ncr personas m series 76 - tranacttranact.com/wp-content/uploads/2011/09/p76-site-prep.pdf ·...

68
NCR Personas M Series 76 Automated Teller Machine Site Preparation B006-6453-D000 1005

Upload: buitram

Post on 04-Apr-2018

222 views

Category:

Documents


3 download

TRANSCRIPT

Page 1: NCR Personas M Series 76 - Tranacttranact.com/wp-content/uploads/2011/09/P76-Site-Prep.pdf · arrival of the NCR Personas M Series 76 Automated ... Personas M Series 76 ATM Site Preparation

NCR Personas M Series 76Automated Teller MachineSite Preparation

B006-6453-D0001005

Page 2: NCR Personas M Series 76 - Tranacttranact.com/wp-content/uploads/2011/09/P76-Site-Prep.pdf · arrival of the NCR Personas M Series 76 Automated ... Personas M Series 76 ATM Site Preparation

FEDERAL COMMUNICATIONS COMMISSION (FCC) RADIO FREQUENCY INTERFERENCE STATEMENTNote: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

Canadian Class A Device DeclarationThis digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus set out in the Radio Interference Regulations of the Canadian Department of Communications.

Le présent appareil numérique n’émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de la classe A prescrites dans le Réglement sur le brouillage radioélectrique édicté par le ministère des Communications du Canada.

Information to UserThis equipment must be installed and used in strict accordance with the manufacturer’s instructions. However, there is no guarantee that interference to radio communications will not occur in a particular commercial installation. If this equipment does cause interference, which can be determined by turning the equipment off and on, the user is encouraged to consult an NCR service representative immediately.

CAUTION

NCR Corporation is not responsible for any radio or television interference caused by unauthorised modifications of this equipment or the substitution or attachment of connecting cables and equipment other than those specified by NCR. Such unauthorized modifications, substitutions, or attachments may void the user’s authority to operate the equipment. The correction of interference caused by such unauthorized modifications, substitutions, or attachments will be the responsibility of the user.

The ATM complies with the following Electromagnetic Compatibility (EMC) directives and standards for IT equipment:

• 89/336/EEC ‘EMC Directive’• 92/31/EEC ‘Amending EMC Directive’• 93/68/EEC ‘CE Marking Directive’.

For further information, refer to the Electromagnetic Compatibility (EMC) and Safety section.

NOTICEThis is a contractual document. It contains important warnings and confers important legal rights and obligations. You are advised to read it carefully.

It is the responsibility of the customer to assure that all installation preparations are complete and in compliance with all specifications and requirements of NCR and all applicable national, state, or local codes, regulations and laws.

The product described in this book is a licensed product of NCR Corporation.

NCR and Personas are trademarks of NCR Corporation.

Other product names mentioned in this publication may be trademarks or registered trademarks of their respective companies and are hereby acknowledged.

It is the policy of NCR Corporation (NCR) to improve products as new technology, components, software, and firmware become available. NCR, therefore, reserves the right to change specifications without prior notice.

All features, functions, and operations described herein may not be marketed by NCR in all parts of the world. In some instances, photographs are of equipment prototypes. Therefore, before using this document, consult with your NCR representative or NCR office for information that is applicable and current.

© 2004, 2005By NCR Corporation, Dayton, Ohio U.S.A.http://www.ncr.comAll Rights Reserved

Page 3: NCR Personas M Series 76 - Tranacttranact.com/wp-content/uploads/2011/09/P76-Site-Prep.pdf · arrival of the NCR Personas M Series 76 Automated ... Personas M Series 76 ATM Site Preparation

Table of Contents

Personas M Series 76 ATM Site Preparation

INTRODUCTION ...............................................................................................................1How to Use This Site Preparation Bookset ....................................................................2Purpose and Audience ....................................................................................................2Site Compliance..............................................................................................................2Customer Responsibilities ..............................................................................................3Product Identification .....................................................................................................4

PACKAGE DIMENSIONS.................................................................................................5Freestanding ...............................................................................................................5Vestibule ....................................................................................................................6

Manoeuvring the ATM Into Position..............................................................................7

ATM DIMENSIONS...........................................................................................................9Front Access ...................................................................................................................9Rear Access...................................................................................................................11

UL Security Enclosure .............................................................................................11CEN Security Enclosure ..........................................................................................13Vestibule with Standard Collar ................................................................................15Vestibule with Advert Collar ...................................................................................15

Coin Dispenser..............................................................................................................16Privacy Panels...............................................................................................................17

ACCESS FOR ALL...........................................................................................................18Height and Depth to Main Facia Items .........................................................................18

Topmost Viewable Facia Item .................................................................................20Task Lighting................................................................................................................20Wheelchair Clearance ...................................................................................................20

ATM CONFIGURATIONS AND ASSOCIATED CLEARANCES ...............................21Coin Dispenser..............................................................................................................21Traditional Full Function ATM ....................................................................................22Currency Dispenser.......................................................................................................22Currency Deposit ..........................................................................................................23Currency Recycle (Deposit/Dispense)..........................................................................24

B006-6453-D000 i

Page 4: NCR Personas M Series 76 - Tranacttranact.com/wp-content/uploads/2011/09/P76-Site-Prep.pdf · arrival of the NCR Personas M Series 76 Automated ... Personas M Series 76 ATM Site Preparation

Currency (Deposit/Dispense)........................................................................................25High Currency Recycle (Deposit/Dispense).................................................................26

INSTALLATION AND SERVICE CLEARANCES........................................................27Coin Clearance..............................................................................................................27

Clearance A - Coin Dispenser..................................................................................27Front Access Clearances ...............................................................................................28

Top-box Clearances .................................................................................................28Clearance B - Front Access UL or CEN L Security Enclosure ...............................30Clearance C - Front Access UL Security Enclosure ................................................31Clearance D - Front Access UL or CEN L Security Enclosure ...............................32Clearance E - Front Access CEN III, CEN VDS or IV LGAI Security Enclosure .33Clearance F - Front Access CEN III, CEN VDS or IV LGAI Security Enclosure..34

Rear Access Clearances (Freestanding)........................................................................35Clearance G - Freestanding Rear Access UL or CEN L Security Enclosure ..........35Clearance H - Freestanding Rear Access UL Security Enclosure ...........................36Clearance I - Freestanding Rear Access UL or CEN L Security Enclosure ............37Clearance J - Freestanding Rear Access CEN III, CEN VDS or IV LGAI Security Enclosure....................................................................................38Clearance K - Freestanding Rear Access CEN III, CEN VDS or IV LGAI Security Enclosure....................................................................................39

Rear Access Clearances (Vestibule) .............................................................................40Clearance L - Vestibule Rear Access UL or CEN L Security Enclosure ................40Clearance M - Vestibule Rear Access UL Security Enclosure ................................41Clearance N - Vestibule Rear Access UL or CEN L Security Enclosure................42Clearance O - Vestibule Rear Access CEN III, CEN VDS or IV LGAI Security Enclosure....................................................................................43Clearance P - Vestibule Rear Access CEN III, CEN VDS or IV LGAI Security Enclosure....................................................................................44Exterior Wall Clearances .........................................................................................45

HOLE IN THE WALL ......................................................................................................46Installation Categories ..................................................................................................46Installing Through a Glass Wall ...................................................................................47Installing Through a New Hole in the Wall..................................................................47Replacing 5675 with Modifications to Hole in Wall ....................................................48Replacing 5875 with Modifications to Hole in Wall ....................................................49

REQUIREMENTS FOR THE FLOOR.............................................................................50Floor Covering ..............................................................................................................50Floor Loading ...............................................................................................................50

Without Coin Dispenser...........................................................................................50With Coin Dispenser (Empty of Coins) ...................................................................50

Bolt Holes Locations ....................................................................................................51Front Access.............................................................................................................51Rear Access..............................................................................................................53

Security Bolts................................................................................................................57

ii B006-6453-D000

Page 5: NCR Personas M Series 76 - Tranacttranact.com/wp-content/uploads/2011/09/P76-Site-Prep.pdf · arrival of the NCR Personas M Series 76 Automated ... Personas M Series 76 ATM Site Preparation

VIDEO CAMERA.............................................................................................................58Ambient Lighting..........................................................................................................58Internal Space Constraint for Fitting a Third-Party Video Camera..............................59

B006-6453-D000 iii

Page 6: NCR Personas M Series 76 - Tranacttranact.com/wp-content/uploads/2011/09/P76-Site-Prep.pdf · arrival of the NCR Personas M Series 76 Automated ... Personas M Series 76 ATM Site Preparation

iv B006-6453-D000

Page 7: NCR Personas M Series 76 - Tranacttranact.com/wp-content/uploads/2011/09/P76-Site-Prep.pdf · arrival of the NCR Personas M Series 76 Automated ... Personas M Series 76 ATM Site Preparation

Personas M Series 76 ATM Site Preparation

Table of Contents

Personas M Series 76 ATM Site Preparation

INTRODUCTION

The Personas M Series 76 is a multi-function Automated Teller Machine (ATM), suitable for interior locations. It is available in front or rear access freestanding variants and also as a rear access vestibule variant, for use through an interior wall.In all illustrations within this book, the freestanding variant will be used; except where the text relates to the vestibule variant specifically.

