gss-katalog-scup-scu-scp-sc-0 modular multis… · nshq 5t\jw xzuuq^ 85 ] ] rr nshq 5t\jw xzuuq^ 85...

6
Modular Multiswitch System 5 YEARS WARRANTY ready

Upload: others

Post on 13-Jun-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: GSS-KATALOG-SCUP-SCU-SCP-SC-0 Modular Multis… · nshq 5t\jw xzuuq^ 85 ] ] rr nshq 5t\jw xzuuq^ 85 )nrjsxntsx \nym rtzsynsl kjjy < ] - ] ) ] ] rr nshq 5t\jw xzuuq^ 85 ] ] rr nshq

Modular Multiswitch System

5YEARS

WARRANTY

ready

Page 2: GSS-KATALOG-SCUP-SCU-SCP-SC-0 Modular Multis… · nshq 5t\jw xzuuq^ 85 ] ] rr nshq 5t\jw xzuuq^ 85 )nrjsxntsx \nym rtzsynsl kjjy < ] - ] ) ] ] rr nshq 5t\jw xzuuq^ 85 ] ] rr nshq

SCUP 524.1 SCUP 516.1CASCADABLEUNICABLEMULTISWITCH

UNICABLEMULTISWITCH

• Programmable dCSSmultiswitch• Unicable solution for• up to 24 users• 5 inputs (4 x SAT/1 x TER.)• Expandable plug system• Universally expandable• Robust cast housing•

Prefix for GSS.compact• and GSS.lamina5 inputs (4 x SAT/1 x TER.)• Extension of the SAT inputs• Robust cast housing•

SCP 508

• 5 inputs (4 x SAT/1 x TER.)8 user outputs• Expandable plug system• Universally expandable• Suitable for Quad LNB• Robust cast housing•

CASCADABLEMULTISWITCH

CASCADABLEMULTISWITCH

SC 508

• 5 inputs (4 x SAT/1 x TER.)8 user outputs• Expandable plug system• Universally expandable• Robust cast housing•

• 5 inputs (4 x SAT/1 x TER.)4 user outputs• Expandable plug system• Universally expandable• Robust cast housing•

• 18 V DC power supply1200 mA•

BASIC UNIT BASIC UNIT

SCU 524.1CASCADABLEUNICABLEMULTISWITCH

PROGRAMMIERERFÜR SCU/SCUP 524.1

SCUPROGRAMMER

• Programmable dCSSmultiswitch• Unicable solution for up• to 24 users• 5 inputs (4 x SAT/1 x TER.)• Expandable plug system• Universally expandable• Robust cast housing•

• Programming tool fordCSS multiswitches• F / USB connection• incl. 12 V power• supply unit, USB cable• and program software•

EXTENSION UNIT ZUBEHÖR

CASCADABLEMULTISWITCH

SP 1812

POWER SUPPLY UNIT

SC 504CASCADABLEMULTISWITCH

EXTENSION UNIT

EXTENSION UNITBASIC UNIT

Page 3: GSS-KATALOG-SCUP-SCU-SCP-SC-0 Modular Multis… · nshq 5t\jw xzuuq^ 85 ] ] rr nshq 5t\jw xzuuq^ 85 )nrjsxntsx \nym rtzsynsl kjjy < ] - ] ) ] ] rr nshq 5t\jw xzuuq^ 85 ] ] rr nshq

Modular Multiswitch System SCP 508 – SC 508 – SC 504

Basic unit SCP 508 with 5 inputs and 8 outputs incl. flanged power supply unitExtension unit SC 508 with 5 inputs and 8 outputsExtension unit SC 504 with 5 inputs and 4 outputsSystem expandable to up to 32 outputsVariants 5 to 8, 5 to 12, 5 to 16, 5 to 20, 5 to 24, 5 to 28 and 5 to 32 configurableIntegrated 22 kHz signal to use Quad LNBsTerrestrial input is activeReturn-path is passive

Cascade Adapter SC-A

With the cascade adapter, the SC 504 and SC 508 extensionunits can be used as cascade switch over several house floors.

UNIVERSALLYEXPANDABLE

Page 4: GSS-KATALOG-SCUP-SCU-SCP-SC-0 Modular Multis… · nshq 5t\jw xzuuq^ 85 ] ] rr nshq 5t\jw xzuuq^ 85 )nrjsxntsx \nym rtzsynsl kjjy < ] - ] ) ] ] rr nshq 5t\jw xzuuq^ 85 ] ] rr nshq

Typ/Type SCP 508 SC 508 SC 504

No. of Inputs SAT/IF 4 (F) 4 (F) 4 (F)

Terr. 1 (F) 1 (F) 1 (F)

Receiver / Subscriber outputs 8 (F) 8 (F) 4 (F)

Terr. Amplifier 88-790 MHz • - - IF Amplifier 950-2150 MHz • - • Return path passive 5-65 MHz • • • Selection LNB /Polarity

Frequency Range SAT/IF 950 -2150 MHz 950 -2150 MHz 950 -2150 MHz

Terr. 47 - 790 MHz 47 - 790 MHz 47 - 790 MHz

Return path 5-65 MHz 5-65 MHz 5-65 MHz

Insertion-Loss Subscriber outputs SAT/IF @ 950 MHz 0 dB 0 dB 0 dB

all values are within a tolerance of +/- 1.5 dB SAT/IF @ 2150 MHz + 4 dB (upslope) + 4 dB (upslope) + 4 dB (upslope)

Terr.Rec./ Out 1-8 - 2 dB - 24 dB -Terr.Rec./ Out 1-4 - - - 17 dB

Return path / Out 1-8 -23 dB - 23 dB -Return path / Out 1-4 - - - 15 dB

Through-Loss SAT/IF 950 / 2150 MHz - 0.5 dB / -1.5 dB - 0.5 dB / -1.5 dB - 0.5 dB / -1.0 dB

Terr. 88 / 790MHz + 17 / +21 dB - 1.5 dB / -2 dB - 1.5 dB / -2 dB

Return path - 2 dB - 2 dB - 2 dB

Max. Input level SAT/IF 95 dBµV 95 dBµV 95 dBµV

Terr. 90 dBµV n.a. n.a.

Max. Output level (EN 50083-3) SAT/IF IMA3 99 dBµV 99 dBµV 99 dBµV

Terr. 87 dBµV n.a. n.a.

Return-Loss Input / Output > 12 dB > 12 dB > 12 dB

(typ. 15 dB) (typ. 15 dB) (typ. 15 dB)

Isolation SAT-SAT > 30 dB > 30 dB > 30 dB

SAT-TV > 35 dB > 35 dB > 35 dB

Screening Immunity

Max. current from receiver 80 mA 20 mA 20 mA

Temp. Range + Usage

Dimensions without mounting feets 138 x 198 x 37 mm (incl. PSU) 138 x 93 x 25 mm 130 x 110 x 25 mm

Dimensions with mounting feets 155 x 198 x 37 mm (incl. PSU) 155 x 93 x 37 mm 130 x 110 x 37 mm

analog 14.5 - 15.5 V DC / analog 22 kHz +/- 4 kHz

88-300 MHz 85 dB / 47-470 MHz 80 dB / 470-1000 MHz 75 dB / > 1000 MHz 55 dB

- 20 … + 60°C / Indoor use only

Technical specifications

SCP 508 SC 508 SC 504

Page 5: GSS-KATALOG-SCUP-SCU-SCP-SC-0 Modular Multis… · nshq 5t\jw xzuuq^ 85 ] ] rr nshq 5t\jw xzuuq^ 85 )nrjsxntsx \nym rtzsynsl kjjy < ] - ] ) ] ] rr nshq 5t\jw xzuuq^ 85 ] ] rr nshq

Expandable Unicable multiswitches SCUP 524.1 – SC 524.1

Programmable Unicable multiswitch1, 2 or 4 satellites (Quattro LNB 1 SAT, Wideband LNB for 2 + 4 SAT)Automatic reading of the configuration data including chip set temperatureUsable in dynamic mode (factory setting) with 24 user bandsPreset to SCR frequencies for user bands 1 – 8Up to 24 German-language ASTRA transponders in static mode for receiving over 200 channelsvia a coaxial cable (comparable to an IF / IF conversion)Compatible EN50494, EN50607 with extension EN50494 + and dHello protocolSupports DiSEqC 1.x and 2.x commandsProgrammable number of user bands, bandwidth, output level (AGC)Mixed operation possible: dynamic and static mode (e.g. 5 user bands dynamic and 19 fixedtransponders in static mode)Compatible with the multiswitch system SCP 508 / SC 508 / SC 504 (with Quattro LNB only!)To supplement Legacy outputs

