STATEMENT: This test may not be duplicated or used in part without prior written consent from Bay Area Compliance Laboratories Corp. (Shenzhen). The test data was only valid for the test sample(s). This report must not be used by the customer to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the U.S. Federal Government. This report is valid only with a valid digital signature. The digital signature may be available only under the Adobe software above version 7.0. IES LM-79-08 MEASUREMENT AND TEST REPORT For Jaykal LED Solutions, Inc 35765 Black Marlin Drive Lewes, Delaware 19958, USA Test Model: JLS68103-G150-SBCL Report Type: Electrical and Photometric tests including: Luminous Flux, Color, Luminous Intensity Distribution, THD, Off-state Power Test Engineer: Daniel Duan Report Number: RSZ140305510-10 Test Date: 2014-03-12 to 2014-03-22 Report Date: 2014-04-01 Reviewed By: Jeanne Han/Safety Manager Prepared By: Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian Free Trade Zone Shenzhen, Guangdong, China Tel: +86-755-33320018 Fax: +86-755-33320008 Test Facility: Test facility was located at Pu Long Cun 69, Puxinghu Industrial Area, Tangxia Town, Dongguan, Guangdong, P.R.China. Accreditation: The NVLAP Lab Code is 200707-0.

Upload: vudat

Post on 16-Mar-2018

214 views

Category:

Documents


2 download

TRANSCRIPT

Page 1: IES LM-79-08 - jls-china. · PDF fileSTATEMENT: This test may not be duplicated or used in part without prior written consent from Bay Area Compliance Laboratories Corp. ... This report

STATEMENT: This test may not be duplicated or used in part without prior written consent from Bay Area Compliance Laboratories Corp.

(Shenzhen). The test data was only valid for the test sample(s). This report must not be used by the customer to claim product certification,

approval, or endorsement by NVLAP, NIST, or any agency of the U.S. Federal Government.

This report is valid only with a valid digital signature. The digital signature may be available only under the Adobe software above version 7.0.

IES LM-79-08

MEASUREMENT AND TEST REPORT For

Jaykal LED Solutions, Inc 35765 Black Marlin Drive Lewes, Delaware 19958, USA

Test Model: JLS68103-G150-SBCL

Report Type:

Electrical and Photometric tests including: Luminous Flux,

Color, Luminous Intensity Distribution, THD, Off-state

Power

Test Engineer: Daniel Duan

Report Number: RSZ140305510-10

Test Date: 2014-03-12 to 2014-03-22

Report Date: 2014-04-01

Reviewed By: Jeanne Han/Safety Manager

Prepared By:

Bay Area Compliance Laboratories Corp. (Shenzhen)

6/F, the 3rd Phase of WanLi Industrial Building,

ShiHua Road, FuTian Free Trade Zone

Shenzhen, Guangdong, China

Tel: +86-755-33320018

Fax: +86-755-33320008

Test Facility: Test facility was located at Pu Long Cun 69, Puxinghu Industrial

Area, Tangxia Town, Dongguan, Guangdong, P.R.China.

Accreditation: The NVLAP Lab Code is 200707-0.

Page 2: IES LM-79-08 - jls-china. · PDF fileSTATEMENT: This test may not be duplicated or used in part without prior written consent from Bay Area Compliance Laboratories Corp. ... This report

Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian

Free Trade Zone Shenzhen, Guangdong, China

Report No. RSZ140305510-10 Page 2 of 12 The NVLAP Lab Code is 200707-0.

1. Product Description

General Information:

Sample No.: RSZ140305510-S01 Model: JLS68103-G150-SBCL One sample was received on 2014-03-05 and used for testing.

