• Computerized selection available.
• Standard ports NPT, optional SAE straight thread
or flange connections.
• Optional: built-in by-pass relief valve.
12V & 24V MOBILE AIR COOLED
OIL COOLERS
BULLETIN-LP, EOC, AOMF-2000
AOMF - LP - EOC SERIES
• Operating temperature of 400° F & pressure of 300PSI.
• Custom designs to fit your needs.
• Cools: Fluid power systems, lubrication systems,hydraulic presses,gear drives, torque convertors,
machine tools, etc...
EOC SERIES
LP Series
Visit our web site at www.aihti.comAOMF Series
Copyright © 2000 American Industrial Heat Transfer, Inc.
AOMF SERIES
Mobile hydraulic air/oil heat exchangers with
12 & 24 volt DC electric fan drive motors. Protec-
tive cabinet provides long service protection with
a clean appearance. Thermal capacity 85,000
BTU/HR based on 100°F ETD, with flow rates to
80gpm. Offered with NPT, SAE, and optional ser-
viceable relief ™ bypass valve. Operating tempera-
ture 400°F, operating pressure 300psi.
LP SERIES
Heavy-duty, Low Profile mobile hydraulic air/
oil heat exchangers with 12 & 24 volt DC electric
drive motors. Protective cabinet & core screen
provides a longer service life and a clean engi-
neered appearance. Thermal capacity to 80,000
BTU/HR based on 100°F ETD, with flow rates to
150gpm. Offered with NPT, SAE and optional ser-
viceable relief ™ bypass valve. Operating tempera-
ture 400°F, operating pressure 300psi.
EOC SERIES
High capacity mobile air-cooled heat ex-
changer with optional filter, and heavy duty off-road
12 & 24 Volt DC electric motors. Designed for en-
vironments where dust and debris are present.
Optional washable filter can be removed or in-
stalled in seconds for quick cleaning. Since the air
is drawn through the filter first, the internal com-
ponents remain clean and operational for optimal
performance. Thermal capacity to 228,000 BTU/
HR based on 100°F ETD, with flows to 180gpm.
Operating temperature 400°F, operating pressure
300psi.
2
INTRODUCTION
Copyright © 2000 American Industrial Heat Transfer, Inc.
SIZINGTo properly size a DC fan drive air-cooled oil cooler for mobile equipment, youshould first determine some basic parameters associated with the system.
HEAT LOADIn many instances the heat load must be determined by using a "total potential"method. This total potential or horse power method is the most common method,and is the simplest way to determine basic heat rejection requirements for mobilehydraulic systems. The total potential us equal to the maximum operating flowand pressure that are generated by the system under full load. To determine thetotal potential (HP) use the following formula.
HP = [ System Pressure (PSI) x System flow (GPM) ] / 1714
Example:HP = (3000 PSI x 40 GPM) / 1714 = 70 HP or the total input potential
To determine the system heat load in BTU / HR we must use a percentage (v) ofthe system potential HP. The factor (v) can be calculated by adding up the actualinefficiencies of a system; however, for most applications a (v) value of 25% - 30%can be used.
Example:70 HP x .25 = 17.5 HP heat
To convert the horsepower of heat into BTU/HR use the formula below:HP x 2542 = BTU/HR
Example:17.5 HP x 2545 = 44,538 BTU/HR
Applying into a return lineFor most open loop systems with a vane or gear type fixed delivery pumps. Tocalculate the Fs value required when applying the air/oil cooler into a return lineuse the formula below.
Fs =
T = Desired system oil temperature leaving the cooler °Ftambient = Ambient air temperature entering the cooler °FCv = Correction factor for oil viscosity. Example: ISO68 oil @ 150°F = 1.13 (seechart)
APPLYING INTO A CASE DRAIN LINEIn circumstances where the system is a closed loop or when return line flow is not
available, the case drain flow can be utilized to help cool the system However,in many instances, the case drain flow alone will not be enough to reject allof the heat generated by the system. Case drain lines should not be treatedas a normal return lines since the pressure drop allowable usually can varyfrom 12 - 10 PSI max. Check with your pump manufacturer for the appropriatepressure drop tolerance before applying any cooler. To size the system forcase flow or case flow plus any additional flushing loops, please use thefollowing method.
