i0522-88 condair gs brochure aw 08-14.qxp layout 1 · depth mm 545 708 1104 1104 1500 1500...

8
CONDAIR GS Gas-fired steam humidifier Economic, high capacity humidification Humidification and Evaporative Cooling

Upload: others

Post on 03-Oct-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: i0522-88 Condair GS Brochure AW 08-14.qxp Layout 1 · Depth mm 545 708 1104 1104 1500 1500 Conformities CE, VDE, GOST, DVGW Condair GC-OC (outdoor unit) i0522-88 Condair GS Brochure

CONDAIR GSGas-fired steam humidifierEconomic, high capacity humidification

Humidification and Evaporative Cooling

i0522-88 Condair GS Brochure AW 08-14.qxp_Layout 1 07/10/2014 11:30 Page 1

Page 2: i0522-88 Condair GS Brochure AW 08-14.qxp Layout 1 · Depth mm 545 708 1104 1104 1500 1500 Conformities CE, VDE, GOST, DVGW Condair GC-OC (outdoor unit) i0522-88 Condair GS Brochure

CONDAIR GSGas-fired steam humidifier

InsulationFully insulated water tank for energyefficient operation.

Wide doorProvides easy access to the water tankfor maintenance.

Heat exchangerThe stainless steel heat exchanger haslarge flat surfaces that shed scaleduring operation, reducingmaintenance and improving thermalefficiency.

Stainless steel water tankQuality construction provides a longand reliable operational lifetime.

i0522-88 Condair GS Brochure AW 08-14.qxp_Layout 1 07/10/2014 11:30 Page 3

Page 3: i0522-88 Condair GS Brochure AW 08-14.qxp Layout 1 · Depth mm 545 708 1104 1104 1500 1500 Conformities CE, VDE, GOST, DVGW Condair GC-OC (outdoor unit) i0522-88 Condair GS Brochure

Control panelA keypad, digital backlit display and LEDindicators make operating thehumidifier simple. The display providesinformation on operational status, faultand maintenance requirements,trouble shooting guidelines and graphsillustrating historic performance anddemand.

360° gas burnerGas combustion occurs uniformlyaround the entire surface of the burner.This maximises thermal transfer to theheat exchanger resulting in thermalefficiency of over 90%.

DrainWater temperature is tempered prior todraining to avoid stress on pipework.

The Condair GS gas-fired steamhumidifier offers high capacity steamgeneration with the economy of usinggas rather than electricity. Savings in

energy costs can result in rapid payback when replacing electric steamhumidifiers.

The Condair GS has been designed toneed minimal maintenance and, when

servicing is required, it is simple and straight forward.

Quality construction, state-of-the-artsafety features, a user-friendly designand a variety of flexible options makethe Condair GS the number one choicefor gas-fired humidification.

i0522-88 Condair GS Brochure AW 08-14.qxp_Layout 1 07/10/2014 11:30 Page 4

Page 4: i0522-88 Condair GS Brochure AW 08-14.qxp Layout 1 · Depth mm 545 708 1104 1104 1500 1500 Conformities CE, VDE, GOST, DVGW Condair GC-OC (outdoor unit) i0522-88 Condair GS Brochure

Fast payback when replacing electric steam humidifiers

If you are using electric steamhumidifiers, retrofitting gas-firedhumidification can pay for itself within1-2 years.

The economy of gas

GasElectricity

Annual humidification energy cost

Humidification output (kg/h)

40

£0k £5k £10k £15k £20k £25k £30k £35k £40k

120

200

240

80

160

Based on full humidifier output for 2,400 hrs per year, gas at3p/kW and electricity at 9p/kW.

i0522-88 Condair GS Brochure AW 08-14.qxp_Layout 1 07/10/2014 11:30 Page 5

Page 5: i0522-88 Condair GS Brochure AW 08-14.qxp Layout 1 · Depth mm 545 708 1104 1104 1500 1500 Conformities CE, VDE, GOST, DVGW Condair GC-OC (outdoor unit) i0522-88 Condair GS Brochure

Advanced features make the Condair GS the most efficient unit of its type on the market

360° full circle burnerThe cylindrical burner in the Condair GShas flame uniformly around its entiresurface. This maximises the thermaltransfer to the heat exchangerresulting in a thermal efficiency of over90%.

The humidifier therefore reacts veryquickly to a requirement forhumidification whilst minimising gasconsumption and emissions. Steamoutput can also be consistentlycontrolled from outputs as low as10kg/hr.

