100W ETA-USA 16170 Vineyard Blvd. Suite 180 Morgan Hill, CA 95037 http://www.eta-usa.com Toll-free (US only): 800-ETA-POWR (800-382-7697) Telephone: 408 778-2793 FAX: 408-779-2753 The Power Professionals ETA-USA Output Voltage Voltage Adjustment Range Rise Time Vdc Ripple and Noise mVp MODEL/CHANNEL - - Unit FEATURES OUTPUT (Single) ETD-SC/ETD-SD ETD05- SC48-U1 Line Regulation Load Regulation Temp. Coefficient Drift Drift Dynamic Load Regulation mV mV mV mV mV mV ±10% of rated output voltage ±10% of rated output voltage 200 • Light weight, compact size • High efficiency, high reliability • Input under voltage protection • Over current, over voltage, thermal protection • CE • Isolated Power Supply 580 340 250 220 150 2 4.2 6.7 8.4 120 120 120 100 40 26 20 48 24 15 12 5 3.3 2.5 135 135 135 110 45 30 23 15 7.5 4.5 3.6 1.5 1 0.75 260 135 90 75 32 32 28 1200 1200 600 750 250 250 500mS(maximum) at 25°C and rated input/output 500mS(maximum) at 25°C and rated input/output Output Voltage Voltage Adjustment Range Rise Time Vdc Output Current A Ripple and Noise mVp MODEL/CHANNEL - - Unit OUTPUT (Single) ETD3.3- SC48-U1 ETD2.5- SC48-U1 ETD24- SC48-U1 ETD48- SC48-U1 Line Regulation Load Regulation Temp. Coefficient Dynamic Load Regulation mV mV mV mV ETD15- SC48-U1 ETD12- SC48-U1 Output Current A 20 25 25

Upload: others

Post on 24-Jan-2021

17 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: ETA-USAETD1.8-SC300-U1 Line Regulation Load Regulation Temp. Coefficient Drift Drift Dynamic Load Regulation mV mV mV mV mV mV 1.8 ±10% of rated output voltage ±10% of …

100W

ETA-USA 16170 Vineyard Blvd. Suite 180 Morgan Hill, CA 95037 http://www.eta-usa.comToll-free (US only): 800-ETA-POWR (800-382-7697) Telephone: 408 778-2793 FAX: 408-779-2753

The Power ProfessionalsETA-USA

Output Voltage

Voltage Adjustment RangeRise Time

Vdc

Ripple and Noise mVp

MODEL/CHANNEL

--

Unit

FEATURES

OUTPUT(Single)

ETD-SC/ETD-SD

ETD05-SC48-U1

Line RegulationLoad Regulation

Temp. CoefficientDrift

Drift

Dynamic Load Regulation

mVmV

mVmVmV

mV

±10% of rated output voltage

±10% of rated output voltage

200

• Light weight, compact size • High efficiency, high reliability • Input under voltage protection • Over current, over voltage, thermal protection • CE• Isolated Power Supply

580340250220

150

24.26.78.4120120120100

402620

48241512

53.32.5

135135135110

453023

157.54.53.6

1.510.75

2601359075

323228

12001200600 750

250 250

500mS(maximum) at 25°C and rated input/output

500mS(maximum) at 25°C and rated input/output

Output Voltage

Voltage Adjustment RangeRise Time

VdcOutput Current A

Ripple and Noise mVp

MODEL/CHANNEL

--

UnitOUTPUT(Single)

ETD3.3-SC48-U1

ETD2.5-SC48-U1

ETD24-SC48-U1

ETD48-SC48-U1

Line RegulationLoad Regulation

Temp. Coefficient

Dynamic Load Regulation

mVmV

mVmV

ETD15-SC48-U1

ETD12-SC48-U1

Output Current A 202525

Page 2: ETA-USAETD1.8-SC300-U1 Line Regulation Load Regulation Temp. Coefficient Drift Drift Dynamic Load Regulation mV mV mV mV mV mV 1.8 ±10% of rated output voltage ±10% of …

ETA-USA 16170 Vineyard Blvd. Suite 180 Morgan Hill, CA 95037 http://www.eta-usa.comToll-free (US only): 800-ETA-POWR (800-382-7697) Telephone: 408 778-2793 FAX: 408-779-2753

The Power ProfessionalsETA-USA

Output Voltage

Voltage Adjustment RangeRise Time

Vdc

Ripple and Noise mVp

MODEL/CHANNEL

--

UnitOUTPUT(Single)

ETD05-SC300-U1

ETD1.8-SC300-U1

Line RegulationLoad Regulation

Temp. CoefficientDrift

Drift

Dynamic Load Regulation

mVmV

mVmVmV

mV

1.8

±10% of rated output voltage

±10% of rated output voltage

1516

0.5424

200 200

580340250220

150

24.26.78.4120120120100

402620

48241512

53.32.5

135135135110

453023

157.54.53.6

1.510.75

2601359075

323228

12001200600 750

250 250

500mS(maximum) at 25°C and rated input/output

500mS(maximum) at 25°C and rated input/output

Output Voltage

Voltage Adjustment RangeRise Time

VdcOutput Current A

Ripple and Noise mVp

MODEL/CHANNEL

--

UnitOUTPUT(Single)

