not to scale @a3 artist impression subm ion a rt ismp …

12
CLIENT SIGNATURE DATE 19060 Sheet No.: Scale: Status: Plot Date: Project No: Drawing Title: Project Name Client COMMUNITY FACILITY REV DATE AMENDMENT 24/9/20 /Volumes/Data/03 ARCHIVED PROJECTS/2019/19060 WALCHA MENS SHED/19060_sk2.pln @ A3 SUBMISSION WD1 DRAWING SCHEDULE 172W FITZROY STREET WALCHA NSW 2354 WALCHA MEN'S SHED DT 5 15 20 25 50 75 10 length in millimeters at full size 100 5 15 20 25 50 75 10 length in millimeters at full size 100 SUBMISSION GENERAL DEVELOPMENT NOTES ALL WORKS WITHIN ARE TO BE CARRIED OUT IN ACCORDANCE WITH THE BUILDING CODE OF AUSTRALIA & RELEVANT AUSTRALIAN STANDARDS. ALL WORKS DETAILED WITHIN THESE PLANS ARE TO BE CARRIED OUT BY A RELEVANT LICENSED TRADESPERSON. ALL PRODUCTS & FIXTURES TO INSTALLED IN ACCORDANCE WITH MANUFACTURERS DETAILS & RELEVANT AUSTRALIAN STANDARDS. PLANS ARE TO BE READ IN CONJUNCTION WITH PLANS AND DOCUMENTATION PROVIDED BY RELEVANT CONSULTANTS SUCH AS ENGINEERS, ENERGY ASSESSORS ETC. BOUNDARY LOCATIONS ARE TO BE CONFIRMED BY A REGISTERED SURVEYOR. PROPOSED WORKS ARE TO BE SETOUT ON SITE BY A REGISTERED SURVEYOR. LEVELS ON PLANS ARE INDICATIVE ONLY & ARE TO BE CONFIRMED BY A REGISTERED SURVEYOR PRIOR TO CONSTRUCTION. ALL UNDERGROUND SERVICES AND LOCATIONS ARE TO BE CONFIRMED PRIOR TO ANY WORK BEING UNDERTAKEN. ALL SERVICE CONNECTION APPROVALS AND REQUIREMENTS ARE TO BE OBTAINED AND CONFIRMED PRIOR TO ANY WORKS BEING UNDERTAKEN. WORKS ARE NOT TO BE UNDERTAKEN UNLESS PLANS ARE MARKED "CONSTRUCTION". DO NOT SCALE DRAWINGS - USE FIGURED DIMENSIONS ONLY. ANY ERRORS & OMISSIONS TO BE VERIFIED WITH THE DESIGNER PRIOR TO COMMENCEMENT ON SITE. WD00 - DRAWING SCHEDULE AND PERSPECTIVES WD01 - CODES & STANDARDS WD10 - SITE SETOUT PLAN WD20 - EXISTING/ DEMOLITION PLAN WD21 - PROPOSED FLOOR PLAN WD22 - UPPER GLAZING/ ROOF PLAN WD30 - ELEVATIONS WD31 - ELEVATIONS WD32 - SECTIONS WD40 - WET AREA DETAILS WD50 - DOOR CIRCULATIONS WD51 - CONSTRUCTION DETAILS DRAWING SCHEDULE ARTIST IMPRESSION NOT TO SCALE @A3 ARTIST IMPRESSION NOT TO SCALE @A3 ARTIST IMPRESSION NOT TO SCALE @A3 00 30/03/20 ISSUED FOR INTERNAL REVIEW AG 01 06/04/20 ISSUED FOR CLIENT REVIEW & SIGNOFF DP 02 27/08/20 ISSUED FOR CLIENT REVIEW & SIGNOFF SB 03 24/09/20 ISSUED FOR COUNCIL SUBMISSION SB

Upload: others

Post on 12-May-2022

4 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: NOT TO SCALE @A3 ARTIST IMPRESSION SUBM ION A RT ISMP …

CLIENT SIGNATURE DATE 19060Sheet No.:

Scale:Status:

Plot Date:

Project No:

Drawing Title:

Project Name

Client

COMMUNITY FACILITY

REV DATE AMENDMENT

24/9/20

/Volumes/Data/03 ARCHIVED PROJECTS/2019/19060 WALCHA MENS SHED/19060_sk2.pln

@ A3SUBMISSION

WD1

DRAWING SCHEDULE

172W FITZROY STREETWALCHANSW 2354

WALCHA MEN'S SHEDDT

5 15 20 25 50 7510 length in millimeters at full size 100

515

2025

5075

10le

ngth

in m

illim

eter

s at

full

size

100

S UBM IS S IONGENERAL DEVELOPMENT NOTESALL WORKS WITHIN ARE TO BE CARRIED OUT IN ACCORDANCE WITH THEBUILDING CODE OF AUSTRALIA & RELEVANT AUSTRALIAN STANDARDS.ALL WORKS DETAILED WITHIN THESE PLANS ARE TO BECARRIED OUT BY A RELEVANT LICENSED TRADESPERSON.ALL PRODUCTS & FIXTURES TO INSTALLED IN ACCORDANCE WITHMANUFACTURERS DETAILS & RELEVANT AUSTRALIAN STANDARDS.PLANS ARE TO BE READ IN CONJUNCTION WITH PLANS ANDDOCUMENTATION PROVIDED BY RELEVANT CONSULTANTSSUCH AS ENGINEERS, ENERGY ASSESSORS ETC.BOUNDARY LOCATIONS ARE TO BE CONFIRMED BYA REGISTERED SURVEYOR.

PROPOSED WORKS ARE TO BE SETOUT ON SITE BYA REGISTERED SURVEYOR.LEVELS ON PLANS ARE INDICATIVE ONLY & ARE TO BE CONFIRMED BYA REGISTERED SURVEYOR PRIOR TO CONSTRUCTION.ALL UNDERGROUND SERVICES AND LOCATIONS ARE TO BE CONFIRMEDPRIOR TO ANY WORK BEING UNDERTAKEN.ALL SERVICE CONNECTION APPROVALS AND REQUIREMENTS ARE TOBE OBTAINED AND CONFIRMED PRIOR TO ANY WORKS BEING UNDERTAKEN.WORKS ARE NOT TO BE UNDERTAKEN UNLESSPLANS ARE MARKED "CONSTRUCTION".DO NOT SCALE DRAWINGS - USE FIGURED DIMENSIONS ONLY.ANY ERRORS & OMISSIONS TO BE VERIFIED WITH THEDESIGNER PRIOR TO COMMENCEMENT ON SITE.

W D 0 0 - D R A W I N G S C H E D U L E

A N D P E R S P E C T I V E S

W D 0 1 - C O D E S & S T A N D A R D S

W D 1 0 - S I T E S E T O U T P L A N

W D 2 0 - E X I S T I N G / D E M O L I T I O N P L A N

W D 2 1 - P R O P O S E D F L O O R P L A N

W D 2 2 - U P P E R G L A Z I N G / R O O F P L A N

W D 3 0 - E L E V A T I O N S

W D 3 1 - E L E V A T I O N S

W D 3 2 - S E C T I O N S

W D 4 0 - W E T A R E A D E T A I L S

W D 5 0 - D O O R C I R C U L A T I O N S

W D 5 1 - C O N S T R U C T I O N D E T A I L S

DRAWING SCHEDULE

ARTIST IMPRESSIONNOT TO SCALE @A3

ARTIST IMPRESSIONNOT TO SCALE @A3

ARTIST IMPRESSIONNOT TO SCALE @A3

00 30/03/20 ISSUED FOR INTERNAL REVIEW AG01 06/04/20 ISSUED FOR CLIENT REVIEW & SIGNOFF DP02 27/08/20 ISSUED FOR CLIENT REVIEW & SIGNOFF SB03 24/09/20 ISSUED FOR COUNCIL SUBMISSION SB

Page 2: NOT TO SCALE @A3 ARTIST IMPRESSION SUBM ION A RT ISMP …

CLIENT SIGNATURE DATE 19060Sheet No.:

Scale:Status:

Plot Date:

Project No:

Drawing Title:

Project Name

Client

COMMUNITY FACILITY

REV DATE AMENDMENT

24/9/20

/Volumes/Data/03 ARCHIVED PROJECTS/2019/19060 WALCHA MENS SHED/19060_sk2.pln

@ A3SUBMISSION

WD2

CODES & STANDARDS

172W FITZROY STREETWALCHANSW 2354

WALCHA MEN'S SHEDDT

5 15 20 25 50 7510 length in millimeters at full size 100

515

2025

5075

10le

ngth

in m

illim

eter

s at

full

size

100

S UBM IS S ION

Report from 19060_GLAZING.xlsx printed 24/9/20

page 1 of 2

NCC VOLUME ONE GLAZING CALCULATOR (first issued with NCC 2014) Building name/description Application Climate zone

6

Storey Facade areas

N NE E SE S SW W NW internal

Option A 60m² 122m² 60m² 75m²Option B n/a

Glazing area (A) 6.6m² …………… 34.7m² …………… 4.38m² …………… 8.1m²

Number of rows preferred in table below 19 (as currently displayed)

GLAZING ELEMENTS, ORIENTATION SECTOR, SIZE and PERFORMANCE CHARACTERISTICS

Glazing element Size Performance Size Outcomes

IDOption A facades

Option Bfacades

Height(m)

Width(m)

Area(m²)

Total SystemU-Value(AFRC)

Total SystemSHGC

(AFRC)P

(m)H

(m) P/H G

(m)Heating

(SH)Cooling

(SC)Area used

(m²)

