  • 8/11/2019 M.calculo Tapa 1406-02-500GL

    1/1

    2

    3

    4

    6

    7

    8 Dimens ions : 9 37.441 951 mm Do [in] - Dimetro exterior de la tapa10 18.720 475.5 mm L [in] - Radio interior curva (nota 1)11 1.969 50 mm IKR [in] - radio interior menor (nota 2)12 0.118 3 mm tb [in] - espesor despues de conformado13 0.118 3 mm tf [in] - espesor antes de conformado (nota 3)14 0.039 1 mm Corr [in] - factor de corrosion15 1.772 45 mm Skirt [in] - longitud pestaa

    16 Condicio nes del Material: 17 A-36 Material18 16,600 S [psi] - Esfuerzo

    19 0.85 E - Eficiencia long. Tapa20 25.0 P [psi] - Presin interior 21 Calculo Propiedades: 22 nota 1: Radio sugerido L por UG-32(j) 37.44 Peso Aprox. Tapa basado en Acero, lbs = 90.2223 nota 2: Radio sugerido IKR por UG-32(j) 2.246 Volumen Aprox. Tapa incluyendo pestaa, cuft = 7.8124 nota 3: Espesor sugerido antes conformado 0.0861

    25 Variables: 26 nt [in] = tf-Corr ~~ thickness with corrosion allowance removed 0.118-0.039 = 0.07927 D [in] = Do-2*nt ~~ ID with corrosion allowance removed 37.441-2*0.079 = 37.28328 L/r = L/IKR 18.72/1.969 = 9.51029 M = 0.25*(3+sqrt(L/IKR)) 0.25*(3+SQRT(18.72/1.969)) = 1.52130 Ro [in] = L+tb 18.72+0.118 = 18.839

    31 Espesor Requerido: App. 1-4(a), App. 1-4(d)32

    App1-4(f) = tf/L 0.118/18.72 = 0.00633 App1-4(f)Calc =34 App. 1-4(f) Calculation Not Required35 T.req [in] =36 0.06537 Verif. Esp.T req = Treq= 25 = Acceptable

    42 App. 1-4(f) calculation is not included on this sheet43 Nozzles may be subject to a smaller required thickness depending on location in the head.44 Only the knuckle required thickness is calculated on this sheet

    45 Heads may be subject to stress relief if large elongation occurs - UCS-79(d), UNF-79(d), UG-37(a)(1)46 The UG-16(b) minimum thickness requirement has not been taken into consideration here. Fecha: jun-1447 This sheet cannot be used to check for allowable exterior pressure loads. Revisado por: Roberto A anca48 Use the Weld Efficiency program to calculate E49 This sheet is for educational use only - use at your own risk.

    50

    51

    52

    53

    (2*16600*0.85*0.079)/(18.72*1.521+0.2*0.079) =

    TELEFONO: 4519450

    Descripcin: Tanque Cilindrico 500 GLS Serie N 1406-02/500 GlCALCULO TAPA TORIESFERICA

    CELULAR: 996954934 RPM: *367867Punta Pescadores L-15 (Calle los Ferroles) Zona Industrial del Callao

    if(AND(0.0005=