Meduim Voltage Drives
Yantra-Harvest, a winning partnership of experience, technology and achievements in the Indian automation industry, now introduce
HARSVERT-A, the new generation VFD from Yantra - Harvest which is a multi-cell VFD with series-connect units, high
voltage input and output.
Beijing Leader & Harvest
Electric Technologies co. Ltd is a high-technology company specializing in the R&D, manufacture, sales and service of medium voltage variable frequency system. Today, Beijing Leader is a market leader in the manufacture of VFDs in China, having catapulted to
great heights within a short span of 5 years. They are an ISO 9001:2000 company, with a spectacular sales record to their credit. With a manufacturing unit in the Changping Yangfang Industrial Area of Beijing Leader & Harvest has always endeavored to meet the growing need of users and foster technological
advance. Beijing Leader & Harvest
has installed more than 3000 MV
Drives which are working
satisfactorily in various industry
segments.
Introduction
YANTRA HARVEST
LEADER & HARVEST has tirelessly endeavored to develop the medium voltage variable frequency drive (VFD) with high technology for years, meeting many challenges and quality demands in China. The products have passed the demanding test and inspection of the National Electrical Control Distribution Equipment Quality Supervision Inspection Center and the China Electric Power Research Institute as well as the product appraisal of the State Bureau of Machine Building Industry to obtain the Appraisal and Approval Certificate of New Product and New Technology granted by the State Economic and Trade Commission. LEADER & HARVEST relies on the first class technology foundation of a State Key Laboratory (Tsinghua University) and its experienced R & D team that continuously focuses on innovation and high quality. Their technical know-how and diligence has resulted in high-tech products, and after exploring market demands they have teamed up with production to introduce newer and better products.
Yantra primary technical services include automation and electrical engineering design, systems analysis, testing and support, systems integration, field service and commissioning, control, monitoring, testing and repair, with expertise in industries like:
Capabilities
• Oil and Gas
• Chemical and Petro-chemical Plants
• Automotive Plants
• Steel Plants
• Nylon and Tyre cord Plants
• Water and Effluent Treatment
• Power Generation and Utilities
• Pulp and Paper
• Pharmaceutical Industries
• Food and Beverages
• Textile
• Consumer ProductsYantra is India's first company to have executed the largest MV Drive projects in India for MRPL and HPCL.
Harnessing power, harvesting profits
YANTRA HARVEST
Application of
HARSVERT-A medium
voltage VFD series
Power generation:
Metal:
Petrochemical and chemical:
City construction:
Mining:
Paper & Pulp:
======
====
==
==
== =
==
Boiler feed PumpsCondenser water pump, I D Fans F D Fans P A FansCW Pump
Dusting Fans, Furnace Fans Descaling PumpsConverter ID Fans
Oil Transfer Pumps Compressors
Water-supply Pump Compressors
Mortar Pumps Fans / Blower Conveyer
I D Fans P A Fans
In the above industries, the application of the HARSVERT-A medium voltage VFD series achieves smooth speed and flux control, which saves vast energy compared with the control of using the traditional wind shields o r v a l v e s . U n d e r c e r t a i n c i r c u m s t a n c e s , u s e r s ' technological need is the reason of changing the speed of the fans and pumps. The HARSVERT-A medium voltage VFD series have r e m a r k a b l y h i g h c o n t r o l accuracy, which can completely s a t i s f y t h e t e c h n o l o g i c a l requirements.
Fig. A :System structure of 3.3kV series VFD Fig. B : System structure of 6.6 kV series VFDFig. C : System structure of 11kV series VFD
Fig. E : The PWM Step Wave of the Output phase voltage of High-Voltage inverter System
System PrincipleSystem StructureThe structure of HARSVERT-A series medium
voltage VFD is shown in fig A The system is composed of phase shifting transformer, power cells and controller. The 3300V series have 12 power cells, and every 4 cells make
Output Side StructureSee fig A and fig B At the output side, each cell's U and V output terminals are connected in series to form a star connection to supply power to the motor. By overlapping each cell's PWM wave, we can get the multilevel SPWM
waveform shown in fig E It has a excellent sine-shape, small dv/dt, no cable and motor insulation destruction, no output filter for long output cable, no motor derating, and can be used in driving the old motor directly. Meanwhile the motor harmonic is reduced greatly, the mechanical vibration is eliminated, and the
Power Cell Structure of HARSVERT-A
Medium Voltage VFD
Input Side Structure
The power cells are completely identical in structure, and can be replaced with each other. The circuit structure is shown in fig 3.2, it is a basic three phase input, single phase output AC-DC-AC VFD circuit. The rectifier is a three-phase diode bridge. Controlling the IGBT inverter By sinwave PWM, the output voltage waveform is shown in fig 3.3.
