FUNCTION

Halls for sports activities and gymnasiums

Buildings or objects are always realized to serve some purpose or to satisfy certain functions. Therefore it is worth to sum up, in general, the most important factors that influence the final design of a building (without a claim for completeness):

builders’ needs: function, aesthetics, expected lifetime, construction and operating (maintenance) costs

requirements of competent authorities (on EU, national or local levels), eg: town planning or town development aspects

technical requirements (construction legislation, regulations, standards, etc.)

available construction material, construction products and processes local aspects relating to the work site and to the execution of the

construction works (eg. soil conditions, weather or environmental impacts, execution processes, and time- and machinery needs, etc.)

The numerous conditions listed above contain both mandatory and more flexible aspects – even contradictory ones in certain cases – therefore, the technical specifitactions should be specified individually that can meet all the requirements at some expected level (even if at the cost of comprosies) and which become finally interpreted as ensuring a match with this wide-ranging conditions system. It is therefore has high importance that the economic construction of each building at the required technical quality level must take place on the

basis of an individual de-sign.

Among the requirements set out for buildings serving the purpose of sports and physical exercise, the most important one is a compliance with the given function. In the de-sign of school gym halls

or sports halls, the primary aspect is to provide the required space or proper dimensions for the purpose of sports or physical excerise. The dimensions needed for physical education at school are set out by applicable standards; the official dimensions of sports-ground or play-fields are also regulated in function of the given branch of sport, which sets the basis for specifying the required hall dimensions. Due to these requirements, these buildings are typically hall structures with large span and clear height. A sports hall must or can be supplemented by various service spaces (eg. store rooms, changing rooms, bathrooms, offices, conference rooms, etc.) specified partly by mandatory normative specifications and partly by individual builder needs.

TECHNICAL POSSIBILITIES

Lindab lightweight construction solutions

For the construction of gym halls and sports halls with confined spaces, excellent solutions are offered by Lindab’s lightweight steel structure construction products and the systems, subsystems that can be created by using these products.

The following are the main subsystems of Lindab’s lightweight hall structures: Primary framing structure in steel Secondary framing structures Roof- and wall-cladding systems Supplementary systems, accessories

The primary framing structure of Lindab halls is a spatial framework made from linearly sequenced planar frames and bracing systems. Three main frame types are available: solid-section frames are hot rolled, welded I-profile frames of variable cross-sections, and main lattice girder structures. Numerous further variants of these main types are possible, depending on further installations such as side-aisles, intermediate storey(s), crane-runway(s), etc. A tailor-made solution in conformity with builders’ needs (functional, aesthetics) and the technical requirements is realized in each case through individual design, that produces the required large dimensions (span, clear height), as well as the relevant optimised material consumption and, through this, economy. The surface protection solutions for the structural elements of main frames must be specified with view to needs and available options, which might be multi-layer painting or hot-dip galvanizing.

Upon the primary framing structure of halls, the so-called secondary load-bearing system is installed, which directly supports the roof- and wall sheeting and which transfers loads to the primary framing. Most frequently the secondary load-bearing system is constructed by using the optimized lightweight profiles of the Lindab Construline product family (linearly distributed load-bearing roof purlin- and wall-stud systems), ensuring excellent load-bearing capacities through high strength, and a long-lasting corrosion-resistance through the hot-dip galvanisation surface protection. The secondary framing can be realized by using Lindab Coverline structural elements too, using high-profile trapezoidal sheeting on roofs and structural wall-cassette products on walls.

The Sweden-based Lindab Group operates in the field of developing, manufacturing and selling of products and system solutions in steel for simplified construction. Since its foundation in 1959, Lindab has become continuously developing, determinant market player with enormous experience. The Hungarian daughter company, Lindab Kft. has been present in Hungary already for 20 years, operating by its own significant production capacity and excellent results. In this market segment, Lindab has got the widest and most complex product range (roof- and wall cladding products and systems, supporter elements, complete building structures and supplementary systems: rainwater system, roof safety systems, etc.) representing optimum solutions for residential buildings or industrial halls, new projects or renovations as well.

Lindab building solutions for gymnasiums and sport halls

Page 3: Lindab building solutions

The Lindab Coverline profiled sheeting products available with several coating types and in numberless colours provide safe and watertight roofing, and durable and aesthetical wall cladding not only for the gym hall itself but also for the service building block. This group of products offers several architectural solutions for the design of the external cladding: simple, lined-looking trapezoidal profiles in a range

of dimensions, and also with “design” pat-terns available option-ally; elegant sinusoidal profiles; facade wall-cassettes providing a strongly marked rec-tangular pattern (ECO and Premium types); or even standing seam sheetings (SRP, PLX)

are available. The sandwich panels of various types (all with steel sheet-ing at both sides with a thermal-insulation core in between) allow for a quick, thermally insulated cladding of large surfaces.

It is of high importance that besides its main framing and sheeting components, Lindab offers a wide range of accessories system

as well: the Rainline roof drainage system, the Protectline system for roof safety (snow fences, roof walkways, roof- and wall-ladders), roof ventilation elements, roof foils, self-drilling screws, sealing profiles ensure a perfect design for the tiniest details.

It is important to note here, that the products and technical solutions enumerated above allow for a highly free and flexible design. In certain cases, the wall structures of complete hall buildings can be realized by using Lindab components and solutions (steel framework structure, roof- and wall-cladding, roof drainage products and the relevant accessories), while in other cases Lindab products can be flexibly combined with structures made from other materials (eg. prefabricated reinforced concrete framings combined with Lindab lightweight roof- and wall-claddings) in order to ensure the best and most economic realization of works.

Professional support

In addition to the developing and manufacturing of excellent quality products, from the very beginning Lindab has attached importance to being able to provide professional and technical support to companies and persons playing a role in the construction process, at the highest possible level and in the highest number of fields all through the design and installation of its products. The quickest way to have access to general information is to use our web site (www.lindab.hu), while deatiled professional information is available at the Lindab Designer Portal that can be accessed via the website. In the following sections, we provide a short summary of the services Lindab provides, broken down to target groups:

Builders, investors: a collection of references, professional consultation, putting up designer- and contractor-contacts, preparing preliminary quotations free of charge (in accordance with the level the technical specifications have been elaborated to)

Designers: design-er guides, technical guides for applica-tions, design soft-wares, professional consultation

Contractor: short lead times and flexibil-ity due to local produc-tion, excellent logistics, minimum amounts of construction wastes due to a manufacture with accurate dimen-sions, safe packaging, professional consulta-tion.

Lindab building solutions for gymnasiums and sport halls

Advantages offered by Lindab products and systems - for all participants high-strength steel raw material – high load-bearing capacity,

spanning over large spans hot-dip galvanization for surface protection – excellent corrosion

protection, hardwearing quality recyclable steel materials – environmentally friendly products a wide range of profiles and colours for cladding components -

aesthetical appearance, at a variety of levels light weight – small loads to foundations, low transporation

costs, fast realization

mounted, installed, dry technology – fast construction works, short realization times, faster return of investment

accurate manufacture dimensions – low amounts of wastes on site

complete system (framings, roof- and wall-cladding, roof drainage, roof safety, accessories)

variable system components – flexible, variable applications outstanding services (for designers, contractors and

builders)

SERVICES

Page 4: Lindab building solutions

Modell hall no. 1 presents an example for halls serving the function of school sports and leisure activities to the minimum level. This 15-m wide and 30-m long sports hall of 450 m2, with a high roof pitch suitable to hold gym lesson of elementary schools or secondary educational institutions operating with not more than eight classes (according to the provisions of former Hungarian standards, the MSZ 24203 series); further, it is suited to accommodate a volleyball- and tennis-court in official tournament dimensions. Of course, for the purpose of mass sports and leisure activities, the hall can accomodate handball-, basketball- and indoor footbal courts as well, whose dimensions are less than the official requirements.At the gable end of the hall building, a service block of minimum floor area (60 m2) is attached to the building, accomodating an entrance for persons, as well as few indispensable rooms (store room, locker room for a couple of people).

