non electric detonator sheet products/detonator v0617 warning enaex services s.a. is responsible...
TRANSCRIPT
TRANSPORT INFORMATION
B
Data Sheet Products/DetonatorV0617
WARNINGENAEX SERVICES S.A. is responsible only as expressly stated in this catalog, in shall in no event be liable for damages, losses or any contingency arising from the use of the products, except those expressly indicated by the current Chilean legislation. The use of explosives is regulated in each country by its own laws. ENAEX SERVICES S.A. reserves the right to introduce to its products all those changes deemed appropriate without prior notice.
Non Electric Detonator
DESCRIPTION
It consists of a shock tube, with a length determined by the blast
design, to a high power detonator and delay period to initiate the
explosive charge. The other end of the the shock tube is sealed
and has a Cobra type plastic connector with a sticker indicating
the number of the delay.
CHARACTERISTICS
• A high power detonator.
• Blue "Cobra" type plastic connector.
• White numbered sticker label on the shock tube.
• YELLOW shock tube, with a minimum break load of 25 kg.
• Resistant to high and low temperatures, oil resistant in ANFO for 4
days at 40 ° C, water resistant.
• Reliable initiator for ANFO, APD Booster, cartridged explosives and
high explosives sensitive to blasting caps.
• The initiation signal propagates in the tube through folds, curves,
knots and ligatures.
• The shock tube remains intact after use.
(Note: As a rough guideline, for every 2 m shock tube used in the
assembly, add 1 ms to the nominal delay period of the detonator.)
Assembled Detonator, Non Electric
Class 1.1 B
NU: 0360
HDS-DET-01
INITIATION
Enaex non-electric detonators can be initiated with any of the
products listed below:
• Electric detonators.
• Electronic detonators.
• Detonating cords (minimum 3g PETN/m)
• Trunkline delay.
PACKAGING
• Box dimensions: 560 x 290 x 260 (mm x mm x mm)
• Gross weight of the box: 18.9 Kg
• Net weight of the box: 18.0 Kg
* For other lengths, consult with Enaex Services
PRODUCT RANGE
LENGTH OF THE SHOCK TUBES
The minimum length is 2.4 m. and maximum of 30.4 m.
BENEFITS
• Suitable pyrotechnic delay accuracy.
• Robust shock tube, abrasive resistant and does not get entangled.
• Its use is easy and simple.
• Highly visible components.
• Economic, reduced inventory.
• Reliable.
• Low noise levels.
Length (m)
2.4
3.0 – 3.6 - 4,2
4.8 – 5.5
6.0
9.0 – 10.0 – 12.2
15.2
16.0 -18.0 – 20.0
24.4
30.4
Units / Box
300
250
200
150
100
90
70
60
50
Data Sheet Products/DetonatorV0617
WARNINGENAEX SERVICES S.A. is responsible only as expressly stated in this catalog, in shall in no event be liable for damages, losses or any contingency arising from the use of the products, except those expressly indicated by the current Chilean legislation. The use of explosives is regulated in each country by its own laws. ENAEX SERVICES S.A. reserves the right to introduce to its products all those changes deemed appropriate without prior notice.
Non Electric Detonator
DELAYS DELAYS
SERIES MS SERIES MS
No. ms SERIES No. ms SERIES
0
1
2
3
4
5
0
25
50
75
100
125
MS
MS
MS
MS
MS
MS
28
29
30
31
32
33
4600
5500
6400
7400
8500
9600
LP
LP
LP
LP
LP
LP
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
150
175
200
250
300
350
400
450
500
600
700
800
900
1000
1100
1200
1300
1400
1800
2400
3000
3800
MS
MS
MS
MS
MS
MS
MS
MS
MS
MS
MS
MS
MS
MS LP
MS
MS
MS
MS LP
LP
LP
LP
LP
SAFETY
The shock tube can not be initiated by:
• Radio frequency transmissions.
• Radiations.
• Parasite or stray currents.
• Electrostatic discharge.
• Burning / heat / friction.
STORAGE
• Store in an appropriate, cool, dry place.
• Store in an appropriate place, with low humidity and good ventilation.
• Comply with legal requirements concerning the storage of yourlocation.
• The shelf life is 36 months from the date of manufacture.
• Temperatures above 90 ° C can cause spontaneous explosions.
• Always rotate stock ( st in, st out).
Data Sheet Products/DetonatorV0617
WARNINGENAEX SERVICES S.A. is responsible only as expressly stated in this catalog, in shall in no event be liable for damages, losses or any contingency arising from the use of the products, except those expressly indicated by the current Chilean legislation. The use of explosives is regulated in each country by its own laws. ENAEX SERVICES S.A. reserves the right to introduce to its products all those changes deemed appropriate without prior notice.
Non Electric Detonator
APPLICATIONS
Enaex non-electric detonators are used in surface and underground
mining and civil works.
SPECIAL PRECAUTIONS
• Hand with care. Damage to connector or tube can lead to failure
initiation.
• Always keep the detonators pointing in your opposite direction.
• Severe impacts on the detonator may result in a premature
detonation.
• Never pull, stretch or twist the shock tube.
• Never connect the blast or shot before completing the loading
operations and personnel in the area has been evacuated.
LIMITS OF LIABILITY
This information summarizes the product's capabilities to the best
knowledge at the date of issue. Each user must st check the
technical data sheet and in the context of how it Intends to use the
product. For additional information on this product and storage,
please contact Enaex through your service and / or supply
administrator to the telephone : +56 2 28377777, or email: