FOX DA8 Plus • Setup GuideThis guide provides quick start instructions for an experienced installer to set up and operate the Extron FOX DA8 Plus fiber optic distribution amplifier. See the drawing on the next page.
WARNING: This unit outputs continuous invisible light, which may be harmful to the eyes; use with caution. For additional safety, plug the attached dust caps into the optical transceivers when the fiber optic cable is unplugged.
InstallationStep 1 — Mounting
Turn off or disconnect the power sources to all equipment and mount the FOX DA8 Plus as desired.
Step 2 — ConfigurationSet the rear panel DA configuration switch to configure the unit as either one 8-output DA, two 4-output DAs, or four 2-output DAs. See the drawing below.
FOX DA8 Plus100-240V 0.3A
OPTICAL OUTPUTS
A B C D
OUT IN1
OUT IN3
OUT IN5
OUT IN7
(1)1
x8(2
)1x4
(4)1
x2
50/60 Hz
RS-232
Tx Rx
OUT N/A4
OUT N/A6
OUT N/A 8
OUT N/A2
FOX DA8 Plus100-240V 0.3A
OPTICAL OUTPUTS
A B C D
OUT IN1
OUT IN3
OUT IN5
OUT IN7
(1)1
x8(2
)1x4
(4)1
x2
50/60 Hz
RS-232
Tx Rx
OUT N/A4
OUT N/A6
OUT N/A 8
OUT N/A2
FOX DA8 Plus100-240V 0.3A
OPTICAL OUTPUTS
A B C D
OUT IN1
OUT IN3
OUT IN5
OUT IN7
(1)1
x8(2
)1x4
(4)1
x2
50/60 Hz
RS-232
Tx Rx
OUT N/A4
OUT N/A6
OUT N/A 8
OUT N/A2
Rx
Tx Tx Tx Tx TxTx Tx
Rx Rx Rx Rx Rx Rx Rx Rx Rx Rx Rx Rx Rx Rx Rx Rx Rx Rx Rx Rx Rx Rx RxCGroup: A Group: A C DB
One 8-output DA Two 4-output DAs(Groups A and C)
Four 2-output DAs(Groups A through D)
(1)1
x8(2
)1x4
(4)1
x2
(1)1
x8(2
)1x4
(4)1
x2
(1)1
x8(2
)1x4
(4)1
x2Step 3 — Optical Inputs
OPTICAL2* 1
LIN
K
LIN
K
OPTICAL1 2*
* OPTIONAL FOR RETURN DATA
LIN
K
LIN
K
Transmitter
Receiver
DA
3
4A
OUT IN1
Connect a fiber optic transmitter (or the maximum number of inputs as determined by the DA configuration switch position in step 2) to the FOX DA8 Plus rear panel input connector.
NOTES: • Inputs 3, 5, and 7 (the right-hand connector on those transceiver blocks) are functional only when selected as an input using the DA configuration switch.
• The right-hand connector for transceiver blocks 2, 4, 6, and 8 can never be functional. • Singlemode and multimode devices are not interchangeable. Ensure that you connect transmitting and
receiving devices that are compatible with the FOX DA8 Plus. • Ensure that you use the proper fiber cable for your system. Typically, singlemode fiber has a yellow jacket
and multimode cable has an orange or aqua jacket.
Step 4 — Optical OutputsConnect up to eight fiber cables between the FOX DA Output LC connectors (the left-hand connector on each transceiver block) and compatible receivers.
Step 5 — Remote Control Connections
Do not tin the wires!
ControllingDevice
Gnd ( )RxTx
Ground ( )Receive (Rx)Transmit (Tx)
Bidirectional
RS-232
Tx Rx
FunctionPinTXRXGnd
Transmit dataReceive dataSignal ground
z Connect a host device to the rear panel RS-232 port. See the drawing at right to make the connection
z Connect a host device to the front panel Config(uration) port, a mini USB port.
Step 6 — PowerUse a standard IEC power cord to connect the FOX DA8 Plus power connector and a 100 VAC to 240 VAC, 50-60 Hz power source.