Model Tested: JLS68103-G150-SBCL

Manufacturer: Jaykal LED Solutions, Inc

Brand Name: Jaykal LED Solutions, Inc

Product Designation: Outdoor Pole/Arm-Mounted Area and Roadway Luminaires

Burning Time Before Test: 0 hour(For New Products)

Rated Values:

Rated Voltage/Frequency: 100-277 VAC 50/60Hz

Rated Power: 150W

Nominal CCT: 5500K

Nominal CRI: 75

2. Standards Used

IESNA LM-79-08: Approved Method: Electrical & Photometric Measurement of Solid-state Lighting Products

ANSI C82.77-2002: Harmonic Emission Limits – Related Power Quality Requirements for Lighting

3. Description of Test Equipment

Device Manufacture Model No Serial No Test Range Calibration date

1.5m temperature

integrating sphere SENSING SPR-600 S09008 25~50℃ N/A

Spectral radiation analyzer SENSING SPR3000 90902027 350nm~800nm N/A

Digital power meter YOKOGAWA WT-210 91j926132 15/30/60/150/300/60

0 V 2013-03-25

Precision frequency power

supply ALL Power APW-105N 970613 0V-300V 50-400Hz 2013-03-25

Standard Light Source SENSING N/A LSD090808 N/A 2013-05-13

Temperature/humidity/cloc

k Victor VC230 EE209 0~40℃0~90% 2013-04-01

Programmable Precision

DC Power Supply ITECH IT6154

0061 0417

6471 0010 19 0~60V 2013-03-25

AC POWER SUPPLY EVERFINE VPS1060 PWM 1101006 0-150V, 0-300V 2013-03-25

Digital CC&CV DC Power

Supply EVERFINE WY12010 1009009 30V/5A 2013-03-25

Electrical parameter tester YOKOGAWA WT-210 91KB35700 15/30/60/150/300/60

0 V 2013-03-25

full-field speed

goniophotometer EVERFINE GO-R5000

YG108492N1

0120001 1600mm,3000W/10A N/A

Temperature/humidity/cloc

k Victor VC230 EE091 0~40℃0~90% 2013-04-01

Standard Light Source EVERFINE D908 1012001 N/A 2013-05-28

Page 3: IES LM-79-08 - jls-china. · PDF fileSTATEMENT: This test may not be duplicated or used in part without prior written consent from Bay Area Compliance Laboratories Corp. ... This report

Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian

Free Trade Zone Shenzhen, Guangdong, China

Report No. RSZ140305510-10 Page 3 of 12 The NVLAP Lab Code is 200707-0.

Statement of Traceability: Bay Area Compliance Laboratories Corp. (Shenzhen) attested that all calibration has been

performed using suitable standards traceable to National Primary Standards and International System of Units (SI).

4. Test Method

Product was tested with no seasoning. All stabilization and measurements were made in compliance with IES LM-79-08. The product was operated at rated voltage or at voltage required by manufacturer. The ambient temperature of the sample was maintained at 25°C±1°C during measurement. And relative humidity is less than 65%.

Integrating Sphere System

The system includes AC power source, digital power meter, DC power supply, spectrophotometer, and integrating sphere. The integrating sphere system is calibrated by standard light source before measurement. The system and standard light source has been calibrated regularly and traceable to the National Primary Standards.

4π geometry was used during measurement. The product was operated in its intended orientation in application and was recorded in this report.

The uncertainty of the light output (luminous flux) measurements is U=1.64% (K=2), at the 95% confidence level. The

uncertainty of the correlated color temperature measurements is U=21K (K=2), at the 95% confidence level. The

uncertainty of the CRI is U=1.6 (K=2) , at the 95% confidence level.

Goniophotometer System

The goniophotometer system is calibrated by standard light source before measurement. The standard light source has been calibrated regularly and traceable to the National Primary Standards.

Type C goniophotometer was used for measuring total luminous flux, luminous intensity distribution, and color spatial uniformity. The product was operated in its intended orientation in application and was recorded in this report.

The uncertainty of the luminous intensity is U=2.82% (K=2) , at the 95% confidence level.

Additional Test

The Additional Test item may not be covered by IESNA LM-79-2008. Additional test including power factor, off-state power and THD, was measured by Digital Power Meter after stabilized at 25°C±1°C.Test voltage for THD and power factor test would be equal to rated voltage or, in case of a voltage range, maximum value of that range.

