GUARDIAN : Bridge Navigation Watch Alarm System (B N W A S)
Installation Guidelines & Commissioning
First Line Fault Finding
Wiring & Schematic Diagrams
GUARDIAN B N W A S
GUARDIAN : Bridge Navigation Watch Alarm System (BNWAS) Installation & Commissioning Guidelines
First Line Fault Finding
Schematic Wiring Diagrams
GUARDIAN B N W A S
Installation & Commissioning Guidelines - Page 2
B N W A S
Ref: C-VIGIL/BNWAS/MANUALS/2.2 C-VIGIL Ltd : marine [email protected]
GUARDIAN
Revisions Records
Revision Record
Document Ref:
Date: Authorised By:
2.1
May 2011
2.2
June 2011
Installation & Commissioning Guidelines - Page 3
B N W A S
Ref: C-VIGIL/BNWAS/MANUALS/2.2 C-VIGIL Ltd : marine [email protected]
GUARDIAN Contents
REVISIONS RECORDS .......................................................................................................................................... 2
1. REFERENCES ............................................................................................................................................. 6
2.1 Location ................................................................................................................................................... 8
2.2 Directional PIRs ........................................................................................................................................ 8
3. HMI TOUCH SCREEN DISPLAY ................................................................................................................. 10
3.1 Location ................................................................................................................................................. 10
3.2 Panel Mount .......................................................................................................................................... 10
3.3 Surface Mount ....................................................................................................................................... 10
4. MAIN PLC CONTROL PANEL .................................................................................................................... 13
4.1 Location ................................................................................................................................................. 13
5. PAGING SYSTEM .................................................................................................................................... 15
5.1 Location ................................................................................................................................................. 15
6. WIRELESS PANIC BUTTON SYSTEM ......................................................................................................... 17
6.1 Location ................................................................................................................................................. 17
7. NORMAL/MANUAL OFF & MANUAL RESET/EMERGENCYCALL PANEL..................................................... 19
7.1 Location ................................................................................................................................................. 19
7.2 Panel Mount .......................................................................................................................................... 19
7.3 Surface Mount ....................................................................................................................................... 19
8. MANUAL RESET / EMERGENCY CALL PANEL ........................................................................................... 22
8.1 Location ................................................................................................................................................. 22
9. WARNING DEVICES ................................................................................................................................ 24
9.1 Bridge Beacon – Visual ........................................................................................................................... 24
9.1.1 Location ............................................................................................................................................ 24
9.2 Bridge Sounder – Audible ....................................................................................................................... 24
9.2.1 Location ............................................................................................................................................ 24
Installation & Commissioning Guidelines - Page 4
B N W A S
Ref: C-VIGIL/BNWAS/MANUALS/2.2 C-VIGIL Ltd : marine [email protected]
GUARDIAN
9.3 Cabin & Public Room – Audio/Visual ...................................................................................................... 25
9.3.1 Location ............................................................................................................................................ 25
9.3.2 Bed-Head Sounder ............................................................................................................................ 25
10. CONNECTING TO OTHER NAVIGATION EQUIPMENT ............................................................................... 28
10.1 Autopilot ............................................................................................................................................... 28
10.2 GPS ................................................................................................................................................... 28
10.3 Reset from Other Bridge Equipment ................................................................................................. 29
10.4 Unacknowledged Navigation Alarm Transfer .................................................................................... 29
10.5 Mains Failure Output to Central Alarm System ................................................................................. 29
11. VDR OUTPUT CHECK .............................................................................................................................. 31
12. CABLING ................................................................................................................................................ 33
13. COMMISSIONING ................................................................................................................................... 35
14. FIRST LINE FAULT FINDING ..................................................................................................................... 40
APPENDIX A ..................................................................................................................................................... 45
Technical Drawings & Schematics .................................................................................................................... 45
APPENDIX B ..................................................................................................................................................... 46
Reserve Power Requirements .......................................................................................................................... 46
Installation & Commissioning Guidelines - Page 5
B N W A S
Ref: C-VIGIL/BNWAS/MANUALS/2.2 C-VIGIL Ltd : marine [email protected]
GUARDIAN
INTENTIONALLYLEFTBLANK
Installation & Commissioning Guidelines - Page 6
B N W A S
Ref: C-VIGIL/BNWAS/MANUALS/2.2 C-VIGIL Ltd : marine [email protected]
GUARDIAN
1. References Reference is made to APPENDIX A at the end of these guidelines, where schematics and drawings are available. These instructions are intended to assist in the installation of the GUARDIAN : BNWAS system; as every vessel is different these are general guidelines only. Please refer to Manufacturer’s Equipment Data Sheets Reference: APPENDIX A – Schematics & Drawings: - Please refer to manufacturer’s literature.
Installation & Commissioning Guidelines - Page 7
B N W A S
Ref: C-VIGIL/BNWAS/MANUALS/2.2 C-VIGIL Ltd : marine [email protected]
GUARDIAN
INTENTIONALLYLEFTBLANK
Installation & Commissioning Guidelines - Page 8
B N W A S
Ref: C-VIGIL/BNWAS/MANUALS/2.2 C-VIGIL Ltd : marine [email protected]
GUARDIAN
2. PIR Installation
2.1 Location Positioning – The PIRs should be sited to give full coverage of the bridge operational areas normally occupied by the Navigating Officers carrying out their normal duties – typically 2.3m high. Care should be taken when selecting positions – where possible avoid installing: - Above heaters Directly over or in line with air conditioning vents (punkas…etc). Direct sunlight If the bridge wing areas are to be monitored (Owner’s preference), external IP65 PIRs should be used for the open air type. For Owners requiring the highest safety standard especially for tankers, gas carriers…etc, hazardous area PIRs should be used in conjunction with a zener barrier. Where the bridge wings are covered, directional PIRs should be used to cover these areas. To ensure full coverage, with no blind spots, 360O PIRs should be used at a central position. These all round detectors should also be used where the chart table area has black-out curtains.
2.2 Directional PIRs
Reference: APPENDIX A – Schematics & Drawings: - Drawing Title: DWG007 Directional PIR Drawing Title: DWG007.1 Directional PIR – Dimensions Drawing Title: DWG007.2 Directional PIR - Wiring Please refer to manufacturer’s literature. The directional PIRs should be fitted, where possible, to the overhead deck-head panels at suitable positions to face inwards to the bridge operational area (internal bridge wing areas should not be overlooked). Remove the detector’s front cover as per manufacturer’s data sheet. Ascertain were cable entry will be and remove the most appropriate round “knock-out” piece in the rear of the detector or drill a suitably sized hole. With the detector in position feed the cable through the “knock-out” hole. Carefully strip the cable and attach bootlace ferrules to each wire. Attach the wires to the appropriate terminals according to the wiring schematic. Leave the front cover off till the “walk-test” has been carried out – during commissioning & setup. Carry-out the commissioning procedures outlined at the end of these guidelines. After commissioning carefully re-attach the front cover.
Installation & Commissioning Guidelines - Page 9
B N W A S
Ref: C-VIGIL/BNWAS/MANUALS/2.2 C-VIGIL Ltd : marine [email protected]
GUARDIAN
INTENTIONALLYLEFTBLANK
Installation & Commissioning Guidelines - Page 10
B N W A S
Ref: C-VIGIL/BNWAS/MANUALS/2.2 C-VIGIL Ltd : marine [email protected]
GUARDIAN
3. HMI Touch Screen Display Reference: APPENDIX A – Schematics & Drawings: - Drawing Title: DWG005 HMI User Display Drawing Title: DWG005.1 HMI User Display – Dimensions Drawing Title: DWG005.2 HMI User Display - Wiring Please refer to manufacturer’s literature.
3.1 Location The Human Machine Interface (HMI) touch screen User Display should be fitted, where possible, in a position where it can be clearly seen form the normal bridge operational positions. The display can be fitted as: -
Panel mount (flush mounted into existing Navigation equipment consoles) or Surface mount (desktop enclosure)
The display is connected to the main control console by an RS422 Cat5 ethernet data cable. The display requires a 24V DC supply, usually from the main control panel, or from a local supply if preferred.
3.2 Panel Mount Provided there is sufficient space, the HMI User Display ideally should be installed in the main navigation console – the display measures 201mm x 152mm x 67mm requiring a cut-out of 179mm x 129mm. The HMI User Display is secured from the rear using the screwed adjustable fixings supplied. Insert the 25 way connector into the socket at the bottom of the display and tighten the securing thumbs screws. Connect the 24V DC supply to the terminals using bootlace ferrules and ensure the cables are well supported.
3.3 Surface Mount In installations where there is insufficient room on the main nav console a position should be selected where the HMI User Display can be surface mounted and still be clearly visible from the normal operational positions. The unit is supplied in an enclosure with an adjustable mounting bracket.
Installation & Commissioning Guidelines - Page 11
B N W A S
Ref: C-VIGIL/BNWAS/MANUALS/2.2 C-VIGIL Ltd : marine [email protected]
GUARDIAN The mounting bracket should be attached securely to the surface using either self tapping screws or securing bolts. Insert the 25 way connector into the socket at the bottom of the display and tighten the securing thumbs screws. Connect the 24V DC supply to the terminals using bootlace ferrules and ensure the cables are well supported. Carry-out the commissioning procedures outlined at the end of these guidelines.
Installation & Commissioning Guidelines - Page 12
B N W A S
Ref: C-VIGIL/BNWAS/MANUALS/2.2 C-VIGIL Ltd : marine [email protected]
GUARDIAN
INTENTIONALLYLEFTBLANK
Installation & Commissioning Guidelines - Page 13
B N W A S
Ref: C-VIGIL/BNWAS/MANUALS/2.2 C-VIGIL Ltd : marine [email protected]
GUARDIAN
4. Main PLC Control Panel Reference: APPENDIX A – Schematics & Drawings: - Drawing Title: DWG001.2 System Interconnections Drawing Title: DWG001.3 System Wiring Drawing Title: DWG001.4 System PSU Wiring Drawing Title: DWG001.5 NMEA I/O Interface Drawing Title: DWG001.6 Autopilot I/P Drawing Title: DWG001.7 Additional Bridge Equipment Drawing Title: DWG001.8 Transfer Alarm I/P Drawing Title: DWG001.9 Central Alarm O/P Drawing Title: DWG001.10 VDR NMEA Output Drawing Title: DWG002 Main Terminal Strip – TB1 Drawing Title: DWG002.1 Main Terminal Strip – TB2 Drawing Title: DWG002.2 Main Terminal Strip – TB3 Drawing Title: DWG004 Main PLC Unit /IO Please refer to manufacturer’s literature.
4.1 Location
The main control panel should be situated in a suitable location that allows easy access for installation, commissioning and servicing ideally on the bridge, however if there is no space available then it can be situated in an electrical locker, cable space, storage locker…etc as once switched on all the user operations are performed through the HMI User Display unit.
The panel can be installed inside existing control panels provided there is sufficient space – the Main Control Panel being 300mm x 300mm x 120mm, please allow for the hinged door. The panel is to be bulkhead mounted using the securing kit provided and be at least 100mm up from the deck (to allow for bottom entry cables). Mark the position and secure the control panel using suitable self tapping screws.
The panel is fitted with a ventilation fan so please allow at least 100mm clearance on both sides to allow for adequate air flow (the unit develops very little heat, so overheating should not be a problem). External equipment connections are brought into and out of the Main Control Panel via the cable glands located on the underside gland plate. Equipment connections are made to the various terminal rails, as per the drawings, using bootlace ferrules. Carry-out the commissioning procedures outlined at the end of these guidelines.
Installation & Commissioning Guidelines - Page 14
B N W A S
Ref: C-VIGIL/BNWAS/MANUALS/2.2 C-VIGIL Ltd : marine [email protected]
GUARDIAN
INTENTIONALLYLEFTBLANK
Installation & Commissioning Guidelines - Page 15
B N W A S
Ref: C-VIGIL/BNWAS/MANUALS/2.2 C-VIGIL Ltd : marine [email protected]
GUARDIAN
5. Paging System Reference: APPENDIX A – Schematics & Drawings: - Drawing Title: DWG010 Paging Transmitter Drawing Title: DWG010.1 Paging Transmitter – Dimensions Drawing Title: DWG010.2 Paging Transmitter - Wiring Please refer to manufacturer’s literature.
5.1 Location Where possible the paging transmitter should be bulkhead mounted and installed in a position adjacent to a bridge window – this should increase the range to the open deck area. Carefully remove the front cover and unplug the wandering leads. Fix the transmitter to the bulkhead, through the mounting holes, using small self tapping screws. Connect the power supply and trigger cables to the appropriate terminals, as per the drawings, using bootlace ferrules. The cables should be brought in through the grommets in the underside of the unit. Carefully replace the wandering lead connections and the front cover. Carry-out the commissioning procedures outlined at the end of these guidelines.
Installation & Commissioning Guidelines - Page 16
B N W A S
Ref: C-VIGIL/BNWAS/MANUALS/2.2 C-VIGIL Ltd : marine [email protected]
GUARDIAN
INTENTIONALLYLEFTBLANK
Installation & Commissioning Guidelines - Page 17
B N W A S
Ref: C-VIGIL/BNWAS/MANUALS/2.2 C-VIGIL Ltd : marine [email protected]
GUARDIAN
6. Wireless Panic Button System Reference: APPENDIX A – Schematics & Drawings: - Drawing Title: DWG016 Wireless Panic Button Drawing Title: DWG016.1 Wireless Panic Button – Dimensions Drawing Title: DWG016.2 Wireless Panic Button - Wiring Please refer to manufacturer’s literature.
6.1 Location Where possible the wireless receiver should be bulkhead mounted and installed in a position central to the bridge – this should increase the receivers range. Carefully remove the front cover. Fix the transmitter to the bulkhead, through the mounting holes, using small self tapping screws. Connect the power supply and switched output cables to the appropriate terminals, as per the drawings, using bootlace ferrules. The cables should be brought in through the gland in the underside of the unit. Carefully replace the front cover. Carry-out the commissioning procedures outlined at the end of these guidelines.
Installation & Commissioning Guidelines - Page 18
B N W A S
Ref: C-VIGIL/BNWAS/MANUALS/2.2 C-VIGIL Ltd : marine [email protected]
GUARDIAN
INTENTIONALLYLEFTBLANK
Installation & Commissioning Guidelines - Page 19
B N W A S
Ref: C-VIGIL/BNWAS/MANUALS/2.2 C-VIGIL Ltd : marine [email protected]
GUARDIAN
7. Normal/Manual Off & Manual Reset/EmergencyCall Panel
Reference: APPENDIX A – Schematics & Drawings: - Drawing Title: DWG001.12 Manual Reset Button Wiring Drawing Title: DWG008 Norm/Off & Reset/Emgy Call Drawing Title: DWG008.1 Norm/Off & Reset/Emgy Call – Dimensions Drawing Title: DWG008.2 Norm/Off & Reset/Emgy Call - Wiring Please refer to manufacturer’s literature.
7.1 Location The Normal/Off & Manual Reset/Emergency Call Panel should be fitted, where possible, in a position that is easily accessible, ideally located on the main nav console. The display can be fitted as: -
Panel mount (flush mounted into existing Navigation equipment consoles or Surface mount (desktop enclosure)
The panel is connected to the main control console by Cat 5 ethernet cable.
