n tio cu trsanpl o r ce fo pl t m o sa n

8
R e v i s i o n s : SAMPLE PLANS NOT FOR CONSTRUCTION D a t e : S h e e t : T i t l e : 1. NOT FOR CONSTRUCTION 2. 3. 4. 5. 6. 7. COVER SHEET A.0 A.9: Building Sections A.10: Framing Plan A.11: Shear Wall Details A.12: Framing Details A.13: Framing Details GreenLeaf Designs Tulsa, OK 918-524-9721 GreenLeafArchitecture.com S t a m p : DESIGN CRITERIA CODE: 2012 International Residential Code (2012 IRC) BUILDING TYPE: Light Framed Wood, Single-Family Residential Structure LOADS: Dead Loads: Roof- 22 PSF Floor- 32 PSF Live Loads: Roof- 20 PSF First Floor & Stairs- 100 PSF Snow Loads: Ground Snow Load (Pg)- 15 PSF Roof Snow Load (Ps)- 15 PSF Snow Roof Slope Factor (Cs)- 1.0 Importance Factor (Is)- 1.0 Wind Loads: (ASCE 7-05) Basic Wind Speed (3 sec gusts)- 100 MPH Exposure- C Importance Factor (Iw)- 1.0 Seismic Load: (ASCE 7-05) Importance Factor (Ie)- 1.0 Seismic Use Group- II - Normal Seismic Soil Profile Type- D Seismic Design Category- B Basic Seismic Force Resisting System- Light Framed Walls w/ Shear Panels Seismic Response Modification Factor (R)- 6.5 Analysis Procedure Used- Equivalent Lateral Force Soils: Undisturbed Earth- 2,500 PSI Bedrock- 25,000 PSI FIRE SPRINKLER: No FIRE ALARM SYSTEM: Yes GENERAL NOTES Drawings are intended to be printed on 24"x36" (Arch D) paper. Printing these drawings at a different size will impact the scale. The Contractor, Owner and/or recipient of these Drawings shall be responsible for any errors resulting from incorrect copying or printing or any other alteration that causes a change of scale. General Contractor shall refer to all applicable construction procedures as provided in these Drawings or as stated below. Before performing any work or ordering any materials, the General Contractor and/or all Subcontractors shall be responsible for verifying all conditions, inclusions and dimensions of the work. Written dimensions shall take precedence over scaled dimensions. Dimensions indicated are from finished wall surface to finished wall surface unless otherwise indicated. As a minimum standard, all work and materials installed shall be in strict accordance with all applicable codes, regulations and ordinances having jurisdiction. Install all Manufacturer's items, materials and/or equipment in strict accordance with the Manufacturer's recommended instructions, methods and specifications. The General Contractor must maintain a current, complete set of Construction Drawings at the site for review by Subcontractors and others on the Construction Site through all phases of construction. Owner to coordinate with General Contractor for location of project materials staging, temporary office facilities, temporary restroom facilities, and/or temporary utilities for this project, if applicable. Construction shall comply with the accessibility requirements, if applicable, per the Building Code and the Americans with Disabilities Act Accessibility Guidelines. Size, placement and orientation of framing members on Engineered Structural Details override size, placement and orientation of framing members shown on the Construction Drawings. Plumbing, Mechanical, and Electrical Contractors shall not penetrate or cut structural members without written authorization from a licensed Professional Structural Engineer and/or Architect. Provide solid 2x wood blocking within wood stud walls at the anchorage locations of cabinets, door stops, toilet room accessories, mantels, ADA Handbars, TV stands or any other wall anchorage point. Anchorage through gypsum board on new walls is not acceptable. Contractor to obtain any and all required Building Construction Permits associated with the work included in these Construction Drawings. Contractor, Subcontractors and Owner to verify that site conditions are similar to the plans. Any discrepancies that arise from varying site conditions shall be reported to the Owner and Designer prior to construction. Contractor, Subcontractor and/or Owner assumes all liability for construction of project and results of construction using Construction Drawings. A.0: Cover Sheet A.1: Site Plan A.2: Floor Plan A.3: Building Elevations A.4: Building Elevations A.5: Kitchen Elevations A.6: Bathroom Elevations A.7: Interior Elevations A.8: Roof & Ceiling Plan C O N T E N T S : 2012 International Residential Code (IRC 2012) Copyright 2015 S.1: Foundation Plan S.2: Foundation Details E.1: Electrical Plan M.1: Mechanical Plan P r i n t S c a l e : 24"x36" SAMPLE PLANS NOT FOR CONSTRUCTION

Upload: others

Post on 08-Dec-2021

2 views

Category:

Documents


0 download

TRANSCRIPT

Revisions:

SAM

PLE

PLA

NS

NO

T FO

R C

ON

STR

UC

TIO

N

Date:

Sheet:

Title:

1. NOT FOR CONSTRUCTION2. 3. 4. 5.6.7.

COVER SHEET

A.0

A.9: Building SectionsA.10: Framing PlanA.11: Shear Wall DetailsA.12: Framing DetailsA.13: Framing Details

GreenLeaf DesignsTulsa, OK

918-524-9721

GreenLeafArchitecture.com

Stamp:

DESIGN CRITERIA

CODE: 2012 International Residential Code (2012 IRC)BUILDING TYPE: Light Framed Wood, Single-Family Residential StructureLOADS:

Dead Loads:Roof- 22 PSFFloor- 32 PSF

Live Loads:Roof- 20 PSFFirst Floor & Stairs- 100 PSF

Snow Loads:Ground Snow Load (Pg)- 15 PSFRoof Snow Load (Ps)- 15 PSFSnow Roof Slope Factor (Cs)- 1.0Importance Factor (Is)- 1.0

Wind Loads: (ASCE 7-05)Basic Wind Speed (3 sec gusts)- 100 MPHExposure- CImportance Factor (Iw)- 1.0

Seismic Load: (ASCE 7-05)Importance Factor (Ie)- 1.0Seismic Use Group- II - NormalSeismic Soil Profile Type- DSeismic Design Category- BBasic Seismic Force Resisting System- Light Framed Walls w/ Shear PanelsSeismic Response Modification Factor (R)- 6.5Analysis Procedure Used- Equivalent Lateral Force

Soils:Undisturbed Earth- 2,500 PSIBedrock- 25,000 PSI

FIRE SPRINKLER: NoFIRE ALARM SYSTEM: Yes

GENERAL NOTES

Drawings are intended to be printed on 24"x36" (Arch D) paper. Printing these drawings at a different sizewill impact the scale. The Contractor, Owner and/or recipient of these Drawings shall be responsible forany errors resulting from incorrect copying or printing or any other alteration that causes a change ofscale.

General Contractor shall refer to all applicable construction procedures as provided in these Drawings oras stated below.

Before performing any work or ordering any materials, the General Contractor and/or all Subcontractorsshall be responsible for verifying all conditions, inclusions and dimensions of the work.

Written dimensions shall take precedence over scaled dimensions. Dimensions indicated are fromfinished wall surface to finished wall surface unless otherwise indicated.

As a minimum standard, all work and materials installed shall be in strict accordance with all applicablecodes, regulations and ordinances having jurisdiction.

Install all Manufacturer's items, materials and/or equipment in strict accordance with the Manufacturer'srecommended instructions, methods and specifications.

The General Contractor must maintain a current, complete set of Construction Drawings at the site forreview by Subcontractors and others on the Construction Site through all phases of construction.

Owner to coordinate with General Contractor for location of project materials staging, temporary officefacilities, temporary restroom facilities, and/or temporary utilities for this project, if applicable.

Construction shall comply with the accessibility requirements, if applicable, per the Building Code and theAmericans with Disabilities Act Accessibility Guidelines.

Size, placement and orientation of framing members on Engineered Structural Details override size,placement and orientation of framing members shown on the Construction Drawings.

Plumbing, Mechanical, and Electrical Contractors shall not penetrate or cut structural members withoutwritten authorization from a licensed Professional Structural Engineer and/or Architect.

Provide solid 2x wood blocking within wood stud walls at the anchorage locations of cabinets, door stops,toilet room accessories, mantels, ADA Handbars, TV stands or any other wall anchorage point. Anchorage through gypsum board on new walls is not acceptable.

Contractor to obtain any and all required Building Construction Permits associated with the work includedin these Construction Drawings.

Contractor, Subcontractors and Owner to verify that site conditions are similar to the plans. Anydiscrepancies that arise from varying site conditions shall be reported to the Owner and Designer prior toconstruction. Contractor, Subcontractor and/or Owner assumes all liability for construction of project andresults of construction using Construction Drawings.

A.0: Cover SheetA.1: Site PlanA.2: Floor PlanA.3: Building ElevationsA.4: Building ElevationsA.5: Kitchen ElevationsA.6: Bathroom ElevationsA.7: Interior ElevationsA.8: Roof & Ceiling Plan

CONTENTS:

2012 International Residential Code (IRC 2012) Copyright 2015

S.1: Foundation PlanS.2: Foundation DetailsE.1: Electrical PlanM.1: Mechanical Plan

Print Scale:24"x36"

SAMPLE PLANS

NOT FOR CONSTRUCTION

210'

-0 1

/8"

-90.