Formula
Tc exit = { T - [ Q / (case flow gpm x 210) ]}
Example
Tc exit = { 150 - [ 44,538 / (8 x 210) ]} = 123.5
Tc exit = The corrected temperature of the oil exiting the cooler.
Fs =
SELECTIONTo select a model, locate the flow rate (GPM) at the bottom of the flow vs Fsgraph of the series desired (AMOF, LP, EOC). Proceed upward until the GPMintersects with the calculated Fs. The curve closest above the intersectionpoint will meet these conditions.
Examples:
PRESSURE DROPDetermine the oil pressure drop from the curves as indicated. For viscositiesother than 50 ssu, multiply the actual indicated pressure drop (psi) for yourGPM by the value in the pressure differential curve for your viscosity value.
Examples: GPM = 40 GPM = 8
Indicated pressure drop 21PSI 1.5 PSICp correction factor forISO 68 oil @ 150°F 1.61 1.5Pressure drop correction 7.8x1.61 = 12.6 psi 1.5x1.61 = 2.4 psi
BTU/ HR x Cv _______________T - tambient
Q x Cv ____________Tc exit - tambient
44,538 x 1.13___________ = 2,142123.5-100
Return LineFs = 1,007
GPM = 40 "return line flow"Model = EOC - 375 - 4
Case LineFs = 2,142GPM = 8
Model = EOC - 575 - 4 - 2P
Cv VISCOSITY CORRECTION FACTORS
ISO
22
SA
E 3
0
SA
E 1
0
SA
E 5
1.381.321.271.241.191.161.040.98
1.251.201.171.131.111.091.010.97
1.151.121.101.081.051.040.990.96
1.451.401.351.291.251.221.070.99
1.111.091.061.041.031.010.980.95
50%
ET
HY
LEN
EG
LYC
OL
& W
AT
ER
PO
LYG
LYC
OL
0.920.890.880.850.840.830.790.76
PH
OS
PH
ATE
ES
TE
R0.830.800.790.770.760.740.710.69
0.850.840.840.830.820.820.800.79
Average
Liquid
Temperature
100110120130140150200250
ISO
32
1.081.061.041.031.021.020.980.95
ISO
46
1.141.131.111.091.081.060.990.96
ISO
68
1.181.161.141.131.101.091.000.96
ISO
100
1.261.251.201.171.161.131.010.96
ISO
150
1.371.311.271.241.201.171.020.97
ISO
220
1.431.391.351.301.261.221.080.99
ISO
320
1.561.481.401.341.301.271.091.01
SA
E 4
0
MIL
-L-7
808
1.191.141.091.051.031.010.980.97
SA
E 2
0
1.841.671.531.441.391.331.141.02
Cp PRESSURE DROP CORRECTION FACTORS
ISO
22
SA
E 3
0
SA
E 1
0
SA
E 5
6.405.104.203.402.902.501.400.97
4.403.603.002.602.231.901.200.92
2.402.101.801.601.501.300.960.82
8.806.705.604.503.703.101.601.05
2.001.701.501.401.301.200.930.81
50%
ET
HY
LEN
EG
LYC
OL
& W
AT
ER
PO
LYG
LYC
OL
3.002.402.101.901.901.701.201.00
PH
OS
PH
ATE
ES
TER
3.502.902.502.202.001.901.301.05
0.7300.7200.7090.6980.6860.6760.6350.556
Average
Liquid
Temperature
100110120130140150200250
ISO
32
1.071.041.020.990.970.950.890.85
ISO
46
1.531.451.381.301.231.170.990.93
ISO
68
1.821.721.601.491.381.301.080.96
ISO
100
2.542.352.151.941.751.611.181.03
ISO
150
4.193.733.262.802.382.041.331.11
ISO
220
6.445.704.914.143.472.901.591.21
ISO
320
9.388.337.236.195.204.351.741.22
SA
E 4
0
MIL
-L-7
808
1.261.201.141.081.030.980.900.83
SA
E 2
0
13.5611.63 9.73 7.80 6.11 4.77 1.95 1.23
SIZING INFORMATION
3
Copyright © 2000 American Industrial Heat Transfer, Inc.