7.2 Panel Mount Provided there is sufficient space the Normal/Off & Manual Reset/Emergency Call Panel ideally should be installed in the main navigation console – the panel measures 150mm x 75mm x 67mm requiring a cut-out of 120mm x 60mm. The Normal/Off & Manual Reset/Emergency Call Panel is secured through the front panel fixings. Once positioned connect the ethernet cable to the terminals, as per the drawings, using bootlace ferrules and ensure the cables are well supported. Carry-out the commissioning procedures outlined at the end of these guidelines.
7.3 Surface Mount In instances where there is insufficient room on the main nav console a position should be selected where the Normal/Off & Manual Reset/Emergency Call Panel can be surface mounted and still be easily accessible.
Installation & Commissioning Guidelines - Page 20
B N W A S
Ref: C-VIGIL/BNWAS/MANUALS/2.2 C-VIGIL Ltd : marine [email protected]
GUARDIAN The panel should be secured through the base. Once positioned connect the ethernet cable to the terminals, as per the drawings, using bootlace ferrules and ensure the cables are well supported. Carry-out the commissioning procedures outlined at the end of these guidelines.
Installation & Commissioning Guidelines - Page 21
B N W A S
Ref: C-VIGIL/BNWAS/MANUALS/2.2 C-VIGIL Ltd : marine [email protected]
GUARDIAN
INTENTIONALLYLEFTBLANK
Installation & Commissioning Guidelines - Page 22
B N W A S
Ref: C-VIGIL/BNWAS/MANUALS/2.2 C-VIGIL Ltd : marine [email protected]
GUARDIAN
8. Manual Reset / Emergency Call Panel Reference: APPENDIX A – Schematics & Drawings: - Drawing Title: DWG001.12 Manual Reset Button Wiring Drawing Title: DWG009 Reset/Emgy Call Button Drawing Title: DWG009.1 Reset/Emgy Call Button - Dimensions Drawing Title: DWG009.2 Reset/Emgy Call Button - Wiring Please refer to manufacturer’s literature.
8.1 Location The reset buttons are to be conveniently installed at suitable positions around the bridge. Depending on the size of vessel will dictate the number of Reset Panels required. Typical locations for installation would be: - Conning position Bridge wing areas – port and stbd Chart table area These buttons allow the OOW to manually reset the system or initiate an Emergency Call at the above locations. The panels should be secured through the base using self tapping screws. Cable entry is via suitably sized cable glands which can be both, top or bottom entry. Connections are made, as per the drawings, to the terminals using bootlace ferrules. Carry-out the commissioning procedures outlined at the end of these guidelines.
Installation & Commissioning Guidelines - Page 23
B N W A S
Ref: C-VIGIL/BNWAS/MANUALS/2.2 C-VIGIL Ltd : marine [email protected]
GUARDIAN
INTENTIONALLYLEFTBLANK
Installation & Commissioning Guidelines - Page 24
B N W A S
Ref: C-VIGIL/BNWAS/MANUALS/2.2 C-VIGIL Ltd : marine [email protected]
GUARDIAN
9. Warning Devices
9.1 Bridge Beacon – Visual Reference: APPENDIX A – Schematics & Drawings: - Drawing Title: DWG001.11 System A/V Wiring Drawing Title: DWG013 Bridge Beacon Drawing Title: DWG013.1 Bridge Beacon – Dimensions Drawing Title: DWG013.2 Bridge Beacon - Wiring Please refer to manufacturer’s literature.
9.1.1 Location The bridge visual beacon should be secured to a bulkhead or deck-head panel in such a position where it can be easily seen from the normal operational positions. The front cover should be removed and the base secured to the bulkhead using self tapping screws. The cable should be brought in via the cable gland and connected to the appropriate terminals, as per the drawing, using bootlace ferrules. Re-attach the front cover. Carry-out the commissioning procedures outlined at the end of these guidelines.
9.2 Bridge Sounder – Audible Reference: APPENDIX A – Schematics & Drawings: - Drawing Title: DWG001.11 System A/V Wiring Drawing Title: DWG012 Bridge Sounder Drawing Title: DWG012.1 Bridge Sounder – Dimensions Drawing Title: DWG012.2 Bridge Sounder - Wiring Please refer to manufacturer’s literature.
9.2.1 Location The bridge audible sounder should be secured to a bulkhead or deck-head panel in such a position where it can be easily heard from the normal conning position. The front cover should be removed and the base secured to the bulkhead using self tapping screws.
Installation & Commissioning Guidelines - Page 25
B N W A S
Ref: C-VIGIL/BNWAS/MANUALS/2.2 C-VIGIL Ltd : marine [email protected]
GUARDIAN The cable should be brought in via the cable gland and connected to the appropriate terminals, as per the drawing, using bootlace ferrules. Re-attach the front cover. Carry-out the commissioning procedures outlined at the end of these guidelines.
9.3 Cabin & Public Room – Audio/Visual Reference: APPENDIX A – Schematics & Drawings: - Drawing Title: DWG001.11 System A/V Wiring Drawing Title: DWG014 Cabin & Public Room AV Drawing Title: DWG014.1 Cabin & Public Room AV – Dimensions Drawing Title: DWG014.2 Cabin & Public Room AV - Wiring Please refer to manufacturer’s literature.
9.3.1 Location The accommodation audio/visual devices should be installed in each of the navigating officers cabins including the Master’s cabin (if required). These audio/visual devices should also be installed in the public rooms normally used by the navigating officers i.e. Officers mess, Officers lounge, video lounge, gymnasium…etc. A suitable position should be selected where the alarm can be easily be seen and heard. The front cover should be removed and the base secured to the bulkhead using self tapping screws. The cable should be brought in via the cable gland and connected to the appropriate terminals, as per the drawing, using bootlace ferrules. Re-attach the front cover. Carry-out the commissioning procedures outlined at the end of these guidelines.
9.3.2 Bed-Head Sounder Reference: APPENDIX A – Schematics & Drawings: - Drawing Title: DWG001.11 System A/V Wiring Drawing Title: DWG015 Bed-head Sounder Drawing Title: DWG015.1 Bed-head Sounder – Dimensions Drawing Title: DWG015.2 Bed-head Sounder - Wiring Please refer to manufacturer’s literature.
Installation & Commissioning Guidelines - Page 26
B N W A S
Ref: C-VIGIL/BNWAS/MANUALS/2.2 C-VIGIL Ltd : marine [email protected]
GUARDIAN In the Master’s & Senior Officer’s cabins that have a separate bedroom the bed-head sounder should be installed adjacent to the sleeping position. The front cover should be removed and the base secured to the bulkhead using self tapping screws. The cable should be brought in via the cable gland and connected to the appropriate terminals, as per the drawing, using bootlace ferrules. Re-attach the front cover. Carry-out the commissioning procedures outlined at the end of these guidelines.
Installation & Commissioning Guidelines - Page 27
B N W A S
Ref: C-VIGIL/BNWAS/MANUALS/2.2 C-VIGIL Ltd : marine [email protected]
GUARDIAN
INTENTIONALLYLEFTBLANK
Installation & Commissioning Guidelines - Page 28
B N W A S
Ref: C-VIGIL/BNWAS/MANUALS/2.2 C-VIGIL Ltd : marine [email protected]
GUARDIAN
10. Connecting to Other Navigation Equipment
Reference: APPENDIX A – Schematics & Drawings: - Drawing Title: DWG001.5 NMEA Interface Drawing Title: DWG001.6 Autopilot/GPS Interface Drawing Title: DWG001.7 Other bridge equipment - reset Drawing Title: DWG001.8 Transfer Nav Alarm Drawing Title: DWG001.9 Central Alarm System Please refer to manufacturer’s literature.
10.1 Autopilot Ascertain, through testing or document scrutiny, the output signal type when the autopilot is set to heading control i.e. 4-30V DC or NMEA $__HTDxxxx* Set the NMEA Interface PCB switch SW1 as follows: - 4-30V DC : set SW1-2 On $__HTDxxxx* : set SW1-2 Off Carry-out the commissioning procedures outlined at the end of these guidelines.
10.2 GPS
If required the BNWAS automatic Active selection can be controlled by the ship’s speed, using the $GPVTGxxxx sentence from the GPS. Once the ship exceeds 3kts the BNWAS is set to Active irrespective of heading control. To enable this function: - Select a suitable point to connect to the GPS data output i.e. NMEA buffer/distributor…etc. Set the NMEA Interface PCB switch SW-1 as follows: - Use $GPVTGxxxx3.0*: set SW1-1 Off Ignore $GPVTGxxxx3.0* : set SW1-1 On Carry-out the commissioning procedures outlined at the end of these guidelines.
4
2 3
1 2 1
NMEA Interface PCB Switch SW1
Switch SW1 Positions
Off On
NMEA Interface PCB Switch SW1
Installation & Commissioning Guidelines - Page 29
B N W A S
Ref: C-VIGIL/BNWAS/MANUALS/2.2 C-VIGIL Ltd : marine [email protected]
GUARDIAN
10.3 Reset from Other Bridge Equipment Ascertain, from documentation scrutiny, whether the bridge navigational equipment is capable of generating a reset signal when the nav equipment is adjusted. Connect to the output relay that generates a closing signal when the equipment is adjusted. Carry-out the commissioning procedures outlined at the end of these guidelines.
10.4 Unacknowledged Navigation Alarm Transfer Ascertain, through testing or documentation scrutiny, which of the navigational equipment is capable of generating a fault condition alarm i.e. heading control – off track alarm, GPS alarm…etc. The NMEA interface pcb accepts $__ALRxxxx* sentences from the autopilot and GPS through the connection described above. Other equipment should be connected as per the wiring schematics and drawings. The system will accept alarm signals in either 4-30V DC or $__ALRxxxx* format. Set the NMEA Interface PCB switch SW1 as follows: - Alarm I/P 1 4-30V DC : set SW1-3 On $__ALRxxxx* : set SW1-3 Off Alarm I/P 2 4-30V DC : set SW1-4 On $__ALRxxxx* : set SW1-4 Off For connections to additional nav equipment an expansion board is available. Carry-out the commissioning procedures outlined at the end of these guidelines.
10.5 Mains Failure Output to Central Alarm System The BNWAS can connect to the ship’s central alarm system or bridge alarm system. Ascertain which format of signal is required i.e. N/O or N/C. Carry-out the commissioning procedures outlined at the end of these guidelines.
Installation & Commissioning Guidelines - Page 30
B N W A S
Ref: C-VIGIL/BNWAS/MANUALS/2.2 C-VIGIL Ltd : marine [email protected]
GUARDIAN
INTENTIONALLYLEFTBLANK
Installation & Commissioning Guidelines - Page 31
B N W A S
Ref: C-VIGIL/BNWAS/MANUALS/2.2 C-VIGIL Ltd : marine [email protected]
GUARDIAN
11. VDR Output Check
With the system fully connected and tested, check that the $BNALRxxxx* NMEA output sentence to VDR: - Put the system to Active – 3 mins From the Main Screen Press Menus button From the Options Menu press View Settings button Press Next on each screen till you arrive at the VDR Sentence screen. Allow the system to progress to the 3rd Stage alarm and check the $BNALR output sentence changes accordingly: - $ B N A L R , , 0 0 0 , A , V , C 1 = A U T ; C 2 = 3 ; C 3 = 0 * h h < C R > < L F > $ = Start of sentence
BN = Equipment identifier (BN = BNWAS)
ALR = Sentence type (ALR = Alarm)
000 = Designation of source alarm (000 = Automatic)
A = A = Dormant period exceeded
V = Dormant period not exceeded
V = A = Alarm acknowledged
V = Alarm unacknowledged
C1 = AUT or MAN or OFF
C2 = Dormant period in mins (3-12)
C3 = Alarm stage 0, 1, 2 or 3 (0 = normal, 1 = 1st stage…etc)
* = End of sentence
hh = Checksum
<CR> = Carriage Return
<LF> = Line Feed
Installation & Commissioning Guidelines - Page 32
B N W A S
Ref: C-VIGIL/BNWAS/MANUALS/2.2 C-VIGIL Ltd : marine [email protected]
GUARDIAN
INTENTIONALLYLEFTBLANK
Installation & Commissioning Guidelines - Page 33
B N W A S
Ref: C-VIGIL/BNWAS/MANUALS/2.2 C-VIGIL Ltd : marine [email protected]
GUARDIAN
12. Cabling
All installed cabling should where possible, be laid in existing cable routes. All cabling, should where possible, be hidden behind bulkhead and deck-head panels. Any surface run cabling should be in suitable cable trunking or neatly clipped up. All cabling should be securely fastened and supported. Where cables pass through bulkheads and deck-heads existing penetrations should be utilised or other suitably approved penetrations used. No sharp edges permitted – all cut holes to be de-burred and/or sleeved with grommets.
Installation & Commissioning Guidelines - Page 34
B N W A S
Ref: C-VIGIL/BNWAS/MANUALS/2.2 C-VIGIL Ltd : marine [email protected]
GUARDIAN
INTENTIONALLYLEFTBLANK
Installation & Commissioning Guidelines - Page 35
B N W A S
Ref: C-VIGIL/BNWAS/MANUALS/2.2 C-VIGIL Ltd : marine [email protected]
GUARDIAN
13. Commissioning
*Caution* DO NOT CONNECT OR SWITCH ON POWER TILL ALL EQUIPMENT HAS BEEN CONNECTED AND CHECKED Initial Checks
Ensure ALL the equipment has been installed and connected satisfactory – it is advisable to double check all connections are correct and all terminals are tight.
Power-Up
> Incoming Mains : Close the ship’s mains MCCB. >Incoming 24V DC : Close the ship’s supply MCCB > Main Control Panel : Close the mains fuses F1 & F2. > Main Control Panel : Close the 24V DC fuses F3 & F4. > Make sure the ventilation fan is running. > Make sure the control panel front cover Supply LED is lit. > Check the PLC unit shows signs of being powered-up – small red LED activity. > Ensure the HMI User Display unit boots up to the main screen.
Do NOT proceed to the next step if the above conditions are not evident. Note: As the PIR covers are off at this stage the tamper alarm and indication will be active. Please acknowledge this alarm condition before proceeding. Program Initial Settings
> Through the Menu options ensure ALL the cabin sounders are switched on – see User Manual for this procedure.
PIR Detection Testing
Directional PIRs > Select PIR Test – refer to User Manual > On each PIR… > Set alarm LED jumper link to Enabled – for walk testing. > Approach each PIR and observe that the alarm LED is lit as the sensor detects your movements. > Check on the HMI Display PIR test screen that the PIR has operated. > When you are satisfied with the PIRs operation… > Set alarm LED link to Disabled. > Replace the front cover. > Check on the HMI Display PIR test screen that the PIR still operates.
PIR Anti-Tamper Testing Ensure the tamper alarm has been cancelled / reset on the HMI User Display screen. NOTE : For unused PIR connections a shorting link should be inserted in the main terminal strip.
On each PIR…
> Remove the PIR front cover. > Check on the User Display that the tamper alarm has operated correctly. > Reset the tamper alarm between each PIR test. > When you are satisfied with the PIRs operation… > Replace the front cover. > Check on the HMI Display PIR test screen that the PIR still operates.
