Shenzhen Anbotek Compliance Laboratory Limited Page 1 of 27 Report No. R011501450I Shenzhen Anbotek Compliance Laboratory Limited Tel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com EMC TEST REPORT for AOK LED LIGHT COMPANY LIMITED LED Street Light Model No. : AOK-30WiL, AOK-40WiL, AOK-60WiL, AOK-80WiL, AOK-90WiL, AOK-120WiL, AOK-160WiL, AOK-150WiL, AOK-200WiL, AOK-180WiL, AOK-240WiL Report Number : R011501450I Date of Test : Jan. 19~29, 2015 Date of Report : Jan. 30, 2015 Applicant : AOK LED LIGHT COMPANY LIMITED Building 1 St George's Science and Technology Industrial Park, Outer Ring Road Bao'an, Shenzhen, Guangdong, China Prepared By : Shenzhen Anbotek Compliance Laboratory Limited Address : 1/F., Building 1, SEC Industrial Park, No.0409 Qianhai Road, Nanshan District, Shenzhen, Guangdong, China Tel: (86) 755-26066544 Fax: (86) 755-26014772

Upload: others

Post on 04-Apr-2020

13 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: EMC TEST REPORT for AOK LED LIGHT COMPANY LIMITED LED ...5qrorwxhiojqjij.ldycdn.com/...EMC-Report-Of-AOK-Street-Light-iL-Serie… · EMC TEST REPORT for AOK LED LIGHT COMPANY LIMITED

Shenzhen Anbotek Compliance Laboratory LimitedPage 1 of 27 Report No. R011501450I

Shenzhen Anbotek Compliance Laboratory LimitedTel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com

EMC TEST REPORTfor

AOK LED LIGHT COMPANY LIMITED

LED Street LightModel No. : AOK-30WiL, AOK-40WiL, AOK-60WiL, AOK-80WiL, AOK-90WiL,

AOK-120WiL, AOK-160WiL, AOK-150WiL, AOK-200WiL, AOK-180WiL,AOK-240WiL

Report Number : R011501450IDate of Test : Jan. 19~29, 2015Date of Report : Jan. 30, 2015

Applicant : AOK LED LIGHT COMPANY LIMITEDBuilding 1 St George's Science and Technology Industrial Park,Outer Ring Road Bao'an, Shenzhen, Guangdong, China

Prepared By : Shenzhen Anbotek Compliance Laboratory LimitedAddress : 1/F., Building 1, SEC Industrial Park, No.0409 Qianhai Road,

Nanshan District, Shenzhen, Guangdong, ChinaTel: (86) 755-26066544Fax: (86) 755-26014772

Page 2: EMC TEST REPORT for AOK LED LIGHT COMPANY LIMITED LED ...5qrorwxhiojqjij.ldycdn.com/...EMC-Report-Of-AOK-Street-Light-iL-Serie… · EMC TEST REPORT for AOK LED LIGHT COMPANY LIMITED

Shenzhen Anbotek Compliance Laboratory LimitedPage 2 of 27 Report No. R011501450I

Shenzhen Anbotek Compliance Laboratory LimitedTel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com

TABLE OF CONTENTS

Description Page

Test Report Verification

1. GENERAL INFORMATION...........................................................................................................41.1. Description of Device (EUT)......................................................................................................................41.2. Description of Test Facility........................................................................................................................ 51.3. Measurement Uncertainty...........................................................................................................................51.4. Test Summary.............................................................................................................................................51.5. Model list....................................................................................................................................................6

2. CONDUCTED EMISSION TEST....................................................................................................72.1. Block Diagram of Test Setup..................................................................................................................... 72.2. Measuring Standard....................................................................................................................................72.3. Power Line Conducted Emission Limits.................................................................................................... 72.4. EUT Configuration on Measurement......................................................................................................... 72.5. Operating Condition of EUT...................................................................................................................... 72.6. Test Procedure............................................................................................................................................ 82.7. Test Equipment...........................................................................................................................................82.8. Measuring Results...................................................................................................................................... 8