EXAMPLE OF A MODEL
AOMF-4
AOMF-2
AOMF-1
2000
1000
800
600
500
400
300
200
21 3 4 5 6 7 8 9 10 20 30 40 50 60 80 100 200
100
AOMF SERIES
GPM
Fs
BA
C D E F G H I J
BA
C D E F G
BA
C D EF G H
H
I J K L
Horsepower to be removed (HP) x 2545 x Cv
°F (Oil Leaving✽ - Ambient Air Entering)Fs =
OIL PRESSURE DROP (PSI) CODE
BTUhr °F
=
PERFORMANCE CALCULATION
✽Represents desired fluid leaving the cooler.
D = 4 PSIE = 5 PSIF = 10 PSI
G = 15 PSIH = 20 PSI I = 25 PSI
J = 30 PSIK = 35 PSIL = 40 PSI
A = 1 PSIB = 2 PSIC = 3 PSI
PIPING HOOK UP
AOMF ELECTRIC MOTOR DATA
RPMNo. ofMotors
AirFlow
VoltsFull LoadAmperes
Model
12V / 24V
12V / 24V
12V / 24V
AOMF - 1
AOMF - 2
AOMF - 4
9 / 4.5
9 / 4.5
9 / 4.5
950
1900
3900
1
2
4
2100
2100
2100
Tubes Copper
Fins Aluminum
Turbulators Steel
Manifold Steel
Mount. bracket Steel
Cabinet Steel
Fan Blade Aluminum
Fan Guard Steel
Standard Construction Materials
STANDARD CONSTRUCTION MATERIALS
Operating Pressure 300 psig
Test Pressure 350 psig
Operating Temp. 400 oF
Standard Unit Ratings
AOMF - 1 - SAE - 24
Model
Number of motors Connections
N = NPTS = SAE
Motor Size1224
124
IN or OUTIN or OUT
OUT
IN
AOMF-SERIES STANDARD FEATURES
4
Copyright © 2000 American Industrial Heat Transfer, Inc.
Metal Conduit Of 1/2" (Flexible)
Temperature Sensor
Control Box4" x 8" x 10"
12 or 24 Volt DCSource Of Power Metal Conduit Of 3/4" (Flexible)
NOTE: Electrical Equipment Not Included. It Is Show Here For Proper Installation.
Junction Box
Relay
Fuse
Fan Motor12 or 24 Volt DC
TemperatureSwitch
Terminal Block Connections Ground
12 or 24 VoltDC
AOMF-1
AC
BF
D
GE
E
M
H
H E HAOMF-2 AOMF-4
Model MNPT WeightGFDCBA
DIMENSIONS (inches)M
SAE
14.22
28.88
27.88
11.00
24.75
24.75
16.00
16.00
29.00
15.72
29.63
29.63
9.25
9.25
23.25
17.22
30.75
30.75
13.00
13.00
26.00
30.00
45.00
75.00
1.25
1.25
1.25
AOMF - 1
AOMF - 2
AOMF - 3
20 SAE1 5/8 -12UN-2BThread
E Model
AOMF - 1
AOMF - 2
AOMF - 3
H
7.75
7.75
7.75
INSTALLATION DIAGRAM CONTROL BOX CIRCUIT
5
AOMF-SERIES STANDARD FEATURES
Copyright © 2000 American Industrial Heat Transfer, Inc.
60
30
15
1000
800
600500
400
300
200
80
6021 3 4 5 6 7 8 9 10 20 30 40 50 60 80 100 200 400
100
LP SERIES
GPM
Fs
BA
C D E F G H
BA
C D E F G
BA
C D E F G H I J
LP MOTOR DATA
12 / 24
12 / 24
12 / 24
12 / 24
12 / 24
12 / 24
LP - 15
LP - 15 - R
LP - 30
LP - 30 - R
LP - 60
LP - 60 - R
1200
1200
1200
1200
2400
2400
9.5 / 4.75
9.5 / 4.75
9.5 / 4.75
9.5 / 4.75
9.5 / 4.75
9.5 / 4.75
2200
2200
2200
2200
2200
2200
RPMAmps. VoltsCFM
Model
Horsepower to be removed (HP) x 2545 x Cv
°F (Oil Leaving✽ - Ambient Air Entering)Fs =
OIL PRESSURE DROP (PSI) CODE
BTUhr °F
=
PERFORMANCE CALCULATION
✽Represents desired fluid leaving the cooler.
