gas-pro - cebeco

52
V1 © Copyright All Rights Reserved Crowcon Detection Instruments Ltd. Gas-Pro 1 Presented by: Nick Dajda Date:

Upload: others

Post on 23-Apr-2022

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Gas-Pro - Cebeco

V1

© Copyright All Rights Reserved Crowcon Detection Instruments Ltd.

Gas-Pro

1

Presented by: Nick Dajda Date:

Page 2: Gas-Pro - Cebeco

V1

© Copyright All Rights Reserved Crowcon Detection Instruments Ltd.

Contents

Product positioning Features and benefits Familiarisation Markets & competition Product structure Summary Gas-Pro PID I-Test

2

Page 3: Gas-Pro - Cebeco

V1

© Copyright All Rights Reserved Crowcon Detection Instruments Ltd.

Crowcon Portables Product Range

3

Price

Clip Low cost

disposable single gas

Gasman Single gas

Great choice of sensors

Triple Plus+ Rugged and trusted

Detective+ Temporary area

monitoring

Tetra 3 Specialist multigas

Gas-Pro Highly configurable 5 gas pumped

Wide range of applications

Tetra Specialist

pumped multigas

Func

tiona

lity

T4 Everyday multigas

Page 4: Gas-Pro - Cebeco

V1

© Copyright All Rights Reserved Crowcon Detection Instruments Ltd.

Crowcon Gas-Pro

4

5-gas

Pumped

VOC Flam/CO2 IR

Pre-entry checking

Specialist, pumped 5-gas with impressive range of sensors

Page 5: Gas-Pro - Cebeco

V1

© Copyright All Rights Reserved Crowcon Detection Instruments Ltd.

FEATURES Gas-Pro Product Introduction

5

Page 6: Gas-Pro - Cebeco

V1

© Copyright All Rights Reserved Crowcon Detection Instruments Ltd.

Introduction Gas-Pro Overview

• Measure up to 5 gases • Optional pump up to 30 metre (100 feet) sampling • Pre-Entry Check function • +ve Safety for full unit compliance • Full data/event logging for record keeping • User definable, set up to site requirements • Robust unit for harsh environments IP65 & IP67* • One button for ease of use • Top mount display for quick decision making • Multiple charging options • Easy test solutions for bump and calibration

*IP66 PID Unit

6

Page 7: Gas-Pro - Cebeco

V1

© Copyright All Rights Reserved Crowcon Detection Instruments Ltd.

Gas-Pro Overview Capabilities

• Oxygen • Toxic (Electrochemical) • Flammable (Pellistor) • Flammable (IR) • Carbon dioxide (IR) • VOC (PID)

• Flammable Calibrations:

7

Page 8: Gas-Pro - Cebeco

V1

© Copyright All Rights Reserved Crowcon Detection Instruments Ltd.

Features Features Benefits Top mount display Easily viewed without having to handle the detector

Dual colour backlight

Backlit green when the operator button is pressed Backlit red when in alarm. Instant recognition of danger, and highlights gas in alarm.

Integral over mould anti-shock case

Withstand environmental and usage demands. Case material is anti-static and resistant to corrosive elements found in target markets. Gives shock resistance removing the need for extra rubber boots.

+ve Safety Immediate recognition of detector status in the field or on return from site. No need to handle the detector to ensure it is compliant & safe.

Wide sensor capability

Ensures the right gas detection for target markets using a wide range of sensing technologies. The flexibility to cater for a wide range of requirements.

Internal pump (option)

Pre-entry testing can be performed with the same unit as worn for entries. Automatic flow plate recognition ensures safety and makes usage easy, whilst removing the need to have to charge a separate pump.

8

Page 9: Gas-Pro - Cebeco

V1

© Copyright All Rights Reserved Crowcon Detection Instruments Ltd.

Features Features Benefits

Optimally sized Compact solution that will not hinder the primary purpose, whilst being large enough to be usable whilst wearing gloves and strong to withstand continuous use.

Li-ion battery High capacity cell giving >19hrs runtime (CH4, O2, CO, H2S) and fast re-charge (<5 hrs). No need to hunt around for replacement cells, charge in-vehicle, in office or during test and calibration.

Data and event logging as standard

Ensure understanding of alarm and event data by monitoring not only the event but the data surrounding it. Monitor gas test frequency and review

Audible, visual and vibrate alarms

With >95dB at 30cm (1ft), dual red/blue visual alarm, red backlight and in-case vibrate alert ensure the user is notified of danger.

