new wheelchair control interface systems
TRANSCRIPT
![Page 1: New Wheelchair Control Interface Systems](https://reader030.vdocument.in/reader030/viewer/2022021610/620a8320f8422861431f2120/html5/thumbnails/1.jpg)
New Wheelchair Control Interface Systems
John Batchelor, Osman Rakibet, Robert Horne and Stephen Kelly
School of Engineering and Digital Arts
![Page 2: New Wheelchair Control Interface Systems](https://reader030.vdocument.in/reader030/viewer/2022021610/620a8320f8422861431f2120/html5/thumbnails/2.jpg)
Outline
• SYSIASS Project
• Wheel chair interface:
Resistopalatography
RFID
Epidermal Electronics
Tongue Proximity Sensor
Page 2
![Page 3: New Wheelchair Control Interface Systems](https://reader030.vdocument.in/reader030/viewer/2022021610/620a8320f8422861431f2120/html5/thumbnails/3.jpg)
Passive Assistive Technology with Dignity
Page 3
Assisted Living (SYSIASS project)
The intention is to produce wheelchair control assistive
technology that is not obtrusive or functional looking.
This work involves Kent, Essex
& Lille Universities together with
East Kent Hospitals University
NHS Foundation Trust and
Groupe Hospitalier de l’Insitut
Catholique de Lille.
![Page 4: New Wheelchair Control Interface Systems](https://reader030.vdocument.in/reader030/viewer/2022021610/620a8320f8422861431f2120/html5/thumbnails/4.jpg)
Resistopalatography:
Page 4
• Utilises tongue pressure against the hard palate to control either a computer
or a wheelchair.
• Consists of a force sensing resistor array that can be mounted onto a
standard dental retainer plate.
• Capable of measuring light pressure impacts and full force swipes.
• The large range between full and no
pressure offers opportunity to cater for
widely differing user strengths.
• Sensed output is amplified & digitized.
• The array of values is processed to
calculate required (x, y) control input.
• Desired speed can be derived from the
force applied.
![Page 5: New Wheelchair Control Interface Systems](https://reader030.vdocument.in/reader030/viewer/2022021610/620a8320f8422861431f2120/html5/thumbnails/5.jpg)
Resistopalatography Measurements:
Page 5
• The control system has been implemented and tested on a powered chair.
• Position measurements were obtained using an optical motion capture system.
• Currently 64/128 sensors are
implemented in the array.
• More sensors could be activated to
improve resolution.
• Other uses for the system include:
• Diagnostic Tool for Speech and
Language Therapy allowing for
tongue palatal contact to be
observed.
• Diagnostic analysis of
dysphagia by measuring tongue
force during swallowing.
![Page 6: New Wheelchair Control Interface Systems](https://reader030.vdocument.in/reader030/viewer/2022021610/620a8320f8422861431f2120/html5/thumbnails/6.jpg)
• Stock control
• Transport
• Anti-theft
• Anti-counterfeiting
• HCI for:
Healthcare
Assisted Living
Page 6
Body-Centric RFID Tagging and Sensing RFID is conventionally used in asset tracking, but it is finding new applications.
Most people are familiar with RFID as near field (smart card or contactless
payment) technology at 13.56MHz.
![Page 7: New Wheelchair Control Interface Systems](https://reader030.vdocument.in/reader030/viewer/2022021610/620a8320f8422861431f2120/html5/thumbnails/7.jpg)
UHF RFID
• Works like RADAR
• Energised by reader signal
• Tag reflects modulated information back to reader
• No battery needed at the tag (Passive System)
Tag switch
Reader
antenna
Page 7
This work involves UHF RFID (860-920MHz)
In favourable conditions (no people around) read ranges of 7m+ can be achieved.
![Page 8: New Wheelchair Control Interface Systems](https://reader030.vdocument.in/reader030/viewer/2022021610/620a8320f8422861431f2120/html5/thumbnails/8.jpg)
Eye Blink Sensing as Human-Computer Interface
Page 8
E-make up has been demonstrated to
control interfaces including a wheelchair.
K. Vega and H. Fuks, ‘Beauty Technology as an Interactive Computing Platform’, ITS
'13 Proceedings of the 2013 ACM international conference on Interactive tabletops
and surfaces, Pages 357-360, New York, NY, USA.
K. Vega and H. Fuks K. Vega and H. Fuks
![Page 10: New Wheelchair Control Interface Systems](https://reader030.vdocument.in/reader030/viewer/2022021610/620a8320f8422861431f2120/html5/thumbnails/10.jpg)
Inkjet printing of transfer tattoo tags
Page 10
Research grant money has developed flexible conducting transfers:
![Page 11: New Wheelchair Control Interface Systems](https://reader030.vdocument.in/reader030/viewer/2022021610/620a8320f8422861431f2120/html5/thumbnails/11.jpg)
Tag Surface Current
The slot provides an impedance transformation between the antenna
terminals and the complex impedance of the transponder chip.
The tag becomes mis-matched when the slot conditions change
(the energy entering the tag is reduced).
This means more power is required at the reader to activate the tag.
Page 11
Energy concentrates here
![Page 12: New Wheelchair Control Interface Systems](https://reader030.vdocument.in/reader030/viewer/2022021610/620a8320f8422861431f2120/html5/thumbnails/12.jpg)
Making RFID Tags Sense
Page 12
Efficient tag operation is highly dependent on the impedance match between the
transponder electronics and the antenna input.
This is done using a nested slotline input transformer with dimensions l and w.
![Page 13: New Wheelchair Control Interface Systems](https://reader030.vdocument.in/reader030/viewer/2022021610/620a8320f8422861431f2120/html5/thumbnails/13.jpg)
Predicted Read Range
Tag maximum read range
where EIRP is reader power and
depends on the tag impedance
match
PIC is the transponder activation power.