3. RADIATED EMISSION TEST......................................................................................................113.1. Block Diagram of Test..............................................................................................................................113.2. Measuring Standard.................................................................................................................................. 113.3. Radiated Emission Limits.........................................................................................................................113.4. EUT Configuration on Test...................................................................................................................... 123.5. Operating Condition of EUT.................................................................................................................... 123.6. Test Procedure.......................................................................................................................................... 123.7. Test Equipment.........................................................................................................................................123.8. Measuring Results.................................................................................................................................... 12

4. MAGNETIC RADIATED EMISSION TEST...............................................................................154.1. Block Diagram of Test Setup................................................................................................................... 154.2. Magnetic Field Emission Measurement Standard and Limits..................................................................154.3. EUT Configuration on Measurement....................................................................................................... 154.4. Operating Condition of EUT.................................................................................................................... 154.5. Test Procedure.......................................................................................................................................... 164.6. Test Equipment.........................................................................................................................................164.7. Measuring Results.................................................................................................................................... 16

5. PHOTOGRAPH...............................................................................................................................205.1. Photo of Conducted Emission Test...........................................................................................................205.2. Photo of Radiation Emission Test............................................................................................................ 205.3. Photo of Magnetic Radiated Emission Test..............................................................................................21

APPENDIX I (Photos of EUT) (5 pages)

Page 3: EMC TEST REPORT for AOK LED LIGHT COMPANY LIMITED LED ...5qrorwxhiojqjij.ldycdn.com/...EMC-Report-Of-AOK-Street-Light-iL-Serie… · EMC TEST REPORT for AOK LED LIGHT COMPANY LIMITED
Page 4: EMC TEST REPORT for AOK LED LIGHT COMPANY LIMITED LED ...5qrorwxhiojqjij.ldycdn.com/...EMC-Report-Of-AOK-Street-Light-iL-Serie… · EMC TEST REPORT for AOK LED LIGHT COMPANY LIMITED

Shenzhen Anbotek Compliance Laboratory LimitedPage 4 of 27 Report No. R011501450I

Shenzhen Anbotek Compliance Laboratory LimitedTel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com

1. GENERAL INFORMATION

1.1. Description of Device (EUT)EUT : LED Street Light

Model Number : AOK-30WiL, AOK-40WiL, AOK-60WiL, AOK-80WiL,AOK-90WiL, AOK-120WiL, AOK-160WiL, AOK-150WiL,AOK-200WiL, AOK-180WiL, AOK-240WiL(Note: All samples are the same except the model number &output of appliances, so we prepare “AOK-240WiL” for EMCtest only.)

Test Power Supply : AC 240, 50Hz

Applicant : AOK LED LIGHT COMPANY LIMITEDBuilding 1 St George's Science and Technology Industrial Park,Outer Ring Road Bao'an, Shenzhen, Guangdong, China

Manufacturer : AOK LED LIGHT COMPANY LIMITEDAddress : Building 1 St George's Science and Technology Industrial Park,

Outer Ring Road Bao'an, Shenzhen, Guangdong, China

Factory : AOK LED LIGHT COMPANY LIMITEDAddress : Building 1 St George's Science and Technology Industrial Park,

Outer Ring Road Bao'an, Shenzhen, Guangdong, China

Date of receipt : Jan. 19, 2015

Date of Test : Jan. 19~29, 2015

Page 5: EMC TEST REPORT for AOK LED LIGHT COMPANY LIMITED LED ...5qrorwxhiojqjij.ldycdn.com/...EMC-Report-Of-AOK-Street-Light-iL-Serie… · EMC TEST REPORT for AOK LED LIGHT COMPANY LIMITED

Shenzhen Anbotek Compliance Laboratory LimitedPage 5 of 27 Report No. R011501450I

Shenzhen Anbotek Compliance Laboratory LimitedTel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com

1.2.Description of Test FacilityThe test facility is recognized, certified, or accredited by the following organizations:

CNAS - LAB Code: L3503Shenzhen Anbotek Compliance Laboratory Limited., Laboratory has been assessed and incompliance with CNAS/CL01: 2006 accreditation criteria for testing laboratories(identical to ISO/IEC 17025: 2005 General Requirements) for the Competence of TestingLaboratories.