OPERATION WITH A QUATTRO LNB

1QUATTRO

LNB

1Satellite

OPERATION WITH 2 WIDEBAND LNBS

24 user bands in Dynamic mode

or

34 transponders in Static mode

2WIDEBAND

LNBs

2Satellites

24 user bands in Dynamic mode

or

34 transponders in Static mode

OPERATION WITH 4 WIDEBAND LNBS

4WIDEBAND

LNBs

4Satellites 1 2

Loop through outputs / power supply

T V LOW H V HIGH H

T V LOW H V HIGH

OUT

1 2

Loop through outputs / power supply

T V LOW H V HIGH H

T V LOW H V HIGH

OUT

1

Loop through outputs / power supply

T V LOW H V HIGH H

T V LOW H V HIGH

OUT

1 2

Loop through outputs / power supply

T V LOW H V HIGH H

T V LOW H V HIGH

OUT

UNIVERSALLYEXPANDABLE

24 user bands in Dynamic mode

or

34 transponders in Static mode

Page 6: GSS-KATALOG-SCUP-SCU-SCP-SC-0 Modular Multis… · nshq 5t\jw xzuuq^ 85 ] ] rr nshq 5t\jw xzuuq^ 85 )nrjsxntsx \nym rtzsynsl kjjy < ] - ] ) ] ] rr nshq 5t\jw xzuuq^ 85 ] ] rr nshq

Typ/Type SCU 524.1 - EXTENSION UNIT without Power supply

No. of Inputs Sat/IF 4 x IF input from Quattro-LNB or 2 Wideband TWIN-LNBs

Terr. 1 x UHF / VHF input for terrestrial antenna

Receiver outputs Sat 4 x IF cascade outputs

Terr. 1 x Terrestrial cascade output

dCSS 1x dCSS-Output (EN50607) dynamic mode

max. 24 User bands and combined terrestrial signal

Protokoll DiSEqC1.x/DiSEqC2.0, EN50494/EN50494+/EN50607

Input Frequency Range Sat (Quattro-LNB): 950-2150 MHz (default)

Wideband LNB: 300-2350 MHz

Terr.: 5-790 MHz

Insertion loss subscriber output: Sat /Terr.: 3 dB max. / 10 dB max.

Max. Level INPUT Sat /Terr.: -25 dBm / -15 dBm

Max. Level Output Sat: -22 dBm (AGC)

Isolation IF Inputs 25 dB min.

User Band Configurable, 10-80 MHz (default 30 MHz)

Power -

-

Temparature range -15°C …. + 60°C

Dimensions without mounting feet (W x H x D) 138 x 93 x 25 mm

Dimensions with mounting feet (W x H x D) 155 x 93 x 25 mm

Typ/Type SCUP 524.1 - BASIC UNIT incl. POWER SUPPLY SP 1812 SCUP 516.1 - BASIC UNIT incl. POWER SUPPLY SP 1812

No. of Inputs Sat/IF 4 x IF input from Quattro-LNB or 2 Wideband TWIN-LNBs 4 x IF input from Quattro-LNB or 2 Wideband TWIN-LNBs

Terr. 1 x UHF / VHF input for terrestrial antenna 1 x UHF / VHF input for terrestrial antenna

Receiver outputs Sat 4 x IF cascade outputs 4 x IF cascade outputs

Terr. 1 x Terrestrial cascade output 1 x Terrestrial cascade output

dCSS 1x dCSS-Output (EN50607) dynamic mode 1x dCSS-Output (EN50607) dynamic mode

max. 24 User bands and combined terrestrial signal 16 User bands

Protocol DiSEqC1.x/DiSEqC2.0, EN50494/EN50494+/EN50607 DiSEqC1.x/DiSEqC2.0, EN50494/EN50494+/EN50607

Input Frequency Range Sat (Quattro-LNB): 950-2150 MHz (default) 950-2150 MHz (default)

Wideband LNB: 300-2350 MHz 300-2350 MHz

Terr.: 5-790 MHz 5-790 MHz

Insertion loss subscriber output: Sat /Terr.: 3 dB max. / 10 dB max. 3 dB max. / 10 dB max.