Installation & Commissioning Guidelines - Page 36
B N W A S
Ref: C-VIGIL/BNWAS/MANUALS/2.2 C-VIGIL Ltd : marine [email protected]
GUARDIAN On completion of the PIR test set the system to ‘Active’ mode and walk round the bridge protected area, ensure that the interval timer resets during this walk round stage. Bridge Visual Alarm Testing
> Set the ‘Active’ dormant period timer to 3 min – please refer to User Manual. > Remain motionless and allow the dormant time period to elapse. > HMI User Display screen should now display Alarm Sequence. > Ensure the bridge visual beacon and illuminated push buttons now activate.
Bridge Sounder – Audible Testing
> Repeat the above test, this time; permit the 1st Stage alarm to operate. > Ensure the bridge audible sounder now activates.
Cabin & Public Room Audio/Visual Alarm Testing
> Repeat the above test, this time; permit the 2nd Stage alarm to operate. > Ensure the cabin audible/visual alarm(s) now activates.
Ensure all installed warning devices operate correctly. Paging System Testing Ensure all the pocket pagers are gathered on the bridge and switched on
> This test should be carried out at the same time as Cabin Alarm tests. > Allow the 2nd Stage to operate. > HMI User Display screen should now display Alarm Sequence. > Ensure ALL the pocket pagers are activated. > Test the pagers at various points round the vessel, note any dead spots.
Panic Button System Testing Ensure all the key fob transmitters are gathered on the bridge.
> Press and hold the key fob button for more than 3 seconds > Ensure the 2nd and 3rd stage alarms are activated > HMI User Display screen should now display the Emergency Call screen. > Cancel the alarm.. > Test the key fobs at various points round the bridge, note any dead spots.
Alarm Reset Testing
> Set the Mode to ‘Active’. > Remain motionless till the bridge beacon & sounder activates, now test that any detected movement turns these warning devices off. >From the HMI User Display press the Manual Reset button and ensure the same result. > Operate the Manual Reset buttons from the various installed positions and ensure the same results.
Emergency Call Testing
> Ensure this facility operates in all modes.
Installation & Commissioning Guidelines - Page 37
B N W A S
Ref: C-VIGIL/BNWAS/MANUALS/2.2 C-VIGIL Ltd : marine [email protected]
GUARDIAN > From the HMI User Display unit press and hold the Emergency Call button for longer than 3 seconds. > Ensure that all the warning devices operate. > Repeat this test from all of the Manual Reset / EmergencyCall buttons
Normal / Manual Off Testing
> From the Normal / Manual Off panels use the key switch and select the Manual Off position. > Ensure the User Display shows Manual Off. > Select the Normal position > Ensure the User Display returns to Manual / Inactive
Reserve Power Testing
> Open the main control enclosure door. > Open the incoming mains fuses F1 & F2. > Accept the Mains Fail warning > After completion of satisfactory test close fuses F1 & F2.
Autopilot Automatic Activation
> Set system to Automatic / Inactive – see User Manual > Set autopilot to heading control > Ensure BNWAS changes from Inactive to Active > Set autopilot back to hand / manual steering > Ensure BNWAS changes back to Inactive
GPS Automatic Activation
> Set system to Automatic / Inactive – see User Manual > Observe BNWAS as vessel proceeds to sea > Ensure BNWAS changes to Active when vessel’s speed exceeds 3kts > Ensure BNWAS changes to Inactive when vessel’s speed drops below 3kts
Reset Signal from Other Navigation Equipment
> Set system to Manual / Active > Whilst observing dormant period progress bar operate a connected piece of navigation equipment > Ensure dormant time period is reset
Unacknowledged Navigation Alarm Transfer
> Force a connected piece of navigation equipment into alarm > Wait 30 seconds for the BNWAS to respond > Ensure the BNWAS responds by activating the 2nd / 3rd stage alarms
Mains Failure to Ship’s Central / Bridge Alarm
> Open mains fuses F1 or F2 > Check local failure indication on User display > Check ship’s alarm system indicated BNWAS fault.
Output to VDR
> Put system into Active mode > On HMI open VDR output screen – see User Manual
Installation & Commissioning Guidelines - Page 38
B N W A S
Ref: C-VIGIL/BNWAS/MANUALS/2.2 C-VIGIL Ltd : marine [email protected]
GUARDIAN > Allow system to enter alarm stages > Check $BNALRxxxx changes with staged alarms > Check at VDR that $BNALRxxxx NMEA sentence is being received correctly
Installation & Commissioning Guidelines - Page 39
B N W A S
Ref: C-VIGIL/BNWAS/MANUALS/2.2 C-VIGIL Ltd : marine [email protected]
GUARDIAN
INTENTIONALLYLEFTBLANK
Installation & Commissioning Guidelines - Page 40
B N W A S
Ref: C-VIGIL/BNWAS/MANUALS/2.2 C-VIGIL Ltd : marine [email protected]
GUARDIAN
14. First Line Fault Finding . Main Control Panel
No Power Indication > Using multi-meter check for incoming ship’s mains & 24V DC on TB1 > Check PSU & MCU fuses F1 to F8 > Check wiring connections > If all OK – contact Bridge-Watch (see contact details page)
Incorrect Operation > Abnormal operation suspected - contact Bridge-Watch (see contact details page)
HMI User Display Unit
No Power Indication > Check blue front panel LED – should be on > Using multi-meter check for incoming 24V DC on rear of unit > If not present – check for 24V DC on control panel TB3 refer to Schematic Dwgs > If not present – check fuses on TB2 – F6 > If not present – check main 24V fuses F3 & F4 > Check wiring connections > If all OK – contact Bridge-Watch (see contact details page)
No Information Displayed
>Is Comms Error display on HMI? > Check RS422 comms cable is connected securely – on bottom of unit > Check RS422 comms cable is connected securely at PLC unit – on front > If all OK – contact Bridge-Watch (see contact details page)
Paging System
No Power Indication > Check green front panel supply LED – should be on > Using multi-meter check for 12V DC on power terminals > If not present - check for 12V DC on TB3 refer to Schematic Dwgs > If not present - check fuses on TB2 – F8 > If not present – check main 24V fuses F3 & F4 > Check wiring connections > If all OK – contact Bridge-Watch (see contact details page)
No Paging Transmission
> Switch ALL pocket pagers on > From HMI unit use ‘Test Pager’ to send test paging transmission > Check wiring connections > If no page received on ANY pager, then - contact Bridge-Watch (see contact details page)
No Paging Transmission Received
> Switch ALL pocket pagers on > From HMI unit use ‘Test Pager’ to send test paging transmission > Note which pager does not receive paging transmission > Replace batteries > If still no difference – contact Bridge-Watch (see contact details page)
Installation & Commissioning Guidelines - Page 41
B N W A S
Ref: C-VIGIL/BNWAS/MANUALS/2.2 C-VIGIL Ltd : marine [email protected]
GUARDIAN Panic Button System
No Activation > Remove front cover and press key fob – check red led activates > Using multi-meter check for 12V DC on power terminals > If not present - check for 12V DC on TB3 refer to Schematic Dwgs > If not present - check fuses on TB2 – F8 > If not present – check main 24V fuses F3 & F4 > Check wiring connections > Check key fob batteries > If all OK – contact Bridge-Watch (see contact details page)
Manual Push Buttons
No LED Illumination > Allow system to enter alarm mode On rear of push button panel… > Using multi-meter - check for 12V DC on terminal 1 & 2 > If not present – check for 12V DC on TB3 refer to Schematic Dwgs > If not present – check fuse on TB2 – F8 > If not present – check main 24V fuses F3 & F4 > Check wiring connections > If all OK – contact Bridge-Watch (see contact details page)
No Reset Operation
> Allow system to enter alarm mode > Press reset button If alarm not reset, then… > On rear of push button panel… > Disconnect wiring to terminals 3 & 4 > Using multi-meter – check for continuity when pressing button > Check wiring connections > If all OK – contact Bridge-Watch (see contact details page)
Warning Devices Bridge Beacon – No Operation
> From HMI select ‘Bridge Strobe’ test > Using multi-meter – check for 24V DC on terminal connections on suspect unit > If not present – check for 24V DC on TB3 refer to Schematic Dwgs > If not present – check fuse on TB2 – F7 > If not present – check main 24V fuses F3 & F4 > Check wiring connections > If all OK – contact Bridge-Watch (see contact details page)
Bridge Sounder – No Operation
> From HMI select ‘Bridge Sounder’ test > Using multi-meter – check for 24V DC on terminal connections on suspect unit > If not present – check for 24V DC on TB3 refer to Schematic Dwgs > If not present – check fuse on TB2 – F7 > If not present – check main 24V fuses F3 & F4 > Check wiring connections > If all OK – contact Bridge-Watch (see contact details page)
Cabin A/V Devices – No Operation
> From HMI select ‘Cabin Sounder’ test > Using multi-meter – check for 24V DC on terminal connections of suspect units > If not present – check for 24V DC on TB3 refer to Schematic Dwgs > If not present – check fuse on TB2 – F7 > If not present – check main 24V fuses F3 & F4 > Check wiring connections
Installation & Commissioning Guidelines - Page 42
B N W A S
Ref: C-VIGIL/BNWAS/MANUALS/2.2 C-VIGIL Ltd : marine [email protected]
GUARDIAN > If all OK – contact Bridge-Watch (see contact details page)
Public Room A/V Devices – No Operation
> From HMI select ‘Public Room Sounder’ test > Using multi-meter – check for 24V DC on terminal connections of suspect units > If not present – check for 24V DC on TB3 refer to Schematic Dwgs > If not present – check fuse on TB2 – F7 > If not present – check main 24V fuses F3 & F4 > Check wiring connections > If all OK – contact Bridge-Watch (see contact details page)
PIR Motion Detectors
Directional PIRs – No Operation > On suspect PIR remove front cover > Turn LED to on position > Test if PIR detects your movements > If no indication – check for 12V DC on terminal connections > If not present - check for 12V DC on TB3 – relevant terminals for each PIR > If not present – check fuse of TB2 – F8 > If not present – check main 24V fuses F3 & F4 > Check wiring connections > If all OK – contact Bridge-Watch (see contact details page)
Navigation Equipment I/O
Autopilot > No Automatic change over to Active when heading control mode selected > Check connections at autopilot and BNWAS MCU > Select heading control > Check if yellow LED on NMEA interface PCB activates > Check to see if upper green LED is flashing > Check to see if lower green LED is flashing > Check flashing red LED on PLC RS232 module > Check switch SW1 settings > Check 12V supply on TB3 – see schematic drawing > Report findings to Bridge-Watch (see contact details page)
GPS > No Automatic change over to Active when ship’s speed exceeds 3kts > Check connections at GPS and BNWAS MCU > Check if yellow LED on NMEA interface PCB activates > Check to see if upper green LED is flashing > Check to see if lower green LED is flashing > Check flashing red LED on PLC RS232 module > Check switch SW1 settings > Check 12V supply on TB3 – see schematic drawing > Report findings to Bridge-Watch (see contact details page)
Reset from Other Bridge Navigational Equipment > No resetting when navigation equipment adjusted > Check all wiring and connections > Report findings to Bridge-Watch (see contact details page)
Unacknowledged Nav Alarm Transfer > No unacknowledged alarm transfer to BNWAS system > Check connections at nav equipment and BNWAS MCU > Create alarm condition
Installation & Commissioning Guidelines - Page 43
B N W A S
Ref: C-VIGIL/BNWAS/MANUALS/2.2 C-VIGIL Ltd : marine [email protected]
GUARDIAN > Check if upper left red LED on NMEA interface PCB activates > Check to see if upper green LED is flashing > Check to see if lower green LED is flashing > Check flashing red LED on PLC RS232 module > Check switch SW1 settings > Check 12V supply on TB3 – see schematic drawing > Report findings to Bridge-Watch (see contact details page)
Mains Failure to Ship’s Alarm System > No alarm output to ship’s systems > Open fuses F1 or F2 in MCU > Check alarm indication on User Display > Check wiring and connections > Report findings to Bridge-Watch (see contact details page)
Installation & Commissioning Guidelines - Page 44
B N W A S
Ref: C-VIGIL/BNWAS/MANUALS/2.2 C-VIGIL Ltd : marine [email protected]
GUARDIAN C-VIGIL Ltd : marine (Bridge-Watch) Digital House, Peak Business Park,
Foxwood Rd, Chesterfield, Derbyshire, S41 9RF, UK.
+44 (0)8432 898 464 (Switchboard) +44 (0)1246 269 469 (Direct Tel) +44 (0)1246 351 288 (Direct Fax)
www.bridge-watch.co.uk
Installation & Commissioning Guidelines - Page 45
B N W A S
Ref: C-VIGIL/BNWAS/MANUALS/2.2 C-VIGIL Ltd : marine [email protected]
GUARDIAN APPENDIXA
TechnicalDrawings&Schematics
DWG000 Drawing Register DWG012 Bridge Sounder
General Typical Bridge PIR Deployment DWG012.1 Bridge Sounder – Dimensions
General Typical PIR Detector Patterns DWG012.2 Bridge Sounder – Wiring
DWG001.1 Overview Schematic – Option 1 DWG013 Bridge Beacon
DWG001.2 System Interconnections DWG013.1 Bridge Beacon – Dimension
DWG001.3 System Wiring DWG013.2 Bridge Beacon – Wiring
DWG001.4 System PSU Wiring DWG014 Cabin & Public Room AV Units
DWG001.5 NMEA I/O Interface DWG014.1 Cabin & Public Room AV Units – Dimensions
DWG001.6 Autopilot/GPS I/P DWG014.2 Cabin & Public Room AV Units – Wiring
DWG001.7 Additional Bridge Equipment DWG015 Cabin Bedroom Sounder
DWG001.8 Central Alarm I/P DWG015.1 Cabin & Bedroom Sounder – Dimensions
DWG001.9 Mains Fail to Central Alarm O/P DWG015.2 Cabin & Bedroom Sounder – Wiring
DWG001.10 VDR NMEA Output DWG016 Wireless Panic Button
DWG001.11 Staged Alarms Audible / Visual Wiring DWG016.1 Wireless Panic Button – Dimensions
DWG001.12 Manual Reset/Emgy Call Wiring DWG016.2 Wireless Panic Button – Wiring
DWG002 Main Terminal Strip – TB1 Parts Parts List
DWG002.1 Main Terminal Strip – TB2
DWG002.2 Main Terminal Strip – TB3
DWG003 Main Control Panel
DWG003.1 Main Control Panel – Dimensions
DWG004 Main PLC Unit / IO Details
DWG005 HMI User Display Unit
DWG005.1 HMI User Display Unit – Dimensions
DWG005.2 HMI User Display – Wiring
DWG006 HMI Enclosure
DWG006.1 HMI Surface Mount
DWG007 Directional PIRs
DWG007.1 Directional PIRs – Dimensions
DWG007.2 Directional PIR – Wiring
DWG008 Norm/Off & Reset/Call Button
DWG008.1 Norm/Off & Reset/Call Button – Dims
DWG008.2 Norm/Off & Reset/Call Button – Wiring
DWG009 Reset/Call Button
DWG009.1 Reset/Call Button – Dimensions
DWG009.2 Reset/Call Button – Wiring
DWG010 Paging Transmitter
DWG010.1 Paging Transmitter – Dimensions
DWG010.2 Paging Transmitter – Wiring
DWG011 Paging Receivers
DWG011.1 Paging Receivers – Dimensions
Installation & Commissioning Guidelines - Page 46
B N W A S
Ref: C-VIGIL/BNWAS/MANUALS/2.2 C-VIGIL Ltd : marine [email protected]
GUARDIAN APPENDIXB
ReservePowerRequirements
During normal operations the BNWAS is powered from the ship’s mains supply (86 – 265V AC 50/60Hz). In the event of a mains failure the BNWAS reverts to reserve power with no interruption of operations. Reserve power is derived from the ship’s 24V DC emergency supply. To ensure the ship’s emergency supply batteries have sufficient spare capacity please refer to the table below for typical power consumption values.
