Technical Documentation BNWAS 3000
Tel.: +49 (0)4105 / 65 60 – 0 * DECKMA GmbH * Fax: +49 (0)4105 / 65 60 – 25 E-Mail: [email protected] * Internet: www.deckma-gmbh.de
1.6 Installation instructions Version 1.0 10.06.2013 Page 1 of 22
1.6. Installation instructions for Bridge Navigation Watch Alarm System
(BNWAS 3000)
WATCH ALARM MAIN UNIT
REPEATER UNIT SELECTOR UNIT RESET UNIT
Revisions
Version Date Author Checked Remark 1.0 10/06/13 JB TM Derived from draft 0.4
Technical Documentation BNWAS 3000
Tel.: +49 (0)4105 / 65 60 – 0 * DECKMA GmbH * Fax: +49 (0)4105 / 65 60 – 25 E-Mail: [email protected] * Internet: www.deckma-gmbh.de
1.6 Installation instructions Version 1.0 10.06.2013 Page 2 of 22
Table of contents
1. General ............................................................................................................................................. 3
2. Cable requirements .......................................................................................................................... 3
3. Connection of the various units ........................................................................................................ 4
4. Setting the address (REPEATER UNIT) .......................................................................................... 9
5. Accumulator charging....................................................................................................................... 9
6. Pin assignments ............................................................................................................................... 9
6.1. WATCH ALARM MAIN UNIT .................................................................................................... 9
6.2. REPEATER UNIT ................................................................................................................... 14
6.3. SELECTOR UNIT ................................................................................................................... 15
6.4. RESET UNIT ........................................................................................................................... 16
6.5. BOOSTER UNIT ..................................................................................................................... 17
7. Current ........................................................................................................................................... 18
8. Accumulator ................................................................................................................................... 18
9. Installation ...................................................................................................................................... 18
10. Audible signal generator ................................................................................................................ 18
11. Reset sensor .................................................................................................................................. 19
12. Location .......................................................................................................................................... 19
13. Compass safe distance .................................................................................................................. 20
14. Commissioning ............................................................................................................................... 22
Technical Documentation BNWAS 3000
Tel.: +49 (0)4105 / 65 60 – 0 * DECKMA GmbH * Fax: +49 (0)4105 / 65 60 – 25 E-Mail: [email protected] * Internet: www.deckma-gmbh.de
1.6 Installation instructions Version 1.0 10.06.2013 Page 3 of 22
1. General
These installation instructions supplement the documentation of the BNWAS (system description, operating instructions, technical documentation...). For further information, see the relevant documentation.
The currently applicable standards must be consulted prior to installation of the BNWAS and observed.
2. Cable requirements
For safe operation of the entire system, the cables shown in the table are recommended.
Connector Cable type Core diameter Cable diameter
Power supply 100-240 V AC (JM2)
Unshielded cable min. 3 x 1.5 mm²
Power supply 24 V DC (JM1)
Unshielded cable min. 3 x 2.5 mm²
Accumulator 24 V (JB1)
Shielded cable 2 x 2.5 mm²
REPEATER UNIT (JR1, JR2)
Shielded twisted-pair cable 3 x 2 x 0.75 mm²
RESET UNIT (JQ1) Shielded twisted-pair cable min. 2 x 2 x 0.75 mm² 1 5-10mm SERIAL OUT 1 (JV1) Shielded twisted-pair cable 3 x 0.75 mm² SERIAL OUT 2 (JV2) Shielded standard serial cable SERIAL IN 1 (JG1) Shielded twisted-pair cable 5 x 0.75 mm² SERIAL IN 2 (JA1) Shielded twisted-pair cable 5 x 0.75 mm² RESET SENSOR (JE1)
Unshielded cable min. 4 x 0.75 mm² 2
Relay output (JK1) Unshielded cable min. 9 x 1.0 mm² 3 AUTO MODE ON/OFF; ext. signal generator (JPI1)
Unshielded cable 5 x 0.75 mm²
1 Cable diameter depends on cable length and number of UNITS. 2 Cable diameter depends on current and voltage. 3 Cable diameter depends on connected siren, current and voltage.
