  • ICORR ABERDEEN BRANCH

    WELCOMES

    CHRIS BURKE, BENG (HONS), MIET

    Aberdeen Branch Key Sponsor

    1

    Corrosion Awareness Day 2018

  • Aberdeen Branch Key Sponsor

    2Corrosion Awareness Day 2018

    Emerson Corrosion Monitoring Solutions

    Non- intrusiveIntrusive

    High sensitivity, quick response Actual metal loss, wall thickness

    Electrochemical

    (LPR, Galvanic)

    Corrosivity

    Electrical

    resistance (ER)

    Corrosivity or

    erosion through

    metal loss

    EVALUATE RISK MEASURE IMPACT

    Ultrasonic

    (UT)

    Wall thickness

    Field Signature

    Method (FSM)

    Wall thickness,

    area coverage

    Acoustic

    Solids detection

  • >20,000 sensors in >180 facilities in >30 countries

    >18 million wall thickness measurements delivered to desk, >170 million operating hours

    Key Sponsor

    3

  • CHRIS BURKEUPSTREAM SALES MANAGER

    Aberdeen Branch Key Sponsor

    4

    Corrosion Awareness Day 2018

    • BEng (Hons) Electronic & Communication Engineering – Robert Gordon University

    • Member of the Institute of Engineering and Technology

    • 20+ years experience in the Oil and Gas Industry

    • 15+ years Asset Integrity Experience:

    - Support Engineer - Roxar

    - Corrosion & Erosion Monitoring Engineer - ConocoPhillips

    - Senior Engineer – Oceaneering

    - Senior Project Engineer – SMS

    - Consultant – Sandman Engineering

    - Sales Manager - Permasense

  • PERMASENSE EQUIPMENT

    DEMONSTRATION

    Aberdeen Branch Key Sponsor

    5Corrosion Awareness Day 2018

    • PERMASENSE TECHNOLOGY

    • DATA ACCURACY AND REPEATABILITY

    • CHALLENGES FACING ULTRASONICS

    • DATA TO DESK: DATAMANGER

    • QUESTIONS

  • 6

    Permasense History

    Corrosion Awareness Day 2018

    High temperature – waveguide / sensor technology prototype

    Proving out of monitoring technology in BP Refineries

    Exclusive agreement with BP finishes

    Reference installations with all major oil companies

    Reference applications across the oil and gas sector

    2013

    2012

    2011

    2006-08

    2005

    Imperial College of Science,

    Technology and Medicine

    2016 Acquisition into Emerson

  • 7

    WT Technology - Unique High Temperature

    Capability

    Corrosion Awareness Day 2018

    • Based on established ultrasound technology

    – Unique waveguide transducer

    – Permanent installation

    • Install anywhere

    – Temperatures up to 600 C (1100°F), e.g. refinery crude unit pipework

    – Temperatures down to -180 C (-292°F), e.g. LNG plants

    – Intrinsically safe (Class1 Div1)

    • Data to Desk

    – WirelessHART

    – 7-9 year battery life

    – Remotely adjustable data acquisition rate

    – Automated temperature and material compensation

    – Unique and patented processing to eliminate internal surface roughness effects and detect onset of corrosion activity

  • 8

    ET Technology – Magnetic Mountis,

    Measure Through Coatings

    Corrosion Awareness Day 2018

  • 9

    EMAT based sensor specifications

    Corrosion Awareness Day 2018

    PERMASENSE QUALITY

    DATA

    INTRINSICALLY SAFE

    SENSORS

    ULTRA-LOW POWER

    CONSUMPTION: up to 9 year

    battery life

    NO NEED TO REMOVE

    EXTERNAL COATINGS

    WirelessHART TECHNOLOGY

    • Very low power

    • Very simple, strong magnetic attachment

    • Easy-fix retention strap

    • 120°C/250°F maximum wall temperature

    • Automated temperature and material compensation

    • Advanced proprietary signal processing

  • 10

    Sensor for Any Location, Operating at

    Any Temperature

    Corrosion Awareness Day 2018

    Temperature range

    Up to 120oC (248oF)Up to 300oC (572oF) Up to 600oC (1100oF)

    Measurement technique

    Ultrasound - EMAT Ultrasound - Waveguide

    Sharing WirelessHART infrastructure - All data viewed in Data Manager, at desk

    ET210

    ET410 WT210

  • 11

    System Overview – Real Time Data to Desk

    Corrosion Awareness Day 2018

    Measurement Communication Analytics

    Up to 100 sensors per

    gateway

    Easily installed, on-line. Typical size system installed in 3-4 days.

  • 12

    Best Quality and Frequency of Thickness

    Measurements

    Corrosion Awareness Day 2018

    • Fast response to corrosion and/or erosion

    – Excellent measurement repeatability affords detection and measurement of ≈ 10 microns of metal wall loss

    – Regular data delivery (e.g. every 12 hours) allows detection of corrosion or erosion events within days

  • 13

    Significant Enhancement Over Traditional

    Manual Inspection

    Corrosion Awareness Day 2018

    • Permasense: measurements every 12 hours within +/- 10 microns variation; catch onset of corrosion events within days

    • Manual UT inspection: years between measurements with +/- 0.5-1.0 mm variation; corrosion rate calculation not possible, corrosion events missed

  • 14

    Turnaround Planning

    Corrosion Awareness Day 2018

  • 15

    Temperature Compensation Simplifies Data

    Interpretation

    Corrosion Awareness Day 2018

  • 16

    Dealing With Internal Surface Roughness or

    Pitting

    Corrosion Awareness Day 2018

    No clear peak

    Permasense is unique in solving this challenge

    Roughness scattering

    affects all ultrasound-based

    thickness measurements

  • 17

    Unique Advanced Signal Processing

    Corrosion Awareness Day 2018

    PS

    I sc

    ale

    To

    tal su

    lph

    ur c

    on

    ten

    t, (wt. %

    )

    Adaptive Cross Correlation, AXC

    • Adaptive Cross Correlation, AXC

    – Correlation where signal matches previous backwall

    signal most closely

    – Roughness scattering effect is overcome

    • Permasense Shape Indicator, PSI

    – Correlation to previous backwall signal introduces

    backwall reflection and morphology change indicator

    – Early warning of the onset of localised corrosion / pitting

    Permasense Shape Indicator, PSI

    Standard processing

    AXC

  • 18

    Arrays of Sensors for Localised

    Corrosion

    Corrosion Awareness Day 2018

    e.g. of

    area

    monitored

    by sensor

    grid

    10% 15%

    20%

    • No. of sensors required decreases as

    % of area monitored exhibiting

    corrosion activity increases

    • Choose area monitored to maximise %

    showing activity

    Examples of localised

    corrosion attack

    Example: 25% of area experiences corrosion attack.

    10 sensors give 95% confidence of detection

    0.80

    0.85

    0.90

    0.95

    1.00

    5 10 15 20 25 30Co

    nfi

    de

    nce

    in d

    ete

    ctio

    n

    No. of sensors

    10% of area Monitored exhibiting

    15%20%

    25%

    25%

    Transfer line – 26 sensor array 15cm/20cm (6”/8”) bend – 14

    sensor array

    Close-proximity locations for high probability

    of detection

  • 19

    Data Manager: Data Visualisation and

    Analytics

    Corrosion Awareness Day 2018

  • 20

    Data Manager: Data Visualisation and

    Analytics

    Corrosion Awareness Day 2018

  • 21

    Data Manager: Data Visualisation and

    Analytics

    Corrosion Awareness Day 2018

  • 22

    Data Manager: Data Visualisation and

    Analytics

    Corrosion Awareness Day 2018