POWER CONSUMPTION TABLE
Part No: Description Total** Supply (V)
Measured Value (A) Quiescent Active
1100 HMI – User Display 1 24 240mA 240mA 1200 Main Control Unit (MCU) 1 24 300mA 300mA 1300 Manual Off & Manual Reset Panel 1 24 7mA 55mA 1400/A/--F Manual Reset Panel 7 24 7mA 55mA 1500 Paging System 1 12 3mA 73mA4 1601 Bridge Visual Alarm 1 24 4mA1 98mA1 1602 Bridge Audible Alarm 1 24 5mA2 5mA2 1603 Bridge Wing AV Alarm - Port 1 24 0 33mA3 1604 Bridge Wing AV Alarm – Stbd 1 24 0 33mA3 1605/A/--D Officers Area Cabin or Bedroom Alarms 4 24 0 30mA 1606/A/--J Public Room Alarm(s) 10 24 0 30mA 1701/A/--G Motion Sensors 7 12 13mA 13mA 1800 NMEA Interface 1 12 0 25mA 1900 Wireless Panic Button 1 24 9mA 63mA ** The exact number used would be in accordance with the ships operating plan agreed with the Flag Administration. 1. Min/Max illumination settings. 2. Measured when SPL set to 85dB 3. 20mA – Sounder : 13mA – Visual 4. Transmitter active for 3s every 30s till reset Example: For a typical installation comprising:
Number Fitted Description Measured
Current (mA) Total Current Consumption
1 Main Control Unit – MCU 300 300 1 User Display – HMI 240 240 1 Manual Off & Manual Reset Panel 55 55 4 Manual Reset Panels 55 220 1 Paging Transmitter 73 73 1 Bridge Visual Alarm 98 98 1 Bridge Audible Alarm 5 5 4 Cabin Alarms 30 120 4 Public Room Alarms 30 120 3 PIR Motion Sensors 13 39 1 NMEA Interface 25 25 1 Wireless Panic Button 63 63
TOTAL 1.358Amps
Installation & Commissioning Guidelines - Page 47
B N W A S
Ref: C-VIGIL/BNWAS/MANUALS/2.2 C-VIGIL Ltd : marine [email protected]
GUARDIAN To meet the required 6 hour duration on reserve power: - In this example, from the measured values, it can be seen that the total peak current consumption = 1.358Amps. Therefore the minimum reserve capacity of the emergency batteries must be: - 6 X 1.358 = 8.148AHC ((before the appropriate adjustment to allow for capacity loss over the battery lifetime).
www.bridge-watch.co.uk C-VIGIL Ltd : marine [email protected]
B N W A S C -V IG IL LTD
: m a r i n e
Drawing Register
DRAWING DWG No. DESCRIPTION: SUPPLY: REVISION:
A B C D E F DWG000 -/- Drawing Register -/- May 11 General -/- Typical Bridge PIR Deployment -/- May 11 General -/- Typical PIR Detector Patterns -/- May 11 DWG001.1 1 of 12 Overview Schematic -/- May 11 DWG001.2 2 of 12 System Interconnections Standard May 11 DWG001.3 3 of 12 System Wiring Standard May 11 DWG001.4 4 of 12 System PSU Wiring Standard May 11 DWG001.5 5 of 12 NMEA I/O Interface Standard May 11 DWG001.6 6 of 12 Autopilot/GPS I/P Standard May 11 DWG001.7 7 of 12 Additional Bridge Equipment Standard May 11 DWG001.8 8 of 12 Central Alarm I/P Standard May 11 DWG001.9 9 of 12 Mains Fail to Central Alarm O/P Standard May 11 DWG001.10 10 of 12 VDR NMEA Output Standard May 11 DWG001.11 11 of 12 Staged Alarms Audible / Visual Wiring Standard May 11 DWG001.12 12 of 12 Manual Reset/Emergency Call Wiring Standard May 11 DWG002 1 of 3 Main Terminal Strip – TB1 Standard May 11 DWG002.1 2 of 3 Main Terminal Strip – TB2 Standard May 11 DWG002.2 3 of 3 Main Terminal Strip – TB3 Standard May 11 DWG003 1 of 2 Main Control Panel Standard May 11 DWG003.1 2 of 2 Main Control Panel – Dimensions Standard May 11 DWG004 1 of 1 Main PLC Unit / IO Details Standard May 11 DWG005 1 of 3 HMI User Display Unit Standard May 11 DWG005.1 2 of 3 HMI User Display Unit – Dimensions Standard May 11 DWG005.2 3 of 3 HMI User Display – Wiring Standard May 11 DWG006 1 of 3 HMI Enclosure Standard May 11 DWG006.1 2 of 3 HMI Enclosure - Dimensions Standard May 11 DWG006.2 3 of 3 HMI Enclosure - Internal Standard May 11
www.bridge-watch.co.uk C-VIGIL Ltd : marine [email protected]
B N W A S C -V IG IL LTD
: m a r i n e
DRAWING DWG No. DESCRIPTION: SUPPLY: A B C D E F
DWG007 1 of 3 Directional PIRs Standard May 11 DWG007.1 2 of 3 Directional PIRs – Dimensions Standard May 11 DWG007.2 3 of 3 Directional PIR – Wiring Standard May 11 DWG008 1 of 3 Norm/Off & Reset/Emgy Call Panel Standard May 11 DWG008.1 2 of 3 Norm/Off & Reset/Emgy Call Panel – Dimensions Standard May 11 DWG008.2 3 of 3 Norm/Off & Reset/Emgy Call Panel – Wiring Standard May 11 DWG009 1 of 3 Reset/Emgy Call Panel Standard May 11 DWG009.1 2 of 3 Reset/Emgy Call Panel – Dimensions Standard May 11 DWG009.2 3 of 3 Reset/Emgy Call Panel – Wiring Standard May 11 DWG010 1 of 3 Paging Transmitter Standard May 11 DWG010.1 2 of 3 Paging Transmitter – Dimensions Standard May 11 DWG010.2 3 of 3 Paging Transmitter – Wiring Standard May 11 DWG011 1 of 2 Paging Receivers Standard May 11 DWG011.1 2 of 2 Paging Receivers – Dimensions Standard May 11 DWG012 1 of 3 Bridge Sounder Standard May 11 DWG012.1 2 of 3 Bridge Sounder – Dimensions Standard May 11 DWG012.2 3 of 3 Bridge Sounder – Wiring Standard May 11 DWG013 1 of 3 Bridge Beacon Standard May 11 DWG013.1 2 of 3 Bridge Beacon – Dimension Standard May 11 DWG013.2 3 of 3 Bridge Beacon – Wiring Standard May 11 DWG014 1 of 3 Cabin & Public Room AV Units Standard May 11 DWG014.1 2 of 3 Cabin & Public Room AV Units – Dimensions Standard May 11 DWG014.2 3 of 3 Cabin & Public Room AV Units – Wiring Standard May 11 DWG015 1 of 3 Cabin Bedroom Sounder Optional May 11 DWG015.1 2 of 3 Cabin & Bedroom Sounder – Dimensions Optional May 11 DWG015.2 3 of 3 Cabin & Bedroom Sounder – Wiring Optional May 11 DWG016 1 of 3 Wireless Panic Button Optional May 11 DWG016.1 2 of 3 Wireless Panic Button – Dimensions Optional May 11 DWG016.2 3 of 3 Wireless Panic Button – Wiring Optional May 11 Parts -/- Parts List -/-
E: [email protected] T: +44 (0)1246 269 469
W: www.bridge-watch.co.uk
GUARDIAN---------- Bridge Navigation Watch Alarm System (BWNAS)
GUARDIAN : Typical Bridge Layout
Bridge Centre Console
Chart Table
Toilet
Lock
er
Radar No 1
Radar No 2
Exit
Communications Centre
Black-out Curtain
Bridge F’rd Console
= PIR Motion Sensors
E: [email protected] T: +44 (0)1246 269 469
W: www.bridge-watch.co.uk
GUARDIAN---------- Bridge Navigation Watch Alarm System (BNWAS)
GUARDIAN : Typical Detection Area
Bridge Centre Console
Chart Table
Toilet
Lock
er
Radar No 1
Radar No 2
Exit
Communications Centre
Black-out Curtain
Bridge F’rd Console
= PIR Motion Sensors
Project / Vessel GUARDIAN : Bridge Navigation Watch Alarm System (BNWAS)
Wheelhouse Top
Wheelhouse / Bridge Deck 1602
Bridge Sounder
1601 Bridge Beacon
Accommodation Decks
C L
Port Stbd
1200 Main Control Panel
1.01 1.02 1.01
1.01
1.01
1.01 1.01
1.02
1.01
Ship’s Mains
24V DC
RS422 12V DC
1100 HMI Touch Screen
Display
1.02
1607 (optional) Bedroom Bedhead
Sounder
1605 (optional) Cabin
Sounder / Beacon
Capt Cabin
1607 (optional) Bedroom Bedhead
Sounder
C/O Cabin
1605 (optional) Cabin
Sounder / Beacon
2/O Cabin
1605 (optional) Cabin
Sounder / Beacon
3/O Cabin
1606 Public Room
Sounder / Beacon
Off Area
1606 (optional) Public Room
Sounder / Beacon
Off Lounge Mess
1605 (optional) Cabin
Sounder / Beacon
1.02
Ship’s Central Alarm Console (Mains Failure)
Ship’s Heading/ Track Control
System
1.02
1.01
1400 Reset / Emgy
Call Panel
Additional Reset / Emgy
Call Panel
Interface to Additional
Bridge Equip
1.02
1605 (optional) Office
Sounder / Beacon
1606 (optional) Public Room
Sounder / Beacon
Ship’s Office ECR
1605 Officers’ Area
Sounder / Beacon
Unacknowledged Nav Alarm
1701 Directional PIR
1701 Directional PIR
1701 (optional) Directional PIR
1701 (optional) Directional PIR
REVISION: F
DRAWN BY: SS
DWG No: DWG001.1
SHEET No: 1 of 12
DATE: May 2011
TITLE: Overview
C-VIGIL Ltd : marine www.bridge-watch.co.uk
SCALE:
NOT TO SCALE
VDR
1.01
1.01
$GPVTG NMEA I/P from GPS
G U A R D I A N
B N W A S
Cable Schedule
1.01 : Cat5 Ethernet UTP 1.02 : 3 core, 32/1mm, PVC
1.02 Ship’s 24V DC
Off Area
1300 Reset / Emgcy Call Norm/Off Selector
1900 (optional) Wireless Panic
Button
1500 Paging System
Tx 1501 Paging System
Rx
Rd
Project / Vessel GUARDIAN : Bridge Navigation Watch Alarm System (BNWAS)
REVISION: F
DRAWN BY: SS
DWG No: DWG001.2
SHEET No: 2 of 12
DATE: May 2011
TITLE: System Interconnections
C-VIGIL Ltd : marine www.bridge-watch.co.uk
SCALE:
NOT TO SCALE
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 U
L
F1 F2
1 2 3 4 5 6 1 2
HMI / Operator Display Main Control Panel (MCU)
Mains
1 2 3 4 5 6 1 2 3 4 5 6
