IT Cooling Solutions CyberCool Chillers

Upload: doannhi

Post on 26-Jun-2018

246 views

Category:

Documents


6 download

TRANSCRIPT

Page 1: IT Cooling Solutions · control, STULZ has established a leading position in air- conditioning technology. To meet the changing needs of the global market, our prod-

IT Cooling Solutions

CyberCool Chillers

Page 2: IT Cooling Solutions · control, STULZ has established a leading position in air- conditioning technology. To meet the changing needs of the global market, our prod-

2

STULZ quality – now setting standards in chiller technology

Through our commitment to product development and quality control, STULZ has established a leading position in air- conditioning technology.To meet the changing needs of the global market, our prod-uct portfolio has now been extended to include the new CyberCool Chiller range.

• High-qualitycomponentsfromleadingbrandmanufacturersand production certified to ISO 9001:2000 ensure the high level of quality and reliability you expect throughout the units' life.

Page 3: IT Cooling Solutions · control, STULZ has established a leading position in air- conditioning technology. To meet the changing needs of the global market, our prod-

3

• CyberCool presents a comprehensive range of compact chillers with cooling capacities from 36 to 235 kW, offering optimum choice and flexibility. CyberCool can be tailored to match your installation requirements through a range of standard options and intelligent control strategies, which make them amongst the most environmental friendly and energy-saving chillers on the market.

• STULZisrenownedforitsdependableapplicationsadvicetogether with the high level of technical support and after-sales service provided throughout installation, commission-ing and maintenance.

Page 4: IT Cooling Solutions · control, STULZ has established a leading position in air- conditioning technology. To meet the changing needs of the global market, our prod-

-10 °C 0 10 20 30 35

100 %

0 %

400

300

200

100

0

4

-10 °C 0 10 20 30 35

CyberCool Chillers are designed to work reliably and with the highest efficiency, all year round, regardless of local am-bient temperature conditions. The chiller uses sophisticated, demand-driven control strategies, with free cooling to take advantage of lower temperatures. This cuts back on compres-sor operation and generates energy savings of up to 40 %.

CyberCool units are designed for energy-saving and quiet operation.

• Speed-controlledcondenserfansforslow-runningoperationat low outside temperatures

• Quietandhighlyefficientscrollcompressors

• Reducednoiseemissionthroughtimingcontrol

CyberCool CSO series for maximum efficiency throughout the year

0 – 100 % Speed control range

Speed

Energy is saved thanks to fan speed control based on external tem-peratures

Ho

urs

per

yea

r

Statistical temperature profile using the city of Munich as an example

•Compact,fullypackagedandpre-wiredchillers for external installation

•3sizesand11modelswithacapacityrangefrom36to235kW

•Simpleandrapidinstallationand commissioning

•Externaltemperaturerangefrom -10°Cto+40°Casstandard

Page 5: IT Cooling Solutions · control, STULZ has established a leading position in air- conditioning technology. To meet the changing needs of the global market, our prod-

5

Flexibility and reliabilityAir-conditioningtechnology–fromcomforttoprecisionunits

Industrial technology

Process engineering

Page 6: IT Cooling Solutions · control, STULZ has established a leading position in air- conditioning technology. To meet the changing needs of the global market, our prod-

100 %

80 %

60 %

40 %

20 %

-20 0 30 °C

63 125 250 500 1000 2000 4000 8000

65 dBA

60

55

50

45

40

35

30

25

20

-20 -10 0 10 20 30 °C

6

100 %

0 %

Energy consumption of GE2 systemEnergy consumption of A system

An

nu

al e

ner

gy

con

sum

pti

on

(kW

h)

Comparison of annual energy consumption of an air-cooled system (A) and a GE2 free cooling system

Free cooling Mixed operation Compressor operation

“fr

ee c

oo

ling

Energy saving through free cooling and mixed operation

Sound spectrum of CyberCool CLO designcompared with other standard chiller units

Page 7: IT Cooling Solutions · control, STULZ has established a leading position in air- conditioning technology. To meet the changing needs of the global market, our prod-

100 %

90 %

80 %

70 %

60 %

50 %

40 %

30 %

20 %

10 %

7

Environmental compatibility and the consideration of life cycle costs play a major part when selecting chiller units. CyberCool units in CLO design have distinct advantages in this respect:

• Reductioninlifecyclecosts.Freecoolingoperationisavail-able as an option across the complete CyberCool range. The free cooling control strategy makes the best possible use of local ambient conditions, minimizing running costs and maximizing the chillers' operating life.