Freestanding Vestibule

B006-6453-D000 1

Page 8: NCR Personas M Series 76 - Tranacttranact.com/wp-content/uploads/2011/09/P76-Site-Prep.pdf · arrival of the NCR Personas M Series 76 Automated ... Personas M Series 76 ATM Site Preparation

Personas M Series 76 ATM Site Preparation

How to Use This Site Preparation BooksetThe site preparation is part of the Personas M Series 76 Site Preparation Bookset. It acts both as a specifications book, and also as a gateway to the other books in the bookset, which are:● Electrical and Protection Requirements (B006-6454)● Environmental and Planning Requirements (B006-6455)

Purpose and AudienceThis book is intended for architects and those responsible for preparing a site prior to the arrival of the NCR Personas M Series 76 Automated Teller Machine (ATM).Site preparation details are given under the following main sections within this book:Package DimensionsATM DimensionsAccess for AllATM Configurations and Associated ClearancesInstallation and Service ClearancesHole in the WallRequirements for the FloorVideo Camera

Site ComplianceThis document contains the information necessary for the preparation of a site conforming to NCR specifications. It is very important that the site complies with the requirements specified in this document because, once the equipment has been installed, deficiencies in site preparation or the problems caused by these deficiencies are much more difficult to detect and correct. Further, failure to comply with these requirements or to take proper steps to protect equipment against risks identified in this document may cause serious damage to the equipment and to the customer’s business.In addition to the need to comply with the requirements specified, electrical wiring and mechanical systems must also comply with all relevant codes, laws and regulations.It is important that the site be prepared by a customer or his agent who is fully conversant with the special requirements of electronic equipment. The responsibility for ensuring that the site is prepared in compliance with this document remains with the customer.For information and guidance only, a list is provided, in general terms, of those matters for which the customer is responsible. This list is not intended to be comprehensive, and in no way modifies, alters, or limits the responsibility of the customer for all aspects of adequate site preparation.

2 B006-6453-D000

Page 9: NCR Personas M Series 76 - Tranacttranact.com/wp-content/uploads/2011/09/P76-Site-Prep.pdf · arrival of the NCR Personas M Series 76 Automated ... Personas M Series 76 ATM Site Preparation

Personas M Series 76 ATM Site Preparation

NCR staff will be available to answer questions relating to the contents of this document but, except where:

a the customer has been notified that a full or partial consultancy service is available and/or that NCR will be willing to undertake a preliminary or final site survey and

b the customer shall have entered into a formal contract with NCR for provision of the same

no comment, suggestion or advice offered or not offered about preparation of the site nor any inspection of the site whether before or after preparation is to be taken as approval of the location of the site and equipment or of its preparation and NCR will not be liable in respect of any comment, suggestion or advice given by its staff or in respect of any failure to give advice.Finally, only the customer can know the full extent of damage which may be caused to his business by reason of failure of the equipment which is to be installed. For this reason it is the customer’s responsibility to ascertain the extent of any such possible damage to his existing or planned business, and to effect full insurance in respect of it.

Customer ResponsibilitiesThe customer must do or provide the following:● When required by NCR, provide the NCR customer service representative with

appropriate drawings that indicate: ● Location of the equipment● Site wiring (power and signal, paths and lengths) ● Location of other equipment capable of generating electrical noise,

electromagnetic interference, heat, etc.● Make building alterations necessary to meet wiring and other site requirements.● Provide and install all communications cables, wall jacks, special connectors, and

associated hardware.● Provide and install necessary power distribution boxes, conduits, grounds, lightning

protection, and associated hardware.● Make sure all applicable codes, regulations and laws (including, but not limited to,

electrical, building, safety, and health) are met.● Provide and install auxiliary power or other equipment as required.● Provide storage or service areas as required.● Make sure the environmental requirements of the system/unit are met.● Provide floor coverings and environmental systems that limit or control static

electricity build-up and discharge.● Install the product at a height which meets the accessibility regulations of the relevant

country.

B006-6453-D000 3

Page 10: NCR Personas M Series 76 - Tranacttranact.com/wp-content/uploads/2011/09/P76-Site-Prep.pdf · arrival of the NCR Personas M Series 76 Automated ... Personas M Series 76 ATM Site Preparation

Personas M Series 76 ATM Site Preparation

Product IdentificationThe product is identified by a class type number, 6676, and a 4 digit model number, (normally 0100), which is printed on a label fixed inside the top cabinet of the ATM and above the receipt printer. The serial number is unique to each ATM. The tracer number is used to identify where the ATM was built. Please quote all of the serial and tracer numbers, including the prefix, when making reference to the ATM.

Model: XXXX

Hz: 50/60 A:X.X

Serial: XX-XXXXXXXX

Tracer: XX-XXXXX

Vac: XXX

NCR Global Solutions Ltd.

Made in UK

Electromagnetic Compatibility

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:(1) This device may not cause harmful interference, and (2) this device must accept any interferencereceived, including interference that may cause undesired operation.

This apparatus does not exceed Class A limits for radio noise emissions set out in the Radio InterferenceRegulations of Canada.

‘’Complies with FDA Radiation Performance Standards, 21 CFR Subchapter J’‘

Le present appariel n’emet pas de bruits radioelectriques depassant les limites de la classe A prescritesdans le Reglement sur le brouillage radioelectrique du Canada.

Class: 6676

� LR 32207�

LISTED649Automated Teller Machine24 Hour Service Level 1

UL

4 B006-6453-D000

Page 11: NCR Personas M Series 76 - Tranacttranact.com/wp-content/uploads/2011/09/P76-Site-Prep.pdf · arrival of the NCR Personas M Series 76 Automated ... Personas M Series 76 ATM Site Preparation

Personas M Series 76 ATM Site Preparation

PACKAGE DIMENSIONSThe dimensions of a packaged and unpackaged ATM are shown in the following illustrations.

Freestanding

UL and CEN Front Access

UL Rear Access

CEN Rear Access

A 1055 mm(41.54 in.)

1115 mm(43.90 in.)

1141 mm(44.92 in.)

1410 mm

(55.51 in.)

957 mm

(37.68 in.)

1925 mm

(75.79 in.)

1319 mm

(51.93 in.)

927 mm

(36.50 in.)

A

785 mm

(30.91 in.)

B006-6453-D000 5

Page 12: NCR Personas M Series 76 - Tranacttranact.com/wp-content/uploads/2011/09/P76-Site-Prep.pdf · arrival of the NCR Personas M Series 76 Automated ... Personas M Series 76 ATM Site Preparation

Personas M Series 76 ATM Site Preparation

Vestibule

UL Rear Access

CEN Rear Access

A 1115 mm(43.90 in.)

1141 mm(44.92 in.)

1410 mm

(55.51 in.)

957 mm

(37.68 in.)

1925 mm

(75.79 in.)

1319 mm

(51.93 in.)

927 mm

(36.50 in.)

A

785 mm

(30.91 in.)

6 B006-6453-D000

Page 13: NCR Personas M Series 76 - Tranacttranact.com/wp-content/uploads/2011/09/P76-Site-Prep.pdf · arrival of the NCR Personas M Series 76 Automated ... Personas M Series 76 ATM Site Preparation

Personas M Series 76 ATM Site Preparation

Manoeuvring the ATM Into PositionEnsure that doorways and corridors leading to your point of installation are wide enough to allow the package to pass through, or make arrangements to unpack the ATM in an area with sufficient access and then move it to the installation site. Also ensure that any corridors can support the weight of the ATM. Refer to page 50 for the maximum weight of the ATM and its floor loading.The following table gives the minimum dimensions for doorways, corridors with right angle corners and the space required to rotate an ATM on its axis.

Note 1: The dimensions assume the ATM is being moved using equipment that does not extend beyond the ATM or packaging.

Note 2: A surrounding clearance of 6 mm (0.24 in.) has been allowed in the figures.

Note 3: If privacy panels are fitted, the dimensions for an unpackaged ATM will increase by 20 mm (0.79 in.). If the doorway is not wide enough to allow an ATM with privacy panels to pass through, the panels can be removed and installed at a later date.

Freestanding

Packaged ATM(pallet, carton

and lid)

Packaged ATM(pallet and

carton)

Unpackaged ATM

(UL and CEN Front Access)

Unpackaged ATM

(UL Rear Access)

Unpackaged ATM

(CEN Rear Access)

A Doorway or straight corridor

969 mm(38.15 in.)

939 mm(36.97 in.)

797 mm(31.38 in.)

797 mm(31.38 in.)

797 mm(31.38 in.)

B Corridor with corner 1187 mm(46.73 in.)

1134 mm(44.65 in.)

940 mm(37.01 in.)

961 mm(37.83 in.)

970 mm(38.19 in.)

C Rotation about centre 1716 mm(67.56 in.)

1624 mm(63.94 in.)

1327 mm(52.24 in.)

1376 mm(54.17 in.)

1397 mm(55.00 in.)

A B

B

C

B006-6453-D000 7

Page 14: NCR Personas M Series 76 - Tranacttranact.com/wp-content/uploads/2011/09/P76-Site-Prep.pdf · arrival of the NCR Personas M Series 76 Automated ... Personas M Series 76 ATM Site Preparation

Personas M Series 76 ATM Site Preparation

Vestibule

Packaged ATM(pallet, carton

and lid)

Packaged ATM(pallet and

carton)

Unpackaged ATM

(UL Rear Access)

Unpackaged ATM

(CEN Rear Access)

A Doorway or straight corridor

969 mm(38.15 in.)

939 mm(36.97 in.)

812 mm(31.97 in.)

812 mm(31.97 in.)

B Corridor with corner 1187 mm(46.73 in.)

1134 mm(44.65 in.)

972 mm(38.27 in.)

981 mm(38.62 in.)

C Rotation about centre 1716 mm(67.56 in.)

1624 mm(63.94 in.)

1384 mm(54.49 in.)

1406 mm(55.35 in.)

8 B006-6453-D000

Page 15: NCR Personas M Series 76 - Tranacttranact.com/wp-content/uploads/2011/09/P76-Site-Prep.pdf · arrival of the NCR Personas M Series 76 Automated ... Personas M Series 76 ATM Site Preparation

Personas M Series 76 ATM Site Preparation

ATM DIMENSIONS

Front AccessThere are two variants of front access: standard height and low height. Standard height ATMs are configured with a UL, CEN Grade L, CEN Grade III, CEN Grade VdS or CEN Grade IV LGAI security enclosure. Low height ATMs are configured with a UL security enclosure and are only available in the USA.

