intra interfreq interrat paramters

88
List RNC Oriented Intra-frequency Handover Measurement Algorithm Parameters --------------------------------------------------------------------------- 1F event absolute EcNo threshold[dB] -24 1F event absolute RSCP threshold[dBm] <NULL> Intra-freq meas L3 filter coeff D3 Intra-freq Measure Quantity CPICH_EC/NO 1A event to periodical rpt number D16 1A event to periodical rpt period[ms] D4000 1C event to periodical rpt number D16 1C event to periodical rpt period[ms] D4000 1J event to periodical rpt number D64 1J event to periodical rpt period[ms] D1000 VP service 1A event relative THD[0.5dB] 6 CS non VP service 1A event relative THD[0.5dB] 6 PS service 1A event relative threshold[0.5dB] 6 VP service 1B event relative THD[0.5dB] 12 CS non VP service 1B event relative THD[0.5dB] 12 PS service 1B event relative threshold[0.5dB] 12 1A hysteresis[0.5dB] 0 1B hysteresis[0.5dB] 0 1C hysteresis[0.5dB] 8 1D hysteresis[0.5dB] 8 1F hysteresis[0.5dB] 8 1J hysteresis[0.5dB] 8 Weighted factor 0 1A event trigger delay time[ms] D320 1B event trigger delay time[ms] D640 1C event trigger delay time[ms] D640 1D event trigger delay time[ms] D640 1F event trigger delay time[ms] D640 1J event trigger delay time[ms] D640 Max evaluation period of SHO failure[s] 60 Threshold number of SHO failure 3 Relative threshold of SHO failure[dB] 2 Period of penalty timer for SHO failure after down rate[s] 30 Min quality THD for SHO[dB] -24 Max number of cell in active set 3 1F event blind handover trigger condition[dBm] -115 Intrafrequency measurement report interval of blind HO[ms] D250 Intrafrequency measurement report amount of blind handover D2

Upload: aykut-yilmaz

Post on 22-Nov-2015

43 views

Category:

Documents


0 download

TRANSCRIPT

Intra_FreqList RNC Oriented Intra-frequency Handover Measurement Algorithm Parameters---------------------------------------------------------------------------1F event absolute EcNo threshold[dB]-241F event absolute RSCP threshold[dBm]Intra-freq meas L3 filter coeffD3Intra-freq Measure QuantityCPICH_EC/NO1A event to periodical rpt numberD161A event to periodical rpt period[ms]D40001C event to periodical rpt numberD161C event to periodical rpt period[ms]D40001J event to periodical rpt numberD641J event to periodical rpt period[ms]D1000VP service 1A event relative THD[0.5dB]6VP = VideoCS non VP service 1A event relative THD[0.5dB]6CS non VP = AMR voicePS service 1A event relative threshold[0.5dB]6PS = R99, HSPAVP service 1B event relative THD[0.5dB]12VP = VideoCS non VP service 1B event relative THD[0.5dB]12CS non VP = AMR voicePS service 1B event relative threshold[0.5dB]12PS = R99, HSPA1A hysteresis[0.5dB]01B hysteresis[0.5dB]01C hysteresis[0.5dB]81D hysteresis[0.5dB]81F hysteresis[0.5dB]81J hysteresis[0.5dB]8Weighted factor01A event trigger delay time[ms]D3201B event trigger delay time[ms]D6401C event trigger delay time[ms]D6401D event trigger delay time[ms]D6401F event trigger delay time[ms]D6401J event trigger delay time[ms]D640Max evaluation period of SHO failure[s]60Threshold number of SHO failure3Relative threshold of SHO failure[dB]2Period of penalty timer for SHO failure after down rate[s]30Min quality THD for SHO[dB]-24Max number of cell in active set31F event blind handover trigger condition[dBm]-115Intrafrequency measurement report interval of blind HO[ms]D250Intrafrequency measurement report amount of blind handoverD2

Inter_FreqO&M #4904647%%LST INTERFREQHOCOV:;%%RETCODE = 0 Execution succeeded.List RNC Oriented Coverage based Inter-frequency Handover Measurement Algorithm Parameters------------------------------------------------------------------------------------------Inter-frequency measure periodical rpt period[ms]D5002B hysteresis[0.5dB]2B event trigger delay time[ms]F1 -> F3F3 ->F1Inter-freq CS measure start Ec/No THD[dB]-11[-24, 0]-9-9Inter-freq CS measure stop Ec/No THD[dB]-8[-24, 0]-6-6Inter-freq CS measure start RSCP THD[dBm]-100[-115, -25]-90-90Inter-freq CS measure stop RSCP THD[dBm]-95[-115, -25]-85-85Inter-freq H measure start Ec/No THD[dB]-15[-24, 0]-9-13Inter-freq R99 PS measure start Ec/No THD[dB]-15[-24, 0]-9-13Inter-freq H measure stop Ec/No THD[dB]-12[-24, 0]-6-11Inter-freq R99 PS measure stop Ec/No THD[dB]-12[-24, 0]-6-11Inter-freq H measure start RSCP THD[dBm]-110[-115, -25]-90-105Inter-freq R99 PS measure start RSCP THD[dBm]-110[-115, -25]-90-105Inter-freq H measure stop RSCP THD[dBm]-105[-115, -25]-85-100Inter-freq R99 PS measure stop RSCP THD[dBm]-105[-115, -25]-85-100Inter-freq H target frequency trigger Ec/No THD[dB]-12[-24, 0]-12-12Inter-freq R99 PS target frequency trigger Ec/No THD[dB]-12[-24, 0]-12-12Inter-freq H target frequency trigger RSCP THD[dBm]-105[-115, -25]-105-105Inter-freq R99 PS target frequency trigger RSCP THD[dBm]-105-105-105Inter-freq H Used frequency trigger Ec/No THD[dB]-15Inter-freq R99 PS Used frequency trigger Ec/No THD[dB]-15Inter-freq H Used frequency trigger RSCP THD[dBm]-110Inter-freq R99 PS Used frequency trigger RSCP THD[dBm]-1102B event retry max timesHHO hysteresis[0.5dB]02B event retry period[500ms]HHO period trigger delay time[ms]0Inter-frequency measure report modePeriodical reportingInter-frequency measure filter coeffD32D hysteresis[0.5dB]02F hysteresis[0.5dB]0Weight for Used frequency02D event trigger delay time[ms]D3202F event trigger delay time[ms]D1280Inter-freq CS target frequency trigger Ec/No THD[dB]-8>3220-14Inter-freq CS target frequency trigger RSCP THD[dBm]-85>3040-75Inter-freq CS Used frequency trigger Ec/No THD[dB]-11Inter-freq CS Used frequency trigger RSCP THD[dBm]-90Inter-freq measure timer length[s]60Inter-freq coverage handover delay trig time0

&L&G&C&F&RSecurity Level:&L&D&CConfidential Information of Huawei. No Spreading without Permission&RPage&Pof&N