D = 4 PSIE = 5 PSIF = 10 PSI
G = 15 PSIH = 20 PSI I = 25 PSI
J = 30 PSIK = 35 PSIL = 40 PSI
A = 1 PSIB = 2 PSIC = 3 PSI
Operating Pressure 300 psig
Test Pressure 350 psig
Operating Temp. 400 o F
Tubes Copper
Fins Aluminum
Turbulators Steel
Manifold Steel
Mount. bracket Steel
Cabinet Steel
Fan Blade Plastic
Fan Guard Plastic
Standard Construction Materials Standard Unit Ratings
STANDARD CONSTRUCTION MATERIALS
PIPING HOOK-UP
OUT
IN
IN or OUT IN or OUT
6
LP SERIES STANDARD FEATURES
Copyright © 2000 American Industrial Heat Transfer, Inc.
A
A
E
F
F
D
E
D
B G
J(2x)
Air Flow
J(2x)
Air Flow
Air Flow
.50ø Mounting
Holes(4x)
.50ø Mounting
Holes(4x)
KC
BC
H
GH
MODEL LP-60
MODELS LP-15 and LP-30
EXAMPLE OF A MODEL LPR - 60 - 30 - SAE
Model
Size
ConnectionsOptional
Relief ValveN = NPTS = SAE15 = One motor
30 = One motor60 = Two motors
LP
R60 = 60psiR30 = 30psi
Model JNPT
HApprox.
E FDCBA G
STANDARD DIMENSIONS (inches)
LP - 15
LP - 15 - R
LP - 30
LP - 30 - R
LP - 60
LP - 60 - R
13.88
15.88
16.47
18.72
30.72
32.97
9.00
18.00
Net WeightLBS
28
31
37
40
69
73
JSAE
KNPT
4.79
6.21
.38"DRAIN
PORT
14.25
17.25
1.50
2.50
1.00
1.50
#1615/16-12
UN-2B
#2417/8-12UN-2B
15.75
19.75
1.88
3.00
5.62
17.25
21.25
Note: Dotted line represents relief valve
7
LP SERIES STANDARD FEATURES
Copyright © 2000 American Industrial Heat Transfer, Inc.NOTES: We reserve the right to make reasonable design changes without notice.
EOC-190
EOC-220
EOC-249
EOC-337
EOC-375EOC-505
EOC-545
EOC-575
2000
1000
3000
800
500600
400
200
10021 3 4 5 6 7 8 9 10 20 30 40 50 60 80 100
300
EOC - 2PASS SERIES
GPM
Fs
BAC D E F G H I
BA
C D E F G H I
BA
C D E F G H I
B C D E F G H I J
B C D E F G H I J
J
AB C D E F
AB C D E
C EDB
F
F
G
G
H
H I
J
J
EOC-190
EOC-220
EOC-249
EOC-337
EOC-375
EOC-505
EOC-545
EOC-575
2000
1000
3000
800
500600
400
20021 3 4 5 6 7 8 10 20 30 40 50 60 80 100 200 300
300
EOC - 1PASS SERIES
GPM
Fs
BA
A
C D E F
BA
C D E F
BA
C D E F G
BA
C D E F G H
BA
C D E F G H I J
B C D E
BA
C D E
C EDB
F
F
G
G
H
H I
J
J
ELECTRIC MOTOR DATA
24
24
24
24
24
24
24
24
EOC-190
EOC-220
EOC-249
EOC-337
EOC-375
EOC-505
EOC-545
EOC-575
21 / 10.5
21 / 10.5
21 / 10.5
21 / 10.5
21 / 10.5
21 / 10.5
21 / 10.5
21 / 10.5
1 / 4
1 / 4
1 / 4
1 / 4
1 / 4
1 / 4
1 / 4
1 / 4
2000
2000
2000
2000
2000
2000
2000
2000
SEALED
SEALED
SEALED
SEALED
SEALED
SEALED
SEALED
SEALED
TypeRPMVoltsFull LoadAmperes
HorsePower
Model
NOTE: Basic electric drive units are supplied with one of the corresponding above listed motors.
12
12
12
12
12
12
12
12
Tubes Copper
Fins Aluminum
Turbulators Steel
Manifold Steel
Standard Construction Materials
STANDARD CONSTRUCTION MATERIALS
Operating Pressure 300 psig
Test Pressure 350 psig
Operating Temp. 400 oF
Standard Unit Ratings
Mount. bracket Steel
Cabinet Steel
Fan Blade Aluminum
Fan Guard Zinc Plated Steel
EOC SERIES STANDARD FEATURES
8
Copyright © 2000 American Industrial Heat Transfer, Inc.
