hdpe brochure 5

6
CODlplete Engineering - Our Speciality For more Information Contact OmanCOoLLC P.O.Box 417, Central Post Office, Postal Code 111, Sultanate of Oman Telephone: +96824446600 (6 Lines) - Fax: 24446611 Telex: 5304 AMIANTIT ON - email: [email protected] - Website : www.amiantitoman.com

Upload: muhammad-ahmed

Post on 20-Apr-2015

54 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: HDPE Brochure 5

CODlplete Engineering - Our Speciality

For more InformationContact

OmanCOoLLCP.O.Box 417, Central Post Office, Postal Code 111, Sultanate of Oman

Telephone: +96824446600 (6 Lines) - Fax: 24446611Telex: 5304 AMIANTIT ON - email: [email protected] - Website : www.amiantitoman.com

Page 2: HDPE Brochure 5

"WEHOLITE"@IDGH DENSITY POLYETHYLENE

MANHOLES

hKWHPI Pc

0600 DUCTILE IRONccfvER &. FRAME (BY

NHOLERS) PRECAST RCC SLAB

(BV OTHERS)

HDPE WEHOLITE(SPIRO )SHELL

5 mm.THICK.COMPRESSIBLE

"FILLER MATERI.AL,-._---.---_._ ..~

FINISHED GROUND LEVEL---.- -- '-"-'~-'~'-'I

I.D.

WELDED JOINT

01350 D.D.

SPECIALSj

STEP LADDER(HOPE LUGES)

~1200

XL

r .

J

CORBUNG(BYO~~RS)_

t 150I

TYPE-1

MANUFACTURED UNDER LICENCE FROM PEA GRAVEL

KWH PIPE LTD OF FINLAND

Oman Co. LLC

P.O.Box 417, Central Post Office, Postal Code 111, Sultanate of Oman

Telephone: +96824446600 (6 Lines) - Fax: 24446611Telex: 5304 AMIANTIT ON - email: [email protected] - Website : www.amiantitoman.com

Page 3: HDPE Brochure 5

IIWEHOLITF'@

HIGH DENSITY 'OLYETHYLENE

MANHOLES & DECIAU

·ENGINEEREDFOR WIDE RANGE OF SERVICES,FROM WASTEWATERAND STORMWATERDRAINAGE TOLANDFILLGAS & LANDFILLLEACHATE.

DESCRIPTION

HDPEManholes are available in internal diameters ranging from 800mm up to 3000mm. The cylin­drical carcass is fabricated from a TWINWALL STRUCTUREDHDPE PROFILEpipe (WEHOLlTE)®and isprovided with an eccentric or concentric reducing cone. The manhole depths to invert can rangefrom 1 Meter to 15 Meter and above. The manhole is provided with inlets and outlet pipe and alsowith ladder (if required) and benching.

CONSTRUCTION

The top cone is from a homogenous moulding to match thediameter of the riser. The material is High Density Polyethylene of agrade which facilitates extrusion welding to the main shaft.The base plate is constructed fr9m High Density polyethylene platestiffened to take the weight of maintenance staff.The benching flow path is constructed from mitred pipes cut to suitthe diameters of inlets and outlets. Benching is made to order andpolyethylene ladders are added on customers' request.The flow pipes are stiffened to take the weight of maintenance staff..Ladders are fabricatE?d from 250 mm half pipe.Access is via a top cone set concentrically or eccentrically toensure that maintenance staff have easy and safe reach to the topof the ladder. All manholes are water tested prior to release from the factory.

INSTALLATION

Inler/Outlet

The specialty in using, WEHOLlTEHDPEMANHOLESas described above, is the ease of installation. Itcan be totally prefabricated at our works or at site, based on invert levels and orientation providedby the customer. The Manholes are leak-tested and certified before delivery to site. All it needs atsite is a fairly stable foundation and effective backfilling and compaction.

HANDLING

Use lifting lugs provided on the manhole or use nylon slings with a spreader bar to hoist the manhole.Do not drop the manhole.

SITE PREPARATION

The Excavation at the MANHOLE location should be wide enough to accommodate the manholewith stub outs. Adequate working space should be provided around the Manhole.

