new sampling/sensor initiative (nessi) cpac: november 5, 2001 nessi (new sampling/sensor initiative)...

12
New Sampling/Sensor Initiative (NeSSI) New Sampling/Sensor Initiative (NeSSI) CPAC: November 5, 2001 NeSSI NeSSI (Ne (Ne w w S S ampling/ ampling/ S S ensor ensor I I nitiative nitiative ) ) Interface to the Interface to the Process Process Jim Tatera, Rob Dubois, Peter van Vuuren 2001 Fall Sponsor Meeting Center for Process Analytical Chemistry

Post on 19-Dec-2015

219 views

Category:

Documents


2 download

TRANSCRIPT

New Sampling/Sensor Initiative (NeSSI)New Sampling/Sensor Initiative (NeSSI) CPAC: November 5, 2001

NeSSINeSSI(Ne(Neww S Sampling/ampling/SSensorensor I Initiativenitiative))

Interface to the Interface to the ProcessProcess

Jim Tatera, Rob Dubois, Peter van Vuuren

2001 Fall Sponsor Meeting

Center for Process Analytical Chemistry

New Sampling/Sensor Initiative (NeSSI)New Sampling/Sensor Initiative (NeSSI) CPAC: November 5, 2001

TopicsTopics

• Major Goals of NeSSIMajor Goals of NeSSI

• Status and Developments to DataStatus and Developments to Data

• New NeSSI Analytical SensorsNew NeSSI Analytical Sensors

• Opportunities and Future NeedsOpportunities and Future Needs

• Facilitate the acceptance/implementation of...Facilitate the acceptance/implementation of...– modular, miniature & smartmodular, miniature & smart sample system technology sample system technology

– based on ISA SP76 standardization workbased on ISA SP76 standardization work

• Promote the concept of...Promote the concept of...– field-mountedfield-mounted smart sampling/analytical systems smart sampling/analytical systems

– integrationintegration of sample systems with physical/chemical sensors of sample systems with physical/chemical sensors

• Lay the groundwork for...Lay the groundwork for...– open connectivityopen connectivity architecture for sensor communications (e.g. architecture for sensor communications (e.g.

Ethernet, DeviceNet, etc.)Ethernet, DeviceNet, etc.)

– industry standard communicationindustry standard communication protocols (e.g. OPC, DeviceNet, CAN protocols (e.g. OPC, DeviceNet, CAN etc.)etc.)

– web enabledweb enabled technologies (e.g. Browser based HMI) technologies (e.g. Browser based HMI)

• Provide a technology bridge to the process for...Provide a technology bridge to the process for...– ““sensor/lab-on-a-chip”sensor/lab-on-a-chip” micro-analytical devices micro-analytical devices

– match the match the macro-worldmacro-world of process with of process with micro-worldmicro-world of of sensorsensor

Major Goals ofMajor Goals of

New Sampling/Sensor Initiative (NeSSI)New Sampling/Sensor Initiative (NeSSI) CPAC: November 5, 2001

Status and Developments to DateStatus and Developments to Date

• Integration of Physical Sensors Initial Main Goal (NeSSI I)Integration of Physical Sensors Initial Main Goal (NeSSI I)Pressure and Temp sensors readily availablePressure and Temp sensors readily availableTraditional Mass Flow Sensors availableTraditional Mass Flow Sensors available

(area classification limitations, high cost)(area classification limitations, high cost)

• First Generation of NeSSI Analytical Sensors EmergingFirst Generation of NeSSI Analytical Sensors Emerging(Announced at ISA2001 NeSSI Tutorial)(Announced at ISA2001 NeSSI Tutorial)

pH Sensor pH Sensor - Rosemount Analytical- Rosemount Analytical(demo to be presented during reception this (demo to be presented during reception this

evening)evening)

Moisture SensorMoisture Sensor - Panametrics - Panametrics

Oxygen SensorOxygen Sensor

UV/VIS ProbeUV/VIS Probe - Applied Analytics- Applied Analytics

New Sampling/Sensor Initiative (NeSSI)New Sampling/Sensor Initiative (NeSSI) CPAC: November 5, 2001

First pH SensorFirst pH Sensor

Courtesy of Rosemount Analytical

New

New Sampling/Sensor Initiative (NeSSI)New Sampling/Sensor Initiative (NeSSI) CPAC: November 5, 2001

First OFirst O22 Sensor Sensor

Courtesy of Panametrics & Swagelok Co.

New

New Sampling/Sensor Initiative (NeSSI)New Sampling/Sensor Initiative (NeSSI) CPAC: November 5, 2001

First NeSSI HFirst NeSSI H22O ProbeO Probe

Courtesy of Panametrics & Swagelok Co.

New

New Sampling/Sensor Initiative (NeSSI)New Sampling/Sensor Initiative (NeSSI) CPAC: November 5, 2001

First UV/VIS Optical CellFirst UV/VIS Optical Cell

Courtesy of Applied Analytics, Inc.

New

New Sampling/Sensor Initiative (NeSSI)New Sampling/Sensor Initiative (NeSSI) CPAC: November 5, 2001

Mass Flow ControllerMass Flow Controller

Courtesy of Porter Instruments and the Swagelok Co.

New

New Sampling/Sensor Initiative (NeSSI)New Sampling/Sensor Initiative (NeSSI) CPAC: November 5, 2001

Opportunities and Future NeedsOpportunities and Future Needs

• Application of Smart Miniature Physical SensorsApplication of Smart Miniature Physical Sensors(Next Main Goal NeSSI II - Update this afternoon)(Next Main Goal NeSSI II - Update this afternoon)

Extend to pressure, temp and flow sensors (gas and Extend to pressure, temp and flow sensors (gas and liquid) liquid)

Small FootprintSmall Footprint

Intrinsically SafeIntrinsically Safe

CAN-basedCAN-based

“Flash” configurable for multiple protocols: e.g. DeviceNet and SDS“Flash” configurable for multiple protocols: e.g. DeviceNet and SDS

Integrate with SAMIntegrate with SAM

Cost: <$500Cost: <$500

(believe technology is available and “waiting in wings”(believe technology is available and “waiting in wings” needs adaptation to NeSSI footprint) needs adaptation to NeSSI footprint)

Joint CPAC/End-User/Vendor Program for 2002?Joint CPAC/End-User/Vendor Program for 2002?

New Sampling/Sensor Initiative (NeSSI)New Sampling/Sensor Initiative (NeSSI) CPAC: November 5, 2001

Opportunities and Future NeedsOpportunities and Future Needs

• Adaptation/Integration of Next Generation Micro-Adaptation/Integration of Next Generation Micro-Analytical Systems with NeSSI as Sampling System Analytical Systems with NeSSI as Sampling System PlatformPlatform

Applicability: ALSO FOR LAB BASED (OFF-LINE) Applicability: ALSO FOR LAB BASED (OFF-LINE) APPLICATIONSAPPLICATIONS

Candidates:Candidates:

Micro - GC Micro - GC Micro NMR Micro NMR Micro MSMicro MS “Lab-on-a-Chip”“Lab-on-a-Chip”OthersOthers

Issue: How do we evaluate/test NeSSI as Micro-Issue: How do we evaluate/test NeSSI as Micro-Analytical Sampling System Platform?Analytical Sampling System Platform?

Topic for Focus Group Discussion?Topic for Focus Group Discussion?

New Sampling/Sensor Initiative (NeSSI)New Sampling/Sensor Initiative (NeSSI) CPAC: November 5, 2001

FINIFINI