• Acousticallylinedcompressorenclosure

• Sound-optimiseddesignofcondenserfansinthelowspeed range

• Noiselevelreducedbyupto10dBA,correspondingtoahalving of the perceived noise

CyberCool CLO series – the new league in energy and noise reduction

Life cycle costs for 10 years without and with free cooling

CSO

781

A w

ith

ou

t fr

ee c

oo

ling

CLO

781

A

wit

h f

ree

coo

ling

7/1

2 °C

CLO

631

A w

ith

fr

ee c

oo

ling

10/

15 °

C

Investment costs

Operating costs over 10 years

CLO 1272A with optional extras

Page 8: IT Cooling Solutions · control, STULZ has established a leading position in air- conditioning technology. To meet the changing needs of the global market, our prod-

8

RS485RS232RS232RS485

CyberCool Chillers have the benefit of the STULZ C6000 enhanced micropro-cessor controller, which offers sophis-ticated control capabilities. This control-ler incorporates a convenient LCD inter-face that is highly regarded by clients of STULZ air-conditioning systems.

• Factorysettingsallowrapidanduncomplicated commissioning.

• Self-explanatoryuserguidancein

Windows technology and several languages.

Modem version Bus version

Alarmchannel

Scanning channel

Modem connection

Mobile phone

C6000–Sophisticatedcontrolsystemforintelligentoperation

Connection of up to 32 STULZ units (CyberCool, air-conditioning units) via the C6000 MIB gateway:

• STULZTeleCompTrolbuildingmanagementsystemviadirectbusormodem

• BMSofrecognisedmanufacturersviaModbus

• CommunicationviaIPprotocolsSNMP,HTTP

PC

Page 9: IT Cooling Solutions · control, STULZ has established a leading position in air- conditioning technology. To meet the changing needs of the global market, our prod-

9

C6000connectivitynetworksolutionsforin-houseandremotemonitoring

The STULZ Tele CompTrol BMS system

• MonitoringandcontrolofSTULZchillers and air-conditioning units

• Graphicdisplayofallunit parameters

• Monitoring,sendingandstoringofunit alarms

• AlarmforwardingwithfaultmessagetoPCormobilephoneviaSMS

BMS supplier Data protocol Gateways for the STULZ C6000 controller system

STULZ, TeleCompTrol

Other suppliers

SDC

Modbus RTUMIB7000

Other suppliers

Other suppliers

SNMP

HTTPWIB8000

Page 10: IT Cooling Solutions · control, STULZ has established a leading position in air- conditioning technology. To meet the changing needs of the global market, our prod-

10

Optional pump packages Optional pressure gauge

Options for the water circuit • Waterpressuregauge• Throttlevalve• Hydraulickit1(pumpplusaccessories)• Hydraulickit2(askit1plusstandbypump)• Hydraulickit3(askit1,butwithspeed-

controlledpump)• Hydraulickit4(askit3plusspeed-

controlledstandbypump)• Integrated/separatebuffertank• Free-coolingoperation• Evaporatorandpipeworktraceheating• Waterfilter

Mechanical options

• Anti-vibrationmounts• Specialpaintfinishes• Panel/floorpanelsystem

Optionsprovidingtheperfect solutionforeveryapplication

Page 11: IT Cooling Solutions · control, STULZ has established a leading position in air- conditioning technology. To meet the changing needs of the global market, our prod-