B006-6453-D000 9

Page 16: NCR Personas M Series 76 - Tranacttranact.com/wp-content/uploads/2011/09/P76-Site-Prep.pdf · arrival of the NCR Personas M Series 76 Automated ... Personas M Series 76 ATM Site Preparation

Personas M Series 76 ATM Site Preparation

The illustration below shows the dimensions for an ATM configured with a UL, CEN Grade L, CEN Grade III, CEN Grade VdS or CEN Grade IV LGAI security enclosure.

Standard Height Low HeightA 97 mm

(3.82 in.)17 mm

(0.67 in.)B 1550 mm

(61.02 in.)1470 mm(57.87 in.)

C 1911 mm(75.24 in.)

1831 mm(72.09 in.)

D 818 mm(32.20 in.)

738 mm(29.06 in.)

E 775 mm(30.51 in.)

695 mm(27.36 in.)

F 2316 mm(91.18 in.)

2236 mm(88.03 in.)

800 mm

(31.50 in.)785 mm

(30.91 in.)

A

1286 mm

(50.63 in.)

596 mm

(23.46 in.)

770 mm

(30.31 in.)

45 mm

(1.77 in.)

1055 mm

(41.54 in.)

D

C

F

B

92 mm

(3.62 in.)

E

760 mm

(29.92 in.)

Service Positionfor Facia Items

10 B006-6453-D000

Page 17: NCR Personas M Series 76 - Tranacttranact.com/wp-content/uploads/2011/09/P76-Site-Prep.pdf · arrival of the NCR Personas M Series 76 Automated ... Personas M Series 76 ATM Site Preparation

Personas M Series 76 ATM Site Preparation

Rear Access

UL Security Enclosure

Freestanding The illustration below shows the dimensions for an ATM configured with a UL security enclosure.

800 mm

(31.50 in.)785 mm

(30.91 in.)

97 mm

(3.82 in.)

760 mm

(29.92 in.)

770 mm

(30.31 in.)

810 mm

(31.89 in.)

45 mm

(1.77 in.)60 mm

(2.36 in.)

1115 mm

(43.90 in.)

818 mm

(32.20 in.)

1550 mm

(61.02 in.)

92 mm

(3.62 in.)

775 mm

(30.51 in.)

1911 mm

(75.24 in.)

1250 mm

(49.21 in.)

2316 mm

(91.18 in.)

Service Positionfor Facia Items

B006-6453-D000 11

Page 18: NCR Personas M Series 76 - Tranacttranact.com/wp-content/uploads/2011/09/P76-Site-Prep.pdf · arrival of the NCR Personas M Series 76 Automated ... Personas M Series 76 ATM Site Preparation

Personas M Series 76 ATM Site Preparation

Vestibule The illustration below shows the dimensions for an ATM configured with a UL security enclosure before a collar has been fitted.

770 mm

(30.31 in.)

800 mm

(31.50 in.)

693 mm

(27.28 in.)

778 mm

(30.63 in.)

722 mm

(28.43 in.)

771 mm

(30.35 in.)

1557 mm

(61.30 in.)

1597 mm

(62.87 in.)

1713 mm

(67.44 in.)

800 mm

(31.50 in.)60 mm

(2.36 in.)

1115 mm

(43.90 in.)

246 mm

(9.69 in.)

1650 mm

(64.96 in.)

12 B006-6453-D000

Page 19: NCR Personas M Series 76 - Tranacttranact.com/wp-content/uploads/2011/09/P76-Site-Prep.pdf · arrival of the NCR Personas M Series 76 Automated ... Personas M Series 76 ATM Site Preparation

Personas M Series 76 ATM Site Preparation

CEN Security Enclosure

Freestanding The illustration below shows the dimensions for an ATM configured with a CEN Grade L, CEN Grade III, CEN Grade VdS or CEN Grade IV LGAI security enclosure.

800 mm

(31.50 in.)785 mm

(30.91 in.)

97 mm

(3.82 in.)

760 mm

(29.92 in.)

770 mm

(30.31 in.)

45 mm

(1.77 in.)

92 mm

(3.62 in.)

1141 mm

(44.92 in.)

775 mm

(30.51 in.)

818 mm

(32.20 in.)

1550 mm

(61.02 in.)

810 mm

(31.89 in.)

86 mm

(3.39 in.)

1911 mm

(75.24 in.)

2316 mm

(91.18 in.)

Service Positionfor Facia Items

1250 mm

(49.21 in.)

B006-6453-D000 13

Page 20: NCR Personas M Series 76 - Tranacttranact.com/wp-content/uploads/2011/09/P76-Site-Prep.pdf · arrival of the NCR Personas M Series 76 Automated ... Personas M Series 76 ATM Site Preparation

Personas M Series 76 ATM Site Preparation

Vestibule The illustration below shows the dimensions for an ATM configured with a CEN Grade L, CEN Grade III, CEN Grade VdS or CEN Grade IV LGAI security enclosure before a collar has been fitted.

770 mm

(30.31 in.)

800 mm

(31.50 in.)

693 mm

(27.28 in.)

778 mm

(30.63 in.)

722 mm

(28.43 in.)

771 mm

(30.35 in.)

1557 mm

(61.30 in.)

1597 mm

(62.87 in.)

1713 mm

(67.44 in.)

800 mm

(31.50 in.)246 mm

(9.69 in.)

1650 mm

(64.96 in.)

86 mm

(3.39 in.)

1141 mm

(44.92 in.)

14 B006-6453-D000

Page 21: NCR Personas M Series 76 - Tranacttranact.com/wp-content/uploads/2011/09/P76-Site-Prep.pdf · arrival of the NCR Personas M Series 76 Automated ... Personas M Series 76 ATM Site Preparation

Personas M Series 76 ATM Site Preparation

Vestibule with Standard CollarThe illustration below shows the dimensions for an ATM with a standard collar fitted.

Vestibule with Advert CollarThe illustration below shows the dimensions for an ATM with an advert collar fitted.

35 mm

(1.38 in.)894 mm

(35.20 in.)

1702 mm

(67.01 in.)

648 mm

(25.51 in.)256 mm

(10.08 in.)

60 mm

(2.36 in.)

35 mm

(1.38 in.)

894 mm

(35.20 in.)

1927 mm

(75.87 in.)

648 mm

(25.51 in.)256 mm

(10.08 in.)

B006-6453-D000 15

Page 22: NCR Personas M Series 76 - Tranacttranact.com/wp-content/uploads/2011/09/P76-Site-Prep.pdf · arrival of the NCR Personas M Series 76 Automated ... Personas M Series 76 ATM Site Preparation

Personas M Series 76 ATM Site Preparation

Coin DispenserThe illustration below shows the dimensions for an ATM with a coin dispenser fitted.

245 mm

(9.65 in.)250 mm

(9.84 in.)

435 mm

(17.13 in.)

224 mm

(8.82 in.)

400 mm

(15.75 in.)

535 mm

(21.06 in.)833 mm

(32.80 in.)795 mm

(31.30 in.)

16 B006-6453-D000

Page 23: NCR Personas M Series 76 - Tranacttranact.com/wp-content/uploads/2011/09/P76-Site-Prep.pdf · arrival of the NCR Personas M Series 76 Automated ... Personas M Series 76 ATM Site Preparation

Personas M Series 76 ATM Site Preparation

Privacy PanelsThe illustration below shows the ATM with privacy panels fitted to either side of the facia. The dimensions are the same for ATMs configured with a UL, CEN Grade L, CEN Grade III, CEN Grade VdS or CEN Grade IV LGAI security enclosure.

1037 mm

(40.83 in.)

805 mm

(31.69 in.)

1325 mm

(52.17 in.)

B006-6453-D000 17

Page 24: NCR Personas M Series 76 - Tranacttranact.com/wp-content/uploads/2011/09/P76-Site-Prep.pdf · arrival of the NCR Personas M Series 76 Automated ... Personas M Series 76 ATM Site Preparation

Personas M Series 76 ATM Site Preparation

ACCESS FOR ALLThe ATM has been designed to meet the height and reach requirements of the ATM user population of the world, both able-bodied and disabled. For wheelchair users, the ATM offers optimised parallel approach, providing easy access, security and private space if installed according to the specifications detailed in this document.

Height and Depth to Main Facia ItemsThe following table gives the height and depth to the main facia items located on the facia. All the height dimensions are calculated from the base of the ATM.

Facia Item

Height(from base of ATM)

Height(from base of ATM)

Low Height ATM

Depth(from front of shelf

or collar)

A Statement 1200 mm(47.24 in.)

1120 mm(44.09 in.)

254 mm(10.00 in.)

B Touch Screen Display 1144 mm(45.04 in.)

1064 mm(41.89 in.)

278 mm(10.94 in.)

C Cash Exit and/or Entry 848 mm(33.39 in.)

768 mm(30.24 in.)

205 mm(8.07 in.)

D No. 5 Key 805 mm(31.69 in.)

725 mm(28.54 in.)

106 mm(4.17 in.)

E Envelope Exit and Entry 848 mm(33.39 in.)

768 mm(30.24 in.)

205 mm(8.07 in.)

F Audio Jack Plug 943 mm(37.13 in.)

863 mm(33.98 in.)

170 mm(6.69 in.)

G Card Reader Motorised 1075 mm(42.32 in.)

995 mm(39.17 in.)

189 mm(7.44 in.)

H Card Reader Dip 1075 mm(42.32 in.)

995 mm(39.17 in.)

169 mm(6.65 in.)

I Receipt 1200 mm(47.24 in.)

1120 mm(44.09 in.)

207 mm(8.15 in.)

J Camera Window 1278 mm(50.31 in.)

1198 mm(47.17 in.)

228 mm(8.98 in.)