Element shareof % of

allowance used1 9

1 S 1.00 2.40 6.1 0.60 0.00 1.00 1.00 2.40 55% of 40%1 9

2 S 0.60 0.90 6.1 0.60 0.00 1.00 1.00 0.54 12% of 40%1 9

3 S 0.60 0.90 6.1 0.60 0.00 1.00 1.00 0.54 12% of 40%1 9

4 S 0.50 1.80 6.1 0.60 0.00 1.00 1.00 0.90 21% of 40%1 9

5 W 0.50 1.80 6.1 0.60 0.750 1.450 0.52 0.95 0.94 0.90 0.90 12% of 53%1 9

6 W 1.00 2.40 6.1 0.60 0.750 1.450 0.52 0.45 0.86 0.79 2.40 29% of 53%1 9

7 W 1.00 2.40 6.1 0.60 0.750 1.450 0.52 0.45 0.86 0.79 2.40 29% of 53%1 9

8 W 1.00 2.40 6.1 0.60 0.750 1.450 0.52 0.45 0.86 0.79 2.40 29% of 53%1 9

9 N 1.00 1.50 6.1 0.60 0.00 1.00 1.00 1.50 23% of 61%1 9

10 W10 N 1.00 1.80 6.1 0.60 0.00 1.00 1.00 1.80 27% of 61%1 9

11 W11 N 1.00 1.80 6.1 0.60 0.00 1.00 1.00 1.80 27% of 61%1 9

12 W12 N 1.00 1.50 6.1 0.60 0.00 1.00 1.00 1.50 23% of 61%1 9

13 W13 E 1.00 1.80 6.0 0.42 0.750 1.350 0.56 0.35 0.85 0.77 1.80 5% of 100%1 9

14 W14 E 1.00 3.00 6.0 0.42 0.750 1.350 0.56 0.35 0.85 0.77 3.00 9% of 100%1 9

15 W15 E 1.80 3.00 6.0 0.42 0.750 1.350 0.56 -0.45 0.67 0.63 5.40 15% of 100%1 9

16 W16 E 1.80 3.00 6.0 0.42 0.750 1.350 0.56 -0.45 0.67 0.63 5.40 15% of 100%1 9

17 SD01 E 2.10 2.40 6.0 0.42 0.750 2.400 0.31 0.30 0.94 0.90 5.04 17% of 100%1 9

18 SD02 E 2.10 2.40 6.0 0.42 0.750 2.400 0.31 0.30 0.94 0.90 5.04 17% of 100%1 9

19 UW01 E 0.50 18.00 6.0 0.42 0.750 0.650 1.15 0.15 0.54 0.52 9.00 22% of 100%

W08

W05W06W07

W09

W01W02W03W04

Description (optional)

Facing sector

other

1

CALCULATED OUTCOMES OK (if inputs are valid)

MultipliersShadingP&H or device

SHADING

WALCHA MENS SHED

ALL BUILDING WORK SHALL BE CARRIED OUT IN ACCORDANCE WITH THENATIONAL CONSTRUCTION CODE AND ALL RELEVANT AUSTRALIAN STANDARDS.

NCC SECTION A A6 - BUILDING CLASSIFICATION - CLASS 8 (A PROCESS-TYPE BUILDING FOR PRODUCTION, ASSEMBLING, ALTERING OR THELIKE OF PRODUCE FOR SALE TAKES A PLACE)

SECTION B ENSURE ALL BUILDING WORK IS CARRIED OUT IN ACCORDANCE WITH SECTION BOF THE NATIONAL CONSTRUCTION CODE

SECTION C C1.1 - 1 STOREY, CLASS 8 BUILDING. REQUIRES TYPE C CONSTRUCTION C1.8 - LIGHTWEIGHT CONSTRUCTION MUST COMPLY WITH SPECIFICATION C1.8 IF IT IS USED IN A WALLSYSTEM THAT IS REQUIRED TO HAVE A FRL C1.9 - MATERIALS THAT MAY BE USED WHEREVER A NON-COMBUSTABLE MATERIAL IS REQUIREDINCLUDE: PLASTERBOARD, PERFORATED GYPSUM LATH WITH A NORMAL PAPER FINISH, FIBROUS-PLASTERSHEET, FIBRE-REINFORCED CEMENT SHEETING, PRE-FINISHED METAL SHEETING HAVING A COMBUSTABLESURFACE FINISH NOT EXCEEDING 1mm THICKNESS AND WHERE THE SPREAD-OF-FLAME INDEX OF THE PRODUCTIN NOT GREATER THAN 0, SARKING-TYPE MATERIALS THAT DO NOT EXCEED 1mm IN THICKNESS AND HAVE AFLAMMABILITY INDEX NOT GREATER THAN 5, BONDED LAMINATED MATERIALS. C1.10 - THE FIRE HAZARD PROPERTIED FO THE FOLLOWING INTERNAL LININGS, MATERIALS AND ASSEMBLIESWITHIN A CLASS 2-9 BUILDING MUST COMPLY WITH SPECIFICATION C1.10: FLOOR LININGS AND COVERINGS, WALL/CEILING LININGS AND COVERINGS, AIR-HANDLING DUCTWORK, LIFT CARS,FIXED SEATING IN AUDIENCE AREAS,ESCALATORS/ MOVING WALKWAYS OR THE LIKE, SARKING-TYPE MATERIALS, ATTACHMENTS OR OTHER MATERIALSINCLUDING INSULATION MATERIALS OTHER THAN SARKING-TYPE MATERIALS. C2.2 - CLASS 8 BUILDING, 412.5 FLOOR AREA. REQUIRES TYPE C CONSTRUCTION

SECTION D D1.2 - EVERY BUILDING MUST HAVE AT LEAST ONE EXIT FROM EACH STOREY. IN ADDITION TO ANYHORIZONTAL EXIT NOT LESS THEN 2 EXITS MUST BE PROVIDED FROM EACH STOREY IF THE BUILDING HASAN EFFECTIVE HEIGHT OF MORE THAN 25m OR WHERE A BASEMENT HAS A VERTICAL RISE OF MORETHAN 1.5m UNLESS IT HAS A FLOOR ARE LESS THAN 50m2. D1.4 - CLASS 5/6/7/8/9 NO POINT ON A FLOOR MUST BE MORE THAN 20m FROM ANEXIT OR A POINT IN WHICH TRAVEL TO ALTERNATE EXITS IN DIFFERENT DIRECTIONS IS AVAILABLE IN WHICHCASE THE MAXIMUM DISTANCE TO ONE OF THE EXITS IS 40m. D1.5 - EXITS THAT ARE ALTERNATIVE MEANS OF EGRESS MUST BE NOT LESS THAN 9m APART.IN CLASS 2/3 BUILDINGS ARE NOT MORE THAN 45m APART. D1.6 - PATH OF TRAVEL TO AN EXIT MUST BE 2m IN HEIGHT EXCEPT THE HEIGHT OF ANY DOORWAYMAY BE REDUCED TO NOT LESS THAN 1980mm. THE UNOBSTRUCTED WITH OF EACH EXIT EXCEPTAT DOORWAYS MUST BE NOT LESS THAN 1m. D1.10 - AN EXIT MUST NOT BE BLOCKED AT THE POINT OF DISCHARGE, WHERE NECESSARYSUITABLE BARRIERS MUST BE PROVIDED TO PREVENT VEHICLES FROM BLOCKING THE EXIT. D2.15 - DOORWAY THRESHOLDS MUST NOT INCORPORATE A STEP OR RAMP AT ANY POINT CLOSERTO THE DOORWAY THAN THE WIDTH OF THE DOOR LEAF UNLESS IT IS PROVIDED WITH THRESHOLD RAMPOR STEP RAMP IN ACCORDANCE WITH AS1428.1. D2.20 - A SWINGING DOOR IN OR FORMING PART OF A REQUIRED EXIT MUST NOT ENCROACH ANYPART OF ITS SWING BY MORE THAN 500mm ON THE WIDTH OF ANY LANDINGS IN A STAIR, RAMOR OR PASSAGEWAY.THE DOOR MUST SWING IN THE DIRECTION OF EGRESS UNLESS IT SERVES A BUILDINGS WITH A FLOOR AREA NOTMORE THAN 200m2 AND IT IS THE ONLY REQUIRED EXIT FROM THE BUILDING AND IT IS FITTED WITH A HOLD OPEN DEVICE. D2.21 - A DOOR FORMING PART OF A REQUIRED EXIT IN A PATH OF TRAVEL MUST BE READILY OPENABLEWITHOUT A KEY FROM THE SIDE OF A PERSON SEEKING EGRESS BY A SINGLE HAND DOWN ACTION ON A DEVICELOCATED BETWEEN 900mm TO 1100mm FROM THE FLOOR OR, A SINGLE HAND PUSHING ACTION ON A DEVICELOCATED BETWEEN 900mm AND 1200mm FROM FLOOR LEVEL. D2.23 - A SIGN TO ALERT PERSONS THAT THE OPERATION OF CERTAIN DOORS MUST NOT BE IMPAIREDMUST BE INSTALLED WHERE IT CAN BE READILY SEEN ON OR ADJACENT TO A REQUIRED FIRE DOOR OR SMOKE DOOR. D3.1 - BUILDINGS AND PARTS OF THE BUILDING MUST BE ACCESSIBLE AS REQUIRED BY TABLE D3.1. D3.2 - AN ACCESS WAY MUST BE PROVIDED TO A BUILDING REQUIRED TO BE ACCESSIBLE FROM THE MAINPOINTS OF A PEDESTRIAN ENTRY AT THE ALLOTMENT BOUNDARY AND FROM ANOTHER ACCESSIBLE BUILDINGCONNECTED BY A PEDESTRIAN LINK AND FROM ANY ACCESSIBLE CAR PARKING SPACE. D3.3 - IN A BUILDING REQUIRED TO BE ACCESSIBLE MUST COMPLY WITH SECTION D3.3 OF THE BUILDING CODE. D3.4 - AREAS THAT ARE NOT REQUIRED TO BE ACCESSIBLE CAN INCLUDE AN AREA WHERE ACCESS WOULD BEINAPPROPRIATE BECAUSE OF THE PARTICULAR PURPOSE FOR WHICH THE AREA IS USED OR THAT WOULD POSEA HEALTH OR SAFETY RISK FOR PEOPLE WITH A DISABILITY OR ANY PATH OF TRAVEL PROVIDING ACCESS TO THESE AREAS. D3.5 - ACCESSIBLE CAR PARKING SPACES ARE TO BE PROVIDED IN ACCORDANCEWITH TABLE D3.5 OF THE BUILDING CODE. D3.6 - BRAILLE AND TACTILE SIGNAGE COMPLYING WITH SPECIFICATION D3.6, SIGNAGE INCLUDING THEINTERNATIONAL SYMBOL FOR DEAFNESS IN ACCORDANCE WITH AS1428.1, SIGNAGE IN ACCORDANCE WITHAS1428.1 FOR UNISEX SANITARY FACILITIES AND AMBULANT ACCESSIBLE SANITARY FACILITIES, PEDESTRIANENTRANCEWAY OR DIRECTIONAL SIGNAGE TO PEDESTRIAN ENTRANCE OR SANITARY FACILITIES MUST BEPROVIDED IN ANY BUILDING REQUIRED TO BE ACCESSIBLE.