Technical Documentation BNWAS 3000
Tel.: +49 (0)4105 / 65 60 – 0 * DECKMA GmbH * Fax: +49 (0)4105 / 65 60 – 25 E-Mail: [email protected] * Internet: www.deckma-gmbh.de
1.6 Installation instructions Version 1.0 10.06.2013 Page 4 of 22
3. Connection of the various units
DECKMA GMBH
mains-control Accu-cont rol
RTC
BNWAS3000 RPU-E
RS485
24V - 5V
RS485
Mikrocontroller
Beeper
115/230 - 24V
In ext. reset3x out-control
REPEATER UNIT BOOSTER UNIT
RE
SE
T
UN
IT
SE
RIA
L O
UT
1/2
SE
RIA
L IN
2
RE
SE
T
SE
NS
OR
RE
PE
AT
ER
U
NIT
Po
wer
sup
ply
100-
240
V A
C
Po
wer
sup
ply
24 V
DC
Acc
um
ula
tor
24 V
Rel
ay
outp
ut
WA
TC
H A
LAR
MM
AIN
UN
IT
RE
SE
T
UN
ITS
24V - 5V
24V - 12V
24V - 5V
SELECTOR UNIT
WA
TC
H A
LAR
MM
AIN
UN
IT
RE
PE
ATE
R
UN
ITS
Status-LED
JM1JM2 JB1
JR1
JG1 JA1 JE1JK1
JM1
JM1
JQ1
JR11
JR12
JR13
JR14
JQ1
JQ40
JR1
WACHT ALARM MAIN UNIT BNWAS3000 MU-E
BNWAS3000 BU-E
BNWAS3000 SU-E
Beeper
24V - 12V
DECKMA GMBH
RS485
24V - 5V
DECKMA GMBH
WA
TCH
ALA
RM
MA
IN U
NIT
RESET
UNIT
WA
TC
H A
LAR
MM
AIN
UN
IT
JQ1
BNWAS3000 RSU-E
DECKMA GMBH
Ext. BeeperAuto on/off
JP1
AU
TO
MO
DE
O
N/O
FF
; ext
. S
igna
l ge
nera
tor
24V - 5V
RS485RS485
24V - 5V
JR2
JV1
JV2
JR1
Mikrocontro ller Mikrocontroller
SE
RIA
L IN
1
Po
wer
sup
ply
24
V D
C
Pow
er
supp
ly
24 V
DC
Technical Documentation BNWAS 3000
Tel.: +49 (0)4105 / 65 60 – 0 * DECKMA GmbH * Fax: +49 (0)4105 / 65 60 – 25 E-Mail: [email protected] * Internet: www.deckma-gmbh.de
1.6 Installation instructions Version 1.0 10.06.2013 Page 5 of 22
rt
sw
RS485-ARS485-B
BP
1234
SERIAL OUT 1
BM
Überarbeitet MP / 04.03.13
SC ASC B
JB1
123 Power supply
24 V in JM1
K3 CMK3 NC
K2 CMK2 NCK3 NO
K1 NCK2 NO
K1 NOK1 CM
123456789
Relay output
JK1
bl
br
Time/date in,
Reset, Emergency Alarm
Via RS323 or RS485
1
2
3
4
5
6
7
8
9 SERIAL OUT 2
Time/date in,
Reset, Emergency Alarm
Via RS323 or RS485
JV2
JV1
PC, VDR,
Gerneralalarm...
1234
SERIAL
Wiring diagram BNWAS 3000 withoutSELECTOR UNIT
1
2
3
4
5
6
7
8
9SERIAL
GND
TXD
RS485-BRS485-A
PE
123456
SERIAL IN 1
RXDPE
TXD
RXD
GND
GND
24 V DC
JG1
GND
TXD
PE
RS485-ARS485-B
123456
SERIAL IN 2
PERXD JA1
GND
PE
24 V DC power supply
123
100-240 V AC
gr/ge
rt
sw
General alarm,
Signal generator...
