flomatic pressure reducing valves reducing... · the flomatic pressure reducing valve (prv) model...

4
Pressure Reducing Valve Residential and Commercial Water Systems Model C150E 1/2” thru 2” High capacity globe style design Unleaded Bronze Body NSF/ANSI 61-2010 certified by IAPMO R&T NSF/ANSI 372 UNLEADED VALVES Flomatic Valves High Quality Valves Built to Last... High Quality Valves Built to Last… Click to see: Pressure Reducing Valves in our Online Catalog

Upload: truongkhanh

Post on 10-Mar-2019

221 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Flomatic Pressure Reducing Valves Reducing... · The Flomatic Pressure Reducing Valve (PRV) Model C150E when properly installed will regulate high upstream (inlet pressure) to a lower

Delivers constant pressure automaticallyDomestic well water systemsMunicipal / Public water systemsIrrigation and sprinkler systemsPump booster systems

FEATURESSizes 1/2”, 3/4”, 1”, 11/4” , 2”Maximum Pressure 400 psiReduced Pressure Ranges 15 psi to 75 psi,15 psi to150 psiMaximum Water Temperature 1800FFactory pre-set 50 psiStandard Thread Connections (FNPT) ANSI B 1.20.1

STANDARD COMPLIANCEASSE® LISTED 1003IAPMO® LISTEDCSA® LISTED (1/2” thru 11⁄4”)CITY OF LOS ANGELES APPROVEDNSF/ANSI 61-2010 CERTIFIED BY IAPMO R&T (1/2” thru 11⁄4”)NSF/ANSI 372

Double Threaded End ConnectionsSimplify installation with pipe size flexibility. Standard models areequipped with one union end connection and male/female threadedconnection on the other valve end. Several different end-connection and sizes are available.

Note: Valve fully open with no spring, for fall of curve consult factory or visit website.Flomatic can accept no responsibility for possible errors in catalogues, brochures and other printed material. Flomatic reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed. All trademarks in this material are property of the respective companies. Flomatic and the Flomatic logotype are trademarks of Flomatic. All rights reserved.

HEAD LOSS CHARTS

Pressure Reducing ValveResidential and Commercial Water Systems

Model C150E

1/2” thru 2”

High capacity globe style design

Unleaded Bronze Body

NSF/ANSI 61-2010 certified by IAPMO R&T

NSF/ANSI 372

Flomatic Corporation 15 Pruyn’s Island Drive

Glens Falls, NY 12801-4421

Telephone: 1-(800)-833-2040 Direct Telephone: 1-(518)-761-9797

Fax: 1-(800)-314-3155 Direct Fax: 1-(518)-761-9798

www.flomatic.com

High Quality Valves Built to Last...Flomatic Valves

© Copyright 2014 by Flomatic #Y150E Rev. 2/14

UNLEADED VALVES

UNLEADED VALVES

Flomatic ValvesHigh Quality Valves Built to Last...

One of the lowest flow losses in the industry

High Quality Valves Built to Last…

27595 C150E_C150E 3/27/14 8:37 AM Page 1

Click to see: Pressure Reducing Valves in our Online Catalog

Page 2: Flomatic Pressure Reducing Valves Reducing... · The Flomatic Pressure Reducing Valve (PRV) Model C150E when properly installed will regulate high upstream (inlet pressure) to a lower

FEATURES/BENEFITSHigh capacity globe style design

Single union with FNTP tailpiece standard, inlet and outlet both male threaded for union on either or both sides.Replaceable acetal cartridge with integral stainless steel strainerBuilt-in bypass prevents buildup of excessive system pressure caused by thermal expansion

Nylon reinforced Buna-N diaphragm

Balanced piston design

May be installed in any position

Short lay length makes for easy retrofit

No special tools required

Serviceable in-line

Available with BSPT threads (optional)

