eia & emp for 100 mw thermal power plant at...
TRANSCRIPT
ANNEXURE
Annexure 1: Production Details
Annexure 2: Site Location Map
Annexure 3: Site Layout Map & Area breakup for Terminal
Annexure 4: Operation Philosophy
Annexure 5: Copy of Consent to Operate
Annexure 6: Storage tank Details
Annexure 7: Water consumption & Waste water generation details
Annexure 8: Fuel consumption details
Annexure 9: Hazardous waste generation details
Annexure 10: Stack details
Annexure 11: Land Possession documents
Annexure 1: Production Details
Table 0-1: Details of Existing & Additional Chemicals Storage
Material
Existing Additional Total
Storage
Capacity
(KL)
Nos. of
Storage
Tanks
Storage
Capacity
(KL)
Nos. of
Storage
Tanks
Storage
Capacity
(KL)
Nos. of
Storage
Tanks
HSD
11000 1 - -
42396 4 13791 1 - -
10805 1 - -
6800 1 - -
MS
9163 1 - -
31952 4 8827 1 - -
6981 2 - -
SKO 8385 2 - -
13615 3 5230 1 - -
LDO 5200 1 - - 5200 1
ATF
16220 2 - -
62072 6
8655 1 - -
7194 1 - -
9783 1 - -
4000 1 - -
EMPTY 180 2 - - 360 2
93-OCTANE 180 1 - - 180 1
ETHANOL 938 2 2000 2 5876 4
Total storage
quantity (KL) 166036 23 4000 2 170036 25
Annexure 2: Site Location Map
Sr. No. Point Latitude Longitude
1 A 28°32'15.97"N 77° 3'37.31"E
2 B 28°32'18.01"N 77° 3'35.83"E
3 C 28°32'26.19"N 77° 3'18.41"E
4 D 28°32'37.89"N 77° 3'27.97"E
5 E 28°32'31.67"N 77° 3'43.50"E
6 F 28°32'29.18"N 77° 3'43.31"E
7 G 28°32'26.39"N 77° 3'40.98"E
8 H 28°32'28.37"N 77° 3'36.88"E
9 I 28°32'21.18"N 77° 3'31.65"E
10 J 28°32'18.92"N 77° 3'35.51"E
11 K 28°32'16.96"N 77° 3'38.70"E
Annexure 3: Site Layout Map
The Total site area is 71 Acres. The area details of the existing facility and the additional facilities are
given below in the Table.
Table 0-2: Area breakup for terminal
S. no. Description Area, m2(Tentative) % of Total Area
1 Storage tank farm area (existing) 53608 18.7
2 Storage tank farm area (additional) 4547 1.6
3 Utility area (FE/PH, PH) 1161 0.4
4 Administrative Building 600 0.2
5 Building Blocks 6515 2.3
6 Parking 240 0.1
7 Roads 5270 1.8
8 Green belt area 16721 5.8
9 Fire water storage area 1325 0.5
10 Loading Unloading area 2446 0.9
11 Misc ( TLF, Open space, scrap yard, lube oil, TT
Parking, Officers coloney etc…) 194894 67.8
Total 287327 100.0
Annexure 4: Operation Philosophy
Delhi Terminal, Bijwasan is a Petroleum Product Storage Terminal of Indian Oil Corporation Limited,
located in New Delhi, the Capital City of Republic of India. The terminal operates in 3 shifts and its
activity involves receipt, storage and distribution of finished petroleum product (Motor Gasolene, Gas
Oil and Aviation Fuel). The product is received from Mathura & Panipat Refineries through cross
country pipelines. There is a provision to receive LDO & Aviation Fuel through Tank Wagons as well.
For storage of various products, Delhi Terminal has 23 Storage Tanks. Delivery of product to various
customers is undertaken through pipelines as well as Tank Lorries. The Terminal also handles Ethanol,
which is mixed in a proportion of 10% by volume with Motor Gasoline for dispatches.