ETD3.3-SC300-U1

ETD2.5-SC300-U1

ETD24-SC300-U1

ETD48-SC300-U1

Line RegulationLoad Regulation

Temp. Coefficient

Dynamic Load Regulation

mVmV

mVmV

ETD15-SC300-U1

ETD12-SC300-U1

Output Current A 20252525

Page 3: ETA-USAETD1.8-SC300-U1 Line Regulation Load Regulation Temp. Coefficient Drift Drift Dynamic Load Regulation mV mV mV mV mV mV 1.8 ±10% of rated output voltage ±10% of …

INPUTUnit

Unit

MODEL/CHANNEL

MODEL/CHANNEL

UnitMODEL/CHANNEL

UnitMODEL/CHANNEL

-

-

--

---

Dimension

Environment

mm/gSize(WxHxD)/Weight

Operating TemperatureOperating HumidityStorage TemperatureWithstand Voltage

Vibration

Safety

℃%℃

%Primary-Secondary DeratingStorage HumidityIsolation ResistanceShockCooling

-

--

Protection Over Current Protection A

Over Voltage Protection105% of Rated Output Current

Current Limiting. Output shutdown when voltage drops to 50% of rated output voltage (60% at ETD1.8SC300) turn on 1minute after shut down to restart

115% of Rated Output voltage Turn on 1 minute after shutdown to restart

Input Voltage Range

kHz

Vdc Vdc Input Voltage 48V

%HRef. MTBF

Switching Frequency

Efficiency

Input Voltage Range

kHz

VdcVdcInput Voltage 300V

%

Switching Frequency

Efficiency

kHz

%HRef. MTBF

Switching Frequency

Efficiency

ETD12-SC48-U1

ETD05-SC48-U1

ETD3.3-SC48-U1

ETD2.5-SC48-U1

ETD05-SC300

ETD3.3-SC300

ETD2.5-SC300

ETD1.8-SC300

ETD48-SC300

ETD24-SC300

ETD15-SC300

ETD12-SC300

ETD15-SC48-U1

ETD24-SC48-U1

ETD48-SC48-U1

* Input fuse is installed in unit * Common mode filter is installed at the input side of unit

AvailableAvailable

Remote SenseRemote On/Off

-10 to +50°C

-20 to +85°CPrimary-Secondary AC 3,000V at 20mA for 1 minute

Primary-Frame Ground AC 2,000V at 20mA for 1 minuteSecondary-Frame Ground AC 1,000V at 20mA for 1 minute

5-10Hz: 10mm double amplitude, 10-55Hz: 19.6m/s^2,each along X, Y, Z axes (non-operating)

196m/s^2Convection

CE

W56×L86×H30/200g

DC48VDC36-72V

93

DC300VDC200-400V

110 Fix.

90.5

288,000289,000275,000170 Fix.150 Fix.

94.594

275,000

94.5

92.5 94.592.2

100 Fix.130 Fix.

130 Fix.

160 Fix.

20-90%/RH (non-condensing)

20 to 90%/RHPrimary-Secondary-Frame Ground 100M ohm (minimum) by DC500V insulation tester

ETA-USA 16170 Vineyard Blvd. Suite 180 Morgan Hill, CA 95037 http://www.eta-usa.comToll-free (US only): 800-ETA-POWR (800-382-7697) Telephone: 408 778-2793 FAX: 408-779-2753

The Power ProfessionalsETA-USA

HRef. MTBF 288,000289,000264,000

Page 4: ETA-USAETD1.8-SC300-U1 Line Regulation Load Regulation Temp. Coefficient Drift Drift Dynamic Load Regulation mV mV mV mV mV mV 1.8 ±10% of rated output voltage ±10% of …

100W

ETA-USA 16170 Vineyard Blvd. Suite 180 Morgan Hill, CA 95037 http://www.eta-usa.comToll-free (US only): 800-ETA-POWR (800-382-7697) Telephone: 408 778-2793 FAX: 408-779-2753

The Power ProfessionalsETA-USA

Dimension Diagram (mm)

Page 5: ETA-USAETD1.8-SC300-U1 Line Regulation Load Regulation Temp. Coefficient Drift Drift Dynamic Load Regulation mV mV mV mV mV mV 1.8 ±10% of rated output voltage ±10% of …

OCP Curve

ETA-USA 16170 Vineyard Blvd. Suite 180 Morgan Hill, CA 95037 http://www.eta-usa.comToll-free (US only): 800-ETA-POWR (800-382-7697) Telephone: 408 778-2793 FAX: 408-779-2753

The Power ProfessionalsETA-USA

Efficiency Curve

100WMounting Positions

ETDxSC300 ETDxSC300