elektral a.s

34

Upload: alec-ingram

Post on 31-Dec-2015

52 views

Category:

Documents


0 download

DESCRIPTION

ELEKTRAL A.S. You need 15 minutes for assembling!... Get User’s Manual PLS. Download from our web-site: www.elektral.com.tr. ASSEMBLING & MOUNTING ThruScan. 1. You receive 2 boxes for each metal detector: Main Control & Display Unit Side Panels (Left&Right). ELEKTRAL A.S. - PowerPoint PPT Presentation

TRANSCRIPT

Page 1: ELEKTRAL A.S
Page 2: ELEKTRAL A.S

ELEKTRAL A.S.

ASSEMBLING & MOUNTING ThruScan

You need 15 minutes for assembling!...

Get User’s Manual

PLS. Download from our web-site: www.elektral.com.tr

You receive 2 boxes for each metal detector:

• Main Control & Display Unit

• Side Panels (Left&Right)

1

Page 3: ELEKTRAL A.S

ELEKTRAL A.S.

ASSEMBLING & MOUNTING ThruScan

You need 15 minutes for assembling!...

Get User’s Manual

PLS. Download from our web-site: www.elektral.com.tr

When you open the boxes:• Main Control & Display Unit

• Back Fixing Unit

• Left Side Panel

• Right Side Panel

2

Page 4: ELEKTRAL A.S

ELEKTRAL A.S.

ASSEMBLING & MOUNTING ThruScan

You need 15 minutes for assembling!...

Get User’s Manual

PLS. Download from our web-site: www.elektral.com.tr

3

4Assembling Back Fixing Unit

Other side

Page 5: ELEKTRAL A.S

ELEKTRAL A.S.

ASSEMBLING & MOUNTING ThruScan

You need 15 minutes for assembling!...

Get User’s Manual

PLS. Download from our web-site: www.elektral.com.tr

5

Screw up the rear cover of the Main Control & Display Unit.

Page 6: ELEKTRAL A.S

ELEKTRAL A.S.

ASSEMBLING & MOUNTING ThruScan

You need 15 minutes for assembling!...

Get User’s Manual

PLS. Download from our web-site: www.elektral.com.tr

6

7

For the sockets:

ThruScan is designed to prevent false connector/socket connection.

Left Panel – female D-Sub 25

Mains Socket - SRC- D-Sub 9

Right Panel – male D-Sub 25

Page 7: ELEKTRAL A.S

ELEKTRAL A.S.

ASSEMBLING & MOUNTING ThruScan

You need 15 minutes for assembling!...

Get User’s Manual

PLS. Download from our web-site: www.elektral.com.tr

8 9

Screw down the Main Control & Display Unit.

Fix strongly to the side panels.

Page 8: ELEKTRAL A.S

ELEKTRAL A.S.

ASSEMBLING & MOUNTING ThruScan

You need 15 minutes for assembling!...

Get User’s Manual

PLS. Download from our web-site: www.elektral.com.tr

1011

Fasten the black blind taps

Lift up your ThruScan

Page 9: ELEKTRAL A.S

ELEKTRAL A.S.

ASSEMBLING & MOUNTING ThruScan

You need 15 minutes for assembling!...

Get User’s Manual

PLS. Download from our web-site: www.elektral.com.tr

12

Plug in the connectors.

Page 10: ELEKTRAL A.S

ELEKTRAL A.S.

ASSEMBLING & MOUNTING ThruScan

You need 15 minutes for assembling!...

Get User’s Manual

PLS. Download from our web-site: www.elektral.com.tr

13

14

Left Side Panel Connectors

Right Side Panel Connector Mains Connector (from left

side panel)

Impossible to make mistake…

Page 11: ELEKTRAL A.S

ELEKTRAL A.S.

ASSEMBLING & MOUNTING ThruScan

You need 15 minutes for assembling!...

Get User’s Manual

PLS. Download from our web-site: www.elektral.com.tr

15

Close the rear cover of Main Display & Control Unit.

Page 12: ELEKTRAL A.S

ELEKTRAL A.S.