Inter_RATRGAZH01O&M #5737787%%LST INTERRATHOCOV:;%%RETCODE = 0 Execution succeeded.List RNC Oriented Coverage based Inter-rat Handover Measurement Algorithm Parameters------------------------------------------------------------------------------------Inter-RAT period report interval[ms]D5003A Measure QuantityInter-RAT hysteresis[0.5dB]0Time to trigger for non-verified GSM cell[ms]0Time to trigger for verified GSM cell[ms]03A hysteresis[0.5dB]3A event trigger delay time[ms]Inter-RAT filter coeffD3Inter-RAT CS measure start Ec/No THD[dB]-11CSInter-RAT CS measure stop Ec/No THD[dB]-8Inter-RAT CS measure start RSCP THD[dBm]-100Inter-RAT CS measure stop RSCP THD[dBm]-95Inter-RAT CS Used frequency trigger Ec/No THD[dB]Inter-RAT CS Used frequency trigger RSCP THD[dBm]Inter-RAT R99 PS measure start Ec/No THD[dB]-17R99Inter-RAT R99 PS measure stop Ec/No THD[dB]-14Inter-RAT R99 PS measure start RSCP THD[dBm]-115Inter-RAT R99 PS measure stop RSCP THD[dBm]-110Inter-RAT R99 PS Used frequency trigger Ec/No THD[dB]Inter-RAT R99 PS Used frequency trigger RSCP THD[dBm]Inter-RAT H measure start Ec/No THD[dB]-17HSPAInter-RAT H measure stop Ec/No THD[dB]-14Inter-RAT H measure start RSCP THD[dBm]-115Inter-RAT H measure stop RSCP THD[dBm]-110Inter-RAT H Used frequency trigger Ec/No THD[dB]Inter-RAT H Used frequency trigger RSCP THD[dBm]3A event retry max times3A event retry period[500ms]Inter-RAT report modePeriodical reporting2D2F filter coeffD3Weight for Used frequency02D hysteresis[0.5dB]02F hysteresis[0.5dB]02D event trigger delay time[ms]D3202F event trigger delay time[ms]D1280BSIC verify switchVerify modeInter-RAT CS handover decision THD[dBm]13-98dBmInter-RAT R99 PS handover decision THD[dBm]13-98dBmInter-RAT H handover decision THD[dBm]13-98dBmInter-RAT measure timer length[s]60Inter-RAT PingPong timer[s]0Inter-RAT PingPong Hyst[0.5dB]0Inter-RAT HO physical channel failure THD3Inter-Rat HO physical channel failure penalty timer[s]30fdd_qmin-8 ??

&L&G&C&F&RSecurity Level:&L&D&CConfidential Information of Huawei. No Spreading without Permission&RPage&Pof&N

State transitionCell Reselection Counter Threshold9---------------BE D2F/R Or F/R2P 4B Threshold[byte]D64Cell Reselection Timer[s]180BE D2F/R 4B Time[ms]D5000BE FACH to PCH Transition Timer[s]65535cell PCH disableBE D2F/R 4B Pending Time[ms]D1000BE DCH to FACH Transition Timer[s]5BE F2P 4B Time[ms]D5000BE HS-DSCH to FACH Transition Timer[s]5from low activity state in HS-DSCH to FACHBE F2P 4B Pending Time[ms]D1000Realtime DCH or HSPA To FACH Transition Timer[s]180BE F/R2D 4A Threshold[byte]D1024BE E-DCH To FACH State Transition Timer[s]5BE F/R2D 4A Time[ms]D0BE CPC to FACH Transition Timer[s]5BE HS-DSCH2F 4B Threshold[byte]D64Realtime CPC to FACH Transition Timer[s]180BE HS-DSCH2F 4B Time[ms]D5000goes to low activity stateBE DCH to E_FACH Transition Timer[s]5BE HS-DSCH2F 4B Pending Time[ms]D1000BE HSPA to E_FACH Transition Timer[s]5BE F2HS-DSCH 4A Threshold[byte]D1024Realtime DCH or HSPA to E_FACH Transition Timer[s]180BE F2HS-DSCH 4A Time[ms]D0BE CPC to E_FACH Transition Timer[s]5RT D/HSPA2F 4B Threshold[byte]D64Realtime CPC to E_FACH Transition Timer[s]180RT D/HSPA2F 4B Time[ms]D5000RT D/HSPA2F 4B Pending Time[ms]D16000RT F2D/HSPA 4A Threshold[byte]D1024List PS User Inactive Detecting TimerRT F2D/HSPA 4A Time[ms]D240-------------------------------------E-DCH Throu Meas Period[10ms]30Conversational service T120E-DCH2F 4B Threshold[kbit/s]8Conversational service T220E-DCH2F 4B Period Amount2Streaming service T120E-DCH2F 4B Pending Period Amount4Streaming service T220BE F2E-DCH 4A Threshold[byte]D1024Interactive service T120BE F2E-DCH 4A Time[ms]D0Interactive service T220BE F2CPC_HS-DSCH 4A Threshold[byte]D1024Background service T120When detecting that the Ps' Background User had no data to transfer for a long time which longer than this timer, the PDCP layer would request the RRC layer to release this Radio Access BearBE F2CPC_HS-DSCH 4A Time[ms]D0Background service T220RT F2CPC_HSPA 4A Threshold[byte]D1024IMS signal T120RT F2CPC_HSPA 4A Time[ms]D0IMS signal T220BE F2CPC_E-DCH 4A Threshold[byte]D1024BE FACH2CPC_E-DCH 4A Time[ms]D0BE E_FACH2D 4A Threshold[byte]D1024BE E_FACH2D 4A Time[ms]D0BE E_FACH2HS-DSCH 4A Threshold[byte]D1024BE E_FACH2HS-DSCH 4A Time[ms]D0RT E_FACH2D/HSPA 4A Threshold[byte]D1024RT E_FACH2D/HSPA 4A Time[ms]D0BE E_FACH2CPC 4A Threshold[byte]D1024BE E_FACH2CPC 4A Time[ms]D0RT E_FACH2CPC_HSPA 4A Threshold[byte]D1024RT E_FACH2CPC_HSPA 4A Time[ms]D0(Number of results1)