SECTION E E1.3 - A FIRE HYDRANT SYSTEM MUST BE PROVIDED TO SERVE A BUILDING WITH A FLOOR AREAGREAER THAN 500m2 AND MUST BE INSTALLED IN ACCORDANCE WITH AS2419.1 E1.4 - FIRE HOSE REEL SYSTEM MUST BE PROVIDED TO SERVE THE WHOLE BUILDING WHERE ONEOR MORE INTERNAL FIRE HYDRANTS ARE INSTALLED OR WHERE HYDRANTS ARE NOT INSTALLED TO SERVEANY COMPARTMENT WITH A FLOOR AREA GREATER THAN 500m2. FIRE HOSE REELS MUST BE INSTALLEDIN ACCORDANCE WITH AS2441. E1.6 - PORTABLE FIRE EXTINGUISHERS MUST BE INSTALLED IN ACCORDANCE WITH TABLE E1.6 ANDLOCATED IN ACCORDANCE WITH SECTIONS 1,2,3 AND 4 OF AS2444. E3.1 - A LIFT MUST BE INSTALLED IN ACCORDANCE WITH SECTION E3 OF THE BUILDING CODE ANDMUST COMPLY WITH SPECIFICATION E3.1. E3.6 - IN AN ACCESSIBLE BUILDING EVERY PASSENGER LIFT UST BE ONE OF THE TYPES LISTEDIN TABLE E3.6A AND HAVE FEATURES OF TABLE E3.6B E4.2 - AN EMERGENCY LIGHTING SYSTEM MUST BE INSTALLED IN EVERY FIRE-ISOLATED STAIR,PASSAGE WAY OR RAMP AND IN EVERY STOREY OF A CLASS 5/6/7/8/9 BUILDING WHERE THE STOREYHAS A FLOOR AREA MORE THAN 300m2 IN EVERY PASSAGEWAY, CORRIDOR, HALLWAY OR THE LIKEFORMING PART OF THE PATH OF TRAVEL TO AN EXIT AND IN ANY ROOM HAVING A FLOOR ARE MORETHAN 100m2 THAT DOES NOT OPEN TO A CORRIDOR OR SPACE THAT HAS EMERGENCY LIGHTINGOR TO A ROAD OR OPEN SPACE AND IN ANY ROOM WITH A FLOOR ARE GREATER THAN 300m2. E4.4 - EVERY EMERGENCY LIGHTING SYSTEM MUST COMPLY WITH AS 2293.1 E4.5 - EXIT SIGNS MUST BE CLEARLY VISIBLE TO PERSONS APPROACHING THE EXIT AND MUSTBE INSTALLED ABOVE OR ADJACENT TO EACH EGRESS DOOR SERVING AS A REQUIRED EXIT. E4.6 - IF AN EXIT IS NOT READILY APPARENT TO PERSONS OCCUPYING THE BUILDING THEN EXITSIGNS MUST BE INSTALLED IN APPROPRIATE POSITIONS IN CORRIDORS, HALLWAYS OR THE LIKE INDICATINGDIRECTION TO A REQUIRED EXIT. E4.8 - ALL EXIT SIGNS MUST COMPLY WITH AS 2293.1 AND SPECIFICATION E4.8

SECTION F F1.1 - STORMWATER DRAINAGE MUST COMPLY WITH AS3500.3 F1.4 - WATERPROOFING MEMBRANES FOR EXTERNAL ABOVE GROUND USE MUST COMPLYWITH AS4645.1 AND AS4654.2 F1.5 - A ROOF MUST BE COVERED WITH ROOF TILES COMPLYING WITH AS2049 AND AS2050AS APPROPRIATE, CELLULOSE CEMENT CORRUGATED SHEETING COMPLYING WITH AS2908.1 AND INSTALLEDIN ACCORDANCE WITH AS 1562.2 OR METAL SHEET ROOFING COMPLYING WITH AS562.1 OR PLASTIC ROOFSHEETING IN ACCORDANCE WITH AS4256.1, AS4256.2, 4AS256.3, 4AS256.5 AND AS1562.3 F1.6 - SARKING-TYPE MATERIAL USED FOR WEATHERPROOFING OF ROOFS AND WALLS MUSTCOMPLY WITH AS4200.1 AND AS4200.2 F1.7 - IN A CLASS 5/6/7/8/9 BUILDING, ELEMENTS IN THE BATHROOM OR SHOWER ROOM, SLOPHOPPER, A LAUNDRY OR SANITARY COMPARTMENT MUST BE WATER RESISTANT OR WATERPROOFIN ACCORDANCE WITH TABLE F1.7 AND COMPLY WITH AS 3740 F2.4 - IN A BUILDING REQUIRED TO BE ACCESSIBLE AN ACCESSIBLE UNISEX SANITARY COMPARTMENT MUSTBE PROVIDED IN ACCORDANCE WITH TABLE F2.4 AND AT EACH BANK OF TOILETS WHERE THERE IS ONE OR MORE TOILETSIN ADDITION TO AN ACCESSIBLE UNISEX SANITARY COMPARTMENT, A SANITARY COMPARTMENT SUITABLE FOR A PERSON WITHAN AMBULANT DISABILITY IS TO BE INSTALLED IN ACCORDANCE WITH AS1428.1. ALL CIRCULATION SPACES, FIXTURES, FITTINGSMUST BE PROVIDED IN ACCORDANCE WITH TABLE F2.4A AND F2.4B AND MUST COMPLY WITH AS1428.1 AND MUST BE LOCATEDSO THAT IT CAN BE ENTERED WITHOUT CROSSING AN AREA RESERVED FOR ONE SEX ONLY.

F2.4 - THE DOOR TO A FULLY ENCLOSED SANITARY COMPARTMENT MUST OPEN OUTWARD, SLIDE OR BE READILYREMOVABLE FROM THE OUTSIDE. F4.8 - SANITARY COMPARTMENTS MUST NOT OPEN DIRECTLY INTO A KITCHEN, PANTRY, A PUBLIC DINING ROOF ORRESTAURANT, A ROOM USED FOR PUBLIC ASSEMBLY OR A WORKPLACE NORMALLY OCCUPIED BY MORE THAN ONE PERSON. F4.9 - IF A SANITARY COMPARTMENT IS PROHIBITED UNDER F4.8 FROM OPENING DIRECTLY TO ANOTHER ROOM INA CLASS 5/6/7/8/9 BUILDING, ACCESS BY AN AIRLOCK, HALL OR THE LIKE WITH A FLOOR AREA OF NOT LESS THAN 1.1m2 ANDFITTED WITH SELF-CLOSING DOORS. THE SANITARY COMPARTMENT MUST BE PROVIDED WITH MECHANICAL EXHAUSTVENTILATION AND THE DOORWAY TO THE ROOM ADEQUATELY SCREEN FROM VIEW. F4.11 - EVERY STOREY OF A CAR PARK MUST HAVE A MECHANICAL VENTILATION SYSTEM COMPLYING WITH AS1668.2OR A SYSTEM OF NATURAL VENTILATION COMPLYING WITH SECTION 4 OF AS1668.4 F4.12 - A COMMERCIAL KITCHEN MUST BE PROVIDED WITH A KITCHEN EXHAUST HOODCOMPLYING WITH AS1668.1 AND AS1668.2. F6.2 - WHERE A PLIABLE BUILDING MEMBRANE IS INSTALLED IN AN EXTERNAL WALL IT MUST COMPLY WIT AS4200.1AND BE INSTALLED IN ACCORDANCE WITH AS4200.2 .

SECTION J J1.2 - ENSURE ALL REQUIRED INSULATION IS INSTALLED IN ACCORDANCE WITH AS/NZS 4859.1 AND BE INSTALLEDIN ACCORDANCE WITH THE SECTION J REPORT

CONSTRUCTION NOTATION - ENSURE DOWNPIPES ARE INSTALLED TO CAPTURE ALL ROOF WATER RUN-OFF. ENSURE DOWNPIPES AREINSTALLED IN ACCORDANCE WITH THE NATIONAL CONSTRUCTION CODE AND AS2180. ENSURE ALL WORK IS CARRIEDOUT IN ACCORDANCE WITH ENGINEERS DETAILS. - PROVIDE TERMITE AND VERMIN PROTECTION IN ACCORDANCE WITH AS3660.1 AND MANUFACTURES DETAILS. - TIE DOWN AND BRACING SHOULD BE INSTALLED IN ACCORDANCE WITH ENGINEERS AND MANUFACTURES DETAILS.ENSURE ALL WORK IS CARRIED OUT IN ACCORDANCE WITH AS1684.2 - CONSTRUCTION JOINTS ARE TO BE PROTECTED IN ACCORDANCE WITH AS1530.4 - ALL SITE PARKING, ARROWS AND LINE MARKINGS ARE TO BE CARRIED OUT IN ACCORDANCE WITH THENATIONAL CONSTRUCTION CODE AND RELEVANT AUSTRALIAN STANDARDS. ACCESSIBLE CAR SPACES MUST BECARRIED OUT IN ACCORDANCE WITH AS29890.6. LOADING/ UNLOADING ZONES ARE TO BE CLEARLY MARKEDIN ACCORDANCE WITH CURRENT COUNCIL DEVELOPMENT CONTROL PLAN. - ANY OUTDOOR LIGHTING PROPOSED MUST BE COMPLETED IN ACCORDANCE WITH AS1158.3.1 AND AS4282 - ALL SANITARY COMPARTMENTS MUST HAVE A DOOR INSTALLED WITH LIFT OFF HINGES IN ACCORDANCEWITH THE BUILDING CODE. ACCESSIBLE TOILET SEATS MUST HAVE A LUMINANCE CONTRAST OF 30% TO THEBACKGROUND IN ACCORDANCE WITH AS1428.1. ALL ACCESSIBLE SANITARY COMPARTMENTS MUST BE INSTALLEDWITH A THERMOSTATIC MIXING VALVE IN ACCORDANCE WITH AS1428.1 - ENSURE ANY STAFF ROOM ACCESS DOOR IS OPERABLE WITH A FORCE LESS THAN 20N IN ACCORDANCEWITH CLAUSE 13.5 OF AS1428.1 - ALL RAMPS/ STAIRS ARE TO BE INSTALLED IN ACCORDANCE WITH AS1428.1 AND MUST HAVE A SLIPRESISTANT SURFACE IN ACCORDANCE WITH TABLE D21.4 OF THE BUILDING CODE. PROVIDE TACTILE INDICATORSWHERE REQUIRED. TACTILE INDICATORS MUST BE INSTALLED IN ACCORDANCE WTIH AS1428.4

GENERAL DEVELOPMENT NOTESALL WORKS WITHIN ARE TO BE CARRIED OUT IN ACCORDANCE WITH THEBUILDING CODE OF AUSTRALIA & RELEVANT AUSTRALIAN STANDARDS.ALL WORKS DETAILED WITHIN THESE PLANS ARE TO BECARRIED OUT BY A RELEVANT LICENSED TRADESPERSON.ALL PRODUCTS & FIXTURES TO INSTALLED IN ACCORDANCE WITHMANUFACTURERS DETAILS & RELEVANT AUSTRALIAN STANDARDS.PLANS ARE TO BE READ IN CONJUNCTION WITH PLANS ANDDOCUMENTATION PROVIDED BY RELEVANT CONSULTANTSSUCH AS ENGINEERS, ENERGY ASSESSORS ETC.BOUNDARY LOCATIONS ARE TO BE CONFIRMED BYA REGISTERED SURVEYOR.