ASSEMBLING & MOUNTING ThruScan

Adjust the distance between side panels to 76 cms.

You need 15 minutes for assembling!...

Get User’s Manual

PLS. Download from our web-site: www.elektral.com.tr

16

Page 13: ELEKTRAL A.S

ELEKTRAL A.S.

ASSEMBLING & MOUNTING ThruScan

You need 15 minutes for assembling!...

Get User’s Manual

PLS. Download from our web-site: www.elektral.com.tr

17 18

Mark the positions of side panel holders.

Page 14: ELEKTRAL A.S

ELEKTRAL A.S.

ASSEMBLING & MOUNTING ThruScan

You need 15 minutes for assembling!...

Get User’s Manual

PLS. Download from our web-site: www.elektral.com.tr

19 20

21 22

Drill & Fix the side panel holders to the ground – stable conditions.

Page 15: ELEKTRAL A.S

ELEKTRAL A.S.

ASSEMBLING & MOUNTING ThruScan

You need 15 minutes for assembling!...

Get User’s Manual

PLS. Download from our web-site: www.elektral.com.tr

23

24

25

Put your ThruScan into the side panel holders inside and screw the bolts.

Page 16: ELEKTRAL A.S

ELEKTRAL A.S.

CONTROL PANEL OF ThruScan Metal Detectors

LCD DISPLAY 4*20

OFF BUTTON ON BUTTON BATTERY INDICATOR

PACING LIGHT

INDICATOR

LED VU

DISPLAY

ALARM LOCATORRUN BUTTON

SEL UP DOWN

TOUCH PADS

Page 17: ELEKTRAL A.S

ELEKTRAL A.S.

MULTI POINT INDICATOR LIGHTS

ENTRANCE- Traffic Lights

Led illuminated Warning Displays on Zones

Page 18: ELEKTRAL A.S

ELEKTRAL A.S.

RELAY CONTACT OUTPUTS

RELAY CONTACT OUTPUTS

SYNC & REMOTE CONTROL OUTPUTS

Provides to control CCTV Cameras, Turnstiles, Gates…etc.

For tandem operation or

SRC- Scada Remote Control

Page 19: ELEKTRAL A.S

ELEKTRAL A.S.

PROGRAMMING & SETUP

Normal Operating Screen(When you swich on – the screen)

IN OUT01978 00027

SECURITY LEVEL 03

ENTER PASSWORD[0---]

To enter the program menu

Press

SECURITY LEVEL

LEVEL 02

If the correct password is entered display will

change to:

SECURITY LEVELPASSWORD ERROR

If the password is incorrect:

Page 20: ELEKTRAL A.S

ELEKTRAL A.S.

SECURITY LEVEL & SENSITIVITY LEVEL ADJUSTMENTS

SECURITY LEVEL

LEVEL 02ThruScan s9 has 10 seperate SECURITY LEVELS

ThruScan sX has 20 seperate SECURITY LEVELS

SECURITY LEVEL SENSITIVITY ADJUSTMENT

Security Level (NC) NILECJ – Level 2 (factory fixed)

Security Level 1 010

Security Level 2 020

Security Level 3 030

Security Level 4 050

Security Level 5 100

Security Level 6 140

Security Level 7 180

Security Level 8 220

Security Level 9 230

ThruScan s9

It is possible to adjust a total of 246 sensitivity levels from security level 000 (highest sensitivity) to 245 (lowest sensitivity)

SECURITY LEVEL

LEVEL [02]=20

Page 21: ELEKTRAL A.S

ELEKTRAL A.S.

SECURITY LEVEL & SENSITIVITY LEVEL ADJUSTMENTS

SECURITY LEVEL

LEVEL 02

ThruScan sXSECURITY LEVEL SENSITIVITY ADJUSTMENT

Security Level (NC) NILECJ – Level 2(factory fixed)

Security Level 1 010

Security Level 2 020Security Level 3 030Security Level 4 040Security Level 5 050Security Level 6 060Security Level 7 070Security Level 8 080Security Level 9 090Security Level 10 100Security Level 11 110

Security Level 12Security Level 13Security Level 14Security Level 15Security Level 16Security Level 17Security Level 18Security Level AD

120140160180200220240030 – Auto Designation/AD

SECURITY LEVEL

LEVEL [02]=20

SECURITY LEVEL

LEVEL [15]=180

Page 22: ELEKTRAL A.S

ELEKTRAL A.S.