The uncertainty of power meter AC current U=0.19 % of rdg, AC Voltage U=0.15% of rdg, Power U=0.20%) (K=2), at

the 95% confidence level.

Page 4: IES LM-79-08 - jls-china. · PDF fileSTATEMENT: This test may not be duplicated or used in part without prior written consent from Bay Area Compliance Laboratories Corp. ... This report

Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian

Free Trade Zone Shenzhen, Guangdong, China

Report No. RSZ140305510-10 Page 4 of 12 The NVLAP Lab Code is 200707-0.

5. Test Result

[Integrating Sphere System]

Total operating time for integrating sphere test: 1.5 hours

Test orientation: Downward

Electrical Measurement

Voltage (V) Frequency (Hz) Current (A) Power (W) Power Factor

119.95 60.0 1.3316 159.18 0.997

Photometric Measurement

Luminous Flux (lm) Radiant Flux (W) Efficacy (lm/W) CCT (K) Duv

11590.29 31.620 72.812 5732 7.32E-03

Chromaticity Coordinate

x y u v u' v'

0.3270 0.3508 0.1995 0.3211 0.1995 0.4816

Color Rendering Index

Ra

72.0

R1 R2 R3 R4

69 75 82 74

R5 R6 R7 R8

72 69 78 58

R9 R10 R11 R12

-34 43 74 55

R13 R14 R15

70 89 61

Page 5: IES LM-79-08 - jls-china. · PDF fileSTATEMENT: This test may not be duplicated or used in part without prior written consent from Bay Area Compliance Laboratories Corp. ... This report

Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian

Free Trade Zone Shenzhen, Guangdong, China

Report No. RSZ140305510-10 Page 5 of 12 The NVLAP Lab Code is 200707-0.

Relative Spectral Power Distribution

nm mW

nm mW

nm mW

nm mW

nm mW

380 2.733E-02 465 2.408E-01 550 8.283E-01 635 3.820E-01 720 4.109E-02

385 1.607E-02 470 2.006E-01 555 8.310E-01 640 3.443E-01 725 3.583E-02

390 1.294E-02 475 2.025E-01 560 8.386E-01 645 3.074E-01 730 3.089E-02

395 1.049E-02 480 2.282E-01 565 8.358E-01 650 2.722E-01 735 2.772E-02

400 1.284E-02 485 2.823E-01 570 8.273E-01 655 2.422E-01 740 2.401E-02

405 2.229E-02 490 3.539E-01 575 8.163E-01 660 2.138E-01 745 2.147E-02

410 4.919E-02 495 4.273E-01 580 7.944E-01 665 1.882E-01 750 1.883E-02

415 1.147E-01 500 4.966E-01 585 7.695E-01 670 1.633E-01 755 1.703E-02

420 2.476E-01 505 5.569E-01 590 7.473E-01 675 1.445E-01 760 1.570E-02

425 4.762E-01 510 6.141E-01 595 7.147E-01 680 1.261E-01 765 1.413E-02

430 8.105E-01 515 6.584E-01 600 6.746E-01 685 1.098E-01 770 1.270E-02

435 1.226E+00 520 6.971E-01 605 6.415E-01 690 9.494E-02 775 1.148E-02

440 1.525E+00 525 7.236E-01 610 5.996E-01 695 8.275E-02 780 1.075E-02

445 1.260E+00 530 7.539E-01 615 5.564E-01 700 7.109E-02 785 9.605E-03

450 7.658E-01 535 7.753E-01 620 5.110E-01 705 6.254E-02 790 9.018E-03

455 4.872E-01 540 7.964E-01 625 4.663E-01 710 5.420E-02 795 8.757E-03

460 3.452E-01 545 8.132E-01 630 4.240E-01 715 4.707E-02 800 8.434E-03

0.0

0.2

0.4

0.6

0.8

1.0

1.2

380 440 500 560 620 680 740 800

Page 6: IES LM-79-08 - jls-china. · PDF fileSTATEMENT: This test may not be duplicated or used in part without prior written consent from Bay Area Compliance Laboratories Corp. ... This report

Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian

Free Trade Zone Shenzhen, Guangdong, China

Report No. RSZ140305510-10 Page 6 of 12 The NVLAP Lab Code is 200707-0.

