STATEMENT: This test may not be duplicated or used in part without prior written consent from Bay Area Compliance Laboratories Corp. (Shenzhen). The test data was only valid for the test sample(s). This report must not be used by the customer to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the U.S. Federal Government. This report is valid only with a valid digital signature. The digital signature may be available only under the Adobe software above version 7.0. IES LM-79-08 MEASUREMENT AND TEST REPORT For Jaykal LED Solutions, Inc 35765 Black Marlin Drive Lewes, Delaware 19958, USA Test Model: JLS68103-G100-SBCL Report Type: Electrical and Photometric tests including: Luminous Flux, Color, Luminous Intensity Distribution, THD, Off-state Power Test Engineer: Daniel Duan Report Number: RSZ140305509-10 Test Date: 2014-03-12 to 2014-03-22 Report Date: 2014-04-01 Reviewed By: Jeanne Han/Safety Manager Prepared By: Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian Free Trade Zone Shenzhen, Guangdong, China Tel: +86-755-33320018 Fax: +86-755-33320008 Test Facility: Test facility was located at Pu Long Cun 69, Puxinghu Industrial Area, Tangxia Town, Dongguan, Guangdong, P.R.China. Accreditation: The NVLAP Lab Code is 200707-0.

Upload: nguyenthuan

Post on 16-Mar-2018

213 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: IES LM-79-08 - JLS- · PDF fileSTATEMENT: This test may not be duplicated or used in part without prior written consent from Bay Area Compliance Laboratories Corp. ... This report

STATEMENT: This test may not be duplicated or used in part without prior written consent from Bay Area Compliance Laboratories Corp.

(Shenzhen). The test data was only valid for the test sample(s). This report must not be used by the customer to claim product certification,

approval, or endorsement by NVLAP, NIST, or any agency of the U.S. Federal Government.

This report is valid only with a valid digital signature. The digital signature may be available only under the Adobe software above version 7.0.

IES LM-79-08

MEASUREMENT AND TEST REPORT For

Jaykal LED Solutions, Inc 35765 Black Marlin Drive Lewes, Delaware 19958, USA

Test Model: JLS68103-G100-SBCL

Report Type:

Electrical and Photometric tests including: Luminous Flux,

Color, Luminous Intensity Distribution, THD, Off-state

Power

Test Engineer: Daniel Duan

Report Number: RSZ140305509-10

Test Date: 2014-03-12 to 2014-03-22

Report Date: 2014-04-01

Reviewed By: Jeanne Han/Safety Manager

Prepared By:

Bay Area Compliance Laboratories Corp. (Shenzhen)

6/F, the 3rd Phase of WanLi Industrial Building,

ShiHua Road, FuTian Free Trade Zone

Shenzhen, Guangdong, China

Tel: +86-755-33320018

Fax: +86-755-33320008

Test Facility: Test facility was located at Pu Long Cun 69, Puxinghu Industrial

Area, Tangxia Town, Dongguan, Guangdong, P.R.China.

Accreditation: The NVLAP Lab Code is 200707-0.

Page 2: IES LM-79-08 - JLS- · PDF fileSTATEMENT: This test may not be duplicated or used in part without prior written consent from Bay Area Compliance Laboratories Corp. ... This report

Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian

Free Trade Zone Shenzhen, Guangdong, China

Report No. RSZ140305509-10 Page 2 of 12 The NVLAP Lab Code is 200707-0.

1. Product Description

General Information:

Sample No.: RSZ140305509-S01 Model: JLS68103-G100-SBCL. One sample was received on 2014-03-05 and used for testing.

