Lindab solo - Simply the natural choice. Chilled beam r evolution!. Save up to 45 % cooling energy!* Installation and investment savings! Maintenance and running costs savings! Win – Win situation *Documented by SBI publication 2013 (Aalborg University, Denmark) . - PowerPoint PPT Presentation

TRANSCRIPT

Page 1: Lindab solo  - Simply the natural choice

Lindab solo - Simply the natural choice...

Page 2: Lindab solo  - Simply the natural choice

lindab | comfort

Chilled beam revolution!

+ Save up to 45 % cooling energy!*

+ Installation and investment savings!

+ Maintenance and running costs savings!

= Win – Win situation

*Documented by SBI publication 2013 (Aalborg University, Denmark)

Page 3: Lindab solo  - Simply the natural choice

lindab | comfort

Chilled beam revolution!• High temperature cooling and Low

temperature heating!

• No need for simultaneously running heating and cooling units ever again!

• No regulation equipment and pipe treatment- No regulation valves- No actuators- No room regulators- No sensors (e.g. presence & CO2)- No pipe insulation= Large installation savings!

• One set of pipes can be used for heating and cooling, at the same time!

Page 4: Lindab solo  - Simply the natural choice

lindab | comfort

Beam descriptionThe Lindab Solo beam

• Powerful chilled beam battery

• Great capacity at extreme low temperature heating and high temperature cooling

• Fixed spread pattern and factory preset air volume, for an easy and convenient solution

Example3,6 m Solo beam in a 25°C room Air = 25 l/s at 100 PaWater = 20°C in - 23°C outTotal cooling capacity = 744W

Page 5: Lindab solo  - Simply the natural choice

lindab | comfort

Temperature vs. loadsExpected indoor temperature

• The water flow is constant• Outdoor temperature will dictate inlet temperature• Difference in external/internal loads will affect room temperature

• Summer:Internal + external load = +600WRoom temperature = 24,4°C

• Spring/Autumn:Internal + external load = -230WRoom temperature = 20°C

• Winter:Internal + external load = -400WRoom temperature = 20°C

Capacity per beam, 3,0m [W]

Room temperature [°C]

Summer

Spring/Autumn

Winter

Page 6: Lindab solo  - Simply the natural choice

lindab | comfort

System description – Spring and Autumn

• Needed inlet temperature reached fully or partially by mixing the return water .

• Allows for fully or partially shut down of heating and cooling units

• Savings of up to 5 % on total energy usage (without free cooling).

• Either the heating or cooling unit needs to be running. But not both at the same time.

• Should assistance from the cooling unit be necessary, free cooling should be obtainable through part of the season.

North facadeHeating demand

South facadeCooling demand

High Temperature Cooling (HTC) and Low Temperature Heating (LTH)

Page 7: Lindab solo  - Simply the natural choice

lindab | comfort

System description - SummerHigh Temperature Cooling (HTC)

• Cooling supplied via beams running relatively high temperature water

• Possible due to the optimized high output battery, unique the Solo beam.

• Offers great possibilities for free cooling

• 25 % better COP from cooling units

• Extremely low risk of condensation, due to the high inlet temperature.

• As heating demands may occur during Summer in some regions, even higher savings can be expected

North facadeCooling demand

South facadeCooling demand

Page 8: Lindab solo  - Simply the natural choice

lindab | comfort

System description - WinterLowTemperature Heating (LTH)

• Lower water temperatures compared to conventional radiator or chill beam systems.

• Possible due to the optimized high output battery, unique to the Solo beam.

• Smaller risk of heat loss from pipes, as running temperature is close to room temperature.

• Eliminate problems with draft, due to near-isothermal inlet temperatures.

• Low temperature stratification in the occupied zone results in a better mix of room and inlet air.