(APPROX) 1.0
Air Flow
Air Flow
OPTIONAL FILTER
R
K
H G
CM
Q
E
B
G
AP
H
J
D (2x)
S*
MODEL EOC - 190 Through EOC - 249
MODEL EOC - 337 Through EOC - 700
( EOC - 337 Has one fan only )
MQ
K
C
BE
D
A
C (APPROX)
Air Flow
Air Flow
1.0
GH
OPTIONAL FILTER
R S*
(TOP VIEW)
* Dimension used only with two and four pass units
EOC - 190 - 4 - N - R30Model
EOC - StandardEOCF-With Filter
Size
Connection TypeN - NPTS - SAE
MotorNM- No motor4 - 12v DC6 - 24v DC
OptionalBypassR60 = 60psiR30 = 30psi
16.13 16.00 13.00
18.70 17.00 14.00
18.70 18.50 15.50
2.31
0.96
1.71
16.75
22.25
25.00
31.25
39.50
41.50
42.50
48.50
14.88
15.25
19.38
24.75
17.63
21.63
29.63
36.13
.75 #12
1.00 #16
1.25 #20
1.50 #24
2.00 #32
14.75
18.69
21.44
26.97
41.13
43.13
44.13
50.13
1.50
2.50
6.50
9.00
–
–
–
22.29
15.25
19.25
27.25
32.75
14.63
20.12
22.88
28.75
36.50
38.50
39.50
45.50
50
61
77
100
125
151
176
313
15.25
20.75
23.50
29.75
38.00
36.50
41.00
47.00
Model WeightLBS.
M PKJGED
NPT SAE
CElectric
HydraulicAC DC
BA H
DIMENSIONS (inches)
Q
EOC-190 -
EOC-220 -
EOC-249 -
EOC-337 -
EOC-375 -
EOC-505 -
EOC-545 -
EOC-575 -
.38ø x .75Slot
.56øx
.75Slot
1.31
5.31
13.13
13.58
17.63
23.88
16.38
18.62
28.38
34.88
R
10.25
10.25
15.00
19.38
12.50
16.50
24.63
30.75
S*
EXAMPLE OF A MODEL
NOTE: We reserve the right to make reasonable design changes without notice. 9
EOC SERIES STANDARD FEATURES
Copyright © 2000 American Industrial Heat Transfer, Inc.
Receiving:a) Inspect unit for any shipping damage before uncrating. If dam-aged, indicate all damages to the trucking firms' delivery person,and mark it on the receiving bill before accepting the freight. Makesure that the core and fan are not damaged. Rotate the fan blade tomake sure that it moves freely. Since the warranty is based upon theunit date code located on the model identification tag, removal ormanipulation of the identification tag will void the manufactureswarranty.
b) When handling DC heat exchanger, special care should be takento avoid damage to the core and fan. All units are shipped with woodskids for easy forklift handling.
c) Models are shipped with one coat of factory applied gray enamelsemigloss paint. A finish coat of paint should be applied to all steelsurfaces unless storage is indoors. Caution: Do Not paint the alumi-num core fins as this could impair the overall performance. Theunits are washed internally with a mineral spirit/oil solution to re-move debris and for temporary rust protection. If storage will belonger than 60 days additional rust preventative should be added tothe interior of the core. All openings are sealed with plastic pipeplugs prior to shipment. Check to make sure these are in place priorto storage.
Installation:a) Plan your installation in a location where there are no obstruc-tions to the inlet or discharge airflow path. If the unit is to be in-stalled in a wall, ample room ventilation should be provided. Ductwork or additional cooling cores added to the housing of the cooleror in front of the cooler would increase the static pressure require-ment of the fan motor thus increasing the horsepower requirementof the motor. Ducting should be slightly larger than the core areawith long radius turns to prevent added static pressure. Prevailingwinds should be considered before installing. Winds blowing heatedair back into the cooler could cause loss of cooling especially on hot
summer days.
b) We recommend that flexible hose or non-rigid plumbing be usedto reduce the risk of failure due to thermal expansion of the core andhydraulic vibration. Hydraulic carrying lines should be sized tohandle the appropriate flow and to meet system pressure drop re-quirements based upon the systems parameters, and not based uponthe units supply and return connection size. We suggest that pre-ventative filtration should be located ahead of the cooler to catchany scale or sludge for the system before it enters the cooler.