Netzgr/ge
123 Power supply
L inN in
12345
Accumulator 24 V
+-12 V 7Ah
+-12V 7Ah
Akku 24V
7,5A
JM2
R1
Technical Documentation BNWAS 3000
Tel.: +49 (0)4105 / 65 60 – 0 * DECKMA GmbH * Fax: +49 (0)4105 / 65 60 – 25 E-Mail: [email protected] * Internet: www.deckma-gmbh.de
1.6 Installation instructions Version 1.0 10.06.2013 Page 6 of 22
12345AUTO MODE ON/OFF;
JPI1
LED out24V out
gn
gn
2
1
PZSignal
gn
gn
24V out
RS485-BRS485-A
12345
REPEATER UNIT
JR1
WATCH ALARM MAIN UNIT
SIGNAL out
3x max
PE
ADR 0
JM1
JQ40
RS485-A
1234
MU
JQ1
BOOSTER UNIT
ADR 1
RESET out
24V in
GND
LED in
AS WAP
RS485-B
GND
optional
AUTO in
GND24 V in
1234
RSU
ADR 0
PE
AS WAPADR 1
RS485-A
GNDRS485-B
24 V in
ADR 0
PE
AS WAPADR 1
RS485-A
24 V inGNDRS485-B
PE
1234
RESET UNIT
REPEATER UNIT 4
GND
12345678
WATCH ALARM MAIN UNIT
RS485-A
ADR 0
PE
AS WAPADR 1
24 V inGNDRS485-B
ext. Signal generator
24 V out
24V out
REPEATER UNIT 3
12345678
WATCH ALARM MAIN UNIT
40x max1234
MU
JQ1
RESET UNIT
LED out
JR2
LED in
REPEATER UNIT 2
RESET out
12345678
WATCH ALARM MAIN UNIT
GND
REPEATER UNIT 1
12345678
WATCH ALARM MAIN UNIT
1234
MU
24V in
RESET outLED in
GND
GND
12
JQ1 JQ1
RESET UNIT
24V in
24V ext.GND
RESET in
RESET in
JE1
ws
br
GND
ge
br
ge
ws
br
ge
ws
24V
br
ge
ws
GND
br
ge
ws
RESET inSABOT in
GND12V out
1234
RESET SENSOR
Sabotage Reset SensorikReset Reset Sensorik
24 V DCPower supply
Technical Documentation BNWAS 3000
Tel.: +49 (0)4105 / 65 60 – 0 * DECKMA GmbH * Fax: +49 (0)4105 / 65 60 – 25 E-Mail: [email protected] * Internet: www.deckma-gmbh.de
1.6 Installation instructions Version 1.0 10.06.2013 Page 7 of 22
rt
sw
RS485-A
BP
RS485-B1234
SERIAL OUT 1
BM
Wiring diagram BNWAS 3000 withSELECTOR UNIT
SC ASC B
JB1
123 Power supply
24 V inJM1
K3 CMK3 NC
K2 NCK3 NO
K2 CMK2 NOK1 NC
K1 NOK1 CM
123456789
Relay output
JK1
bl
br
1
2
3
4
5
6
7
8
9 SERIAL OUT 2
JV2
JV1
PC, VDR,
Gerneral alarm...
1234
SERIAL
1
2
3
4
5
6
7
8
9SERIAL
GND
RS485-A
PE
TXD
RS485-B
123456
SERIAL IN 1
RXD
TXD
PE
RXD
GND
Time/date in,
Reset, Emergency Alarm
Via RS323 or RS485
GND
JG1
24 V DCPEGND
RS485-ARS485-B
TXD
123456
SERIAL IN 2
RXD
GND
PEJA1
PE
24 V DC power supply
123
100-240 V AC
rt
gr/ge
sw
Netz
General alarm,
Signal generator...