SIZE CONNECTIONS A B C D WEIGHT

1/2” Single Union 43/8” 61/8” 11/32” 23/8” 3 lbs

1/2” Less Union 31/2” 61/8” 11/32” 23/8” 3 lbs

1/2” Double Union 51/4” 61/8” 11/32” 23/8” 3 lbs

3/4” Single Union 47/16” 61/8” 11/32” 23/8” 3 lbs

3/4” Less Union 31/2” 61/8” 11/32” 23/8” 3 lbs

3/4” Double Union 53/8” 61/8” 11/32” 23/8” 3 lbs

1” Single Union 415/16” 75/8” 11/8” 3” 4 lbs

1” Less Union 4” 75/8” 11/8” 3” 4 lbs

1” Double Union 57/8” 75/8” 11/8” 3” 4 lbs

11/4” Single Union 63/16” 83/8” 19/16” 3” 5.3 lbs

11/4” Less Union 5” 83/8” 19/16” 3” 5.3 lbs

11/4” Double Union 73/8” 83/8” 19/16” 3” 5.3 lbs

11/2” Single Union 75/64” 915/16” 23/16” 53/16” 14.5 lbs

11/2” Less Union 513/16” 915/16” 23/16” 53/16” 13.5 lbs

11/2” Double Union 811/32” 915/16” 23/16” 53/16” 15.5 lbs

2” Single Union 75/64” 915/16” 23/16” 53/16” 15.3 lbs

2” Less Union 513/16” 915/16” 23/16” 53/16” 14.3 lbs

2” Double Union 811/32” 915/16” 23/16” 53/16” 16.3 lbs

Part # C150099E 15 - 75 psi Part # C150199E 15 - 150 psi* On 1/2” - 11/4” only

Item # Qty. Description Material Item # Qty. Description Material

1 1 Adjusting Screw Steel 15 1 Large Washer Stainless Steel18-8

2 1 *Spacer ABS 16 1 Stem Stainless Steel304

3 1 Jam Nut Steel or Bronze 17 1 O-Ring Buna-n

4 1 Valve Cover Noryl or 89833 18 1 Cartridge Delrin

5 1 Spring Button Steel 19 1 Disc Holder Stainless Steel304

6 1 Spring Steel 20 1 Disc EPDN

7 1 HHCS Stainless Steel 18-8 21 1 Plastic Washer Delrin

8 1 Diaphragm Plate Steel 22 1 HHCS Stainless Steel18-8

9 1 Tooth Lock Washer Steel 23 1 Small Washer Stainless Steel18-8

10 1 O’Ring Buna-n 24 1 Body Bronze C89833

11 1 O’Ring Buna-n 25 1 Union Disc EPDM

12 1 Diaphragm Nitrile / Nylon 26 1 Union Nut Bronze C31400

13 1 Screen Stainless Steel 27 1 Union Bronze C31400

14 1 Friction Ring Brass C36000 - - - -

www.flom

atic.com

C150E Control Valve Model PRV w

ww.flom

atic.com C150E C

ontrol Valve Model P

RV

1 2

PRODUCT SPECIFICATIONConnection: NPT (Male/Female)Max pressure: 400 PSI (27 bar)Max temperature: 180oF (80oC)Pressure Regulating Setting: Factory set at 50 psiStandard spring adjustment range: Valve sizes: 1/2” thru 2”: 15 to 75 psi *Maximum pressure reduction ratio 4:1

* Optional spring ranges available for this valve are 15 - 150 psi spring

PRODUCT OPTIONS

DELIVERS CONSTANT PRESSURE AUTOMATICALLY

11/2” thru 2”

ITEM / QUANITY / DESCRIPTION / MATERIAL

D

B

C

A

FLOMATIC VALVES

MATERIALSValve body: Un-leaded bronze

Valve cover: Composite (1/2”, 3/4”, 1” & 11/4”)

Unleaded bronze valve cover (11/2” thru 2”)

Spring & fasteners: Stainless steel

Internal parts: Corrosion resistant

END-CONNECTIONS

DIMENSIONS

Corrosion resistantinternal parts

Un-leaded bronzevalve body

Stainless Steel spring & fasteners

Composite bellhousing

FLOMATIC VALVES

UNLEADED VALVES

PRODUCT OPERATIONThe Flomatic Pressure Reducing Valve (PRV) Model C150E when properly installed will regulate highupstream (inlet pressure) to a lower regulated downstream (outlet pressure) constant pressure within a range regardless of water flow. This is accomplished by an adjustable spring loaded balancing valvefactory set to automatically regulate the downstream pressure to 50 psi. The regulating pressure is field adjustable. Bypass should be considered for low flow application.