1 2 3 4 5 6 1 2 3 4 5 6
1 2 3 4 5 6 1 2 3 4 5 6
1 2 3 4 5 6
PIR 1 (Directional) PIR 2 (Directional)
PIR 3 (Directional - Optional) PIR 4 (Directional - Optional)
PIR 5 (Spare) PIR 6 (Spare)
PIR 7 (Spare)
1.01
1.01 1.01
1.01 1.01
1.01 1.01
1.01
Og/
Wt
Og
Bl/
Wt
Bl
Gn/
Wt
Gn
Og/
Wt
Bl/
Wt
Gn/
Wt
Og/W
t
Og
Bl/Wt
Bl
Gn/W
t
Gn
Og/W
t
Og
Bl/Wt
Bl
Gn/W
t
Gn
Og/W
t
Og
Bl/Wt
Bl
Gn/W
t
Gn
Og/W
t
Og
Bl/Wt
Bl
Gn/W
t
Gn
Og/W
t
Og
Bl/Wt
Bl
Gn/W
t
Gn
Og/W
t
Og
Bl/Wt
Bl
Gn/W
t
Gn
Og/W
t
Og
Bl/Wt
Bl
Gn/W
t
Gn
Og
Bl
Gn
Og
Bl
Gn
Og
Bl
Gn
Og
Bl
Gn
Og
Bl
Gn
Og
Bl
Gn
Og
Bl
Gn
Og/
Wt
Bl/
Wt
Gn/
Wt
Og/
Wt
Bl/
Wt
Gn/
Wt
Og/
Wt
Bl/
Wt
Gn/
Wt
Og/
Wt
Bl/
Wt
Gn/
Wt
Og/
Wt
Bl/
Wt
Gn/
Wt
Og/
Wt
Bl/
Wt
Gn/
Wt
Tamper Loop (if required) 1.02
1.02
Og
Bl
Gn
Rd
Rd
Bk
Bk
1 2
Norm / Off & Man Reset Emgy Call
1.01
Og/W
t
Og
Bl/Wt
Bl
Gn/W
t
Gn
Gn
Og/
Wt
Bl/
Wt
Gn/
Wt
Gn/
Wt
Reset From Other Bridge Equipment
Og
Bl
Og/
Wt
Bl/
Wt
Rd
Bk
1.02
Og
Og/
Wt
Og
Og/
Wt
Og
Og/
Wt
Og
Og/
Wt
Og
Og/
Wt
Og
Og/
Wt
Og
Og/
Wt
Og
Og/Wt
Og
Og/Wt
Og
Og/Wt
Og
Og/Wt
Og
Og/Wt
Og
Og/Wt
Og
Og/Wt
1.01
1.01
1.01
1.01
1.01
1.01
1.01
2 1
Pagi
ng T
x
1 2
Og
Og/
Wt
Og
Og/Wt
1.01
Rd
Bk
1.02
1.01
G U A R D I A N
B N W A S
A B
DJ10 A B
DJ8 A B
DJ9 A B
DJ3
NMEA IO Interface (A)
$GPV
TG a
nd/o
r $_
_ALR
from
GPS
B A
D
J1
$HCH
TD a
nd/o
r $_
_ALR
or 4
-32V
DC
from
Aut
opilo
t
B A
D
J2
Mai
ns F
ail t
o
Cent
ral A
larm
B A J5
$BN
ALR
to V
DR
B A
D
J6
J7 B
A J4
$__A
LRxx
xx :T
rans
fer
Alar
m
Spare Alarm I/P
NMEA IO Interface (B) (if required)
1 2
D3 4
D5 6
D
Additional Nav Equip Inputs
To NMEA Interface A (I/P J3)
43 43
44 44
TB3
TB1
45 45
46 46
47 47
TB3**
49 50 51 53 54 55 56 57 TB3** B
k
Bk
Bk
Rd
Rd
Rd
Rd
Rd
Rd
Rd
Bk
Bk
-ve +ve
Rd
a
a
RS42
2
PIR
No
1
PIR
No
2
PIR
No
3
PIR
No
4
PIR
No
5
PIR
No
6
PIR
No
7
Tam
per L
oop
Rese
t Fro
m
Bdg
Equ
ip
Nor
m /
Off
Man
Res
et
Man
Res
et
LEDs
Bd
g Vi
s Al
m
1st S
tage
2nd S
tage
1
2nd S
tage
2
2nd S
tage
3
2nd S
tage
4
3rd S
tage
Pagi
ng T
x
Mai
ns F
ail N
C
RS23
2
$BN
ALRx
xxx
Au
topi
lot /
G
PS
Alar
m
Tran
sfer
24V
DC +
ve
0V
12V
DC +
ve
2 1
Stag
e 1
2 1
Brid
ge B
eaco
n
2 1
Stag
e 2
A/V
1
2 1
Stag
e 2
A/V
2
2 1
Stag
e 2
A/V
3
2 1
Stag
e 2
A/V
4
2 1
Stag
e 3
A/V
Man Reset / Emgy Call - Port
58
Rd
Bk
48 483 52
Bk
Pani
c Bu
tton
Re
ceiv
er
Wireless Panic Button Rx
1 2 3 4
1 2 3
Bl
1.01
Og
Og/Wt
Bl
Og
Og/
Wt
1.02
F3 F4 1.02
24V DC
Yw
Y
w
Ships Alarm Plant (if required)
Bl
Bl
Rd
Bk
Rd
Bk
Rd
Bk
Rd
Bk
Rd
Bk
Rd
Bk
Rd
Bk
Bk
Rd
Bk
Rd
Bk
Rd
Bk
Rd
Bk
Rd
Bk
Rd
1 2 3 4 1 2 3 4 1 2 3 4
Og/W
t
Og
Bl/Wt
Bl
Og/W
t
Og
Bl/Wt
Bl
Og/W
t
Og
Bl/Wt
Bl
Man Reset / Emgy Call - Stbd
Man Reset / Emgy Call - Chart
Project / Vessel GUARDIAN : Bridge Navigation Watch Alarm System (BNWAS)
10 0 1 2 3 4 5 6 7 11 12 13 14 15 16
24V DC +ve
1KR
24V OV PLC Supply
PIR
No
1
PIR
No
2
PIR
No
3
PIR
No
4
PIR
No
5
PIR
No
6
PIR
No
7
Nor
mal
/
Man
ual O
ff
Man
Res
et /
Em
gy C
all
17
PIR Anti-tamper Loop 24V +ve DC
RS422
X
Y 0
Com1
1 2 3
Com2
4 5 6 7 10 11 12 13 14 15 16 17
Com3 Com4
Mitsubishi FX3U32N PLC – 24V DC
0V 0V
0V 24V RS42
2
HMI – E1063 Brid
ge B
eaco
n
1st S
tage
2nd
Stag
e 1
2nd
Stag
e 2
2nd
Stag
e 3
2nd
Stag
e 4
Man
Res
et L
ED
Dim
med
Pagi
ng T
x
2A
No 1 No 2 No 6 No 7 No 3 No 4 No 5
From 12V DC +ve PSU
PIR Power Supply F8
REVISION: F
DRAWN BY: SS
DWG No: DWG001.3
SHEET No: 3 of 12
DATE: May 2011
TITLE: System Wiring
C-VIGIL Ltd : marine www.bridge-watch.co.uk
SCALE:
NOT TO SCALE
Oth
er B
dg
Equi
p
3rd S
tage
PIR No 7 PIR No 6 PIR No 5
To/From NMEA IO Interface
Mai
ns F
ail N
O/C
$GPV
TGxx
xx
from
GPS
$H
CHTD
xxxx
Fr
om A
utop
ilot
Auto
pilo
t G
PS
Una
ck N
av
Alar
m I/
P
G U A R D I A N
B N W A S
RS232
NMEA IO Interface
40
31 32 33 34 35 36 37 30
1 2 3 4
48 51
5 8 11 14 17 20 23
5 8 11 14 17 20 23
7 10 13 16 19 22 25
6 PIR No 1 PIR No 2 PIR No 3 PIR No 4
9 12 15
26 24 21
18
26
Anti-tamper Loop (If Required)
27
Tam
per
28 29
Norm Off
38
38
39
39
R(b)
41 42
434
44 45
$BN
ALRx
xxx
To V
DR
46
Mai
ns F
ail N
/O
56 54
Paging Tx
NC
C
54 57
0V
12
V DC
+ve
From NMEA IO Interface
Mai
ns F
ail
15KR
Man
Res
et L
ED
Full
53 48
Panic Button Rx
Cool
ing
Vent
Fa
n
48
Pani
c Bu
tton
Re
ceiv
er
F3
24V
DC F
ail
Vent Fan
S/S
40
47
$xxA
LR T
rans
fer
Alar
m
R(a)
PIR
- Dire
ctio
nal
PIR
- Dire
ctio
nal
PIR
- Opt
iona
l
PIR
- Opt
iona
l
PIR
- Spa
re
PIR
- Spa
re
PIR
- Spa
re
F6 2A
Reference
1 58
Refers to Main Terminal I/O Connections
TB3 F6
Refers to Main Terminal I/O Connections
TB2
F8
31 32 33 34 35 36 37 30
434
44 45 46 54 57 47
7 10 13 16 19 22 25 27 28 29 41 42 48
2A
F7
Project / Vessel GUARDIAN : Bridge Navigation Watch Alarm System (BNWAS)
5KR
Power On
24V DC +ve
12V DC +ve
0V
REVISION: F
DRAWN BY: SS
DWG No: DWG001.4
SHEET No: 4 of 12
DATE: May 2011
TITLE: System PSU Wiring
C-VIGIL Ltd : marine www.bridge-watch.co.uk
SCALE:
NOT TO SCALE
G U A R D I A N
B N W A S
Reference
39
Refers to Main Terminal I/O Connections
TB3
39
Ship
s M
ains
85
– 26
5V A
C
L
N
E
F1 2A
R1
R1(a) (supply failure relay)
To NMEA I/O Interface
R1(b) (supply failure relay)
PLC I/P X011
39 39
Ships 24V DC
PLC I/P X017
-ve
+ve
+ + - - AC AC
Siemens LOGO! PSU 86 – 265V AC / 24V DC
4A
+ - DC +ve
DC -ve
Mascot PSU 24V DC / 12V DC
6A
F2 2A
F3 4A
F4 4A
F5 4A
Project / Vessel GUARDIAN : Bridge Navigation Watch Alarm System (BNWAS)
REVISION: F
DRAWN BY: SS
DWG No: DWG001.5
SHEET No: 5 of 12
DATE: May 2011
TITLE: NMEA IO Interface
C-VIGIL Ltd : marine www.bridge-watch.co.uk
SCALE:
NOT TO SCALE
G U A R D I A N
B N W A S
PCB Layout
NMEA Interface Connections
J1 A (Rd) : TB3 43L J6 A (Rd) : TB3 46L B (Bk) : TB3 43U B (Bk) : TB3 46U
J2 A (Rd) : TB3 44L J7 A (Rd) : TB3 57 B (Bk) : TB3 44U B (Bk) : TB3 54
J3 A (Rd) : Spare I/P J8 A (Rd) : TB3 41L B (Bk) : Spare I/P B (Bk) : TB3 41U
J4 A (Rd) : TB3 47L J9 A (Rd) : TB3 42L B (Bk) : TB3 47U B (Bk) : TB3 42U
J5 A (Rd) : TB3 45L J10 A (Rd) : TB3 40L B (Bk) : TB3 45U B (Bk) : TB3 40U
Interface Schematic
NMEA Interface I/O J1: (Input) GPS $GPVTGxxxx and/or $GPALRxxxx J6: (Output) VDR - $BNALR xxxx J2: (Input) Hdg $HEHTDxxxx and/or $HEALRxxxx J7: (Input) 12V DC Supply from TB3 J3: (Input) Unack Nav Alarm - $__ALRxxxx J8: (Output) Unack Nav Alarm N/O to PLC J4: (Input) Unack Nav Alarm - Spare J9: (Output) Autopilot / GPS N/O to PLC J5: (Output) Mains fail N/O Contact J10: (Input) $BNALRxxxx sentence from PLC
Project / Vessel GUARDIAN : Bridge Navigation Watch Alarm System (BNWAS)
SCALE:
NOT TO SCALE
TITLE: Autopilot / GPS Input
C-VIGIL Ltd : marine www.bridge-watch.co.uk
SHEET No:
6 of 12
DWG. No: DWG001.6
DATE: May 2011
REVISION: F
DRAWN BY: SS
To Main Control Panel – TB3
Autopilot Selector - Heading / Track Control
1.02
Rd
Bk
Rd
Bk
G U A R D I A N
B N W A S
To Main Control Panel – TB3
GPS
1.02
Rd
Bk
Rd
Bk
Terminal No: Signal: Heading Control
MCU
? ? TB3 : 44L J2A $HEHTDxxxx and/or $HEALRxxxx / 4-32V DC ? ? TB3 : 44U J2B 0V
Cable: Type: 1.02 3 core, 32/1mm, PVC
Autopilot
Control Panel
Terminal No: Signal: GPS MCU
? ? TB3 : 43L J1A $GPVTGxxxx and/or $GPALRxxxx ? ? TB3 : 43U J1B 0V
Cable: Type: 1.02 3 core, 32/1mm, PVC
GPS
Control Panel
Project / Vessel GUARDIAN : Bridge Navigation Watch Alarm System (BNWAS)
SCALE:
NOT TO SCALE
TITLE: Additional Bridge Equipment Reset I/P
C-VIGIL Ltd : marine www.bridge-watch.co.uk
SHEET No:
7 of 12
DWG. No: DWG001.7
DATE: May 2011
REVISION: F
DRAWN BY: SS
To Main Control Panel – TB3
Reset From Additional Bridge Equipment
1.02
Rd
Bk
Rd
Bk
Terminal No: Signal: Nav
Bridge Equip
MCU
? ? TB3 : 27L N/O : Contact ? ? TB3 : 27U Common
Cable: Type: 1.02 3 core, 32/1mm, PVC
Bridge Equipment
Control Panel
G U A R D I A N
B N W A S
Project / Vessel GUARDIAN : Bridge Navigation Watch Alarm System (BNWAS)
SCALE:
NOT TO SCALE
TITLE: Un-Ack Nav Alarm Transfer Input
C-VIGIL Ltd : marine www.bridge-watch.co.uk
SHEET No:
8 of 12
DWG. No: DWG001.8
DATE: May 2011
REVISION: F
DRAWN BY: SS
To Main Control Panel – TB3
Bridge Nav Equipment
1.02
Rd
Bk
Rd
Bk
Terminal No: Signal: Nav
Equip MCU
? ? TB3 : 47L J4A $__ALRxxxx (NMEA) ? ? TB3 : 47U J4B 0V
Cable: Type: 1.02 3 core, 32/1mm, PVC
Bridge Nav Equip
Control Panel
G U A R D I A N
B N W A S
Project / Vessel GUARDIAN : Bridge Navigation Watch Alarm System (BNWAS)
SCALE:
NOT TO SCALE
TITLE: Mains Fail to Central Alarm
C-VIGIL Ltd : marine www.bridge-watch.co.uk
SHEET No:
9 of 12
DWG. No: DWG001.9