325'-0 1/8"180.0°

210'

-0 1

/8"

90.0

°

325'-0 1/8"0.0°

-2

-1

0 0

0

0

0 0

0

0

0

0

N

5'

~194'-10"

~90'

-9"

~60'-8"

~57'

-6"

~325'

~210

'

111'

10'

25'

14'-8"

120'

113'

E /

LE

/ L

C /

WC

/ W

Existing TreeTo Remain

Existing TreeTo Remain

Existing TreeTo Remain

Existing TreeTo Remain

New Drive(3,840 sf)

Buried 4" ABSw/ Cleanout

New 36" Gate

New Walk

S. 4475 ROAD

Existing TreeTo Remain

Tree Line

REAR ALLEY

Buried Gas Line

Septic System

36"x60"x4" Slab

Planter Bed

Buried 1,000 gal.LP Tank

New 36" Gate

New 36" Gate

LAKE ROAD

New 6' Fence

New 4" Slab(~70sf)

Leech Field

HVAC

Planter Bed

WaterMeter

3/4" BuriedWater SupplyBuried Elec

Supply

StepStones

Planter Bed

Planter Bed

Planter BedPlanter Bed

1" Course FillStone Graded (6" Deep)

LandscapeBoulder

LandscapeBoulder

SS S SSS

G G

E / L E / L

C / W C / W / /

LEGENDWATER SUPPLY LINES

SANITARY SEWER LINES

ELECTRICAL SERVICE

GAS LINE

Revisions:

SAM

PLE

PLA

NS

NO

T FO

R C

ON

STR

UC

TIO

N

Date:

Sheet:

Title:

1. NOT FOR CONSTRUCTION2. 3. 4. 5.6.7.

GreenLeaf DesignsTulsa, OK

918-524-9721

GreenLeafArchitecture.com

A.1SITE PLAN

Stamp:

EROSION CONTROL NOTES:- Install silt fence prior to any excavation orconstruction.- Minimize site disturbance by tight control ofexcavation limits.- All exposed soil shall be mulched with straw orwood chips to minimize soil erosion. No soil shall beleft in an exposed condition. It is recommended thatthe contractor maintain a stock pile of this materialon site for quick application.- Hydroseed with a wood cellulose fiber mulchapplied at a rate of 2,000#/acre. Use an organictackifier at no less than 150 #/acre or permanufacture's recommendation if higher. Applicationof tackifier shall be heavier at edges, in valleys andat crests of banks and other areas where seed canbe moved by wind or water.- Dispersion trenches shall overflow onto nativeundisturbed ground. No site disturbance belowtrenches.

GRADING NOTES:- Contractor to verify location of all existing utilities.- Provide positive drainage away from building.- Final grade to convey surface drainage towardrock channels and dispersion trenches.- Areas to be filled shall be cleared, grubbed toremove trees, vegetation, roots and otherobjectionable material and stripped of topsoil.- Place fill slopes with a gradient steeper that 3:1 inlifts not to exceed 8 inches, and make sure each liftis properly compacted.

Site PlanScale: 1"=20'

2012 International Residential Code (IRC 2012) Copyright 2015

UTILITY LOCATE

Prior to excavation Contractor to schedule autility locate.

Okie Dig Phone number:811 or 1-800-522-OKIE (6543)

SHEET NOTES:

- Final grade to slope 6" per 10'-0" away from thehouse for the first 10'-0".- All concrete pads to slope at 5% or 2" per 1'-0" awayfrom building.- General Contractor responsible for all utility locatesand subsurface utility engineering for this project.- General Contractor responsible for contacting SiteWise prior to digging for utility locate service.Call 811 or1-800-522-6543- General Contractor to immediately notify Site Wise ifun-located utilities are encountered.- 3/4" Domestic water line to be type 'K' copper.- Drives and walks to be 4" concrete, minimum 3,000psi at 28 days.- The General Contractor shall be responsible forrepairing any trenches or excavations that settle for aminimum of 1 year.- The General Contractor shall prevent sediment,debris and all other pollutants from entering the stormsewer system during all construction operations.

Print Scale:24"x36"

SAMPLE PLANS

NOT FOR CONSTRUCTION

C01C01

C02C02

C39C39

C02C02

C03C03

C04C04

C37C37

C17C17

C20C20

C11C11

C10C10

C11C11 C16C16

C17C17

C18C18

C19C19

DW

C28C28

C29C29

C29C29

C24C24

C18C18

C25C25C27C27

C23C23

C36C36

C08C08

C21C21

C01C01

C02C02

C39C39

C02C02

C03C03

C04C04

C37C37

C17C17

C20C20

C11C11

C10C10

C11C11 C16C16

C17C17

C18C18

C19C19

DW

C28C28

C29C29

C29C29

C24C24

C18C18

C25C25C27C27

C23C23

C36C36

C08C08

C21C21

C32C32 C26C26

C06C06

WH

C34C34

C34C34

C12C12

C13C13

C14C14

C15C15

C22C22

C05C05

C07C07

C33C33

C40C40 C30C30 C31C31

C38C38

C33C33

C35C35

D02D02

W11W11

W03W03 D15D15 W03W03

W14W14

W04W04

W06W06

W13W13

W01W01

W07W07

W08W08

W08W08W08W08

D04D04

D14D14

D19D19

D16D16

D07D07

D11D11

D11D11

D08D08D09D09

W05W05

W12W12

W09W09

D03D03

D10D10D12D12

4070

D05D05

D01D01

D18D18

D17D17

D21D21D24D24

D22D22

D06D06

3070 13070

3368

W16W16

W02W02W10W10 W15W15

8070

D13D13

D23D23

UP

UP

Radiant HeatFlooring

Radiant HeatFlooring

Radiant HeatFlooring Radiant Heat

Flooring

19'-1" x 15'-6"280 sq ft

5'-0" x 17'-4"87 sq ft

32'-3" x 4'-2"131 sq ft

5'-0" x 5'-10"29 sq ft

13'-0" x 6'-6"