SPECTACULAR DRAWINGSGYM HALL DIMENSIONS

Width (m) 15.0

Length (m) 30.0

Height of the eaves (m) 8.0

Roof pitch (°/%) 20°

Floor area 450.0

OFFICIAL COURT DIMENSIONS THE HALL CAN ACCOMMODATE

volleyball (9x18m) – 1 court

tennis (10,97x23,77m) – 1 court

HALL BUILDING STRUCTURE

Primary framingSteel framing structure, made from profiles produced by hot roll forming

Secondary framingLindab Construline steel purlin- and wall-stud system

Roof cladding

Thermal-insulated mounted sandwhich structure (Lindab tile-effect roofing, roof foil, thermal insulation, vapour-barrier, trapezoidal sheets)

Wall cladding

Thermal-insulated mounted sandwich structure (Lindab trapezoidal profiles, thermal insulation, vapour-barrier, trapezoidal sheets)

Roof drainageLindab Rainline rainwater system

SERVICE BUILDING BLOCK ATTACHED TO THE HALL (OPTIONAL)

Place of attachment at gable end

Width (m) 10.0

Length (m) 6.0

Height of the eaves (m) 3.0

Roof pitch (°/%) 20°

Floor area 60.0

FUNCTIONALITY OPTIONS FOR THE SERVICE SPACES

Windbreak room, entrance space

Store room, storage space

Changing rooms, lockers

Model hall no. 1

Please note: The model halls, buildings we present here are intended for inspiration, which can be used as starting point for the builders’ own designs, as an aid

Page 5: Lindab building solutions

-0,20

+0,80+1,30

+2,20

6 000 500 30 00015 000

6 00050030 000 15 000

+2,80

-0,20

+2,20

+1,30

+2,20

-0,20

+0,80

-0,20

+0,80

±0,00

+4,00

+5,80

+1,30

+2,20

+4,00

+5,80

-0,20

+3,00+4,00

+5,80

15 000

+0,80

+3,00 +3,00

+0,80 +0,80

20,00°

20,00°

Projekt neve: Rajz neve:

Készítette:

Ellenőrizte:

Méretarány:

Dátum:

2051 Biatorbágy, Állomás u. 1/aTel.: 06-23/531-100Fax.: 06-23/310-703Adószám: 10539260-2-13

Rajzszáma:

Referenciaszám:

Megrendelő:

2012. november

LINDAB TORNACSARNOKMINTAÉPÜLET 1.

Homlokzatok

FRONT FACADE

BACKSIDE FACADE

RIGHTSIDE FACADE

LEFTSIDE FACADE

1

4

23

5

1

4

23

5 5

4

2

2

4

3LVP 20 tarpezoid sheet, .................(...) szín, Classic bevonat

Lindab Rainline 150/100 ereszcsatorna, .................(...) szín, Elite bevonat

Vakolt lábazati fal, .................(...) szín

21

45

LPA Maxi tile effect sheet, .................(...) colour, Classic coated

Ablak szegélyezés, Lindab síklemez, .................(...) szín, Classic bevonat T-1/IV.

GROUND PLAN

SECTIONS

ELEVATION

450 m22

200

1501

500

1 50

01

500

1 50

085

0

anchoring level

floor level

eaves height

ridge height

8 00

0

15 000

7 981

500

1508811 070

1 0701 070

1 0701 070

1 070

1 030

±0,00

-1,40-0,20

±0,00

+0,80

+7,80

+10,53

20,00°

"LS" Euro section primary framing(according to static specifications)

brick footing foundations (according to static specifications)

Projekt neve: T-1/II.

2

1

1

2

Rajz neve:

Készítette:

Ellenőrizte:

Méretarány:

Dátum:

2051 Biatorbágy, Állomás u. 1/aTel.: 06-23/531-100Fax.: 06-23/310-703Adószám: 10539260-2-13

Rajzszáma:

Referenciaszám:

Megrendelő:

2012. november

LINDAB TORNACSARNOKMINTAÉPÜLET 1.

LVP 20 tarpezoid sheet"Z" purlin (Z120)12 cm heat insulation between*LPZ 110 vapour barrierLVP 20 tarpezoid sheetsteel frame structure

3 3

A-A metszet

2-3 cm sport flloring8-10 cm floor slabPE technological membrane8-10 cm step-proof heat insulationdamp-proof membrane15-20 reinforced concrete flooring25-30 cm gravel filloriginal soil

*according to therno-technical specificationsexternal dimensions of primary frame

exte

rnal

eav

es h

eigh

t of f

ram

e st

ruct

ure

LPA Maxi tile effect sheetLTF 180 breathable construction foil"Z" purlin (Z200)15 cm heat insulation between*LPZ 110 vapour barrierLVP 20 tarpezoid sheetsteel frame structure

2 20

015

01 50

01

500

1 50

01

500

850

anchoring level

floor level

eaves height

ridge height

8 00

0

15 000

7 981

500

1508811 070

1 0701 070

1 0701 070

1 070

1 030

±0,00

-1,40-0,20

±0,00

+0,80

+7,80

+10,53

20,00°

"LS" Euro section primary framing(according to static specifications)

brick footing foundations (according to static specifications)

Projekt neve: T-1/II.

2

1

1

2

Rajz neve:

Készítette:

Ellenőrizte:

Méretarány:

Dátum:

2051 Biatorbágy, Állomás u. 1/aTel.: 06-23/531-100Fax.: 06-23/310-703Adószám: 10539260-2-13

Rajzszáma:

Referenciaszám:

Megrendelő:

2012. november

LINDAB TORNACSARNOKMINTAÉPÜLET 1.

LVP 20 tarpezoid sheet"Z" purlin (Z120)12 cm heat insulation between*LPZ 110 vapour barrierLVP 20 tarpezoid sheetsteel frame structure

3 3

A-A metszet

2-3 cm sport flloring8-10 cm floor slabPE technological membrane8-10 cm step-proof heat insulationdamp-proof membrane15-20 reinforced concrete flooring25-30 cm gravel filloriginal soil

*according to therno-technical specificationsexternal dimensions of primary frame

exte

rnal

eav

es h

eigh

t of f

ram

e st

ruct

ure

LPA Maxi tile effect sheetLTF 180 breathable construction foil"Z" purlin (Z200)15 cm heat insulation between*LPZ 110 vapour barrierLVP 20 tarpezoid sheetsteel frame structure

2 20

015

01 50

01

500

1 50

01

500

850

anchoring level

floor level

eaves height

ridge height

8 00

0

15 000

7 981

500

1508811 070

1 0701 070

1 0701 070

1 070

1 030

±0,00

-1,40-0,20

±0,00

+0,80

+7,80

+10,53

20,00°

"LS" Euro section primary framing(according to static specifications)

brick footing foundations (according to static specifications)

Projekt neve: T-1/II.

2

1

1

2

Rajz neve:

Készítette:

Ellenőrizte:

Méretarány:

Dátum:

2051 Biatorbágy, Állomás u. 1/aTel.: 06-23/531-100Fax.: 06-23/310-703Adószám: 10539260-2-13

Rajzszáma:

Referenciaszám:

Megrendelő:

2012. november

LINDAB TORNACSARNOKMINTAÉPÜLET 1.