K 3rd-Party Camera Window 1426 mm(56.14 in.)

1346 mm(52.99 in.)

272 mm(10.71 in.)

SS

5JKL

18 B006-6453-D000

Page 25: NCR Personas M Series 76 - Tranacttranact.com/wp-content/uploads/2011/09/P76-Site-Prep.pdf · arrival of the NCR Personas M Series 76 Automated ... Personas M Series 76 ATM Site Preparation

Personas M Series 76 ATM Site Preparation

L Check Processor 1180 mm(46.46 in.)

1100 mm(43.31 in.)

205 mm(8.07 in.)

M Top FDK 1055 mm(41.54 in.)

975 mm(38.39 in.)

245 mm(9.65 in.)

N Coin Dispenser 1005 mm(39.57 in.)

925 mm(36.42 in.)

161 mm(6.34 in.)

A C

E

B FC

E

G

H

J MLKD I N

B006-6453-D000 19

Page 26: NCR Personas M Series 76 - Tranacttranact.com/wp-content/uploads/2011/09/P76-Site-Prep.pdf · arrival of the NCR Personas M Series 76 Automated ... Personas M Series 76 ATM Site Preparation

Personas M Series 76 ATM Site Preparation

Topmost Viewable Facia ItemThe following illustration shows the projected angle from the front of the facia to the topmost viewable facia item.

Task LightingA minimum of 200 LUX is required for task lighting.

Wheelchair ClearanceThe following illustration shows the clearance required for wheelchair approach and its turning circle.

59ºStatement

1524 mm

(60.0 in.)

1524 mm

(60.0 in.)

20 B006-6453-D000

Page 27: NCR Personas M Series 76 - Tranacttranact.com/wp-content/uploads/2011/09/P76-Site-Prep.pdf · arrival of the NCR Personas M Series 76 Automated ... Personas M Series 76 ATM Site Preparation

Personas M Series 76 ATM Site Preparation

ATM CONFIGURATIONS AND ASSOCIATED CLEARANCES

If it is likely that the ATM will be fitted with intelligent deposit, currency deposit or high currency recycle (cash acceptor or cash recycler) at a later date, the currency dispenser should be fitted in the right-hand bay (available for UL security only). This will ensure that the installation and service clearances will remain as small as possible and the same as those shown in clearances B, G, and L.For low height ATMs, the currency dispenser must be fitted in the right-hand bay. The installation and service clearance for this type of ATM is shown in clearance B.

Coin DispenserIf the ATM is fitted with a coin dispenser, use the coin clearance in conjunction with the appropriate left-hand and right-hand device clearance.

Left-Hand Bay Right-Hand BayAny Device Any Device

Clearance A See page 27.

AnyDevice

AnyDevice

Coin

B006-6453-D000 21

Page 28: NCR Personas M Series 76 - Tranacttranact.com/wp-content/uploads/2011/09/P76-Site-Prep.pdf · arrival of the NCR Personas M Series 76 Automated ... Personas M Series 76 ATM Site Preparation

Personas M Series 76 ATM Site Preparation

Traditional Full Function ATM

Currency Dispenser

Left-Hand Bay Right-Hand Bay Left-Hand Bay Right-Hand BayCurrency Dispenser Envelope Depository Envelope Depository Currency Dispenser

Front Access Front AccessClearance B - UL or CEN L See page 30. Clearance B - UL only See page 30.

Clearance E - CEN III, IV VDS or IV LGAI See page 33. Configuration not available for CEN

Rear Access (Freestanding) Rear Access (Freestanding)Clearance G - UL or CEN L See page 35. Clearance G - UL only See page 35.

Clearance J - CEN III, IV VDS or IV LGAI See page 38. Configuration not available for CEN

Rear Access (Vestibule) Rear Access (Vestibule)Clearance L - UL or CEN L See page 40. Clearance L - UL only See page 40.

Clearance O - CEN III, IV VDS or IV LGAI See page 43. Configuration not available for CEN

Left-Hand Bay Right-Hand Bay Left-Hand Bay Right-Hand BayCurrency Dispenser Currency Dispenser

Front Access Front AccessClearance B - UL or CEN L See page 30. Clearance B - UL only See page 30.

Clearance E - CEN III, IV VDS or IV LGAI See page 33. Configuration not available for CEN

Rear Access (Freestanding) Rear Access (Freestanding)Clearance G - UL or CEN L Security See page 35. Clearance G - UL only See page 35.

Clearance J - CEN III, IV VDS or IV LGAI See page 38. Configuration not available for CEN

Rear Access (Vestibule) Rear Access (Vestibule)Clearance L - UL or CEN L See page 40. Clearance L - UL only See page 40.

Clearance O - CEN III, IV VDS or IV LGAI See page 43. Configuration not available for CEN

EnvelopeDepository

CurrencyDispenser

EnvelopeDepository

CurrencyDispenser

CurrencyDispenser

CurrencyDispenser

22 B006-6453-D000

Page 29: NCR Personas M Series 76 - Tranacttranact.com/wp-content/uploads/2011/09/P76-Site-Prep.pdf · arrival of the NCR Personas M Series 76 Automated ... Personas M Series 76 ATM Site Preparation

Personas M Series 76 ATM Site Preparation

Currency Deposit

Left-Hand Bay Right-Hand Bay Left-Hand Bay Right-Hand BayCash Acceptor Cash Acceptor

Front Access Front AccessClearance D- UL or CEN L See page 32. Clearance B - UL only See page 30.

Clearance F - CEN III, IV VDS or IV LGAI See page 34. Configuration not available for CEN

Rear Access Rear AccessClearance I - UL or CEN L See page 37. Clearance G - UL only See page 35.

Clearance K - CEN III, IV VDS or IV LGAI See page 39. Configuration not available for CEN

Rear Access (Vestibule) Rear Access (Vestibule)Clearance N - UL or CEN L See page 42. Clearance L- UL only See page 40.

Clearance P - CEN III, IV VDS or IV LGAI See page 44. Configuration not available for CEN

Left-Hand Bay Right-Hand BayCash Acceptor

((UD686) limited availability)

Front AccessClearance C - UL only See page 31.Configuration not available for CEN

Rear AccessClearance H - UL only See page 36.Configuration not available for CEN

Rear Access (Vestibule)Clearance M- UL only See page 41.Configuration not available for CEN

CashAcceptor

CashAcceptor

CashAcceptor(UD686)

B006-6453-D000 23

Page 30: NCR Personas M Series 76 - Tranacttranact.com/wp-content/uploads/2011/09/P76-Site-Prep.pdf · arrival of the NCR Personas M Series 76 Automated ... Personas M Series 76 ATM Site Preparation

Personas M Series 76 ATM Site Preparation

Currency Recycle (Deposit/Dispense)

Left-Hand Bay Right-Hand Bay Left-Hand Bay Right-Hand BayCash Recycler Cash Recycler

Front Access Front AccessClearance D- UL or CEN L See page 32. Clearance B - UL only See page 30.

Clearance F - CEN III, IV VDS or IV LGAI See page 34. Configuration not available for CEN

Rear Access (Freestanding) Rear Access (Freestanding)Clearance I - UL or CEN L See page 37. Clearance G- UL only See page 35.

Clearance K- CEN III, IV VDS or IV LGAI See page 39. Configuration not available for CEN

Rear Access (Vestibule) Rear Access (Vestibule)Clearance N- UL or CEN L See page 42. Clearance L- UL only See page 40.

Clearance P- CEN III, IV VDS or IV LGAI See page 44. Configuration not available for CEN

CashRecycler

CashRecycler

24 B006-6453-D000

Page 31: NCR Personas M Series 76 - Tranacttranact.com/wp-content/uploads/2011/09/P76-Site-Prep.pdf · arrival of the NCR Personas M Series 76 Automated ... Personas M Series 76 ATM Site Preparation

Personas M Series 76 ATM Site Preparation

Currency (Deposit/Dispense)

Left-Hand Bay Right-Hand Bay Left-Hand Bay Right-Hand BayCurrency Dispenser Cash Acceptor Cash Acceptor Currency Dispenser

Front Access Front AccessClearance D- UL or CEN L See page 32. Clearance B - UL only See page 30.

Clearance F- CEN III, IV VDS or IV LGAI See page 34. Configuration not available for CEN

Rear Access (Freestanding) Rear Access (Freestanding)Clearance I- UL or CEN L See page 37. Clearance G- UL only See page 35.

Clearance K- CEN III, IV VDS or IV LGAI See page 39. Configuration not available for CEN

Rear Access (Vestibule) Rear Access (Vestibule)Clearance N- UL or CEN L See page 42. Clearance L- UL only See page 40.

Clearance P- CEN III, IV VDS or IV LGAI See page 44. Configuration not available for CEN

Left-Hand Bay Right-Hand BayCash Acceptor

((UD686) limited availability)Currency Dispenser

Front AccessClearance C- UL only See page 31.Configuration not available for CEN

Rear Access (Freestanding)Clearance H- UL only See page 36.Configuration not available for CEN

Rear Access (Vestibule)Clearance M- UL only See page 41.Configuration not available for CEN

CurrencyDispenser

CashAcceptor

CashAcceptor

CurrencyDispenser

CurrencyDispenser

CashAcceptor(UD686)

B006-6453-D000 25

Page 32: NCR Personas M Series 76 - Tranacttranact.com/wp-content/uploads/2011/09/P76-Site-Prep.pdf · arrival of the NCR Personas M Series 76 Automated ... Personas M Series 76 ATM Site Preparation

Personas M Series 76 ATM Site Preparation

High Currency Recycle (Deposit/Dispense)

Left-Hand Bay Right-Hand Bay Left-Hand Bay Right-Hand BayCurrency Dispenser Cash Recycler Cash Recycler Currency Dispenser

Front Access Front AccessClearance D- UL or CEN L See page 32. Clearance B - UL only See page 30.