PROPOSED WORKS ARE TO BE SETOUT ON SITE BYA REGISTERED SURVEYOR.LEVELS ON PLANS ARE INDICATIVE ONLY & ARE TO BE CONFIRMED BYA REGISTERED SURVEYOR PRIOR TO CONSTRUCTION.ALL UNDERGROUND SERVICES AND LOCATIONS ARE TO BE CONFIRMEDPRIOR TO ANY WORK BEING UNDERTAKEN.ALL SERVICE CONNECTION APPROVALS AND REQUIREMENTS ARE TOBE OBTAINED AND CONFIRMED PRIOR TO ANY WORKS BEING UNDERTAKEN.WORKS ARE NOT TO BE UNDERTAKEN UNLESSPLANS ARE MARKED "CONSTRUCTION".DO NOT SCALE DRAWINGS - USE FIGURED DIMENSIONS ONLY.ANY ERRORS & OMISSIONS TO BE VERIFIED WITH THEDESIGNER PRIOR TO COMMENCEMENT ON SITE.

00 30/03/20 ISSUED FOR INTERNAL REVIEW AG01 06/04/20 ISSUED FOR CLIENT REVIEW & SIGNOFF DP02 27/08/20 ISSUED FOR CLIENT REVIEW & SIGNOFF SB03 24/09/20 ISSUED FOR COUNCIL SUBMISSION SB

Page 3: NOT TO SCALE @A3 ARTIST IMPRESSION SUBM ION A RT ISMP …

CLIENT SIGNATURE DATE 19060Sheet No.:

Scale:Status:

Plot Date:

Project No:

Drawing Title:

Project Name

Client

COMMUNITY FACILITY

REV DATE AMENDMENT

24/9/20

/Volumes/Data/03 ARCHIVED PROJECTS/2019/19060 WALCHA MENS SHED/19060_sk2.pln

1:250 @ A3SUBMISSION

WD3

SITE SETOUT PLAN

172W FITZROY STREETWALCHANSW 2354

WALCHA MEN'S SHEDDT

5 15 20 25 50 7510 length in millimeters at full size 100

515

2025

5075

10le

ngth

in m

illim

eter

s at

full

size

100

S UBM IS S ION

3,00

0

21,000

21,0

00

40,850

EXIST.WT

LOT 4DP 24385

APPROX SITE AREA: 3,515m2

APPROX BOUNDARY 87 000

APPROX BOUNDARY 87 000

APPR

OX B

OUND

ARY

40 40

0

APPR

OX B

OUND

ARY

40 40

0

EXISTING BUILDINGSHOWN DASHED

TO BE DEMOLISHED

EXISTINGSITE ACCESS

FI

TZ

RO

Y S

TR

EE

T

EXIST. FLAG POLETO BE DEMOLISHED

PROPOSEDSHED

N

GENERAL DEVELOPMENT NOTESALL WORKS WITHIN ARE TO BE CARRIED OUT IN ACCORDANCE WITH THEBUILDING CODE OF AUSTRALIA & RELEVANT AUSTRALIAN STANDARDS.ALL WORKS DETAILED WITHIN THESE PLANS ARE TO BECARRIED OUT BY A RELEVANT LICENSED TRADESPERSON.ALL PRODUCTS & FIXTURES TO INSTALLED IN ACCORDANCE WITHMANUFACTURERS DETAILS & RELEVANT AUSTRALIAN STANDARDS.PLANS ARE TO BE READ IN CONJUNCTION WITH PLANS ANDDOCUMENTATION PROVIDED BY RELEVANT CONSULTANTSSUCH AS ENGINEERS, ENERGY ASSESSORS ETC.BOUNDARY LOCATIONS ARE TO BE CONFIRMED BYA REGISTERED SURVEYOR.

PROPOSED WORKS ARE TO BE SETOUT ON SITE BYA REGISTERED SURVEYOR.LEVELS ON PLANS ARE INDICATIVE ONLY & ARE TO BE CONFIRMED BYA REGISTERED SURVEYOR PRIOR TO CONSTRUCTION.ALL UNDERGROUND SERVICES AND LOCATIONS ARE TO BE CONFIRMEDPRIOR TO ANY WORK BEING UNDERTAKEN.ALL SERVICE CONNECTION APPROVALS AND REQUIREMENTS ARE TOBE OBTAINED AND CONFIRMED PRIOR TO ANY WORKS BEING UNDERTAKEN.WORKS ARE NOT TO BE UNDERTAKEN UNLESSPLANS ARE MARKED "CONSTRUCTION".DO NOT SCALE DRAWINGS - USE FIGURED DIMENSIONS ONLY.ANY ERRORS & OMISSIONS TO BE VERIFIED WITH THEDESIGNER PRIOR TO COMMENCEMENT ON SITE.

BUILDING CLASS - 8SITE AREASEXISTING BUILDING AREA 251.0m2

PROPOSED BUILDING AREA 412.5m2

ROOF AREA 455.1m2

LEGENDSWP STORMWATER PITBOL BOLLARDSC STEEL COLUMNDP DOWN PIPERC REINFORCED CONCRETEWM WATER METERCL CLOTHES LINEHWU HOT WATER UNITMSB MAIN SWITCH BOARDFFL FINISHED FLOOR LEVELFSL FINISHED SLAB LEVELEGL EXISTING GROUND LEVELFGL FINISHED GROUND LEVEL

SITE SETOUT PLANSCALE 1:250@A3

00 30/03/20 ISSUED FOR INTERNAL REVIEW AG01 06/04/20 ISSUED FOR CLIENT REVIEW & SIGNOFF DP02 27/08/20 ISSUED FOR CLIENT REVIEW & SIGNOFF SB03 24/09/20 ISSUED FOR COUNCIL SUBMISSION SB

Page 4: NOT TO SCALE @A3 ARTIST IMPRESSION SUBM ION A RT ISMP …

CLIENT SIGNATURE DATE 19060Sheet No.:

Scale:Status:

Plot Date:

Project No:

Drawing Title:

Project Name

Client

COMMUNITY FACILITY

REV DATE AMENDMENT

24/9/20

/Volumes/Data/03 ARCHIVED PROJECTS/2019/19060 WALCHA MENS SHED/19060_sk2.pln

1:100 @ A3SUBMISSION

WD4

EXISTING/DEMOLITION PLAN

172W FITZROY STREETWALCHANSW 2354

WALCHA MEN'S SHEDDT

5 15 20 25 50 7510 length in millimeters at full size 100

515

2025

5075

10le

ngth

in m

illim

eter

s at

full

size

100

S UBM IS S ION

EXISTINGHALL

EXISTINGOFFICE

EXISTINGLUNCH / KITCHEN

EXISTINGSTORAGE

EXISTINGSTORAGE

EXISTINGSTORAGEEXISTING

ENTRY

EXIST.WC

EXIST.WC

NOTE: ALL EXISTING WALLS, DOORS, WINDOWSFIXTURES AND STRUCTURE SHOWN DASHED ISTO BE DEMOLISHED. ENSURE ALL WORK IS CARRIEDOUT BY COMPETENT CONSULTANTS AND TRADESPEOPLE. ENSURE ALL WORKS ARE CARRIED OUTIN ACCORDANCE WITH RELEVANT BUILDINGCODES AND AUSTRALIAN STANDARDS.

N

GENERAL DEVELOPMENT NOTESALL WORKS WITHIN ARE TO BE CARRIED OUT IN ACCORDANCE WITH THEBUILDING CODE OF AUSTRALIA & RELEVANT AUSTRALIAN STANDARDS.ALL WORKS DETAILED WITHIN THESE PLANS ARE TO BECARRIED OUT BY A RELEVANT LICENSED TRADESPERSON.ALL PRODUCTS & FIXTURES TO INSTALLED IN ACCORDANCE WITHMANUFACTURERS DETAILS & RELEVANT AUSTRALIAN STANDARDS.PLANS ARE TO BE READ IN CONJUNCTION WITH PLANS ANDDOCUMENTATION PROVIDED BY RELEVANT CONSULTANTSSUCH AS ENGINEERS, ENERGY ASSESSORS ETC.BOUNDARY LOCATIONS ARE TO BE CONFIRMED BYA REGISTERED SURVEYOR.

PROPOSED WORKS ARE TO BE SETOUT ON SITE BYA REGISTERED SURVEYOR.LEVELS ON PLANS ARE INDICATIVE ONLY & ARE TO BE CONFIRMED BYA REGISTERED SURVEYOR PRIOR TO CONSTRUCTION.ALL UNDERGROUND SERVICES AND LOCATIONS ARE TO BE CONFIRMEDPRIOR TO ANY WORK BEING UNDERTAKEN.ALL SERVICE CONNECTION APPROVALS AND REQUIREMENTS ARE TOBE OBTAINED AND CONFIRMED PRIOR TO ANY WORKS BEING UNDERTAKEN.WORKS ARE NOT TO BE UNDERTAKEN UNLESSPLANS ARE MARKED "CONSTRUCTION".DO NOT SCALE DRAWINGS - USE FIGURED DIMENSIONS ONLY.ANY ERRORS & OMISSIONS TO BE VERIFIED WITH THEDESIGNER PRIOR TO COMMENCEMENT ON SITE.

