Water Source Heat Pump Rooftop Range

Designed for High efficiency.• Eurovent Certified• High efficiency stainless steel Heat Exchanger

Designed for Reliability.• Benefits from our extensive experience with Rooftop design • Dual circuit or tandem refrigeration circuits• Many hydraulic safety features as standard

Designed around our current Baltic and Flexy R410a Range.• Common option list• No change in casing (base frame & air treatment section)• R410a refrigerant• Common refrigeration components

Page 3: EUROPEAN SALES TOUR 2009 1 2009 Water Source Heat Pump Systems

Water Source Heat Pump Rooftop Range

The Name.

B W H 075 D N M 1

F W H 120 D N M 1

BalticFlexy

Water cooled

Heat PumpMulti Fuel

Unit Size045 170

S= 1 CircuitD= 2 Circuits

High HeatStandard HeatNo Heat

Revision Number

M = R410a

Page 4: EUROPEAN SALES TOUR 2009 1 2009 Water Source Heat Pump Systems

Water Source Heat Pump Rooftop Range

The Range

Cooling Capacity rated at: Water 30°C --> 35°C Indoor conditions: 27°CDB / 19°CWB

BWH 045

BWH 055

BWH 065

BWH 075

FWH085

FWH100

FWH120

FWH150

FWH170

Nominal Airflow Rate 8100 9000 11500 14200 15000 18500 20500 26000 30000Net Cooling capacity (KW) 48 60 73 85 93 124 138 165 194EER Gross 5,1 5,0 5,2 5,2 5,0 5,1 5,1 5,2 5,0EER Net 4,1 4,1 4,4 4,1 4,0 4,1 4,1 4,2 4,0

Heating Capacity rated at: Water inlet 20°CIndoor conditions: 20°CDB

BWH 045

BWH 055

BWH 065

BWH 075

FWH085

FWH100

FWH120

FWH150

FWH170

COP Heating Gross 5,0 4,8 5,1 5,1 5,1 5,1 4,9 5,3 5,1COP Heating Net 4,2 4,3 4,7 4,4 4,4 4,4 4,2 4,6 4,4

Summer 27°CDB/19°CWB water 30-35°CWinter 20°CDB water inlet 20°C

Page 5: EUROPEAN SALES TOUR 2009 1 2009 Water Source Heat Pump Systems

Water Source Heat Pump Rooftop Range

The Refrigeration circuit

• Refrigerant R410a• Scroll compressors mounted single or tandem• Thermostatic Expansion valves• Stainless Steel 316 heat exchanger• 4 Way valve for reversibility• Filter drier• High and Low pressure safety switches• Fully assembled and leak tested

Same compressor arrangement as on air cooled version.

Page 6: EUROPEAN SALES TOUR 2009 1 2009 Water Source Heat Pump Systems

Water Source Heat Pump Rooftop Range

The Hydraulic Circuit

As standard the water cooled range will be equipped with the following features:

• Low Pressure Drop (>50 kPa)• Stainless Steel Plate Heat Exchanger• Victaulic Connections & Couplings• Air vent on the highest point • Water filter• Electronic water flow switch• Pressure taps inlet and outlet• Fully insulated hydraulic parts when located inside the unit

Option: Low water loop temperature option through flow control to maintain Refrigerant High Pressure

Page 7: EUROPEAN SALES TOUR 2009 1 2009 Water Source Heat Pump Systems

Water Source Heat Pump Rooftop Range

Electronic flow switch

More Accurate• No risk of offset in time• Very Accurate flow measurementMore Reliability• No moving part• No Maintenance• No risk of blockage• Can work with any kind of fluid (glycol)• One single reference for the whole range• Easy to install• Stainless steel construction

FLOWHeat is dissipated by the fluid

NO FLOWHeat is not dissipated by the fluid

Page 8: EUROPEAN SALES TOUR 2009 1 2009 Water Source Heat Pump Systems

Water Source Heat Pump Rooftop Range

Air Treatment Section

• Identical to the air cooled version, • The performance tables for ventilation / pressure drop remain unchanged

Most of the air treatment features and options are compatible with this new range (Filters, Economiser, CO2 sensors heat recovery modules…)

Air Flow Configurations