MODEL

C150E

C150ET

Standard Model Un-leaded valve body

Un-leaded valve body

Female/NPT Union

Female/Male NPT(No Union Nut)

Single Union EndW/Female NPT

Female/Male NPT(No Union Nut)

C150EPEX Un-leaded valve body PEX PEX

DESCRIPTION INLET OUTLET

SizeFLOMATIC(proposed)

WILKINS WATTSAPPOLO

CONBRACO

Series C150EC150E PEX

3/4” & 1”Series NR3NR3XL PEX

Series LFN45LFN45BDU-PEX-M1

Series 36CLFPRC-D-0-0-H-L-X-LF

Double Union Cross-Reference Guide – PEX union inlet and outlet (3/4” and 1” only)

27595 C150E_C150E 3/27/14 8:37 AM Page 2

Page 3: Flomatic Pressure Reducing Valves Reducing... · The Flomatic Pressure Reducing Valve (PRV) Model C150E when properly installed will regulate high upstream (inlet pressure) to a lower

FEATURES/BENEFITSHigh capacity globe style design

Single union with FNTP tailpiece standard, inlet and outlet both male threaded for union on either or both sides.Replaceable acetal cartridge with integral stainless steel strainerBuilt-in bypass prevents buildup of excessive system pressure caused by thermal expansion

Nylon reinforced Buna-N diaphragm

Balanced piston design

May be installed in any position

Short lay length makes for easy retrofit

No special tools required

Serviceable in-line

Available with BSPT threads (optional)

SIZE CONNECTIONS A B C D WEIGHT

1/2” Single Union 43/8” 61/8” 11/32” 23/8” 3 lbs

1/2” Less Union 31/2” 61/8” 11/32” 23/8” 3 lbs

1/2” Double Union 51/4” 61/8” 11/32” 23/8” 3 lbs

3/4” Single Union 47/16” 61/8” 11/32” 23/8” 3 lbs

3/4” Less Union 31/2” 61/8” 11/32” 23/8” 3 lbs

3/4” Double Union 53/8” 61/8” 11/32” 23/8” 3 lbs

1” Single Union 415/16” 75/8” 11/8” 3” 4 lbs

1” Less Union 4” 75/8” 11/8” 3” 4 lbs

1” Double Union 57/8” 75/8” 11/8” 3” 4 lbs

11/4” Single Union 63/16” 83/8” 19/16” 3” 5.3 lbs

11/4” Less Union 5” 83/8” 19/16” 3” 5.3 lbs

11/4” Double Union 73/8” 83/8” 19/16” 3” 5.3 lbs

11/2” Single Union 75/64” 915/16” 23/16” 53/16” 14.5 lbs

11/2” Less Union 513/16” 915/16” 23/16” 53/16” 13.5 lbs

11/2” Double Union 811/32” 915/16” 23/16” 53/16” 15.5 lbs

2” Single Union 75/64” 915/16” 23/16” 53/16” 15.3 lbs

2” Less Union 513/16” 915/16” 23/16” 53/16” 14.3 lbs

2” Double Union 811/32” 915/16” 23/16” 53/16” 16.3 lbs

Part # C150099E 15 - 75 psi Part # C150199E 15 - 150 psi* On 1/2” - 11/4” only

Item # Qty. Description Material Item # Qty. Description Material

1 1 Adjusting Screw Steel 15 1 Large Washer Stainless Steel18-8

2 1 *Spacer ABS 16 1 Stem Stainless Steel304

3 1 Jam Nut Steel or Bronze 17 1 O-Ring Buna-n

4 1 Valve Cover Noryl or 89833 18 1 Cartridge Delrin

5 1 Spring Button Steel 19 1 Disc Holder Stainless Steel304

6 1 Spring Steel 20 1 Disc EPDN

7 1 HHCS Stainless Steel 18-8 21 1 Plastic Washer Delrin

8 1 Diaphragm Plate Steel 22 1 HHCS Stainless Steel18-8

9 1 Tooth Lock Washer Steel 23 1 Small Washer Stainless Steel18-8

10 1 O’Ring Buna-n 24 1 Body Bronze C89833

11 1 O’Ring Buna-n 25 1 Union Disc EPDM

12 1 Diaphragm Nitrile / Nylon 26 1 Union Nut Bronze C31400

13 1 Screen Stainless Steel 27 1 Union Bronze C31400

14 1 Friction Ring Brass C36000 - - - -

www.flom

atic.com

C150E Control Valve Model PRV w

ww.flom

atic.com C150E C

ontrol Valve Model P

RV 1 2

PRODUCT SPECIFICATIONConnection: NPT (Male/Female)Max pressure: 400 PSI (27 bar)Max temperature: 180oF (80oC)Pressure Regulating Setting: Factory set at 50 psiStandard spring adjustment range: Valve sizes: 1/2” thru 2”: 15 to 75 psi *Maximum pressure reduction ratio 4:1