Model Tested: JLS68103-G100-SBCL

Manufacturer: Jaykal LED Solutions, Inc

Brand Name: Jaykal LED Solutions, Inc

Product Designation: Outdoor Pole/Arm-Mounted Area and Roadway Luminaires

Burning Time Before Test: 0 hour(For New Products)

Rated Values:

Rated Voltage/Frequency: 100-277 VAC 50/60Hz

Rated Power: 100W

Nominal CCT: 5500K

Nominal CRI: 75

2. Standards Used

IESNA LM-79-08: Approved Method: Electrical & Photometric Measurement of Solid-state Lighting Products

ANSI C82.77-2002: Harmonic Emission Limits – Related Power Quality Requirements for Lighting

3. Description of Test Equipment

Device Manufacture Model No Serial No Test Range Calibration date

1.5m temperature

integrating sphere SENSING SPR-600 S09008 25~50℃ N/A

Spectral radiation analyzer SENSING SPR3000 90902027 350nm~800nm N/A

Digital power meter YOKOGAWA WT-210 91j926132 15/30/60/150/300/60

0 V 2013-03-25

Precision frequency power

supply ALL Power APW-105N 970613 0V-300V 50-400Hz 2013-03-25

Standard Light Source SENSING N/A LSD090808 N/A 2013-05-13

Temperature/humidity/cloc

k Victor VC230 EE209 0~40℃0~90% 2013-04-01

Programmable Precision

DC Power Supply ITECH IT6154

0061 0417

6471 0010 19 0~60V 2013-03-25

AC POWER SUPPLY EVERFINE VPS1060 PWM 1101006 0-150V, 0-300V 2013-03-25

Digital CC&CV DC Power

Supply EVERFINE WY12010 1009009 30V/5A 2013-03-25

Electrical parameter tester YOKOGAWA WT-210 91KB35700 15/30/60/150/300/60

0 V 2013-03-25

full-field speed

goniophotometer EVERFINE GO-R5000

YG108492N1

0120001 1600mm,3000W/10A N/A

Temperature/humidity/cloc

k Victor VC230 EE091 0~40℃0~90% 2013-04-01

Standard Light Source EVERFINE D908 1012001 N/A 2013-05-28

Page 3: IES LM-79-08 - JLS- · PDF fileSTATEMENT: This test may not be duplicated or used in part without prior written consent from Bay Area Compliance Laboratories Corp. ... This report

Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian

Free Trade Zone Shenzhen, Guangdong, China

Report No. RSZ140305509-10 Page 3 of 12 The NVLAP Lab Code is 200707-0.

Statement of Traceability: Bay Area Compliance Laboratories Corp. (Shenzhen) attested that all calibration has been

performed using suitable standards traceable to National Primary Standards and International System of Units (SI).

4. Test Method

Product was tested with no seasoning. All stabilization and measurements were made in compliance with IES LM-79-08. The product was operated at rated voltage or at voltage required by manufacturer. The ambient temperature of the sample was maintained at 25°C±1°C during measurement. And relative humidity is less than 65%.

Integrating Sphere System

The system includes AC power source, digital power meter, DC power supply, spectrophotometer, and integrating sphere. The integrating sphere system is calibrated by standard light source before measurement. The system and standard light source has been calibrated regularly and traceable to the National Primary Standards.

4π geometry was used during measurement. The product was operated in its intended orientation in application and was recorded in this report.

The uncertainty of the light output (luminous flux) measurements is U=1.64% (K=2), at the 95% confidence level. The

uncertainty of the correlated color temperature measurements is U=21K (K=2), at the 95% confidence level. The

uncertainty of the CRI is U=1.6 (K=2) , at the 95% confidence level.

Goniophotometer System

The goniophotometer system is calibrated by standard light source before measurement. The standard light source has been calibrated regularly and traceable to the National Primary Standards.

Type C goniophotometer was used for measuring total luminous flux, luminous intensity distribution, and color spatial uniformity. The product was operated in its intended orientation in application and was recorded in this report.

The uncertainty of the luminous intensity is U=2.82% (K=2) , at the 95% confidence level.

Additional Test

The Additional Test item may not be covered by IESNA LM-79-2008. Additional test including power factor, off-state power and THD, was measured by Digital Power Meter after stabilized at 25°C±1°C.Test voltage for THD and power factor test would be equal to rated voltage or, in case of a voltage range, maximum value of that range.