11

Optional free cooling

Options for control and electrics

• Temperaturetransmitterinflowpipe• Flowpipecontrol• Phasemonitoring• RemoteOn/Offconnection• BMSvolt-freecontacts• BMSmulti-interfaceboard• Powerfactorcorrection• Remoteoperation• TeleCompTrolremotecontrolsoftware• Alternativesupplyvoltages• Outsidetemperaturesensor• C6000extendedfunctionboard• Compressorsoftstart• Signallampforstatus/faultmessages• Electricalpanelheating

Options for the cooling circuit • Copper/coppercoolingcoil• Coilcorrosionprotection• Coilanti-vandalguard• Solenoidvalveinliquidpipes• Liquidrefrigerantreceiver24l• High/lowpressuregauge• Hotgasbypass• Hightemperaturekit• Winterkit• Pumpdownkit

Page 12: IT Cooling Solutions · control, STULZ has established a leading position in air- conditioning technology. To meet the changing needs of the global market, our prod-

12

You can rely on STULZ

Expert advice and planning support

Early planning support and expert advice set the course for achieving the best possible project solution. Stulz is renowned for its dependable appli- cations advice, with 35 years of experi-ence in air-conditioning technology. Through load calculations and energy analysis for CyberCool Chillers, STULZ can assist the planning engineer and system designer with project develop-ment.

Rapid installation and commissioning

CyberCool Chillers are of a compact design that is factory assembled and pre-wired to offer a fully packaged solu-tion ready for connection to power and water services. This ensures a rapid and uncomplicated installation for the con-tractor and very straightforward com-missioning. The controls are factory set, and any necessary adjustments to the operating parameters can be carried out on site by following the clear operating instructions provided. In addition, STULZ specialists are happy to assist with com-missioning, testing and certification.

Customer service without delay

CyberCool Chillers are manufactured from high-quality materials and com-ponents that have been checked and repeatedly tested during production. In the unlikely event of a fault, STULZ customer service is available at all times to ensure the continuous availability of the system.

Professional documentation

To assist the planning engineer and system designer from tender submission to project completion, STULZ provides professional documentation in the form of technical manuals, planning software and layout drawings.

Page 13: IT Cooling Solutions · control, STULZ has established a leading position in air- conditioning technology. To meet the changing needs of the global market, our prod-

13

• Expertadviceandplanningsupport

• Rapidinstallationandcommissioning

• Customerservicewithoutdelay

• Professional documentation

Page 14: IT Cooling Solutions · control, STULZ has established a leading position in air- conditioning technology. To meet the changing needs of the global market, our prod-

Kühlleistung, kW250

200

100

50

0

CSO 361

CSO 631

B

H

T

CSO 781

CSO 1022CSO 1272

CSO 1527CSO 1922

CSO 2352

CSO 882

CSO 441

CSO 511

CSO 631

CSO 1022

CSO 1272

CSO 1572

CSO 1922

CSO 2352

CSO 882

CSO 441CSO 511

CSO 361

CSO 781

T

H

B

14

Dimensions, mm W 2500/H 1945/D 1350 W 3000/H 2125/D 1500 W 4000/H 2125/D 1500

Cooling capacity in kW 250

200

150

100

50

36

Model CSO xxx A 361 441 511 631 781 882 1022 1272 1572 1922 2352Standard versionTechnical specifications: Cooling capacity1) kW 36.0 44.4 51.4 63.6 71.9 88.8 102.8 127.2 157.2 192.0 235.0Performancelevels 2 2 2 2 2 4 4 4 4 6 6

Noise dataSound level2) dBA 55 56 57 58 59 63 62 62 64 62 65

CompressorCompressor type ScrollNumberofcompressors 2 2 2 2 2 4 4 4 4 6 6Cooling circuits 1 1 1 1 1 2 2 2 2 2 2Oil type Diester oilOilquantity(percircuit) l 4 4 4 4 4 8 8 8 8 12 12Energy consumption kW 11.9 14.3 16.4 20.5 24.6 28.7 32.7 41.0 49.2 61.5 73.7