FCC-Registration No.: 752021Shenzhen Anbotek Compliance Laboratory Limited, EMC Laboratory has beenregistered and fully described in a report filed with the (FCC) FederalCommunications Commission. The acceptance letter from the FCC is maintained inour files. Registration 752021, July 10, 2013

IC-Registration No.: 8058A-1Shenzhen Anbotek Compliance Laboratory Limited., EMC Laboratory has beenregistered and fully described in a report filed with the (IC) Industry Canada. Theacceptance letter from the IC is maintained in our files. Registration 8058A-1, Feb.22, 2013

Test LocationAll Emissions tests were performed:Shenzhen Anbotek Compliance Laboratory Limited. at 1/F., Building 1, SECIndustrial Park, No.0409 Qianhai Road, Nanshan District, Shenzhen, Guangdong,China

1.3. Measurement UncertaintyRadiation Uncertainty : Ur = 4.1dB (Horizontal)

Ur = 4.3dB (vertical)

Conduction Uncertainty : Uc =3.4dB

1.4. Test SummaryTests Carried Out Under AS/NZS CISPR 15: 2011

Standard Test Items Status

AS/NZS CISPR 15: 2011 Power Line Conducted Emission Test(9kHz To 30MHz)

AS/NZS CISPR 15: 2011 Radiated Emission Test(30MHz To 300MHz)

AS/NZS CISPR 15: 2011 Magnetic Radiated emission Test(9KHz To 30MHz)

√ Indicates that the test is applicablex Indicates that the test is not applicable

Page 6: EMC TEST REPORT for AOK LED LIGHT COMPANY LIMITED LED ...5qrorwxhiojqjij.ldycdn.com/...EMC-Report-Of-AOK-Street-Light-iL-Serie… · EMC TEST REPORT for AOK LED LIGHT COMPANY LIMITED

Shenzhen Anbotek Compliance Laboratory LimitedPage 6 of 27 Report No. R011501450I

Shenzhen Anbotek Compliance Laboratory LimitedTel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com

1.5. Model list

Model Power Driver LEDquantity

Modulequantity

Dimension(mm)

AOK-30WiL40W HLG-60H-48A 14 1 Module 495x300x107

AOK-40WiL

AOK-60WiL80W HLG-100H-48A 28 2 Module 576x300x107

AOK-80WiL

AOK-90WiL120W HLG-150H-48A 42 3 Module 657x300x107

AOK-120WiL

AOK-160WiL 160W HLG-185H-48A 56 4 Module 738x300x107

AOK-150WiL200W HLG-240H-48A 70 5 Module 819x300x107

AOK-200WiL

AOK-180WiL240W HLG-240H-48A 84 6 Module 900x300x107

AOK-240WiL

Page 7: EMC TEST REPORT for AOK LED LIGHT COMPANY LIMITED LED ...5qrorwxhiojqjij.ldycdn.com/...EMC-Report-Of-AOK-Street-Light-iL-Serie… · EMC TEST REPORT for AOK LED LIGHT COMPANY LIMITED

Shenzhen Anbotek Compliance Laboratory LimitedPage 7 of 27 Report No. R011501450I

Shenzhen Anbotek Compliance Laboratory LimitedTel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com