Pre-Entry Check (PEC) mode

Guides user through PEC and registers as an event in the datalog. Allows the user to demonstrate that correct procedure was followed and gives the safety manager/supervisor the ability to review readings.

Highly visible case Instantly recognise that crews are wearing their detector – the bright orange case naturally stands out from clothing when worn.

9

Page 10: Gas-Pro - Cebeco

V1

© Copyright All Rights Reserved Crowcon Detection Instruments Ltd.

Features Features Benefits User changeable sound level

For quiet or loud applications, ensures confidence blip and alarms are heard.

Bump / Pump functionality

Quick and simple recognition of sensor coverage – does not allow users to place a flow plate over the sensors without having to acknowledge the action

10

Page 11: Gas-Pro - Cebeco

V1

© Copyright All Rights Reserved Crowcon Detection Instruments Ltd.

+ve Safety Comprehensive status indication for the user, and others nearby

o Calibration o Bump test o Battery o Sensor over range o Recent alarm o TWA o Unit fault

11

Page 12: Gas-Pro - Cebeco

V1

© Copyright All Rights Reserved Crowcon Detection Instruments Ltd.

+ve Safety Comprehensive status indication

GREEN - Flashing Detector is compliant to the site or user specific requirements as set within the configuration. AMBER – Double Flash Detector is operational but requires attention. One or more of the pre-set flags has been triggered to change the status. RED - Constant flash Indicates the detector is not within the specified criteria for use and should not be used.

12

Page 13: Gas-Pro - Cebeco

V1

© Copyright All Rights Reserved Crowcon Detection Instruments Ltd.

+ve Safety

Area Standard Classic Enhanced Sensors calibrated Not Monitored Not Monitored

Sensors bump tested Not Monitored Not Monitored

Sensor out of bump period Not Monitored Not Monitored

Sensor out of calibration Not Monitored Not Monitored

No 1st level alarms Not Monitored No 2nd level alarms Not Monitored Recent alarm Not Monitored Not Monitored

Sensor over range Not Monitored Not Monitored

TWA alarm exceeded Not Monitored Not Monitored

Detector fault Not in fault Not Monitored

The LED can be configured off, Green flashing or Green on

13

Page 14: Gas-Pro - Cebeco

V1

© Copyright All Rights Reserved Crowcon Detection Instruments Ltd.

Flow plate • Gas-Pro recognises when a flow plate has been introduced • If this is a pumped detector, it will enter a bump/pump screen:

14

Press to cycle / double press to select

Page 15: Gas-Pro - Cebeco

V1

© Copyright All Rights Reserved Crowcon Detection Instruments Ltd.

Pump mode

• Pump Test runs when the pump is activated to check for leaks in the sample line o Cover the inlet o Gas-Pro checks pump current draw o If test fails: remove the flow plate, check the gasket and connection

to sample line

• If the flow plate is attached at switch on, Pump Test will be activated during start-up.

15

Page 16: Gas-Pro - Cebeco

V1

© Copyright All Rights Reserved Crowcon Detection Instruments Ltd.

Bump mode

• Once ‘bump mode’ is activated the Gas-Pro is ready to commence bump testing.

• This will only take place if the detector is configured to do so • If a bump test is failed, a calibration can be done, if the detector

is configured to do so • The detector can hold 2 groups of gases

Scenarios: o CO/H2S/LEL/O2 as group 1, and CO2 as group 2 o LEL as group 1 (for daily ATEX bump) and CO/H2S/O2 for group 2

(saving gas)

16

Page 17: Gas-Pro - Cebeco

V1

© Copyright All Rights Reserved Crowcon Detection Instruments Ltd.

Bump testing and flow plates

17

Bump Test: Bump enabled Bump disabled

Flow plate not attached

Pump and bump icons do not appear in menu when no flow plate attached

When flow plate

attached

Pump or bump menu automatically displayed.

Double click on pump to begin sampling, or single click to select bump , double

click to commence bump test

Gas-Pro will automatically begin pumped mode

During pumped

operation

Additional option appears in the menu:

Selecting to switch off pump and begin a bump test

No bump test option available in menu

Pump or bump menu:

Page 18: Gas-Pro - Cebeco

V1

© Copyright All Rights Reserved Crowcon Detection Instruments Ltd.