82 sq ft

11'-0" x 11'-0"121 sq ft

5'-0" x 9'-0"45 sq ft

5'-0" x 9'-0"45 sq ft

16'-8" x 14'-4"235 sq ft

10'-8" x 13'-0"138 sq ft

15'-1" x 19'-11"291 sq ft

8'-0" x 6'-2"49 sq ft

12'-10" x 11'-0"141 sq ft

5'-0" x 7'-0"35 sq ft

18'-4" x 8'-10"161 sq ft

22'-0" x 23'-0"515 sq ft

16'-8" x 11'-10"172 sq ft

12'-1" x 6'-9"78 sq ft

11'-0" x 12'-0"137 sq ft

3'-11" x 5'-6"22 sq ft

20'-7" x 6'-0"163 sq ft

9'-11" x 8'-1"55 sq ft

4'-0" x 16'-10"75 sq ft

5'

2'-6 1/8"

7'-0

1/2

"

11'

61'-6

1/8

"

12'-7

3/8

"14

'-5 1

/2"

10'-8

"23

'-9 1

/4"

7 1/

4"

3'-1

"1'

-1 1

/16"

16'

3'2'

-0 3

/4"

10'-5

"

1'-1

1 3/

4"

1'-8

1/2

"

9'-1

5/1

6"

18'-4

1/2

"5'

-0 1

/2"

45'-3

"

2'12

'9'

-1 3

/4"

9'-1

3/4

"12

'-11

1/2"

4'-5

1/2

"3'

-1"

4'-5

1/2

"3'

-7 3

/8"

1'-1

0"3'

-8 3

/8"

3'-8

"1'

-10"

3'-7

3/4

"4'

-11

1/4"

3'-1

"4'

-11

1/4"

2'-4 7

/8"

2'-1 15/16"

69'-6 1/8"

11'-8 1/4"2'-8 1/4"17'-1 3/4"1'-7 1/4"1'-9 1/4"10'-3"1'-8"5'-0 3/4"4'-7 1/4"13'-0 3/8"

1'-5"2'-1"1'-1 1/4"1'-1"6'-4"5'-7 3/8"

11"8'-5"11"

2'-1"2'-7"1'-8"6'-1"1'-8"2'-7"5 3/4"

4'-0 1/8"6'-4 1/4"1'-3 7/8"

2'-1 15/16"

13'-4 1/2" 7'-9" 11'-3 3/4" 2'-8 1/4" 11'-4 1/2"

2'-10 1/4" 6'-3" 2'-3 1/4"

2'-3" 8'-5" 2'-8 1/2" 10 3/8" 6'-1" 9 5/8" 2'-10 1/2" 6'-3" 2'-2 1/4"

69'-6 1/8"

23'-0 1/8"

5'-5 5/8" 3'-1" 5'-11" 3'-1" 5'-5 1/2"

PWDR

PORCH

PORCH

PANTRY

MASTER BDRM

LAUNDRY

MASTER BATH

HALL

BREAKFASTNOOK

GARAGE

ENTRY

STUDY

BEDROOM 2

BEDROOM 3

MASTERCLOSET

BATH 2

BATH 3LIVING

KITCHEN

GALLERY

Direct VentGas Insert

4" Cleanout

PouredShowerPan

HALL

Frameless 3/8"Glass Panel

Stone Veneer

Floor Drain

Dryer Vent

Exhaust Vent

42" Bar

Elec Meter

Small Pet AccessDoor Installed InDoor Panels

24x32Attic

Access

TLT RM

EL3A.4EL3A.4

EL4A.4EL4A.4

EL2A.3EL2A.3

EL1A.3EL1A.3

BS2A.9BS2A.9

BS1A.9BS1A.9

24x48Attic

Stairs

CrownMolding

CrownMolding

CrownMolding

CrownMolding

CrownMolding

TrayCeiling

TrayCeiling

TrayCeiling

TrayCeiling

TrayCeiling

9' Ceiling

9' Ceiling

9' Ceiling

9' Ceiling

9' Ceiling

10' Ceiling

Frameless 3/8"Glass Door & Panel

Glass PanelDoor

Glass PanelDoors

Glass BlockWindow

Deco GableBracket

Deco GableBracket

Deco GableBracket

Deco GableBracket

N

Revisions:

SAM

PLE

PLA

NS

NO

T FO

R C

ON

STR

UC

TIO

N

Date:

Sheet:

Title:

1. NOT FOR CONSTRUCTION2. 3. 4. 5.6.7.

GreenLeaf DesignsTulsa, OK

918-524-9721

GreenLeafArchitecture.com

Stamp:

MAIN LEVELFLOOR PLAN

A.2

LIVING AREA Main Level Area: 2,277 S.F. Utility Room Area: 34 S.F. Garage Area: 515 S.F. Covered Porch Area: 324 S.F. Total Area: 3,150 S.F.

