BRIDGE NAVIGATION WATCH ALARM SYSTEM

     

 

   

NET-LOGIC

SYSTEM OVERVIEW

+  2

Page 2: Watchkeeper Plus BNWAS

 

 

   

NET-LOGIC

[email protected]

Further general information can be found at www.watch-keeper.com

 

Page2  

+    

 

 

 

 

 

 

 

 

 

 

 

 

   

 

 

 

 

 

 

 

“Timescale for deployment”

The timescale is dependent on size of vessel and whether it is intended to carry passengers:

• All new build vessels ≥ 150gt plus all new passenger vessels built on or after 1st July 2011

• All Cargo Vessels ≥ 3000gt by 1st July 2012 plus all existing passenger vessels

• All Cargo Vessels ≥ 500gt and <3000gt by 1st July 2013

• All Cargo Vessels ≥ 150gt and <500gt by 1st July 2014

“Net-Logic”

Net-Logic specialises in the design and development of devices that simplify the installation

process and enhance overall functionality of key marine systems. The company ethos is

based on creating simple building blocks which can be added together to produce more

complex systems. The emphasis is on innovative, well designed, well engineered products

which simplify the system design process and are quick and easy to install.

WatchKeeper is perfect for new build designs but really comes into its own within the

retrofit market. Why? The system makes use of a highly fault tolerant radio frequency mesh

network, controlling information flow in and around the bridge of the vessel. The result is an

approved Bridge Navigation Watch Alarm System that allows complete system installation

and operation within a matter of hours. No other system can offer this.

Our innovative “Range Finder” determines the ideal location for each individual unit simply

and rapidly.

“Who’s watching the Watch Keeper?”

Bridge Navigation Watch Alarm System or “BNWAS” have been a class requirement on one

man operated vessels (often referred to as “Watch One Bridges”) for a number of years now.

The importance of ensuring that the Watch Keeper on the bridge is both alert and competent

to carry out their duties is of top priority. This has been recognised by IMO who has now

made BNWAS mandatory for the majority of commercial sea going vessels.

Page 3: Watchkeeper Plus BNWAS

 

 

   

NET-LOGIC

[email protected]

Further general information can be found at www.watch-keeper.com

 

Page3  

+    

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Specification

• 3 selectable Modes:

o Automatic – Activates system when vessel’s heading or track control system is

operational

o Manual On – System is continually active

o Manual Off – System is not active under any circumstance

• Operational Sequence:

o The system displays on each reset module a visual countdown to action. This is

user defined, ranging from 3min to 12mins.

3rd Stage Remote Alarm

2rd Stage Remote Audible Alarm

1st Stage Bridge Audible Alarm

Visual Indication

Tim

e D

ela

y (T

D)

TD +

0.2

5

TD +

0.5

TD +

2.0

Min

o At the end of the Time Delay (TD) all resets present a visual flashing indication warning

the watch officer that action is required.

o Bridge audible alarm is then activated along with the visual alarm to act as a final

prompt for action

o Second stage alarm is then activated in a user selectable zone (Master/ relief Officer)

and through the optional remote alarm module

o If no action is taken before the time delay has elapsed the system activates the third

stage alarm in additional crew member areas

Page 4: Watchkeeper Plus BNWAS

 

 

   

NET-LOGIC

[email protected]

Further general information can be found at www.watch-keeper.com

 

Page4  

+    

 

 

 

   

System Configuration

Key Features

• Minimal cabling requirements results in reduced vessel disruption and downtime

• Significant overall cost saving over competitor systems

• Dual functionality means fewer units on bridge; less cabling / installation / commissioning

requirements

• Simple system set-up via full colour 3.2” LCD (TFT) Touch Screen Interface

• Emergency Call Function provided by holding Master Control Unit reset button for 5 seconds

• Additional inputs from the vessel’s navigational equipment, such as the radar/ECDIS/autopilot,

allows for automatic resetting of watch alarm timer

• Optional PIR motion sensors reset the system whenever human motion is detected on the bridge

• Quick  Response  (QR)  tags  are  fitted  to  allow  instant  access  to  documentation

• Repeater  modules  can  be  used  to  boost  signal  and  extend  the  range  up  to  a  maximum  of  150m

• Net-­‐Logic  “range  finder”  is  used  to  determine  the  ideal  location  of  each  individual  unit,  allowing  

rapid  and  simple  installation  

• 24 month warranty  

Proprietary cable

2.4GHz Wireless

RS485 Wired

RF Reset Module

All wired remote modules take their power from the RS485 Data-bus. All RF remote modules require a local source of power (115/220VAC)

3rd Stage RF Audible Alarm Module (Crew

Area) RF Repeater Module*

Master Control Unit (MCU). Doubles as Reset Module and generates 1st

Stage Audible Alarm

3m pre-terminated cable

Bridge 24V DC Input

2nd Stage RF Audible Alarm Module

(Captain’s Cabin)

Alarm Interface Unit (AIU)

3rd Stage Audible Alarm Module (Public Area)

*(may be required to extend RF coverage)

Non Bridge Areas

IP66 Bridge Wing RF Reset Modules

2nd Stage RF Audible Alarm Module

(1st Officer’s Cabin)

RF PIR motion sensors

Page 5: Watchkeeper Plus BNWAS

 

 

   

NET-LOGIC

[email protected]

Further general information can be found at www.watch-keeper.com

 

Page5  

+    

 

 

   

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

   

Basic Features

• The RF options result in a rapidly expandable system requiring minimal installation time and disruption

to the vessel

• 2.4GHz RF Mesh network acts to “self heal” in unlikely event of module failure to re-route the signal to