2. CONDUCTED EMISSION TEST

2.1. Block Diagram of Test Setup2.1.1. Block diagram of connection between the EUT and simulators

2.2. Measuring StandardAS/NZS CISPR 15: 2011

2.3. Power Line Conducted Emission Limits

Frequency At mains terminals (dBμV)Quasi-peak Level Average Level

9KHz ~ 50KHz 110 --50KHz ~ 150KHz 90 ~ 80* --

150KHz ~ 0.5MHz 66 ~ 56* 56 ~ 46*0.5MHz ~ 5.0MHz 56 465.0MHz ~ 30MHz 60 50

1. At the transition frequency the lower limit applies.2. * decreasing linearly with logarithm of the frequency.

2.4. EUT Configuration on MeasurementThe following equipments are installed on Conducted Emission Measurement to meetAS/NZS CISPR 15: 2011 requirements and operating in a manner which tends tomaximize its emission characteristics in a normal application.

2.5. Operating Condition of EUT

2.5.1. Setup the EUT as shown on Section 2.1.

2.5.2. Turn on the power of all equipments.

2.5.3. Let the EUT work in measuring mode (On) and measure it.

L.I.S.N

Test Receiver

AC mainsEUT

Page 8: EMC TEST REPORT for AOK LED LIGHT COMPANY LIMITED LED ...5qrorwxhiojqjij.ldycdn.com/...EMC-Report-Of-AOK-Street-Light-iL-Serie… · EMC TEST REPORT for AOK LED LIGHT COMPANY LIMITED

Shenzhen Anbotek Compliance Laboratory LimitedPage 8 of 27 Report No. R011501450I

Shenzhen Anbotek Compliance Laboratory LimitedTel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com

2.6. Test ProcedureThe EUT is put on the plane 0.8m high above the ground by insulating support andconnected to the AC mains through Line Impedance Stability Network (L.I.S.N). Thisprovided a 50ohm coupling impedance for the tested equipments. Both sides of ACline are investigated to find out the maximum conducted emission according to theAS/NZS CISPR 15 regulations during conducted emission measurement.

The bandwidth of the field strength meter (R&S Test Receiver ESCI) is set at 9kHz in150kHz~30MHz.

The frequency range from 9kHz to 30MHz is investigated for AC mains.

The test results are listed in Section 2.8.

2.7. Test EquipmentThe following test equipments are used during the power line conducted measurement:

Item Equipment Manufacturer Model No. Serial No. Last Cal. Cal. Interval1. Two-Line

V-network Rohde & Schwarz ENV216 100055 Apr. 22, 2014 1 Year

2. EMI Test Receiver Rohde & Schwarz ESCI 100627 Apr. 22, 2014 1 Year3. RF Switching Unit Compliance

Direction RSU-M2 38303 Apr. 22, 2014 1 Year

2.8. Measuring ResultsPASS.

The frequency range 9kHz to 30MHz is investigated.

The test curves are shown in the following pages.

Page 9: EMC TEST REPORT for AOK LED LIGHT COMPANY LIMITED LED ...5qrorwxhiojqjij.ldycdn.com/...EMC-Report-Of-AOK-Street-Light-iL-Serie… · EMC TEST REPORT for AOK LED LIGHT COMPANY LIMITED

Shenzhen Anbotek Compliance Laboratory LimitedPage 9 of 27 Report No. R011501450I

Shenzhen Anbotek Compliance Laboratory LimitedTel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com

CONDUCTED EMISSION TEST DATA

Test Site: 1# Shielded RoomOperating Condition: OnTest Specification: AC 240, 50HzComment: L

Temp.:22.2℃ Hum:60%

Page 10: EMC TEST REPORT for AOK LED LIGHT COMPANY LIMITED LED ...5qrorwxhiojqjij.ldycdn.com/...EMC-Report-Of-AOK-Street-Light-iL-Serie… · EMC TEST REPORT for AOK LED LIGHT COMPANY LIMITED

Shenzhen Anbotek Compliance Laboratory LimitedPage 10 of 27 Report No. R011501450I

