model h-3553 · model h-3553 bubbler/pressure sensor the waterlog® model h-3553 is a combined...

2
Design Analysis Associates Inc. • 75 West 100 South Logan, Utah 84321 USA • Tel: (435) 753-2212 • Fax: (435) 753-7669 • [email protected] • www.waterlog.com MoDeL H-3553 Bubbler/Pressure Sensor The WaterLoG ® Model H-3553 is a combined Bubbler with built in Pressure Sensor. The Pressure sensor is a NIST traceable pressure sensor. The sensor directly measures dry gas with accuracy better than 0.02% FSo. Combining high accuracy and low cost. The H-3553 provides the highest purge pressure in the industry at 90 psi. KeY FeATUReS • A complete single unit replacement for gas purge bubbler systems that includes the pressure sensor. • Measures depths up to 115 ſt (50 psi, 35m) • Pressure accuracy is 0.02% full scale • Accuracy over temperature range exceeds ±0.01 ſt. (3mm) of water • Built-in temperature compensation • Operating temperature range -40° to +60° C • Easy to use Simple RS-232 Menu Interface • SDI-12 output provides measurement data in programmable units such as feet, inches, meters, millimeters, centimeters, and user defined • Output modes: SDI-12, 4-20mA, and RS-232 • Compatible with RS-232 Data Logger • Enclosure is nonconductive and corrosion proof • Low current operation (6mA standby) • Extended SDI-12 command for setting the stage to the current water elevation or pressure • Up to 90 psi purge pressure • Unique purge sustain option • Atmospheric Pressure Compensated

Upload: others

Post on 12-Sep-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: MoDeL H-3553 · MoDeL H-3553 Bubbler/Pressure Sensor The WaterLoG® Model H-3553 is a combined Bubbler with built in Pressure Sensor. The Pressure sensor is a NIST traceable pressure

Design Analysis Associates Inc. • 75 West 100 South Logan, Utah 84321 USA • Tel: (435) 753-2212 • Fax: (435) 753-7669 • [email protected] • www.waterlog.com

MoDeL H-3553Bubbler/Pressure Sensor

The WaterLoG® Model H-3553 is a combined Bubbler with built in Pressure Sensor. The Pressure sensor is a NIST traceable pressure sensor. The sensor directly measures dry gas with accuracy better than 0.02% FSo.

Combining high accuracy and low cost. The H-3553 provides the highest purge pressure in the industry at 90 psi.

KeY FeATUReS• Acompletesingleunitreplacementforgaspurgebubblersystemsthatincludesthepressuresensor.

• Measuresdepthsupto115ft(50psi,35m)• Pressureaccuracyis0.02%fullscale• Accuracyovertemperaturerangeexceeds±0.01ft.(3mm)ofwater• Built-intemperaturecompensation• Operatingtemperaturerange-40°to+60°C• EasytouseSimpleRS-232MenuInterface• SDI-12outputprovidesmeasurementdatainprogrammableunitssuchasfeet,inches,meters,millimeters,centimeters,anduserdefined

• Outputmodes:SDI-12,4-20mA,andRS-232• CompatiblewithRS-232DataLogger• Enclosureisnonconductiveandcorrosionproof• Lowcurrentoperation(6mAstandby)•ExtendedSDI-12commandforsettingthestagetothecurrentwaterelevationorpressure

•Upto90psipurgepressure•Uniquepurgesustainoption•AtmosphericPressureCompensated

Page 2: MoDeL H-3553 · MoDeL H-3553 Bubbler/Pressure Sensor The WaterLoG® Model H-3553 is a combined Bubbler with built in Pressure Sensor. The Pressure sensor is a NIST traceable pressure

Design Analysis Associates Inc. • 75 West 100 South Logan, Utah 84321 USA • Tel: (435) 753-2212 • Fax: (435) 753-7669 • [email protected] • www.waterlog.com

Specifications

PeRFoRMANCeAccuracy (Maximum percent of error in measure-ment)

Pressure Lessthanorequalto0.02%offullscaleoutput(FSO)overtemperaturerangereferencedtoastraightlinestretchedfromzeroPSItomaximumpressure

Temperature Internaltemperature±1°Covertem-peraturerange

Resolution(Smallest change detectable in output signal)

Pressure 1partin1,000,000(0.0001%)

Temperature 1partin1,000,000(0.0001%)

Linearity Lessthan0.02%deviationfromastraightlinereferencedtoendpoints

Pressure Hysteresis

Lessthan0.01%ofFSO

Long-term Stability

Accuracydriftislessthan±0.05%ofFSOperyear

StandardPressureRanges:Customcalibrationrangesavailablefrom5-100PSI

Pressure Depth Accuracy

0to15PSI 0to34.6ft.(10.54m) ±0.007ft.(2.1mm)

0to30PSI 0to69.20ft(21m) ±0.014ft.(4.26mm)

50psialsoavailableInterfacrfacrface

INTeRFACeSDI-12 Protocol SDI-12V1.3,7-bitevenparity,1stopbit

BaudRate 1200Minimumhighlevel

3.5volts

Maximumlowlevel

0.8volts

ResponseTime 8-secondmeasurementsequence(programmable)

RS-232 Protocol RS-232,8-bit,noparity,1stopbit

BaudRate 9600

RS-485 Protocol ModbusRTU/H-355ControlBaudRate Programmable(default=9600)

4-20mA Output

Type 4-20mA,opticallyisolatedLoopVoltage 8.0Vmin,35VmaxResolution 16bitresolution+-0.24uA(16-bitDAC)Accuracy +-10uA

MeCHANICAL DATAMechanical Material Fiberglass

Size 9”widex10.5”longx6.3”high22.86cmwidex26.67cmlongx16cmhigh

Weight 9.5lbs(4.3kg)Rating NEMA4enclosureConnectors SealedBendixtypecircularPressureInlet 1/8”femaleNPTAtmosphericVent Sinteredbronze,#10-32

Power (requirements)

InputVoltage 10.0to16.5VoltsDC

SupplyCurrent SleepMode6mAActive(measuring/Purging):<20mAbasedona60bubbles/minuteflowratewitha15minutemeasurementcycleanda1purgeperdayfrequency.

SurgeProtection 20VDC

BubblerGas Delivery

Particulars MicroprocessorcontrolledunitGasFlowTechnology

ConstantmassTechnology

GasFlowControl Bubblerateisuserselectablefrom30to120bubblesperminutebasedon1/4in.tubingorificepointingdown.Autozeroerrorcontrolledflownozzle

Compressor Type PistonCompressor

Operation Lowdutycycle(7hourstypicalruntimeperyearat60bubblesperminuteflowrateinto12ft.ofstage-purgesnotincluded)

Purge Functions

PurgePressureLevel

UserSelectable30psito90psi

Options •Manual•SDIDrivenPurge•Purgesustainoption(10-240S)

Connections 7-pincircular Power,SDI-12,4-20mAandRS-4853-pincircular RS-232DataandMenuSetupPortCables MainConnectorcablewith6-ftpigtailis

provided.RS-232Connectorcableoptional

eNvIRoNMeNTTemperature Operating

Temperature-40°to60°C

CompensatedRange

-40°to60°C

StorageTemperature

-60°to80°C

MISCeLLANeoUSWarranty TheWaterLOG®H-3553iswarrantedagainstdefectsin

materialsandworkmanshipforoneyearfromdateofship-ment.

Note Specificationssubjecttochangewithoutpriornoticeduetoongoingcommitmenttoproducttestingandimprovement.LRJanuary15,2011.D250311.