international waterstops for concretespec-kw.com/upload/international_waterstop_brochure_684.pdf ·...

8
Typical Structures Requiring Waterstops Include: Water and waste water treatment facilities Primary and secondary containment structures Tunnels and culv erts Dams, locks, canals, water reservoirs and aqueducts Pipe penetrations Swimming pools Storage tanks Retaining walls Foundations Slabs on grade 3400 Tree Court Industrial Boulev ard, St. Louis, Missouri 63122 Phone: 800. 325-9504 or 636. 225-9400 Fax: 800. 551-5145 or 636. 225-2049 www.Greenstreak.com INTERNATIONAL WATERSTOPS FOR CONCRETE Concrete structures are only as watertight as the waterstops that join them. Gr eenstreak waterstops stop leaks before they start... in the joints of concrete structures. Since 1950, Greenstreak has served the general and architectural concrete construction industry. Innovation, engineering and quality cr aftsmanship ar e combined to pr oduce pr oducts of choice for the industry’s owners, designers and contractors. Greenstreak maintains its position of industry leadership by responding to the unique needs of our customers. Greenstreak’s dedicated technical and customer service staffs are active participants in the concrete industry to take advantage of the latest technolog ical advances, communicate with our market and analyze tr ends. Centrally located, Greenstreak products are readily available through a dedicated network of Concrete Forming and Accessory Distri butors both nat ionally and internat ionally . Flexible solutions. Concrete performance. Hydroelectric and Flood Control Projects Water and Waste Water Treatment Plants Tel.: +965 1820044 - Fax: +965 24582548 www.spec-kw.com - [email protected]

Upload: trandiep

Post on 20-Feb-2018

218 views

Category:

Documents


0 download

TRANSCRIPT

Typical Structures Requiring Waterstops Include:Water and waste water treatment facilitiesPrimary and secondary containment structuresTunnels and culvertsDams, locks, canals, water reservoirs and aqueductsPipe penetrationsSwimming poolsStorage tanksRetaining wallsFoundationsSlabs on grade

3400 Tree Court Industrial Boulevard, St. Louis, Missouri 63122Phone: 800. 325-9504 or 636. 225-9400Fax: 800. 551-5145 or 636. 225-2049www.Greenstreak.com

INTERNATIONALWATERSTOPS FOR CONCRETE

Concrete structures are only as watertight as the waterstops thatjoin them. Greenstreak waterstops stop leaks before they start...in the joints of concrete structures. Since 1950, Greenstreak has served the general and architecturalconcrete construction industry. Innovation, engineering and quality craftsmanship are combined to produce products of choicefor the industry’s owners, designers and contractors. Greenstreak maintains its position of industry leadership byresponding to the unique needs of our customers. Greenstreak’sdedicated technical and customer service sta�s are active participants in the concrete industry to take advantage of thelatest technological advances, communicate with our marketand analyze trends. Centrally located, Greenstreak products are readily availablethrough a dedicated network of Concrete Forming andAccessory Distributors both nationally and internationally.

Flexible solutions. Concrete performance.

Hydroelectric and FloodControl Projects

Water and Waste Water Treatment Plants

Tel.: +965 1820044 - Fax: +965 24582548www.spec-kw.com - [email protected]

WATERSTOP BASIC USE

Embedded in concrete, across and/or alongthe joint, waterstops form a watertightdiaphragm that prevents the passage offluid through the joint.

SUGGESTED WATERSTOPDESIGN CHECKLIST

u Determine structure typeu Verify chemical containment

requirements (if any)u Verify hydrostatic head pressure

requirementsu Determine joint type and joint

movement requirementsu Verify joinery details of dissimilar or

non-symmetrical waterstop profiles(consider using one profile throughoutto simplify intersections)

u Specify ribbed profile for best watersealing performance

u Specify type and size (by product number, if possible)

u Specify factory fabrications of intersec-tions and heat welded field butt joints

u Specify method for securing waterstopin position (hog rings, grommets, etc.)