The uncertainty of power meter AC current U=0.19 % of rdg, AC Voltage U=0.15% of rdg, Power U=0.20%) (K=2), at

the 95% confidence level.

Page 4: IES LM-79-08 - JLS- · PDF fileSTATEMENT: This test may not be duplicated or used in part without prior written consent from Bay Area Compliance Laboratories Corp. ... This report

Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian

Free Trade Zone Shenzhen, Guangdong, China

Report No. RSZ140305509-10 Page 4 of 12 The NVLAP Lab Code is 200707-0.

5. Test Result

[Integrating Sphere System]

Total operating time for integrating sphere test: 1.5 hours

Test orientation: Downward

Electrical Measurement

Voltage (V) Frequency (Hz) Current (A) Power (W) Power Factor

119.97 60.0 0.8256 98.59 0.995

Photometric Measurement

Luminous Flux (lm) Radiant Flux (W) Efficacy (lm/W) CCT (K) Duv

7624.354 20.142 77.334 5724 7.28E-03

Chromaticity Coordinate

x y u v u' v'

0.3272 0.3509 0.1996 0.3211 0.1996 0.4817

Color Rendering Index

Ra

72.2

R1 R2 R3 R4

69 75 82 74

R5 R6 R7 R8

72 69 79 58

R9 R10 R11 R12

-33 44 74 55

R13 R14 R15

70 90 62

Page 5: IES LM-79-08 - JLS- · PDF fileSTATEMENT: This test may not be duplicated or used in part without prior written consent from Bay Area Compliance Laboratories Corp. ... This report

Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian

Free Trade Zone Shenzhen, Guangdong, China

Report No. RSZ140305509-10 Page 5 of 12 The NVLAP Lab Code is 200707-0.

Relative Spectral Power Distribution

nm mW

nm mW

nm mW

nm mW

nm mW

380 1.064E-02 465 1.644E-01 550 5.306E-01 635 2.465E-01 720 2.625E-02

385 6.254E-03 470 1.346E-01 555 5.341E-01 640 2.213E-01 725 2.273E-02

390 4.359E-03 475 1.333E-01 560 5.368E-01 645 1.973E-01 730 1.978E-02

395 4.764E-03 480 1.490E-01 565 5.345E-01 650 1.748E-01 735 1.759E-02

400 6.712E-03 485 1.819E-01 570 5.298E-01 655 1.550E-01 740 1.502E-02

405 1.365E-02 490 2.263E-01 575 5.233E-01 660 1.372E-01 745 1.317E-02

410 3.146E-02 495 2.731E-01 580 5.093E-01 665 1.212E-01 750 1.159E-02

415 7.340E-02 500 3.169E-01 585 4.949E-01 670 1.056E-01 755 1.034E-02

420 1.568E-01 505 3.570E-01 590 4.792E-01 675 9.287E-02 760 8.993E-03

425 2.980E-01 510 3.920E-01 595 4.576E-01 680 8.198E-02 765 8.137E-03

430 5.008E-01 515 4.195E-01 600 4.326E-01 685 7.090E-02 770 7.113E-03

435 7.517E-01 520 4.440E-01 605 4.117E-01 690 6.130E-02 775 6.471E-03

440 9.459E-01 525 4.623E-01 610 3.846E-01 695 5.304E-02 780 5.961E-03

445 8.146E-01 530 4.809E-01 615 3.572E-01 700 4.632E-02 785 5.378E-03

450 5.160E-01 535 4.949E-01 620 3.280E-01 705 4.010E-02 790 4.952E-03

455 3.274E-01 540 5.096E-01 625 2.991E-01 710 3.457E-02 795 4.526E-03

460 2.342E-01 545 5.213E-01 630 2.721E-01 715 3.020E-02 800 4.175E-03

0.0

0.2

0.4

0.6

0.8

1.0

1.2

380 440 500 560 620 680 740 800

Page 6: IES LM-79-08 - JLS- · PDF fileSTATEMENT: This test may not be duplicated or used in part without prior written consent from Bay Area Compliance Laboratories Corp. ... This report

Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian

Free Trade Zone Shenzhen, Guangdong, China

Report No. RSZ140305509-10 Page 6 of 12 The NVLAP Lab Code is 200707-0.