Clearance F- CEN III, IV VDS or IV LGAI See page 34. Configuration not available for CEN

Rear Access (Freestanding) Rear Access (Freestanding)Clearance I- UL or CEN L See page 37. Clearance G- UL only See page 35.

Clearance K- CEN III, IV VDS or IV LGAI See page 39. Configuration not available for CEN

Rear Access (Vestibule) Rear Access (Vestibule)Clearance N- UL or CEN L See page 42. Clearance L- UL only See page 40.

Clearance P- CEN III, IV VDS or IV LGAI See page 44. Configuration not available for CEN

CurrencyDispenser

CashRecycler

CurrencyDispenser

CashRecycler

26 B006-6453-D000

Page 33: NCR Personas M Series 76 - Tranacttranact.com/wp-content/uploads/2011/09/P76-Site-Prep.pdf · arrival of the NCR Personas M Series 76 Automated ... Personas M Series 76 ATM Site Preparation

Personas M Series 76 ATM Site Preparation

INSTALLATION AND SERVICE CLEARANCESThe following illustrations show the minimum areas required for installing and servicing the ATM.

Note 1: Increasing the area around the ATM will improve service access.

Note 2: The installation and service clearances in this section are the same as the minimum clearances for 5675 and 5875.

Coin Clearance

Clearance A - Coin DispenserThe illustration below shows the dimensions for an ATM with a coin dispenser fitted. Use this clearance in conjunction with the appropriate left-hand and right-hand device clearance.

192 mm

(7.56 in.)

645 mm

(25.39 in.)

703 mm

(27.68 in.)

551 mm

(21.69 in.)Coin DoorOpening

B006-6453-D000 27

Page 34: NCR Personas M Series 76 - Tranacttranact.com/wp-content/uploads/2011/09/P76-Site-Prep.pdf · arrival of the NCR Personas M Series 76 Automated ... Personas M Series 76 ATM Site Preparation

Personas M Series 76 ATM Site Preparation

Front Access Clearances

Top-box ClearancesThere are three conditions that need to be considered when installing the ATM within an enclosed area. These conditions are described below.

A If you are installing your ATM within the minimum clearance area with a normal ceiling height above the top-box, the ATM will operate at normal temperature.

B If you are installing your ATM within the minimum clearance area with a 58 mm (2.28 in.) clearance above the top-box, the maximum operating temperature will need to be reduced by 5°C (9°F).

C If you are installing your ATM within the minimum clearance area with a topper or enclosure that will sit directly on the top-box, a hot air extraction system will need to be installed. Any such system should be sourced locally. Refer to the illustration on page 29 for dimensions of the hot air output.

Note: For details of the ATM’s operating temperature range, refer to the Environmental and Planning Requirements (B006-6455) book.

58 mm

(2.28 in.)Top-box

A B C Hot AirOutput

28 B006-6453-D000

Page 35: NCR Personas M Series 76 - Tranacttranact.com/wp-content/uploads/2011/09/P76-Site-Prep.pdf · arrival of the NCR Personas M Series 76 Automated ... Personas M Series 76 ATM Site Preparation

Personas M Series 76 ATM Site Preparation

The illustration below shows the position of the hot air output on the rear of the ATM.

425 mm

(16.73 in.)

1347 mm

(53.03 in.)

90 mm

(3.54 in.)

150 mm

(5.91 in.)

Hot AirExtractionSystem

Hot Air Output

B006-6453-D000 29

Page 36: NCR Personas M Series 76 - Tranacttranact.com/wp-content/uploads/2011/09/P76-Site-Prep.pdf · arrival of the NCR Personas M Series 76 Automated ... Personas M Series 76 ATM Site Preparation

Personas M Series 76 ATM Site Preparation

Clearance B - Front Access UL or CEN L Security EnclosureThe illustration below shows the dimensions for an ATM configured with a UL or CEN Grade L security enclosure. For UL security enclosures, the currency dispenser or envelope depository can be fitted in the right-hand bay. For CEN Grade L security enclosures, the currency dispenser must be fitted in the left-hand bay.

Note: For low height ATMs, use this clearance only. The currency dispenser must be fitted in the right-hand bay.

UL CEN Grade LA Door opening angle 133.5° 136.5°

48 mm

(1.89 in.)

58 mm

(2.28 in.)

886 mm

(34.88 in.)

1281 mm

(50.43 in.)

770 mm

(30.31 in.)

2228 mm

(87.72 in.)

470 mm

(18.50 in.)488 mm

(19.21 in.)

838 mm

(32.99 in.)

1376 mm

(54.17 in.)

1339 mm

(52.72 in.)

A

Cur

renc

yD

ispe

nser

Env

elop

eD

epos

itory

30 B006-6453-D000

Page 37: NCR Personas M Series 76 - Tranacttranact.com/wp-content/uploads/2011/09/P76-Site-Prep.pdf · arrival of the NCR Personas M Series 76 Automated ... Personas M Series 76 ATM Site Preparation

Personas M Series 76 ATM Site Preparation

Clearance C - Front Access UL Security Enclosure

The illustration below shows the dimensions for an ATM configured with a UL security enclosure, and cash acceptor (UD686) in the left-hand bay.

48 mm

(1.89 in.)

58 mm

(2.28 in.)

886 mm

(34.88 in.)

1330 mm

(52.36 in.)

770 mm

(30.31 in.)

2228 mm

(87.72 in.)

470 mm

(18.50 in.)488 mm

(19.21 in.)

838 mm

(32.99 in.)

1376 mm

(54.17 in.)

1388 mm

(54.65 in.)

140º

Cas

hA

ccep

tor

(UD

686)

Cur

renc

yD

ispe

nser

B006-6453-D000 31

Page 38: NCR Personas M Series 76 - Tranacttranact.com/wp-content/uploads/2011/09/P76-Site-Prep.pdf · arrival of the NCR Personas M Series 76 Automated ... Personas M Series 76 ATM Site Preparation

Personas M Series 76 ATM Site Preparation

Clearance D - Front Access UL or CEN L Security EnclosureThe illustration below shows the dimensions for an ATM configured with a UL or CEN Grade L security enclosure, and cash acceptor or cash recycler in the right-hand bay.

UL CEN Grade LA Door opening angle 133.5° 136.5°

48 mm

(1.89 in.)

58 mm

(2.28 in.)

886 mm

(34.88 in.)

770 mm

(30.31 in.)

2228 mm

(87.72 in.)

470 mm

(18.50 in.)

300 mm

(11.81 in.)

488 mm

(19.21 in.)

838 mm

(32.99 in.)

1376 mm

(54.17 in.)

1639 mm

(64.53 in.)

1281 mm

(50.43 in.)

Cur

renc

yD

ispe

nser

Cas

hA

ccep

tor

orC

ash

Rec

ycle

r

A

32 B006-6453-D000

Page 39: NCR Personas M Series 76 - Tranacttranact.com/wp-content/uploads/2011/09/P76-Site-Prep.pdf · arrival of the NCR Personas M Series 76 Automated ... Personas M Series 76 ATM Site Preparation

Personas M Series 76 ATM Site Preparation

Clearance E - Front Access CEN III, CEN VDS or IV LGAI Security EnclosureThe illustration below shows the dimensions for an ATM configured with a CEN Grade III, CEN Grade VdS or CEN Grade IV LGAI security enclosure, and envelope depository in the right-hand bay.

48 mm

(1.89 in.)

58 mm

(2.28 in.)

140º

886 mm

(34.88 in.)

1422 mm

(55.98 in.)

1338 mm

(52.68 in.)

770 mm

(30.31 in.)

2228 mm

(87.72 in.)

470 mm

(18.50 in.)488 mm

(19.21 in.)

838 mm

(32.99 in.)

1320 mm

(51.97 in.)

Cur

renc

yD

ispe

nser

Env

elop

eD

epos

itory

B006-6453-D000 33

Page 40: NCR Personas M Series 76 - Tranacttranact.com/wp-content/uploads/2011/09/P76-Site-Prep.pdf · arrival of the NCR Personas M Series 76 Automated ... Personas M Series 76 ATM Site Preparation

Personas M Series 76 ATM Site Preparation

Clearance F - Front Access CEN III, CEN VDS or IV LGAI Security EnclosureThe illustration below shows the dimensions for an ATM configured with a CEN Grade III, CEN Grade VdS or CEN Grade IV LGAI security enclosure, and cash acceptor or cash recycler in the right-hand bay.

48 mm

(1.89 in.)

58 mm

(2.28 in.)

140º

886 mm

(34.88 in.)

1722 mm

(67.80 in.)

1338 mm

(52.68 in.)

770 mm

(30.31 in.)

2228 mm

(87.72 in.)

838 mm

(32.99 in.)

1320 mm

(51.97 in.)

470 mm

(18.50 in.)488 mm

(19.21 in.)

300 mm

(11.81 in.)

Cas

hA

ccep

tor

orC

ash

Rec

ycle

r

Cur

renc

yD

ispe

nser

34 B006-6453-D000

Page 41: NCR Personas M Series 76 - Tranacttranact.com/wp-content/uploads/2011/09/P76-Site-Prep.pdf · arrival of the NCR Personas M Series 76 Automated ... Personas M Series 76 ATM Site Preparation

Personas M Series 76 ATM Site Preparation

Rear Access Clearances (Freestanding)

Clearance G - Freestanding Rear Access UL or CEN L Security EnclosureThe illustration below shows the dimensions for an ATM configured with a UL or CEN Grade L security enclosure. For UL security enclosures, the currency dispenser or envelope depository can be fitted in the right-hand bay. For CEN Grade L security enclosures, the currency dispenser must be fitted in the left-hand bay.

UL CEN Grade LA Door opening angle 133.5° 136.5°

104 mm

(4.09 in.)

58 mm

(2.28 in.)

886 mm

(34.88 in.)