LVP 20 tarpezoid sheet"Z" purlin (Z120)12 cm heat insulation between*LPZ 110 vapour barrierLVP 20 tarpezoid sheetsteel frame structure

3 3

A-A metszet

2-3 cm sport flloring8-10 cm floor slabPE technological membrane8-10 cm step-proof heat insulationdamp-proof membrane15-20 reinforced concrete flooring25-30 cm gravel filloriginal soil

*according to therno-technical specificationsexternal dimensions of primary frame

exte

rnal

eav

es h

eigh

t of f

ram

e st

ruct

ure

LPA Maxi tile effect sheetLTF 180 breathable construction foil"Z" purlin (Z200)15 cm heat insulation between*LPZ 110 vapour barrierLVP 20 tarpezoid sheetsteel frame structure

Pm: 1 300

900

900

Pm: 1 30090

090

0

Pm

: 1 3

00

900900

Pm

: 1 3

00

900900

2 4002 400

2 4001 000

2 4001 000

Pm: 1 300

900

900

Pm: 1 300

900

900 Pm

: 4 0

00

4 0001 800

Pm: 4

000

4 0001 800

Pm: 4

000

4 0001 800 3 000

3 000

Pm: 4 000

4 00

01

800

Pm: 4 000

4 00

01

800

Pm: 4 000

4 00

01

800

Pm: 4 000

4 00

01

800

Pm: 4 000

4 00

01

800

Pm: 4 000

1 80

04

000

Pm: 4 000

1 80

04

000

Pm: 4 000

1 80

04

000

Pm: 4 000

1 80

04

000

Pm: 4 000

1 80

04

000

6 000 500 6 000 6 000 6 000 6 000 6 000

6 500 30 000

2 50

010

000

2 50

0

15 0

005

000

5 00

05

000

6 000 500 1 000 4 000 1 000 1 000 4 000 1 000 1 000 4 000 1 000 1 0004 000 1 000 1 000

4 000 1 000

longitudinal bracinglongitudinal bracing

longitudinal bracinglongitudinal bracing

I. IV. VI. VII.V. VIII.II. III.

AA

Projekt neve: Rajz neve:

Készítette:

Ellenőrizte:

Méretarány:

Dátum:

2051 Biatorbágy, Állomás u. 1/aTel.: 06-23/531-100Fax.: 06-23/310-703Adószám: 10539260-2-13

Rajzszáma:

Referenciaszám:

Megrendelő:

2012. november

T-1/I.AlaprajzLINDAB TORNACSARNOK

MINTAÉPÜLET 1.

B

A

SPORTS HALL450 m2

sports flooring

VOLLEYBALL

TENNIS

SERVICE BLOCK60 m2

ceramic

-0,20

±0,00

+0,80

+3,00

-0,20

±0,00

+0,80

+7,80

+10,53

±0,00

6 000 500 6 000 6 000 6 000 6 000 6 000

brick footing foundations (according to static specifications)

Projekt neve:B-B metszet

3

1

2

Rajz neve:

Készítette:

Ellenőrizte:

Méretarány:

Dátum:

2051 Biatorbágy, Állomás u. 1/aTel.: 06-23/531-100Fax.: 06-23/310-703Adószám: 10539260-2-13

Rajzszáma:

Referenciaszám:

Megrendelő:

2012. november

LINDAB TORNACSARNOKMINTAÉPÜLET 1.

T-1/III.

1

ORDER OF LAYERS:

2 3LVP 20 tarpezoid sheet"Z" purlin (Z120)12 cm heat insulation between*LPZ 110 vapour barrierLVP 20 tarpezoid sheetsteel frame structure

2-3 cm sport flloring8-10 cm floor slabPE technological membrane8-10 cm step-proof heat insulationdamp-proof membrane15-20 reinforced concrete flooring25-30 cm gravel filloriginal soil

*according to therno-technical specifications

LPA Maxi tile effect sheetLTF 180 breathable construction foil"Z" purlin (Z200)15 cm heat insulation between*LPZ 110 vapour barrierLVP 20 tarpezoid sheetsteel frame structure

2 20

015

01 50

01

500

1 50

01

500

850

anchoring level

floor level

eaves height

ridge height

8 00

0

15 000

7 981

500

1508811 070

1 0701 070

1 0701 070

1 070

1 030

±0,00

-1,40-0,20

±0,00

+0,80

+7,80

+10,53

20,00°

"LS" Euro section primary framing(according to static specifications)

brick footing foundations (according to static specifications)

Projekt neve: T-1/II.

2

1

1

2

Rajz neve:

Készítette:

Ellenőrizte:

Méretarány:

Dátum:

2051 Biatorbágy, Állomás u. 1/aTel.: 06-23/531-100Fax.: 06-23/310-703Adószám: 10539260-2-13

Rajzszáma:

Referenciaszám:

Megrendelő:

2012. november

LINDAB TORNACSARNOKMINTAÉPÜLET 1.

LVP 20 tarpezoid sheet"Z" purlin (Z120)12 cm heat insulation between*LPZ 110 vapour barrierLVP 20 tarpezoid sheetsteel frame structure

3 3

A-A metszet

2-3 cm sport flloring8-10 cm floor slabPE technological membrane8-10 cm step-proof heat insulationdamp-proof membrane15-20 reinforced concrete flooring25-30 cm gravel filloriginal soil

*according to therno-technical specificationsexternal dimensions of primary frame

exte

rnal

eav

es h

eigh

t of f

ram

e st

ruct

ure

LPA Maxi tile effect sheetLTF 180 breathable construction foil"Z" purlin (Z200)15 cm heat insulation between*LPZ 110 vapour barrierLVP 20 tarpezoid sheetsteel frame structure

Possible application: sports hall of elementary school with maximum eight classes, or secondary educational institution

-0,20

+0,80+1,30

+2,20

6 000 500 30 00015 000

6 00050030 000 15 000

+2,80

-0,20

+2,20

+1,30

+2,20

-0,20

+0,80

-0,20

+0,80

±0,00

+4,00

+5,80

+1,30

+2,20

+4,00

+5,80

-0,20

+3,00+4,00

+5,80

15 000

+0,80

+3,00 +3,00

+0,80 +0,80

20,00°

20,00°

Projekt neve: Rajz neve:

Készítette:

Ellenőrizte:

Méretarány:

Dátum:

2051 Biatorbágy, Állomás u. 1/aTel.: 06-23/531-100Fax.: 06-23/310-703Adószám: 10539260-2-13

Rajzszáma:

Referenciaszám:

Megrendelő:

2012. november

LINDAB TORNACSARNOKMINTAÉPÜLET 1.

Homlokzatok

FRONT FACADE

BACKSIDE FACADE

RIGHTSIDE FACADE

LEFTSIDE FACADE

1

4

23

5

1

4

23

5 5

4

2

2

4

3LVP 20 tarpezoid sheet, .................(...) szín, Classic bevonat

Lindab Rainline 150/100 ereszcsatorna, .................(...) szín, Elite bevonat

Vakolt lábazati fal, .................(...) szín

21

45

LPA Maxi tile effect sheet, .................(...) colour, Classic coated

Ablak szegélyezés, Lindab síklemez, .................(...) szín, Classic bevonat T-1/IV.

1. Lindab LPA Maxi tile effect sheet black (015) colour, Classic coating

2. Lindab LVP 20 trapezoidal sheet dark grey (087) colour, Classic coating

3. Lindab Rainline 150/100 rain gutter, white (001) colour, Elite coating

4. Plastered plinth wall, grey

5. Window flashing, Lindab sheet, white (001) colour, Classic coating

Page 6: Lindab building solutions

GYM HALL DIMENSIONS

Width (m) 30.0

Length (m) 30.0

Height of the eaves (m) 10.0

Roof pitch (°/%) 10%

Floor area 900.0

OFFICIAL COURT DIMENSIONS THE HALL CAN ACCOMMODATE

volleyball (9x18m) – 2 db

tennis (10,97x23,77m)– 2 db

basketball (15x28m)– 1 db

HALL BUILDING STRUCTURES

Primary framingSteel farming structure, variable cross section welded sections

Secondary framingLindab Construline steel purlin- and wall-stud system

Roof cladding Lindab sandwichpanel

Wall claddingLindab sandwichpanel (laid horizontally); 4m tall plinth wall beneath

Roof drainageLindab Rainline rainwater system

SERVICE BUILDING BLOCK ATTACHED TO THE HALL (OPTIONAL)

Place of attachment to hall at gable end

Width (m) 10.0

Length (m) 30.0

Height of eaves (m) 3.5

Roof pitch (°/%) 10%

Floor area 300.0

FUNCTIONALITY OPTIONS FOR THE SERVICE SPACE

Windbreak room, entrance space

Changing rooms, lockers

Store room, storage space

Toilet, shower

Model hall no. 2

Model hall no. 2 presents an example for halls serving the function of school sports and leisure adctivities in an average, comfortable way. This 30-m wide and 30-m long sports hall of 900 m2, with a gentle roof pitch and an eaves height of ~10m is suitable to hold gym lessons of elementary schools or secondary educational institutions operating with not more than sixteen classes, or even special needs education with up to eight classes (according to the provisions of former Hungarian standards, the MSZ 24203 series); further it is suited to accommodate volleyball-, tennis- and basketball-court. Of course, for the purpose of mass sports and leisure activities, the hall can accommodate handball- and indoor footbal-courts as well, whose dimensions are less than the official requirements. At the gable end of the hall building a single-storey, lean-to roofed social block with a floor area of ~300 m2 is attached to the building, that serves the social functions adequatelly. It is accommodating rooms for storage of sport equipment and also spaces for personal needs (locker room, bathroom, toilet).