Pre-Entry Check (PEC) mode

Confirm

Sampling phase Real time levels displayed

Peak phase Peak gas levels displayed

Purge phase For clearing sample line

Double press or wait 5 mins

Double press or wait 5 mins

18

Page 19: Gas-Pro - Cebeco

V1

© Copyright All Rights Reserved Crowcon Detection Instruments Ltd.

• The user is not in the presence of the gas being measured User safety

• PEC does not include levels detected in any TWA calculations Keeping workers working, reducing the instance of TWA alarm.

• PEC will also show on the log

Audit trail showing procedure was completed, and for reporting the peak levels

• PEC takes user through sampling, peak and purge process

Helps ensure user performs a thorough gas check of the confined space, and clears sample line prior to entry

Pre-Entry Check (PEC) mode

19

Page 20: Gas-Pro - Cebeco

V1

© Copyright All Rights Reserved Crowcon Detection Instruments Ltd.

FAMILIARISATION Gas-Pro Product Introduction

20

Page 21: Gas-Pro - Cebeco

V1

© Copyright All Rights Reserved Crowcon Detection Instruments Ltd.

Orientation - Front

• Clear top mount display with dual colour backlight

• +ve Safety™ tri-colour status indicator

• Pump inlet and outlet (pumped only) • Front, top and side visible alarm

windows • Four sensor apertures • Large resonant sound cavity for ultra-

loud audible alarm • Single operator button • Integral over mould anti-shock case

Gas-Pro Overview

21

Page 22: Gas-Pro - Cebeco

V1

© Copyright All Rights Reserved Crowcon Detection Instruments Ltd.

Orientation - Back

• Alligator pocket clip • D-Ring for drop line attachment • Certification label • Charging and communication

socket for interface with I-Test manager or Portables Pro Software

Gas-Pro Overview

22

Page 23: Gas-Pro - Cebeco

V1

© Copyright All Rights Reserved Crowcon Detection Instruments Ltd.

Quick View

• A momentary press of the operator (until 1 blip) button allows insight into the Gas-Pro status and settings o Gas type and units o Battery status o Unit/User ID (24 characters) o +ve Safety™ status

23

Page 24: Gas-Pro - Cebeco

V1

© Copyright All Rights Reserved Crowcon Detection Instruments Ltd.

Charging

• Gas-Pro is available with a range of application suited charging options

o Power only with multi-region supply o Vehicle charging o Power and communication via USB

• These options can either be used on their own, or in conjunction with the Gas-Pro cradle

• Gas-Pro indicates the current charge status and when charging is being applied. o Charging when off is indicated by a filling battery in the centre of the

screen and is accompanied by an LED indicating red for charging. o Charging when on is indicated by a filling battery at the base of the

screen on the left.

24

Page 25: Gas-Pro - Cebeco

V1

© Copyright All Rights Reserved Crowcon Detection Instruments Ltd.

Charging

• Simply and quickly the relevant charging or communication lead can be inserted into the cradle

• The cradle can be mounted in 4 ways o Vertical on a wall or desk o Horizontal on a wall or desk

• The USB communications cable can also be used with the cradle, but will not deliver power to the Gas-Pro.

25

Page 26: Gas-Pro - Cebeco

V1

© Copyright All Rights Reserved Crowcon Detection Instruments Ltd.

Power up

• By pressing the operator button for 3 seconds Gas-Pro enters start-up o Product screen (serial number, s/w versions, product name and

Crowcon) o Screen is tested (horizontally and vertically) o Splash screen (1st is Crowcon, 2nd can be customised or not used) o Current settings (pump, sound level, user ID) o Bump (last completed and next due, also shows current date) o Calibration (last completed and next due, also shows current date) o Pump test (if pumped and flow plate is on) o Zero (auto zero count down, sensor status) o Home screen

27

Page 27: Gas-Pro - Cebeco

V1

© Copyright All Rights Reserved Crowcon Detection Instruments Ltd.

In operation

• Home screen o Gases and units o Gas levels o Battery status o Pump icon o Home screen

28

Page 28: Gas-Pro - Cebeco

V1

© Copyright All Rights Reserved Crowcon Detection Instruments Ltd.

Alarms

• In alarm, the back light turns from green to red, and the gas in alarm inverts

• The dual red/blue LED’s alternate • The 95dB alarm sounds • The Gas-Pro vibrates

29

Page 29: Gas-Pro - Cebeco

V1

© Copyright All Rights Reserved Crowcon Detection Instruments Ltd.