1339 mm

(52.72 in.)

1281 mm

(50.43 in.)770 mm

(30.31 in.)

3015 mm

(118.70 in.)

680 mm

(26.77 in.)

1626 mm

(64.02 in.)

375 mm

(14.76 in.)393 mm

(15.47 in.)

Env

elop

eD

epos

itory

Cur

renc

yD

ispe

nser

A

B006-6453-D000 35

Page 42: NCR Personas M Series 76 - Tranacttranact.com/wp-content/uploads/2011/09/P76-Site-Prep.pdf · arrival of the NCR Personas M Series 76 Automated ... Personas M Series 76 ATM Site Preparation

Personas M Series 76 ATM Site Preparation

Clearance H - Freestanding Rear Access UL Security EnclosureThe illustration below shows the dimensions for an ATM configured with a UL security enclosure, and cash acceptor (UD686) in the left-hand bay.

104 mm

(4.09 in.)

58 mm

(2.28 in.)

886 mm

(34.88 in.)

1388 mm

(54.65 in.)

1330 mm

(52.36 in.)770 mm

(30.31 in.)

3015 mm

(118.70 in.)

680 mm

(26.77 in.)

1626 mm

(64.02 in.)

375 mm

(14.76 in.)393 mm

(15.47 in.)

140º

Cur

renc

yD

ispe

nser

Cas

hA

ccep

tor

(UD

686)

36 B006-6453-D000

Page 43: NCR Personas M Series 76 - Tranacttranact.com/wp-content/uploads/2011/09/P76-Site-Prep.pdf · arrival of the NCR Personas M Series 76 Automated ... Personas M Series 76 ATM Site Preparation

Personas M Series 76 ATM Site Preparation

Clearance I - Freestanding Rear Access UL or CEN L Security EnclosureThe illustration below shows the dimensions for an ATM configured with a UL or CEN Grade L security enclosure, and cash acceptor or cash recycler in the right-hand bay.

UL CEN Grade LA Door opening angle 133.5° 136.5°

104 mm

(4.09 in.)

58 mm

(2.28 in.)

886 mm

(34.88 in.)

1639 mm

(64.53 in.)

1281 mm

(50.43 in.)

770 mm

(30.31 in.)

3015 mm

(118.70 in.)

680 mm

(26.77 in.)

1626 mm

(64.02 in.)

375 mm

(14.76 in.)393 mm

(15.47 in.)

300 mm

(11.81 in.)

Cur

renc

yD

ispe

nser

Cas

hA

ccep

tor

orC

ash

Rec

ycle

r

A

B006-6453-D000 37

Page 44: NCR Personas M Series 76 - Tranacttranact.com/wp-content/uploads/2011/09/P76-Site-Prep.pdf · arrival of the NCR Personas M Series 76 Automated ... Personas M Series 76 ATM Site Preparation

Personas M Series 76 ATM Site Preparation

Clearance J - Freestanding Rear Access CEN III, CEN VDS or IV LGAI Security EnclosureThe illustration below shows the dimensions for an ATM configured with a CEN Grade III, CEN Grade VdS or CEN Grade IV LGAI security enclosure, and envelope depository in the right-hand bay.

104 mm

(4.09 in.)

58 mm

(2.28 in.)

140º

886 mm

(34.88 in.)

1422 mm

(55.98 in.)

1338 mm

(52.68 in.)

770 mm

(30.31 in.)

3015 mm

(118.70 in.)

650 mm

(25.59 in.)

375 mm

(14.76 in.)393 mm

(15.47 in.)

1626 mm

(64.02 in.)

Env

elop

eD

epos

itory

Cur

renc

yD

ispe

nser

38 B006-6453-D000

Page 45: NCR Personas M Series 76 - Tranacttranact.com/wp-content/uploads/2011/09/P76-Site-Prep.pdf · arrival of the NCR Personas M Series 76 Automated ... Personas M Series 76 ATM Site Preparation

Personas M Series 76 ATM Site Preparation

Clearance K - Freestanding Rear Access CEN III, CEN VDS or IV LGAI Security EnclosureThe illustration below shows the dimensions for an ATM configured with a CEN Grade III, CEN Grade VdS or CEN Grade IV LGAI security enclosure, and cash acceptor or cash recycler in the right-hand bay.

104 mm

(4.09 in.)

58 mm

(2.28 in.)

140º

886 mm

(34.88 in.)

1722 mm

(67.80 in.)

1338 mm

(52.68 in.)

770 mm

(30.31 in.)

3015 mm

(118.70 in.)

650 mm

(25.59 in.)

1626 mm

(64.02 in.)

375 mm

(14.76 in.)393 mm

(15.47 in.)

300 mm

(11.81 in.)

Cur

renc

yD

ispe

nser

Cas

hA

ccep

tor

orC

ash

Rec

ycle

r

B006-6453-D000 39

Page 46: NCR Personas M Series 76 - Tranacttranact.com/wp-content/uploads/2011/09/P76-Site-Prep.pdf · arrival of the NCR Personas M Series 76 Automated ... Personas M Series 76 ATM Site Preparation

Personas M Series 76 ATM Site Preparation

Rear Access Clearances (Vestibule)

Clearance L - Vestibule Rear Access UL or CEN L Security EnclosureThe illustration below shows the dimensions for an ATM configured with a UL or CEN Grade L security enclosure. For UL security enclosures, the currency dispenser or envelope depository can be fitted in the right-hand bay. For CEN Grade L security enclosures, the currency dispenser must be fitted in the left-hand bay.

UL CEN Grade LA Door opening angle 133.5° 136.5°

104 mm

(4.09 in.)

58 mm

(2.28 in.)

1339 mm

(52.72 in.)

1281 mm

(50.43 in.)

770 mm

(30.31 in.)

680 mm

(26.77 in.)

324 mm

(12.76 in.)342 mm

(13.46 in.)

206 mm

(8.10 in.)

2253 mm

(88.70 in.)

488 mm

(19.21 in.)

915 mm

(36.02 in.)

Env

elop

eD

epos

itory

Cur

renc

yD

ispe

nser

A

Service AccessPosition

40 B006-6453-D000

Page 47: NCR Personas M Series 76 - Tranacttranact.com/wp-content/uploads/2011/09/P76-Site-Prep.pdf · arrival of the NCR Personas M Series 76 Automated ... Personas M Series 76 ATM Site Preparation

Personas M Series 76 ATM Site Preparation

Clearance M - Vestibule Rear Access UL Security EnclosureThe illustration below shows the dimensions for an ATM configured with a UL security enclosure, and cash acceptor (UD686) in the left-hand bay.

140º104 mm

(4.09 in.)

58 mm

(2.28 in.)

1388 mm

(54.65 in.)

1330 mm

(52.36 in.)

770 mm

(30.31 in.)

680 mm

(26.77 in.)

324 mm

(12.76 in.)342 mm

(13.46 in.)

206 mm

(8.10 in.)

2253 mm

(88.70 in.)

488 mm

(19.21 in.)

915 mm

(36.02 in.)

Cur

renc

yD

ispe

nser

Cas

hA

ccep

tor

(UD

686)

Service AccessPosition

B006-6453-D000 41

Page 48: NCR Personas M Series 76 - Tranacttranact.com/wp-content/uploads/2011/09/P76-Site-Prep.pdf · arrival of the NCR Personas M Series 76 Automated ... Personas M Series 76 ATM Site Preparation

Personas M Series 76 ATM Site Preparation

Clearance N - Vestibule Rear Access UL or CEN L Security EnclosureThe illustration below shows the dimensions for an ATM configured with a UL or CEN Grade L security enclosure, and cash acceptor or cash recycler in the right-hand bay.

UL CEN Grade LA Door opening angle 133.5° 136.5°

104 mm

(4.09 in.)

58 mm

(2.28 in.)

1639 mm

(64.53 in.)

1281 mm

(50.43 in.)

770 mm

(30.31 in.)

680 mm

(26.77 in.)

300 mm

(11.81 in.)

324 mm

(12.76 in.)342 mm

(13.46 in.)

206 mm

(8.10 in.)

2253 mm

(88.70 in.)

488 mm

(19.21 in.)

915 mm

(36.02 in.)

Cur

renc

yD

ispe

nser

Cas

hA

ccep

tor

orC

ash

Rec

ycle

r

A

Service AccessPosition

42 B006-6453-D000

Page 49: NCR Personas M Series 76 - Tranacttranact.com/wp-content/uploads/2011/09/P76-Site-Prep.pdf · arrival of the NCR Personas M Series 76 Automated ... Personas M Series 76 ATM Site Preparation

Personas M Series 76 ATM Site Preparation

Clearance O - Vestibule Rear Access CEN III, CEN VDS or IV LGAI Security EnclosureThe illustration below shows the dimensions for an ATM configured with a CEN Grade III, CEN Grade VdS or CEN Grade IV LGAI security enclosure, and envelope depository in the right-hand bay.

104 mm

(4.09 in.)

58 mm

(2.28 in.)

140º

1422 mm

(55.98 in.)

1338 mm

(52.68 in.)

770 mm

(30.31 in.)

650 mm

(25.59 in.)

324 mm

(12.76 in.)342 mm

(13.46 in.)

206 mm

(8.10 in.)

2253 mm

(88.70 in.)

488 mm

(19.21 in.)

915 mm

(36.02 in.)

Env

elop

eD

epos

itory

Cur

renc

yD

ispe

nser

Service AccessPosition

B006-6453-D000 43

Page 50: NCR Personas M Series 76 - Tranacttranact.com/wp-content/uploads/2011/09/P76-Site-Prep.pdf · arrival of the NCR Personas M Series 76 Automated ... Personas M Series 76 ATM Site Preparation

Personas M Series 76 ATM Site Preparation

Clearance P - Vestibule Rear Access CEN III, CEN VDS or IV LGAI Security EnclosureThe illustration below shows the dimensions for an ATM configured with a CEN Grade III, CEN Grade VdS or CEN Grade IV LGAI security enclosure, and cash acceptor or cash recycler in the right-hand bay.