Low maintenanceThe stainless steel heat exchanger haslarge flat surfaces that dislodge scaleduring operation. This scale falls to thebottom of the water tank where it iseither removed by the heavy-dutypumped drain or is emptied duringservicing. The large flat surfaces of the

heat exchanger make it easy to removewhat little scale is left behind. Also, asthe heat exchanger remains mostlyscale-free, the efficiency of heattransfer to the water is maximised.

Scale managementTo reduce scale build-up in the boilingchamber, a low volume of fresh water iscontinually added and high mineralcontent water removed. This not onlydecreases scale build-up but improveshumidity control when compared toother gas-fired humidifiers, whichoccasionally stop steam productionand run a complete tank drain tocombat scale.

Before being sent to drain, waste wateris cooled to minimise stress onpipework.

Industry leading technology

i0522-88 Condair GS Brochure AW 08-14.qxp_Layout 1 07/10/2014 11:30 Page 6

Page 6: i0522-88 Condair GS Brochure AW 08-14.qxp Layout 1 · Depth mm 545 708 1104 1104 1500 1500 Conformities CE, VDE, GOST, DVGW Condair GC-OC (outdoor unit) i0522-88 Condair GS Brochure

Modern building management based on integrated technology. By using communication with the humidification system is simple, quick and clear.

BMS connectivityThe humidifier has an option to beoperated from a BMS and acceptsModbus Standard, BACnet or LonWorksprotocols.

On-board controllerThe Condair GS incorporates a state-of-the-art controller with a backlit LCDdisplay. It has a continuous self-diagnostic feature with self-correctionand fail-safe operation. An on-screentrouble shooting feature walks the userthrough corrective processes that canavoid the expense of an engineer call-out.

Other features include on-screenindication of service and fault historyas well as humidity demand trends.

Up to ten Condair GS humidifiers canbe chained together providing a hugepotential output of up to 2,400kg/hr.

In control

for connection to a BMS

i0522-88 Condair GS Brochure AW 08-14.qxp_Layout 1 07/10/2014 11:30 Page 7

Page 7: i0522-88 Condair GS Brochure AW 08-14.qxp Layout 1 · Depth mm 545 708 1104 1104 1500 1500 Conformities CE, VDE, GOST, DVGW Condair GC-OC (outdoor unit) i0522-88 Condair GS Brochure

With three different models, the Condair GS rangeprovides comprehensive design alternatives

The Condair GS is available in six sizes from 40-240kg/hr and in three different models.

RO water filterThe PureFlo RO water filter removes95% of minerals from supply water toreduce scale build-up and maintenance

Condair OptiSorpRapid evaporation steam distributionmanifold for short absorption distancesinside an AHU

StandFor use with the indoor GS and GS RSmodels

Comprehensive range

Condair GSRoom air dependent model uses air forcombustion from the room

Condair GS RSRoom air independent model can drawair for combustion from an externalsource

Condair GS OCOutdoor unit with an all-weatherenclosure and anti-freeze protection

i0522-88 Condair GS Brochure AW 08-14.qxp_Layout 1 07/10/2014 11:30 Page 8

Page 8: i0522-88 Condair GS Brochure AW 08-14.qxp Layout 1 · Depth mm 545 708 1104 1104 1500 1500 Conformities CE, VDE, GOST, DVGW Condair GC-OC (outdoor unit) i0522-88 Condair GS Brochure

Condair plc - the new name for JS HumidifiersArtex Avenue, Rustington, Littlehampton, West Sussex, BN16 3LN, UKTel: +44 (0)1903 850200 - [email protected] - www.condair.co.uk

10/2014

Standard system

Stainless steel heat exchanger360° full circle burnerInternal PI humidity controllerControl panel with LCD displaySelf diagnostic systemStand for internal room units

Options

for BMS connectionOptiSorp rapid steam distribution manifoldPressure compensation to 10,000PaPureFlo reverse osmosis water filterHumidity sensors and humidistats

Technical data

Accesssories

1 Steam distribution2 Steam hose3 Condensate hose 4 Flue

1

23

4

Max. steam output kg/h 40 80 120 160 200 240

Gas consumption kW 36.5 73.0 109.5 146.0 182.5 219.0

Gas types Natural gas, G13, G20, G25, G30, G37, G50 or propane gas G31

Admissible duct air pressure -800…+1700Pa

Water quality Untreated drinking water or demineralised

Width / height mm 1140/810

Depth mm 530 690 1090 1090 1490 1490

Condair GS (room air dependent), Condair GS RS (room air independent)

Width / height mm 1262/1380

Depth mm 545 708 1104 1104 1500 1500

Conformities CE, VDE, GOST, DVGW

Condair GC-OC (outdoor unit)

i0522-88 Condair GS Brochure AW 08-14.qxp_Layout 1 07/10/2014 11:30 Page 9