PROJECT NOTES:

Foundation- Perimeter Footing: 24"x21" cont. min. 3,500 psi @28 days- Interior Footing: 21"x18", min. 3,500 psi @ 28 days- Walk/Drive Footing: 12"x18" min. 2,500 psi @ 28 days- CMU Core Fill: 4,000 psi @ 28 days- Concrete Slab: 4" concrete slab, min. 3,000 psi @ 28 days- Drives/Walks: 4" concrete slab, min. 3,000 psi @ 28 days

Framing- Exterior walls to be framed with 2"x6" lumber, 16" OC.- Interior partition walls to be framed with 2"x4" lumber, 16"OC.- Ceiling Joist framing to be 2"x8", 16" OC.- Roof Ridges to be 2"x12" LVL- Roof Rafters to be 2"x10" lumber 16" OC.

Exterior Veneer- Wall Veneer: Hardie Siding / Masonry- Fascia: 7-1/2" HardieTrim HZ10- Soffit: 18" HardieSoffit vented HZ10- Porch/Portico Ceiling: 4'x8' Hardie Soffit Beaded PorchPanels- Corner Boards: 1"x6" HardieTrim HZ10

Roofing- Dimensional Architect Asphalt Shingle- Gutters to be 5" (6" ok) seamless metal gutters w/downspouts.

Electrical- All electrical fixtures to be Energy Star rated when possible.- All ceiling fans to be Energy Star rated.- All bath fans to be Energy Star rated.- All recessed light fixtures to have LED bulbs and havedimmer controlled switches.- All switches to be 'toggle' style.- Undercabinet LED lighting to be installed in Kitchen, switchcontrolled.- Install new security system, to be selected by Owner.- Install new in-floor low voltage radiant heat systems inMaster Bedroom, Master Bathroom, Living, Kitchen andBreakfast Nook.

Plumbing/Mechanical- Install new undermount sink in Kitchen, Bar and Baths.- Install new adult height, elongated toilets- All bath fans to be ducted to exterior.- New 15 SEER Heat Pump System, 2-zones. One blower tobe installed in attic and one blower to be installed in UtilityRoom.- Install new septic system.- Install new buried LP tank.- Water Heater to be new 80 Gallon high efficiency smartwater heater

Insulation- Wall insulation to be min. R-20 Kraft faced batt insulation.- Ceiling Joist Insulation to be min. R-38 blown (non-shrink)insulation.

Drywall- Install 1/2" on new framed interior partition walls, to bescrewed, mud, taped and textured.- Install 5/8" Type-C ceiling rock on ceiling surfaces. mud,taped and finished.- Install 1/2" moisture board in shower area.- Install 5/8" Type-X fire rock on Garage, Utility and understair wall and ceiling surfaces.- All corners to be 'radius' edging.- Drywall to wrap to windows.- All walls and ceilings to have 'knockdown' texture.- All drywall to be installed with 1-1/4" coarse thread screws,no nails to be permitted.

Flooring- Install tile flooring in all Bath areas.- Install Stained Concrete Flooring in Master Bedroom,Study, Hall, Dining, Laundry and Living Room.- Install carpet in Bedroom 2 and Bedroom 3.- Utility Room and Garage areas to have unfinished concretefloor.

Windows- Install new Energy Star compliant, windows on all floors.- Bedroom windows to meet egress requirements.- All windows to be sealed with minimum expansion foam.

Doors- Install Energy Star compliant exterior Entry, Side and Reardoors.- Front, Side and Rear doors keyed alike. - All doors to be sealed with minimum expansion foam.- Utility Room and Garage walk doors to be self-closing withspring loaded hinges.

Cabinetry- Install adult height (36") vanity cabinets in Master Bathroomand Powder Room.- Install standard height (32") vanity cabinets in BedroomBathrooms.- All cabinets to be installed as shown.- All cabinetry to have plywood boxes.- Kitchen cabinetry to have crown molding and light railmoldings on upper cabinets.- Built-in Cabinetry to have finished wood tops.

Countertops- Install 3-cm granite with 6" backsplash, under-mount sink inall Kitchens and Baths.- Install new granite countertops in Laundry Room.- Granite to have 'eased edge' edging.