Shenzhen Anbotek Compliance Laboratory LimitedTel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com

CONDUCTED EMISSION TEST DATA

Test Site: 1# Shielded RoomOperating Condition: OnTest Specification: AC 240, 50HzComment: N

Temp.:22.2℃ Hum:60%

Page 11: EMC TEST REPORT for AOK LED LIGHT COMPANY LIMITED LED ...5qrorwxhiojqjij.ldycdn.com/...EMC-Report-Of-AOK-Street-Light-iL-Serie… · EMC TEST REPORT for AOK LED LIGHT COMPANY LIMITED

Shenzhen Anbotek Compliance Laboratory LimitedPage 11 of 27 Report No. R011501450I

Shenzhen Anbotek Compliance Laboratory LimitedTel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com

3. RADIATED EMISSION TEST

3.1. Block Diagram of Test

3.1.1. Block diagram of connection between the EUT and simulators

AC Mains

3.1.2. Block diagram of test setup (In chamber)

3.2. Measuring StandardAS/NZS CISPR 15: 2011

3.3. Radiated Emission Limits3.3.1. AS/NZS CISPR 15

Radiated Emission LimitsAll emanations from a CISPR 15 device or system, including any networkof conductors and apparatus connected thereto, shall not exceed the levelof field strengths specified below:

FREQUENCY DISTANCE FIELD STRENGTHS LIMIT(MHz) (Meters) (dBμV/m)

30 ~ 230 3 40230 ~ 300 3 47

Note: (1) The smaller limit shall apply at the combination point between

0.8 METER

ANTENNA ELEVATION VARIES FROM 1 TO 4 METERS

3 METERSEUT System

GROUND PLANE

EUT

Page 12: EMC TEST REPORT for AOK LED LIGHT COMPANY LIMITED LED ...5qrorwxhiojqjij.ldycdn.com/...EMC-Report-Of-AOK-Street-Light-iL-Serie… · EMC TEST REPORT for AOK LED LIGHT COMPANY LIMITED

Shenzhen Anbotek Compliance Laboratory LimitedPage 12 of 27 Report No. R011501450I

Shenzhen Anbotek Compliance Laboratory LimitedTel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com

two frequency bands.(2) Distance refers to the distance in meters between the measuring

instrument antenna and the closed point of any part of the EUT.

3.4. EUT Configuration on TestThe AS/NZS CISPR 15: 2011 regulations test method must be used to find themaximum emission during radiated emission measurement.

3.5. Operating Condition of EUT

3.5.1. Turn on the power.

3.5.2. Let the EUT work in test mode (On) and measure it.

3.6. Test ProcedureThe EUT is placed on a turn table which is 0.8 meter high above the ground. The turntable can rotate 360 degrees to determine the position of the maximum emission level.The EUT is set 3 meters away from the receiving antenna which is mounted on aantenna tower. The antenna can be moved up and down from 1 to 4 meters to find outthe maximum emission level. Bilog antenna (calibrated by Dipole Antenna) is used asa receiving antenna. Both horizontal and vertical polarization of the antenna are set ontest.

The bandwidth of the Receiver (ESCI) is set at 120kHz.

The EUT is tested in 9*6*6 Chamber.

The test results are listed in Section 3.8.

3.7. Test EquipmentThe following test equipments are used during radiated emission measurement:

Item Equipment Manufacturer Model No. Serial No. Last Cal. Cal. Interval1. EMI Test Receiver Rohde & Schwarz ESPI 101604 Apr. 22, 2014 1 Year2. Bilog Broadband

Antenna Schwarzbeck VULB9163 VULB9163-289 May 14, 2013 3 Year

3. Pre-amplifier SONOMA 310N 186860 Aug. 08, 2014 1 Year

3.8. Measuring ResultsPASS.

The frequency range from 30MHz to 300MHz is investigated.

Test data see the following pages.