SECURITY LEVEL

LEVEL [15]=180

You can make fine tunning here: 185Between 000(highest sebsitivity) – 245(lowest sensitivity)

IN OUT01978 00027

SECURITY LEVEL 03

ENTER PASSWORD[0---]

SECURITY LEVEL

LEVEL 02

SECURITY LEVEL

LEVEL [02]

SECURITY LEVEL

LEVEL [15]

Page 23: ELEKTRAL A.S

ELEKTRAL A.S.

SECURITY LEVEL

LEVEL [15]=180

SECURITY LEVEL

LEVEL [15]=181

SECURITY LEVEL

LEVEL [15]=185

Normal Operating Mode

Other Menus

Page 24: ELEKTRAL A.S

ELEKTRAL A.S.

SECURITY LEVEL & SENSITIVITY LEVEL,ZONE ADJUSTMENTS for ThruScan sX

The sensitivity levels of zones can be adjusted separately.

The sensitivity level of zone 2 in which there would more likely be keys, cell phones, belts etc. can be decreased while the other zones’ can be increased.

IN OUT01978 00027

SECURITY LEVEL 03

* 5 SECURITY LEVEL

LEVEL [02]=20

* 1SECURITY LEVEL

INDIVIDUAL ZONE SENSLEVEL 02

SECURITY LEVELINDIVIDUAL ZONE SENS

LEVEL [02]

SECURITY LEVELINDIVIDUAL ZONE SENS

LEVEL [02]ZONE=[01]

ZONE=2 ZONE=3

ZONE [01]=20

Normal Operating Mode

Other Menus

Page 25: ELEKTRAL A.S

ELEKTRAL A.S.

AUTO DESIGNATION AND AUTOMATIC SENSITIVITY ASSIGN for ThruScan sX

This menu is to help the user to decide and to assign the required sensitivity level very rapidly.

IN OUT01978 00027

SECURITY LEVEL 03

* 5 SECURITY LEVEL

LEVEL [02]=20* 2

USED FOR AUTODESIGNATE OF

SECURITY LEVEL TOCONTINUE PRESS SEL

AUTO DESIGNATE MODE

WHEN TRAFFIC LED ISGREEN, ENTER

METAL OBJECT THENPRESS SEL 3/1

WHEN TRAFFIC LED ISGREEN, ENTER

METAL OBJECT THENPRESS SEL 3/2

WHEN TRAFFIC LED ISGREEN, ENTER

METAL OBJECT THENPRESS SEL 3/3

DESIGNATE-DETECTMODALL ZONES 00 ZONE 01

[00]

01

00

Page 26: ELEKTRAL A.S

ELEKTRAL A.S.

AUTO DESIGNATE MODETO DESIGNATE PRESS SEL

LEVEL [AD]=53

DESIGNATE-DETECTMODALL ZONES 00 ZONE 01

[53]

01

AUTO DESIGNATE MODE IN OUT01978 00027

SECURITY LEVEL 03

AUTO DESIGNATE MODETO DESIGNATE PRESS SEL

ZONE [01]

SELECT THE ZONE

AUTO DESIGNATE MODETO DESIGNATE PRESS SEL

ZONE [01]=53

AUTO DESIGNATION MODE - continue

Page 27: ELEKTRAL A.S

ELEKTRAL A.S.

ALARM VOLUME ADJUSTMENT

IN OUT01978 00027

SECURITY LEVEL 03

* 5 SECURITY LEVEL

LEVEL [02]=20* 3 ALARM VOLUME

0<=>10

ALARM VOLUME0<=>10

VOLUME=05

ALARM VOLUME0<=>10

VOLUME=10

ThruScan s9-sX has 10 separate alarm volume levels, 1 quietest – 10 loudest – 00 Mute

If you want different tones, pls mention with your order. It has 10 different tones in the menu.