PVC WATERSTOP

u The industry standardu Broadest design selectionu Formulated and compounded by

Greenstreaku Manufactured by Greenstreak from

only prime resins and all virgin raw materials

u Great inherent elasticityu Resistant to many waterborne chemicalsu Heat weldableu Will not discolor concrete or produce

electrolytic actionu Suitable for above or below grade

applications

GREENSTREAK PVC Waterstop isavailable in two grades:

—Specification Grade (-40°F/-40°C)

This is the most utilized grade for standardconstruction projects. PVC SpecificationGrade, the industry standard, is maintainedin stock.

Independent laboratory tests are availablefor the following applicable standards:

u Corps of Engineers CRD-C572-74u Bureau of Reclamation C902

—Arctic Grade (-58°F/-50°C)

PVC Waterstop is specially formulated toretain its physical properties and perfor-mance in excessively cold environments.

Requirements available on order to meet:

u Ontario Hydro Standard M-264-81u Canadian General Standards Board

41-GP-35M Type II

SBR AND NEOPRENE RUBBER WATERSTOPS

Greenstreak offers SBR and Neoprene waterstops for applications requiring thephysical properties of rubber.

C A L L G R E E N S T R E A K ’ S T E C H N I C A L S E R V I C E D E PA R T M E N T F O R A S S I S TA N C E W I T H

2

Greenstreak Rubber WaterstopPhysical Properties

ASTM Styrene HighProperty Test Butadiene Tensile

Method (SBR) Neoprene*Tensile Strength

(PSI min) D 412 2,500 2,500

Tensile Strength @ 300% Modulus D 412 1,150 1,150(PSI min)

Ultimate Elongation, D412 450 450(% min)

Durometer, Shore A (+/- 5) D2240 65 65

Water Absorption, 7 Days CRD-C575 5 15at 70°C % Weight Change (% max)

Compression Set, D395 30 3022 hr. @ 70°C % of Original Deflection (max) (Method B)

Accelerated Aging, D57296 hrs. @ 70°C

% of Tensile Strength before 80 80aging (min)

% of Elongation 80 80before aging (min)

Ozone Resistance, 7 Days at 50PPHM D1149 No No@ 38°C, 20% Elong. Cracks Cracks

*Provides maximum resistance to ozone, sewage, oil and solvents

British Standards Test ResultsProperty Test Method Typical Value

Ultimate Tensile BS2782 Strength Method 320A > 15.0 N/mm2

Ultimate BS2782Elongation Method 320A > 325%

BS2782 Elastic Modulus Method 320A > 8.0 N/mm2

BS2782 Density Method 620A 1.38 +/- 5%

Hardness BS2782(Shore A) Method 365B 79 +/- 3

BS2782 Water Absortion Method 430A > 0.1%

Greenstreak PVC Waterstop Physical Properties

PROPERTY TEST TypicalMethod VALUE

Tensile strength ASTM D-638 2000 PSI Min.Ultimate Elongation ASTM D-638 300% Min.Specific gravity ASTM D-792 1.39Stiffness in flexure ASTM D-747 600 PSI Min.Hardness Shore A15 ASTM D-2240 80±3Low temperaturebrittleness @-35°F ASTM D-746 PassWater absorption ASTM D-570 .15% Max.Tensile strength AfterAccelerated extraction CRD-C-572 1850 PSI Min.Elongation AfterAccelerated extraction CRD-C-572 300% Min.Alkali Resistance• weight change CRD-C-572 .20% Max.• hardness change 2 Pts. MaxTear resistance *D624 395 lb./in.

SWELLSTOP TM WATERSTOP

A flexible butyl rubber and swellable claywaterproofing compound that swellsupon contact with water to form a longlasting compression seal in non-moving

concrete joints.

Swellstoprequires a 2”minimum clearcoverage fromthe face of theconcrete.

3

M AT E R I A L T Y P E A N D D E S I G N S E L E C T I O N

TYPES OF CONCRETE JOINTS

Contraction (Control) JointContraction joints are designed planes of weakness to control thelocation of cracks due to shrinkage of concrete.

Expansion (Isolation) JointExpansion joints separate or isolate abutting concrete structures(walls, slabs, footings columns) protecting them from compressive

stresses that may develop due to thermal expansion, settlement,creep, live load deflections, drying shrinkage or crush. Differentialmovement at these joints can be both lateral and transverse.