Max. Level INPUT Sat /Terr.: -25 dBm / -15 dBm -25 dBm / -15 dBm

Max. Level Output Sat: -22 dBm (AGC) -22 dBm (AGC)

Isolation IF Inputs 25 dB min. 25 dB min.

User Band Configurable, 10-80 MHz (default 30MHz) Configurable, 10-80 MHz (default 30MHz)

Power incl. Power supply incl. Power supply

< 5 Watt (max. 24 User bands active) < 5 Watt (max. 24 User bands active)

Temparature range -15°C …. + 60°C -15°C …. + 60°C

Dimensions without mounting feet (W x H x D) 138 x 198 x 37 mm (incl. Power supply SP 1812) 138 x 198 x 37 mm (incl. Power supply SP 1812)

Dimensions with mounting feet (W x H x D) 155 x 198 x 37 mm (incl. Power supply SP 1812) 155 x 198 x 37 mm (incl. Power supply SP 1812)

Subject to change. Technical information without guarantee. © by GSS Grundig Systems GmbH 03/2018

Technical specifications

Programming for SCUP 524.1 / SCU 524.1 Programming for SCUP 516.1 UB 01: 1284 MHz (EN50494 + EN50607) UB 13: 1104 MHz (EN50607) UB 01: 984 MHz (EN50494 + EN50607) UB 13: 1896 MHz (EN50607)

UB 02: 1400 MHz (EN50494 + EN50607) UB 14: 1140 MHz (EN50607) UB 02: 1056 MHz (EN50494 + EN50607) UB 14: 1968 MHz (EN50607)

UB 03: 1516 MHz (EN50494 + EN50607) UB 15: 1176 MHz (EN50607) UB 03: 1128 MHz (EN50494 + EN50607) UB 15: 2040 MHz (EN50607)

UB 04: 1632 MHz (EN50494 + EN50607) UB 16: 1212 MHz (EN50607) UB 04: 1210 MHz (EN50494 + EN50607) UB 16: 2112 MHz (EN50607)

UB 05: 1748 MHz (EN50494 + EN50607) UB 17: 1248 MHz (EN50607) UB 05: 1292 MHz (EN50494 + EN50607)

UB 06: 1864 MHz (EN50494 + EN50607) UB 18: 1320 MHz (EN50607) UB 06: 1364 MHz (EN50494 + EN50607)

UB 07: 1980 MHz (EN50494 + EN50607) UB 19: 1356 MHz (EN50607) UB 07: 1458 MHz (EN50494 + EN50607)

UB 08: 2096 MHz (EN50494 + EN50607) UB 20: 1436 MHz (EN50607) UB 08: 1530 MHz (EN50494 + EN50607)

UB 09: 960 MHz (EN50494 + EN50607) UB 21: 1472 MHz (EN50607) UB 09: 1602 MHz (EN50494 + EN50607)

UB 10: 996 MHz (EN50494 + EN50607) UB 22: 1552 MHz (EN50607) UB 10: 1680 MHz (EN50494 + EN50607)

UB 11: 1032 MHz (EN50494 + EN50607) UB 23: 1588 MHz (EN50607) UB 11: 1752 MHz (EN50494 + EN50607)

UB 12: 1068 MHz (EN50494 + EN50607) UB 24: 1680 MHz (EN50607) UB 12: 1824 MHz (EN50494 + EN50607)

GSS Grundig Systems GmbHBeuthener Str. 4390471 Nuernberg (Germany)

Phone:Fax:Contact:

+49 (0) 911 703 - 88 77+49 (0) 911 703 - 92 10www.gss.de [email protected]

After sales service:Phone:Contact:

.+49 (0) 911 703 - 22 [email protected]

Technical specifications