Standard oil coolers are built with a brazed core, and carry a 300-PSI maximum working pressure at 400°F maximum temperature.We suggest that a three-way thermal by-pass valve or a direct actinglow-pressure (65psi) relief valve be installed at the inlet to the coolerto protect it in cold weather environments. Units should not be placedinto a corrosive environment, as rapid deterioration of all exposedcomponents will occur resulting in shortened life or failure. For ex-ternal corrosive environments please contact our factory prior toinstallation.
c) Electric motors should be connected only to a supply power ofthe same characteristics as stamped on the electric motor name-plate. Prior to starting, rotate motor by hand to ensure that the fanand motor were not damaged during handling. Check carefully thatthe fan turns in the correct motor rotation direction. Failure to oper-ate the fan in the proper direction could reduce performance andcause serious damage to the heat exchanger.
Maintenance:a) Inspect the heat exchanger and motor for loosened bolts, connec-tions, rust spots, corrosion, fin core clogging, and external fluid leak-age.
b) Heat exchangers operating in dirty or dusty environments willoften need to have the fins of the core cleaned. Clogged fins should
SUPERIOR COOLING FINS
Seamless copper tubes are mechanically bonded to highly efficient aluminum cooling fins. Die-formed fin collars provide a durableprecision fit for maximum heat transfer.
Custom fin design forces air to become turbulent and carry heat away more efficiently than old flat fin designs.
AOMF Core LP & EOC Core
INSTALLATION & MAINTENANCE
10
Copyright © 2000 American Industrial Heat Transfer, Inc.
be cleaned by carefully brushing the fins and tubes with water or alight solvent. Use compressed air to blow and loose debris out of thefins. Rinse core with a light degreasing soap and water before rein-stalling.
c) Dirt, oil, and grease should be removed from the electric motor,fan, and fan guards. Rusty surfaces should be cleaned and re-coatedwith paint.
d) In most cases with clean hydraulic system oils it will not be nec-essary to flush the interior of the core. In circumstances where thequality of hydraulic fluid is in question, the core should be discon-nected and flushed on a yearly basis with a clean flushing oil/sol-vent to remove any sludge that has been deposited. For severe caseswhere the tubes are plugged and cannot be flushed clean with sol-vent consult factory. We suggest a filter be used at the cooler inlet toreduce the fouling of the tubes.
f) Fan blades should be cleaned and inspected for tightness on ayearly basis. When handling a fan blade care must be taken to avoidbending or striking any of the blades. The fan blades are factorybalanced and will not operate properly if bent or unbalanced. Dam-aged fan blades can cause vibration and severe damage to the heatexchanger and drive motor.
g) American Industrial has gone to great lengths to provide compo-nents that are interchangeable and repairable. If your unit gets dam-aged, chances are that you can initiate the repairs in your own shop.
American Industrial Heat Transfer, Inc., hereinafter referred to asthe "Company" warrants its commercial or industrial products againstdefects in material and workmanship under normal use and servicefor a period of one year from the date of shipment from its plant ofmanufacture.
All obligations and liabilities under this warranty are limited torepairing or replacing, at the Company's option, such as allegedlydefective products or parts as are returned, carrier charges prepaid tothe plant designated by the Company: 3905 Route 173, Zion, Illi-nois 60099. All such repairs or replacements are subject to inspec-tion by the Company of the returned products parts at the company'splant. No liability is assumed for costs relating to deinstallation orreinstallation.
Warranty on components or accessories furnished by suppliers tothe Company shall be limited to the warranty of the respective com-ponent or accessory supplier.
The Company shall not be liable for any contingent, incidental orconsequential damages for alleged failure or failure of any of its prod-ucts, components, or accessories.
If field service at the request of the Buyer is rendered by the Com-pany, and the alleged fault is found not to be with the Company'sproduct, component or accessory, the Buyer shall pay for the timeand expenses of the field representative. Bills for service , labor orother expenses that have been incurred by the Buyer, their customer
or agent, without approval or authorization by the Company, willnot be accepted.
This warranty does not cover failure resulting from the improperinstallation, mounting design or application nor does it cover failuredue to corrosion. The Company's products are not packaged or pro-tected for long periods of storages in generally corrosive atmosphericconditions.