Sheet1ParameterMinMaxTypical settingsEasy / FastHard / SlowValue definitionInter-RAT measurement quantityCPICH_Ec/No,CPICH_RSCP,AutoAUTOCS2D Ec/No CS threshold-24db0db-14db-14db-15dbThe RNC sends the signaling to activate compressed mode and start inter-RAT measurement, if the UE reports the event 2D when the measured value is smaller than the value of this parameter.2D RSCP CS threshold-115dBm25dBm-100db-95db-100dbThe RNC sends the signaling to activate compressed mode and start inter-RAT measurement, if the UE reports the event 2D when the measured value is smaller than the value of this parameter.2F Ec/No CS threshold-24db0db-12db-12db-13dbThe RNC sends the signaling to activate compressed mode and stop inter-RAT measurement, if the UE reports the event 2F when the measured value is larger than the value of this parameter.2F RSCP CS threshold-115dBm25dBm-97db-92db-97dbThe RNC sends the signaling to activate compressed mode and stop inter-RAT measurement, if the UE reports the event 2F when the measured value is larger than the value of this parameter.CS HO UMTS threshold For RSCP-115dBm25dBm-97db-92db-97dbWhen the quality of the currently used UTRAN frequency is below this threshold and the [Inter-RAT handover decision THD] is reachedCS HO UMTS threshold For Ec/No-24db0db-12db-12db-13dbWhen the quality of the currently used UTRAN frequency is below this threshold and the [Inter-RAT handover decision THD] is reachedCS HO UMTS threshold For GSM0(-110dbm)63(-48dbm)16(-95dbm)21(-90dbm)16(-95dbm)Physical value range: -110~-48 (The value 1 corresponds to the physical value -110, 2 to -109, ..., 63 to -48.)the value 0 means the physical value is smaller than -110 dBm.PS R992D Ec/No R99 PS threshold-24db0db-15db-14db-15dbThe RNC sends the signaling to activate compressed mode and start inter-RAT measurement, if the UE reports the event 2D when the measured value is smaller than the value of this parameter.2D RSCP R99 PS threshold-115dBm25dBm-110db-105db-110dbThe RNC sends the signaling to activate compressed mode and start inter-RAT measurement, if the UE reports the event 2D when the measured value is smaller than the value of this parameter.2F Ec/No R99 PS threshold-24db0db-13db-12db-13dbThe RNC sends the signaling to activate compressed mode and stop inter-RAT measurement, if the UE reports the event 2F when the measured value is larger than the value of this parameter.2F RSCP R99 PS threshold-115dBm25dBm-107db-102db-107dbThe RNC sends the signaling to activate compressed mode and stop inter-RAT measurement, if the UE reports the event 2F when the measured value is larger than the value of this parameter.PS R99 UMTS HO threshold For RSCP-115dBm25dBm-107db-102db-107dbWhen the quality of the currently used UTRAN frequency is below this threshold and the [Inter-RAT handover decision THD] is reachedPS R99 UMTS HO threshold For Ec/No-24db0db-13db-12db-13dbWhen the quality of the currently used UTRAN frequency is below this threshold and the [Inter-RAT handover decision THD] is reachedPS R99 UMTS HO threshold For GSM0(-110dbm)63(-48dbm)16(-95dbm)21(-90dbm)16(-95dbm)Physical value range: -110~-48 (The value 1 corresponds to the physical value -110, 2 to -109, ..., 63 to -48.)the value 0 means the physical value is smaller than -110 dBm.HSPA2D Ec/No H threshold-24db0db-15db-14db-15dbThe RNC sends the signaling to activate compressed mode and start inter-RAT measurement, if the UE reports the event 2D when the measured value is smaller than the value of this parameter.2D RSCP H threshold-115dBm25dBm-110db-105db-110dbThe RNC sends the signaling to activate compressed mode and start inter-RAT measurement, if the UE reports the event 2D when the measured value is smaller than the value of this parameter.2F Ec/No H threshold-24db0db-13db-12db-13dbThe RNC sends the signaling to activate compressed mode and stop inter-RAT measurement, if the UE reports the event 2F when the measured value is larger than the value of this parameter.2F RSCP H threshold-115dBm25dBm-107db-102db-107dbThe RNC sends the signaling to activate compressed mode and stop inter-RAT measurement, if the UE reports the event 2F when the measured value is larger than the value of this parameter.H HO UMTS threshold For RSCP-115dBm25dBm-107db-102db-107dbWhen the quality of the currently used UTRAN frequency is below this threshold and the [Inter-RAT handover decision THD] is reachedH HO UMTS threshold For Ec/No-24db0db-13db-12db-13dbWhen the quality of the currently used UTRAN frequency is below this threshold and the [Inter-RAT handover decision THD] is reachedH HO UMTS threshold For GSM0(-110dbm)63(-48dbm)16(-95dbm)21(-90dbm)16(-95dbm)Physical value range: -110~-48 (The value 1 corresponds to the physical value -110, 2 to -109, ..., 63 to -48.)the value 0 means the physical value is smaller than -110 dBm.2D Hysteresis0(0db)29(14.5db)4(2db)2(1db)6(3db)The larger the value of this parameter, the less the ping-pong effect and the fewer the decision mistakes2D Trigger timeD0(0ms)D5000(5000ms)D320(320ms)D320(320ms)D640(640ms)alue range: D0, D10, D20, D40, D60, D80, D100, D120, D160, D200, D240, D320, D640, D1280, D2560, D5000 Physical value range: 0, 10, 20, 40, 60, 80, 100, 120, 160, 200, 240, 320, 640, 1280, 2560, 5000( ms)2F Hysteresis0(0db)29(14.5db)4(2db)2(1db)6(3db)The larger the value of this parameter, the less the ping-pong effect and the fewer the decision mistakes2F Trigger timeD0(0ms)D5000(5000ms)D1280(1280ms)D640(640ms)D1280(1280ms)alue range: D0, D10, D20, D40, D60, D80, D100, D120, D160, D200, D240, D320, D640, D1280, D2560, D5000 Physical value range: 0, 10, 20, 40, 60, 80, 100, 120, 160, 200, 240, 320, 640, 1280, 2560, 5000( ms)HO Hysteresis0(0db)15(7.5db)0(0db)0(0db)2(1db)This parameter decides whether to trigger inter-RAT handovers.HO Trigger timeD0(0ms)D5000(5000ms)D0(0ms)D0(0ms)D10(10ms)alue range: D0, D10, D20, D40, D60, D80, D100, D120, D160, D200, D240, D320, D640, D1280, D2560, D5000 Physical value range: 0, 10, 20, 40, 60, 80, 100, 120, 160, 200, 240, 320, 640, 1280, 2560, 5000( ms)CellreseleltionSsearch RAT-32202(-14db)3(-14db)2(-14db)A threshold for inter-RAT cell reselection. When the quality (CPICH Ec/No measured by UE) of the serving cell is lower than this threshold plus the [Qqualmin] of the cell, the inter-RAT cell reselection procedure will be startedTreselections0311(s)0(s)2(s)Trigger time for inter RAT cell reseletionQqualmin-240-18(db)The minimum required quality threshold corresponding to CPICH Ec/No. The UE can camp on the cell only when the measured CPICH Ec/No is greater than the value of this parameter. The higher the parameter value is, the more difficult it is for the UE to reside in the cell. The lower parameter value is, the easier it is for the UE to reside in the cell, but it is possible that the UE cannot receive the system messages that are sent through the PCCPCH. For detailed information, refer to the 3GPP TS 25.304.Qrxlevmin-58-13-58Value range: -58~-13 Physical value range: -115~-25; step: 2 (-58:-115; -57:-113; ...; -13:-25 ) Physical unit: dBm Content: The minimum required RX threshold corresponding to CPICH RSCP. The UE can camp on the cell only when the measured CPICH RSCP is greater than the value of this parameter. The setting of Qrxlevmin should be related to Qqualmin. The higher the parameter is, the more difficult it is for the UE to reside in the cell. The lower parameter is, the easier it is for the UE to reside in the cell, but it is possible that the UE cannot receive the system messages that are sent through the PCCPCH. For detailed information, refer to 3GPP TS 25.304. Recommended value: -58Maxallowedultxpower-503324(db)Value range: -50~33 Physical unit: dBm Content: The maximum allowed uplink transmit power of a UE in the cell, which is related to the network planning. For detailed information, refer to 3GPP TS 25.304. Recommended value: 24Idleqhyst1s0202Value range: 0~20 Physical value range: 0~40; step: 2 Physical unit: dB Content: The hysteresis value of the serving FDD cells in idle mode in case the quality measurement for cell selection and reselection is set to CPICH RSCP. It is related to the slow fading feature of the area where the cell is located. The greater the slow fading variance is, the greater this parameter. According to the R regulation, the current serving cell involves in cell selection after the measurement value is added with the hysteresis value. The measurement hysteresis aims to prevent the ping-pong effect of the cell reselection, which is caused by the slow fading when the UE is on the edge of the cell. The ping-pong effect may trigger frequent location updates (idle mode), URA updates (URA_PCH), or cell updates (CELL_FACH, CELL_PCH), and thus increase the load of network signaling and the consumption of UE batteries. Set a proper measurement hysteresis to reduce as much as possible effect of the slow fading as well as ensuring timely cell updates of the UE. According to the CPICH RSCP emulation report of inter-frequency hard handovers, the measurement hysteresis ranges 4 dBm to 5 dBm and is set to 4 dBm by default when the slow fading variance is 8 dB and the relative distance is 20 m. In the cells where the slow fading variance is low and the average moving speed of UEs is high, for example the suburbs and countryside, reduce the measurement hysteresis to guarantee timely location updates of UEs. The higher the measurement hysteresis is, the less likely it is for various types of cell reselections to occur, and the better the slow fading resistance capability is, but the slower the system reacts to the environment changes. For detailed information of this parameter, refer to 3GPP TS 25.304. Recommended value: 2Idleqhyst2s0202Value range: {{0~20},{255}} Physical value range: 0~40; step: 2 Physical unit: dB. Content: The hysteresis value of the serving FDD cells in idle mode in case the quality measurement for cell selection and reselection is set to CPICH Ec/No. It is related to the slow fading feature of the area where the cell is located. The greater the slow fading variance is, the greater this parameter. It is optional. If it is not configured, [Hysteresis 1] will be adopted as the value. This parameter is not configured when its value is 255. According to the R regulation, the current serving cell involves in cell selection after the measurement value is added with the hysteresis value. The measurement hysteresis aims to prevent the ping-pong effect of the cell reselection, which is caused by the slow fading when the UE is on the edge of the cell. The ping-pong effect may trigger frequent location updates (idle mode), URA updates (URA_PCH), or cell updates (CELL_FACH, CELL_PCH), and thus increase the load of network signaling and the consumption of UE batteries. Set a proper measurement hysteresis to reduce as much as possible effect of the slow fading as well as ensuring timely cell updates of the UE. According to the CPICH RSCP emulation report of inter-frequency hard handovers, the measurement hysteresis ranges 4 dBm to 5 dBm and is set to 4 dBm by default when the slow fading variance is 8 dB and the relative distance is 20 m. In the cells where the slow fading variance is low and the average moving speed of UEs is high, for example the suburbs and countryside, reduce the measurement hysteresis to guarantee timely location updates of UEs. The higher the measurement hysteresis is, the less likely it is for various types of cell reselections to occur, and the better the slow fading resistance capability is, but the slower the system reacts to the environment changes. For detailed information of this parameter, refer to 3GPP TS 25.304. Recommended value: the same as Qhyst1s for idle modeidleqoffset1sn-50500(db)Offset of cell CPICH RSCP measurement value in cell selection or reselection when the UE is in idle mode Value range: -50~50 Content: Physical unit: dB Offset of neighboring cell CPICH measurement value This parameter is used for RSSI measurement. The offset is subtracted from the neighboring cell measurement value before cell reselection. In cell reselection algorithm, this parameter is used for moving the border of a cell. This parameter can be configured by the network planner according to reality. NOTE: In FDD mode, this parameter is valid only when SIB11 Indicator is set as TRUE. For details, refer to 3GPP TS 25.331. As for the impact on network performance: The larger the value of the parameter, the lower the probability of selecting neighboring cells. The smaller the value of the parameter, the higher the probability of doing so. Recommended value (default value): 0idleqoffset2sn-50500(db)Offset of cell CPICH Ec/No measurement value in cell selection or reselection when the UE is in idle mode Value range: -50~50 Content: Physical unit: dB Offset of neighboring cell CPICH measurement value This parameter is used for Ec/No measurement. The offset is subtracted from the neighboring cell measurement value before cell reselection. In cell reselection algorithm, this parameter is used for moving the border of a cell. This parameter can be configured by the network planner according to reality. NOTE: In FDD mode, this parameter is valid only when SIB11 Indicator is set as TRUE. For details, refer to 3GPP TS 25.331. As for the impact on network performance: The larger the value of the parameter, the lower the probability of selecting neighboring cells. The smaller the value the parameter, the higher the probability of doing so. Recommended value (default value): 0fdd_qoffset0150:Always8(0 dB)9(+4dB)0:Always if acceptable1:-28dB 2:-24dB 3:-20dB 4:-16dB15:28dBfdd_qmin073(-8dB)5(-10dB)3(-8dB)0:-20dB, 1:-6dB, 2:-18, 3:-8dB, 4:-16dB, 5:-10dB, 6:-14dB, 7:-12dBqsearch_i0157 (Always Search)search below 0 : -98dBm/ 1: -94 /2: -90/ 5:-78/ 6: -74 / 7: Alwaysqsearch_c01515 (never)search below 0 : -98dBm/ 1: -94 /2: -90/ 5:-78/ 6: -74 / 7: Alwaysqsearch_p0157 (Always Search)

