  • or Main Generator Leads with current ratings from 6 kA up to 50 kA, Isolated Phase Bus is the solution. Isolated Phase

    Bus systems are used exclusively for Main Generator Leads where minimal external electro-magnetic fields and maximum phase to phase fault protection is required.

    TECHNIBUS offers a complete line of Isolated Phase Bus systems for those situations calling for high currents with maximum integrity. TECHNIBUS can provide continuous current ratings from 1,200A up to 50,000A with short circuit ratings up to 900,000A.

    he conductor consists of high conductivity, conductor grade aluminum. Depending upon the diameter

    required, extruded tubes or tubes rolled of plate metal are used. The tubes shape permits exact calculation of current displacement and heat dissipation as well as the short circuit forces. Aluminum expansion elements with welded connections allow for thermal expansion of the conductor. Maintenance is not required.

    nclosures are also made of high conductivity, conductor grade aluminum. The enclosures are manufactured from rolled sheet or plate of variable diameters and wall thicknesses and are welded

    together by using the inert-gas-shielded-arc process. The enclosure is self-supporting up to a length of approximately 65 feet, allowing a free choice of the fixed points. Expansion joints in the form of aluminum bellows provided at the terminations permit thermal expansion.

    ast resin post insulators support the conductor and are arranged in the enclosure so as to ensure the proper clearance in air between the conductor and earthed enclosure. A sliding surface provided

    at the post insulator head permits relative movements between enclosure and conductor in an axial direction. One insulator of each support system is equipped with an adjustable spring-type element for compensating any variance in tube diameters during mounting as well as any conductor movements caused by a short-circuit.

    1501 Raff Road SW Canton, OH 44710 http://www.technibus.com [email protected] 330-478-6395

    Isolated Phase BusF

    Conductor (A)

    T

    Enclosure (B)

    E

    Post Insulators (C)

    C

    Please contact your local sales representative to request our complete Isolated Phase brochure.

    A BConductor Enclosure

    Post Insulator

    C

  • 1501 Raff Road SW Canton, OH 44710 http://www.technibus.com [email protected] 330-478-6395

    Typical Isolated Phase Bus configuration.

    Table for dimensions and locating distancesAll dimension sizes are in inches

    TECHNIBUS IPB DESIGN PLAN (65C RISE/40C AMBIENT, 60HZ)TECHNIBUS IPB DESIGN PLAN (65C RISE/40C AMBIENT, 60HZ)TECHNIBUS IPB DESIGN PLAN (65C RISE/40C AMBIENT, 60HZ)TECHNIBUS IPB DESIGN PLAN (65C RISE/40C AMBIENT, 60HZ)TECHNIBUS IPB DESIGN PLAN (65C RISE/40C AMBIENT, 60HZ)TECHNIBUS IPB DESIGN PLAN (65C RISE/40C AMBIENT, 60HZ)TECHNIBUS IPB DESIGN PLAN (65C RISE/40C AMBIENT, 60HZ)TECHNIBUS IPB DESIGN PLAN (65C RISE/40C AMBIENT, 60HZ)TECHNIBUS IPB DESIGN PLAN (65C RISE/40C AMBIENT, 60HZ)

    Rated Voltage

    Rated Current

    (D1) Cond Dia (in.)

    (D2) Encl Dia (in.)

    (A) Phs Spc (in)

    Wt./3-Phs FT.

    Watts Loss per 3-Phs Ft.

    Capacitance Pico-Farads per Ft./Phase

    Inductance -Henries per

    Ft/Phase

    15KV - 24KV -

    110/125 KV BIL

    - 50/60 KV Hi-

    Pot

    3000 4.00 21.63 26.75 112 160 10.1 0.100

    15KV - 24KV -

    110/125 KV BIL

    - 50/60 KV Hi-

    Pot

    6000 7.50 25.25 29.00 115 392 14.1 0.074

    15KV - 24KV -

    110/125 KV BIL

    - 50/60 KV Hi-

    Pot

    8000 11.00 28.75 31.50 139 528 17.8 0.058

    15KV - 24KV -

    110/125 KV BIL

    - 50/60 KV Hi-

    Pot

    9000 11.00 28.75 31.50 164 584 17.8 0.05815KV - 24KV

    - 110/125 KV

    BIL -

    50/60 KV Hi-Pot

    10000 14.50 32.25 36.00 163 694 21.4 0.04815KV - 24KV

    - 110/125 KV

    BIL -

    50/60 KV Hi-Pot

    11000 14.50 32.25 36.00 182 758 21.4 0.04815KV - 24KV

    - 110/125 KV

    BIL -

    50/60 KV Hi-Pot

    12000 18.00 35.75 41.50 215 698 25.1 0.041

    15KV - 24KV -

    110/125 KV BIL

    - 50/60 KV Hi-

    Pot

    14000 18.00 35.75 41.50 263 741 25.2 0.041

    15KV - 24KV -

    110/125 KV BIL

    - 50/60 KV Hi-

    Pot16000 21.50 39.38 47.63 302 838 28.6 0.036

    15KV - 24KV -

    110/125 KV BIL

    - 50/60 KV Hi-

    Pot 17000 25.25 42.75 51.50 304 946 32.9 0.032

    15KV - 24KV -

    110/125 KV BIL

    - 50/60 KV Hi-

    Pot20000 28.75 46.50 59.00 387 1090 36.0 0.029

    15KV - 24KV -

    110/125 KV BIL

    - 50/60 KV Hi-

    Pot

    22000 32.25 50.00 63.00 421 1198 39.50 0.026

    15KV - 24KV -

    110/125 KV BIL

    - 50/60 KV Hi-

    Pot

    24000 35.75 53.50 67.00 456 1306 43.00 0.024

    15KV - 24KV -

    110/125 KV BIL

    - 50/60 KV Hi-

    Pot

    26000 39.38 57.00 71.00 544 1294 47.50 0.02223KV - 27 KV 150 KV BIL

    80 KV Hi-Pot

    3000039.38 67.75 82.75

    626 1397 31.90 0.03323KV - 27 KV 150 KV BIL

    80 KV Hi-Pot 3200039.38 67.75 82.75

    670 1476 31.90 0.033