m-cti induced draft, cell type, grp cooling tower mnk-maxi ... · m-cti induced draft, cell type,...

2
Rudolf-Diesel-Straße 17-25 46485 Wesel · Germany Tel. +49 (0) 281 337474-00 Fax +49 (0) 281 337474-99 [email protected] www.m-cti.com M-CTI induced draft, cell type, GRP cooling tower MNK-MAXI series Based on our 25 years of experience in cooling tower design, our previous involvement in planning and supply of structural built cooling towers, we have extended and completed our MNK- SMALL and MNK-MIDI series with the MNK-MAXI series. Previously, on cooling towers with a per- formance beyond the MNK-SMALL and MIDI series, we applied either timber or concrete structures. As a result of research and develop- ment, we developed our own GRP struc- tured cooling tower design. For owner and operator, a long and cor- rosion free operation is guaranteed. Because of this development, we suc- ceeded in reducing the erection period considerably in case of cooling tower replacement, using the already existing basin. The new cooling tower is to be erected adjacent to the cooling tower to be de- molished, and than lifted by heavy cra- nage on the existing basin. This procedure provides a considerably reduced shut down period for the ow- ner. SERIES DESCRIPTION: The cell’s foot print of the MNK-MAXI series depends on whether the concrete basin exits or is to be designed. MATERIALS: • GRP structure • stainless steel hardware • GRP cladding • anti slip GRP fan deck • GRP railing • GRP stairway and cage ladder • PP drift eliminators • flanged PP water distribution • efficient in fill in PP or PVC FAN GROUP: • induced draft fans with aluminium or GRP blades • diffusors and fan stacks in GRP with stainless steel hardware • double helical, oil lubricated right angle gearboxes • free floating composite shaft with stainless steel couplings between motor and gearbox. • e-motor in proper enclosures, suitable for cooling towers ADVANTAGES • no corrosion • rigid construction • shorter erection period • shorter delivery times • minimal shut down periods • continuous operation of process (in case of multiple cell replacement) • minimal costs Subject to technical revisions Certifications:

Upload: others

Post on 26-Jun-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: M-CTI induced draft, cell type, GRP cooling tower MNK-MAXI ... · M-CTI induced draft, cell type, GRP cooling tower MNK-MAXI series Based on our 25 years of experience in cooling

Rudolf-Diesel-Straße 17-2546485 Wesel · GermanyTel. +49 (0) 281 337474-00Fax +49 (0) 281 [email protected]

M-CTI induced draft, cell type, GRP cooling tower MNK-MAXI series

Based on our 25 years of experience in cooling tower design, our previous involvement in planning and supply of structural built cooling towers, we have extended and completed our MNK- SMALL and MNK-MIDI series with the MNK-MAXI series.

Previously, on cooling towers with a per-formance beyond the MNK-SMALL and MIDI series, we applied either timber or concrete structures.

As a result of research and develop-ment, we developed our own GRP struc-tured cooling tower design.

For owner and operator, a long and cor-rosion free operation is guaranteed.

Because of this development, we suc-ceeded in reducing the erection period considerably in case of cooling tower replacement, using the already existing basin.

The new cooling tower is to be erected adjacent to the cooling tower to be de-molished, and than lifted by heavy cra-nage on the existing basin.

This procedure provides a considerably reduced shut down period for the ow-ner.

SERIES DESCRIPTION:

The cell’s foot print of the MNK-MAXI series depends on whether the concrete basin exits or is to be designed.

MATERIALS:• GRP structure• stainless steel hardware• GRP cladding• anti slip GRP fan deck• GRP railing• GRP stairway and cage ladder• PP drift eliminators• flanged PP water distribution• efficient in fill in PP or PVC

FAN GROUP:• induced draft fans with aluminium or

GRP blades• diffusors and fan stacks in GRP with

stainless steel hardware• double helical, oil lubricated right

angle gearboxes

• free floating composite shaft with stainless steel couplings between motor and gearbox.• e-motor in proper enclosures, suitable for cooling towers

ADVANTAGES• no corrosion• rigid construction• shorter erection period• shorter delivery times• minimal shut down periods• continuous operation of process (in

case of multiple cell replacement)• minimal costs

Subject to technical revisions

Certifications:

Page 2: M-CTI induced draft, cell type, GRP cooling tower MNK-MAXI ... · M-CTI induced draft, cell type, GRP cooling tower MNK-MAXI series Based on our 25 years of experience in cooling

Rudolf-Diesel-Straße 17-2546485 Wesel · GermanyTel. +49 (0) 281 337474-00Fax +49 (0) 281 [email protected]

640 8001000120014401680196022402560

8000 800010000100001200012000140001400016000

80001000010000120001200014000140001600016000

560056006000600068006800680075007500

2600/22600/23000/23000/23800/23800/23800/24500/24500/2

7500 7600 8100 8300 9100 9500 97001050010700

4870 5545 6090 6700 7310 7920 8530 914010360

117001180012300125001330013700139001470014900

400 - 1800 500 - 2200 600 - 2600 700 - 3200 800 - 4100 900 - 48001000 - 56001100 - 66001200 - 7400

M-CTI induced draft, cell type, GRP cooling tower MNK-Maxi series

Subject to technical revisions

Certifications:

TECHNICAL DATA:MNK Length

inmm

Widthin

mm

Height in

mm

Height inlet in mm

and number

Height fan deck in mm

Diameterfan

in mm

Total heightincl. stack

in mmmax.

Water flowin m³/h