Page 28: ELEKTRAL A.S

ELEKTRAL A.S.

ALARM COUNTER

IN OUT01978 00027

SECURITY LEVEL 03

* 5 SECURITY LEVEL

LEVEL [02]=20* 4 ALARM COUNTER

00012

ALARM COUNTER00012

RESET Y <=> N N

ALARM COUNTER00000

ALARM COUNTER00012

RESET Y <=> N Y

NORMALOPERATINGMODE

MENU

Page 29: ELEKTRAL A.S

ELEKTRAL A.S.

IN – OUT COUNTER (TRAFFIC COUNT)

IN OUT01978 00027

SECURITY LEVEL 03

* 5 SECURITY LEVEL

LEVEL [02]=20* 5 IN>-COUNTER-<OUT

99999………………….…01977

NORMALOPERATINGMODE

MENU

IN>-COUNTER-<OUT99999………………….…01977

ACTIVE =0000 – Do not reset01 – Reset In Count02 – Reset Out Count03 – Reset Both Counters

Page 30: ELEKTRAL A.S

ELEKTRAL A.S.

FACTORY SETTINGS

IN OUT01978 00027

SECURITY LEVEL 03

* 5 SECURITY LEVEL

LEVEL [02]=20* 6 FACTORY SETTINGS

Y<==>N

NORMALOPERATINGMODE

MENU

Y – FACTORY RESETN – DO NOT RESET

FACTORY SETTINGSY<==>N

ACTIVE =N

ThruScan s9-sX can be returned to factory setting by this menu.

Page 31: ELEKTRAL A.S

ELEKTRAL A.S.

LANGUAGE SELECTION

IN OUT01978 00027

SECURITY LEVEL 03

* 5 SECURITY LEVEL

LEVEL [02]=20* 7 LANGUAGE

ENGLISH

NORMALOPERATINGMODE

MENU

ENGLISHDEUTSCHTURKCEESPANOL

ThruScan s9-sX can be operated in 4 languages- EN-DE-SPA-TR

LANGUAGEENGLISH

<===================>

Page 32: ELEKTRAL A.S

ELEKTRAL A.S.

COUNTER VISIBILITY

IN OUT01978 00027

SECURITY LEVEL 03

* 5 SECURITY LEVEL

LEVEL [02]=20* 8 COUNTER VISIBILITY

Y<==>N

NORMALOPERATINGMODE

MENU

N – DISPLAY OFFY – DISPLAY ON

ThruScan s9-sx’ Normal Operating Mode-Menu Displaycan be inhibited.

COUNTER VISIBILITYY<==>N

ACTIVE =Y

IN OUT ***** *****

SECURITY LEVEL 03

Page 33: ELEKTRAL A.S

ELEKTRAL A.S.

ENVIRONMENT NOISE LEVEL

IN OUT01978 00027

SECURITY LEVEL 03

* 5 SECURITY LEVEL

LEVEL [02]=20* 9 ENVIRONMENTAL

NOISE LEVEL

NORMALOPERATINGMODE

MENU

This menu is prepared to measure the electromagnetic noise level in the environment in which the ThruScan was placed and help the user with the sensitivity level assignment.

ENVIRONMENTALNOISE LEVELNOISE = 003

Page 34: ELEKTRAL A.S

ELEKTRAL A.S.

NEW PASSWORD

IN OUT01978 00027

SECURITY LEVEL 03

* 5 SECURITY LEVEL

LEVEL [02]=20* 10 NEW PASSWORD

[ ]

NORMALOPERATINGMODE

MENU

You can change your 4 digit pin-code as follows: Let’s make password 1978

NEW PASSWORD[ 0 * * * ]

123……….89

NEW PASSWORD[ 1 * * * ]

123……….89

NEW PASSWORD[ 1 9 7 8 ]