CIE 1931 x y Chromaticity Diagram

7-Step & 4-Step Chromaticity Quadrangles

0

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

0.9

0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8

0.30

0.35

0.40

0.45

0.30 0.35 0.40 0.45 0.50

sample

7-STEP 2700K

7-STEP 3000K

7-STEP 3500K

7-STEP 4000K

7-STEP 4500K

7-STEP 5000K

7-STEP 5700K

7-STEP 6500K

4-STEP 2700K

4-STEP 3000K

4-STEP 3500K

4-STEP 4000K

4-STEP 5000K

4-STEP 6500K

Page 7: IES LM-79-08 - JLS- · PDF fileSTATEMENT: This test may not be duplicated or used in part without prior written consent from Bay Area Compliance Laboratories Corp. ... This report

Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian

Free Trade Zone Shenzhen, Guangdong, China

Report No. RSZ140305509-10 Page 7 of 12 The NVLAP Lab Code is 200707-0.

[Goniophotometer System]

Total operating time for luminous intensity distribution: 1.5 hours

Test orientation: Downward

Electrical Measurement

Input Voltage (V) Frequency (Hz) Input Current (A) Power (W) Power Factor

120.1 60.0 0.8213 98.09 0.9945

Photometric Measurement

Luminous Flux (lm) Efficacy (lm/W) CBCP (cd) S/MH (C0/180) S/MH (C90/270)

7646.77 77.96 2759 1.34 1.37

Luminous Intensity Distribution

C0/180 C45/225 C90/270 C135/315 AVG.

Beam Angle (50% Imax): 116.3 111.5 108.1 111.5 111.9

Field Angle (10% Imax): 147.1 144.5 144.5 145.9 145.5

Page 8: IES LM-79-08 - JLS- · PDF fileSTATEMENT: This test may not be duplicated or used in part without prior written consent from Bay Area Compliance Laboratories Corp. ... This report

Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian

Free Trade Zone Shenzhen, Guangdong, China

Report No. RSZ140305509-10 Page 8 of 12 The NVLAP Lab Code is 200707-0.