&L&G&C&F&RSecurity Level:&L&D&CHUAWEI Confidential&RPage&Pof&N

Cell Selection And ReselectionList Cell Selection And Reselection Information-----------------------------------------------Hysteresis 2 for idle mode[2dB]1Hysteresis 2 for connect mode[2dB]1Non-HCS indicatorNOT_CONFIGUREDNon-HCS max TCR[s]Non-HCS NCRNon-HCS TCR max hysteresis[s]Delta Min Rx levelCell Sel-reselection quality measureCPICH Ec/N0Hysteresis 1 for idle mode[2dB]2Hysteresis 1 for connect mode[2dB]2Reselection delay time[s]1Min quality level[dB]-18S -CriteriaMin Rx level[2dBm]-58Min Rx level Extend SupportFALSEMax allowed UE UL TX power[dBm]24Intra-freq cell reselection threshold for idle mode[2dB]510dB-8Inter-freq cell reselection threshold for idle mode[2dB]48dB-105Intra-freq cell reselection threshold for connect mode[2dB]510dB-8Inter-freq cell reselection threshold for connect mode[2dB]48dB-105Inter-RAT cell reselection threshold[2dB]24dB-14Speed dependent scaling factor for reselection delay255Inter-freqency scaling factor for reselection delay255Inter-RAT scaling factor for reselection delay255Hysteresis 1 for UE in CELL_PCH or URA_PCH state[dB]255Hysteresis 1for UE in CELL_FACH state[dB]255Hysteresis 2 for UE in CELL_PCH or URA_PCH state[dB]255Hysteresis 2 for UE in CELL_FACH state[dB]255Reselection delay time for UE in PCH state[s]255Reselection delay time for UE in CELL_FACH state[0.2s]255