Main Level Floor PlanScale: 1/4"=1'

2012 International Residential Code (IRC 2012) Copyright 2015

PROJECT NOTES CONT:

Appliances- All standard appliances to meet or exceed EnergyStar standards when possible.- Water Heater to be 80 Gallon, High-efficiencytanked heater.- All Garbage Disposals to be minimum 3/4 HP.- Appliances to be installed per Manufacturer'sInstallation Instructions.

Interior Millwork- All base molding to be 5-1/2" paint grade wood.- All casing to be 3-1/2" paint grade wood.- All Crown Molding (except cabinetry) to be 6" paintgrade wood, basic style.- Install paint-grade wood closet shelves w/ heavyduty hangar rods, as shown.- Install new hollow-core, paint grade interior doorsthroughout, as shown.- Fireplace mantle to be paint grade wood, basicpattern. See Fireplace Elevation.

Paint- All Kitchens, Baths, Garages and Laundry rooms tobe painted with semi-gloss paint. One coat primer,two coats paint.- All Living, Dining, Hall, Entry, Closet and Bedroomsto be painted with satin/eggshell paint. One coatprimer, two coats paint.- All trim moldings and doors to be stained with glossor semi-gloss stain. One coat primer, two coats paint.- All Exterior siding paint to be painted with semi-gloss paint. Three coats paint. 100% Acrylic- All Exterior trim, metal railings and doors to bepainted with gloss paint. Three coats paint. 100%Acrylic

Glazing- New tempered 3/8" heavy glass shower door withframeless hardware.- Install new beveled vanity mirror in Baths.- Glass panels in interior doors and cabinets to betempered.

Hardware- Install new door hardware on all interior doors.- Install new towel bars, TP holders and other bathaccessories in Bathrooms, fixture location to beverified with Owner.- Install new white metal HVAC registers.

SHEET NOTES:

- All wall lumber and posts shall be treated wherecomes in contact with concrete.

- No roof penetrations allowed on street facing roofplanes. All roof penetrations to be located in rear ofhome where possible.

- Every bedroom shall be provided with an egresswindow with finish sill height not greater than 42" abovethe finish floor height and shall have a minimumopenable area of 5.7 sq. Ft. (5.0 sq. ft. on first level).

- Doors between Garage and living area shall be 1-3/4"tight fitting solid core doors with a rating of 60 minutes.Door shall be self-closing.

- Exterior exit doors to be 36" min.

Print Scale:24"x36"

Contractor, Owner and/orSubcontractors review and verify alldimensions, Specs, andconnections before Constructionbegins.

Electrical system code: sec.2701Mechanical system code: sec.2801Plumbing system code: sec.2901

SAMPLE PLANS

NOT FOR CONSTRUCTION

8'-1

1 7/

8"

15'-3

5/8

" 18'-1

3/4

"

22'-2

1/4

"

8'-1

1"

15'-6

"

22'-2

3/4

"

Deco Gable Bracket

Deco Gable Bracket

Asphalt Shingle Roofing

Stone Veneer

Stone Veneer

Brick Veneer

FIN FLR100'-0"

FIN FLR100'-0"

Garage Flr98'-8"

W06W06W13W13

W01W01W07W07W08W08W08W08

Heat PumpHose Bib

DSDS DS DS DS

6 : 12

13'-2

7/8

"

8'-1

0 3/

4"

14'-1

3/8

"

22'-1

3/4

"

Fin Flr100'-0"

Garage Flr98'-8"

HardieSiding

HardieSiding

Asphalt Shingles

StoneStone Stone

Brick

W03W03D15D15

W03W03W14W14 W02W02

W10W10

W15W15 Elec Meter

Heat Pump

Hose BibHose Bib Hose Bib

FP Vent

DSDS DS

4" Cleanout

Solar Attic Fan Solar Attic Fan

6 : 12

Revisions:

SAM

PLE

PLA

NS

NO

T FO

R C

ON

STR

UC

TIO

N

Date:

Sheet:

Title:

1. NOT FOR CONSTRUCTION2. 3. 4. 5.6.7.

GreenLeaf DesignsTulsa, OK

918-524-9721

GreenLeafArchitecture.com

Stamp:

EXTERIORELEVATIONS

A.32012 International Residential Code (IRC 2012) Copyright 2015

East ElevationScale: 1/4" = 1'

West ElevationScale: 1/4" = 1'

EXTERIOR FINISH NOTES:

- Exterior finish to be siding and masonry over 7/16 OSBply. Window & door trim color by owner.- Roofing to be dimensional asphalt over 30# felt, 7/16"OSB ply.- Downspouts to collect roof run off to be directed awayfrom structure.- Finish grade shall slope away from structure min. 1/2"per 1'-0" of run for first 10'.