Luminous Intensity (cd) Distribution Data

C

0° 22.5° 45° 67.5° 90° 112.5° 135° 157.5° γ

0.0° 2759 2756 2757 2756 2754 2756 2753 2752

5.0° 2752 2758 2764 2768 2766 2766 2761 2756

10.0° 2729 2740 2754 2761 2763 2764 2757 2744

15.0° 2690 2707 2725 2736 2748 2747 2733 2716

20.0° 2637 2660 2683 2866 2920 2914 2693 2672

25.0° 2567 2592 2773 2556 2616 2623 2791 2613

30.0° 2478 2507 2534 2467 2536 2532 2592 2533

35.0° 2370 2411 2348 2395 2430 2434 2387 2438

40.0° 2226 2416 2234 2288 2305 2310 2266 2428

45.0° 1858 2064 2116 2134 2151 2171 2154 2281

50.0° 1699 1715 1928 1940 1968 1990 1998 1828

55.0° 1504 1506 1523 1723 1746 1773 1656 1583

60.0° 1272 1269 1283 1390 1211 1478 1383 1351

65.0° 858 907 1000 922 939 980 1105 979

70.0° 500 484 470 505 533 595 583 549

75.0° 157 164 150 155 172 188 223 231

80.0° 41 41 38 41 46 54 55 53

85.0° 6 7 9 10 12 11 10 10

90.0° 0 0 0 0 0 0 0 0

95.0° 0 0 0 0 0 0 0 0

100.0° 0 0 0 0 0 0 0 0

105.0° 0 0 0 0 0 0 0 0

110.0° 0 0 0 0 0 0 0 0

115.0° 0 0 0 0 0 0 0 0

120.0° 0 0 0 0 0 0 0 0

125.0° 0 0 0 0 0 0 0 0

130.0° 0 0 0 0 0 0 0 0

135.0° 0 0 0 0 0 0 0 0

140.0° 0 0 0 0 0 0 0 0

145.0° 0 0 0 0 0 0 0 0

150.0° 0 0 0 0 0 0 0 0

155.0° 0 0 0 0 0 0 0 0

160.0° 0 0 0 0 0 0 0 0

165.0° 0 0 0 0 0 0 0 0

170.0° 0 0 0 0 0 0 0 0

175.0° 0 0 0 0 0 0 0 0

180.0° 0 0 0 0 0 0 0 0

Page 9: IES LM-79-08 - JLS- · PDF fileSTATEMENT: This test may not be duplicated or used in part without prior written consent from Bay Area Compliance Laboratories Corp. ... This report

Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian

Free Trade Zone Shenzhen, Guangdong, China

Report No. RSZ140305509-10 Page 9 of 12 The NVLAP Lab Code is 200707-0.

Luminous Intensity (cd) Distribution Data (cont.)

C

180° 202.5° 225° 247.5° 270° 292.5° 315° 337.5° γ

0.0° 2759 2756 2757 2756 2754 2756 2753 2752

5.0° 2754 2746 2743 2740 2735 2736 2736 2740

10.0° 2737 2724 2711 2703 2697 2699 2703 2709

15.0° 2699 2680 2661 2650 2639 2644 2652 2665

20.0° 2648 2621 2599 2581 2568 2571 2588 2605

25.0° 2582 2548 2521 2502 2491 2489 2507 2532

30.0° 2497 2460 2420 2392 2384 2393 2414 2440

35.0° 2392 2350 2317 2277 2248 2278 2297 2325

40.0° 2263 2217 2179 1888 1762 1910 2164 2198

45.0° 1952 2051 2019 1642 1627 1636 1999 1825

50.0° 1731 1694 1533 1490 1475 1491 1538 1668

55.0° 1537 1498 1278 1313 1297 1319 1235 1484

60.0° 1298 1282 1057 1117 1094 1122 1055 1259

65.0° 941 816 838 754 675 790 840 852

70.0° 518 430 494 415 418 411 493 434

75.0° 207 183 157 154 149 172 161 185

80.0° 45 38 43 44 30 44 41 38

85.0° 9 9 9 8 8 8 8 7

90.0° 0 0 0 0 0 0 0 0

95.0° 0 0 0 0 0 0 0 0

100.0° 0 0 0 0 0 0 0 0

105.0° 0 0 0 0 0 0 0 0

110.0° 0 0 0 0 0 0 0 0

115.0° 0 0 0 0 0 0 0 0

120.0° 0 0 0 0 0 0 0 0

125.0° 0 0 0 0 0 0 0 0

130.0° 0 0 0 0 0 0 0 0

135.0° 0 0 0 0 0 0 0 0

140.0° 0 0 0 0 0 0 0 0

145.0° 0 0 0 0 0 0 0 0

150.0° 0 0 0 0 0 0 0 0

155.0° 0 0 0 0 0 0 0 0

160.0° 0 0 0 0 0 0 0 0

165.0° 0 0 0 0 0 0 0 0

170.0° 0 0 0 0 0 0 0 0

175.0° 0 0 0 0 0 0 0 0

180.0° 0 0 0 0 0 0 0 0

Page 10: IES LM-79-08 - JLS- · PDF fileSTATEMENT: This test may not be duplicated or used in part without prior written consent from Bay Area Compliance Laboratories Corp. ... This report

Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian

Free Trade Zone Shenzhen, Guangdong, China

Report No. RSZ140305509-10 Page 10 of 12 The NVLAP Lab Code is 200707-0.