Page 13
![Page 14: New Wheelchair Control Interface Systems](https://reader030.vdocument.in/reader030/viewer/2022021610/620a8320f8422861431f2120/html5/thumbnails/14.jpg)
• on the tongue
An RFID Switch to Control Wheelchairs
Page 14
The in-mouth technology is intended to be disposable and
straightforward to fit onto a dental plate.
A tag was tested to work :
There is one small chip and no
battery required inside the mouth.
• Inside the mouth
• With the mouth closed
![Page 15: New Wheelchair Control Interface Systems](https://reader030.vdocument.in/reader030/viewer/2022021610/620a8320f8422861431f2120/html5/thumbnails/15.jpg)
Reduced Size Mouth Mounted RFID Switch Design
Page 15
a
b
c
d
Read range for in mouth tag = 1m
![Page 16: New Wheelchair Control Interface Systems](https://reader030.vdocument.in/reader030/viewer/2022021610/620a8320f8422861431f2120/html5/thumbnails/16.jpg)
Measurements with mouth open:
Mouth Mounted RFID Switch Design
Page 16
0
1
2
3
4
5
6
0 5 10 15 20 25 30
Tra
nsm
itte
d P
ow
er
(dB
m)
at
900M
Hz
Tongue / tag separation (mm)
ON
OFF
5dB
range is
ola
tion b
etw
een O
N a
nd O
FF
Pro
xim
ity s
en
sin
g
range
![Page 17: New Wheelchair Control Interface Systems](https://reader030.vdocument.in/reader030/viewer/2022021610/620a8320f8422861431f2120/html5/thumbnails/17.jpg)
A simple homogeneous flesh model of the hard palate and tongue
was created. εr = 55 and conductivity σ = 0.94 S/m.
Reduced Size Mouth Mounted RFID Switch Simulation
Page 17
0
1
2
3
4
5
0
1
2
3
4
5
0 10 20 30
Tongue – Tag Separation Distance (mm)
Measurement Simulation
The effective tongue capacitance was
simulated for various tongue-tag
separations.
Tag p
ow
er
respon
se (
dB
)
![Page 18: New Wheelchair Control Interface Systems](https://reader030.vdocument.in/reader030/viewer/2022021610/620a8320f8422861431f2120/html5/thumbnails/18.jpg)
A more accurate 3D mouth model was used for the simulation.
Improved Modelling
Page 18
0
0.3
0.6
0.9
1.2
1.5
1.8
0
1
2
3
4
5
6
7
0 5 10 15 20 25 30 35
Tongue-Tag Separation Distance (mm)
Measurement Simulation
Tag p
ow
er
respon
se (
dB
)
Measured results averaged over 3 users.
![Page 19: New Wheelchair Control Interface Systems](https://reader030.vdocument.in/reader030/viewer/2022021610/620a8320f8422861431f2120/html5/thumbnails/19.jpg)
0
1
2
3
4
5
6
7
8
0 1 2 3 4 5 6 7 8
Avera
ge E
rror
Magnitude (
%)
Measurement Number
The 3 users were asked to hit all 5 targets and were given 7 attempts at each.
The average for all 3 users for all 5 targets was individually found for attempts
1 to 7.
The percentage error E was calculated for each attempt:
User Improvements with Practice
Page 19
The average errors were
observed to halve after 5
attempts, and to drop to
about 1% by 7 attempts.
𝐸 =𝑇𝑎𝑟𝑔𝑒𝑡𝑚𝑒𝑎𝑠𝑢𝑟𝑒𝑑 − 𝑇𝑎𝑟𝑔𝑒𝑡𝑒𝑥𝑝𝑒𝑐𝑡𝑒𝑑
𝑇𝑎𝑟𝑔𝑒𝑡𝑒𝑥𝑝𝑒𝑐𝑡𝑒𝑑× 100%
![Page 20: New Wheelchair Control Interface Systems](https://reader030.vdocument.in/reader030/viewer/2022021610/620a8320f8422861431f2120/html5/thumbnails/20.jpg)
Finally, the 3 users were asked to hit the 5 targets in a random sequence of
25 attempts.
The graphs show the distribution around the required target when (a) all 25
attempts are included and (b) when only the final 13 attempts are considered.
Hitting Random Targets
Page 20
0.5
0.6
0.7
0.8
0.9
1
0.5 0.6 0.7 0.8 0.9 1
Mea
sure
d R
ead
Ran
ge
(m)
Measured Read Range (m)
0.5
0.6
0.7
0.8
0.9
1
0.5 0.6 0.7 0.8 0.9 1
Mea
sure
d R
ead
Ran
ge
(m)
Measured Read Range (m)
(a) (b)
Overlap is observed in (a) meaning there is confusion between the targets.
However, by allowing some practice time and only considering the second half of
the measurement, in (b) each target is now clearly discriminated.
![Page 21: New Wheelchair Control Interface Systems](https://reader030.vdocument.in/reader030/viewer/2022021610/620a8320f8422861431f2120/html5/thumbnails/21.jpg)
The Next Stage
A target selection algorithm will be developed.
The extent of confusion between targets must be
investigated.
An interface to the chair control must be implemented.
A second direction control should be added.
Page 21
![Page 22: New Wheelchair Control Interface Systems](https://reader030.vdocument.in/reader030/viewer/2022021610/620a8320f8422861431f2120/html5/thumbnails/22.jpg)
Summary
• Future work will establish if multi-vector
switches can be fitted for joystick/mouse
control.
• Integrated sensing function has been
demonstrated for tongue control
• Skin mountable RFID/Antennas have been
developed for muscle twitch control
Page 22