LEGENDWT 3000LITRE WATER TANKTP 200x200 TIMBER POSTBP 350x350 BRICK PEIRSC 90x90 STEEL COLUMN SMOKE ALARM 350Hx500W NICHEDP DOWN PIPEST STOVESNK SINKWC WATER CLOSETSHR SHOWERRC REINFORCED CONCRETEWM WATER METERCL CLOTHES LINE

SA

FW FLOOR WASTEHWU HOT WATER UNITMSB MAIN SWITCH BOARDFFL FINISHED FLOOR LEVELFSL FINISHED SLAB LEVELEGL EXISTING GROUND LEVELFGL FINISHED GROUND LEVEL

FLOOR AREASEXISTING SHED AREA 237.4m²EXISTING CONCRETE AREA 13.6m²TOTAL EXISTING 251.0m²

EXISTING/ DEMOLITION PLANSCALE 1:100@A3

00 30/03/20 ISSUED FOR INTERNAL REVIEW AG01 06/04/20 ISSUED FOR CLIENT REVIEW & SIGNOFF DP02 27/08/20 ISSUED FOR CLIENT REVIEW & SIGNOFF SB03 24/09/20 ISSUED FOR COUNCIL SUBMISSION SB

Page 5: NOT TO SCALE @A3 ARTIST IMPRESSION SUBM ION A RT ISMP …

CLIENT SIGNATURE DATE 19060Sheet No.:

Scale:Status:

Plot Date:

Project No:

Drawing Title:

Project Name

Client

COMMUNITY FACILITY

REV DATE AMENDMENT

24/9/20

/Volumes/Data/03 ARCHIVED PROJECTS/2019/19060 WALCHA MENS SHED/19060_sk2.pln

1:100 @ A3SUBMISSION

WD5

PROPOSED FLOOR PLAN

172W FITZROY STREETWALCHANSW 2354

WALCHA MEN'S SHEDDT

5 15 20 25 50 7510 length in millimeters at full size 100

515

2025

5075

10le

ngth

in m

illim

eter

s at

full

size

100

S UBM IS S ION

10-24SW 10-24SW 10-24SW05-18SW920

05-1

8SW

06-0

9SW

06-0

9SW

920

18-30SW 18-30SW 10-30SW 10-18SW21-24SD02 21-24SD01

920

920

920

920

10-18SW10-18SW920 920920

820

820

10-1

8SW

10-1

5SW

10-1

8SW

24-2

7ROL

LER

DOOR

920

10-2

4SW

10-1

5SW

920

24-2

7ROL

LER

DOOR

DP DPDPDP

DP DPDPDP 906,

050

906,

990

903,

000

90

906,

050

902,

300

901,

400

901,

530

904,

580

90

90 3,500 90 17,790 90 3,500 90

90 1,880 90 1,530 90 21,380 90

90 3,500 90 15,790 90 5,500 90

90 3,500 90 21,380 90

6,14

010

,260

25,150

6,14

010

,260

25,150

16,4

00

A

A

B B

W06 W07 W08W05

W04

W03

W02

W16 W15 W14 W13

G02G01

W11

W09

W10

W01

W12

WOODWORK

METALWORK

NURSERY

LUNCH /RECREATIONKITOFFICE

ACC. WC

WC

TOOLSTORE

EXIT

EXIT

EXIT

EXIT EXIT

EXIT

EXIT

1 2

A

B

C

1 2

A

B

C

ACC.

SIG

NAC

C. S

IGN

ACC.

SIG

N

ACC. SIGNACC. SIGN

ACC. SIGNACC. SIGNAC

C. S

IGN

ACC.

SIG

N

BUILDER TO PROVIDE ACCESSIBLE SIGNAGEPANELS IN ACCORDANCE WITH AS 1428.1

PLUMBER TO PROVIDETHERMOSTATIC MIXING VALVETO ACC. WC IN ACCORDANCE

WITH AS 3500

BUILDER/ELECTRICIAN TO PROVIDEEMERGENCY LIGHTING IN ACCORDANCE WITH AS2293

DESIGN AND OPERATION OF EXIT SIGNS TO COMPLY WITHAS2293.1 OR SPECIFICATION E4.8

ACCESSIBLE TOILET SEATS MUST HAVEA LUMINANCE CONTRAST OF 30% TO THE

BACKGROUND IN ACCORDANCE WITH AS1428.1

ENTRY/EXIT DOORS TO BE CLEARLYMARKED IN ACCORDANCE WITH AS1428.1

awnin

g ove

raw

ning o

ver

FIRE EXTINGUISHERS MUST BE PROVIDED INACCORDANCE WITH TABLE E1.6 OFTHE BUILDING CODE OF AUSTRALIA

GENERAL DEVELOPMENT NOTESALL WORKS WITHIN ARE TO BE CARRIED OUT IN ACCORDANCE WITH THEBUILDING CODE OF AUSTRALIA & RELEVANT AUSTRALIAN STANDARDS.ALL WORKS DETAILED WITHIN THESE PLANS ARE TO BECARRIED OUT BY A RELEVANT LICENSED TRADESPERSON.ALL PRODUCTS & FIXTURES TO INSTALLED IN ACCORDANCE WITHMANUFACTURERS DETAILS & RELEVANT AUSTRALIAN STANDARDS.PLANS ARE TO BE READ IN CONJUNCTION WITH PLANS ANDDOCUMENTATION PROVIDED BY RELEVANT CONSULTANTSSUCH AS ENGINEERS, ENERGY ASSESSORS ETC.BOUNDARY LOCATIONS ARE TO BE CONFIRMED BYA REGISTERED SURVEYOR.

PROPOSED WORKS ARE TO BE SETOUT ON SITE BYA REGISTERED SURVEYOR.LEVELS ON PLANS ARE INDICATIVE ONLY & ARE TO BE CONFIRMED BYA REGISTERED SURVEYOR PRIOR TO CONSTRUCTION.ALL UNDERGROUND SERVICES AND LOCATIONS ARE TO BE CONFIRMEDPRIOR TO ANY WORK BEING UNDERTAKEN.ALL SERVICE CONNECTION APPROVALS AND REQUIREMENTS ARE TOBE OBTAINED AND CONFIRMED PRIOR TO ANY WORKS BEING UNDERTAKEN.WORKS ARE NOT TO BE UNDERTAKEN UNLESSPLANS ARE MARKED "CONSTRUCTION".DO NOT SCALE DRAWINGS - USE FIGURED DIMENSIONS ONLY.ANY ERRORS & OMISSIONS TO BE VERIFIED WITH THEDESIGNER PRIOR TO COMMENCEMENT ON SITE.

LEGENDWT 3000LITRE WATER TANKTP 200x200 TIMBER POSTBP 350x350 BRICK PEIRSC 90x90 STEEL COLUMN SMOKE ALARM 350Hx500W NICHEDP DOWN PIPEST STOVESNK SINKWC WATER CLOSETSHR SHOWERRC REINFORCED CONCRETEWM WATER METERCL CLOTHES LINE

SA

FW FLOOR WASTEHWU HOT WATER UNITMSB MAIN SWITCH BOARDFFL FINISHED FLOOR LEVELFSL FINISHED SLAB LEVELEGL EXISTING GROUND LEVELFGL FINISHED GROUND LEVEL

FLOOR AREASPROPOSED SHED AREA 412.5m²TOTAL 412.5m²

PROPOSED FLOOR PLANSCALE 1:100@A3

00 30/03/20 ISSUED FOR INTERNAL REVIEW AG01 06/04/20 ISSUED FOR CLIENT REVIEW & SIGNOFF DP02 27/08/20 ISSUED FOR CLIENT REVIEW & SIGNOFF SB03 24/09/20 ISSUED FOR COUNCIL SUBMISSION SB

Page 6: NOT TO SCALE @A3 ARTIST IMPRESSION SUBM ION A RT ISMP …

CLIENT SIGNATURE DATE 19060Sheet No.:

Scale:Status:

Plot Date:

Project No:

Drawing Title:

Project Name

Client

COMMUNITY FACILITY

REV DATE AMENDMENT

24/9/20

/Volumes/Data/03 ARCHIVED PROJECTS/2019/19060 WALCHA MENS SHED/19060_sk2.pln

1:100 @ A3SUBMISSION

WD6

UPPER GLAZING/ ROOF PLAN

172W FITZROY STREETWALCHANSW 2354

WALCHA MEN'S SHEDDT

5 15 20 25 50 7510 length in millimeters at full size 100

515

2025

5075

10le

ngth

in m

illim

eter

s at

full

size

100

S UBM IS S ION

05-180FG

600

600

750

UW01

1 2

A

B

C

1 2

A

B

CRO

OF FA

LL 10

ºRO

OF FA

LL 10

º

GENERAL DEVELOPMENT NOTESALL WORKS WITHIN ARE TO BE CARRIED OUT IN ACCORDANCE WITH THEBUILDING CODE OF AUSTRALIA & RELEVANT AUSTRALIAN STANDARDS.ALL WORKS DETAILED WITHIN THESE PLANS ARE TO BECARRIED OUT BY A RELEVANT LICENSED TRADESPERSON.ALL PRODUCTS & FIXTURES TO INSTALLED IN ACCORDANCE WITHMANUFACTURERS DETAILS & RELEVANT AUSTRALIAN STANDARDS.PLANS ARE TO BE READ IN CONJUNCTION WITH PLANS ANDDOCUMENTATION PROVIDED BY RELEVANT CONSULTANTSSUCH AS ENGINEERS, ENERGY ASSESSORS ETC.BOUNDARY LOCATIONS ARE TO BE CONFIRMED BYA REGISTERED SURVEYOR.

PROPOSED WORKS ARE TO BE SETOUT ON SITE BYA REGISTERED SURVEYOR.LEVELS ON PLANS ARE INDICATIVE ONLY & ARE TO BE CONFIRMED BYA REGISTERED SURVEYOR PRIOR TO CONSTRUCTION.ALL UNDERGROUND SERVICES AND LOCATIONS ARE TO BE CONFIRMEDPRIOR TO ANY WORK BEING UNDERTAKEN.ALL SERVICE CONNECTION APPROVALS AND REQUIREMENTS ARE TOBE OBTAINED AND CONFIRMED PRIOR TO ANY WORKS BEING UNDERTAKEN.WORKS ARE NOT TO BE UNDERTAKEN UNLESSPLANS ARE MARKED "CONSTRUCTION".DO NOT SCALE DRAWINGS - USE FIGURED DIMENSIONS ONLY.ANY ERRORS & OMISSIONS TO BE VERIFIED WITH THEDESIGNER PRIOR TO COMMENCEMENT ON SITE.

LEGENDWT 3000LITRE WATER TANKTP 200x200 TIMBER POSTBP 350x350 BRICK PEIRSC 90x90 STEEL COLUMN SMOKE ALARM 350Hx500W NICHEDP DOWN PIPEST STOVESNK SINKWC WATER CLOSETSHR SHOWERRC REINFORCED CONCRETEWM WATER METERCL CLOTHES LINE

SA

FW FLOOR WASTEHWU HOT WATER UNITMSB MAIN SWITCH BOARDFFL FINISHED FLOOR LEVELFSL FINISHED SLAB LEVELEGL EXISTING GROUND LEVELFGL FINISHED GROUND LEVEL

UPPER GLAZING/ROOF PLANSCALE 1:100@A3

00 30/03/20 ISSUED FOR INTERNAL REVIEW AG01 06/04/20 ISSUED FOR CLIENT REVIEW & SIGNOFF DP02 27/08/20 ISSUED FOR CLIENT REVIEW & SIGNOFF SB03 24/09/20 ISSUED FOR COUNCIL SUBMISSION SB

Page 7: NOT TO SCALE @A3 ARTIST IMPRESSION SUBM ION A RT ISMP …

CLIENT SIGNATURE DATE 19060Sheet No.:

Scale:Status:

Plot Date:

Project No:

Drawing Title:

Project Name

Client

COMMUNITY FACILITY

REV DATE AMENDMENT

24/9/20

/Volumes/Data/03 ARCHIVED PROJECTS/2019/19060 WALCHA MENS SHED/19060_sk2.pln

1:100 @ A3SUBMISSION

WD7

ELEVATIONS

172W FITZROY STREETWALCHANSW 2354

WALCHA MEN'S SHEDDT

5 15 20 25 50 7510 length in millimeters at full size 100

515

2025

5075

10le

ngth

in m

illim

eter

s at

full

size

100

S UBM IS S ION

FSL

5,17

5TO

P O

F R

IDG

E2,

550

2,25

0

ALUM

INIU

M FR

AMED

SLID

ING

GLAS

S DO

OR

ALUM

INIU

M FR

AMED

SLID

ING

GLAS

S W

INDO

W

ALUM

INIU

M FR

AMED

FIXE

D GL

ASS

WIN

DOW

COLO

RBON

D CU

STOM

ORB

ROOF

SHE

ETIN

G AS

SEL

ECTE

D

COLO

RBON

D GU

TTER

AND

FASC

IA A

S SE

LECT

ED

FINISHED GROUND LEVEL

FSL

3,00

0

2,55

0

ROOF PITCH 10°

ROOF PITCH 10°

ALUM

INIU

M FR

AMED

SLID

ING

GLAS

S W

INDO

W

COLO

RBON

D CU

STOM

ORB

ROOF

SHE

ETIN

G AS

SEL

ECTE

D

COLO

RBON

D GU

TTER

AND

FASC

IA A

S SE

LECT

ED

FINISHED GROUND LEVEL

COLO

RBON

D CU

STOM

ORB

ROOF

SHE

ETIN

G AS

SEL

ECTE

D

EASTERN ELEVATIONSCALE 1:100@A3 SHEET

SOUTHERN ELEVATION / FITZROY STREETSCALE 1:100@A3 SHEET

GENERAL DEVELOPMENT NOTESALL WORKS WITHIN ARE TO BE CARRIED OUT IN ACCORDANCE WITH THEBUILDING CODE OF AUSTRALIA & RELEVANT AUSTRALIAN STANDARDS.ALL WORKS DETAILED WITHIN THESE PLANS ARE TO BECARRIED OUT BY A RELEVANT LICENSED TRADESPERSON.ALL PRODUCTS & FIXTURES TO INSTALLED IN ACCORDANCE WITHMANUFACTURERS DETAILS & RELEVANT AUSTRALIAN STANDARDS.PLANS ARE TO BE READ IN CONJUNCTION WITH PLANS ANDDOCUMENTATION PROVIDED BY RELEVANT CONSULTANTSSUCH AS ENGINEERS, ENERGY ASSESSORS ETC.BOUNDARY LOCATIONS ARE TO BE CONFIRMED BYA REGISTERED SURVEYOR.

PROPOSED WORKS ARE TO BE SETOUT ON SITE BYA REGISTERED SURVEYOR.LEVELS ON PLANS ARE INDICATIVE ONLY & ARE TO BE CONFIRMED BYA REGISTERED SURVEYOR PRIOR TO CONSTRUCTION.ALL UNDERGROUND SERVICES AND LOCATIONS ARE TO BE CONFIRMEDPRIOR TO ANY WORK BEING UNDERTAKEN.ALL SERVICE CONNECTION APPROVALS AND REQUIREMENTS ARE TOBE OBTAINED AND CONFIRMED PRIOR TO ANY WORKS BEING UNDERTAKEN.WORKS ARE NOT TO BE UNDERTAKEN UNLESSPLANS ARE MARKED "CONSTRUCTION".DO NOT SCALE DRAWINGS - USE FIGURED DIMENSIONS ONLY.ANY ERRORS & OMISSIONS TO BE VERIFIED WITH THEDESIGNER PRIOR TO COMMENCEMENT ON SITE.

00 30/03/20 ISSUED FOR INTERNAL REVIEW AG01 06/04/20 ISSUED FOR CLIENT REVIEW & SIGNOFF DP02 27/08/20 ISSUED FOR CLIENT REVIEW & SIGNOFF SB03 24/09/20 ISSUED FOR COUNCIL SUBMISSION SB

Page 8: NOT TO SCALE @A3 ARTIST IMPRESSION SUBM ION A RT ISMP …

CLIENT SIGNATURE DATE 19060Sheet No.:

Scale:Status:

Plot Date:

Project No:

Drawing Title:

Project Name

Client

COMMUNITY FACILITY

REV DATE AMENDMENT

24/9/20

/Volumes/Data/03 ARCHIVED PROJECTS/2019/19060 WALCHA MENS SHED/19060_sk2.pln

1:100 @ A3SUBMISSION

WD8

ELEVATIONS

172W FITZROY STREETWALCHANSW 2354

WALCHA MEN'S SHEDDT

5 15 20 25 50 7510 length in millimeters at full size 100

515

2025

5075

10le

ngth

in m

illim

eter

s at

full

size

100

S UBM IS S ION

FSL

3,00

0

ALUM

INIU

M FR

AMED

SLID

ING

GLAS

S W

INDO

W

COLO

RBON

D CU

STOM

ORB

ROOF

SHE

ETIN

G AS

SEL

ECTE

D

COLO

RBON

D GU

TTER

AND

FASC

IA A

S SE

LECT

EDFINISHED GROUND LEVEL

FSL

2,55

0

3,00

0

ROOF PITCH 10°

ROOF PITCH 10°

ALUM

INIU

M FR

AMED

SLID

ING

GLAS

S W

INDO

W

COLO

RBON

D CU

STOM

ORB

ROOF

SHE

ETIN

G AS

SEL

ECTE

D

COLO

RBON

D GU

TTER

AND

FASC

IA A

S SE

LECT

ED

FINISHED GROUND LEVEL

COLO

RBON

D CU

STOM

ORB

ROOF

SHE

ETIN

G AS

SEL

ECTE

D

WESTERN ELEVATIONSCALE 1:100@A3 SHEET

NORTHERN ELEVATIONSCALE 1:100@A3 SHEET

GENERAL DEVELOPMENT NOTESALL WORKS WITHIN ARE TO BE CARRIED OUT IN ACCORDANCE WITH THEBUILDING CODE OF AUSTRALIA & RELEVANT AUSTRALIAN STANDARDS.ALL WORKS DETAILED WITHIN THESE PLANS ARE TO BECARRIED OUT BY A RELEVANT LICENSED TRADESPERSON.ALL PRODUCTS & FIXTURES TO INSTALLED IN ACCORDANCE WITHMANUFACTURERS DETAILS & RELEVANT AUSTRALIAN STANDARDS.PLANS ARE TO BE READ IN CONJUNCTION WITH PLANS ANDDOCUMENTATION PROVIDED BY RELEVANT CONSULTANTSSUCH AS ENGINEERS, ENERGY ASSESSORS ETC.BOUNDARY LOCATIONS ARE TO BE CONFIRMED BYA REGISTERED SURVEYOR.

PROPOSED WORKS ARE TO BE SETOUT ON SITE BYA REGISTERED SURVEYOR.LEVELS ON PLANS ARE INDICATIVE ONLY & ARE TO BE CONFIRMED BYA REGISTERED SURVEYOR PRIOR TO CONSTRUCTION.ALL UNDERGROUND SERVICES AND LOCATIONS ARE TO BE CONFIRMEDPRIOR TO ANY WORK BEING UNDERTAKEN.ALL SERVICE CONNECTION APPROVALS AND REQUIREMENTS ARE TOBE OBTAINED AND CONFIRMED PRIOR TO ANY WORKS BEING UNDERTAKEN.WORKS ARE NOT TO BE UNDERTAKEN UNLESSPLANS ARE MARKED "CONSTRUCTION".DO NOT SCALE DRAWINGS - USE FIGURED DIMENSIONS ONLY.ANY ERRORS & OMISSIONS TO BE VERIFIED WITH THEDESIGNER PRIOR TO COMMENCEMENT ON SITE.