CIE 1931 x y Chromaticity Diagram

7-Step & 4-Step Chromaticity Quadrangles

0

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

0.9

0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8

0.30

0.35

0.40

0.45

0.30 0.35 0.40 0.45 0.50

sample

7-STEP 2700K

7-STEP 3000K

7-STEP 3500K

7-STEP 4000K

7-STEP 4500K

7-STEP 5000K

7-STEP 5700K

7-STEP 6500K

4-STEP 2700K

4-STEP 3000K

4-STEP 3500K

4-STEP 4000K

4-STEP 5000K

4-STEP 6500K

Page 7: IES LM-79-08 - jls-china. · PDF fileSTATEMENT: This test may not be duplicated or used in part without prior written consent from Bay Area Compliance Laboratories Corp. ... This report

Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian

Free Trade Zone Shenzhen, Guangdong, China

Report No. RSZ140305510-10 Page 7 of 12 The NVLAP Lab Code is 200707-0.

[Goniophotometer System]

Total operating time for luminous intensity distribution: 1.5 hours

Test orientation: Downward

Electrical Measurement

Input Voltage (V) Frequency (Hz) Input Current (A) Power (W) Power Factor

120.1 60.0 1.319 157.7 0.9955

Photometric Measurement

Luminous Flux (lm) Efficacy (lm/W) CBCP (cd) S/MH (C0/180) S/MH (C90/270)

11973.8 75.91 4607 1.32 1.32

Luminous Intensity Distribution

C0/180 C45/225 C90/270 C135/315 AVG.

Beam Angle (50% Imax): 115.9 109.0 109.9 109.6 111.1

Field Angle (10% Imax): 146.1 144.6 145.6 146.2 145.6

Page 8: IES LM-79-08 - jls-china. · PDF fileSTATEMENT: This test may not be duplicated or used in part without prior written consent from Bay Area Compliance Laboratories Corp. ... This report

Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian

Free Trade Zone Shenzhen, Guangdong, China

Report No. RSZ140305510-10 Page 8 of 12 The NVLAP Lab Code is 200707-0.