Page 13: EMC TEST REPORT for AOK LED LIGHT COMPANY LIMITED LED ...5qrorwxhiojqjij.ldycdn.com/...EMC-Report-Of-AOK-Street-Light-iL-Serie… · EMC TEST REPORT for AOK LED LIGHT COMPANY LIMITED

Shenzhen Anbotek Compliance Laboratory LimitedPage 13 of 27 Report No. R011501450I

Shenzhen Anbotek Compliance Laboratory LimitedTel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com

Job No.: AT011501450I Polarization: Horizontal

Standard: (RE)AS/NZS CISPR 15_3m Power Source: AC 240, 50Hz

Test item: Radiation Test Temp.(℃)/Hum.(%RH): 24.3(℃)/55%RH

Note: On Distance: 3m

Page 14: EMC TEST REPORT for AOK LED LIGHT COMPANY LIMITED LED ...5qrorwxhiojqjij.ldycdn.com/...EMC-Report-Of-AOK-Street-Light-iL-Serie… · EMC TEST REPORT for AOK LED LIGHT COMPANY LIMITED

Shenzhen Anbotek Compliance Laboratory LimitedPage 14 of 27 Report No. R011501450I

Shenzhen Anbotek Compliance Laboratory LimitedTel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com

Job No.: AT011501450I Polarization: Vertical

Standard: (RE)AS/NZS CISPR 15_3m Power Source: AC 240, 50Hz

Test item: Radiation Test Temp.(℃)/Hum.(%RH): 24.3(℃)/55%RH

Note: On Distance: 3m

Page 15: EMC TEST REPORT for AOK LED LIGHT COMPANY LIMITED LED ...5qrorwxhiojqjij.ldycdn.com/...EMC-Report-Of-AOK-Street-Light-iL-Serie… · EMC TEST REPORT for AOK LED LIGHT COMPANY LIMITED

Shenzhen Anbotek Compliance Laboratory LimitedPage 15 of 27 Report No. R011501450I

Shenzhen Anbotek Compliance Laboratory LimitedTel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com

4. MAGNETIC RADIATED EMISSION TEST

4.1. Block Diagram of Test Setup

AC Mains

4.2. Magnetic Field Emission Measurement Standard and Limits

4.2.1. Measuring Standard

AS/NZS CISPR 15: 2011

4.2.2. Measuring Limits

Frequency Limits for loop diameter (dBμA)2m

9KHz ~ 70KHz 8870KHz ~ 150KHz 88 ~ 58*

150KHz ~ 3MHz 58 ~ 22*3MHz ~ 30MHz 22

1. At the transition frequency the lower limit applies.2. * decreasing linearly with logarithm of the frequency.

4.3. EUT Configuration on MeasurementThe following equipments are installed on Magnetic Radiated emission Measurementto meet AS/NZS CISPR 15 requirements and operating in a manner which tends tomaximize its emission characteristics in a normal application.

4.4. Operating Condition of EUT

4.4.1. Setup the EUT as shown in Section 4.1.

4.4.2. Turn on the power of all equipments.

4.4.3. Let the EUT work in test mode (On) and measure it.

EUT

2m Loop Antenna

Test Receiver

Page 16: EMC TEST REPORT for AOK LED LIGHT COMPANY LIMITED LED ...5qrorwxhiojqjij.ldycdn.com/...EMC-Report-Of-AOK-Street-Light-iL-Serie… · EMC TEST REPORT for AOK LED LIGHT COMPANY LIMITED

Shenzhen Anbotek Compliance Laboratory LimitedPage 16 of 27 Report No. R011501450I

Shenzhen Anbotek Compliance Laboratory LimitedTel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com

4.5. Test ProcedureThe EUT is placed on a wood table in the center of a loop antenna. The induced currentin the loop antenna is measured by means of a current probe and the test receiver. Threefield components are checked by means of a coaxial switch.