* Optional spring ranges available for this valve are 15 - 150 psi spring

PRODUCT OPTIONS

DELIVERS CONSTANT PRESSURE AUTOMATICALLY

11/2” thru 2”

ITEM / QUANITY / DESCRIPTION / MATERIAL

D

B

C

A

FLOMATIC VALVES

MATERIALSValve body: Un-leaded bronze

Valve cover: Composite (1/2”, 3/4”, 1” & 11/4”)

Unleaded bronze valve cover (11/2” thru 2”)

Spring & fasteners: Stainless steel

Internal parts: Corrosion resistant

END-CONNECTIONS

DIMENSIONS

Corrosion resistantinternal parts

Un-leaded bronzevalve body

Stainless Steel spring & fasteners

Composite bellhousing

FLOMATIC VALVES

UNLEADED VALVES

PRODUCT OPERATIONThe Flomatic Pressure Reducing Valve (PRV) Model C150E when properly installed will regulate highupstream (inlet pressure) to a lower regulated downstream (outlet pressure) constant pressure within a range regardless of water flow. This is accomplished by an adjustable spring loaded balancing valvefactory set to automatically regulate the downstream pressure to 50 psi. The regulating pressure is field adjustable. Bypass should be considered for low flow application.

MODEL

C150E

C150ET

Standard Model Un-leaded valve body

Un-leaded valve body

Female/NPT Union

Female/Male NPT(No Union Nut)

Single Union EndW/Female NPT

Female/Male NPT(No Union Nut)

C150EPEX Un-leaded valve body PEX PEX

DESCRIPTION INLET OUTLET

SizeFLOMATIC(proposed)

WILKINS WATTSAPPOLO

CONBRACO

Series C150EC150E PEX

3/4” & 1”Series NR3NR3XL PEX

Series LFN45LFN45BDU-PEX-M1

Series 36CLFPRC-D-0-0-H-L-X-LF

Double Union Cross-Reference Guide – PEX union inlet and outlet (3/4” and 1” only)

27595 C150E_C150E 3/27/14 8:37 AM Page 2

Page 4: Flomatic Pressure Reducing Valves Reducing... · The Flomatic Pressure Reducing Valve (PRV) Model C150E when properly installed will regulate high upstream (inlet pressure) to a lower

Delivers constant pressure automaticallyDomestic well water systemsMunicipal / Public water systemsIrrigation and sprinkler systemsPump booster systems

FEATURESSizes 1/2”, 3/4”, 1”, 11/4” , 2”Maximum Pressure 400 psiReduced Pressure Ranges 15 psi to 75 psi,15 psi to150 psiMaximum Water Temperature 1800FFactory pre-set 50 psiStandard Thread Connections (FNPT) ANSI B 1.20.1

STANDARD COMPLIANCEASSE® LISTED 1003IAPMO® LISTEDCSA® LISTED (1/2” thru 11⁄4”)CITY OF LOS ANGELES APPROVEDNSF/ANSI 61-2010 CERTIFIED BY IAPMO R&T (1/2” thru 11⁄4”)NSF/ANSI 372

Double Threaded End ConnectionsSimplify installation with pipe size flexibility. Standard models areequipped with one union end connection and male/female threadedconnection on the other valve end. Several different end-connection and sizes are available.

Note: Valve fully open with no spring, for fall of curve consult factory or visit website.Flomatic can accept no responsibility for possible errors in catalogues, brochures and other printed material. Flomatic reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed. All trademarks in this material are property of the respective companies. Flomatic and the Flomatic logotype are trademarks of Flomatic. All rights reserved.

HEAD LOSS CHARTS

Pressure Reducing ValveResidential and Commercial Water Systems

Model C150E

1/2” thru 2”

High capacity globe style design

Unleaded Bronze Body

NSF/ANSI 61-2010 certified by IAPMO R&T

NSF/ANSI 372

Flomatic Corporation 15 Pruyn’s Island Drive

Glens Falls, NY 12801-4421

Telephone: 1-(800)-833-2040 Direct Telephone: 1-(518)-761-9797

Fax: 1-(800)-314-3155 Direct Fax: 1-(518)-761-9798

www.flomatic.com

High Quality Valves Built to Last...Flomatic Valves

© Copyright 2014 by Flomatic #Y150E Rev. 2/14

UNLEADED VALVES

UNLEADED VALVES

Flomatic ValvesHigh Quality Valves Built to Last...

One of the lowest flow losses in the industry

High Quality Valves Built to Last…

27595 C150E_C150E 3/27/14 8:37 AM Page 1