Luminous Intensity (cd) Distribution Data

C

0° 22.5° 45° 67.5° 90° 112.5° 135° 157.5° γ

0.0° 4607 4603 4600 4601 4595 4594 4591 4588

5.0° 4581 4602 4603 4605 4603 4609 4609 4601

10.0° 4546 4556 4542 4555 4559 4562 4563 4569

15.0° 4493 4480 4474 4487 4488 4497 4506 4511

20.0° 4394 4380 4377 4377 4388 4399 4415 4427

25.0° 4264 4249 4242 4244 4254 4282 4304 4315

30.0° 4103 4089 4080 4083 4096 4116 4154 4174

35.0° 3911 3892 3879 3882 3894 3928 3979 3997

40.0° 3687 3654 3640 3625 3179 3696 3763 3786

45.0° 3088 3290 3351 2840 2853 2908 3504 3533

50.0° 2786 2751 2714 2560 2576 2644 3017 2933

55.0° 2453 2407 2057 2227 2258 2324 2364 2602

60.0° 1854 2006 1671 1847 1878 1960 1865 2208

65.0° 1425 1347 1242 1376 1408 1508 1464 1537

70.0° 718 616 592 585 634 731 806 804

75.0° 236 172 157 186 222 258 259 277

80.0° 59 51 47 47 53 59 71 69

85.0° 10 10 11 12 13 12 11 12

90.0° 0 0 0 0 0 0 0 0

95.0° 0 0 0 0 0 0 0 0

100.0° 0 0 0 0 0 0 0 0

105.0° 0 0 0 0 0 0 0 0

110.0° 0 0 0 0 0 0 0 0

115.0° 0 0 0 0 0 0 0 0

120.0° 0 0 0 0 0 0 0 0

125.0° 0 0 0 0 0 0 0 0

130.0° 0 0 0 0 0 0 0 0

135.0° 0 0 0 0 0 0 0 0

140.0° 0 0 0 0 0 0 0 0

145.0° 0 0 0 0 0 0 0 0

150.0° 0 0 0 0 0 0 0 0

155.0° 0 0 0 0 0 0 0 0

160.0° 0 0 0 0 0 0 0 0

165.0° 0 0 1 1 1 0 0 0

170.0° 0 0 0 0 0 0 0 0

175.0° 0 0 0 0 0 0 0 0

180.0° 0 0 0 0 0 0 0 0

Page 9: IES LM-79-08 - jls-china. · PDF fileSTATEMENT: This test may not be duplicated or used in part without prior written consent from Bay Area Compliance Laboratories Corp. ... This report

Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian

Free Trade Zone Shenzhen, Guangdong, China

Report No. RSZ140305510-10 Page 9 of 12 The NVLAP Lab Code is 200707-0.

Luminous Intensity (cd) Distribution Data (cont.)

C

180° 202.5° 225° 247.5° 270° 292.5° 315° 337.5° γ

0.0° 4607 4603 4600 4601 4595 4594 4591 4588

5.0° 4601 4568 4543 4540 4534 4531 4528 4536

10.0° 4575 4520 4489 4387 4206 4330 4415 4475

15.0° 4518 4447 4063 3807 3799 3796 4025 4457

20.0° 4436 4350 3744 3725 3714 3705 3708 4345

25.0° 4325 4043 3636 3617 3604 3598 3600 4056

30.0° 4189 3556 3512 3489 3471 3462 3466 3507

35.0° 4017 3388 3362 3331 3313 3309 3306 3304

40.0° 3806 3211 3176 3148 3128 3118 3116 3109

45.0° 3425 2994 2969 2935 2908 2905 2901 2805

50.0° 2938 2496 2725 2689 2649 2654 2652 2382

55.0° 2605 2215 2417 2397 2350 2358 2195 2102

60.0° 2213 1893 1910 2044 1992 2007 1836 1782

65.0° 1554 1341 1531 1315 1266 1276 1455 1245

70.0° 875 890 759 877 825 801 697 675

75.0° 332 327 337 351 285 329 264 245

80.0° 71 66 75 82 64 74 66 56

85.0° 13 14 16 17 15 16 14 13

90.0° 0 0 0 0 0 0 0 0

95.0° 0 0 0 0 0 0 0 0

100.0° 0 0 0 0 0 0 0 0

105.0° 0 0 0 0 0 0 0 0

110.0° 0 0 0 0 0 0 0 0

115.0° 0 0 0 0 0 0 0 0

120.0° 0 0 0 0 0 0 0 0

125.0° 0 0 0 0 0 0 0 0

130.0° 0 0 0 0 0 0 0 0

135.0° 0 0 0 0 0 0 0 0

140.0° 0 0 0 0 0 0 0 0

145.0° 0 0 0 0 0 0 0 0

150.0° 0 0 0 0 0 0 0 0

155.0° 0 0 0 0 0 0 0 0

160.0° 0 0 0 0 0 0 0 0

165.0° 0 0 0 0 0 0 0 0

170.0° 0 0 0 0 0 0 0 0

175.0° 0 0 0 0 0 0 0 0

180.0° 0 0 0 0 0 0 0 0

Page 10: IES LM-79-08 - jls-china. · PDF fileSTATEMENT: This test may not be duplicated or used in part without prior written consent from Bay Area Compliance Laboratories Corp. ... This report

Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian

Free Trade Zone Shenzhen, Guangdong, China

Report No. RSZ140305510-10 Page 10 of 12 The NVLAP Lab Code is 200707-0.