SPECTACULAR DRAWINGS

Please note: The model halls, buildings we present here are intended for inspiration, which can be used as a starting point for the builders’ own designs, as an aid.

Page 7: Lindab building solutions

Pm: 4 000

3 00

01

500

Pm: 4 000

3 00

01

500

Pm: 4 000

3 00

01

500

Pm: 4 000

3 00

01

500

Pm: 4 000

3 00

01

500

Pm: 4 000

3 00

01

500

Pm: 4 000

3 00

01

500

Pm: 4 000

3 00

01

500

Pm: 4 000

3 00

01

500

Pm: 4 000

3 00

01

500

Pm: 4 000

3 00

01

500

Pm: 4 000

3 00

01

500

Pm: 4 000

3 00

01

500

Pm: 4 000

3 00

01

500

Pm: 4 0003

000

1 50

0Pm: 4 000

3 00

01

500

Pm: 4 000

3 00

01

500

Pm: 4 000

3 00

01

500

Pm: 4

00 0

1 5003 000

Pm: 4

00 0

1 5003 000

Pm: 4

00 0

1 5003 000

Pm: 4

00 0

1 5003 000

Pm: 4

00 0

1 5003 000

Pm: 4

00 0

1 5003 000

Pm: 4

00 0

1 5003 000

Pm: 4

00 0

1 5003 000

Pm: 4

00 0

1 5003 000

Pm: 4

00 0

1 5003 000

Pm: 4

00 0

1 5003 000

Pm: 4

00 0

1 5003 000

Pm: 4

00 0

1 5003 000

Pm: 4

00 0

1 5003 000

Pm: 4

00 0

1 5003 000 3 000

3 000

Pm: 4 000

1 50

03

000

Pm: 4 000

1 50

03

000

Pm: 4 000

1 50

03

000

Pm: 4 000

1 50

03

000

Pm: 4 000

1 50

03

000

Pm: 4 000

1 50

03

000

Pm: 4 000

1 50

03

000

Pm: 4 000

1 50

03

000

Pm: 4 000

1 50

03

000

Pm: 4 000

1 50

03

000

Pm: 4 000

1 50

03

000

Pm: 4 000

1 50

03

000

Pm: 4 000

1 50

03

000

Pm: 4 000

1 50

03

000

Pm: 4 000

1 50

03

000

Pm: 900

1 50

01

200

Pm: 900

1 50

01

200

Pm: 900

1 50

01

200

1 00

02

400

Pm: 900

1 20

01

500

Pm: 900

1 20

01

500

Pm: 900

1 20

01

500

Pm: 900

1 20

01

500

Pm: 9

00

1 5001 200

Pm: 9

00

1 5001 200

Pm: 9

00

1 5001 200

Pm: 9

00

1 5001 200

Pm: 9

00

1 5001 200

Pm: 9

00

1 5001 200

Pm: 9

00

1 5001 200

Pm: 9

00

1 5001 200

Pm: 9

00

1 5001 200

Pm: 9

001 5001 200

Pm: 9

00

1 5001 200

Pm: 9

00

1 5001 200

2 4002 400

2 4001 000

2 4001 000

10 000 500 30 000

30 0

00

6 00

06

000

6 00

06

000

6 00

0

5 000 5 000 500 6 000 6 000 6 000 6 000 6 000

30 0

00

6 00

06

000

6 00

06

000

6 00

0

5 000 5 000 500 750 1 500 1 500 1 500750 750

1 500 1 500 1 500750 750

1 500 1 500 1 500750 750

1 500 1 500 1 500750 750

1 500 1 500 1 500 750

longitudinal bracing

longitudinal bracing

longitudinal bracing

longitudinal bracing

Projekt neve:

LINDAB TORNACSARNOKMINTAÉPÜLET 2.

T-2/I.Alaprajz

BASKETBALL

Rajz neve:

Készítette:

Ellenőrizte:

Méretarány:

Dátum:

2051 Biatorbágy, Állomás u. 1/aTel.: 06-23/531-100Fax.: 06-23/310-703Adószám: 10539260-2-13

Rajzszáma:

Referenciaszám:

Megrendelő:

2012. november

SPORTS HALL900 m2

sports flooring

VI. VII.V. VIII.

AA

I. II.

SERVICE BLOCK300 m2ceramic

IV.III. IX.

B

A

VOLLEYBALL

TENNIS

VOLLEYBALL

TENNIS

B B

6 0006 0006 0006 0006 000

+0,90

+2,40

-0,20

+9,80

+11,30

+12,64

+0,90

+2,40

+0,90

+2,40

6 0006 0006 0006 0006 000

-0,20

+9,80

+11,30

+12,64

6 0006 0006 0006 0006 0005005 0005 000

+12,64

+2,80

+4,00

+7,00

+4,00

+7,00

+4,00

+7,00

6 000 6 000 6 000 6 000 6 000 500 5 000 5 000

-0,20

+3,30

+4,33

+11,30

+12,64

LEFTSIDE FACADE

RIGHTSIDE FACADE

3Vakolt lábazati fal, .................(...) szín

21

45

Lindab tetőpanel .................(...) szín

BACKSIDE FACADE

FRONT FACADE

Projekt neve: Rajz neve:

Készítette:

Ellenőrizte:

Méretarány:

Dátum:

2051 Biatorbágy, Állomás u. 1/aTel.: 06-23/531-100Fax.: 06-23/310-703Adószám: 10539260-2-13

Rajzszáma:

Referenciaszám:

Megrendelő:

2012. november

HomlokzatokLINDAB TORNACSARNOK

MINTAÉPÜLET 2.

2

1

4

3

2

Lindab PLX korcolt lemezfedés, .................(...) szín, Elite bevonat

31

2

2

Lindab falpanel.................(...) szín

Lindab Rainline 190/120 ereszcsatorna, .................(...) szín, Elite bevonat

4

4

55

6

5

Ablak szegélyezés, Lindab síklemez, .................(...) szín, Classic bevonat

67

Vakolt téglafalazat, .................(...) szín

T-2/IV.

7 7

7

±0,00

3 000

30 000

anchoring level

floor level

eaves height

ridge height

10 0

00

500 1 417 1 500 1 500 1 500 1 500 1 500 1 500 1 500 1 500 1 657

500

15 075

1 20

04

000

6 00

0

-1,40-0,20

±0,00

+3,80

+9,80

+11,30

+12,64

5,71° = 10 %

brick footing

"LH" welded "I" section frame with variable cross section(according to static specifications)

foundations (according to static specifications)

5

1

2

(external dimensions of primary frame)

LINDAB TORNACSARNOKMINTAÉPÜLET 2.