2G Cell ReselectionSet Call Control UTRAN System Message Parameters of Cell(SET GCELLCCUTRANSYS)Parameter IDParameter NameParameter DescriptionIDTYPEIndex TypeMeaning: Type of an indexGUI Value Range: BYNAME(By Name), BYID(By Index)Actual Value Range: BYNAME, BYIDUnit: NoneDefault Value: NoneRecommended Value: NoneCELLIDCell IndexMeaning: Index of a cell, uniquely identifying a cell in a BSCGUI Value Range: 0~2047Actual Value Range: 0~2047Unit: NoneDefault Value: NoneRecommended Value: NoneCELLNAMECell NameMeaning: Name of a cell, uniquely identifying a cell in a BSCGUI Value Range: NoneActual Value Range: 1~64 charactersUnit: NoneDefault Value: NoneRecommended Value: NoneMSCVERMSC Version IndicationMeaning: Protocol version of the MSC that is connected to the BSC. The supported signaling varies with the protocol versions.GUI Value Range: R98_or_below(R98 or below), R99_or_above(R99 or above)Actual Value Range: R98_or_below, R99_or_aboveUnit: NoneDefault Value: NoneRecommended Value: R98_or_belowMEASURETYPEMeasurement Report TypeMeaning: Type of the measurement report (MR) reported by the MSGUI Value Range: EnhMeasReport(Enhanced Measurement Report), ComMeasReport(Common Measurement Report)Actual Value Range: EnhMeasReport, ComMeasReportUnit: NoneDefault Value: NoneRecommended Value: ComMeasReportGSMFREQCNUMServing Band ReportingMeaning: Number of neighboring cells that meet the following conditions: If "MBR" is indicated in a system message, the MS reports the number of neighboring cells at each frequency band. If the MS reports the number of neighboring cells at the same frequency band of the serving cell, it can report a maximum of the value of this parameter.These neighboring cells must meet the following requirements:1. The receive levels of the neighboring cells must be higher than 900 Reporting Threshold or 1800 Reporting Threshold.2. The BSIC of a neighboring cell must be valid.3. The signals of the neighboring cells must be the strongest among all the neighboring cells at the same frequency band.GUI Value Range: 0~3Actual Value Range: 0~3Unit: NoneDefault Value: NoneRecommended Value: 3QIQsearch IMeaning: This parameter specifies the level threshold for cell reselection in idle mode. In idle mode, if the signal level of the serving cell is below [0, 7] or above [8, 15], the MS starts to search for 3G cells. For example, if this parameter is set to 5 and if the signal level of the serving cell is lower than 5, the MS starts to search for 3G cells; if this parameter is set to 10 and if the signal level of the serving cell is above 10, then the MS starts to search for 3G cells. The values of this parameter correspond to the following decibel values: 0: -98 dBm1: -94 dBm 2: -90 dBm3: -86 dBm 4: -82 dBm5: -78 dBm 6: -74 dBm 7: (always), that is, the MS keeps searching for 3G cells 8: -78 dBm9: -74 dBm 10: -70 dBm 11: -66 dBm 12: -62 dBm 13: -58 dBm 14: -54 dBm 15: Positive infinity(never), that is, the MS does not search for 3G cellsGUI Value Range: 0~15Actual Value Range: -98, -94, -90, -86, -82, -78, -74, (always), -78, -74, -70, -66, -62, -58, -54, Positive infinity(never)Unit: NoneDefault Value: NoneRecommended Value: 15QCIQsearch C InitialMeaning: This parameter specifies the threshold of the signal level for cell reselection in connection mode before "Qsearch C" is obtained.GUI Value Range: Use_Qsearch_I(Use Qsearch_I), Always(Always)Actual Value Range: Use_Qsearch_I, AlwaysUnit: NoneDefault Value: NoneRecommended Value: Use_Qsearch_IFDDQOFFFDD Q OffsetMeaning: This parameter specifies one of the thresholds of the signal level for 3G cell reselection.A FDD cell becomes a candidate cell if all the following conditions are met for five consecutive seconds:1.Receive level of the FDD cell > Average receive level of the current serving cell + FDD Q offset;The FDD cell meets the following condition in the case of any neighboring 2G cell: Receive level of the FDD cell > Receive level of any neighboring 2G cell + FDD Q offset;2. Ec/No of the FDD cell > FDD Qmin - FDD Qmin Offset;3. Receive level of the FDD cell > "RSCP Threshold";If multiple FDD cells meet the preceding conditions, the MS reselects the cell with the strongest receive level.See 3GPP TSs 45.008 and 25.304.The values of this parameter correspond to the following decibel values:0: - (always select a cell if acceptable)1: -28 dB,2: -24 dB,...15: 28 dB.GUI Value Range: 0~15Actual Value Range: Negative infinity, -28~28, step: 4Unit: dBDefault Value: NoneRecommended Value: 8FDDRSCPMINFDD RSCP Min.Meaning: Minimum level threshold of UTRAN cell reselection. During the cell reselection decision from a GSM cell to a FDD cell, this parameter is used to calculate the RSCP threshold of the target cell. A FDD cell becomes a candidate cell if all the following conditions are met for five consecutive seconds:1.Receive level of the FDD cell > Average receive level of the current serving cell + FDD Q offset;The FDD cell meets the following condition in the case of any neighboring 2G cell: Receive level of the FDD cell > Receive level of any neighboring 2G cell + FDD Q offset;2. Ec/No of the FDD cell > FDD Qmin - FDD Qmin Offset;3. Receive level of the FDD cell > "RSCP Threshold";If multiple FDD cells meet the preceding conditions, the MS reselects the cell with the strongest receive level.See 3GPP TSs 45.008 and 25.304.The values of this parameter correspond to the following decibel values:0 = -114 dBm,1 = -112 dBm,2 = -110 dBm,...14 = -86 dBm,15 = -84 dBm.GUI Value Range: 0~15Actual Value Range: -114~-84, step: 2Unit: dBmDefault Value: NoneRecommended Value: 6FDDREPFDD REP QUANTMeaning: This parameter specifies whether Ec/No or RSCP is used for the measurement report on a FDD cell. Ec/No stands for the signal-to-noise ratio. RSCP stands for the received signal code power.GUI Value Range: RSCP(RSCP), EcN0(Ec/N0)Actual Value Range: RSCP, EcN0Unit: NoneDefault Value: NoneRecommended Value: RSCPFDDFREQCNUMFDD Multirate ReportingMeaning: Number of UTRAN FDD cells that should be included in measurement reportGUI Value Range: 0~3Actual Value Range: 0~3Unit: NoneDefault Value: NoneRecommended Value: 2FDDQMINFDD QminMeaning: This parameter specifies one of the parameters for FDD cell reselection.A FDD cell becomes a candidate cell if all the following conditions are met for five consecutive seconds:1.Receive level of the FDD cell > Average receive level of the current serving cell + FDD Q offset;The FDD cell meets the following condition in the case of any neighboring 2G cell: Receive level of the FDD cell > Receive level of any neighboring 2G cell + FDD Q offset;2. Ec/No of the FDD cell > FDD Qmin - FDD Qmin Offset;3. Receive level of the FDD cell > "RSCP Threshold";If multiple FDD cells meet the preceding conditions, the MS reselects the cell with the strongest receive level.See 3GPP TSs 45.008 and 25.304.The values of this parameter correspond to the following decibel values:0: -20 dB,1: -6 dB,2: -18 dB,3: -8 dB,4: -16 dB,5: -10 dB,6: -14 dB,7: -12 dB.GUI Value Range: 0~7Actual Value Range: -20, -6, -18, -8, -16, -10, -14, -12Unit: dBDefault Value: NoneRecommended Value: 0FDDQMINOFFSETFDD Qmin OffsetMeaning: Offset of the minimum threshold for Ec/No during a FDD cell reselection.A FDD cell becomes a candidate cell if all the following conditions are met for five consecutive seconds:1.Receive level of the FDD cell > Average receive level of the current serving cell + FDD Q offset;The FDD cell meets the following condition in the case of any neighboring 2G cell: Receive level of the FDD cell > Receive level of any neighboring 2G cell + FDD Q offset;2. Ec/No of the FDD cell > FDD Qmin - FDD Qmin Offset;3. Receive level of the FDD cell > "RSCP Threshold";If multiple FDD cells meet the preceding conditions, the MS reselects the cell with the strongest receive level.See 3GPP TSs 45.008 and 25.304.GUI Value Range: 0~7Actual Value Range: 0~7Unit: dBDefault Value: NoneRecommended Value: 0QPQsearch PMeaning: This parameter specifies one threshold of the signal level for cell reselection in packet transfer mode. In packet transfer mode, if the signal level of the serving cell is below [0, 7] or above [8, 15], the MS starts to search for 3G cells. For example, if this parameter is set to 5 and if the signal level of the serving cell is lower than 5, the MS starts to search for 3G cells; if this parameter is set to 10 and if the signal level of the serving cell is above 10, then the MS starts to search for 3G cells. The values of this parameter correspond to the following decibel values: 0: -98 dBm 1: -94 dBm ... 6: -74 dBm 7: (always) 8: -78 dBm 9: -74 dBm ... 