gr/ge
123 Power supply
N inL in
12345
Accumulator 24 V
+-12 V 7Ah
+-12V 7Ah
Akku 24V
JM2
7,5A1
Time/date in,
Reset, Emergency Alarm
Via RS323 or RS485
R2
Überarbeitet MP / 04.03.13
Technical Documentation BNWAS 3000
Tel.: +49 (0)4105 / 65 60 – 0 * DECKMA GmbH * Fax: +49 (0)4105 / 65 60 – 25 E-Mail: [email protected] * Internet: www.deckma-gmbh.de
1.6 Installation instructions Version 1.0 10.06.2013 Page 8 of 22
12345AUTO MODE ON/OFF;
JPI1
24V outLED out
gn
gn
2
1
PZ1Signal
gn
gn
24V out
RS485-BRS485-A
12345
REPEATER UNIT
JR1
WATCH ALARM MAIN UNIT
SIGNAL out
3x max
ADR 0
PE
JQ40
JM1
RS485-A
JQ11234
MU
ADR 1
BOOSTER UNIT
RESET out
24V in
GND
LED in
AS WAP
GND
RS485-B
optional
AUTO in
GND24 V in
1234
RSU
PE
ADR 1
RS485-A
ADR 0
RS485-B
AS WAP
PE
24 V inGND
ADR 1
RS485-A
ADR 0
RS485-B
AS WAP
PE
24 V inGND
1234
RESET UNIT
REPEATER UNIT 4
GND
12345678
WATCH ALARM MAIN UNIT
RS485-A
ADR 0
PE
AS WAPADR 1
24 V inGNDRS485-B
ext. Signal generator
24 V out
24V out
REPEATER UNIT 3
12345678
WATCH ALARM MAIN UNIT
JQ1
40x max1234
MURESET UNIT
JR2
LED in
LED out
REPEATER UNIT 2
RESET out
12345678
WATCH ALARM MAIN UNIT
REPEATER UNIT 1
GND
12345678
WATCH ALARM MAIN UNIT
24V in 1234
MU
RESET outLED in
GND
GND
12
JQ1
RESET UNIT
JQ1
24V in
24V ext.
RESET in
GND
RESET in
JE1
GND
ge
ws
br
br
ge
ws
ws
br
ge
24V
ws
br
ge
GND
ws
br
ge
SABOT in
GND12V outRESET in
1234
RESET SENSOR
Sabotage Reset Sensorik1Reset Reset Sensorik1
24 V DCPower supply
24 V DCPower supply
24 V in
PEGND
123
optional
power supply
gn
SELECTOR UNIT
optional
24 V out
RS485-ARS485-B
PE
GND
JR12 12345
RPU
br
ge
ws
RS485-BGND24 V out
RS485-AJR13 PE12345
RPU
ws
br
ws
br
ge
ge
RS485-ARS485-BGND24 V out
JR14 PE12345
RPU
ge
ws
br
RS485-A
24 V in
RS485-B
PE
GND
12345 WATCH ALARM
gn
MAIN UNIT
gn
gn
max. 4 ciruits
each with maximum 4
Repeater Units
JR1
JM1
RS485-A
GND
PE
RS485-B
24 V out
12345
RPU
JR11
Technical Documentation BNWAS 3000
Tel.: +49 (0)4105 / 65 60 – 0 * DECKMA GmbH * Fax: +49 (0)4105 / 65 60 – 25 E-Mail: [email protected] * Internet: www.deckma-gmbh.de
1.6 Installation instructions Version 1.0 10.06.2013 Page 9 of 22
4. Setting the address (REPEATER UNIT)
The REPEATER UNIT functions as a slave within a bus system from where it receives all system relevant data. Since up to four REPEATER UNITS can be connected to the BNWAS, each UNIT requires its own address on the bus. The address can be set by connecting Pins 6 and/or 7 of connector JR1 to ground.
Pin 6 Pin 7 Address
- - 1 Gnd - 2 - Gnd 3 Gnd Gnd 4
If the system is only configured for one REPEATER UNIT, only address 1 must be used. If the system has been configured for two UNITS, address 2 must be added for three UNITS, 3 and for the maximum number (four), 4. If the address no longer corresponds to the system configuration, an error is generated.
5. Accumulator charging
The accumulator is charged via current control. The current can be adjusted with a resistor connected between PINS 3 and 4 on the 24 V accumulator connector (JB1).