T-2/II.Projekt neve: Rajz neve:

Készítette:

Ellenőrizte:

Méretarány:

Dátum:

2051 Biatorbágy, Állomás u. 1/aTel.: 06-23/531-100Fax.: 06-23/310-703Adószám: 10539260-2-13

Rajzszáma:

Referenciaszám:

Megrendelő:

2012. november

A-A metszet

(ext

erna

l eav

es h

eigh

t of f

ram

e st

ruct

ure)

1 5Lindab wall panel 100 mm (horizontal)steel frame structure

ORDER OF LAYERS:

Lindab roof panel 100 mm"Z" purlin (Z200)steel frame structure

2 2-3 cm sport flloring8-10 cm floor slabPE technological membrane8-10 cm step-proof heat insulationdamp-proof membrane15-20 reinforced concrete flooring25-30 cm gravel filloriginal soil

6 0006 0006 0006 0006 0005005 0005 000

±0,00 -0,20

+3,80

+11,30

+12,64

5,71° = 10 %

brick footing

foundations (according to static specifications)

5

B-B metszet T-2/III.LINDAB TORNACSARNOK

MINTAÉPÜLET 2.

Projekt neve: Rajz neve:

Készítette:

Ellenőrizte:

Méretarány:

Dátum:

2051 Biatorbágy, Állomás u. 1/aTel.: 06-23/531-100Fax.: 06-23/310-703Adószám: 10539260-2-13

Rajzszáma:

Referenciaszám:

Megrendelő:

2012. november

1

2

4

3

1 Lindab wall panel 100 mm (horizontal)steel frame structure

ORDER OF LAYERS:

Lindab roof panel 100 mm"Z" purlin (Z200)steel frame structure

2 3 Lindab PLX standing seam roofingwooden boarding (2,4 cm)5x5 cm counter batten every 1 m with ventilated air spaceLindab LTP 20 trapezoid cladding (2 cm)LTF 180 breathable construction foilLindab Z 200 purlin system20 cm mineral wool heat insulation betweenLPZ 110 vapour barriergypsum plasterboard supporting frame (2 cm)2 ply gypsum plasterboard cladding (2,5 cm)

4 interior plaster (1 cm)hollow block brick wall (38 cm)facade heat insulation system (5 cm)exterior plaster (1,5 cm)

5 2-3 cm sport flloring8-10 cm floor slabPE technological membrane8-10 cm step-proof heat insulationdamp-proof membrane15-20 reinforced concrete flooring25-30 cm gravel filloriginal soil

GROUND PLAN

SECTIONS

ELEVATION

900 m2Possible application: elementary and secondary schools with eight to sixteen classes and special needs education

6 0006 0006 0006 0006 0005005 0005 000

±0,00 -0,20

+3,80

+11,30

+12,64

5,71° = 10 %

brick footing

foundations (according to static specifications)

5

B-B metszet T-2/III.LINDAB TORNACSARNOK

MINTAÉPÜLET 2.

Projekt neve: Rajz neve:

Készítette:

Ellenőrizte:

Méretarány:

Dátum:

2051 Biatorbágy, Állomás u. 1/aTel.: 06-23/531-100Fax.: 06-23/310-703Adószám: 10539260-2-13

Rajzszáma:

Referenciaszám:

Megrendelő:

2012. november

1

2

4

3

1 Lindab wall panel 100 mm (horizontal)steel frame structure

ORDER OF LAYERS:

Lindab roof panel 100 mm"Z" purlin (Z200)steel frame structure

2 3 Lindab PLX standing seam roofingwooden boarding (2,4 cm)5x5 cm counter batten every 1 m with ventilated air spaceLindab LTP 20 trapezoid cladding (2 cm)LTF 180 breathable construction foilLindab Z 200 purlin system20 cm mineral wool heat insulation betweenLPZ 110 vapour barriergypsum plasterboard supporting frame (2 cm)2 ply gypsum plasterboard cladding (2,5 cm)

4 interior plaster (1 cm)hollow block brick wall (38 cm)facade heat insulation system (5 cm)exterior plaster (1,5 cm)

5 2-3 cm sport flloring8-10 cm floor slabPE technological membrane8-10 cm step-proof heat insulationdamp-proof membrane15-20 reinforced concrete flooring25-30 cm gravel filloriginal soil

6 0006 0006 0006 0006 000

+0,90

+2,40

-0,20

+9,80

+11,30

+12,64

+0,90

+2,40

+0,90

+2,40

6 0006 0006 0006 0006 000

-0,20

+9,80

+11,30

+12,64

6 0006 0006 0006 0006 0005005 0005 000

+12,64

+2,80

+4,00

+7,00

+4,00

+7,00

+4,00

+7,00

6 000 6 000 6 000 6 000 6 000 500 5 000 5 000

-0,20

+3,30

+4,33

+11,30

+12,64

LEFTSIDE FACADE

RIGHTSIDE FACADE

3Vakolt lábazati fal, .................(...) szín

21

45

Lindab tetőpanel .................(...) szín

BACKSIDE FACADE

FRONT FACADE

Projekt neve: Rajz neve:

Készítette:

Ellenőrizte:

Méretarány:

Dátum:

2051 Biatorbágy, Állomás u. 1/aTel.: 06-23/531-100Fax.: 06-23/310-703Adószám: 10539260-2-13

Rajzszáma:

Referenciaszám:

Megrendelő:

2012. november

HomlokzatokLINDAB TORNACSARNOK

MINTAÉPÜLET 2.

2

1

4

3

2

Lindab PLX korcolt lemezfedés, .................(...) szín, Elite bevonat

31

2

2

Lindab falpanel.................(...) szín

Lindab Rainline 190/120 ereszcsatorna, .................(...) szín, Elite bevonat

4

4

55

6

5

Ablak szegélyezés, Lindab síklemez, .................(...) szín, Classic bevonat

67

Vakolt téglafalazat, .................(...) szín

T-2/IV.

7 7

7

1. Lindab roof panel signal blue (RAL 5010) colour

2. Lindab wall panel signal blue (RAL 5010) and white (RAL 9002) colour

3. Lindab Rainline 190/120 rain gutter, white (001) colour, Elite coating

4. Plastered plinth wall, grey

5. Plastered brick wall, grey

6. Lindab PLX standing seam sheet cladding, white (001) colour, Elite coating

7. Window flashing, Lindab steel sheets, interior white (078) Classic coating

Page 8: Lindab building solutions

Model hall no. 3 presents an example for hall equipped to a high level of standard in a spacious way. The 30-m wide and 48-m long sports hall of 1.440 m2, with flat roof and eaves height of ~12m is suitable to hold gym lessons of elementary schools or secondary educational institutions operating up to twentyfour classes. It is suited to accommodate more volleyball- and tennis-courts, two basketball-courts crossways and even handball- and indoor football-courts longways. The spacious interior allows temporary detachments, even 2 or 3 seperate practicable places. It is suitable for any kind of mass sports and leisure activities and also for organizing events.

At the longitudinal side a two-storey, lean-to roofed social block with a floor area of ~430 m2 is attached to the building, that serves the social functions at a perfect level. It is able to accommodate storage rooms, rooms for social needs (locker rooms, bathrooms, toilets, showers), medical rooms, offices, even negotiating and conference rooms. Thus the complete building is appropriate for mulitple, mulitfunctional purposes in an efficient and economical way.

Model hall no. 3

GYM HALL DIMENSIONS

Width (m) 30.0

Length (m) 48.0

Height of the eaves (m) 11.5

Roof pitch (°/%) 2°

Floo area 1.440.0

OFFICIAL COURT DIMENSIONS THE HALL CAN ACCOMMODATE

volleyball (9x18m) – 4 db handball (20x40m) – 1 db

tennis (10,97x23,77m) – 3 db futsal (20x40m) – 1 db

basketball (15x28m) – 2 db

HALL BUILDING STRUCTURE

Primary framingAnchored steel columns + steel truss-girder

Secondary framingLoad-bearing floor deck from Lindab high profile trapezoid sheet (LTP150)

Roof claddingSoft, warm-deck roof (water insulation, heat insulation, vapour barrier)

Wall cladding Brick wallwork

Roof drainage Internal gutter system

SERVICE BUILDING BLOCK ATTACHED TO THE HALL (OPTIONAL)

Place of attachment to hall longitudinal end

Width (m) 9.0

Length (m) 24.0

Height of the eaves (m) 8.0

Roof pitch (°/%) 10%

Floor area 216.0

FUNCTIONALITY OPTIONS FOR THE SERVICE SPACE

Windbreak room, entrance space

Toilet, shower

Store room, storage space Medical room

Changing rooms, lockers Offices, conference room

SPECTACULAR DRAWINGS

Please note: The model halls, buildings we present here are intended for inspiration, which can be used as a starting point for the builders’ own designs, as an aid.