Changes or repairs attempted or made in the field without writ-ten authorization from the Company automatically void this war-ranty.
The Company, whose policy is one of continuous improvement,reserves the right to improve its products through changes in designor material as it may deem desirable without being obligated to in-corporate such changes in products of prior manufacture.
WARRANTY PROCEDURESIf you've experienced a problem with your equipment and feel thatit is a warranty matter, or you have equipment that needs to be re-paired or replaced, contact American Industrial through your localdistributor. The basic information that you will need to begin theprocess is the complete name plate data.
UNITS WILL NOT BE ACCEPTED FOR RETURN UNLESS AN RGA NUMBER
HAS BEEN ASSIGNED BY AMERICAN INDUSTRIAL, AND THE UNIT IS SHIPPED
PREPAID.
WARRANTY
Most parts of heat exchanger cabinets are made of 18 gauge metalsthat can be bent back into position after external damage. The coreis of brazed construction. Core replacement is suggested if it is everdamaged to the point of leakage. Please consult American Indus-trial for specific repair details.
Return Goods:If you are returning a product for credit, evaluation, or repair, youmust obtain a Return Goods Authorization (RGA) number fromAmerican Industrial. Return goods must be shipped prepaid. A de-tailed written reason for return must accompany the shipment alongwith the RGA reference number clearly on the label. Failure to fol-low return procedures could result in lost items, delays, additionalservice charges, warrantee denial, or refusal of shipment.
All items being returned for restock to American Industrial are sub-ject to a restocking charge. Items sent for service, evaluation or re-conditioning are subject to a basic service charge. Please refer to thebooklet or contact American Industrial or your local distributor formore detailed information regarding the American Industrial HeatTransfer, Inc. return goods policy.
Review:1) Contact American Industrial to obtain a RGA number.2) Securely package shipment to prevent damage to the items.3) Clearly label the shipping container with the RGA number and your company information.4) Ship by designated freight carrier "Prepaid".
11
INSTALLATION & MAINTENANCE
Copyright © 2000 American Industrial Heat Transfer, Inc.
CNC high accuracy mills and lathes produce precision parts. A full line of engineering services are available to assist withtechnical support, design, Cad drawings, etc…
American Industrial's state-of-the-art manufacturing facility.
Since 1985, American Industrial Heat Transfer, Inc. is pleased to offer more than thirty fully manufactured product lines toresolve your heat transfer needs. Our company manufactures all of the heat exchangers as advertised, so that your company is nevercompromised. Modern state-of-the-art CNC manufacturing machinery, top quality raw materials, and professional engineeringservices all offered at one source.
Many innovative liquid and air-cooled heat exchanger designs are offered for a wide variety of mobile and industrial applica-tions. The latest technology data processing, manufacturing, and CAD systems are employed throughout our company.
American Industrial is proud to offer one of the strongest authorized distribution networks in the industry with worldwidecoverage. Direct access to professional engineering services, no service charge 24 hour expedite delivery, custom modifications,competitive pricing, etc... are just a few benefits of being an American Industrial customer.
We know that our future relies on the future of our customers. For that reason we have invested in high-technology automationand professional personnel to give us the competitive edge far into the next millennium.
If you would like to know more about our products, please contact your local American Industrial distributor or contact ourcompany. We appreciate your business and we hope to share with you in your successes.
MISSION STATEMENT
To manufacture Heat Transfer products by applying state-of-the-art technologies, with the ability to serve a widevariety of industries through professional distribution affiliations throughout North America and abroad.
12
COMPANY PROFILE
Copyright © 2000 American Industrial Heat Transfer, Inc.
• Application assistance• Certificate of conformance• Certificate of test• Computerized selection sheet• Materials certificate• CAD Drawings
Our sales specialists are always available to pro-vide help with your requests. To contact one of oursales specialist please call 1-800-338-5959 (847-731-1000) of fax your needs to 847-731-1010. Our salesoffice is open Monday through Friday from 7:00 AM -5:00 PM CST.
To contact our accounting services office pleasecall 847-731-1057 or fax your correspondence to 847-731-3440. Our accounting services is open Tuesdaythrough Friday from 9:00 AM - 3:30 PM CST.