14: -54 dBmGUI Value Range: 0~15Actual Value Range: -98, -94, -90, -86, -82, -78, -74, (always), -78, -74, -70, -66, -62, -58, -54, Positive infinity(never)Unit: NoneDefault Value: NoneRecommended Value: 15SEARCH3G3G Search PRIOMeaning: Whether to allow the MS to search for a 3G cell when the BSIC must be decodedGUI Value Range: NO(No), YES(Yes)Actual Value Range: NO, YESUnit: NoneDefault Value: NoneRecommended Value: YESINVALBSICENInvalid BSIC ReportingMeaning: Whether a measurement report can contain the information about a cell with an invalid BSIC. The cell with an invalid BSIC is an unconfigured neighboring cell.GUI Value Range: NO(No), YES(Yes)Actual Value Range: NO, YESUnit: NoneDefault Value: NoneRecommended Value: NOSCALEORDERSCALE_ORDERMeaning: This parameter indicates that when the MS reports the EMR, it adds the value of this parameter to the received signal level, and then converts the result into the RXLEV value. For details, see GSM Rec. 05.08.If the SCALE_Order reported by the MS is 10 dBm, level values 0-63 map with -100 dBm to -37 dBm.If the SCALE_Order reported by the MS is 0 dBm, level values 0-63 map with -110 dBm to -47 dBm.If the SCALE_Order reported by the MS is Automatic, the MS chooses the least SCALE while ensuring that the MS can report the most strong level.GUI Value Range: ADD0dB(+0dB), ADD10dB(+10dB), Automatic(Automatic)Actual Value Range: ADD0dB, ADD10dB, AutomaticUnit: NoneDefault Value: NoneRecommended Value: ADD0dBQSEARCHCQsearch CMeaning: In connection mode, if the signal level is below [0-7] or above [8-15], the MS starts to search for 3G cells. For example, if this parameter is set to 5 and if the signal level of the serving cell is lower than 5, the MS starts to search for 3G cells; if this parameter is set to 10 and if the signal level of the serving cell is above 10, then the MS starts to search for 3G cells. 0: -98 dBm1: -94 dBm...6: -74 dBm7: (always)8: -78 dBm9: -74 dBm...14: -54 dBm15: Positive infinity (never)GUI Value Range: 0~15Actual Value Range: -98, -94, -90, -86, -82, -78, -74, (always), -78, -74, -70, -66, -62, -58, -54, Positive infinity(never)Unit: NoneDefault Value: NoneRecommended Value: 15CELL900OFF900 Reporting OffsetMeaning: Offset applied to the receive level of a GSM900 cell in the measurement report before prioritizing cells by frequency bands. Before cells are sequenced by priority, according to frequencies, the value of this parameter must be added to the receive level value in the measurement report of the cells at the 900 MHz frequency.The values of this parameter correspond to the following decibel values:0: 0 dB1: 6 dB...7: 42 dBGUI Value Range: 0~7Actual Value Range: 0~42, step: 6Unit: dBDefault Value: NoneRecommended Value: 0CELL900THRED900 Reporting ThresholdMeaning: Threshold of the measurement report of the cells at the 900 MHz frequency. The measurement report is valid only when the receive level in the measurement report of the GSM900 cell exceeds this threshold. After being filtered, the measurement report is used for prioritizing the cells. The value 7 means infinite:0: 0 dB1: 6 dB...6: 36 dB7: positive infinityGUI Value Range: 0~7Actual Value Range: 0~36, Positive infinity, step: 6Unit: dBDefault Value: NoneRecommended Value: 0CELL1800OFF1800 Reporting OffsetMeaning: Offset of the measurement report of the cells at the 1800 MHz frequency. Before cells are sequenced by priority, according to frequencies, the value of this parameter must be added to the receive level value in the measurement report of the cells at the 1800 MHz frequency.The values of this parameter correspond to the following decibel values:0: 0 dB1: 6 dB...7: 42 dBGUI Value Range: 0~7Actual Value Range: 0~42, step: 6Unit: dBDefault Value: NoneRecommended Value: 0CELL1800THRED1800 Reporting ThresholdMeaning: Threshold of the measurement report of the cells at the 1800 MHz frequency. When the receive level value in the measurement report of the cells at the 1800 MHz frequency exceeds the value of this parameter, the report takes effect. After being filtered, the measurement report is used for priority sequencing of cells.The values of this parameter correspond to the following decibel values:0: 0 dB1: 6 dB...6: 36 dB7: positive infinityGUI Value Range: 0~7Actual Value Range: 0~36, Positive infinity, step: 6Unit: dBDefault Value: NoneRecommended Value: 0FDDCELLOFFFDD Reporting OffsetMeaning: Offset of a FDD cell report.When the priority of a 3G cell is sequenced, the value of this parameter be added to the receive level of the 3G cell in the measurement report.The values of this parameter correspond to the following decibel values:0: 0 dB1: 6 dB...7: 42 dBGUI Value Range: 0~7Actual Value Range: 0~42, step: 6Unit: dBDefault Value: NoneRecommended Value: 0FDDCELLTHREDFDD Reporting ThresholdMeaning: Threshold of a FDD cell report.When the receive level value in the measurement report of a 3G cell exceeds the value of this parameter, the measurement report takes effect. After the valid measurement report is filtered, the 3G cell joins the cell priority sequence.The values of this parameter correspond to the following decibel values:0: 0 dB1: 6 dB...6: 36 dB7: positive infinityGUI Value Range: 0~7Actual Value Range: 0~36, Positive infinity, step: 6Unit: dBDefault Value: NoneRecommended Value: 0TDDCELLRESELDIVTDD Cell Reselect DiversityMeaning: A TDD cell can become a candidate cell only when the average receive level of the TDD cell is greater than the TDD Cell Reselect Diversity of the serving cell.The value of this parameter corresponds to the following decibel value:0: negative infinity1: -28 dB2: -24 dB...15: 28 dBGUI Value Range: 0~15Actual Value Range: Negative infinity, -28~28, step: 4Unit: dBDefault Value: NoneRecommended Value: 8BESTTDDCELLNUMBest TDD Cell NumberMeaning: Number of UTRAN TDD cells that should be included in measurement reportGUI Value Range: 0~3Actual Value Range: 0~3Unit: NoneDefault Value: NoneRecommended Value: 1TDDCELLOFFTDD Reporting OffsetMeaning: When the priority of a TDD cell is ranked, the value of this parameter is added to the receive level of the TDD cell in the measurement report.The values of this parameter correspond to the following decibel values:0: 0 dB1: 6 dB...7: 42 dBGUI Value Range: 0~7Actual Value Range: 0~42, step: 6Unit: dBDefault Value: NoneRecommended Value: 0TDDCELLTHREDTDD Reporting ThresholdMeaning: Threshold for determining whether the MR about a TDD cell is valid.The measurement report is valid if the receive level of the TDD cell in the measurement report is greater than the value of this parameter. After the valid measurement report is filtered, the TDD cell joins in the cell prioritization.The value of this parameter corresponds to the following decibel value:0: 0 dB1: 6 dB...6: 36 dB7: positive infinityGUI Value Range: 0~7Actual Value Range: 0~36, Positive infinity, step: 6Unit: dBDefault Value: NoneRecommended Value: 0TDDSIOPTIMIZEDALLOWEDTDD System Information Optimized AllowedMeaning: This parameter specifies whether to optimize the system information 2Quater and MI of the TDD neighboring cell. That is, to add an FDD neighboring cell information before the TDD neighboring cell information to solve the compatibility problem of some dual-mode MSs.GUI Value Range: NO(No), YES(Yes)Actual Value Range: NO, YESUnit: NoneDefault Value: NoneRecommended Value: NOTDDMIPROHIBITTDD MI System INFO Broadcasting ProhibitMeaning: This parameter specifies whether to send the system information MI which contains the 3G neighboring cell information in the TDD neighboring cell. The value YES(YES) indicates that the MI is sent, and the value NO(NO) indicates that the MI is not sent.GUI Value Range: NO(No), YES(Yes)Actual Value Range: NO, YESUnit: NoneDefault Value: NoneRecommended Value: NOTDDMIOPTIMIZEDALLOWEDTDD MI System Information OptimizedMeaning: This parameter specifies whether the TDD MI system information optimized function is enabled. When this parameter is set to NO and TDD System Information Optimized Allowed is set to YES, the MI system information issued in the TDD scenario does not carry neighboring cell scrambling codes. In other scenarios, the MI system information carries neighboring cell scrambling codes.GUI Value Range: NO(No), YES(Yes)Actual Value Range: NO, YESUnit: NoneDefault Value: NoneRecommended Value: NOPOS2QUATER2Quater Message Transmission ChannelMeaning: Whether to transmit the 2Quater message on the BCCH Norm channel or the BCCH Ext channelGUI Value Range: BCCHNorm(BCCHNorm), BCCHExt(BCCHExt)Actual Value Range: BCCHNorm, BCCHExtUnit: NoneDefault Value: NoneRecommended Value: BCCHNorm