The frequency range from 9KHz to 30MHz is investigated. The receiver is measuredwith the quasi-peak detector. For frequency band 9KHz to 150KHz, the bandwidth ofthe test receiver (ESCI) is set at 200Hz. For frequency band 150KHz to 30MHz, thebandwidth is set at 9KHz.

All the test results are listed in Section 4.7.

4.6. Test EquipmentThe following test equipments are used during the Magnetic Radiated emissionmeasurement:

Item Equipment Manufacturer Model No. Serial No. Last Cal. Cal.Interval

1. EMI Test Receiver Rohde & Schwarz ESCI 100627 Apr. 22, 2014 1 Year2. Triple-Loop

Antenna(2M) EVERFINE LLA-2 905003 Apr. 22, 2014 3 Year

3. RF Switching Unit Compliance Direction RSU-M2 38303 Apr. 22, 2014 1 Year

4.7. Measuring ResultsPASS.

The frequency range from 9KHz to 30MHz is investigated.

Test data see the following pages.

Page 17: EMC TEST REPORT for AOK LED LIGHT COMPANY LIMITED LED ...5qrorwxhiojqjij.ldycdn.com/...EMC-Report-Of-AOK-Street-Light-iL-Serie… · EMC TEST REPORT for AOK LED LIGHT COMPANY LIMITED

Shenzhen Anbotek Compliance Laboratory LimitedPage 17 of 27 Report No. R011501450I

Shenzhen Anbotek Compliance Laboratory LimitedTel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com

MAGNETIC RADIATED EMISSION TEST

Test Site: 1# Shielded RoomOperating Condition: OnTest Specification: AC 240, 50HzComment: X

Temp.:22.2℃ Hum:60%

Page 18: EMC TEST REPORT for AOK LED LIGHT COMPANY LIMITED LED ...5qrorwxhiojqjij.ldycdn.com/...EMC-Report-Of-AOK-Street-Light-iL-Serie… · EMC TEST REPORT for AOK LED LIGHT COMPANY LIMITED

Shenzhen Anbotek Compliance Laboratory LimitedPage 18 of 27 Report No. R011501450I

Shenzhen Anbotek Compliance Laboratory LimitedTel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com

MAGNETIC RADIATED EMISSION TEST

Test Site: 1# Shielded RoomOperating Condition: OnTest Specification: AC 240, 50HzComment: Y

Temp: 22.2℃ Hum: 59%

Page 19: EMC TEST REPORT for AOK LED LIGHT COMPANY LIMITED LED ...5qrorwxhiojqjij.ldycdn.com/...EMC-Report-Of-AOK-Street-Light-iL-Serie… · EMC TEST REPORT for AOK LED LIGHT COMPANY LIMITED

Shenzhen Anbotek Compliance Laboratory LimitedPage 19 of 27 Report No. R011501450I

Shenzhen Anbotek Compliance Laboratory LimitedTel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com

MAGNETIC RADIATED EMISSION TEST

Test Site: 1# Shielded RoomOperating Condition: OnTest Specification: AC 240, 50HzComment: Z

Temp: 22.2℃ Hum: 59%

Page 20: EMC TEST REPORT for AOK LED LIGHT COMPANY LIMITED LED ...5qrorwxhiojqjij.ldycdn.com/...EMC-Report-Of-AOK-Street-Light-iL-Serie… · EMC TEST REPORT for AOK LED LIGHT COMPANY LIMITED

Shenzhen Anbotek Compliance Laboratory LimitedPage 20 of 27 Report No. R011501450I

Shenzhen Anbotek Compliance Laboratory LimitedTel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com

5. PHOTOGRAPH

5.1. Photo of Conducted Emission Test

5.2. Photo of Radiation Emission Test

Page 21: EMC TEST REPORT for AOK LED LIGHT COMPANY LIMITED LED ...5qrorwxhiojqjij.ldycdn.com/...EMC-Report-Of-AOK-Street-Light-iL-Serie… · EMC TEST REPORT for AOK LED LIGHT COMPANY LIMITED