Construction JointConstruction joints are determined by interruptions in the place-ment of concrete.

Swellstop

Waterstop ApplicationsGrout ribs stop the loss of fines at splitbulkhead (end shutter)

Eyelets on 30 cm centers each side. Eyelets off-set sideto side for easy wire tie to reinforcing.“Sure Form”

Internal for construction joint Internal for expansion joint

External for construction jointExternal with crack inducerfor contraction joint

External for expansion jointExternal for construction jointwall-to-slab

External for construction jointwall-slab-wall

4

20 4 6 313 ID

40150

BrassEyelet

STYLE 951 STD. WT. 31.44 Kg/20 LM ROLL HEAD PRESS. 224 KPa

20 4 6 3.5

34040200

13 ID BrassEyelet

STYLE 952 STD. WT. 39.45 Kg/20 LM ROLL HEAD PRESS. 373 KPa

55 3

3.574.525

25050

17 ID BrassEyelet

STYLE 953 STD. WT. 42.16 Kg/16 LM ROLL HEAD PRESS. 448 KPa

30 10 18 ID 3

5550250

BrassEyelet

STYLE 954 STD. WT. 63.85 Kg/14 LM ROLL HEAD PRESS. 597 KPa

GSK#043Double Headed Nail

Tear Web

5

55

20 16

203

4.5

150

STYLE 923 STD. WT. 30.22 Kg/20 LM ROLL HEAD PRESS. 224 KPa

GSK#043Double Headed Nail

Tear Web

5 4.5

4040

20

2003

16

20

STYLE 924 STD. WT. 43.18 Kg/20 LM ROLL HEAD PRESS. 373 KPa

GSK#043Double Headed Nail

Tear Web

355

25

25

185550

250

STYLE 925 STD. WT. 43.78 Kg/16 LM ROLL HEAD PRESS. 448 KPa

GSK#043Double Headed Nail

35 5

20

550

1055

65

25

18

250

Tear Web

STYLE 926 STD. WT. 26.91 Kg/8 LM ROLL HEAD PRESS. 448 KPa

GroutRibs 36420

40150

BrassEyelet

STYLE 955 STD. WT. 30.12 Kg/20 LM ROLL HEAD PRESS. 224 KPa

GroutRibs20 4 6 3.5 3

4040200

BrassEyelet

STYLE 956 STD. WT. 39.20 Kg/20 LM ROLL HEAD PRESS. 373 KPa

GroutRibs25 4.5 7 3.5 3

5550250

BrassEyelet

STYLE 957 STD. WT.41.56 Kg/16 LM ROLL HEAD PRESS. 448 KPa

GroutRibs30 10 3

5550250

BrassEyelet

STYLE 958 STD. WT. 61.49 Kg/14 LM ROLL HEAD PRESS. 597 KPa

GSK#043Double Headed Nail

GroutRibs

3

20

16

54.5

55

150

STYLE 927 STD. WT. 26.48 Kg/20 LM ROLL HEAD PRESS. 224 KPa

GSK#043Double Headed Nail

GroutRibs

3

16

204.55

4040

200

STYLE 928 STD. WT. 39.42 Kg/20 LM ROLL HEAD PRESS. 373 KPa

GSK#043Double Headed Nail

GroutRibs 3

18

255

5

5550

250

STYLE 929 STD. WT. 39.87 Kg/16 LM ROLL HEAD PRESS. 448 KPa

GSK#043Double Headed Nail

GroutRibs 35 5

18

25

9550

330

STYLE 930 STD. WT. 48.62 Kg/16 LM ROLL HEAD PRESS. 522 KPa

“SURE-FORM” PVC Waterstops

Internal Style: Brass reinforced eyelets for easy wire tie to reinforcing bars.

FOR EXPANSION JOINTS FOR CONSTRUCTION/CONTRACTION JOINTS

External Style: Easy nail-in-place with special two-headed nail — or — lay on grade.FOR EXPANSION JOINTS

Note: All dimensions in (mm) and dimensions are nominal and subject to manufacturing tolerances.

