST TRANSF VT TO 2ND TRANSF VCR 'A' PHASE LINK 110V AC SOLID BAR IN 20A FUSE CARRIER GEC RS20PG-WH
LK19 1ST TRANSF VT TO 2ND TRANSF VCR 'C' PHASE LINK 110V AC SOLID BAR IN 20A FUSE CARRIER GEC RS20PG-WH
F25 BCR & DTU SUPPLY FUSE 110V DC+ NIT2 FUSE IN 20A FUSE CARRIER GEC RS20PG-BK
LK26 BCR & DTU SUPPLY LINK 110V DC - SOLID BAR IN 20A FUSE CARRIER GEC RS20PG-WH
F33 + F34 CUBICLE LIGHT SUPPLY FUSE 110V AC NIT4 FUSE IN 20A FUSE CARRIER GEC RS20PG-BK
COMMON PANEL COMPONENTS
BCR BUS COUPLER STATUS RELAY 110VDC 3C/O FINDER 60.13.9.110.0000
CDS CUBICLE DOOR SWITCH DOOR OPERATED LIMIT SWITCH LOVATO KXMS
CIL CUBICLE ILLUMINATION LIGHT 100W BULKHEAD JCC JC40007 GLS100W E27
CTSI LDC CT SUMMATION INTERPOSER 5A+5A+……/5A DK MORIATY DKM 1152
DTU DATA TRANSMISSION UNIT ENVOY NORTECH FP1026
PSU1 12VDC POWER SUPPLY UNIT 100-240V AC TO 12VDC 2A 24W TRACO POWER TCL24-112
LRR1 3% LOAD REDUCTION RELAY 48VDC LATCHING 3C/O +1NC ARTECHE BF-3 (DC)
LRR2 6% LOAD REDUCTION RELAY 48VDC LATCHING 3C/O +1NC ARTECHE BF-3 (DC)
SCT SUMMATED CURRENT TRANSDUCER 7.5A AC INPUT 0-15mA DC OUTPUT ELTIME ECCC-CX-E0-X15-F50
PANEL COMPONENTS FOR EACH TRANSFORMER ( * SUFFIX FOR INDIVIDUAL TRANSFORMER)
ASR* ALTERNATIVE SETTINGS RELAY 48VDC LATCHING 3C/O +1NC ARTECHE BF-3 (DC)
CSR* CONTROL SELECT RELAY 3P C/O CUT THROAT 110VAC LATCHING PLUG IN ARTECHE BF-3 (110VAC)
ELK* LDC CT EARTH LINK RAIL MOUNTED LINK TERMINAL WEIDMULLER SAKA10
FRA*/ FRB* DUAL FLAG RELAY 110VDC COILS AREVA MVAA21T1BA0795A
H1* AUTO CONTROL INDICATOR WHITE 22MM 48-115VAC LED TELEMECANIQUE ZB4-BVG01+ZB4-BV13
H2* MANUAL CONTROL INDICATOR WHITE 22MM 48-115VAC LED TELEMECANIQUE ZB4-BVG01+ZB4-BV13
ITX* INTERPOSING TRANSFORMER 10A/10mA 0.030VA FUNDAMENTALS FP1030
RB* RESISTOR BLOCK 2 X 400R .5W RESISTORS MOUNTED IN DOUBLE STACK TERMINALS ENTRELEC M4/6.DE1
SAR* SUPERVISORY AUTO RELAY 4P C/O 48VDC PLUG IN MORS SMITT DU202
SFT* SUPPLY FAIL TIMER 0-10MIN TRUE OFF DELAY TELEMECANIQUE RE7RB13MW
SLK* LDC CT SHORTING LINK RAIL MOUNTED LINK TERMINAL WEIDMULLER SAKA10
SLR* SUPERVISORY LOWER RELAY 4P C/O 48VDC PLUG IN MORS SMITT DU202
SMR* SUPERVISORY MANUAL RELAY 4P C/O 48VDC PLUG IN MORS SMITT DU202
SRR* SUPERVISORY RAISE RELAY 4P C/O 48VDC PLUG IN MORS SMITT DU202
TB* TEST BLOCK FRONT FLUSH MOUNTED AREVA MMLG01R1AA0001D
TIPR* TAP IN PROGRESS RELAY 110VAC INSTANTANEOUS 2C/O ARTECHE RD-2 (AC)
TPIT* TAP POSITION INDICATION TRANSDUCER MULTI mA OUTPUT RAIL MOUNTED FUNDAMENTALS FTPT/2
VCR* VOLTAGE CONTROL RELAY FRONT FLUSH MOUNTED FUNDAMENTALS FP1014-V2C3
VMPR* VOLTAGE MONITOR & PROTECTION RELAY FRONT FLUSH MOUNTED FUNDAMENTALS RTMU/2M
VTT* VT TRANSDUCER 110VA AC INPUT 0-10mA DC OUTPUT ELTIME EVCC-P1-E0-X10-F50
PANEL FIELD WIRING TERMINALS
-X1 (X7) TAP CHANGE CONTROL WEIDMULLER WDU6/SL EN
-X2 (X8) FEEDER CT CONNECTIONS WEIDMULLER WDU6/SL EN
-X3 (X9) INTERPOSING LDC CT CONNECTION WEIDMULLER WDU6/SL EN
-X4 (X10) SPARE WEIDMULLER WDU6/SL EN
-X5 (X11) SCADA CONNECTIONS WEIDMULLER WTR4
-X6 110VDC ALARM SUPPLY WEIDMULLER WDU6/SL EN
-X12 110VAC CUBICLE LIGHT SUPPLY WEIDMULLER WDU6/SL EN
EXTERNAL COMPONENTS
BC BUS COUPLER CB SWITCHGEAR
DSS DIRECTIONAL SEQUENCE SWITCH PART OF DRIVE MECHANISM
LSS LOCAL SELECTOR SWITCH IN MARSHALLING KIOSK
MPR MOTOR PROTECTION BREAKER IN MARSHALLING KIOSK
NOTE: ITEM Nos. IN BRACKETS ARE FOR 2ND TRANSFORMER COMPONENTS IN THE PANEL
D37
D38
X5:1
X5:2
X5:3
X5:4
X5:5
X5:6
X5:7
X5:8
X5:9
X5:11
X5:12
13
14
15
16
17
18