DATE: May 2011
REVISION: F
DRAWN BY: SS
To Main Control Panel – TB3
Mains Fail to Central Alarm System
1.02
Rd
Bk
Rd
Bk
Terminal No: Signal: Central Alarm Input
MCU
? ? TB3 : 45L J5A N/O : Contact ? ? TB3 : 45U J5B Common
Cable: Type: 1.02 3 core, 32/1mm, PVC
Central Alarm System
Control Panel
G U A R D I A N
B N W A S
Terminal No: Signal: VDR
MCU
? ? TB3 : 46L J6A $BNALRxxxx (NMEA) ? ? TB3 : 46U J6B 0V
Cable: Type: 1.02 3 core, 32/1mm, PVC
Project / Vessel GUARDIAN : Bridge Navigation Watch Alarm System (BNWAS)
SCALE:
NOT TO SCALE
TITLE: Output to VDR
C-VIGIL Ltd : marine www.bridge-watch.co.uk
SHEET No:
10 of 12
DWG. No: DWG001.10
DATE: May 2011
REVISION: F
DRAWN BY: SS
To Main Control Panel – TB3
VDR
1.02
Rd
Bk
Rd
Bk
G U A R D I A N
B N W A S
$ B N A L R , , 0 0 0 , A , V , C 1 = A U T ; C 2 = 3 ; C 3 = 0 * h h < C R > < L F > $ = Start of sentence BN = Equipment identifier (BN = BNWAS) ALR = Sentence type (ALR = Alarm) 000 = Designation of source alarm (000 = Automatic) A = A = Dormant period exceeded V = Dormant period not exceeded V = A = Alarm acknowledged V = Alarm unacknowledged C1 = AUT or MAN or OFF C2 = Dormant period in mins (3-12) C3 = Alarm stage 0, 1, 2 or 3 (0 = normal, 1 = 1st stage…etc) * = End of sentence
hh = Checksum <CR> = Carriage Return
<LF> = Line Feed
VDR
Control Panel
Project / Vessel GUARDIAN : Bridge Navigation Watch Alarm System (BNWAS)
SCALE:
NOT TO SCALE
TITLE: Staged Alarms Audible / Visual Wiring
C-VIGIL Ltd : marine www.bridge-watch.co.uk
SHEET No:
11 of 12
DWG. No: DWG001.11
DATE: May 2011
REVISION: F
DRAWN BY: SS
Main Control Panel
2nd Stage A/V Cabin 2 (Day Room)
**2nd Stage A/V Cabin 2 (Bed Room)
Og
Og/Wt
Og
Og/Wt
1.01
2nd Stage A/V Cabin 3
Og
Og/Wt 1.01
1.01
1.01
2nd Stage A/V Cabin 4
Og
Og/Wt 1.01
1.01 1.01 1.01 1.01
Bridge Beacon
1st Stage Sounder
1.01
1.01
1.01 1.01 1.01
**3rd Stage A/V Public Room 2
**3rd Stage A/V Public Room 3
3rd Stage A/V Public Room 1
1.01 1.01
1.01
1.01
1.01
** Optional Supply 3rd Stage A/V Alarms To cover all Officers’ public rooms
**2nd Stage A/V Cabin 1 (Day Room)
**2nd Stage A/V Cabin 1 (Bed Room)
Og
Og/Wt
2nd Stage A/V Cabin 1 (Office)
G U A R D I A N
B N W A S
TB3
: 31L
TB
3 : 3
1U
Og
Og/
Wt
TB3
: 32L
TB
3 : 3
2U
Og
Og/
Wt
TB3
: 33L
TB
3 : 3
3U
Og
Og/
Wt
TB3
: 34L
TB
3 : 4
1U
Og
Og/
Wt
TB3
: 35L
TB
3 : 3
5U
Og
Og/
Wt
TB3
: 36L
TB
3 : 3
6U
Og
Og/
Wt
TB3
: 37L
TB
3 : 3
7U
Og
Og/
Wt
Og
Og/Wt
Og
Og/Wt
Og
Og/Wt
Og
Og/Wt
Og
Og/Wt
Og
Og/Wt
Og
Og/Wt
**3rd Stage A/V Public Room (as required)
Project / Vessel GUARDIAN : Bridge Navigation Watch Alarm System (BNWAS)
SCALE:
NOT TO SCALE
TITLE: Manual Reset/Emgy Call Wiring
C-VIGIL Ltd : marine www.bridge-watch.co.uk
SHEET No:
12 of 12
DWG. No: DWG001.12
DATE: May 2011
REVISION: F
DRAWN BY: SS
Main Control Panel
TB3
: 30L
TB
3 : 3
0U
TB3
: 29U
TB
3 : 2
9L
1.01
1.01
1.01
1.01
J/B
Manual Reset/Call LED
Manual Reset/Call Push Button
Og
Og/Wt
Bl
Bl/Wt 1.01
1.01
Manual Reset/Call LED
Manual Reset/Call Push Button
Og
Og/Wt
Bl
Bl/Wt 1.01
1.01
Manual PB Reset LED
Manual Reset Push Button Og
Og/Wt
Bl
Bl/Wt 1.01
1.01
J/B 1 2 3 4
Og
Og/
Wt
Bl
Bl/W
t
Og
Og/
Wt
Bl
Bl/W
t
G U A R D I A N
B N W A S
Norm/Off & Man Reset/Emgy Call Panel
Man Reset/Emgy Call Panel - Port
Man Reset/Emgy Call Panel - Stbd
Manual Reset/Call LED
Manual Reset/Call Push Button
Og
Og/Wt
Bl
Bl/Wt 1.01
1.01
Man Reset/Emgy Call Panel – Chart Table
Man Reset/Emgy Call Panel – Port Wing
Bl
Bl/Wt Manual Reset/Call Push Button
1.01
Manual Reset/Call Push Button
J/B 1 2 3 4
1 2 3 4
J/B 1 2 3 4
Og
Og/Wt
1.01
Manual Reset/Call LED
Normal / Man Off Key Switch Gn
Gn/Wt
1 2
1.01
Gn
Gn/W
t
Gn
Gn/W
t
TB3
: 28U
TB
3 : 2
8L
Og
Og/
Wt
Bl
Bl/W
t
Og
Og/
Wt
Bl
Bl/W
t
Og
Og/
Wt
Bl
Bl/W
t
Additional Panels (as required)
Bl
Bl/Wt
1.01
Og
Og/Wt
1.01
Manual Reset/Call LED
Manual Reset/Call Push Button
Man Reset/Emgy Call Panel – Stbd Wing
Bl
Bl/Wt
1.01
Og
Og/Wt
1.01
Manual Reset/Call LED
Project / Vessel GUARDIAN : Bridge Navigation Watch Alarm System (BNWAS)
REVISION: F
DRAWN BY: SS
DWG No: DWG002
SHEET No: 1 of 3
DATE: May 2011
TITLE: TB1 / PSU
C-VIGIL Ltd : marine www.bridge-watch.co.uk
SCALE:
NOT TO SCALE
TB1
A
C
AC
F1 AC
F2 AC
F4 DC
F5 DC
24V
DC
In
Mai
ns In
24V
DC
Out
24V
DC
+ve
24V
DC
+ve
0V
F3 DC
-ve
-ve
+ve
+ve
24V DC In
12V DC Out
Mascot 24V DC / 12V DC PSU
SIEMENS
LOGO! Power 6EP1332-1SH51
24V ok
22.2….264V
Input AC 100 – 240V
Output DC 24V /4A
L1 N + + - -
12V PSU 24V PSU
G U A R D I A N
B N W A S
Project / Vessel GUARDIAN : Bridge Navigation Watch Alarm System (BNWAS)
TB2
1 2 3 4 F8 F7 F6
TB3
12 D
C +v
e PL
C
HMI &
Out
put W
arni
ng D
evic
es
24V
DC
+ve
from
PSU
24V
DC
+ve
from
PSU
12
V D
C +v
e fr
om P
SU
0V
Inte
rnal
Wiri
ng
Inte
rnal
Wiri
ng
Inte
rnal
Wiri
ng
0V
Inte
rnal
Wiri
ng
Inte
rnal
Wiri
ng
Vent
Fan
24V
DC
+ve
REVISION: F
DRAWN BY: SS
DWG No: DWG002.1
SHEET No: 2 of 3
DATE: May 2011
TITLE: TB2
C-VIGIL Ltd : marine www.bridge-watch.co.uk
SCALE:
NOT TO SCALE
G U A R D I A N
B N W A S
5
1KR
PIR
12V
DC
+ve
Inte
rnal
Wiri
ng
Pagi
ng T
x &
Zen
er B
arrie
r 0V
TB3
Key
Switc
h (N
/O)
K
ey S
witc
h (N
/O)
Pagi
ng T
x N/
O
Pa
ging
Tx
N/O
12V
+ ve
0V
Tam
per
Tam
per
N/O
N/O
12
V +
ve
0V
Ta
mpe
r
T
ampe
r N
/O
N/O
Ta
mpe
r Loo
p (N
/C)
Ta
mpe
r Loo
p (N
/C)
Mai
ns F
ail (
R1)
Mai
ns F
ail (
R1)
12V
+ ve
0V
Tam
per
Tam
per
N/O
N/O
12V
+ ve
0V
Tam
per
Tam
per
N/O
N/O
12V
+ ve
0VTa
mpe
r
T
ampe
r N
/O
N
/O
12V
+ ve
0V
Tam
per
Tam
per
N/O
N/O
12
V +
ve
0V
Ta
mpe
r
T
ampe
r N
/O
N
/O
Oth
er E
quip
(N/O
)
O
ther
Equ
ip (N
/O)
Rese
t PB
(N/O
)
R
eset
PB
(N/O
)Re
set P
B LE
D +
ve
R
eset
PB
LED
0VBr
idg
Beac
on +
ve
Br
idge
Bea
con
0V
Firs
t Sta
ge +
ve
Firs
t Sta
ge 0
V
Se
cond
Sta
ge 1
+ v
e
Sec
ond
Stag
e 1
0V
REVISION: F
DRAWN BY: SS
DWG No: DWG002.2
SHEET No: 3 of 3
DATE: May 2011
TITLE: TB3 – Main I/O Terminal Strip
C-VIGIL Ltd : marine www.bridge-watch.co.uk
SCALE:
NOT TO SCALE
26 27 28
RS42
2 PL
C /
HM
I
PIR
No
6
PIR
No
7
PIR
No
4
PIR
No
5
PIR
No
1
PIR
No
2
PIR
No
3
Tam
per L
oop
Man
Res
et/C
all
PB
Stag
ed A
larm
s
Upper (U)
Lower (L) Yw
Yw
Og
Og/
Wt
Bl
Bl
/Wt
51 2 3 4 36 1 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 29 30 31 32 33 34 35 37 38 39 40 41 42 43 44 45 46 50 53 54 57 49 52 56
NM
EA In
terf
ace
I/O
Nor
mal
/ M
an O
ff
Oth
er B
ridge
Equ
ip
Seco
nd S
tage
2 +
ve
S
econ
d St
age
2 0V
Seco
nd S
tage
3 +
ve
S
econ
d St
age
3 0V
Seco
nd S
tage
4 +
ve
S
econ
d St
age
4 0V
Third
Sta
ge +
ve
Third
Sta
ge 0
V
Pagi
ng T
rans
mitt
er
HM
I + v
e
Pagi
ng T
x +
ve
Man
ual R
eset
LED
s
24V
DC
+ ve
12V
DC
+ ve
0V
HM
I 0V
NM
EA I/
O +
ve
NM
EA I
/O 0
V
RS23
2 Fr
om P
LC
RS2
32 F
rom
PLC
AP
& G
PS
AP
& G
PS
Tran
sfer
Alm
T
rans
fer A
lm
$GPV
TG I
n
$G
PVTG
In
$HCH
TD I
n
$H
CHTD
In
Mai
ns F
ail N
/O
Mai
ns F
ail N
/O
$BN
ALR
Out
$BN
ALR
Out
$_
_Alr
In
$__
ALR
In
Project / Vessel GUARDIAN : Bridge Navigation Watch Alarm System (BNWAS)
58
Spar
e
47
P
anic
But
ton
Swd
12
V DC
+ve
55
Pani
c Bu
tton
Rx
Pani
c Bu
tton
Rx
0V
48
Spar
e
Spar
e
G U A R D I A N
B N W A S
Gn
Gn/
Wt
Project / Vessel GUARDIAN : Bridge Navigation Watch Alarm System (BNWAS)
Front View Left Side View Right Side View Bottom View
Supply DO NOT COVER
DO NOT COVER
REVISION: F
DRAWN BY: SS
DWG No: DWG003
SHEET No: 1 of 2
DATE: May 2011
TITLE: Main Control Panel
C-VIGIL Ltd : marine www.bridge-watch.co.uk
SCALE:
NOT TO SCALE
GUARDIAN B N W A S
C-VIGIL LTD : MARINE
BRIDGE NAVIGATION WATCH ALARM SYSTEM
G U A R D I A N
B N W A S
TB1 TB2
TB3
R1
F1 AC
F2 AC
F3 DC
F4 DC
F5 DC
SIEMENS
LOGO! Power
Mascot 24V DC / 12V DC
100 – 240V AC / 24V DC Mitsubishi FX3U – 32 : PLC
Project / Vessel GUARDIAN : Bridge Navigation Watch Alarm System (BNWAS)
REVISION: F
DRAWN BY: SS
DWG No: DWG003.1
SHEET No: 2 of 2
DATE: May 2011
TITLE: Main Control Panel - Dimensions
C-VIGIL Ltd : marine www.bridge-watch.co.uk
SCALE:
NOT TO SCALE
G U A R D I A N
B N W A S
300mm
300m
m
320m
m
210mm
420mm
DO NOT COVER
TB1 TB2
TB3
R1
F1 AC
F2 AC
F3 DC
F4 DC
F5 DC
SIEMENS
LOGO! Power
Mascot 24V DC / 12V DC
100 – 240V AC / 24V DC Mitsubishi FX3U – 32 : PLC
Project / Vessel GUARDIAN : Bridge Navigation Watch Alarm System (BNWAS)
Main PLC
. 24V X1 X3 X5 X7 X11 X13 X15 X17
E S/S 0V X0 X2 X4 X6 X10 X12 X14 X16 .
Com1 Y1 Y3 Com2 Y5 Y7 Com3 Y11 Y13 Com4 Y15 Y17
Y0 Y2 . Y4 Y6 . Y10 Y12 . Y14 Y16 .