The phase shifting transformer supplies power to each power cell on the input side. The transformer's secondaries are divided into three groups; for 3300V series, 24-pulse rectifier mode is formed; for 6600V series, 36-pulse rectifier mode is formed; for 11000V series, 48-pulse rectifier mode is formed. This multi-pulse
R
S
T
A+
-A
V
UK
B+
up a phase in series. The 6600V series have 18 power cells, every 6 cells make up a phase in series. The 11000V series have 27 power cells, and every 9 cells make up a phase in series. The structures of 3300V, 6600V and 11000V series
VFDs are shown in fig A, B and C.
mechanical stress of shaft and vanes is reduced.When a certain power cell has a fault, by
automatically closing the relay K shown in fig C, the fault cell can be bypassed out without effect on other cells and-the VFD can run at a derated mode; so the loss due to the motor's suddenly shutting down can be reduced in many situations.
overlap rectifier mode greatly improves the line current waveform quality, and the load power factor can be improved up to near 1.In addition, the independence of the transformer's secondaries makes the power cell’s main circuit relatively separate, It's similar to the normal low-voltage VFD, therefore, easy to utilize the mature technologies
The fundamentals
YANTRA HARVEST
Cell Bypass (Optional)Harsvert-A Drive has a cell bypass feature which makes the Drive "N-1" redundant.
Integral Transformer
isolation transformer for easy, low cost, installation.
Factory wired integral
Easy to use Operator InterfaceInterface Terminal Membrane keypad includes function keys, cursor selection key for menu navigation, item selection and data entry.Standard operator device cluster includes, start, stop, and emergency stop pushbuttons, local/remote selector switch and local speed potentiometer.
Compatible with Standard Motors without Derating
Motor-friendly waveforms have
been the trademark of Harsvert
Drive with near sinusoidal output
current and voltage waveforms at
all speeds and loads. Standard
induction or synchronous motors
are compatible without derating.
Inverter duty motors are not
required.
Building intelligence at every step
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
Voltage source VFD, direct input of 3.3,4.16, 6.6, 11 kV, direct output of 3.3, 4.16, 6.6,
11 kV, no output transformer necessary.
High efficiency.
High input power factor, no power factor correction devices.
Low input harmonic current, full accordance with IEEE 519-1992, no input harmonic filters required.
Sinusoidal multi-level PWM output wavefrom, no output harmonic filters required, directly
connected to the shafts or the vanes, allowing the maximal length of the output cable of 1000m.
Friendly Human-Machine interface, easy to operate.
Modular design of the power circuits simplifies maintenance routine.
Medium voltage circuits are connected with controller by the optical fibers, which keep the
controller safe and away from the disturbance.
Complete fault monitor functions, accurate fault alarm and protection.
Integrated cooling blower.
The control logic can be conveniently changed in the integrated PLC.
Offer both field control and remote control in monitor station.
Support most of the industrial standard protocois. (Profibus, Modbus, TCP/IP etc.)
Compatible with industrial standard signal of 0-10V/4-20mA.
Open loop or closed loop operation with the integrated PID regulator.
Complete system parameter set-up function of VFD.
Easy installation.
Excellent performance/ price ratio.
Rated Output Capacity 250 - 6250 kVA
Applicable Motor Output 200 - 5000 kW
Output Cell cascaded, Multi-level SPWM output
Rated output Current < 600 A
Rated input and output Voltage 3300 - 11000 V 10%
Input Frequency Tolerance 45 - 55Hz
Input Power Factor 0.95 (>20% of full load)
System Efficiency > 0.96 (full load, including the input transformer)
Output Frequency Scope 0.5 Hz - 120 Hz
Output Frequency Resolution 0.01 Hz
Overload Endurance 120% of rated current for 1 minute; 150% immediately
Analogue Input Four channels, 0 - 10 V or 4 - 20 mA, more channels
available
Accel/ Decel Time 0.1 - 3000 sec. adjustable (load dependent)
Logical Control Input/Output Signals Expandable by user's need
Ambient Temperature 0 - 40 C
Storage/Ttransportation Temperature -40 - 70 C
Cooling Methods Air cooling or closed loop liquid cooling
(Liquid to Air/Liquid heat exchanger available)
Ambient Humidity < 90%, no condensation
Altitude Maximum 1000 m above MSL; higher available
Enclosure IP20, IP21, IP31
Size (WxHxD) 3300 - 10600 mm x 2480 mm x 1300 mm
Weight 3000 - 19000 Kg
Qualify Assurance ISO 9001:2000
0 0 0(45 C & 50 C available on demand)
0
Qualities that make HARSVERT-A VFD unique
Standard Specifications of HARSVERT-A VFD series