Not to scale

FOR CONSTRUCTION/CONTRACTION JOINTS

03250/GRD

5

GSK#043Double Headed Nail

35525

3

25

18

125135

50

TearWeb

STYLE 931 STD. WT. 8.11 Kg/3 LM

Tear Web

225

1525

240

7

5050

STYLE 938 STD. WT. 49.72 Kg/18 LM ROLL HEAD PRESS. 299 KPa

STYLE 838 STD. WT. 52.48 Kg/32 LM ROLL HEAD PRESS. 448 KPa

25

10230

20 ID & 35 OD

STYLE 933 STD. WT. 51.19 Kg/12 LM ROLL HEAD PRESS. 448 KPa

20

10 13 ID & 23 OD 2.55

260

BrassEyelet

STYLE 936 STD. WT. 45.77 Kg/18 LM ROLL HEAD PRESS. 373 KPa

9.5

63.5 28.6

19

229

STYLE 700 STD. WT. 33.75 Kg/6 LM ROLL HEAD PRESS. 448 KPa

3.2 9.5 8 ID & 22.2 OD 16

152

STYLE 732 STD. WT. 42.86 Kg/18 LM ROLL HEAD PRESS. 373 KPa

3.2 9.5 12.7 ID & 25.4 OD

229

STYLE 735 STD. WT. 58.34 Kg/16 LM ROLL HEAD PRESS. 597 KPa

6.4 9.5 19 ID & 31.8 OD 3.2

229

STYLE 718 STD. WT. 43.76 Kg/14 LM ROLL HEAD PRESS. 597 KPa

STYLE 609 STD. WT. 9.60 Kg/3 LM Retrofit System

GroutRibs

15 522

50507

240

STYLE 937 STD. WT. 45.92 Kg/18 LM ROLL HEAD PRESS. 299 KPa

GroutRibs

25

10230

STYLE 932 STD. WT. 63.49 Kg/16 LM ROLL HEAD PRESS. 448 KPa

GroutRibs

20

10 5 2.5

250

BrassEyelet

STYLE 934 STD. WT. 47.16 Kg/20 LM ROLL HEAD PRESS. 373 KPa

3.95011348 22.2

432

STYLE 777 STD. WT. 73.67 Kg/18 LM ROLL SlabSpan

4.8 9.5 22.2 ID & 38.1 OD 6.4

229

STYLE 696 STD. WT. 39.44 Kg/10 LM ROLL HEAD PRESS. 523 KPa

22.2 12.7 12.7 ID & 31.8 OD 25.4

305

STYLE 712 STD. WT. 91.26 Kg/14 LM ROLL HEAD PRESS. 672 KPa

HEAD PRESS. 299 KPaSTYLE 703 STD. WT. 34.88 Kg/32 LM ROLL

6.4 12.7 22.2 ID & 38.1 ID 4.7

305

STYLE 713 STD. WT. 56.55 Kg/10 LM ROLL HEAD PRESS. 672 KPa

Additional PVC Waterstops

PVC WATERSTOPS

Note: GREENSTREAK manufactures over 100 waterstop profiles in addition to those illustrated in this catalog. If you do not see a profile for your application, contact us. All dimensions in (mm) and dimensions are nominal and subject to manufacturing tolerances.

Available as a system:• #609W6 Waterstop• #609B1 S.S. Batten Bar

2 per 3 meter length of waterstop

• #609S1 S.S. Anchor Bolt42 pcs. per 3 meter length of waterstop

• Epoxy Gel

Not to scale

203mm8"

6.4mm ID & 12.7mm OD1/4" ID & 1/2" OD

5mm13/64"

1/4" ID & 5/8" OD6.4mm ID & 15.9mm OD

6"152.4mm

3/16"4.7mm

1/8"3.2mm

1/8"3.2mm

PVC WATERSTOPS

3.2 4.7

152.43.2

6.4 ID & 15.9 OD

5 6.4 ID & 12.7 OD

203

6

RUBBER SHAPES

3/4"19mm

3/8" 9.5mm

6"152.4mm

7

3/4"19mm

3/8" 9.5mm

6"152.4mm

7

3/4"19mm3/8"

9.5mm

9"228.6mm

3/4"19mm3/8"