1 2 3 4 5 6 7
10 11 12 13 14 15
0
17 16
1 2 3 4 5 6 7
10 11 12 13 14 15
0
17 16
Power
Run
Batt
Error
In
Out
24V DC
I/O Table
Power Supplies
Inputs
Outputs
24V + 24V DC +ve 24V - 0V S/S 0V 0V N/C
24V N/C X0 PIR No 1 - Directional X1 PIR No 2 – Directional X2 PIR No 3 – Directional (optional) X3 PIR No 4 – Directional (optional) X4 PIR No 5 - Spare X5 PIR No 7 – Spare X6 PIR No 8 – Spare X7 Tamper Detection
X10 Other Bridge Equip – Reset X11 Ships Mains Supply Fail X12 Normal / Isolated X13 Manual Reset / Call Button X14 Autopilot/GPS X15 Unack Nav Alarm (Alarm Transfer) X16 Wireless Panic Button Receiver X17 Ships 24V DC Supply Fail
Com1 Common : 24V +ve Y0 Bridge Beacon Y1 1st Stage (Bridge Sounder) Y2 2nd Stage No 1 (Accom Alarm) Y3 2nd Stage No 2 (Accom Alarm)
Com2 Common : 24V +ve Y4 2nd Stage No 3 (Accom Alarm) Y5 2nd Stage No 4 (Accom Alarm) Y6 3rd Stage (Public Room Alarm) Y7 Man Reset Buttons - LED Dimmed
Com3 Common : 24V +ve Y10 Man Reset Buttons - LED Full Y11 Not Used Y12 Not Used Y13 Not Used
Com4 Common Y14 Paging Transmitter Y15 Not Used Y16 Not Used Y17 Not Used
REVISION:
F
DRAWN BY: SS
DWG No: DWG004
SHEET No: 1 of 1
DATE: May 2011
TITLE: Main PLC I/O
C-VIGIL Ltd : marine www.bridge-watch.co.uk
SCALE:
NOT TO SCALE
G U A R D I A N
B N W A S
RS232
Stop
RS422
Run
Project / Vessel GUARDIAN : Bridge Navigation Watch Alarm System (BNWAS)
Front
Expansion
1
MO
DE
+ - E 24V D
C
COM
2 RS232
COM
1 RS422 RS485
Rear
Side
REVISION: F
DRAWN BY: SS
DWG No: DWG005
SHEET No: 1 of 3
DATE: May 2011
TITLE: HMI User Display
C-VIGIL Ltd : marine www.bridge-watch.co.uk
SCALE:
NOT TO SCALE
G U A R D I A N
B N W A S
GUARDIAN - BNWAS
Project / Vessel GUARDIAN : Bridge Navigation Watch Alarm System (BNWAS)
REVISION: F
DRAWN BY: SS
DWG No: DWG005.1
SHEET No: 2 of 3
DATE: May 2011
TITLE: HMI User Display - Dimensions
C-VIGIL Ltd : marine www.bridge-watch.co.uk
SCALE:
NOT TO SCALE
201mm 57mm
152m
m
G U A R D I A N
B N W A S
GUARDIAN - BNWAS
Project / Vessel GUARDIAN : Bridge Navigation Watch Alarm System (BNWAS)
HMI to Main Control Panel 24V DC Power
Terminal No. Signal: HMI
Display MCU
1 TB3 : 49 24V DC +ve 2 TB3 : 52 0V E Earth Earth
Cable: Type: 1.02 3 core, 32/1mm, PVC
1
2
E
7
4
3
16 2
1
2
15 5
3
12
7 1.02
1 2
1
To HMI Touch Screen Display
To Main Control Panel
3 16 12 7 15 2
+5V
+5V
0V
0V
Mini – DIN Cover
25 way D-Sub Cover
20
21 4
17
13
8
1K 1K
Comms Cable (1.01)
HMI Unit PLC Pin No Signal Signal Direction Pin No Signal Signal Direction
2 TxD+ (Bl) Output 2 RxD+ (Wt) Input 15 TxD- (Bl/Wt) Output 1 RxD- (Bk) Input 3 RxD+ (Og) Input 7 TxD+ (Gn) Output
16 RxD- (Og/Wt) Input 4 TxD- (Yw) Output 4 RTS+
17 RTS- 5 CLS+
18 CLS- 20 1) 21 1) 6 Do not use
19 Do not use 7 0V (Gn) Output 3 OV (Rd) Input
12 +5V (Gn/Wt) Output 5 +5V (Pl) Input Cable: Type: 1.01 Cat5 ethernet, UTP
1) Pin No 20 connected to Pin No 21 internal in the terminal
RS422 HMI to Main Control Panel Comms Connection
2
3
Mini DIN – Male (PLC Unit)
25 p
in D
-sub
– M
ale
– (H
MI U
nit)
7
2 1
3 4 5
6 8
13
12
11
10
9
8
7
6
5
2
1
4
3
25
24
23
22
21
20
19
18
17
14
16
15
SCALE:
NOT TO SCALE
TITLE: HMI User Display - Wiring
C-VIGIL Ltd : marine www.bridge-watch.co.uk
SHEET No:
3 of 3
DWG. No: DWG005.2
DATE: May 2011
REVISION: F
DRAWN BY: SS
G U A R D I A N
B N W A S
Gn
Yw Wt
Bk Pl
Rd
Og
Og/WtBl
Bl/WtGn
Gn/Wt1.01
7 4 2 1 5
Project / Vessel GUARDIAN : Bridge Navigation Watch Alarm System (BNWAS)
REVISION: F
DRAWN BY: SS
DWG No: DWG006
SHEET No: 1 of 3
DATE: May 2011
TITLE: HMI Desktop Enclosure
C-VIGIL Ltd : marine www.bridge-watch.co.uk
SCALE:
NOT TO SCALE
G U A R D I A N
B N W A S
Cut Out
Operator Terminal
Project / Vessel GUARDIAN : Bridge Navigation Watch Alarm System (BNWAS)
REVISION: F
DRAWN BY: SS
DWG No: DWG006.1
SHEET No: 2 of 3
DATE: May 2011
TITLE: HMI Desktop Enclosure - Dimensions
C-VIGIL Ltd : marine www.bridge-watch.co.uk
SCALE:
NOT TO SCALE
130mm
180mm
250mm
184mm
73mm
35mm
Cut Out
Operator Terminal
91mm
Project / Vessel GUARDIAN : Bridge Navigation Watch Alarm System (BNWAS)
REVISION: F
DRAWN BY: SS
DWG No: DWG006.2
SHEET No: 3 of 3
DATE: May 2011
TITLE: HMI Desktop Enclosure - Internal
C-VIGIL Ltd : marine www.bridge-watch.co.uk
SCALE:
NOT TO SCALE
Expansion
1
MO
DE
+ - E 24V DC
COM
2 RS232
COM
1 RS422 RS485
Front Panel - Interior
Rear Panel - Exterior
Rear Panel - Interior
1 2
3 4
5 6
Project / Vessel GUARDIAN : Bridge Navigation Watch Alarm System (BNWAS)
REVISION: F
DRAWN BY: SS
DWG No: DWG007
SHEET No: 1 of 3
DATE: May 2011
TITLE: Directional PIRs
C-VIGIL Ltd : marine Services www.bridge-watch.co.uk
SCALE:
NOT TO SCALE
G U A R D I A N
B N W A S
Front Side
G U A R D I A N
Project / Vessel GUARDIAN : Bridge Navigation Watch Alarm System (BNWAS)
REVISION: F
DRAWN BY: SS
DWG No: DWG007.1
SHEET No: 2 of 3
DATE: May 2011
TITLE: Directional PIRs - Dimensions
C-VIGIL Ltd : marine www.bridge-watch.co.uk
SCALE:
NOT TO SCALE
G U A R D I A N
B N W A S
69mm 50mm
117m
m
G U A R D I A N
Terminal No: Signal: PIR
No 2 MCU
+Ve (Og) TB3 : 8L 12V DC +ve -Ve (Og/Wt) TB3 : 8U 0V T (Bl) TB3 : 9L Tamper T (Bl/Wt) TB3 : 9U Tamper C (Gn) TB3 : 10L Alarm : Common NC (Gn/Wt) TB3 : 10U Alarm : Contact
Cable: Type: 1.01 Cat5 ethernet, UTP
Terminal No: Signal: PIR
No 3 MCU
+Ve (Og) TB3 : 11L 12V DC +ve -Ve (Og/Wt) TB3 : 11U 0V T (Bl) TB3 : 12L Tamper T (Bl/Wt) TB3 : 12U Tamper C (Gn) TB3 : 13L Alarm : Common NC (Gn/Wt) TB3 : 13U Alarm : Contact
Cable: Type: 1.01 Cat5 ethernet, UTP
Optional
Terminal No: Signal: PIR
No 1 MCU
+Ve (Og) TB3 : 5L 12V DC +ve -Ve (Og/Wt) TB3 : 5U 0V T (Bl) TB3 : 6L Tamper T (Bl/Wt) TB3 : 6U Tamper C (Gn) TB3 : 7L Alarm : Common NC (Gn/Wt) TB3 : 7U Alarm : Contact
Cable: Type: 1.01 Cat5 ethernet, UTP
Project / Vessel GUARDIAN : Bridge Navigation Watch Alarm System (BNWAS)
SCALE:
NOT TO SCALE
TITLE: Directional PIRs - Wiring
C-VIGIL Ltd : marine www.bridge-watch.co.uk
SHEET No:
3 of 3
DWG. No: DWG007.2
DATE: May 2011
REVISION: F
DRAWN BY: SS
G U A R D I A N
B N W A S
Directional PIRs to Main Control Panel
Directional PIRs
To Main Control Panel – TB3
1.01
Og
Og/
Wt
Gn
Gn/W
t
Bl
Bl/W
t
Og
Og/
Wt
Gn
Gn/W
t
Bl
Bl/W
t
T
-
+
NC
NC
T
T
-
+
NC
NC
T
T
-
+
NC
NC
T
T
-
+
NC
NC
T
Terminal No: Signal: PIR
No 4 MCU
+Ve (Og) TB3 : 14L 12V DC +ve -Ve (Og/Wt) TB3 : 14U 0V T (Bl) TB3 : 15L Tamper T (Bl/Wt) TB3 : 15U Tamper C (Gn) TB3 : 16L Alarm : Common NC (Gn/Wt) TB3 : 16U Alarm : Contact
Cable: Type: 1.01 Cat5 ethernet, UTP
Optional
NOTE: Refer to Interconnections (DWG001.2) drawing for all PIR connections
`
Project / Vessel GUARDIAN : Bridge Navigation Watch Alarm System (BNWAS)
REVISION: F
DRAWN BY: SS
DWG No: DWG008
SHEET No: 1 of 3
DATE: May 2011
TITLE: Normal / Off & Reset / Emgy Call Panel
C-VIGIL Ltd : marine www.bridge-watch.co.uk
SCALE:
NOT TO SCALE
< 3 Seconds - RESET > 3 Seconds – EMERGENCY CALL
1 – MANUAL OFF 2 - NORMAL
C-VIGIL LTD : MARINE
MANUAL RESET EMERGENCY CALL
1
2
MODE SELECTOR
Top Underside
G U A R D I A N
B N W A S
1R5K
-ve
+ve
Base
1 2
3 4
1 2
1
2
2
1 4 3
1 2 3 4
+ -
Pus
h Bu
tton
LED
Rest
Pus
h Bu
tton
Key
Switc
h
1 2
P/B
1R5K LED
-ve
+ve
2 3
1
Key Switch
2 3
1
`
Project / Vessel GUARDIAN : Bridge Navigation Watch Alarm System (BNWAS)
REVISION: F
DRAWN BY: SS
DWG No: DWG008.1
SHEET No: 2 of 3
DATE: May 2011
TITLE: Norm / Off & Reset / Emgy Call - Dimensions
C-VIGIL Ltd : marine www.bridge-watch.co.uk
SCALE:
NOT TO SCALE
90mm
160m m
50mm
80mm
110mm
< 3 Seconds - RESET > 3 Seconds – EMERGENCY CALL
1 – MANUAL OFF 2 - NORMAL
C-VIGIL LTD : MARINE
MANUAL RESET EMERGENCY CALL
1
2
MODE SELECTOR
G U A R D I A N
B N W A S
Terminal No: Signal: Reset Panel
MCU
Reset Push Button 1 (Bl/Wt) TB3 : 30U Reset LED -ve 2 (Bl) TB3 : 30L Reset LED +ve 3 (Og) TB3 : 29L Reset Push Button : Common 4 (Og/Wt) TB3 : 29U Reset Push Button : N/O
Key Switch 1 (Gn) TB3 : 28L Manual Off – Common 2 (Gn/Wt) TB3 : 28U Manual Off – N/C
Cable: Type: 1.01 Cat5 ethernet, UTP
Project / Vessel GUARDIAN : Bridge Navigation Watch Alarm System (BNWAS)
Normal/Off & Reset/Emgy Call Panel to Main Control Panel
1
2
3
4
To Main Control Panel – TB3
Normal/Off & Reset/Emgy Call Panel
Og Og/
Wt
Bl
Bl/W
t
Gn
Gn/W
t
Og
Og/
Wt
Bl
Bl/W
t
Gn
Gn/W
t
1.01
1
2
SCALE:
NOT TO SCALE
TITLE: Normal/Off & Reset/Emgy Call - Wiring
C-VIGIL Ltd : marine www.bridge-watch.co.uk
SHEET No:
3 of 3
DWG. No: DWG008.2
DATE: May 2011
REVISION: F
DRAWN BY: SS
G U A R D I A N
B N W A S
Project / Vessel GUARDIAN : Bridge Navigation Watch Alarm System (BNWAS)
REVISION: F
DRAWN BY: SS
DWG No: DWG009
SHEET No: 1 of 3
DATE: May 2011
TITLE: Manual Reset / Emergency Call
C-VIGIL Ltd : marine www.bridge-watch.co.uk
SCALE:
NOT TO SCALE
Top Underside
G U A R D I A N
B N W A S
P/B
1R5K LED
-ve
+ve
1R5K
-ve
+ve
< 3 Seconds - RESET > 3 Seconds - EMERGENCY CALL
C-VIGIL LTD : MARINE
MANUAL RESET EMERGENCY CALL
Base
1
2
4 3 2 1
3 4
- +
Rest
Pus
h Bu
tton
Push
But
ton
LED
1 2 3 4
Project / Vessel GUARDIAN : Bridge Navigation Watch Alarm System (BNWAS)
REVISION: F
DRAWN BY: SS
DWG No: DWG009.1
SHEET No: 2 of 3
DATE: May 2011
TITLE: Manual Reset / Emergency Call - Dimensions
C-VIGIL Ltd : marine www.bridge-watch.co.uk
SCALE:
NOT TO SCALE
50mm 120mm
90m
m
110m
m
< 3 Seconds - RESET > 3 Seconds – EMERGENCY CALL
C-VIGIL LTD : MARINE
MANUAL RESET EMERGENCY CALL
G U A R D I A N
B N W A S
Terminal No: Signal: Reset Panel
MCU
1 (Bl/Wt) TB3 : 30U Reset LED -ve 2 (Bl) TB3 : 30L Reset LED +ve 3 (Og) TB3 : 29L Reset Push Button : Common 4 (Og/Wt) TB3 : 29U Reset Push Button : N/O
Cable: Type: 1.01 Cat5 ethernet, UTP
Project / Vessel GUARDIAN : Bridge Navigation Watch Alarm System (BNWAS)
Manual Reset / Emergency Call Panel to Main Control Panel
1
2
3
4
SCALE:
NOT TO SCALE
TITLE: Manual Reset / Emergency Call - Wiring
C-VIGIL Ltd : marine www.bridge-watch.co.uk
SHEET No:
3 of 3
DWG. No: DWG009.2
DATE: May 2011
REVISION: F
DRAWN BY: SS
G U A R D I A N
B N W A S
To Main Control Panel – TB3
Manual Reset / Emergency Call Panel
1.01
Og
Og/
Wt
Bl
Bl/W
t
Og
Og/
Wt
Bl
Bl/W
t
Project / Vessel GUARDIAN : Bridge Navigation Watch Alarm System (BNWAS)
Trig
ger +
ve
Trig
ger -
ve
Pow
er +
ve
Pow
er -v
e
Paging Tx Internal Paging Tx Antenna
Maker: Scope UK Model: PageTek 2 – 12V DC UHF Freq: 459.100MHz
REVISION: F
DRAWN BY: SS
DWG No: DWG010
SHEET No: 1 of 3
DATE: May 2011
TITLE: Wireless Paging Transmitter
C-VIGIL Ltd : marine www.bridge-watch.co.uk
SCALE:
NOT TO SCALE
Paging Tx
B N W A S
GUARDIAN
G U A R D I A N
B N W A S
Project / Vessel GUARDIAN : Bridge Navigation Watch Alarm System (BNWAS)
REVISION: F
DRAWN BY: SS
DWG No: DWG010.1
SHEET No: 2 of 3
DATE: May 2011
TITLE: Wireless Paging Transmitter - Dimensions
C-VIGIL Ltd : marine www.bridge-watch.co.uk
SCALE:
NOT TO SCALE
42mm 138mm
82m
m
100m
m
165m
m
16mm
B N W A S
GUARDIAN
G U A R D I A N
B N W A S
Terminal No: Signal: Paging
Tx MCU
T (Og) TB3 : 38L Trigger – N/O T (Og/Wt) TB3 : 38U Trigger - Common 1 (Rd) TB3 : 56 12V DC +ve 2 (Bk) TB3 : 54 0V
Cable: Type: 1.01 Cat5 ethernet, UTP 1.02 3 core, 32/1mm, PVC
Project / Vessel GUARDIAN : Bridge Navigation Watch Alarm System (BNWAS)