CoolantCoolant type R407cFillinglevel kg 16.0 17.2 18.0 20.0 23.5 2 x 16.0 2 x 17.5 2 x 19.0 2 x 23.0 2 x 24.5 2 x 26.0

EvaporatorEvaporator type PlateevaporatorCold water quantity m3/h 6.7 8.2 9.5 11.8 13.3 16.5 19.1 23.6 29.2 35.6 43.6Pressureloss,water-side kPa 57 60 61 56 51 32 36 32 35 42 54Waterconnection(internalthread) DN50 DN50 DN50 DN50 DN50 DN60 DN60 DN60 DN72 DN72 DN84

FanFantype AxialfanNumber(A/B)3) 3 3 3 3 3 4/8 6/8 8 8 10 10Nominalfanpower kW 0.66 0.66 0.66 0.66 0.66 0.86 0.86 0.86 0.86 0.86 0.86Airquantity m3/h 8,600 11,000 13,200 17,000 22,500 23,300 28,000 36,700 48,500 56,600 75,500

WeightShipping weight kg 780 780 785 800 840 1,526 1,596 1,675 1,715 2,092 2,210

Elektrical dataVoltage supply V/Ph/Hz 380-415/3~/50,NPowerconsumption,max. kVA 22.7 26.3 29.8 33.9 40.1 51.0 60.3 72.8 84.8 106.7 125.1Operating current, max. A 32.7 38.0 43.0 48.9 57.8 74.3 87.6 105.7 123.5 154.6 181.2Starting current A 100 116 132 151 181 146 170 199 236 240 284

1)Coldwater:7°C/12°C/Outsidetemperature:35°C;Glycol:30%2)SoundlevelindBAat5mcleardistance3)A:Standard,B:WithoptionalfreecoolingTechnicaldatasubjecttochangewithoutnotice.

TechnicalspecificationsoftheCyberCool CSO series

WD

Page 15: IT Cooling Solutions · control, STULZ has established a leading position in air- conditioning technology. To meet the changing needs of the global market, our prod-

CLO 1272

CLO 631CLO 511

CLO 361CLO 441

CLO 781CLO 882

CLO 1022

CLO 1572

T

H

B

15

Dimensions, mm W 2500/H 1945/D 1350 W 2800/H 1945/D 1350 W 3000/H 2125/D 1500 W 4000/H 2125/D 1500

Cooling capacity in kW 250

200

150

100

50

36

Model CLO xxx A 361 441 511 631 781 882 1022 1272 1572Low-energy and low-noise variantTechnical specifications: Cooling capacity1) kW 36.0 44.4 51.4 63.6 71.9 88.8 102.8 127.2 157.2Performancelevels 2 2 2 2 2 4 4 4 4

Noise dataSound level2) dBA 48 49 50 50 51 53 53 54 55

CompressorCompressor type ScrollNumberofcompressors 2 2 2 2 2 4 4 4 4Cooling circuits 1 1 1 1 1 2 2 2 2Oil type Diester oilOilquantity(percircuit) l 4 4 4 4 4 8 8 8 8Energy consumption kW 11.9 14.3 16.4 20.5 24.6 28.7 32.7 41.0 49.2

CoolantCoolant type R407cFillinglevel kg 16.0 17.2 18.0 22.0 25.0 2 x 16.0 2 x 17.5 2 x 19.0 2 x 23.0

EvaporatorEvaporator type PlateevaporatorCold water quantity m3/h 6.7 8.2 9.5 11.8 13.3 16.5 19.1 23.6 29.2Pressureloss,water-side kPa 57 60 61 56 51 32 36 32 35Waterconnection(internalthread) DN50 DN50 DN50 DN50 DN50 DN60 DN60 DN60 DN72

FanFantype AxialfanNumber 3 3 3 3 3 8 8 10 10Nominalfanpower kW 0.66 0.66 0.66 0.98 0.98 0.86 0.86 0.86 0.86Airquantity m3/h 8,600 11,000 13,200 16,500 21,600 23,300 28,000 33,200 43,000