Page 9: Lindab building solutions

Pm: 900

1 50

01

200

Pm: 9001

500

1 20

0Pm: 900

1 50

01

200

Pm: 900

1 50

01

200

Pm: 900

1 50

01

200

Pm: 900

1 50

01

200

Pm: 900

1 50

01

200

Pm: 900

1 50

01

200

Pm: 900

1 50

01

200

2 40

02

400

2 40

01

000

2 40

01

000

Pm

: 900 1 200

1 500

Pm

: 900 1 200

1 500

Pm

: 900 1 200

1 500

Pm

: 900 1 200

1 500

Pm: 6

000

1 5003 000

Pm: 6

000

1 5003 000

Pm: 6

000

1 5003 000

Pm: 6

000

1 5003 000

Pm: 6

000

1 5003 000

Pm: 6

000

1 5003 000

Pm: 6

000

1 5003 000

Pm: 6

000

1 5003 000

Pm: 6

000

1 5003 000

Pm: 6

000

1 5003 000

Pm: 6

000

1 5003 000

Pm: 6

000

1 5003 000

Pm: 6

000

1 5003 000

Pm: 6

000

1 5003 000

Pm: 6

000

1 5003 000

3 0003 000

Pm: 6 000

1 50

03

000

Pm: 6 000

1 50

03

000

Pm: 6 000

1 50

03

000

Pm: 6 000

1 50

03

000

Pm: 6 000

1 50

03

000

Pm: 6 000

1 50

03

000

Pm: 6 000

1 50

03

000

Pm: 6 000

1 50

03

000

Pm: 6 000

1 50

03

000

Pm: 6 000

1 50

03

000

Pm: 6 000

1 50

03

000

Pm: 6 000

1 50

03

000

Pm: 6 000

1 50

03

000

Pm: 6 000

1 50

03

000

Pm: 6 000

1 50

03

000

Pm: 6 000

1 50

03

000

Pm: 6 000

1 50

03

000

Pm: 6 000

1 50

03

000

Pm: 6 000

1 50

03

000

Pm: 6 000

1 50

03

000

Pm: 6 000

1 50

03

000

Pm: 6 000

1 50

03

000

Pm: 6 000

1 50

03

000

Pm: 6 000

1 50

03

000

Pm: 6

000

3 0001 500

Pm: 6

000

3 0001 500

Pm: 6

000

3 0001 500

Pm: 6

000

3 0001 500

Pm: 6

000

3 0001 500

Pm: 6

000

3 0001 500

Pm: 6

000

3 0001 500

Pm: 6

000

3 0001 500

Pm: 6

000

3 0001 500

Pm: 6

000

3 0001 500

Pm: 6

000

3 0001 500

Pm: 6

000

3 0001 500

Pm: 6

000

3 0001 500

Pm: 6

000

3 0001 500

Pm: 6

000

3 0001 500

Pm: 6 000

3 00

01

500

Pm: 6 000

3 00

01

500

Pm: 6 000

3 00

01

500

Pm: 6 000

3 00

01

500

Pm: 6 0003 00

01

500

Pm: 6 000

3 00

01

500

Pm: 6 000

3 00

01

500

Pm: 6 000

3 00

01

500

Pm: 6 000

3 00

01

500

Pm: 6 000

3 00

01

500

Pm: 6 000

3 00

01

500

Pm: 6 000

3 00

01

500

3 00

03

000

Pm: 9

00

1 5001 200

Pm: 9

00

1 5001 200

Pm: 9

00

1 5001 200

2 4001 000

6 000 6 000 6 000 6 000 6 000 6 000 6 000 6 000

48 000

9 50

030

000

39 5

00

750 1 500 1 500 1 500750 750

1 500 1 500 1 500750

7351 200

6501 200

6501 200

365500

1 000300

2 400300

1 000500

7351 200

6501 200

6501 200

365365

1 200650

1 200650

1 200735

750

1 500 1 500 1 500750 750

1 500 1 500 1 500 750

4 50

04

500

500

750

1 50

01

500

1 50

075

075

01

500

1 50

01

500

750

750

1 50

01

500

1 50

075

075

01

500

1 50

01

500

750

750

1 50

01

500

1 50

075

0

840

1 20

084

01

20042

0 4201

200

2 88

050

06

000

6 00

06

000

6 00

06

000

longitudinal bracing

longitudinal bracing

longitudinal bracing

longitudinal bracing

I. II. III. IV.

SERVICE BLOCK216 m2ceramic

B

SPORTS HALL1440 m2

sports flooring

B

C

D

VI. VII.V. VIII. IX.

A

B

TENNIS TENNISTENNIS

A

VOLLEYBALLVOLLEYBALL VOLLEYBALLVOLLEYBALL

BASKETBALL BASKETBALL

HANDBALL

AProjekt neve:

AlaprajzRajz neve:

Készítette:

Ellenőrizte:

Méretarány:

Dátum:

2051 Biatorbágy, Állomás u. 1/aTel.: 06-23/531-100Fax.: 06-23/310-703Adószám: 10539260-2-13

Rajzszáma:

Referenciaszám:

Megrendelő:

2012. november

LINDAB TORNACSARNOKMINTAÉPÜLET 3.

T-3/I.

5009 000

+2,80

+6,00

+9,00

30 000

+0,90

+2,40

+4,90

+6,40

-0,20

+12,30

6 0006 0006 0006 0006 0006 0006 0006 000

6 0006 0006 0006 0006 0006 0006 0006 000

500 9 000

+2,80

+6,00

+9,00

30 000

+0,90

+2,40

+4,90

+6,40

+6,00

+9,00

+6,00

+9,00

-0,20

+12,30

+2,80

+6,00

+9,00

+0,90

+2,40

+4,90

+6,40

-0,20

+12,30

-0,20

+12,30

5,71° = 10 %

5,71° = 10 %

1

BACKSIDE FACADE

LINDAB TORNACSARNOKMINTAÉPÜLET 3.

3

3

21

T-3/IV.

1

Projekt neve: Rajz neve:

Készítette:

Ellenőrizte:

Méretarány:

Dátum:

2051 Biatorbágy, Állomás u. 1/aTel.: 06-23/531-100Fax.: 06-23/310-703Adószám: 10539260-2-13

Rajzszáma:

Referenciaszám:

Megrendelő:

2012. november

Homlokzatok

1

2

FRONT FACADE RIGHTSIDE FACADE

LEFTSIDE FACADE

Vakolt téglafalazat .................(...) szín

Lindab Rainline 190/120 ereszcsatorna, .................(...) szín, Elite bevonat

Lindab PLX korcolt lemezfedés, .................(...) szín, Elite bevonat

1

1 11

1 20

011

500

30 000

-1,40-0,20

±0,00

+8,00

500 9 000

-1,40-0,20

±0,00

+11,30

+12,30

±0,00

5,71° = 10 %

2,0°

foundations (according to static specifications)

"LR" truss girder structure(according to static specifications)

1

5

(external dimensions of primary frame)

3

(ext

erna

l eav

es h

eigh

t of f

ram

e st

ruct

ure)

4

2

Projekt neve: Rajz neve:

Készítette:

Ellenőrizte:

Méretarány:

Dátum:

2051 Biatorbágy, Állomás u. 1/aTel.: 06-23/531-100Fax.: 06-23/310-703Adószám: 10539260-2-13

Rajzszáma:

Referenciaszám:

Megrendelő:

2012. november

A-A metszet T-3/II.LINDAB TORNACSARNOK

MINTAÉPÜLET 3.

