incontrol mwrg folder e

4
Meltem Wärmerückgewinnung GmbH & Co. KG Am Hartholz 4 · D-82239 Alling Telephone: +49 (0) 8141 / 40 41 79 - 0 Fax: +49 (0) 8141 / 40 41 79 - 9 [email protected] · www.meltem.com VENTILATION AND HEAT RECOVERY Meltem is a leading manufacturer of decentralised ventilation and heat recovery systems in Europe. With innovative solutions, Meltem provides for fresh and clean air so that you can feel well all-round at home or in your professional environment. Installation note: M-WRG and push-button are connected via a 16-pin data cable, e.g. J-Y(ST)Y 8 x 2 x 0.6 Article no. Article designation Description 5006-1-1 M-WRG-S/Z-T Ventilation unit for connecting to a six-fold push-button 5006-1-1-1 M-WRG-S/Z-T-F Ventilation with humidity control for connect- ing to a six-fold push-button 5006-1-1-2 M-WRG-S/Z-T-FC Ventilation unit with humidity and CO2 control for connecting to a six-fold push-button 5047-00 M-WRG-T/WS six-fold push-button with red LED, white 5047-10 M-WRG-T/ES six-fold push-button with red LED, stainless steel 5047-20 M-WRG-T/AL six-fold push-button with red LED, brushed aluminium saleaway 5315-21 KW 01/2013 Clean air. GREEN TECHNOLOGY. M-WRG-S/Z-T M-WRG-S/Z-T-F M-WRG-S/Z-T-FC CO2

Upload: alina-voinea

Post on 18-Jul-2016

16 views

Category:

Documents


2 download

DESCRIPTION

INSTALATII

TRANSCRIPT

Page 1: Incontrol MWRG Folder E

Meltem Wärmerückgewinnung GmbH & Co. KG

Am Hartholz 4 · D-82239 AllingTelephone: +49 (0) 8141 / 40 41 79 - 0Fax: +49 (0) 8141 / 40 41 79 - 9

[email protected] · www.meltem.com

VENTILATION AND HEAT RECOVERY

Meltem is a leading manufacturer of decentralised

ventilation and heat recovery systems in Europe.

With innovative solutions, Meltem provides for

fresh and clean air so that you can feel well all-round

at home or in your professional environment.

Installation note: M-WRG and push-button are connected via a 16-pin data cable, e.g. J-Y(ST)Y 8 x 2 x 0.6

Article no. Article designation Description

5006-1-1 M-WRG-S/Z-TVentilation unit for connecting to a six-fold push-button

5006-1-1-1 M-WRG-S/Z-T-FVentilation with humidity control for connect-ing to a six-fold push-button

5006-1-1-2 M-WRG-S/Z-T-FCVentilation unit with humidity and CO2 control for connecting to a six-fold push-button

5047-00 M-WRG-T/WS six-fold push-button with red LED, white

5047-10 M-WRG-T/ES six-fold push-button with red LED, stainless steel

5047-20 M-WRG-T/ALsix-fold push-button with red LED, brushed aluminium

sale

away

5

315-

21

KW

01/

2013

Clean air. GREEN TECHNOLOGY.

M-WRG-S/Z-T M-WRG-S/Z-T-F M-WRG-S/Z-T-FC

CO2

Page 2: Incontrol MWRG Folder E

Ventilation with heat recovery was never this SIMPLE.

COMFORT HOME VENTILATION WITH HEAT RECOVERY

InControl

VENTILATION THE RIGHT WAY

VENTILATION AND HEAT RECOVERY

CO2

sale

away

5

315-

21

KW

01/

2013

Page 3: Incontrol MWRG Folder E

InControl

2 VENTILATION THE RIGHT WAY

JUST A PUSH OF A BUTTON

As simple as never before, the InControl control

unit can be used to quickly and easily operate your

Meltem ventilation unit with heat recovery accord-

ing to your personal preferences. A simple push of

the button is enough to convert to summer opera-

tion or to set the ventilation to moisture protection

(e.g. during longer absences). Because the ventila-

tion unit is connected via a data cable, the control

unit is independent from the installation location of

the unit. The integrated LEDs always inform about

the current ventilation conditions.

Diverse setting options

Opt

ions

for

hum

idity

and

CO

2 co

ntro

l

CO2

C O M F O R T A B L E C O N T R O L

Page 4: Incontrol MWRG Folder E

VENTILATION AND HEAT RECOVERY

3

ALL FUNCTIONS AT A GLANCE:

VENTILATION WHEN PRESENT (NORMAL OPERATION)This ventilation level (30 m3/h) represents normal operation in order to achieve the necessary

ventilation for hygienic and health requirements when the user is present.

INCREASED VENTILATIONIncreased ventilation (60 m3/h) to reduce peak loads, e.g. in the presence of multiple persons or

with increased unpleasant odours.

CO2 CONTROL / AIR QUALITY (OPTIONAL; TYPE: MWRG-S/Z-T-FC)The air quality (CO2 and various mixed gaseous pollutants) is monitored with a sensor and the

proper ventilation level is automatically set.CO2

Each button has a built-in light diode (LED) for displaying the set mode of operation. Upon

pressing the button again, the LED will turn off. If no LED light is shining, the ventilation unit is in standby mode.

EXHAUST AIR OPERATION (TYPE: MWRG-S/Z-T + MWRG-S/Z-T-F)Exhaust air operation with limited heat recovery. This type of operation can be selected to ventilate

stale air. If two ventilation units are available, it is possible to cross-ventilate in the structure by set

one unit to supply air operation and the other to exhaust air operation.

VENTILATION FOR MOISTURE PROTECT (OPTIONAL; TYPE: MWRG-S/Z-T-F + MWRG-S/Z-T-FC)If the relative inside humidity exceeds 60 %, the ventilation level will be continually increased up

to a maximum of 60 m3/h until the air humidity has again decreased to below 60 %. To ensure

dehumidification, the unit will compare the air humidity of supply air and exhaust air. A blinking LED

signalises that the air humidity of the supply air is greater than that of the ambient air and therefore,

dehumidification is not possible.

VENTILATION WHILE ABSENT (REDUCED VENTILATION)The ventilation unit runs at the lowest stage (15 m3/h). This mode of operation can be selected

for longer periods of absence on the part of the residents, e.g. holiday, in order to ensure a

minimum level of air exchange.

SUPPLY AIR OPERATION (SUMMER OPERATION)Supply air operation with limited heat recovery. By choosing this type of operation, e.g. on summer

nights, the cooler outside air can be directed into the structure.

BOOST VENTILATION (15 MINUTES)By pressing this button, the unit will switch to the maximum ventilation performance (100 m3/h).

After approx. 15 minutes or after pressing the button again, the boost ventilation will be

completed and the previously set ventilation will resume. The LED will shine throughout the boost

ventilation mode.