9.5mm

9"228.6mm

6"152.4mm

3/4" ID & 1-1/8" OD19mm ID & 28.6 mm OD

1/4"6.3mm

5/8"15.9mm

6"152.4mm

3/4" ID & 1-1/8" OD19mm ID & 28.6 mm OD

1/4"6.3mm

5/8"15.9mm

3/8"9.5mm

1"25.4mm

9"228.6mm

3/4" ID &1-1/2" OD19mm ID & 38.1 OD

7

3/8"9.5mm

1"25.4mm

9"228.6mm

3/4" ID &1-1/2" OD19mm ID & 38.1 OD

7

Neoprene Rubber

918 STD. WT. 1.51 lbs/ft 2.25 Kg/m

919 STD. WT. 2.20 lbs/ft 3.27 Kg/m

920 STD. WT. 1.22 lbs/ft 1.82 Kg/m

921 STD. WT. 2.90 lbs/ft 4.32 Kg/m

Styrene Butadiene Rubber (SBR)

902 STD. WT. 1.30 lbs/ft 1.93 Kg/m

903 STD. WT. 1.90 lbs/ft 2.83 Kg/m

904 STD. WT. 1.05 lbs/ft 1.55 Kg/m

906 STD. WT. 2.50 lbs/ft 3.70 Kg/m

6

PVC FABRICATIONS

Flat “T” Flat “L”Flat “X”

Vertical “X”Vertical “T” Vertical “L”

Vertical “X” Vertical “L” UnionVertical “T”

Rubber Unions (Vertical and Flat)

Note: Adhesive available for bonding rubber intersections (unions).

u Easy to use for straight butt joint splicingu Accommodates small and large size waterstopsu Teflon Pad prevents stickingu Lightweight, easy to useu Thermostatically controlledu 110 VAC. (220 VAC. optional)u Peel and stick covers (replaceable)

Field Splicing Irons

Factory Fabricated Waterstop Intersections

PVC waterstop splices, directionalchanges and intersections are criticalcomponents of a quality installation.Specifications requiring factory madefabrications are strongly recommended.Greenstreak can provide homogenousdirectional changes and intersections,leaving only the less difficult straightsplices to be welded in the field.

Splices, directional changes and intersections are achieved with premolded unions, fittings and a rubber adhesive kit.

RUBBER FITTINGS

356

152

356

25

356

102

#297152 mm heating bar

#21425 mm heating bar

#213102 mm heating bar

9.5

152.4

19

199.519

228.6

152.4

15.9 6.3 19 ID & 28.6 OD

152.4

228.6

15.9 6.3 19 ID & 28.6 OD

25.4 25.49.5 9.5

228.6 228.6

19 ID & 38.1 OD 19 ID & 38.1 OD

Note: All dimensions in (mm) and dimensions are nominal and subject to manufacturing tolerances.

9.5

152.419

9.5

3/4"19mm

S

1" 25.4mm

3/4"19mm

S

1" 25.4mm

Swellstop 594 STD. WT. 0.41 lbs/ft 0.61 Kg/m

Lockstop595 STD. WT. 0.48 lbs/ft 0.71 Kg/m

19

19

25.4

25.4

7

SHEET DRAIN OVERLAP

EDGE TERMINA TION

SLOPE DRAIN AWA YFROM STRUCTURE

FOR VERTICAL INST ALLATION ON CONCRETE OR MASONR Y

SHEET DRAIN, .42 in. (10.67mm) thick with 1 in.(25.4 mm), center-to-center peg spacing is designedfor vertical applications with high flow and moderatecompressive strength requirements.

SHEET DRAIN HS, .25 in. (6.35mm) thick with 1/2

in. (12.7mm), center-to-center peg spacing designedfor vertical applications with moderate flow andexceptional compressive strength requirements.

Sheet Drains

Basic Use: GREENSTREAK® DrainageSystems are lightweight, one sided planardrains. Geocomposite Sheet Drain enhanceswaterproofing systems by reducing hydro-static head pressure on subgrade or retain-ing wall structures. Geocomposite DeckDrain provides horizontal planar drainagefor storm water control under pavers.