GEXT3GCELLAdd 3G External Cell(ADD GEXT3GCELL)Parameter IDParameter NameParameter DescriptionEXT3GCELLIDCell IndexMeaning: ID of the cell. The cell ID cannot conflict with other cell IDs in the BSC. The cells in the BSC are numbered sequentially.GUI Value Range: 5048~8047Actual Value Range: 5048~8047Unit: NoneDefault Value: NoneRecommended Value: NoneEXT3GCELLNAMECell NameMeaning: Name of the cellGUI Value Range: NoneActual Value Range: 1~64 charactersUnit: NoneDefault Value: NoneRecommended Value: NoneMCCMCCMeaning: Mobile country code. This parameter identifies the country where a mobile subscriber is located, for example, the Chinese MCC is 460.GUI Value Range: NoneActual Value Range: 3 digitUnit: NoneDefault Value: NoneRecommended Value: NoneMNCMNCMeaning: Mobile network code. This parameter identifies the public land mobile network (PLMN) to which a mobile subscriber belongs.GUI Value Range: NoneActual Value Range: 2~3 digitUnit: NoneDefault Value: NoneRecommended Value: NoneLACCell LACMeaning: Location area code (LAC). MSs can freely move in the local location area with no need of location update. Reasonable local allocation can effectively lighten the signaling load and improve the call completion rate.Can be input in hexadecimal format. The hexadecimal format is H'****, for example, H'1214.GUI Value Range: 1~65533, 65535Actual Value Range: 1~65533, 65535Unit: NoneDefault Value: NoneRecommended Value: NoneCICell CIMeaning: Identity code of a cell, A cell is a wireless coverage area identified by a base station identity code and a global cell identification.Can be input in hexadecimal format. The hexadecimal format is H'****, for example, H'1214.GUI Value Range: 0~65535Actual Value Range: 0~65535Unit: NoneDefault Value: NoneRecommended Value: NoneRNCIDRNC IDMeaning: RNC ID of a 3G external cell. The value of this parameter must be consistent with the data configuration at the RNC.GUI Value Range: 0~4095Actual Value Range: 0~4095Unit: NoneDefault Value: NoneRecommended Value: NoneRNCINDEXNeighboring RNC IndexMeaning: Internal index of a neighboring RNC. This parameter is set to 255 when the neighboring RNC that serves the 3G external neighbor is not configured. You can use the LST GNRNC command to check whether the neighboring RNC is configured.GUI Value Range: 0~16, 255Actual Value Range: 0~16, 255Unit: NoneDefault Value: 255Recommended Value: 255CELLLAYERLayer of the cellMeaning: Layer of the cell. If the layer of the cell is lower, it is more likely that a handover to the cell will be triggered.GUI Value Range: 1, 2, 3, 4Actual Value Range: 1, 2, 3, 4Unit: NoneDefault Value: 3Recommended Value: 3DFDL UARFCNMeaning: Downlink frequency of the external 3G cellGUI Value Range: 0~16383Actual Value Range: 0~16383Unit: NoneDefault Value: NoneRecommended Value: NoneSCRAMBLEScrambling Code or Cell Parameter IdMeaning: Scrambling code of a 3G cell. The scrambling code is used to differentiate terminals or cells. It is used after spread spectrum. Therefore, it does not change the bandwidth of signals, but only distinguishes the signals from different sources. Through scrambling, multiple transceivers can use the same codes for spread spectrum. Scrambling is used to distinguish terminals on the uplink and to distinguish cells on the downlink.GUI Value Range: 0~511Actual Value Range: 0~511Unit: NoneDefault Value: NoneRecommended Value: 0DIVERSITYDiversityMeaning: Whether to activate transmit diversity on the common channel of a 3G cellGUI Value Range: NO(No), YES(Yes)Actual Value Range: NO, YESUnit: NoneDefault Value: NoneRecommended Value: NoneUTRANCELLTYPEUtran Cell TypeMeaning: This parameter specifies the type of a 3G cell. A cell type can be Frequency Division Duplex (FDD) or Time Division Duplex (TDD).GUI Value Range: FDD(FDD), TDD(TDD)Actual Value Range: FDD, TDDUnit: NoneDefault Value: NoneRecommended Value: NoneSYNCCASESync caseMeaning: Synchronization status. This parameter is used to identify different 3G cells. This parameter should be same with the configuration of 3G cells.GUI Value Range: SyncCase1(Sync case 1), SyncCase2(Sync case 2)Actual Value Range: SyncCase1, SyncCase2Unit: NoneDefault Value: NoneRecommended Value: NoneECNOTHRESEc/No Threshold for Layer Of 3G CellMeaning: Threshold for determining the layer of the 3G neighbor cell. If the Ec/No of the 3G neighbor cell is less than this threshold, the neighbor cell is set to the lowest layer (layer 5).GUI Value Range: 0~49Actual Value Range: 0~49Unit: dBDefault Value: 30Recommended Value: 30MINECNOTHRESMin Ec/No thresholdMeaning: Selects 3G candidate cells. If the measured value of a 3G neighboring cell is lower than this threshold, the 3G neighboring cell will be removed from among the 3G candidate cells.GUI Value Range: 0~49Actual Value Range: 0~49Unit: dBDefault Value: 10Recommended Value: 10FDDECQUALTHRSHPS FDD Ec/No Quality ThresholdMeaning: Minimum Ec/No of the 3G FDD cell candidateGUI Value Range: 0~49Actual Value Range: 0~49Unit: dBDefault Value: 10Recommended Value: 10FDDRSCPQUALTHRSHPS FDD RSCP Quality ThresholdMeaning: Minimum RSCP of the 3G FDD cell candidateGUI Value Range: 0~63Actual Value Range: 0~63Unit: NoneDefault Value: 10Recommended Value: 10TDDRSCPQUALTHRSHPS TDD RSCP Quality ThresholdMeaning: Minimum RSCP quality threshold that the TDD 3G candidate cell must reachGUI Value Range: 0~63Actual Value Range: 0~63Unit: NoneDefault Value: 10Recommended Value: 10RSCPTHRESRSCP Threshold for Layer of 3G CellMeaning: This parameter determines the layers of 3G neighboring cells. If the measured value of a 3G neighboring cell is lower than this threshold, the 3G neighboring cell is positioned at the bottom layer, that is, layer 4.GUI Value Range: 0~63Actual Value Range: 0~63Unit: dBDefault Value: 30Recommended Value: 30MINRSCPTHRESMin RSCP thresholdMeaning: Selects 3G candidate cells. If the measured value of a 3G neighboring cell is lower than this threshold, the 3G neighboring cell will be removed from among the 3G candidate cells.GUI Value Range: 0~63Actual Value Range: 0~63Unit: dBDefault Value: 10Recommended Value: 10LoadHoEnExt3GLoad Handover SupportMeaning: Indicates that if a 3G neighboring cell supports load handovers, the BSC adds the load information of the local cells in the signaling procedures related to this neighboring cell.GUI Value Range: NO(No), YES(Yes)Actual Value Range: NO, YESUnit: NoneDefault Value: NORecommended Value: NOLoadAccThresLoad handover Load Accept ThresholdMeaning: If the load of a cell is lower than the value of this parameter, the cell can admit the users handed over from other cells with higher load. Otherwise, the cell rejects such users.GUI Value Range: 0~100Actual Value Range: 0~100Unit: per centDefault Value: 80Recommended Value: 80OPNAMEOperator NameMeaning: Name of the operator. This parameter uniquely identifies an operatorGUI Value Range: NoneActual Value Range: 0~255 charactersUnit: NoneDefault Value: NoneRecommended Value: NoneRARoute AreaMeaning: The NS performs location management based on routing areas during GPRS packet services. Each routing area has a routing area identifier.GUI Value Range: 0~255Actual Value Range: 0~255Unit: NoneDefault Value: 0Recommended Value: 0