ROOFING NOTES:

Main Roof : 8:12 Gutters: 5" (6" ok) Seamless Metal GuttersRoofing: Dimensional Architect Asphalt ShingleRoof Overhang to be 18" Gables and 18" Eaves

Print Scale:24"x36"

EL2A.3EL2A.3

EL1A.3EL1A.3

SAMPLE PLANS

NOT FOR CONSTRUCTION

Hardie Siding

Stone

Stone

Asphalt Shingles

D04D04D14D14

W09W09

Elec Meter

Hose BibHose Bib Hose Bib

Dryer Vent

FP Vent

DS DS DSDS

Septic

Buried LP

4" Cleanout

Solar Attic FanSolar Attic Fan

6 : 12

6 : 12

Asphalt Shingles

Hardie Siding

StoneStone Stone

W04W04W08W08

W05W05W12W12W16W16

Heat Pump

Hose Bib Hose BibHose Bib

FP Vent

DSDS DS DS DS DS DS

Septic

Buried LP

Solar Attic FanSolar Attic Fan

6 : 12

6 : 12

6 : 12

6 : 126 : 12

Revisions:

SAM

PLE

PLA

NS

NO

T FO

R C

ON

STR

UC

TIO

N

Date:

Sheet:

Title:

1. NOT FOR CONSTRUCTION2. 3. 4. 5.6.7.

GreenLeaf DesignsTulsa, OK

918-524-9721

GreenLeafArchitecture.com

Stamp:

EXTERIORELEVATIONS

A.42012 International Residential Code (IRC 2012) Copyright 2015

North ElevationScale: 1/4" = 1'

South ElevationScale: 1/4" = 1'

EXTERIOR FINISH NOTES:

- Exterior finish to be siding and masonry over 7/16 OSBply. Window & door trim color by owner.- Roofing to be dimensional asphalt over 30# felt, 7/16"OSB ply.- Downspouts to collect roof run off to be directed awayfrom structure.- Finish grade shall slope away from structure min. 1/2"per 1'-0" of run for first 10'.

ROOFING NOTES:

Main Roof : 8:12 Gutters: 5" (6" ok) Seamless Metal GuttersRoofing: Dimensional Architect Asphalt ShingleRoof Overhang to be 18" Gables and 18" Eaves

Print Scale:24"x36"

EL3A.4EL3A.4

EL4A.4EL4A.4

SAMPLE PLANS

NOT FOR CONSTRUCTION

C03C03

C37C37

C17C17

C20C20

C11C11

C10C10

C11C11 C16C16

C17C17

C18C18

C19C19

DW

C28C28

C29C29

C29C29

C24C24

C18C18

C25C25C27C27

C23C23

C36C36

C08C08

C21C21

C03C03

C37C37

C17C17

C20C20

C11C11

C10C10

C11C11 C16C16

C17C17

C18C18

C19C19

DW

C28C28

C29C29

C29C29

C24C24

C18C18

C25C25C27C27

C23C23

C36C36

C08C08

C21C21

C12C12

C13C13

C14C14

C15C15

C22C22

C07C07

C33C33

C40C40 C30C30 C31C31

C33C33

C35C35

5'2'

-6"

2'2'

-6"

1'1'

-6"

2'3'

9"9"

1'4'

4'

3'2'

-6"

2'-6

"1'

3'1

1/2"

5'2'

-9"

2'-9

"1'

-3"

2'-9

"2'

2'-9" 2'-9" 2'-9"

1'-6" 1'-3" 2'-9" 3'

9"3'

2'1'

-6"

1'-3

"3'

PANTRY

MASTER CLOSET

KITCHEN

GALLERY

WasteBasketCabinet

Tray DividerCabinet

GlassDoors

HALL

Pull-outSpice

Pull-outUtensil

Micro/Oven

GlassDoors

Tilt-outDrawers

Adj

usta

ble

She

lves

60"Fridge/Freezer

Open Facew/ 2= Roll-out Shelves

3'1'

-6"

3'

7'-9

"

3'1 1/2"

5' 2'-9" 2'-9" 4' 1' 1'

3'

1 1/2"

5' 2'-9" 2'-9" 1'-3" 2'-9" 2'

Glass Doors

GlassPantryDoors

Oven/Micro

C07C07

C37C37 C17C17

C33C33

C12C12 C13C13 C14C14

C15C15Dbl Fridge

C36C36

C33C33 C35C35

9" 3' 2' 1'-6" 1'-3" 3'

3'

Tilt-outDrawers

Tray Cabinetw/ Divider

LazySusanRoll-out

Shelves

C20C20 C16C16C18C18C19C19

DW

C29C29

3'-3

"1'

-6"

3'

3' 2'-9" 1'-3" 1'-6"

2'-9" 2'-9" 2'-9"

3070

C16C16 C17C17 C28C28

C40C40C30C30C31C31

C21C21

9" 9" 3' 2' 1'-6" 1'

3'

Pull-outWaste BinCabinet

Pull-outSpiceCabinet

Pull-outUtilityCabinet

RangeBase

FinishedEnd

FinishedEnd

C03C03C29C29 C24C24 C18C18C25C25

Hood

1' 4' 4'