FINISHING

The top slab is placed above the HDPEmanhole, and a conventional Manhole cover is then fixedon the top slab. Thiscompletes the Manhole

Page 4: HDPE Brochure 5

'WEHOLlTE" HOPE MANHOLES & specials arepreferred in the Gulf region instead of conventionalManholes because of the following salient features;

11 NON CORROSIVE PROPERTIESSafeMaintenance freeDoes not need internal and external

Protective lining/coating

STRUCTURED PROFILE WALL CONSTRUCTIONResists infiltration and ex-filtrationEasier faster and safer installation

11 LIGHT WEIGHT

Easier handlingCost savings on installation time

11 ENGINEERED CUSTOM BUILTPRODUCTS

Rugged, dependableDimensionally stablePrecision fabricationTested before installation

100% leak proof

Page 5: HDPE Brochure 5

STANDARD MANHOLE DIMENSIONS

RISER ID RISER 00THROUGH PIPE ID

mm

mmmm

1200

1354300 to 700

1500

1685300 to 800

1800

2022300 to 1200

2000

2247300 to 1400

2400

2672300 to 1500

3000

3298300 to 1800

0600 DUCTtl..l: IROf\l MANHOUCOYER • 'RAME (BY OTHERS)

PReCAST RCe 5LA8CBVOTHERS)

Note

1 .

2.

Through pipes of smaller diameter can beprovided for all the above Riser pipes onrequest.

Risersof other intermediate 10sare also

available. Please contact .t}miantit Omanfor further information

COf\BUNG(BY OTHERS)

\111350 O.D.

TYPE·'

FINISHED GROUND LEVEL,-------~:..

15 mm.THlac,COMPRESSIBLEFlLlI:R MATlRlAl.

HDPE Wt:HOlJTf

;. (SPIRO)~

HOPE BeNCHINGr----/'/

RISER

HDPE WEHOl.IT£

HOPE i\!~RIC CONE

/'

TYPE-3

PRIECAST RCC SlA.C.V OTHOS}

e600 DUCTILE IRON MANHOLE r FINISHED ~ROUN~ LfVE_r=0VER. fRAME (aVOTHERS) f--'-- -.---O.BUNG

(~!_.OTHEU) __ "

HOft! BENCHING

HOPE WI!HOlJ1'tRISER

HOP£ WEHOUTfRISER

/

f'lNISHIED GROUND LEVel..MOO 0UCT11.11ttOH MAHHOU!

coveR. fRAME (IV OTltERS)

01650 D.D.

01125 D.D.

01000 !.D.

STEP LAOOER

(HDPlfWGU)

.so

zo~zEz!o••~A\

COftBUNG(nOTHEU)

Page 6: HDPE Brochure 5

CALCULATIONS FOR CHECI( FOR FLOATATION OF

HD'E MANHOLES I CHAMIEV

In areas where Ground Water Level ishigher than the levels of Crowns of pipes connected to an HDPEManhole / Chamber, the safe1ythereof against floatation (Le. Buoyancy) should be checked andwhere necessary anti-floatation anchor should be provided.

A simple anti-floatation anchor consists of a HDPEsheet collar 20 -25 mm thick x OD = (OD ofManhole + 500 mm) extrusion welded on the external surface of ~anhole. Thisresultsin additionalsoil weight acting downward and thus, increasing the Downward Thrust.

However,where substantial increase in Downward Thrustis required, it is necessary to provide precastI Cast-in-sltu RCC anti-floatation anchors, as detailed in the sketches. The precast RCC anchor is inthe form of a 0.3 m thick slab with mesh reinforcement. of sizes 1.2 x 1.5 m, 1.2 x 1.8 m and 1.2 x2.4 m respectively for Manholes dia 1200 mm, 1500 mm and 1800 mm over the pipe stub-outs hav­ing a backflll cushion of 150 mm to 200 mm, as shown in the sketch.

The cast-in-situ RCC anchor is as seen in the photograph below.

•.wn n.crr.T1C\N lI'DI!I:~

·Aao •••._.~~~:"

Anti-Flotation Anchor

UFTlNG HOOK DETAIL