Menu functions

• Home • Zero • TWA • PEC • Peak review • User settings

30

Page 30: Gas-Pro - Cebeco

V1

© Copyright All Rights Reserved Crowcon Detection Instruments Ltd.

Applications

32

Gas-Pro Confined space entry:

o Construction o Marine o Water / Utilities o Chemical industry o Agriculture

Common 5-gas (O2, CO, H2S, Flam, CO2)

o Waste water, utilities o Construction o Oil & gas

Specialist gases o Chlorine (water treatment) o Ammonia (refrigeration,

agriculture, …)

Gas-Pro IR CO2 detection:

o Breweries, wineries o Beverage delivery o Agriculture

(greenhouses) o Food industry o Chemical industry

IR flam detection: o Oil & gas o Inert atmospheres

Gas-Pro PID ppm level flammables:

o Security o Jet fuel detection o Oil & gas

Solvents o Chemical industry o Pharmaceutical o Shipping

Page 31: Gas-Pro - Cebeco

V1

© Copyright All Rights Reserved Crowcon Detection Instruments Ltd.

CO2 IR

34

So: 1) Gas-Pro will display ~0.04 %vol in background CO2 levels

2) Do not breathe near Gas-Pro when zeroing CO2 sensor

Background CO2 in the atmosphere: CO2 typically exhaled:

~ 4% (40,000 ppm)

Page 32: Gas-Pro - Cebeco

V1

© Copyright All Rights Reserved Crowcon Detection Instruments Ltd.

PRODUCT STRUCTURE Gas-Pro Product Introduction

38

Page 33: Gas-Pro - Cebeco

V1

© Copyright All Rights Reserved Crowcon Detection Instruments Ltd.

Gas-Pro Overview Capabilities

39

Compounds Sensor type Gases

Oxygen O2

Toxic Electrochemical NH3, SO2, O3, Cl2, ClO2, NO, NO2, CO, H2S

Flammable Pellistor %LEL flam

Flammable IR %LEL flam

Carbon dioxide IR 0-5% vol CO2

VOC PID Benzene, Jet fuel, …

Page 34: Gas-Pro - Cebeco

V1

© Copyright All Rights Reserved Crowcon Detection Instruments Ltd.

Product configurator

41

Gas-Pro page on crowcon.com:

Page 35: Gas-Pro - Cebeco

V1

© Copyright All Rights Reserved Crowcon Detection Instruments Ltd.

Support materials

Product Q&A Price list – for configurations Gas-Pro product web pages:

Brochures User manuals Specifications Gas-Pro usage videos

42

Gas-Pro Q&A

Page 36: Gas-Pro - Cebeco

V1

© Copyright All Rights Reserved Crowcon Detection Instruments Ltd.

In the box

43

• Gas-Pro monitor

• Multilingual CD manual

• Multilingual quick start guide

• Packing check list (printed label)

• Calibration report including configuration detail

Page 37: Gas-Pro - Cebeco

V1

© Copyright All Rights Reserved Crowcon Detection Instruments Ltd.

GAS-PRO PID Gas-Pro Product Introduction

44

Page 38: Gas-Pro - Cebeco

V1

© Copyright All Rights Reserved Crowcon Detection Instruments Ltd.

• Gas-Pro PID is IP 66 due to no filter being in place over the PID sensor

• PID sensors should not be fitted with any filters, this slows response times

Gas-Pro PID Overview VOC detection

45

Page 39: Gas-Pro - Cebeco

V1

© Copyright All Rights Reserved Crowcon Detection Instruments Ltd.

Gas-Pro PID Applications

Measuring Solvent, Fuel, glues and VOC vapors in the workplace environment

Applications

46

Page 40: Gas-Pro - Cebeco

V1

© Copyright All Rights Reserved Crowcon Detection Instruments Ltd.

Applications

VOCs are organic compounds characterized by tendency to evaporate easily at room temperature Familiar VOCs include: Solvent Paint thinner Nail polish remover Gasoline Diesel Heating oil Kerosene

Jet fuel Benzene Hexane Toluene Xylene Butadiene

Volatile organic compounds (VOCs)

47

Page 41: Gas-Pro - Cebeco

V1

© Copyright All Rights Reserved Crowcon Detection Instruments Ltd.

VOC response factors PID Ionisation Potential

49

Page 42: Gas-Pro - Cebeco

V1

© Copyright All Rights Reserved Crowcon Detection Instruments Ltd.