3' C27C27 C23C23

Hood

3'

3'

Hood

C08C08

Revisions:

SAM

PLE

PLA

NS

NO

T FO

R C

ON

STR

UC

TIO

N

Date:

Sheet:

Title:

1. NOT FOR CONSTRUCTION2. 3. 4. 5.6.7.

GreenLeaf DesignsTulsa, OK

918-524-9721

GreenLeafArchitecture.com

Stamp:

Island Elevation

Kitchen Elevation

Island Elevation

KITCHENELEVATIONS

2012 International Residential Code (IRC 2012) Copyright 2015

Island Elevation A.5

Kitchen FloorplanScale: 1/2" = 1'

Kitchen Elevation

Bar Elevation

Print Scale:24"x36"

KITCHEN NOTES:- Confirm cabinet color and species with Owner prior to ordering.- Confirm cabinet door & drawer styles with Owner prior to ordering.- Install cabinet door and drawer hardware on site.- Cut all cabinet openings on site, see manufacturer appliancespecifications.- Trim Moldings include: 3" Crown Molding, 1-1/2" Light Rail, 3/4"Scribe, 4" Toe-kick moldings.- Install moldings on site; match cabinet color; confirm profile anddimension with Owner.- Confirm final materials for backsplash and countertop with Ownerprior to ordering.- Install all appliances per Manufacturers Installation Instructions.

SAMPLE PLANS

NOT FOR CONSTRUCTION

1'-6" 4'-6"

7'-9

"

3'4'-6" 1'-6"

D18D18

C02C02C02C02

C32C32C26C26

MirrorMirrorTRTR

D17D17

W10W10

Pedestal Tub

Shwr Pan

Shwr ValveTB TB

2'

3'

ToiletPed Sink

Mirror

TP

TRC38C38

3'-3"

2'-8

"

W12W12

ToiletTub C39C39

Mirror

TR

TP

3'-3"

2'-8

"

W05W05

ToiletC01C01 Tub

MirrorTR

TP

Revisions:

SAM

PLE

PLA

NS

NO

T FO

R C

ON

STR

UC

TIO

N

Date:

Sheet:

Title:

1. NOT FOR CONSTRUCTION2. 3. 4. 5.6.7.

GreenLeaf DesignsTulsa, OK

918-524-9721

GreenLeafArchitecture.com

Stamp:

Bath 3Elevation

Master BathElevation

PowderElevation

2012 International Residential Code (IRC 2012) Copyright 2015

INTERIORELEVATIONS

Master BathElevation

Bath 2Elevation A.6

BATHROOM NOTES:- Confirm cabinet color and species with Owner prior to ordering.- Confirm cabinet door & drawer styles with Owner prior to ordering.- Install cabinet door and drawer hardware on site.- Cut all cabinet openings on site, see manufacturer appliancespecifications.- Trim Moldings include: 3" Crown Molding, 3/4" Scribe, 4" Toe-kickmoldings.- Install moldings on site; match cabinet color; confirm profile anddimension with Owner.- Confirm final materials for backsplash and countertop with Ownerprior to ordering.

Print Scale:24"x36"

SAMPLE PLANS

NOT FOR CONSTRUCTION

3'-6"

2'-9

"2'

3'3'-6"

DryerWasher

C04C04

C05C05

3'

7'-9

"

D21D21C06C06

5'

7'-9

" Adjustable ShelvesC22C22

3'-9"

7'-9

"

3'-9"

C34C34 C34C34

2'-6" 2' 2'-6"

3'10

"10

"10

"10

"1'

-2"

12" AdjustableShelving

Roll-outShelvesC11C11C10C10C11C11

Revisions:

SAM

PLE

PLA

NS

NO

T FO

R C

ON

STR

UC

TIO

N

Date:

Sheet:

Title:

1. NOT FOR CONSTRUCTION2. 3. 4. 5.6.7.

GreenLeaf DesignsTulsa, OK

918-524-9721

GreenLeafArchitecture.com

Stamp:

Pantry ClosetElevation

2012 International Residential Code (IRC 2012) Copyright 2015

INTERIORELEVATIONSMaster Closet

Elevation

FireplaceElevation

Laundry RoomElevation

Laundry RoomElevation

A.7

LAUNDRY & PANTRY NOTES:- Confirm cabinet color and species with Ownerprior to ordering.- Confirm cabinet door & drawer styles with Ownerprior to ordering.- Install cabinet door and drawer hardware on site.- Cut all cabinet openings on site, see manufacturerappliance specifications.- Trim Moldings include: 3" Crown Molding, 3/4"Scribe, 4" Toe-kick moldings.- Install moldings on site; match cabinet color;confirm profile and dimension with Owner.- Confirm final materials for backsplash andcountertop with Owner prior to ordering.

Master ClosetElevation

Print Scale:24"x36"

SAMPLE PLANS

NOT FOR CONSTRUCTION