Average Area Illumination Figure

Height (m) Diameter

(cm) Eavg(lx) Emax(lx)

0.5 147.8 3502.0 11035.0

1.0 296.0 875.4 2759.0

1.5 443.5 389.1 1226.0

2.0 591.9 218.9 689.7

2.5 739.2 140.1 441.4

3.0 887.9 97.3 306.5

3.5 1034.9 71.5 225.2

4.0 1183.8 54.7 172.4

4.5 1330.5 43.2 136.2

5.0 1479.8 35.0 110.3

Angle: 111.9°. Flux out: 6045.0 lm.

Page 11: IES LM-79-08 - JLS- · PDF fileSTATEMENT: This test may not be duplicated or used in part without prior written consent from Bay Area Compliance Laboratories Corp. ... This report

Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian

Free Trade Zone Shenzhen, Guangdong, China

Report No. RSZ140305509-10 Page 11 of 12 The NVLAP Lab Code is 200707-0.

Zonal Lumen Density Measurement

Deg Flux (lm) %

Deg Flux (lm) %

0-5 65.8 0.86 0-5 65.8 0.86

5-10 196.2 2.57 0-10 262.0 3.43

10-15 321.8 4.20 0-15 583.7 7.63

15-20 442.5 5.79 0-20 1026.3 13.42

20-25 551.5 7.21 0-25 1577.7 20.63

25-30 641.0 8.39 0-30 2218.8 29.02

30-35 710.3 9.28 0-35 2929.0 38.30

35-40 759.9 9.94 0-40 3688.9 48.24

40-45 772.6 10.11 0-45 4461.6 58.35

45-50 748.3 9.78 0-50 5209.9 68.13

50-55 701.6 9.18 0-55 5911.5 77.31

55-60 636.7 8.32 0-60 6548.2 85.63

60-65 521.9 6.83 0-65 7070.2 92.46

65-70 346.7 4.53 0-70 7416.9 96.99

70-75 164.8 2.16 0-75 7581.7 99.15

75-80 50.7 0.66 0-80 7632.4 99.81

80-85 12.0 0.16 0-85 7644.4 99.97

85-90 1.9 0.02 0-90 7646.3 99.99

90-95 0.0 0.00 0-95 7646.3 99.99

95-100 0.0 0.00 0-100 7646.4 99.99

100-105 0.0 0.00 0-105 7646.4 99.99

105-110 0.0 0.01 0-110 7646.4 100.00

110-115 0.0 0.00 0-115 7646.4 100.00

115-120 0.0 0.00 0-120 7646.5 100.00

120-125 0.0 0.00 0-125 7646.5 100.00

125-130 0.0 0.00 0-130 7646.5 100.00

130-135 0.0 0.00 0-135 7646.6 100.00

135-140 0.0 0.00 0-140 7646.6 100.00

140-145 0.0 0.00 0-145 7646.6 100.00

145-150 0.0 0.00 0-150 7646.7 100.00

150-155 0.0 0.00 0-155 7646.7 100.00

155-160 0.0 0.00 0-160 7646.7 100.00

160-165 0.0 0.00 0-165 7646.7 100.00

165-170 0.0 0.00 0-170 7646.8 100.00

170-175 0.0 0.00 0-175 7646.8 100.00

175-180 0.0 0.00 0-180 7646.8 100.00

Page 12: IES LM-79-08 - JLS- · PDF fileSTATEMENT: This test may not be duplicated or used in part without prior written consent from Bay Area Compliance Laboratories Corp. ... This report

Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian

Free Trade Zone Shenzhen, Guangdong, China

Report No. RSZ140305509-10 Page 12 of 12 The NVLAP Lab Code is 200707-0.

[Additional Test]

Test Item Test Voltage (V) Frequency (Hz) Test Result

Power Factor: 277 60 0.952

Total Harmonic Distortion: 277 60 10.5%

Total Harmonic Distortion: 120 60 6.4%

Off State Power (W): 120 60 0.0

6. Product Photo

***********END OF REPORT***********