2
FOX DA8 Plus
100-240V 0.3A
50/60 Hz
OPTICAL OUTPUTS
A
OUTIN1
OUTN/A2
B
OUTIN3
OUTN/A4
C
OUTIN5
OUTN/A6
D
OUTIN7
OUTN/A8 (1
)1x8
(2)1
x4(4
)1x2
N15779
RS-232
Tx Rx
FOX 500 Tx
100-240V 0.3A
50/60 Hz
AUDIO INPUTS
INPUT LOOP THRU
RGB INPUT
R
G
B
H
V
OR
L
R
RS-232
PASS THRU
Tx RxNA
RS-232
CONTROLALARM
* OPTIONAL FOR
RETURN DATA
LIN
K
LIN
K
Tx Rx1 2
RGB
OPTICAL
12*
FOX 500 Rx
AUDIO OUTPUT
RGB OUTPUTS
R
G
B
H
V
L
R
RS-232
PASS THRU
Tx RxNA
RS-232
CONTROLALARM
12*
* OPTIONAL FOR
RETURN DATALI
NK
LIN
K
Tx Rx1 2
RGB
100-240V 0.3A
50/60 Hz
OPTICAL
FOX 500 Rx
AUDIO OUTPUT
RGB OUTPUTS
R
G
B
H
V
L
R
RS-232
PASS THRU
Tx RxNA
RS-232
CONTROLALARM
12*
* OPTIONAL FOR
RETURN DATA
LIN
K
LIN
K
Tx Rx1 2
RGB
100-240V 0.3A
50/60 Hz
OPTICAL
POWER
12V
3A MAX
OUTPUT4/8
OHMS
INPUTS
L
R
L
R
REMOTE
VOL/MUTE
10V50mA
L
MPA 152
R
C
US
LISTED
17TT
AUDIO/VIDEO
APPARATUS
CLASS 2 WIRING
DO NOT GROUND
OR SHORT
SPEAKER OUTPUTS!
ExtronFOX 500 DVI RxFiber Optic Receiver
ExtronFOX 500 DVIFiber Optic Receiver
Projector
Projector
Flat Panel Display
Flat Panel Display
DVI Output
DVI Output
RGB Output
RGB Output
RGB Input
ExtronFOX 500 TxFiber Optic Transmitter
ExtronFOX DA8 PlusFiber Optic Distribution Amplifer
Audio Input
PC
LocalMonitor
ExtronFOX 500 RxFiber Optic Receiver
ExtronFOX 500 RxFiber Optic Receiver
ExtronMPA 152Mini Power Ampli�er
ExtronSI 26XTwo-way CeilingSpeakers
Selected SIS CommandsThe table below is a partial list of SIS commands the you can use to mute outputs and configure the input reclockers. For a complete listing, see the FOX DA8 Plus User Guide. Run the commands from a PC connected to the RS-232 port or the Configuration (USB) port.
Command ASCII Command (Host to Unit)
Response (Unit to Host)
Additional Information
Mute or unmute one output X!*X@B VmtX!*X@] X! = output, X@ = 0 (mute off) or 1 (mute on).Show mute status of an output X!*B X@] X! = output, X@ = 0 (mute off) or 1 (mute on).Mute or unmute all outputs X@*B VmtX@] X@ = 0 (mute off) or 1 (mute on).Set input reclocker mode X#*X$= RteX#*X$] X# = 00 (all inputs), 01, 03, 05, or 07.
X$ = 00 (bypass), 01 (1.25 Gbps), 02 (2.125 Gbps), or 03 (4.25 Gbps).Show reclocker mode X#= X$] X# and X$ are the same as for “Set input reclocker mode” command.
] = Carriage return and line feed • = space
68-2145-50 Rev A 07 11
Extron USA - WestHeadquarters
+800.633.9876Inside USA/Canada Only
+1.714.491.1500+1.714.491.1517 FAX
Extron USA - East
+800.633.9876Inside USA/Canada Only
+1.919.863.1794+1.919.863.1797 FAX
Extron Europe
+800.3987.6673Inside Europe Only
+31.33.453.4040+31.33.453.4050 FAX
Extron Asia
+800.7339.8766Inside Asia Only
+65.6383.4400+65.6383.4664 FAX
Extron Japan
+81.3.3511.7655+81.3.3511.7656 FAX
Extron China
+400.883.1568Inside China Only
+86.21.3760.1568+86.21.3760.1566 FAX
Extron Middle East
+971.4.2991800+971.4.2991880 FAX
© 2011 Extron Electronics. All rights reserved. www.extron.com
FOX DA8 Plus • Setup Guide (Continued)