Advantagesu Reduces hydrostatic pressure and loadsu Reduces deadload on horizontal decks

by replacing aggregateu Eliminates drainage aggregate stockpiles

on tight job sitesu Minimizes freeze-thaw damageu Lightweight and easy to installu More economical than aggregateu Enhances waterproofing systemsu Protection board for membrane

waterproofingu Easy to ship, transport and store

Deck Drain

DECK DRAIN, .43 in. (10.92mm) thick with 1 in.(25.4mm), center-to-center peg spacing, is designedfor horizontal applications with exceptional flow andhigh compressive strength requirements. DECK DRAINis a sturdy product that withstands rough handlingand abrasion due to thermal expansion and contrac-tion of deck materials. DECK DRAIN may also be usedfor vertical applications where soil conditions dictate amore open filter fabric.

Form Release 7000

Form Release 7000 is specially formulated toprevent concrete from bonding to aluminum,steel, plywood and plastic forms and form liners. Form Release 7000 should be usedwith all reusable Greenstreak Form Liners.

Advantages

u Will not stain gray or white concreteu Will not impair bonding ability of paints,

epoxies or other coatings

u Rust inhibitors help prevent stains inconcrete and deterioration of forms

u Minimizes form clean-upu Lengthens life of wooden formsCoverageu 300-400% higher than most

premium releasesu Steel, aluminum, plastic, high density

plywood…3000-4000 ft2/ gal.

u Plywood, concrete…1000-1500 ft2/ gal.u Rough sawn, dimensional, striated

plywood…800-1000 ft2/ gal.

Technical

u Consists of fatty wood derivatives in alight amber clear hydrocarbon carrier

u Contains no lubricating oil, diesel oil,conventional form oil or kerosene

u Red label not required

3400 Tree Court Industrial Blvd., St. Louis, Missouri 63122 U.S.A.Phone: 800. 325-9504 or 636. 225-9400 • Fax: 800. 551-5145 or 636. 225-9854www.Greenstreak.com email: [email protected]

Printed in U.S.A.08/08

LIMITED WARRANTY: GREENSTREAK® warrants to the Buyer that this product will be free from defects and will perform as represented in writing subject to the two (2) following conditions:

First, the application of the product and the concrete construction practices used in the application are in accordance with GREENSTREAK®’s recommendations; and,

Second, the Buyer has selected the proper product for the specific application required. GREENSTREAK® disclaims any responsibility for the selection of a particular waterstop product. Product selection is the sole responsibility and decision of the Buyer. The suitability of any material for a specific application requiring fluid resistance is best determined by specific testing for the application. GREENSTREAK® urges the Buyer to conductits own site application testing.

Any information supplied by GREENSTREAK® with respect to its products is believed to be correct. GREENSTREAK® makes no representations or warranties, express or implied, as to the accuracy or completeness of suchinformation or the use of such information for a particular purpose. GREENSTREAK® has not performed any tests. Any test data has been prepared by independent commercial laboratories.

Because GREENSTREAK® has no control over either the application or the selection of its products, GREENSTREAK®’s Limited Warranty is as follows:

The exclusive remedies of the Buyer and the limit of the liability of GREENSTREAK® from any and all losses or damages resulting from the use of this product (including claims based oncontract, negligence, strict liability, or otherwise) shall be either the full refund of the purchase price to Buyer of this product or the replacement of the quantity of product purchased by theBuyer – at the election of GREENSTREAK®. In no event shall GREENSTREAK® be liable for any incidental or consequential damages. The Buyer and all users of this product are deemed tohave accepted the terms of this Limited Warranty which may not be varied in any way by any verbal or written agreement.

Architectural Concrete

FORM LINERSForm Follows Function Greenstreak® Architectural Concrete Form Linersmake it easy to pour interesting detail into a structure…without pouring in a lot of money.

Greenstreak Form liners are available in severalgrades and are ideal for texturing tilt-up, cast-in-place and precast concrete.

Greenstreak Form Liners are attached to the forming system or casting bed prior to concreteplacement. After normal placement and curingtime, the form work and liner are stripped, leavingan architectural finish in the concrete.

Just a few Greenstreak patterns are shownin this catalog. Call Greenstreak for addi-tional pattern details or if you would likeus to create a custom pattern or design.

# 360

# 337

# 373

# 351

# 302