Alarm Interface Unit (AIU)

• All RF modules have a range of approximately 30m; Repeater module can be used to boost the signal,

and may be used in series up to 4 times, giving a maximum potential range of 150m

• AIU co-ordinates the network and repeaters used to transfer the signal around the vessel

• 110/240VAC powered modules

• Reset and PIR modules all located on the bridge/ wheelhouse for normal operation

RF Modules Options

WK-AL-02A

RF Sounder Module

WK-RST-01A

RF Reset Module

WK-PIR-OA

RF PIR Motion Sensor

WK-BW_RST-A

Bridge Wing Reset Module

WK-PEX-OA

RF Repeater Module

 

Page 6: Watchkeeper Plus BNWAS

 

 

   

NET-LOGIC

[email protected]

Further general information can be found at www.watch-keeper.com

 

Page6  

+    

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

     

 

 

 

   

Basic Features

• Auto switching circuit transfers immediately between main 24VDC supply and battery backup

reserve power supply to ensure continuous system operation following power failure

• Contact closure inputs for navigation system inputs watch alarm outputs

• $__ALR output to vessel’s Voyage Data Recorder

• NMEA ALR input via IEC 61162 interface for re-transmission of unacknowledged alarms from

bridge equipment capable of sending such alarms

• Contact closure output in the event of a system fault

• Direct communication to the Master Control Unit (MCU) via 3m pre-terminated cable

• Supports up to 9 RF Resets, 9 Wired Resets, 13 RF and 13 wired Audible Alarm units

• Screw terminals for ease of connection and installation

• Enclosure dimensions: 360mm x 130mm x 90mm

Alarm Interface Unit

Dual 24VDC input from main supply and battery backup reserve supply

RS485 Communication Bus

Contact Closure input port

Master Control Unit communication port

ALR transceiver port (NMEA output to VDR & input of unacknowledged alarms

from other bridge equipment)

Contact Closure Feedback LEDs

Page 7: Watchkeeper Plus BNWAS

 

 

   

NET-LOGIC

[email protected]

Further general information can be found at www.watch-keeper.com

 

Page7  

+    

   

Basic Features

• Master Control Unit defaults to act as a Reset module with visual

countdown and system status indicators

• All inputs by the user on the touch screen will reset the timer

• 3.2” LCD touch screen

• Password protected settings via a 4 digit numerical input code

• Integral 1st Stage Audible Alarm

• Tone and volume can be adjusted during installation to within pre-

defined parameters. (75dB to 80dB range)

• Direct connection to the Alarm Interface Unit (AIU) via 3m pre-

terminated cable

• Console Mounted enclosure: 127mm x 127mm x 85mm

Master Control Unit

Touchscreen defaults to a Reset screen

Countdown LEDs indicating elapsed time

Global Brightness Control adjusts brightness

for all bridge based WatchKeeper modules

MCU has internal Alarm Sounder for 1st stage Audible

alert

Page 8: Watchkeeper Plus BNWAS

 

 

   

NET-LOGIC

[email protected]

Further general information can be found at www.watch-keeper.com

 

Page8  

+    

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Reset Modules

Basic Features

• 3 WatchKeeper Reset modules available

Piezo Switch Reset Module  

• Timer LEDs indicating elapsed time • LED feedback to indicate when reset is pressed • Piezo switch technology, ensuring zero mechanical failure and tamper proof operation • Bulkhead mounted • 16Hr battery Back-up – RF module only • Enclosure dimensions: 125mm x 125mm x 55mm

Wheelhouse PIR Motion Sensor

• LED illumination when human activity is detected • Standard field of view approx.: 1.5m range x 2m width • Module detects infra-red spectrum to eliminate non human motion triggering reset • Bulkhead mounted • Enclosure dimensions: 125mm x 125mm x 55mm

Bridge Wing Reset Module  

• IP 66 rated bridge wing Reset module • Bulkhead mounted • Piezo switch technology, ensuring zero mechanical failure and tamper proof operation • LED flashing indication when alarm is raised • Bi-colour LED indicates mains power / Battery back-up active - RF module only • Enclosure dimensions: 110mm x 110mm x 60mm

Piezo Switch Reset Module  

Wheelhouse PIR Motion Sensor

Bridge Wing Reset Module  

Page 9: Watchkeeper Plus BNWAS

 

 

   

NET-LOGIC

[email protected]

Further general information can be found at www.watch-keeper.com

 

Page9  

+  

Basic Features

• Tone and volume can be adjusted during installation to within pre-defined parameters

• Audible Output Power: o 2nd/ 3rd stage alarms >75dB and <125dB

• Status LED o Green – Normal Operation o Red – Fault Condition

• Power LED indicates whether unit is powered o Green – System powered o Solid Red – Battery Back-up

• Internal Battery Back-up ensures 24Hour operation in event of power failure – RF Module Only • Enclosure dimensions: 170mm x 170mm x 70mm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Audible Alarm Module

Mounting Brackets

Dual colour status LED:

Green – Normal Operation Solid Red – System Fault

Power Status LEDs indicate Green – Mains Operation Solid Red – Battery Back-up

Basic Features

• High Impact Plastic

• Competent crew are able to position modules in accordance with BNWAS

installation plan to ensure minimal vessel downtime

• Dimensions:

o Large: 149mm x 145mm x 62mm

o Small: 106mm x 102mm x 40mm

Sounder Module wall mount (large)

Reset/ PIR Module wall mount (small)