Things to know with PID PID considerations

• Gas-Pro PID will detect other VOC’s if present, not species specific

• Gas-Pro PID lamps need cleaning on a regular basis, we provide a cleaning kit (C03664) and we have a written procedure – document PID-AN-001

• The sensor has a warranty of 1 year and will have a operating period of 10,000 hours.

• If the PID fails the first thing to change is the Electrode Stack this the most likely failure point, followed by the lamp

50

Page 43: Gas-Pro - Cebeco

V1

© Copyright All Rights Reserved Crowcon Detection Instruments Ltd.

Things to know with PID Gas-Pro PID Considerations • Measuring Range – 0-1000 PPM (0.1 PPM increments) • PID response time in pump mode – T90 - 40 Seconds • PID response time in diffusion mode – T90 - 52 Seconds • Based on response to Isobutylene at standard temperature and

pressure • Lamp is filled with Krypton, we use a 10.6eV lamp. If this lamp

is dropped and damaged the gas is released and this is needed for the sensor to work.

51

Page 44: Gas-Pro - Cebeco

V1

© Copyright All Rights Reserved Crowcon Detection Instruments Ltd.

Q-TEST, I-TEST Gas-Pro Product Introduction

52

Page 45: Gas-Pro - Cebeco

V1

© Copyright All Rights Reserved Crowcon Detection Instruments Ltd.

Q-Test

• Quick and simple in-field test and calibration

• Unpowered solution for off-site testing • Simple to use and set up • Power enabled Q-Test also offers the ability

to charge • Single gas inlet and exhaust • Suitable for gas mixes (tri, quad, quin)

53

Page 46: Gas-Pro - Cebeco

V1

© Copyright All Rights Reserved Crowcon Detection Instruments Ltd.

Q-Test operation

• Closing the door activates the bump/pump mode (if pumped). • The user selects the correct function then controls the gas to

perform the required test. • Once the detector has passed (or failed) the test, the user turns

off the gas. • The detector is now ready for use.

55

Page 47: Gas-Pro - Cebeco

V1

© Copyright All Rights Reserved Crowcon Detection Instruments Ltd.

Crowcon’s I-Test I-Test

• Full calibration • Full bump testing • Data management • Easy to use • Ability to update unit configs • Charging of units • Battery or mains powered • Software to support (I-Test Manager) • Stores and updates bump/calibration records. • No computer required for calibration/bump test. • Entirely self contained. • Gas cylinder management

56

Page 49: Gas-Pro - Cebeco

V1

© Copyright All Rights Reserved Crowcon Detection Instruments Ltd.

Calibration Gas Control Cylinder tracking

• Using the software allows the user to define a cylinder for storage in the database

• A user can enter the cylinder themselves • User can upload a pre-saved cylinder • Cylinder levels must be set • A gas can be removed and added to a cylinder definition list • Able to give a description to the cylinder • Choose test type, for example Speedy bump which allows

quicker Bump tests and saves on cost of gas

58

Page 50: Gas-Pro - Cebeco

V1

© Copyright All Rights Reserved Crowcon Detection Instruments Ltd.

Crowcon’s I-Test I-Test manager

The software offers great flexibility: o Change alarm levels on each sensor o Control calibration gas and lot numbers o Set up inlets with the correct gas o Set up banners on the display o Set calibration information and store results o Set bump test information and store results o View event and data logs and run reports o Print and calibration/bump certificates

And more to allow site specific requirements to be reflected

59

Page 51: Gas-Pro - Cebeco

V1

© Copyright All Rights Reserved Crowcon Detection Instruments Ltd.

Crowcon’s I-Test Applications

Customers that have a wide area to cover, such as: • Oil/Steel Refineries

• Fire and Hazmat teams

• Utilities Markets

• Distribution

• Shipping and repair centres

• Upstream and down stream oil and gas

60

Page 52: Gas-Pro - Cebeco

V1

© Copyright All Rights Reserved Crowcon Detection Instruments Ltd.

I-Test In the box... • I-Test either ATEX or UL • Multi regional power supply • 2 x quick connects • 1 x 1m tubing for cal/bump gas • 1 x 3m tubing for exhaust • 1 x USB for data download • Wall bracket and screws • 1 x CD manual • 1 x quick start guide

Also required • Demand flow regulator • Cal/bump gas required • Wall holder for gas

61