Resistor Current
0 - 500 Ω 200 mA 0.800 – 1.200 KΩ 150 mA 1.500 - 3 KΩ 100 mA No resistor – open 50 mA
6. Pin assignments
6.1. WATCH ALARM MAIN UNIT
Pin assignments Power supply 24 V DC 3-pin Weidmüller RM 5.08 JM1
1 24 V in Power supply 24 V DC in 2 GND GND 3 PE Shield
Technical Documentation BNWAS 3000
Tel.: +49 (0)4105 / 65 60 – 0 * DECKMA GmbH * Fax: +49 (0)4105 / 65 60 – 25 E-Mail: [email protected] * Internet: www.deckma-gmbh.de
1.6 Installation instructions Version 1.0 10.06.2013 Page 10 of 22
Pin assignments Power supply 100-240 V AC 3-pin Phoenix RM 5.08 JM2
1 N in 100...240 V AC 2 L in Neutral 3 PE Shield
Pin assignments Accumulator 24 V 5-pin Weidmüller RM 5.08 JB1
1 BP 24 V 2 BM GND 3 SC A Charging current selection 4 SC B Charging current selection 5 PE Shield
Charging current selection
Resistor Charging current
Suitable for accumulators
510R max. 200 mA > 2 A/h 1k max. 150 mA > 1.5 A/h 2k max. 100 mA > 1 A/h None max. 50 mA > 500 mA/h
Pin assignments RESET UNIT 4-pin Weidmüller RM 5.08 JQ1
1 24 V out Power supply 24 V out 2 LED out LED brightness/on/off 3 RESET in Reset 4 GND GND
Technical Documentation BNWAS 3000
Tel.: +49 (0)4105 / 65 60 – 0 * DECKMA GmbH * Fax: +49 (0)4105 / 65 60 – 25 E-Mail: [email protected] * Internet: www.deckma-gmbh.de
1.6 Installation instructions Version 1.0 10.06.2013 Page 11 of 22
Pin assignments REPEATER UNIT 5-pin Weidmüller RM 3.5 JR1 JR2
1 PE Shield 2 RS485-A RS485-A connection to REPEATER UNIT 3 RS485-B RS485-B connection to REPEATER UNIT 4 GND GND 5 24 V out Power supply 24 V out
Pin assignments AUTO MODE ON/OFF; 5-pin Phoenix RM 5.08 JPI1
External signal generator
1 24 V out Power supply 24 V for signal generator 2 SIGNAL out External signal generator 3 NC Not connection 4 AUTO in AUTO MODE ON/OFF 5 GND GND
Pin assignments SERIAL OUT 1 4-pin Weidmüller RM 3.5 JV1
1 RS485-A RS485-A event and alarm out 2 RS485-B RS485-B event and alarm out 3 GND GND 4 PE Shield
Technical Documentation BNWAS 3000
Tel.: +49 (0)4105 / 65 60 – 0 * DECKMA GmbH * Fax: +49 (0)4105 / 65 60 – 25 E-Mail: [email protected] * Internet: www.deckma-gmbh.de
1.6 Installation instructions Version 1.0 10.06.2013 Page 12 of 22
Pin assignments SERIAL OUT 2 9-pin Sub-D female connector JV2
1 2 TXD RS232 TxD service out 3 RXD RS232 RxD service out 4 5 GND GND 6 7 8 9
Pin assignments SERIAL IN 1 6-pin Weidmüller RM 3.5 JG1
1 PE Shield 2 RXD RS232 RxD serial reset/time and date in 3 TXD RS232 TxD serial reset/time and date in 4 RS485-A RS485-A serial reset/time and date in 5 RS485-B RS485-B serial reset/time and date in 6 GND GND
Pin assignments SERIAL IN 2 6-pin Weidmüller RM 3.5 JA1
1 PE Shield 2 RXD RS232 RxD serial reset/time and date in 3 TXD RS232 TxD serial reset/time and date in 4 RS485-A RS485-A serial reset/time and date in 5 RS485-B RS485-B serial reset/time and date in 6 GND GND
Technical Documentation BNWAS 3000
Tel.: +49 (0)4105 / 65 60 – 0 * DECKMA GmbH * Fax: +49 (0)4105 / 65 60 – 25 E-Mail: [email protected] * Internet: www.deckma-gmbh.de
1.6 Installation instructions Version 1.0 10.06.2013 Page 13 of 22
Pin assignments RESET SENSOR 4-pin Phoenix RM 5.08 JE1
1 SABOT in Sabotage 2 RESET in Reset sensor 3 12V out Power supply reset sensor 12 V (max. 100 mA) 4 GND GND
Pin assignments Relay output 9-pin Weidmüller RM 3.5 JK1
1 K1 NO 2. Alarm relay Normally Open 2 K1 CM 2. Alarm relay Com 3 K1 NC 2. Alarm relay Normally Closed 4 K2 NO 3. Alarm relay Normally Open 5 K2 CM 3. Alarm relay Com 6 K2 NC 3. Alarm relay Normally Closed 7 K3 NO Fault relay Normally Open 8 K3 CM Fault relay Com 9 K4 NC Fault relay Normally Closed
Technical Documentation BNWAS 3000
Tel.: +49 (0)4105 / 65 60 – 0 * DECKMA GmbH * Fax: +49 (0)4105 / 65 60 – 25 E-Mail: [email protected] * Internet: www.deckma-gmbh.de
1.6 Installation instructions Version 1.0 10.06.2013 Page 14 of 22
6.2. REPEATER UNIT
Pin assignments WATCH ALARM MAIN UNIT 5-pin Weidmüller RM 3.5 JR1
1 PE Shield 2 RS485-A RS485-A connection to WATCH ALARM MAIN UNIT 3 RS485-B RS485-B connection to WATCH ALARM MAIN UNIT 4 GND GND 5 24 V in Power supply 24 V in 6 ADR 0 Address 0 7 ADR 1 Address 1 8 N.C. N.C.