At Bijwasan terminal product inlet is through Mathura Jalandhar pipeline which has commenced on
27th
April 1982 & is around 763 kms in length. This pipeline runs around 147 kms from Mathura to
Delhi with a capacity of about 3.70 MMTPA. Storage capacity of terminal is 165720 KLs with 23 tanks
storing different products. On an average 400 T/T were loaded per day with the help of TLF Gantry
with 30 loading bays & 23 pumps for different products at the terminal
The Terminal is operated in accordance with the provisions of licenses and consents granted by
regulatory departments viz. Departments of Petroleum & Explosives Safety Organization, Directorate
of Factories, Manufacture, Storage & Import of Hazardous Chemical Rules & Pollution Control Board
etc. as per the applicable regulatory statutory acts and rules of Govt. of India.
1.1.1 Activities at Terminal
Tank Lorry Loading - MS, HSD, SKO, ATF, LDO
Tank Lorry Unloading : MS, 93 Octane, SKO, Ethanol
Ethanol blending, at TLF
Loading of additive to the additive tank and blending at TLF
Pipeline Receipt through Cross Country Pipeline – MS, HSD, SKO & ATF
Receipt through Tank Wagon (Intermittent) – ATF, LDO
Inter tank transfer
Tank Water Draining Operation
Sampling of Product from Tank after every receipt
Emptying out of Tank at fixed interval for Maintenance/ Cleaning for Quality Control adherence
Opening of Strainers for Cleaning of Strainer’s Filters at fixed interval.
Maintenance and Repair of various Equipments Viz. Pumps, Motors, Fire Engines, Air
Compressors etc.
Process Flow Diagram of the operation at Terminal is enumerated as under:
Figure 3.1: Process Flow Diagram
1.1.2 Ethanol blending process
Nominate the ETHANOL Tank (TK-21 or TK-22) for MS- Ethanol blending at TLF.
Nominate the ETHANOL Pump (E1 OR E2) for pumping ETHANOL to TLF through the nominated
ETHANOL Tank (TK-21 or TK-22).
Carry out gauging of the tanks and upload the gauges in SAP.
Check line up of the nominated tanks & pumps or pump sequence for TLF Operation, by opening
valves which are numbered for Operating sequence as below.
Figure 3.2: Ethanol blending process
Annexure 5: Copy of Consent to Operate
Annexure 6: Storage tank details
S. No. Tank No. Material Physical
State
Hazard
Involve
Storage
Capacity (KL)
Type of Tank
(CR/FR/UG
/AG/SB)
Height (m) Dia (m)
Operating Condition
Press Kg/Cm2 Temp ºC
1 TK1 HSD Liquid Flammable 11000.00 CR 13.75 M 36.00 Atmospheric Ambient
2 TK2 HSD Liquid Flammable 13791.00 CR 14.00 M 36.00 Atmospheric Ambient
3 TK3 HSD Liquid Flammable 10805.00 CR 14.00 M 32.00 Atmospheric Ambient
4 TK4 MS Liquid Flammable 9163.00 FR 12.93 M 32.00 Atmospheric Ambient
5 TK5 MS Liquid Flammable 8827.00 FR 12.48 M 32.00 Atmospheric Ambient
6 TK6 SKO Liquid Flammable 5230.00 CR 14.33 M 22 Atmospheric Ambient
7 TK7 LDO Liquid Flammable 5200.00 CR 14.34 M 22 Atmospheric Ambient
8 TK8 HSD Liquid Flammable 6800.00 CR 13.41 M 26 Atmospheric Ambient
9 TK9 ATF Liquid Flammable 16220.00 CR 14.93 M 38 Atmospheric Ambient
10 TK10 ATF Liquid Flammable 16220.00 CR 15.00 M 38 Atmospheric Ambient
11 TK11 MS Liquid Flammable 6981.00 FR 16.50 M 24 Atmospheric Ambient