Shenzhen Anbotek Compliance Laboratory LimitedPage 21 of 27 Report No. R011501450I

Shenzhen Anbotek Compliance Laboratory LimitedTel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com

5.3. Photo of Magnetic Radiated Emission Test

Page 22: EMC TEST REPORT for AOK LED LIGHT COMPANY LIMITED LED ...5qrorwxhiojqjij.ldycdn.com/...EMC-Report-Of-AOK-Street-Light-iL-Serie… · EMC TEST REPORT for AOK LED LIGHT COMPANY LIMITED

Shenzhen Anbotek Compliance Laboratory LimitedPage 22 of 27 Report No. R011501450I

Shenzhen Anbotek Compliance Laboratory LimitedTel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com

APPENDIX I(Photos of EUT)

Page 23: EMC TEST REPORT for AOK LED LIGHT COMPANY LIMITED LED ...5qrorwxhiojqjij.ldycdn.com/...EMC-Report-Of-AOK-Street-Light-iL-Serie… · EMC TEST REPORT for AOK LED LIGHT COMPANY LIMITED

Shenzhen Anbotek Compliance Laboratory LimitedPage 23 of 27 Report No. R011501450I

Shenzhen Anbotek Compliance Laboratory LimitedTel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com

Figure 1The EUT-Front View

Figure 2The EUT-Back View

Page 24: EMC TEST REPORT for AOK LED LIGHT COMPANY LIMITED LED ...5qrorwxhiojqjij.ldycdn.com/...EMC-Report-Of-AOK-Street-Light-iL-Serie… · EMC TEST REPORT for AOK LED LIGHT COMPANY LIMITED

Shenzhen Anbotek Compliance Laboratory LimitedPage 24 of 27 Report No. R011501450I

Shenzhen Anbotek Compliance Laboratory LimitedTel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com

Figure 3The EUT-Inside View

Figure 4The EUT-Inside View

Page 25: EMC TEST REPORT for AOK LED LIGHT COMPANY LIMITED LED ...5qrorwxhiojqjij.ldycdn.com/...EMC-Report-Of-AOK-Street-Light-iL-Serie… · EMC TEST REPORT for AOK LED LIGHT COMPANY LIMITED

Shenzhen Anbotek Compliance Laboratory LimitedPage 25 of 27 Report No. R011501450I

Shenzhen Anbotek Compliance Laboratory LimitedTel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com

Figure 5The EUT-Inside View

Figure 6The EUT-Outside View(Model No.:AOK-200Wi)

Page 26: EMC TEST REPORT for AOK LED LIGHT COMPANY LIMITED LED ...5qrorwxhiojqjij.ldycdn.com/...EMC-Report-Of-AOK-Street-Light-iL-Serie… · EMC TEST REPORT for AOK LED LIGHT COMPANY LIMITED

Shenzhen Anbotek Compliance Laboratory LimitedPage 26 of 27 Report No. R011501450I

Shenzhen Anbotek Compliance Laboratory LimitedTel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com

Figure 7The EUT-Outside View(Model No.:AOK-160WiL)

Figure 8The EUT-Outside View(Model No.:AOK-120Wi)

Page 27: EMC TEST REPORT for AOK LED LIGHT COMPANY LIMITED LED ...5qrorwxhiojqjij.ldycdn.com/...EMC-Report-Of-AOK-Street-Light-iL-Serie… · EMC TEST REPORT for AOK LED LIGHT COMPANY LIMITED

Shenzhen Anbotek Compliance Laboratory LimitedPage 27 of 27 Report No. R011501450I

Shenzhen Anbotek Compliance Laboratory LimitedTel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com

Figure 9The EUT-Outside View(Model No.:AOK-80WiL)

Figure 10The EUT-Outside View(Model No.:AOK-40WiL)