WeightShipping weight kg 780 780 785 825 865 1,588 1,627 2,006 2,046

Elektrical dataVoltage supply V/Ph/Hz 380-415/3~/50,NPowerconsumption,max. kVA 22.7 26.3 29.8 35.8 41.9 53.5 62.7 75.2 87.5Operating current, max. A 32.7 38.0 43.0 51.6 60.5 77.8 91.1 109.2 126.9Starting current A 100 116 132 154 183 150 173 200 240

1)Coldwater:7°C/12°C/Outsidetemperature:35°C;Glycol:30%2)SoundlevelindBAat5mcleardistanceTechnicaldatasubjecttochangewithoutnotice

TechnicalspecificationsoftheCyberCool CLO series

WD

Page 16: IT Cooling Solutions · control, STULZ has established a leading position in air- conditioning technology. To meet the changing needs of the global market, our prod-

IT Cooling Solutions

Close to you all over the world.

... With specialist, competent partners in our subsidiaries and exclusive

sales and service partners around the world. Our five production sites are

inEurope,NorthAmericaandAsia.

www.stulz.com

STULZ Company Headquarters

D STULZ GmbH HolsteinerChaussee283.22457Hamburg Tel.:+49(40)5585-0.Fax:+49(40)5585-352. [email protected]

STULZ Subsidiaries

AUS STULZ AUSTRALIA PTY. LTD. 34BearingRoad . Seven HillsNSW2147 Tel.: +61(2)96744700 . Fax:+61(2)96746722 . [email protected]

CN STULZ AIR TECHNOLOGY SYSTEMS (SHANGHAI) CO., LTD. No.999ShenFuRoad, MinHang District . Shanghai 201108 . P.R.ChinaTel.:+86(21)54830270 . Fax:+86(21)54830271 . [email protected]

E STULZ ESPAÑA S.A. AvenidadelosCastillos1034.28918Leganés(Madrid) Tel.:+34(91)5178320.Fax:+34(91)5178321. [email protected]

F STULZ FRANCE S. A. R. L. 107,ChemindeRonde. 78290 Croissy-sur-Seine Tel.:+33(1)34804770.Fax:+33(1)34804779. [email protected]

GB STULZ U. K. LTD. FirstQuarter.BlenheimRd.. Epsom .SurreyKT199QN Tel.:+44(1372)749666.Fax:+44(1372)739444. [email protected]

I STULZ S.P.A. Via Torricelli, 3 .37067ValeggiosulMincio(VR) Tel.:+39(045)6331600.Fax:+39(045)6331635. [email protected]

IN STULZ-CHSPL (INDIA) PVT. LTD. 006, Jagruti Industrial Estate . Mogul Lane, Mahim . Mumbai - 400 016 Tel.:+91(22)56669446.Fax:+91(22)56669448. [email protected]

NL STULZ GROEP B. V. Postbus75.1180ABAmstelveen Tel.:+31(20)5451111.Fax:+31(20)6458764. [email protected]

NZ STULZ NEW ZEALAND LTD. Office71,300RichmondRd..GreyLynn.Auckland Tel.:+64(9)3603232.Fax:+64(9)3602180. [email protected]

PL STULZ POLSKA SP. Z O.O. BudynekMistral.Al.Jerozolimskie162. 02 – 342 Warszawa Tel.:+48(22)8833080.Fax:+48(22)8242678. [email protected]

USA STULZ AIR TECHNOLOGY SYSTEMS (SATS), INC. 1572 Tilco Drive .Frederick,MD21704 Tel.:+1(301)6202033.Fax:+1(301)6625487. [email protected]

ZA STULZ SOUTH AFRICA PTY. LTD. P.O.Box15687. Lambton 1414 .Gauteng Tel.:+27(11)8736806.Fax:+27(11)8733136. [email protected]

Sub

ject

to

chan

ge.

Err

ors

exc

epte

d. ·

10

00

XX

X01

-10

en·

©S

TULZ

Gm

bH

,Ham

bu

rg