Wireless Paging Tx to Main Control Panel
T
T
1
2
SCALE:
NOT TO SCALE
TITLE: Wireless Paging Transmitter - Wiring
C-VIGIL Ltd : marine www.bridge-watch.co.uk
SHEET No:
3 of 3
DWG. No: DWG010.2
DATE: May 2011
REVISION: F
DRAWN BY: SS
G U A R D I A N
B N W A S
To Main Control Panel – TB3
Wireless Paging Tx
1.01
Rd
Bk
1.02
Rd
Bk
Og
Og/
Wt
Og
Og/
Wt
Project / Vessel GUARDIAN : Bridge Navigation Watch Alarm System (BNWAS)
1: SCOPE COMMS
GEO N8T2
Non-Hazardous Area Use
REVISION: F
DRAWN BY: SS
DWG No: DWG011
SHEET No: 1 of 2
DATE: May 2011
TITLE: Wireless Paging Receivers
C-VIGIL Ltd : marine www.bridge-watch.co.uk
SCALE:
NOT TO SCALE
G U A R D I A N
B N W A S
Br 802
Bravo 802 ATEX Rated Zone II
Hazardous Area Use
Project / Vessel GUARDIAN : Bridge Navigation Watch Alarm System (BNWAS)
REVISION: F
DRAWN BY: SS
DWG No: DWG011.1
SHEET No: 2 of 2
DATE: May 2011
TITLE: Wireless Paging Receivers - Dimensions
C-VIGIL Ltd : marine www.bridge-watch.co.uk
SCALE:
NOT TO SCALE
Br 802
1: SCOPE COMMS
42mm
58m
m
34m
m
53m
m
77mm
G U A R D I A N
B N W A S
Project / Vessel GUARDIAN : Bridge Navigation Watch Alarm System (BNWAS)
Top Underside
+ + - - S2
G U A R D I A N
B N W A S
REVISION: F
DRAWN BY: SS
DWG No: DWG012
SHEET No: 1 of 3
DATE: May 2011
TITLE: Bridge Multi-tone Sounder
C-VIGIL Ltd : marine www.bridge-watch.co.uk
SCALE:
NOT TO SCALE
G U A R D I A N
B N W A S
Project / Vessel GUARDIAN : Bridge Navigation Watch Alarm System (BNWAS)
REVISION: F
DRAWN BY: SS
DWG No: DWG012.1
SHEET No: 2 of 3
DATE: May 2011
TITLE: Bridge Multi-tone Sounder - Dimensions
C-VIGIL Ltd : marine www.bridge-watch.co.uk
SCALE:
NOT TO SCALE
63mm 85mm
85m
m
105m m
G U A R D I A N
B N W A S
G U A R D I A N
B N W A S
Terminal No: Signal: Bridge
Sounder Control Panel
1 (Og) TB3 : 32L 24V DC +ve 2 (Og/Wt) TB3 : 32U 0V
Cable: Type: 1.01 Cat5 ethernet, UTP
Project / Vessel GUARDIAN : Bridge Navigation Watch Alarm System (BNWAS)
Bridge Multi-tone Sounder to Main Control Panel
1
2
SCALE:
NOT TO SCALE
TITLE: Bridge Multi-tone Sounder - Wiring
C-VIGIL Ltd : marine www.bridge-watch.co.uk
SHEET No:
3 of 3
DWG. No: DWG012.2
DATE: May 2011
REVISION: F
DRAWN BY: SS
G U A R D I A N
B N W A S
To Main Control Panel – TB3
Bridge Multi-tone Sounder
1.01
Og
Og/
Wt
Og
Og/
Wt
Project / Vessel GUARDIAN : Bridge Navigation Watch Alarm System (BNWAS)
REVISION: F
DRAWN BY: SS
DWG No: DWG013
SHEET No: 1 of 3
DATE: May 2011
TITLE: Bridge Beacon
C-VIGIL Ltd : marine www.bridge-watch.co.uk
SCALE:
NOT TO SCALE
G U A R D I A N
B N W A S
Top Top Underside
- + +
-
- -
G U A R D I A N
B N W A S
2 1
Base
Project / Vessel GUARDIAN : Bridge Navigation Watch Alarm System (BNWAS)
REVISION: F
DRAWN BY: SS
DWG No: DWG013.1
SHEET No: 2 of 3
DATE: May 2011
TITLE: Bridge Beacon - Dimensions
C-VIGIL Ltd : marine www.bridge-watch.co.uk
SCALE:
NOT TO SCALE
85mm 85
mm
105m m
58mm
85mm
G U A R D I A N
B N W A S
G U A R D I A N
B N W A S
110mm
110m Diam
Project / Vessel GUARDIAN : Bridge Navigation Watch Alarm System (BNWAS)
Bridge Beacon to Main Control Panel
1
2
Terminal No: Signal: Bridge Beacon
MCU
1 (Og) TB3 : 31L 24V DC +ve 2 (Og/Wt) TB3 : 31U 0V
Cable: Type: 1.01 Cat5 ethernet, UIP
SCALE:
NOT TO SCALE
TITLE: Bridge Beacon - Wiring
C-VIGIL Ltd : marine www.bridge-watch.co.uk
SHEET No:
3 of 3
DWG. No: DWG013.2
DATE: May 2011
REVISION: F
DRAWN BY: SS
To Main Control Panel – TB3
Bridge Beacon
1.01
Og
Og/
Wt
G U A R D I A N
B N W A S
Og
Og/
Wt
Project / Vessel GUARDIAN : Bridge Navigation Watch Alarm System (BNWAS)
Top Underside
+ + - - S2 S3
REVISION: F
DRAWN BY: SS
DWG No: DWG014
SHEET No: 1 of 3
DATE: May 2011
TITLE: Cabin & Public Room AV Units
C-VIGIL Ltd : marine www.bridge-watch.co.uk
SCALE:
NOT TO SCALE
G U A R D I A N
B N W A S
G U A R D I A N
R E S E T O N B R I D G E
Project / Vessel GUARDIAN : Bridge Navigation Watch Alarm System (BNWAS)
REVISION: F
DRAWN BY: SS
DWG No: DWG014.1
SHEET No: 2 of 3
DATE: May 2011
TITLE: Cabin & Public Rooms AV Units - Dimensions
C-VIGIL Ltd : marine www.bridge-watch.co.uk
SCALE:
NOT TO SCALE
75mm
57mm 85mm
85m
m
105m m
G U A R D I A N
R E S E T O N B R I D G E
G U A R D I A N
B N W A S
Project / Vessel GUARDIAN : Bridge Navigation Watch Alarm System (BNWAS)
Cabin & Public Room Sounders to Main Control Panel
SCALE:
NOT TO SCALE
TITLE: Cabin & Public Room AV Units - Wiring
C-VIGIL Ltd : marine www.bridge-watch.co.uk
SHEET No:
3 of 3
DWG. No: DWG014.2
DATE: May 2011
REVISION: F
DRAWN BY: SS
To Main Control Panel – TB3
2nd Stage No 1
1.01
To Main Control Panel – TB3
2nd Stage No 2
1.01
To Main Control Panel – TB3
2nd Stage No 3
1.01
To Main Control Panel – TB3
2nd Stage No 4
1.01
To Main Control Panel – TB3
3rd Stage
1.01
G U A R D I A N
B N W A S
Og
Og/
Wt
Og
Og/
Wt
Og
Og/
Wt
Og
Og/
Wt
Og
Og/
Wt
Og
Og/
Wt
Og
Og/
Wt
Og
Og/
Wt
Og
Og/
Wt
Og
Og/
Wt
1
2
Terminal No: Signal: Stage 3
MCU
1 (Og) TB3 : 37L 24V DC +ve 2 (Og/Wt) TB3 : 37U 0V
Cable: Type: 1.01 Cat5 ethernet, UTP
1
2
Terminal No: Signal: Stage 2
No 4 MCU
1 (Og) TB3 : 36L 24V DC +ve 2 (Og/Wt) TB3 : 36U 0V
Cable: Type: 1.01 Cat5 ethernet, UTP
1
2
Terminal No: Signal: Stage 2
No 1 MCU
1 (Og) TB3 : 33L 24V DC +ve 2 (Og/Wt) TB3 : 33U 0V
Cable: Type: 1.01 Cat5 ethernet, UTP
1
2
Terminal No: Signal: Stage 2
No 2 MCU
1 (Og) TB3 : 34L 24V DC +ve 2 (Og/Wt) TB3 : 34U 0V
Cable: Type: 1.01 Cat5 ethernet, UTP
1
2
Terminal No: Signal: Stage 2
No 3 MCU
1 (Og) TB3 : 35L 24V DC +ve 2 (Og/Wt) TB3 : 35U 0V
Cable: Type: 1.01 Cat5 ethernet, UTP
Project / Vessel GUARDIAN : Bridge Navigation Watch Alarm System (BNWAS)
Top Underside
+ + - - S2 S3
REVISION: F
DRAWN BY: SS
DWG No: DWG015
SHEET No: 1 of 3
DATE: May 2011
TITLE: Bed-Room Sounder
C-VIGIL Ltd : marine www.bridge-watch.co.uk
SCALE:
NOT TO SCALE
G U A R D I A N
B N W A S
G U A R D I A N
RESET ON BRIDGE
Project / Vessel GUARDIAN : Bridge Navigation Watch Alarm System (BNWAS)
REVISION: F
DRAWN BY: SS
DWG No: DWG015.1
SHEET No: 2 of 3
DATE: May 2011
TITLE: Cabin Bedroom Sounder - Dimensions
C-VIGIL Ltd : marine www.bridge-watch.co.uk
SCALE:
NOT TO SCALE
53mm 85mm
85m
m
105m m
G U A R D I A N
B N W A S
G U A R D I A N
RESET ON BRIDGE
Project / Vessel GUARDIAN : Bridge Navigation Watch Alarm System (BNWAS)
Dayroom to Bedroom Sounders
1
2
Terminal No: Signal: Dayroom Sounder
Bedroom Sounder
1 (Og) 1 (Og) 24V DC +ve 2 (Og/Wt) 2 (Og/Wt) 0V
Cable: Type: 1.01 Cat5 ethernet, UTP
SCALE:
NOT TO SCALE
TITLE: Cabin Bedroom Sounder - Wiring
C-VIGIL Ltd : marine www.bridge-watch.co.uk
SHEET No:
3 of 3
DWG. No: DWG015.2
DATE: May 2011
REVISION: F
DRAWN BY: SS
G U A R D I A N
B N W A S
Cabin Day-room Sounder
Cabin Bedroom Sounder
1.01
Og
Og/
Wt
Og
Og/
Wt
Project / Vessel GUARDIAN : Bridge Navigation Watch Alarm System (BNWAS)
REVISION: F
DRAWN BY: SS
DWG No: DWG016
SHEET No: 1 of 3
DATE: May 2011
TITLE: Wireless Panic / Reset Button
C-VIGIL Ltd : marine www.bridge-watch.co.uk
SCALE:
NOT TO SCALE
G U A R D I A N
B N W A S
GUARDIAN B N W A S
WIRELESS PANIC BUTTON RECEIVER
C-VIGIL LTD : MARINE
Project / Vessel GUARDIAN : Bridge Navigation Watch Alarm System (BNWAS)
REVISION: F
DRAWN BY: SS
DWG No: DWG016.1
SHEET No: 2 of 3
DATE: May 2011
TITLE: Wireless Panic / Reset Button - Dimensions
C-VIGIL Ltd : marine www.bridge-watch.co.uk
SCALE:
NOT TO SCALE
G U A R D I A N
B N W A S
GUARDIAN B N W A S
WIRELESS PANIC BUTTON RECEIVER
C-VIGIL LTD : MARINE
35mm
65mm
15mm
135mm
85mm
116mm
45mm
165mm
Terminal No: Signal: Panic Button
Rx MCU
1 (Og) TB3 : 48L 24V DC +ve 2 (Og/Wt) TB3 : 48U Switched 24V DC +ve 3 (Bl) TB3 : 53 0V
Cable: Type: 1.01 Cat5 ethernet, UTP
Project / Vessel GUARDIAN : Bridge Navigation Watch Alarm System (BNWAS)
Wireless Panic / Reset Button Rx to Main Control Panel
SCALE:
NOT TO SCALE
TITLE: Wireless Panic / Reset - Wiring
C-VIGIL Ltd : marine www.bridge-watch.co.uk
SHEET No:
3 of 3
DWG. No: DWG016.2
DATE: May 2011
REVISION: F
DRAWN BY: SS
G U A R D I A N
B N W A S
Main Control Panel – TB3
Wireless Panic / Reset Button Receiver
1.01
Og
Og/
Wt
Og
Og/
Wt
1
2
3
Bl
Bl
11001101 HMI User Display Unit E1063 Mitsubishi1102 HMI Surface Mounting Panel ALU-topline Phoenix Mecano12001201 Enclosure Compact AE Rittal1202 Enclosure Mounting Brackets Compact AE Rittal1203 Door Chassis Plate -/- -/-1204 24V DC Cooling Fan OD8015-24LB Orion1205 Fan Filter RCP-80 RichCo1206 Power Indicator LED RT1027BUT Rodan1207 220V AC Power MCB 2CDS272001R0024 ABB1208 24V PSU Switch Mode Siemens1209 12V PSU Switch Mode Mascot1210 Terminals, Trunking, DIN Rail…etc Various RS1211 Mains Fail Relay -/- RS1212 Main PLC Unit FX3U32M Mitsubishi1213 HMI to PLC cable GT801-2M RS1214 RS232C Adapter FX3U-232-ADP Mitsubishi
1301 Enclosure 230.092.000 OKW1302 Key Switch SRL5LD2 Lorlin1303 Halo Ring (Blue) Push Button MPI002/28/BL Bulgin
1401 Enclosure 230.090.000 OKW1402 Halo Ring (Blue) Push Button MPI002/28/BL Bulgin
1401 Enclosure 230.090.000 OKW1402 Halo Ring (Blue) Push Button MPI002/28/BL Bulgin
1401 Enclosure 230.090.000 OKW1402 Halo Ring (Blue) Push Button MPI002/28/BL Bulgin15001501 Paging Transmitter PageTek 2 12V Goulde1502A Standard Paging Receiver GEO NT8 Goulde1502B * Standard Paging Receiver GEO NT8 Goulde1502C * Standard Paging Receiver GEO NT8 Goulde1503A ** Eex Paging Receiver Bravo 802 Goulde1503B ** Eex Paging Receiver Bravo 802 Goulde1503C ** Eex Paging Receiver Bravo 802 Goulde16001601 Bridge Flashing Beacon (Red) Unit L101L-DC-24-W-R E2S1602 Bridge Multi-tone Sounder Unit SONF1-DC-24-W E2S
PARTS LIST
HMI Operator Display
Main Control Panel
Normal / Man Off & Reset / Emgy Call Panel
Reset / Emgy Call Panel - Port
Manufacturer
Warning Devices
1400C Reset / Emgy Call Panel - Chart Table
Part No
Reset / Emgy Call Panel - Stbd
Paging System
1400B
TypeDescription
1300
1400A
B N W A SGUARDIAN
C-VIGIL Ltd : marine (Bridge-Watch),Digital House, Foxwood Rd, Chesterfield,Derbyshire, S41 9RF, UK.
T: +44 (0)1246 269 469
www.bridge-watch.co.uk C-VIGIL Ltd : marine [email protected]
1605 Deck Officers' Area A/V Unit SON4L-DC-24-W-R E2S1605A Cabin A/V Units - Capt SON4L-DC-24-W-R E2S1605B Cabin A/V Units - C/O SON4L-DC-24-W-R E2S1605C Cabin A/V Units - 2/O SON4L-DC-24-W-R E2S1605D Cabin A/V Units - 3/O SON4L-DC-24-W-R E2S1606 Public Room A/V Units - Officers' Area SON4L-DC-24-W-R E2S1606A Public Room A/V Units - Officers' Lounge/Mess SON4L-DC-24-W-R E2S1606B Public Rooms A/V Units - Ship's Office/ECR SON4L-DC-24-W-R E2S1607A Bedroom Sounder Units - Capt BHD-DC-24-W E2S1607B Bedroom Sounder Units - C/O BHD-DC-24-W E2S17001701A Directional PIR Gardscan M/QX RISCO1701B Directional PIR Gardscan M/QX RISCO1701C * Directional PIR Gardscan M/QX RISCO1701D * Directional PIR Gardscan M/QX RISCO18001801 NMEA Interface INT-NMEA-001 Eiland Comms19001901* Panic Button Receiver KeeLoq RF Solutions1902* Panic Button Key Fob Transmitter KeeLoq RF Solutions
Items Marked * are optional
Items Marked ** are optional for hazardous area use (ATEX Zone 2 rated)
Wireless Panic Button
Part No Description Type
Interfacing
PIR Motion Detectors
Manufacturer
www.bridge-watch.co.uk C-VIGIL Ltd : marine [email protected]