Average Area Illumination Figure

Height (m) Diameter

(cm) Eavg(lx) Emax(lx)

0.5 145.8 5490.0 18443.0

1.0 291.5 1373.0 4611.0

1.5 437.3 610.0 2049.0

2.0 583.1 343.1 1153.0

2.5 728.9 219.6 737.7

3.0 874.6 152.5 512.3

3.5 1020.4 112.0 376.4

4.0 1166.2 85.8 288.2

4.5 1312.0 67.8 227.7

5.0 1457.7 54.9 184.4

Angle: 111.1°. Flux out: 9478.0 lm.

Page 11: IES LM-79-08 - jls-china. · PDF fileSTATEMENT: This test may not be duplicated or used in part without prior written consent from Bay Area Compliance Laboratories Corp. ... This report

Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian

Free Trade Zone Shenzhen, Guangdong, China

Report No. RSZ140305510-10 Page 11 of 12 The NVLAP Lab Code is 200707-0.

Zonal Lumen Density Measurement

Deg Flux (lm) %

Deg Flux (lm) %

0-5 109.6 0.92 0-5 109.6 0.92

5-10 324.7 2.71 0-10 434.4 3.63

10-15 520.0 4.34 0-15 954.4 7.97

15-20 697.7 5.83 0-20 1652.0 13.80

20-25 863.1 7.20 0-25 2515.1 21.00

25-30 997.5 8.34 0-30 3512.6 29.34

30-35 1106.5 9.24 0-35 4619.0 38.58

35-40 1187.0 9.91 0-40 5806.1 48.49

40-45 1202.5 10.04 0-45 7008.6 58.53

45-50 1168.5 9.76 0-50 8177.1 68.29

50-55 1093.3 9.13 0-55 9270.3 77.42

55-60 987.6 8.25 0-60 10257.9 85.67

60-65 807.0 6.74 0-65 11064.9 92.41

65-70 554.9 4.63 0-70 11619.8 97.04

70-75 255.3 2.14 0-75 11875.1 99.18

75-80 77.9 0.65 0-80 11953.0 99.83

80-85 17.4 0.14 0-85 11970.4 99.97

85-90 2.7 0.02 0-90 11973.1 99.99

90-95 0.0 0.00 0-95 11973.1 99.99

95-100 0.0 0.00 0-100 11973.2 99.99

100-105 0.0 0.00 0-105 11973.2 99.99

105-110 0.0 0.01 0-110 11973.3 100.00

110-115 0.0 0.00 0-115 11973.3 100.00

115-120 0.0 0.00 0-120 11973.3 100.00

120-125 0.0 0.00 0-125 11973.4 100.00

125-130 0.0 0.00 0-130 11973.4 100.00

130-135 0.0 0.00 0-135 11973.5 100.00

135-140 0.0 0.00 0-140 11973.5 100.00

140-145 0.0 0.00 0-145 11973.6 100.00

145-150 0.0 0.00 0-150 11973.6 100.00

150-155 0.0 0.00 0-155 11973.7 100.00

155-160 0.0 0.00 0-160 11973.7 100.00

160-165 0.0 0.00 0-165 11973.7 100.00

165-170 0.0 0.00 0-170 11973.8 100.00

170-175 0.0 0.00 0-175 11973.8 100.00

175-180 0.0 0.00 0-180 11973.8 100.00

Page 12: IES LM-79-08 - jls-china. · PDF fileSTATEMENT: This test may not be duplicated or used in part without prior written consent from Bay Area Compliance Laboratories Corp. ... This report

Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian

Free Trade Zone Shenzhen, Guangdong, China

Report No. RSZ140305510-10 Page 12 of 12 The NVLAP Lab Code is 200707-0.

[Additional Test]

Test Item Test Voltage (V) Frequency (Hz) Test Result

Power Factor: 277 60 0.943

Total Harmonic Distortion: 277 60 9.2%

Total Harmonic Distortion: 120 60 4.3%

Off State Power (W): 120 60 0.0

6. Product Photo

***********END OF REPORT***********