Meaning: Internal index of a neighboring RNC. This parameter is set to 255 when the neighboring RNC that serves the 3G external neighbor is not configured. You can use the LST GNRNC command to check whether the neighboring RNC is configured.

TimersSet Calling Process State Protection Timers(SET STATETIMER)NoteThe retransmit mechanism will be used if the signaling is sent by adopting RLC UM on Uu interface during channel handover.In this case, the setting of the corresponding waiting response timer for UE does not work.(For example, when the channel change from DCH to FACH or the channel change from FACH to DCH, the timer does not work.)The retransmit timer is 2 seconds. The RB reconfiguration message may retransmit three times when the timer expires.ParameterIDNameDescriptionNetworkRrcUeRspTmrRRC UE response timerDescription:A timer used to wait for RRC connection setup complete message from UE in RRC procedure.5000GUI value range:1~10000Actual value range:1~10000Unit:msDefault value:-Recommended Value:5000RrcIuRelCmdTmrRRC Iu release command timerDescription:A timer used to wait for the Iu release command message in RRC procedure.5000GUI value range:1~10000Actual value range:1~10000Unit:msDefault value:-Recommended Value:5000RrcRelRetranTmrRRC release retransmission timerDescription:A timer used to retransmit the RRC CONNECTION RELEASE message to UE.350GUI value range:1~5000Actual value range:1~5000Unit:msDefault value:-Recommended Value:350RrcPaingType1TmrRRC paging type 1 response timerDescription:A timer used to wait for the response to paging type 1 in RRC procedure.5000GUI value range:1~10000Actual value range:1~10000Unit:msDefault value:-Recommended Value:5000RrcInitDtTmrRRC initial DT timerDescription:A timer used to wait for initial direct transmission.5000GUI value range:1~10000Actual value range:1~10000Unit:msDefault value:-Recommended Value:5000RrcRlcAckCmpTmrRRC RLC completion acknowledgement timerDescription:A timer used to wait for the acknowledgement of radio link control (RLC) completion in RRC procedure.1000GUI value range:1~3000Actual value range:1~3000Unit:msDefault value:-Recommended Value:1000RbSetupRspTmrWait RB setup response timerDescription:A timer to RNC wait for the RB setup response from UE in the RB procedure.5000GUI value range:300~10000Actual value range:300~10000Unit:msDefault value:-Recommended Value:5000UeCapEnqRspTmrUE capability enquiry response timerDescription:A timer used to wait UE capability enquiry response .5000GUI value range:1~10000Actual value range:1~10000Unit:msDefault value:-Recommended Value:5000RbRecfgRspTmrWait RB reconfiguration response timerDescription:A timer used to wait for the RB reconfiguration response from UE in the RB procedure.5000GUI value range:300~10000Actual value range:300~10000Unit:msDefault value:-Recommended Value:5000RbRelRspTmrWait RB release response timerDescription:A timer to RNC wait for the RB release response from UE in the RB procedure.5000GUI value range:300~10000Actual value range:300~10000Unit:msDefault value:-Recommended Value:5000RlSetupRspTmrRL setup response timerDescription:A timer to RNC wait for the response to radio link setup request in the radio link procedure.5000GUI value range:1~10000Actual value range:1~10000Unit:msDefault value:-Recommended Value:5000RlRecfgReadyTmrRL reconfiguration timerDescription:A timer to RNC wait for the response to radio link reconfiguration prepare in the radio link procedure.5000GUI value range:1~10000Actual value range:1~10000Unit:msDefault value:-Recommended Value:5000RlRelRspTmrRL release timerDescription:A timer to RNC wait for the response to radio link deletion request in the radio link procedure.5000GUI value range:1~10000Actual value range:1~10000Unit:msDefault value:-Recommended Value:5000RlRstrTmrRL restoration timerDescription:A timer to RNC wait for radio link restoration indication in the radio link procedure.10000GUI value range:1~10000Actual value range:1~10000Unit:msDefault value:-Recommended Value:5000DrlAal2EstIndTmrDRL AAL2 establishment indication timerDescription:A timer to DRNC wait for AAL2 setup indication.5000GUI value range:1~10000Actual value range:1~10000Unit:msDefault value:-Recommended Value:5000DrlRecfgCmitTmrDRL reconfiguration commit timerDescription:A timer to DRNC wait for radio link reconfiguration commit.5000GUI value range:1~10000Actual value range:1~10000Unit:msDefault value:-Recommended Value:5000HoCellUpdateRspTmrHO cell update response timerDescription:A timer to RNC wait for the response to the cell update confirm from UE in forward handover procedure.5000GUI value range:1~10000Actual value range:1~10000Unit:msDefault value:-Recommended Value:5000HoPagingRspTmrHO paging response timerDescription:A timer to RNC wait for paging response in forward handover procedure.5000GUI value range:1~10000Actual value range:1~10000Unit:msDefault value:-Recommended Value:5000HoRelocReqTmrHO relocation request timerDescription:A timer to RNC wait for relocation request in forward handover procedure.5000GUI value range:1~10000Actual value range:1~10000Unit:msDefault value:-Recommended Value:5000HoAsuTmrHO active set update response timerDescription:A timer to RNC wait for the response to active set update in soft handover procedure.5000GUI value range:1~10000Actual value range:1~10000Unit:msDefault value:-Recommended Value:5000HoWtTrchRecfgRspTmrHO wait timer for TrCH or RB reconfiguration responseDescription:A timer to RNC wait for the response to the TrCH reconfiguration or RB reconfiguration response from UE in hard handover procedure.5000GUI value range:1~10000Actual value range:1~10000Unit:msDefault value:-Recommended Value:5000HoPhychRecfgTmrHO PhyCh reconfiguration timerDescription:A timer to RNC wait for the response to physical channel reconfiguration in hard handover procedure.5000GUI value range:1~10000Actual value range:1~10000Unit:msDefault value:-Recommended Value:5000RelocCmdTmrRelocation Command timerDescription:A timer to RNC wait for the relocation command message in relocation procedure.10000GUI value range:1~20000Actual value range:1~20000Unit:msDefault value:-Recommended Value:10000RelocIuRelCmdTmrRelocation Iu release command timerDescription:A timer to RNC wait for the Iu release command message in relocation procedure.45000GUI value range:1~60000Actual value range:1~60000Unit:msDefault value:-Recommended Value:45000RelocDataFwdTmrRelocation data forwarding timerDescription:A timer used for data forwarding in relocation procedure.20000GUI value range:1~20000Actual value range:1~20000Unit:msDefault value:-Recommended Value:20000RelocAnotherTmrRelocation another request timerDescription:A timer to RNC wait for another relocation request in relocation procedure.5000GUI value range:1~10000Actual value range:1~10000Unit:msDefault value:-Recommended Value:5000RelocCommitTmrRelocation commit timerDescription:A timer to RNC wait for rnsap relocation commit message in relocation procedure.15000GUI value range:1~20000Actual value range:1~20000Unit:msDefault value:-Recommended Value:15000RelocMobilConfTmrRelocation mobile info confirmation timerDescription:A timer to RNC wait for mobile information confirmation in relocation procedure.5000GUI value range:1~10000Actual value range:1~10000Unit:msDefault value:-Recommended Value:5000RelocPhychRecfgTmrRelocation PhyCh reconfiguration timerDescription:A timer to RNC wait for the response to physical channel reconfiguration in relocation procedure.5000GUI value range:1~10000Actual value range:1~10000Unit:msDefault value:-Recommended Value:5000RelocUtranHoCmpTmrRelocation Inter-RAT HO completion timerDescription:A timer to RNC wait for inter-RAT handover completion in relocation procedure.10000GUI value range:1~20000Actual value range:1~20000Unit:msDefault value:-Recommended Value:10000RelocFailIuRelCmdTmrRelocation failed Iu release command timerDescription:A timer to RNC wait for Iu release command in the failed relocation procedure.5000GUI value range:1~10000Actual value range:1~10000Unit:msDefault value:-Recommended Value:3000SysHoPsResumeTmrPS resume timer after SYSHODescription:A timer to RNC wait for PS RESUME after successful CS InterRAT handover.10GUI value range:1~255Actual value range:1~255Unit:minDefault value:-Recommended Value:10RrcSecrtModeCmpTmrRRC security mode completion timerDescription:A timer to RNC wait for the response to security mode command from UE in security mode procedure.5000GUI value range:1~10000Actual value range:1~10000Unit:msDefault value:-Recommended Value:5000UeCntCheckRspTmrUE counter check response timerDescription:A timer to RNC wait for the response to counter check in security mode procedure.5000GUI value range:1~10000Actual value range:1~10000Unit:msDefault value:-Recommended Value:5000CmchRsrcRspTmrCMCH RSRC response timerDescription:A timer to SRNC wait for the response to common transport channel resources request in the Iur common transport channel procedure.5000GUI value range:1~10000Actual value range:1~10000Unit:msDefault value:-Recommended Value:5000IuCSRelNoRABTmrIu CS Release protection timerDescription:A timer to Iu CS Release protection.300GUI value range:1~65535Actual value range:1~65535Unit:sDefault value:-Recommended Value:300IuPSRelNoRABTmrIu PS Release protection timerDescription:A timer to Iu PS Release protection.300GUI value range:1~65535Actual value range:1~65535Unit:sDefault value:-Recommended Value:300RrcConnRejWaitTmrWait Time In RRC Connection Reject MessageDescription:Wait time in RRC connection reject message, the time period the UE has to wait before repeating the rejected procedure of RRC connection.4GUI value range:0~15Actual value range:0~15Unit:sDefault value:-Recommended Value:4ExampleSet the timer used to wait for the response to RRC connection setup as 5000 ms.SET STATETIMER: RrcUeRspTmr=5000;

Sheet3