STREET & MAILING ADDRESS:American Industrial Heat Transfer, Inc.3905 Route 173Zion, IL 60099
ACCOUNTING REMIT TO:American Industrial Heat Transfer, Inc.Department 77-2634Chicago, IL 60678-2634
For accurate technical answers contact our tech-nical services department at 847-731-1055, or fax yourrequirements to 847-731-3440. A complete offering ofproduct engineering and application services are al-ways available Monday through Friday from 7:30 AM- 5:00 CST.
• Order entry• Trafficking• Catalog literature• Administrative services• Sales• Distribution• Pricing
• Accounts receivable.• Accounts payable.• Account information.
TECHNICAL
SALES
ACCOUNTING
LOCATION
O'Hare Field
Mitchel l Field
50
Wisconsin
I l l i no i s
State Line
31
131
Russell Road
Gre
en
Ba
y R
d.
41
173
0.4 miles
Kie
fer
American Industrial
Ken
osha
Rd.
Sh
eri
da
n R
d.
ToMilwaukee
ToChicago
ZION LakeMichigan
N
E
S
W
41
Kie
fer
Dr.
4.5 miles
294
Tri
-Sta
te T
oll
wa
y
90
90
190
94
94
94
Approx. 35 milesfrom Mitchell
Approx. 40 milesfrom O'Hare
"American Industrial Heat Transfer, Inc. greatly
appreciates your business. We are dedicated to
do everything humanly possible to provide the
highest quality products and services at the lowest
possible prices."
"Thank you for your consideration and
patronage. We are always aware that you, as a
customer, have many choices available. We are
sincerely grateful to you for choosing American
Industrial Heat Transfer, Inc. and trusting our
company as your supplier of heat exchanger
products."13
SERVICES
Copyright © 2000 American Industrial Heat Transfer, Inc.
AOCH Series• Industrial high capacity air/oil heat exchanger available in 8 standard sizes with electric or hydraulic drive.
AOCH Series with screen & Serviceable Core™
AC,ACHM & ACF Series• Industrial air/oil heat exchanger available in 8 standard sizes with electric or
hydraulic drive.
ACA Series• Heavy-duty Serviceable Core™ air cooled air after-coolers for compressor
sizes up to 500 HP.
AOCH Series• Heavy duty Serviceable Core™ construction.
• Eight sizes in stock for immediate delivery.• Electric & hydraulic drive.
AC Series• Industrial duty construction.
• Eight sizes in stock for immediate delivery.• Electric & hydraulic drive.
AOCH Series with louvers & Serviceable Core™
AVAILABLE PRODUCTS
14
Copyright © 2000 American Industrial Heat Transfer, Inc.
BM Series• Air/ oil coolers designed for small heat removal requirements to be mounted directly to the vent side of TEFC electric motors. NEMA frame sizes from 48 to 184.
AOM & AOMR Series• Mobil oil coolers for applications not requiring a fan motor.
BM-131 Thru BM-142 Series• Light duty 115V fan cooled heat exchangers for low flow applications.
EOC Series with hydraulic motor EOC Series with electric motor & filter as an option.
EOC Series• Versatile industrial/mobil grade heat exchanger available with Optional Filter, AC, DC, and hydraulic drives.
AOCS Series• Heavy duty Serviceable Core™ construction.
• Eight sizes in stock for immediate delivery.• Electric, hydraulic, or external drive.
BM-101 BM-102 BM-201 Thru BM-322
15
AVAILABLE PRODUCTS
AOCS Series• Heavy duty Serviceable Core™ construction.
• Eight sizes in stock for immediate delivery.• Electric, hydraulic, or external drive.
AB Series• Variety of sizes from 2"-8" diameters, available in brass, 316L Stainless Steel.
AA Series• Variety of sizes from 2"-8" diameters, available in a wide range of materials.
URCS Series• U-tube heat exchangers for steam services with removable tubes bundle in
copper, 316L SS, or 90/10 Cu Ni.
FBF Series• Fixed tube construction with SAE O-Ring or Four Bolt Flanges. Sizes from
2" through 10" diameters.
AB 2000-6000 Series• High capacity shell & tube heat exchangers, available in sizes from
10"-32" diameters.
CS Series• Variety of sizes from 2"-8" diameters, available in a wide range of
materials.
AVAILABLE PRODUCTS
16
3905 Route 173 Zion, Illinois 60099Telephone: (800) 338-5959 or (847) 731-1000
FAX: (847) 731-1010Copyright © 2000 American Industrial Heat Transfer, Inc.