12 TK12 MS Liquid Flammable 6981.00 FR 16.50 M 24 Atmospheric Ambient
13 TK13 ATF Liquid Flammable 8655.00 CR 14.75 M 28 Atmospheric Ambient
14 TK14 ATF Liquid Flammable 7194.00 CR 14.55 M 26 Atmospheric Ambient
15 TK15 ATF Liquid Flammable 9783.00 CR 14.55 M 30 Atmospheric Ambient
16 TK16 SKO Liquid Flammable 8385.00 CR 15.00 M 28 Atmospheric Ambient
17 TK17 SKO Liquid Flammable 8385.00 CR 15.00 M 28 Atmospheric Ambient
18 TK18 EMPTY Liquid Flammable 180.00 SB 16.25 M(L) 3.75 Atmospheric Ambient
19 TK19 EMPTY Liquid Flammable 180.00 SB 16.25 M(L) 3.75 Atmospheric Ambient
20 TK20 93-OCTANE Liquid Flammable 180.00 SB 16.25 M(L) 3.75 Atmospheric Ambient
21 TK21 ETHANOL Liquid Flammable 938.00 CR 12.00 M 10 Atmospheric Ambient
22 TK22 ETHANOL Liquid Flammable 938.00 CR 12.00M 10 Atmospheric Ambient
23 TK24 ATF Liquid Flammable 4000.00 CR 14.70 M 20 Atmospheric Ambient
Annexure 7: Water consumption & Waste water generation details
Water will be sourced through Tankers. As the terminal is providing only storage and handling
services, there is no additional water requirement for processing or operation, water is required only
for gardening and domestic purpose. Terminal’s existing water requirement is 50 KLD. After addition
of two new tanks, domestic water consumption will not increase. So after proposed expansion water
consumption will remain same as 50 KLD.
Table 0-3: Water Consumption Details
S. No. Description Water Consumption in KLD
Existing Additional Total
1 Processing 0 0 0
2 Gardening 10 0 10
3 Domestic 40 0 40
Total 50 0 50
There will not be any generation of industrial effluent. Domestic wastewater will be disposed off in
soak pit through septic tank. Break up of wastewater generation along with disposal mode is given
in following table
Table 0-4: Wastewater Generation and disposal
S. No. Description Wastewater Generation in KLD
Disposal Mode Existing Additional Total
1 Industrial Operation 0 0 0 -
2 Gardening 0 0 0 -
3 Domestic 20 0 20 To send to
Septic Tank
Total 20 0 20
Annexure 8: Fuel consumption details
Table 0-5: Fuel Consumption details
Sr. No. Stack Attached to Capacity Stack Nos. Type of Fuel used Fuel consumption
Existing
1 DG set 2 x 750 KVA +
1 x 500 KVA 5 HSD
140 Ltr/hr. at full
load
2 Fire water Engine
pumps 8 x 616 m
3 8 HSD
35 Ltr/hr. at full
load
Additional
No flue gas stack will be added after additional tankage
Annexure 9: Hazardous waste generation details
Table 0-6: Hazardous waste Generation and disposal
S. No. Hazardous
Waste
Hazardous
Waste Category
Quantity in MTPA Management
Existing Proposed Total
1 Used Oil 5.1 60 liters 0.00 60 liters Disposed to
authorized agency
2 Tank cleaning
Sludge 3.3 0.6 0.02 0.62 Internal Bio- remedial
Annexure 10: Stack details
Table 0-7: Stack details
Sr.
No. Stack Attached to Capacity Stack Nos.
Stack Height,
m
Stack Top
Dia, m
Existing
1 DG set As a backup
during emergency
2 X 750 KVA 4 7 6 inch
1 X 500 KVA 1 7 6 inch
2 Fire water Engine
pumps 8 X 616 m3 8 7 6 inch
Proposed
No flue gas stack will be added after proposed expansion
Annexure 11: Land possession documents