Technical Documentation BNWAS 3000
Tel.: +49 (0)4105 / 65 60 – 0 * DECKMA GmbH * Fax: +49 (0)4105 / 65 60 – 25 E-Mail: [email protected] * Internet: www.deckma-gmbh.de
1.6 Installation instructions Version 1.0 10.06.2013 Page 15 of 22
6.3. SELECTOR UNIT
Pin assignments Power supply 24 V DC 3-pin Weidmüller RM 5.08 JM1
1 24 V in Power supply 24 V (optional) 2 GND GND 3 PE Shield
Pin assignments WATCH ALARM MAIN UNIT 5-pin Weidmüller RM 3.5 JR1
1 PE Shield 2 RS485-A in RS485-A connection to REPEATER UNIT in 3 RS485-B in RS485-B connection to REPEATER UNIT in 4 GND GND 5 24 V in Power supply 24 V in
Pin assignments REPEATER UNIT 5-pin Weidmüller RM 3.5 JR11...JR14
1 PE Shield 2 RS485-A out RS485-A connection to REPEATER UNIT out 3 RS485-B out RS485-B connection to REPEATER UNIT out 4 GND GND 5 24 V out Power supply 24 V out
Technical Documentation BNWAS 3000
Tel.: +49 (0)4105 / 65 60 – 0 * DECKMA GmbH * Fax: +49 (0)4105 / 65 60 – 25 E-Mail: [email protected] * Internet: www.deckma-gmbh.de
1.6 Installation instructions Version 1.0 10.06.2013 Page 16 of 22
6.4. RESET UNIT
Pin assignments Watch ALARM MAIN UNIT 4-pin Weidmüller RM 3.5 JQ1
1 24 V in Power supply 24 V 2 LED in LED brightness/on/off 3 RESET out Reset 4 GND GND
Technical Documentation BNWAS 3000
Tel.: +49 (0)4105 / 65 60 – 0 * DECKMA GmbH * Fax: +49 (0)4105 / 65 60 – 25 E-Mail: [email protected] * Internet: www.deckma-gmbh.de
1.6 Installation instructions Version 1.0 10.06.2013 Page 17 of 22
6.5. BOOSTER UNIT
Pin assignments Power supply 24 V DC 2-pin Weidmüller RM 5.08 JM1
1 24 V ext. Power supply 24 V external 2 GND GND
Pin assignments WATCH ALARM MAIN UNIT 4-pin Weidmüller RM 3.5 JQ1
1 24 V int. Power supply 24 V internal 2 LED in LED brightness/on/off 3 RESET out Reset 4 GND GND
Pin assignments RESET UNIT 4-pin Weidmüller RM 5.08 JQ40
1 24 V out Power supply 24 V out 2 LED out LED brightness/on/off 3 RESET in Reset 4 GND GND
Technical Documentation BNWAS 3000
Tel.: +49 (0)4105 / 65 60 – 0 * DECKMA GmbH * Fax: +49 (0)4105 / 65 60 – 25 E-Mail: [email protected] * Internet: www.deckma-gmbh.de
1.6 Installation instructions Version 1.0 10.06.2013 Page 18 of 22
7. Current
The WATCH ALARM MAIN UNIT supplies the BNWAS (entire system with all associated UNITS) with power. For this reason, the BNWAS must be configured so that the maximum current of the WATCH ALARM MAIN UNIT is not exceeded.