ORDER OF LAYERS:

waterproof PVC membranestep-proof mineral wool heat insulation 16-20 cmvapour barrierLindab LTP 150 load-bearing floor deck profilesteel frame structure

1

heat insulated facade system 10 cmbrick wall 30 cm2

3 Lindab PLX standing seam roofingwooden boarding (2,4 cm)5x5 cm counter batten every 1 m with ventilated air spaceLindab LTP 20 trapezoid cladding (2 cm)LTF 180 breathable construction foilLindab Z 200 purlin system20 cm mineral wool heat insulation betweenLPZ 110 vapour barriergypsum plasterboard supporting frame (2 cm)2 ply gypsum plasterboard cladding (2,5 cm)

4 interior plaster (1 cm)hollow block brick wall (38 cm)facade heat insulation system (5 cm)exterior plaster (1,5 cm)

5 2-3 cm sport flloring8-10 cm floor slabPE technological membrane8-10 cm step-proof heat insulationdamp-proof membrane15-20 reinforced concrete flooring25-30 cm gravel filloriginal soil

6 0006 0006 0006 0006 0006 0006 0006 000

±0,00

+9,80

+11,30

-0,20

±0,00

+12,30

foundations (according to static specifications)

1

5

2

Projekt neve: Rajz neve:

Készítette:

Ellenőrizte:

Méretarány:

Dátum:

2051 Biatorbágy, Állomás u. 1/aTel.: 06-23/531-100Fax.: 06-23/310-703Adószám: 10539260-2-13

Rajzszáma:

Referenciaszám:

Megrendelő:

2012. november

LINDAB TORNACSARNOKMINTAÉPÜLET 3.

waterproof PVC membranestep-proof mineral wool heat insulation 16-20 cmvapour barrierLindab LTP 150 load-bearing floor deck profilesteel frame structure

1 heat insulated facade system 10 cmbrick wall 30 cm2

ORDER OF LAYERS:

B-B metszet T-3/III.

5 2-3 cm sport flloring8-10 cm floor slabPE technological membrane8-10 cm step-proof heat insulationdamp-proof membrane15-20 reinforced concrete flooring25-30 cm gravel filloriginal soil

GROUND PLAN

SECTIONS

ELEVATION

1.440 m2Possible application: elementary and secondary schools with 8, 16 an 24 classes

1. Plastered brick wall in colours of the spectacle

2. Lindab Rainline 190/120 rain gutter, dark grey (087) colour, Elite coating

3. Lindab PLX standing seam profile, dark grey (087) colour, Elite coating

1 20

011

500

30 000

-1,40-0,20

±0,00

+8,00

500 9 000

-1,40-0,20

±0,00

+11,30

+12,30

±0,00

5,71° = 10 %

2,0°

foundations (according to static specifications)

"LR" rácsos keretszerkezet(according to static specifications)

1

5

(external dimensions of primary frame)

3

(ext

erna

l eav

es h

eigh

t of f

ram

e st

ruct

ure)

4

2

Projekt neve: Rajz neve:

Készítette:

Ellenőrizte:

Méretarány:

Dátum:

2051 Biatorbágy, Állomás u. 1/aTel.: 06-23/531-100Fax.: 06-23/310-703Adószám: 10539260-2-13

Rajzszáma:

Referenciaszám:

Megrendelő:

2012. november

A-A metszet T-3/II.LINDAB TORNACSARNOK

MINTAÉPÜLET 3.

ORDER OF LAYERS:

waterproof PVC membranestep-proof mineral wool heat insulation 16-20 cmvapour barrierLindab LTP 150 load-bearing floor deck profilesteel frame structure

1

heat insulated facade system 10 cmbrick wall 30 cm2

3 Lindab PLX standing seam roofingwooden boarding (2,4 cm)5x5 cm counter batten every 1 m with ventilated air spaceLindab LTP 20 trapezoid cladding (2 cm)LTF 180 breathable construction foilLindab Z 200 purlin system20 cm mineral wool heat insulation betweenLPZ 110 vapour barriergypsum plasterboard supporting frame (2 cm)2 ply gypsum plasterboard cladding (2,5 cm)

4 interior plaster (1 cm)hollow block brick wall (38 cm)facade heat insulation system (5 cm)exterior plaster (1,5 cm)

5 2-3 cm sport flloring8-10 cm floor slabPE technological membrane8-10 cm step-proof heat insulationdamp-proof membrane15-20 reinforced concrete flooring25-30 cm gravel filloriginal soil

6 0006 0006 0006 0006 0006 0006 0006 000

±0,00

+9,80

+11,30

-0,20

±0,00

+12,30

foundations (according to static specifications)

1

5

2

Projekt neve: Rajz neve:

Készítette:

Ellenőrizte:

Méretarány:

Dátum:

2051 Biatorbágy, Állomás u. 1/aTel.: 06-23/531-100Fax.: 06-23/310-703Adószám: 10539260-2-13

Rajzszáma:

Referenciaszám:

Megrendelő:

2012. november

LINDAB TORNACSARNOKMINTAÉPÜLET 3.

waterproof PVC membranestep-proof mineral wool heat insulation 16-20 cmvapour barrierLindab LTP 150 load-bearing floor deck profilesteel frame structure

1 heat insulated facade system 10 cmbrick wall 30 cm2

ORDER OF LAYERS:

B-B metszet T-3/III.

5 2-3 cm sport flloring8-10 cm floor slabPE technological membrane8-10 cm step-proof heat insulationdamp-proof membrane15-20 reinforced concrete flooring25-30 cm gravel filloriginal soil

6 0006 0006 0006 0006 0006 0006 0006 000

±0,00

+9,80

+11,30

-0,20

±0,00

+12,30

foundations (according to static specifications)

1

5

2

Projekt neve: Rajz neve:

Készítette:

Ellenőrizte:

Méretarány:

Dátum:

2051 Biatorbágy, Állomás u. 1/aTel.: 06-23/531-100Fax.: 06-23/310-703Adószám: 10539260-2-13

Rajzszáma:

Referenciaszám:

Megrendelő:

2012. november

LINDAB TORNACSARNOKMINTAÉPÜLET 3.

waterproof PVC membranestep-proof mineral wool heat insulation 16-20 cmvapour barrierLindab LTP 150 load-bearing floor deck profilesteel frame structure

1 heat insulated facade system 10 cmbrick wall 30 cm2

ORDER OF LAYERS:

B-B metszet T-3/III.

5 2-3 cm sport flloring8-10 cm floor slabPE technological membrane8-10 cm step-proof heat insulationdamp-proof membrane15-20 reinforced concrete flooring25-30 cm gravel filloriginal soil

Page 10: Lindab building solutions

References

Lindab building solutions for gymnasiums and sports halls from the smallest to the largest!

Take a look at some of the realized sport institutions, gym halls, where the idea of a school, district or city got into shape with the application of Lindab products. It can be about a sportspace with 400-500m2 floorspace or even a hall with a floorspace of 10.000m2.Every unique idea and plan can be put into practice by Lindab products and systems according to the respective needs of a school, local government, sport institution or an investor.