104 mm

(4.09 in.)

58 mm

(2.28 in.)

140º

1722 mm

(67.80 in.)

1338 mm

(52.68 in.)

770 mm

(30.31 in.)

650 mm

(25.59 in.)

300 mm

(11.81 in.)

324 mm

(12.76 in.)342 mm

(13.46 in.)

2253 mm

(88.70 in.)

206 mm

(8.10 in.)

488 mm

(19.21 in.)

915 mm

(36.02 in.)

Cur

renc

yD

ispe

nser

Cas

hA

ccep

tor

orC

ash

Rec

ycle

r

Service AccessPosition

44 B006-6453-D000

Page 51: NCR Personas M Series 76 - Tranacttranact.com/wp-content/uploads/2011/09/P76-Site-Prep.pdf · arrival of the NCR Personas M Series 76 Automated ... Personas M Series 76 ATM Site Preparation

Personas M Series 76 ATM Site Preparation

Exterior Wall ClearancesThe illustrations below show the minimum clear wall area required around the collar for installation and servicing.

Standard Collar

Advert Collar

30 mm

(1.18 in.)30 mm

(1.18 in.)

152 mm

(5.98 in.)

152 mm

(5.98 in.)

30 mm

(1.18 in.)30 mm

(1.18 in.)

152 mm

(5.98 in.)

152 mm

(5.98 in.)

B006-6453-D000 45

Page 52: NCR Personas M Series 76 - Tranacttranact.com/wp-content/uploads/2011/09/P76-Site-Prep.pdf · arrival of the NCR Personas M Series 76 Automated ... Personas M Series 76 ATM Site Preparation

Personas M Series 76 ATM Site Preparation

HOLE IN THE WALLThe vestibule ATM can be installed through an existing NCR 5675 or 5875 hole in the wall with minimum rework required, depending on the ATM being replaced and wall thickness.Customised collars or surrounds made by the owning organisation may need rework or replacement due to the following installation requirements.The wall and floor need to be smooth and even as the collar has a tolerance of +/- 4 mm (0.16 in. (+/- 0.5°)) at the top and bottom, with 0 mm (0.00 in. (0 degrees)) at its centre. This is shown in the following illustration.

Note: The collar cannot accommodate large dips or depressions in the wall.

Installation CategoriesThe physical installation is divided into three categories.

1. A new installation of the vestibule ATM. See page 47.2. An installation where the vestibule ATM replaces a 5675. The hole in wall must be

modified. See page 48.3. An installation where the vestibule ATM replaces a 5875. The hole in wall must be

modified. See page 49.

+/- 4 mm

(0.16 in.)

+/- 4 mm

(0.16 in.)

0.0 mm

(0.00 in.)

46 B006-6453-D000

Page 53: NCR Personas M Series 76 - Tranacttranact.com/wp-content/uploads/2011/09/P76-Site-Prep.pdf · arrival of the NCR Personas M Series 76 Automated ... Personas M Series 76 ATM Site Preparation

Personas M Series 76 ATM Site Preparation

Installing Through a Glass WallIf you are installing your ATM through a glass wall you may require a suitable glass support (normally a steel collar) to sit between the ATM collar and the glass. The requirement for this support should be determined by the architect. If required, any such support should be sourced locally.

Installing Through a New Hole in the WallIt is the responsibility of the owning institution to ensure that the heights from the floor level to the facia items comply with any local regulations.The illustration below shows the dimensions for a new installation of the vestibule ATM.

830 mm

(32.68 in.)

987 mm

(38.86 in.)206 mm

(8.10 in.)Maximum Wall

Thickness

680 mm

(26.77 in.)

1667 mm

(65.63 in.)

Hole in Wall

and ATM BaseFloor Level

B006-6453-D000 47

Page 54: NCR Personas M Series 76 - Tranacttranact.com/wp-content/uploads/2011/09/P76-Site-Prep.pdf · arrival of the NCR Personas M Series 76 Automated ... Personas M Series 76 ATM Site Preparation

Personas M Series 76 ATM Site Preparation

Replacing 5675 with Modifications to Hole in WallIt is the responsibility of the owning institution to ensure that the heights from the floor level to the facia items comply with any local regulations.The illustration below shows the dimensions for replacing a 5675 vestibule ATM.

Note: The effective height of the hole in the wall is taller than the required height. To reduce the height, either rebuild part of the wall or use an advert collar.For advert collar dimensions, refer to Vestibule with Advert Collar on page 15.

830 mm

(32.68 in.)

1135 mm

(44.69 in.)See Note

987 mm

(38.86 in.)

195 mm

(7.68 in.)

152 mm

(6.00 in.)Wall Thickness

680 mm

(26.77 in.)

1815 mm

(71.46 in.)

Hole in Wall

and ATM BaseFloor Level

Remove Wall Section

Rebuild Wall Section

48 B006-6453-D000

Page 55: NCR Personas M Series 76 - Tranacttranact.com/wp-content/uploads/2011/09/P76-Site-Prep.pdf · arrival of the NCR Personas M Series 76 Automated ... Personas M Series 76 ATM Site Preparation

Personas M Series 76 ATM Site Preparation

Replacing 5875 with Modifications to Hole in WallIt is the responsibility of the owning institution to ensure that the heights from the floor level to the facia items comply with any local regulations.The illustration below shows the dimensions for replacing a 5875.

987 mm

(38.86 in.)

680 mm

(26.77 in.)

1667 mm

(65.63 in.)

152 mm

(6.00 in.)Wall Thickness

55 mm

(2.17 in.)

855 mm

(33.66 in.)

Hole in Wall

and ATM BaseFloor Level

Remove Wall Section

B006-6453-D000 49

Page 56: NCR Personas M Series 76 - Tranacttranact.com/wp-content/uploads/2011/09/P76-Site-Prep.pdf · arrival of the NCR Personas M Series 76 Automated ... Personas M Series 76 ATM Site Preparation

Personas M Series 76 ATM Site Preparation

REQUIREMENTS FOR THE FLOOR

Floor CoveringAn antistatic floor covering should be used and must be of a type that will not generate dust or fluff. The surface on which the ATM is to be sited should be level, smooth and even. In locations where the floor may be uneven, it is recommended that a steel plate is used under the ATM.

Floor LoadingThe ATM must be installed on a floor capable of supporting the maximum weight. Only the maximum weight should be considered as additional options may be added after installation.

Without Coin Dispenser

With Coin Dispenser (Empty of Coins)

UL CEN Grade L CEN Grade III, CEN Grade VdS or CEN Grade IV LGAI

Front and Rear Access

FrontAccess

RearAccess

FrontAccess

RearAccess

Maximum weight 848 kg (1869.8 lb.)

908 kg (2002.1 lb.)

908 kg (2002.1 lb.)

1023 kg (2255.7 lb.)

1023 kg (2255.7 lb.)

Floor loading 1376.6 kg/m2 (281.9 lb./ft2)

1523.5 kg/m2 (312.0 lb./ft2)

1474 kg/m2 (301.9 lb./ft2)

1716.5 kg/m2 (351.5 lb./ft2)

1660.7 kg/m2 (340.1 lb./ft2)

UL CEN Grade L CEN Grade III, CEN Grade VdS or CEN Grade IV LGAI

Front and Rear Access

FrontAccess

RearAccess

FrontAccess

RearAccess

Maximum weight 876 kg (1931.6 lb.)

936 kg (2063.9 lb.)

936 kg (2063.9 lb.)

1051 kg (2317.5 lb.)

1051 kg (2317.5 lb.)

Floor loading 1422.1 kg/m2 (291.2 lb./ft2)

1570.5 kg/m2 (321.6 lb./ft2)

1519.5 kg/m2 (311.2 lb./ft2)

1763.5 kg/m2 (361.2 lb./ft2)

1706.2 kg/m2 (349.4 lb./ft2)

50 B006-6453-D000

Page 57: NCR Personas M Series 76 - Tranacttranact.com/wp-content/uploads/2011/09/P76-Site-Prep.pdf · arrival of the NCR Personas M Series 76 Automated ... Personas M Series 76 ATM Site Preparation

Personas M Series 76 ATM Site Preparation

Bolt Holes LocationsThe following illustrations show a plan of the base of the ATM (viewed from above). The plans should be used for pre-drilling bolt holes and illustrates the design for the steel plate, if used.

Front Access

UL Security Enclosure Bolt Hole Locations The illustration below shows the dimensions for an ATM configured with a UL security enclosure.

Note: The boundary marked with an ‘B’ shows the cable access hole for all cables.

Standard Height Low HeightA 270 mm

(10.63 in.)420 mm

(16.54 in.)

285 mm

(11.22 in.)

179 mm

(7.05 in.)

384 mm

(15.12 in.)

800 mm

(31.50 in.)

32 mm

(1.26 in.)43 mm

(1.69 in.)

23 mm

(0.91 in.)

35 mm

(1.38 in.)

426 mm

(16.77 in.)

A

770 mm

(30.31 in.)

Ø 28 mm

(1.10 in.)

Front of ATM

B4 Places

B006-6453-D000 51

Page 58: NCR Personas M Series 76 - Tranacttranact.com/wp-content/uploads/2011/09/P76-Site-Prep.pdf · arrival of the NCR Personas M Series 76 Automated ... Personas M Series 76 ATM Site Preparation

Personas M Series 76 ATM Site Preparation

CEN Security Enclosure Bolt Hole Locations The illustration below shows the dimensions for an ATM configured with a CEN Grade L, CEN Grade III, CEN Grade VdS or CEN Grade IV LGAI security enclosure.

Note 1: The hole marked with a ‘B’ enables a security alarm sensor to be fitted.