Note: Several UNITS can be connected to their own power source and supply other UNITS with power. An EXCEL table for precise calculation of the system configuration is available (Consumption BNWAS xxxxx.xls).
8. Accumulator
The accumulator must be dimensioned to supply the BNWAS with power for at least 6 hours.
9. Installation
All WATCH ALARM MAIN UNITS, REPEATER UNIT and SELECTOR UNIT must be installed in a mounting panel (dimensions for cutouts: width = 72 mm, height = 144 mm).
The BOOSTER UNIT must be mounted on a top-hat rail in a panel or control cabinet.
The RESET UNIT (open frame) must be panel or wall mounted and protected against manipulation with special screws.
The RESET UNIT (watertight) must be panel or wall mounted and protected against manipulation with special screws.
It should be noted that connectors, cables and housing openings are not accessible and the system is tamper-proof.
All components except for the RESET UNIT (watertight) must be installed in closed areas and protected from moisture.
10. Audible signal generator
The tone sequence (characteristic beeping) can be configured via the Service menu. The default setting is a long tone and long interval.
The volume should be between 75 dB and 85 dB. If the internal signal generator is insufficient, an external audible signal generator must be connected to JE1.
The signal generators for the second and third alarm must be dimensioned and installed according to the applicable standards.
Technical Documentation BNWAS 3000
Tel.: +49 (0)4105 / 65 60 – 0 * DECKMA GmbH * Fax: +49 (0)4105 / 65 60 – 25 E-Mail: [email protected] * Internet: www.deckma-gmbh.de
1.6 Installation instructions Version 1.0 10.06.2013 Page 19 of 22
11. Reset sensor
The reset sensor can be supplied from a 12 V power supply. The current must be less than 100 mA and must not exceed the total current (see Current).
A reset may only be performed by persons on the bridge.
12. Location
The RESET UNITS or WATCH ALARM MAIN UNIT must be clearly visible and easy to reach from the conning position, workstation for navigation, manoeuvring position, workstation for monitoring and bridge wing.
The RESET UNIT and WATCH ALARM MAIN UNIT must be installed to allow easy access.
Flashing mushroom buttons (WATCH ALARM MAIN UNIT, RESET UNIT) must be clearly visible to the OOW from any point on the bridge.
The alarm of the WATCH ALARM MAIN UNIT (1st alarm) must be clearly audible to the OOW from any point on the bridge. If external areas are to be included, the external signal generator output must be used.
Technical Documentation BNWAS 3000
Tel.: +49 (0)4105 / 65 60 – 0 * DECKMA GmbH * Fax: +49 (0)4105 / 65 60 – 25 E-Mail: [email protected] * Internet: www.deckma-gmbh.de
1.6 Installation instructions Version 1.0 10.06.2013 Page 20 of 22
13. Compass safe distance
Technical Documentation BNWAS 3000
Tel.: +49 (0)4105 / 65 60 – 0 * DECKMA GmbH * Fax: +49 (0)4105 / 65 60 – 25 E-Mail: [email protected] * Internet: www.deckma-gmbh.de
1.6 Installation instructions Version 1.0 10.06.2013 Page 21 of 22
Technical Documentation BNWAS 3000
Tel.: +49 (0)4105 / 65 60 – 0 * DECKMA GmbH * Fax: +49 (0)4105 / 65 60 – 25 E-Mail: [email protected] * Internet: www.deckma-gmbh.de
1.6 Installation instructions Version 1.0 10.06.2013 Page 22 of 22
14. Commissioning
The BNWAS must be configured as described in the operating instructions (accumulator charging current, REPEATER UNIT address, configuration menu) followed by a functional test. It must be ensured that no error messages are generated and all functions work correctly as described. Any faults must be cleared.
All standards and specifications relevant for installation must be observed!
Following commissioning and acceptance, the configuration must be documented as a basic setting in the Service menu on the connected computer. For this purpose, a "C" for setting the UTC (GMT) time must be sent first, followed by an "s" for the Status/ Configuration menu, and after at least five minutes, an "e" for error messages and finally an "m" for the module list. The stored data must be handed to the customer in the form of a log sheet with date and signature together with the delivery documents. The configuration data stored on the service computer is archived with the customer order.