Page 11: Lindab building solutions

Building: City sportcenreLocation: Sátoraljaújhely (Borsod-

Abaúj-Zemplén megye / HUNGARY)

Construction year: 2002Hall size: ~28x55m (~1540m2)Lindab products: Construline purlin- and wall-stud system, Coverline roof- and wall-cladding tra-peziodal profiles (LTP45, LVP20), Rainline rainwater system, flashings

Building: Angyalföldi Láng sporthall extension

Location: Budapest XIII. ker. / HUNGARY

Construction year: 2010Hall size: 20,4x46,2m

(~950m2)Lindab products: LTP150 load-

bearing trapezoid profiles (Coverline productgroup)

Building: City sportcentreLocation: Alsózsolca (Borsod-Abaúj-Zemplén megye / HUNGARY)Hall size: ~ 1 500 m2

Lindab products: Construline purlin and wall-stud system, Coverline roof- and wall-cladding trapezoidal profiles (LTP45, LVP20), Rainline rainwater system, flashings

Page 12: Lindab building solutions

Building: Gym hall of elementary schoolLocation: Nagyharsány (Baranya megye / HUNGARY)Construction year: 1994Hall size: ~800m2

Lindab products: Construline purlin- and wall-stud system, Topline tile effect roof cladding, Coverline external and internal wall cladding trapezoid profiles (LVP20), Rainline rainwater system, flashings

Building: Gym hall of elementary schoolLocation: Leányfalu (Pest megye / HUNGARY)Construction year: 2010Hall size: ~550m2

Lindab products: Construline purlin system, Coverline roof cladding trapezoid profile (LTP45), Rainline rainwater system, Protectline roof safety system (pipe snow guard), flashing

Building: Gym hall of elementary school, flat roof reconstruction

Location: Nagykovácsi (Pest megye / HUNGARY)

Construction year: 2011Hall size: 15x30m (~450m2)Lindab products: Coverline roof cladding trapezoid profile (LTP45), Rainline rainwater system, Protectline roof safety system (pipe snow guard), flashings

References

Page 13: Lindab building solutions

Building: Friends Arena (the stadium of AIK Stockholm club and Swedish national football team)

Location: Stockholm (Sweden)Construction year: 2009-2011Hall size: 68x105m courtsize

(7140m2), 50.000 seating capacity

Lindab products: Lindab high profile load-bearing trapezoid sheets (~22.000m2), special stainless self-drilling screws (~400.000pcs), Lindab Ventilation system (~17.000m total length)

Sporthall Vara, Sweden Floor area: 2 500 m2

Lindab products: Lindab trapezoid sheets

Page 14: Lindab building solutions

Building: Lindab Arena (Ice-hall) Ängelholm, SwedenSize: 3.000 seating capacity sports hallLindab products used: Lindab trapezoid sheets

Building: Icerink hall, SwedenFloor area: 2 500 m2

Lindab products used: Lindab trapezoid sheets

References

Building: Cluj Arena (The stadium of the Romanian footbal club, FC Universitatea Cluj)Location: Cluj, RomaniaConstruction year: 2009-2011Hall size: 68x105m courtsize (7140m2), ~30.500 seating capacityLindab products: Special sheet metal roof and wall cladding. Special multicoloured, opaled coating; unique, dual curvature standing seam roof cladding (~20.000m2) and wall cladding (~2000m2); perforated facade wall cassettes (~5000m2)

Page 15: Lindab building solutions

Technical aspects and parametersThe directives of the European Union concerning the construction industry set out the basic requirements for buildings. According to these aspects, we sum up here the options offered by Lindab’s product groups.

“Mechanical resistance and stability” – the design and construction of framing structures of compliant load-bearing capacity on the long run are ensured by the use of high-strength steel materials and optimized dimensions, as well as our self-developed structural dimensioning tools (charts, softwares).

“Safety in case of fire” – There are a number of laboratory tests, standard calculations and qualifications available as regards the fire-protection classes and performance parameters (fire-resistance limit values) under applicable European standards (EN) of Lindab products and systems. By the help of these tools, the required framing solutions or sheeting systems can always be specified for the requested fire safety level.

“Hygiene, health and the environment” – The materials of Lindab light gauge steel products, throughout their entire life span, do not contain components, which are harmful to human health or the environment. A men-tion must be made here that the steel raw material is recyclable, and the minimum quantities of wastes produced in the manufacture and construction works phase does not impose a burden to the environment.

“Safety of use” – In connection with this aspect it is worth mentioning that the durability of Lindab steel prod-ucts is ensured by a multi-layer coating system applied over a hot-dip galvanized surface that ensures corrosion protection.

“Protection against noise” – Two major areas should be distinguished in terms of acoustics: sound inhibition and sound absorption. For “sound inhibition” (where the task of the surface structural element in question is to ensure that the lowest possible part of a sound effect generated at one side should be detected at the other side), various Lindab assembled roof- and wall-cladding systems and pre-fabricated sandwich panels are available, with various test results, on the basis of which the required solution can be selected. Where “sound absorption” is prescribed (where the impact of a noise source located at one – generally the inner – side of the surface structure must be reduced for such „receivers” who are located at the same side of the surface structure in question), the application of perforated wall cladding sheets (pierced densely by small-size holes) offers an excellent solution.

“Energy economy and heat retention” – For buildings, on of the most important points of view today is the amount of energy they require for the purpose of use (heating and/or cooling, ventilation or other technologies), as this factor has a significant impact on operation costs. From among all the building structures, the thermal insulation capabilities of roof- and wall-claddings are the decisive parameters. The roof- and wall-cladding systems offered by Lindab provide a very wide choice also in terms of thermal insulation levels; the lightweight, thermal-insulated solu-tions are capable of meeting needs from a slightly tempered one to even a passive-building-level performance, with small spacings between the various solutions. The thermal insulation capability of building elements must always be specified individually, in a circumspect manner, based on relevant needs and prescriptions.

“Sustainable use of natural resources” – From this point of view it is important to emphasize that Lindab’s roofing systems (producing especially large areas in case of halls for instance) allow for an excellent opportunity for the use of the various solar systems being on the market (solar collectors for hot water or heating, or electricity generating solar cells). In the case of each different Lindab roof-cladding system (trapezoidal profiles, tile-effect roof sheets, sandwich panels or standing seam roof sheets), pre-engineered accessory system components are available for accommodating and fastening solar components on the roof safely (through load-bearing and watertight connections).

Product identification and certificates of conformityAs the realization process in the construction industry involves a number of players in most cases (design, production, sales, installation/construction works, general contracting, and organisation), it is of major importance to ensure the identification of makes and products, and the control of their technical conformity in every phase of a project. Identification of products at the building site is not always easy. For this end, the products manufactured by Lindab are marked by a videojet marking (product type, profile, serial number, date of production, etc.); while certain components are stamped in a raised print by the „Lindab” brand name (e.g. the joining ends of gutters), promoting a clear identification of Lindab products. Product identification is important also to ensure the assignment of products to quality documentations whose release is mandatory by law (ÉME, TMI, CE-mark, Declaration of Conformity).

Contact, quotations, informationIn specific questions related to hall systems, framing or sheeting elements, Lindab Kft.’s people are pleased to be available to your valued inquiry throughout the design, preparation, tendering (consignation, quotation-preparation) and the construction works phases.Please ask for our free professional consultation, and please do not hesitate to contact us with your special inquiries!

Budapest, Pest megye

Polgár Dávid 06 30 248-2391 [email protected]

Csongrád, southern part of Pest megye and Bács-Kiskun megye

Kelemen Kornél 06 30 708-6463 [email protected]

Veszprém, Vas, Fejér and Győr-M-S and Komárom-Esztergom

Móricz Gábor 06 30 708-6462 [email protected]

Zala and Somogy, Tolna and Baranya megye

Devecz Tamás 06 30 433-1603 [email protected]

Jász-Nagykun-Szolnok, Hajdú-Bihar and Békés megye

Kulcsár Viktor 06 30 433-2064 [email protected] Nógrád, Heves, Borsod-A-Z and Szabolcs-Szatmár-Bereg megye

Fülep Attila 06 30 433-1795 [email protected]

Design consultantMolnár István06 30 [email protected]

Engineering, structural and fire-safety questionsKotormán István06 30 [email protected]

Sales, quotationErőss Zoltán06 30 [email protected]

On-site project coordination, professional consultation and plans, design issues

Page 16: Lindab building solutions

2051 Biatorbágy, Állomás u. 1/A.Tel.: +36-23-531-300, Fax: +36-23-531-141

www.lindab.hu/csarnokwww.lindab.hu

Lindab Profil

fehér alapra

fehér alapra

színes alapra