Note 2: The boundary marked with a ‘C’ shows the cable access hole for all cables.

285 mm

(11.22 in.)

179 mm

(7.05 in.)

774 mm

(30.47 in.)

65 mm

(2.56 in.)

326 mm

(12.83 in.)426 mm

(16.77 in.)

270 mm

(10.63 in.)

770 mm

(30.31 in.)

x

28 mm

(1.10 in.)

60 mm

(2.36 in.)25 mm

(0.98 in.)x

28 mm

(1.10 in.)

45 mm

(1.77 in.)20 mm

(0.79 in.)

Ø

Ø

Ø

Ø

384 mm

(15.12 in.)

32 mm

(1.26 in.)

Front of ATM

B

C

B

A

A

A A

A

Counterbore DeepCounterbore Deep

52 B006-6453-D000

Page 59: NCR Personas M Series 76 - Tranacttranact.com/wp-content/uploads/2011/09/P76-Site-Prep.pdf · arrival of the NCR Personas M Series 76 Automated ... Personas M Series 76 ATM Site Preparation

Personas M Series 76 ATM Site Preparation

Rear Access

Freestanding UL Security Enclosure Bolt Hole Locations The illustration below shows the dimensions for an ATM configured with a UL security enclosure.

Note: The boundary marked with an ‘A’ shows the cable access hole for all cables.

285 mm

(11.22 in.)

234 mm

(9.21 in.)

800 mm

(31.50 in.)

43 mm

(1.69 in.)

23 mm

(0.91 in.)

35 mm

(1.38 in.)

426 mm

(16.77 in.)

270 mm

(10.63 in.)

770 mm

(30.31 in.)

Ø 28 mm

(1.10 in.)

384 mm

(15.12 in.)

32 mm

(1.26 in.)

Front of ATM

A

4 Places

B006-6453-D000 53

Page 60: NCR Personas M Series 76 - Tranacttranact.com/wp-content/uploads/2011/09/P76-Site-Prep.pdf · arrival of the NCR Personas M Series 76 Automated ... Personas M Series 76 ATM Site Preparation

Personas M Series 76 ATM Site Preparation

Vestibule UL Security Enclosure Bolt Hole Locations The illustration below shows the dimensions for an ATM configured with a UL security enclosure.

Note: The boundary marked with an ‘A’ shows the cable access hole for all cables.

285 mm

(11.22 in.)

234 mm

(9.21 in.)

43 mm

(1.69 in.)

23 mm

(0.91 in.)

35 mm

(1.38 in.)

426 mm

(16.77 in.)

270 mm

(10.63 in.)

770 mm

(30.31 in.)

Ø 28 mm

(1.10 in.)

384 mm

(15.12 in.)

32 mm

(1.26 in.)

800 mm

(31.50 in.)

206 mm

(8.10 in.)

359 mm

(14.13 in.)

Front of ATM

A

4 Places

ATM and Hole in WallMaximum

Wall Thickness

54 B006-6453-D000

Page 61: NCR Personas M Series 76 - Tranacttranact.com/wp-content/uploads/2011/09/P76-Site-Prep.pdf · arrival of the NCR Personas M Series 76 Automated ... Personas M Series 76 ATM Site Preparation

Personas M Series 76 ATM Site Preparation

Freestanding CEN Security Enclosure Bolt Hole Locations The illustration below shows the dimensions for an ATM configured with a CEN Grade L, CEN Grade III, CEN Grade VdS or CEN Grade IV LGAI security enclosure.

Note 1: The hole marked with a ‘B’ enables a security alarm sensor to be fitted.

Note 2: The boundary marked with a ‘C’ shows the cable access hole for all cables.

x

28 mm

(1.10 in.)

60 mm

(2.36 in.)25 mm

(0.98 in.)x

28 mm

(1.10 in.)

45 mm

(1.77 in.)20 mm

(0.79 in.)

285 mm

(11.22 in.)134 mm

(5.28 in.)

800 mm

(31.50 in.)

65 mm

(2.56 in.)

426 mm

(16.77 in.)

234 mm

(9.21 in.)

270 mm

(10.63 in.)

770 mm

(30.31 in.)

Ø

Ø

Ø

Ø

384 mm

(15.12 in.)

32 mm

(1.26 in.)

Counterbore DeepCounterbore Deep

Front of ATM

B

B

A

A

A A

A

C

B006-6453-D000 55

Page 62: NCR Personas M Series 76 - Tranacttranact.com/wp-content/uploads/2011/09/P76-Site-Prep.pdf · arrival of the NCR Personas M Series 76 Automated ... Personas M Series 76 ATM Site Preparation

Personas M Series 76 ATM Site Preparation

Vestibule CEN Security Enclosure Bolt Hole Locations The illustration below shows the dimensions for an ATM configured with a CEN Grade L, CEN Grade III, CEN Grade VdS or CEN Grade IV LGAI security enclosure.

Note 1: The hole marked with a ‘B’ enables a security alarm sensor to be fitted.

Note 2: The boundary marked with a ‘C’ shows the cable access hole for all cables.

x

28 mm

(1.10 in.)

60 mm

(2.36 in.)25 mm

(0.98 in.)x

28 mm

(1.10 in.)

45 mm

(1.77 in.)20 mm

(0.79 in.)

285 mm

(11.22 in.)134 mm

(5.28 in.)

65 mm

(2.56 in.)

426 mm

(16.77 in.)

234 mm

(9.21 in.)

270 mm

(10.63 in.)

770 mm

(30.31 in.)

Ø

Ø

Ø

Ø

384 mm

(15.12 in.)

32 mm

(1.26 in.)

800 mm

(31.50 in.)

206 mm

(8.10 in.)

359 mm

(14.13 in.)

Counterbore DeepCounterbore Deep

Front of ATM

B

B

A

A

A A

A

C

ATM and Hole in WallMaximum

Wall Thickness

56 B006-6453-D000

Page 63: NCR Personas M Series 76 - Tranacttranact.com/wp-content/uploads/2011/09/P76-Site-Prep.pdf · arrival of the NCR Personas M Series 76 Automated ... Personas M Series 76 ATM Site Preparation

Personas M Series 76 ATM Site Preparation

Security Bolts The ATM should be bolted to the floor, through the ‘A’ holes, using four bolts with anchor washers. The floor must be capable of withstanding the loading imposed by the anchor points for the bolts. The bolts and anchors must be supplied by the owning organisation.The minimum specification for bolts, to secure the ATM through any security enclosure to a concrete floor, is high tensile M16 bolts with appropriate anchor washers of 6 mm (0.24 in.) minimum thickness. It is recommended that these bolts be a minimum depth of 150 mm (5.91 in.) and that either resin anchor bolts or rawl type bolts are used.

Note 1: Bolting of CEN security enclosures should comply with the requirements of EN 1143-1 (CEN Safe Burglary Standard).

Note 2: For CEN security enclosures, the centre bolt hole ‘B’ in the floor is counterbored to a larger diameter than the other four. This enables a security alarm sensor to be fitted through the hole.

B006-6453-D000 57

Page 64: NCR Personas M Series 76 - Tranacttranact.com/wp-content/uploads/2011/09/P76-Site-Prep.pdf · arrival of the NCR Personas M Series 76 Automated ... Personas M Series 76 ATM Site Preparation

Personas M Series 76 ATM Site Preparation

VIDEO CAMERA

Ambient LightingIf the ATM is fitted with a video camera, it is strongly recommended that there is a minimum of 50 LUX lighting at floor level within the area illustrated below. This lighting level conforms to:● Australian Standard for Automatic Teller Machines (1990)● Lighting for Automatic Teller Machines as prepared by Illuminating Engineering

Society of North America (1997).

1500 mm

(59.06 in.)

1000 mm

(39.37 in.)

58 B006-6453-D000

Page 65: NCR Personas M Series 76 - Tranacttranact.com/wp-content/uploads/2011/09/P76-Site-Prep.pdf · arrival of the NCR Personas M Series 76 Automated ... Personas M Series 76 ATM Site Preparation

Personas M Series 76 ATM Site Preparation

Internal Space Constraint for Fitting a Third-Party Video Camera

The ATM can be ordered with a video camera in either PAL or NTSC format. However, if a camera is not configured and a third party video camera is to be installed, there is a space constraint to consider. The following illustration shows the space constraint dimensions.A list of cameras that will fit within this space constraint can be found in the ATMs Feature Descriptions (B006-6451) book.

72 mm

(2.83 in.)

24 mm

(0.94 in.)

190 mm

(7.48 in.)

100 mm

(3.94 in.)

67 mm

(2.64 in.)

18 mm

(0.71 in.)

10 mm

(0.39 in.)35 mm

(1.38 in.)

CameraFront

B006-6453-D000 59

Page 66: NCR Personas M Series 76 - Tranacttranact.com/wp-content/uploads/2011/09/P76-Site-Prep.pdf · arrival of the NCR Personas M Series 76 Automated ... Personas M Series 76 ATM Site Preparation

Personas M Series 76 ATM Site Preparation

60 B006-6453-D000

Page 67: NCR Personas M Series 76 - Tranacttranact.com/wp-content/uploads/2011/09/P76-Site-Prep.pdf · arrival of the NCR Personas M Series 76 Automated ... Personas M Series 76 ATM Site Preparation
Page 68: NCR Personas M Series 76 - Tranacttranact.com/wp-content/uploads/2011/09/P76-Site-Prep.pdf · arrival of the NCR Personas M Series 76 Automated ... Personas M Series 76 ATM Site Preparation

To help NCR maintain the quality of their publications, send comments on the accuracy, clarity, usability, navigation, organization, and value of this book.

Address correspondence to:

Surface mail address:

NCR Financial Solutions Group LtdInformation SolutionsKingsway WestDundeeScotlandDD2 3XX

Email address:

[email protected]