North facadeHeating demand

South facadeHeating demand

Page 9: Lindab solo  - Simply the natural choice

lindab | comfort

Temperature gradientLindab Solo Normal chilled beam

18 19 20 21 22 23 240

0.5

1

1.5

2

2.5

3

18 19 20 21 22 23 240

0.5

1

1.5

2

2.5

3

Cei

ling

heig

ht [m

]

Temperature [C°]

Cei

ling

heig

ht [m

]

Temperature [C°]

Page 10: Lindab solo  - Simply the natural choice

lindab | comfort

Free cooling solution Optimize free cooling opportunities

• Free cooling overview:1: Free cooling ON/OFF (Optimized) – Save 32% energy2: Free cooling MODULATING (Optimized) – Save 45% energy

  Scenario No.1 2

  Free cooling (%) Outdoor Temperature [°C]

Conventional Chilled beam

100 ≤10 ≤1075 - 10-1150 - 11-1225 - 12-13

SOLO

100 ≤16 ≤1675 - 16-1750 - 17-1825 - 18-19

Scenario 1 Scenario 20

2

4

6

8

10

12

14

16

15.03 14.47

10.2

7.94

Annual Cooling Energy Demand [kWh/m²]

Conventional Chilled beamSOLO

Page 11: Lindab solo  - Simply the natural choice

lindab | comfort

Better COP performance

• Cooling & Heating unit performanceHigher cooling temperatures in the Solo system, allows for a more efficient use of heat pumps.

• Coefficient Of Performance (COP)The Δt between the outdoor temperature and the inlet water temperature in cooling scenarios will normally be at least 5°C lower on the Solo solution than on conventional systems.

The COP value of the heat pump can therefore be expected to be over 25% higher than in a conventional system.

The Δt value in heating scenarios is even better, giving even larger savings when using a heat pump for both cooling and heating.

Optimized cooling and heating performance

Page 12: Lindab solo  - Simply the natural choice

lindab | comfort

Renewable energySolo – optimizing substainable energy usage

• Low heating water temperatures optimal for solar panels.

• Geothermal heating, heat pumps and other low temperature energy sources are suitable as well.

Page 13: Lindab solo  - Simply the natural choice

lindab | comfort

Installation and investment savings

• Installation timeA simple solution enables a quicker installation, providing further savings

• Overall savingsThe simplicity of the Solo system means less accessories. Which in turn means huge savings, especially as radiators are not needed.

Savings, on several aspects

Page 14: Lindab solo  - Simply the natural choice

lindab | comfort

Maintenance and running costs savings

• Cooling energy consumptionLower running times on cooling units, plus the use of free cooling, provides a huge saving potential.

• MaintenanceLess components gives a much lower maintenance cost.

Future savings

Page 15: Lindab solo  - Simply the natural choice

lindab | comfort

Heating and Cooling sourcesPoints of interest

• Heat pumps• Better COP, due to

temperature set• Applicable for both heating and

cooling

• District heating from heat plant• Lower running temperatures

on the Solo system offers a lower return temperature to the heat plant

• District cooling from cooling plant• New way of cooling• Applicable to Lindab Solo

• Free cooling• Better gain, and longer

season, due to temperature set

• Both heating and cooling

• Solar panels• Low inlet temperature for

heating, enables the full use of solar panels in spring/autumn.

Page 16: Lindab solo  - Simply the natural choice

lindab | comfort

SummaryNo regulation valves, actuators etc.Continuously running system = No need for regulation on individual beams.No need of pipe Insulation, neither on ducts.

Free coolingHigh Temperature Cooling results in optimal conditions for free cooling.

No radiators or pipes for heatingHeating is delivered by the Solo system =No need for radiators and associative piping

Recycled energy useSOLO is keeping the thermal energy in the building, instead of supplying and redrawing energy

Better COP performanceThe cooling water temperature in SOLO is at least 5 degrees higher compared to conventional chilled beam systems =Increased COP of >25% for the cooling unit(Higher COP for heating unit as well)

Renewable energyThe SOLO system allows a much better energy efficiency when using sustainable energy sources.