00 30/03/20 ISSUED FOR INTERNAL REVIEW AG01 06/04/20 ISSUED FOR CLIENT REVIEW & SIGNOFF DP02 27/08/20 ISSUED FOR CLIENT REVIEW & SIGNOFF SB03 24/09/20 ISSUED FOR COUNCIL SUBMISSION SB

Page 9: NOT TO SCALE @A3 ARTIST IMPRESSION SUBM ION A RT ISMP …

CLIENT SIGNATURE DATE 19060Sheet No.:

Scale:Status:

Plot Date:

Project No:

Drawing Title:

Project Name

Client

COMMUNITY FACILITY

REV DATE AMENDMENT

24/9/20

/Volumes/Data/03 ARCHIVED PROJECTS/2019/19060 WALCHA MENS SHED/19060_sk2.pln

@ A3SUBMISSION

WD9

SECTIONS

172W FITZROY STREETWALCHANSW 2354

WALCHA MEN'S SHEDDT

5 15 20 25 50 7510 length in millimeters at full size 100

515

2025

5075

10le

ngth

in m

illim

eter

s at

full

size

100

S UBM IS S ION

FSL

2,55

0

3,00

0 WOODWORK KIT

COLO

RBON

D CU

STOM

ORB

ROOF

SHE

ETIN

G AS

SEL

ECTE

D

ROOF

TRU

SSES

TO

MANU

FACT

URER

S DE

TAILS

ROOF

STR

UCTU

RE T

OEN

GINE

ERS

DETA

ILS

COLO

RBON

D GU

TTER

AND

FASC

IA A

S SE

LECT

ED

WALL AND CEILING INSULATION AND LININGSTO MATCH SECTION J REPORT

RC SLAB TO ENG. DETAILS

HARD

IFLE

X SO

FFIT

LINI

NGTO

MAN

UFAC

TURE

RS D

ETAI

LS

WAL

L CLA

DDIN

G AS

SEL

ECTE

D

WALL AND CEILING INSULATION TO MATCH SECTION J REPORT

FSL

WOODWORKTOOLSTORE

COLO

RBON

D CU

STOM

ORB

ROOF

SHE

ETIN

G AS

SEL

ECTE

D

ROOF

TRU

SSES

TO

MANU

FACT

URER

S DE

TAILS

ROOF

STR

UCTU

RE T

OEN

GINE

ERS

DETA

ILS

WALL AND CEILING INSULATIONTO MATCH SECTION J REPORT

RC SLAB TO ENG. DETAILS

WAL

L CLA

DDIN

G AS

SEL

ECTE

D

WALL AND CEILING INSULATIONTO MATCH SECTION J REPORT

GENERAL DEVELOPMENT NOTESALL WORKS WITHIN ARE TO BE CARRIED OUT IN ACCORDANCE WITH THEBUILDING CODE OF AUSTRALIA & RELEVANT AUSTRALIAN STANDARDS.ALL WORKS DETAILED WITHIN THESE PLANS ARE TO BECARRIED OUT BY A RELEVANT LICENSED TRADESPERSON.ALL PRODUCTS & FIXTURES TO INSTALLED IN ACCORDANCE WITHMANUFACTURERS DETAILS & RELEVANT AUSTRALIAN STANDARDS.PLANS ARE TO BE READ IN CONJUNCTION WITH PLANS ANDDOCUMENTATION PROVIDED BY RELEVANT CONSULTANTSSUCH AS ENGINEERS, ENERGY ASSESSORS ETC.BOUNDARY LOCATIONS ARE TO BE CONFIRMED BYA REGISTERED SURVEYOR.

PROPOSED WORKS ARE TO BE SETOUT ON SITE BYA REGISTERED SURVEYOR.LEVELS ON PLANS ARE INDICATIVE ONLY & ARE TO BE CONFIRMED BYA REGISTERED SURVEYOR PRIOR TO CONSTRUCTION.ALL UNDERGROUND SERVICES AND LOCATIONS ARE TO BE CONFIRMEDPRIOR TO ANY WORK BEING UNDERTAKEN.ALL SERVICE CONNECTION APPROVALS AND REQUIREMENTS ARE TOBE OBTAINED AND CONFIRMED PRIOR TO ANY WORKS BEING UNDERTAKEN.WORKS ARE NOT TO BE UNDERTAKEN UNLESSPLANS ARE MARKED "CONSTRUCTION".DO NOT SCALE DRAWINGS - USE FIGURED DIMENSIONS ONLY.ANY ERRORS & OMISSIONS TO BE VERIFIED WITH THEDESIGNER PRIOR TO COMMENCEMENT ON SITE.

00 30/03/20 ISSUED FOR INTERNAL REVIEW AG01 06/04/20 ISSUED FOR CLIENT REVIEW & SIGNOFF DP02 27/08/20 ISSUED FOR CLIENT REVIEW & SIGNOFF SB

SECTION A-ASCALE 1:100@A3 SHEET

SECTION B-BSCALE 1:100@A3 SHEET

03 24/09/20 ISSUED FOR COUNCIL SUBMISSION SB

Page 10: NOT TO SCALE @A3 ARTIST IMPRESSION SUBM ION A RT ISMP …

CLIENT SIGNATURE DATE 19060Sheet No.:

Scale:Status:

Plot Date:

Project No:

Drawing Title:

Project Name

Client

COMMUNITY FACILITY

REV DATE AMENDMENT

24/9/20

/Volumes/Data/03 ARCHIVED PROJECTS/2019/19060 WALCHA MENS SHED/19060_sk2.pln

@ A3SUBMISSION

WD10

WET AREA DETAILS

172W FITZROY STREETWALCHANSW 2354

WALCHA MEN'S SHEDDT

5 15 20 25 50 7510 length in millimeters at full size 100

515

2025

5075

10le

ngth

in m

illim

eter

s at

full

size

100

S UBM IS S ION

900

950

100

800

350

2751751,390

150

2,55

0

CL

CT

MIRROR

P/MPBCR

C/CT

CLCL

SDPTD

600

150

2,55

0

P/MPBCR

C/CT

06-0

9SW

06-0

9SW

920

820

600

600

450

60

450

400

W03

W02 ACC. WC

WC

GR

GRBASIN

SDPTD

TRHUR

ACC.

SIG

N

PLUMBER TO PROVIDETHERMOSTATIC MIXING VALVETO ACC. WC IN ACCORDANCE

WITH AS 3500

ACCESSIBLE TOILET SEATS MUST HAVEA LUMINANCE CONTRAST OF 30% TO THE

BACKGROUND IN ACCORDANCE WITH AS1428.1

200955

60

450

300

4252751751,390

500

CL

CLCLCLC L

CL

500 500

600

150 600

200

460

50

800

250 805

1,40

095

0

955

2,55

0

1,20

0

150

100°

CL

C/CT

TRHBR

GR

GR

P/MPBCR

CL

CT600

400

460

140

200

150

450

950

600

300

2,55

0

CL

BRGR

WC

C/CT

P/MPBCR

720

300

240 200

300

800

BASIN

GENERAL DEVELOPMENT NOTESALL WORKS WITHIN ARE TO BE CARRIED OUT IN ACCORDANCE WITH THEBUILDING CODE OF AUSTRALIA & RELEVANT AUSTRALIAN STANDARDS.ALL WORKS DETAILED WITHIN THESE PLANS ARE TO BECARRIED OUT BY A RELEVANT LICENSED TRADESPERSON.ALL PRODUCTS & FIXTURES TO INSTALLED IN ACCORDANCE WITHMANUFACTURERS DETAILS & RELEVANT AUSTRALIAN STANDARDS.PLANS ARE TO BE READ IN CONJUNCTION WITH PLANS ANDDOCUMENTATION PROVIDED BY RELEVANT CONSULTANTSSUCH AS ENGINEERS, ENERGY ASSESSORS ETC.BOUNDARY LOCATIONS ARE TO BE CONFIRMED BYA REGISTERED SURVEYOR.

PROPOSED WORKS ARE TO BE SETOUT ON SITE BYA REGISTERED SURVEYOR.LEVELS ON PLANS ARE INDICATIVE ONLY & ARE TO BE CONFIRMED BYA REGISTERED SURVEYOR PRIOR TO CONSTRUCTION.ALL UNDERGROUND SERVICES AND LOCATIONS ARE TO BE CONFIRMEDPRIOR TO ANY WORK BEING UNDERTAKEN.ALL SERVICE CONNECTION APPROVALS AND REQUIREMENTS ARE TOBE OBTAINED AND CONFIRMED PRIOR TO ANY WORKS BEING UNDERTAKEN.WORKS ARE NOT TO BE UNDERTAKEN UNLESSPLANS ARE MARKED "CONSTRUCTION".DO NOT SCALE DRAWINGS - USE FIGURED DIMENSIONS ONLY.ANY ERRORS & OMISSIONS TO BE VERIFIED WITH THEDESIGNER PRIOR TO COMMENCEMENT ON SITE.

1

324

LEGENDB BASINMH MOP HOOKSFW FLOORWASTECL CENTRE LINECS CLEANER SINKT TUBCR CORNICEP/MPB PAINTED MOISTURE RESISTANCE PLASTERBOARDCT CERAMIC TILESV/SK VINYL SKIRTINGPTD PAPER TOWL DISPENSER

SD SOAP DISPENSERSHF SHELFTRH TOILET ROLL HOLDERFG FIXED GLASSV VINYL WALLSHEETINGEF EXHAUST FANBR BACK RESTFM FLICK MIXERGR GRAB RAILSNK SINKSG SLIDING GLASSDW DISHWASHERDH DOOR HANDLEPT PARTITION

00 30/03/20 ISSUED FOR INTERNAL REVIEW AG01 06/04/20 ISSUED FOR CLIENT REVIEW & SIGNOFF DP02 27/08/20 ISSUED FOR CLIENT REVIEW & SIGNOFF SB

PLUMBER TO PROVIDETHERMOSTATIC MIXING VALVETO ACC. WC IN ACCORDANCE

WITH AS 3500

ACCESSIBLE TOILET SEATS MUST HAVEA LUMINANCE CONTRAST OF 30% TO THE

BACKGROUND IN ACCORDANCE WITH AS1428.1

ACCESSIBLE TOILET SEATS MUST HAVEA LUMINANCE CONTRAST OF 30% TO THE

BACKGROUND IN ACCORDANCE WITH AS1428.1

03 24/09/20 ISSUED FOR COUNCIL SUBMISSION SB

Page 11: NOT TO SCALE @A3 ARTIST IMPRESSION SUBM ION A RT ISMP …

CLIENT SIGNATURE DATE 19060Sheet No.:

Scale:Status:

Plot Date:

Project No:

Drawing Title:

Project Name

Client

COMMUNITY FACILITY

REV DATE AMENDMENT

24/9/20

/Volumes/Data/03 ARCHIVED PROJECTS/2019/19060 WALCHA MENS SHED/19060_sk2.pln

@ A3SUBMISSION

WD11

DOOR CIRCULATIONS

172W FITZROY STREETWALCHANSW 2354

WALCHA MEN'S SHEDDT

5 15 20 25 50 7510 length in millimeters at full size 100

515

2025

5075

10le

ngth

in m

illim

eter

s at

full

size

100

S UBM IS S ION

WH D WL

L

WHD WL

L

WH D WL

L

D WL

L

L

WH D WL

L

WHD WL

L

WH D WL

L

WHD WL

L

WH D WL

L

WHD WL

L

WH D WL

L

D WL

DIMENSIOND

DIMENSIONL

DIMENSIONWH

DIMENSIONWL

850900950

1000 1140116011851220 560

510460410 340

340340340

DIMENSIOND

DIMENSIONL

DIMENSIONWH

DIMENSIONWL

850900950

1000 1155117512101240 240

19014090 660

660660660

DIMENSIOND

DIMENSIONL

DIMENSIONWH

DIMENSIONWL

850900950

1000 1155117512101240 560

510460410 660

660660660

DIMENSIOND

DIMENSIONL

DIMENSIONWH

DIMENSIONWL

850900950

1000 1450145014501450 0

000 510

510510510

HINGE - SIDE APPROACHDOOR OPENS TOWARDS USER

LATCH - SIDE APPROACHDOOR OPENS TOWARDS USER

EITHER SIDE APPROACHDOOR OPENS TOWARDS USER

FRONT APPROACHDOOR OPENS TOWARDS USER

DIMENSIOND

DIMENSIONL

DIMENSIONWH

DIMENSIONWL

850900950

1000 1670167016701670 660

610560510 900

900900900

DIMENSIOND

DIMENSIONL

DIMENSIONWH

DIMENSIONWL

850900950

1000 1670167016701670 110

110110110 900

900900900

DIMENSIOND

DIMENSIONL

DIMENSIONWH

DIMENSIONWL

850900950

1000 1670167016701670 660

610560510 900

900900900

DIMENSIOND

DIMENSIONL

DIMENSIONWH

DIMENSIONWL

850900950

1000 1450145014501450 110

110110110 530

530530530

HINGE - SIDE APPROACHDOOR OPENS AWAY FROM USER

LATCH - SIDE APPROACHDOOR OPENS AWAY FROM USER

EITHER SIDE APPROACHDOOR OPENS AWAY FROM USER

FRONT APPROACHDOOR OPENS AWAY FROM USER

DIMENSIOND

DIMENSIONL

DIMENSIONWH

DIMENSIONWL

850900950

1000 1280128012801280 660

610560510 395

395395395

DIMENSIOND

DIMENSIONL

DIMENSIONWH

DIMENSIONWL

850900950

1000 1230123012301230 185

180180180 660

660660660

DIMENSIOND

DIMENSIONL

DIMENSIONWH

DIMENSIONWL

850900950

1000 1280128012801280 660

610560510 660

660660660

DIMENSIOND

DIMENSIONL

DIMENSIONWH

DIMENSIONWL

850900950

1000 1450145014501450 0

000 530

530530530

EITHER SIDE APPROACH FRONT APPROACH

LASTCH - SIDE APPROACHSLIDE - SIDE APPROACH

CIRCULATION SPACES ATDOORWAYS WITH SWINGING DOORS

CIRCULATION SPACES ATDOORWAYS WITH SWINGING DOORS

CIRCULATION SPACES ATDOORWAYS WITH SLIDING DOORS

DL

WHWL

CLEAR OPENING OF DOORWAY WIDTHLENGTHWIDTH - HINGE SIDEWIDTH LATCH SIDEDIRECTION OF APPROACHCIRCULATION SPACE

LEGENDDL

WHWL

CLEAR OPENING OF DOORWAY WIDTHLENGTHWIDTH - HINGE SIDEWIDTH LATCH SIDEDIRECTION OF APPROACHCIRCULATION SPACE

LEGENDDL

WHWL

CLEAR OPENING OF DOORWAY WIDTHLENGTHWIDTH - HINGE SIDEWIDTH LATCH SIDEDIRECTION OF APPROACHCIRCULATION SPACE

LEGEND

TEMPLATE CIRCULATIONS SHOWN / SETUP FOR 920 DOOR

GENERAL DEVELOPMENT NOTESALL WORKS WITHIN ARE TO BE CARRIED OUT IN ACCORDANCE WITH THEBUILDING CODE OF AUSTRALIA & RELEVANT AUSTRALIAN STANDARDS.ALL WORKS DETAILED WITHIN THESE PLANS ARE TO BECARRIED OUT BY A RELEVANT LICENSED TRADESPERSON.ALL PRODUCTS & FIXTURES TO INSTALLED IN ACCORDANCE WITHMANUFACTURERS DETAILS & RELEVANT AUSTRALIAN STANDARDS.PLANS ARE TO BE READ IN CONJUNCTION WITH PLANS ANDDOCUMENTATION PROVIDED BY RELEVANT CONSULTANTSSUCH AS ENGINEERS, ENERGY ASSESSORS ETC.BOUNDARY LOCATIONS ARE TO BE CONFIRMED BYA REGISTERED SURVEYOR.

PROPOSED WORKS ARE TO BE SETOUT ON SITE BYA REGISTERED SURVEYOR.LEVELS ON PLANS ARE INDICATIVE ONLY & ARE TO BE CONFIRMED BYA REGISTERED SURVEYOR PRIOR TO CONSTRUCTION.ALL UNDERGROUND SERVICES AND LOCATIONS ARE TO BE CONFIRMEDPRIOR TO ANY WORK BEING UNDERTAKEN.ALL SERVICE CONNECTION APPROVALS AND REQUIREMENTS ARE TOBE OBTAINED AND CONFIRMED PRIOR TO ANY WORKS BEING UNDERTAKEN.WORKS ARE NOT TO BE UNDERTAKEN UNLESSPLANS ARE MARKED "CONSTRUCTION".DO NOT SCALE DRAWINGS - USE FIGURED DIMENSIONS ONLY.ANY ERRORS & OMISSIONS TO BE VERIFIED WITH THEDESIGNER PRIOR TO COMMENCEMENT ON SITE.

LEGENDB BASINMH MOP HOOKSFW FLOORWASTECL CENTRE LINECS CLEANER SINKT TUBCR CORNICEP/MPB PAINTED MOISTURE RESISTANCE PLASTERBOARDCT CERAMIC TILESV/SK VINYL SKIRTINGPTD PAPER TOWL DISPENSER

SD SOAP DISPENSERSHF SHELFTRH TOILET ROLL HOLDERFG FIXED GLASSV VINYL WALLSHEETINGEF EXHAUST FANBR BACK RESTFM FLICK MIXERGR GRAB RAILSNK SINKSG SLIDING GLASSDW DISHWASHERDH DOOR HANDLEPT PARTITION

00 30/03/20 ISSUED FOR INTERNAL REVIEW AG01 06/04/20 ISSUED FOR CLIENT REVIEW & SIGNOFF DP02 27/08/20 ISSUED FOR CLIENT REVIEW & SIGNOFF SB03 24/09/20 ISSUED FOR COUNCIL SUBMISSION SB

Page 12: NOT TO SCALE @A3 ARTIST IMPRESSION SUBM ION A RT ISMP …

CLIENT SIGNATURE DATE 19060Sheet No.:

Scale:Status:

Plot Date:

Project No:

Drawing Title:

Project Name

Client

COMMUNITY FACILITY

REV DATE AMENDMENT

24/9/20

/Volumes/Data/03 ARCHIVED PROJECTS/2019/19060 WALCHA MENS SHED/19060_sk2.pln

@ A3SUBMISSION

WD12

CONSTRUCTION DETAILS

172W FITZROY STREETWALCHANSW 2354

WALCHA MEN'S SHEDDT

5 15 20 25 50 7510 length in millimeters at full size 100

515

2025

5075

10le

ngth

in m

illim

eter

s at

full

size

100

S UBM IS S ION

EXAMPLE SIGN FOR UNISEXACCESSIBLE TOILET (RH) TRANSFER

EXAMPLE SIGNS FOR MALE/FEMALE TOILETS

EXAMPLE SIGNS FOR AMBULANT ACCESSIBLEMALE / FEMALE TOILETS

EXAMPLE WAYFINDING SIGN FORUNISEX ACCESSIBLE TOILET (LH) TRANSFER

EXAMPLE WAYFINDING SIGN FORUNISEX ACCESSIBLE TOILET (LH) TRANSFER

EXAMPLE WAYFINDING SIGN TO IDENTIFY FACILITIES FOR PERSONS WITH MOBILITY DISABILITIES

EXAMPLES OF ACCESSIBLE SIGNAGENOT TO SCALE

500 MIN

1,000

± 10

0

20 M

IN

35-4

5

35-45

EXAMPLE OF ACCEPTABLE DOOR HARDWAREFOR HINGED DOORS

NOT TO SCALE

- PLAN VIEW -

EXAMPLE OF ACCEPTABLE DOORHARDWARE FOR SLIDING DOORS

NOT TO SCALE

- SECTIONAL ELEVATION -

HEIGHTS FOR SWITCHESAND DOOR HANDLES

SCALE 1:25

CENTRE - LINE OF OPERATIVECOMPONENT NEAREST TOTHE INTERNAL CORNER

INTERNAL CORNEROR OBSTRUCTION

15 M

IN

50 MIN 30 TO 5086

5 TO

100

0 A

BO

VE

NO

SIN

G O

F TR

EA

DO

R S

UR

FAC

ES

600

MIN

25 +/- 1

35 +/- 1

NO OBSTRUCTIONNEAR HANDRAILABOVE THIS HEIGHTEXCEPT FOR SUPPORTIN THE SHADEDAREA ONLY

270° MIN

WAL

L

OBSTRUCTION

TYPICAL HANDRAIL DETAILSCALE 1:5

DISCRETEINDICATOR

COMPOSITEDISCRETEINDICATOR

BASE SURFACE

SLOPED UPPER

TACTILE INDICATOR DETAILSCALE 1:5

GENERAL DEVELOPMENT NOTESALL WORKS WITHIN ARE TO BE CARRIED OUT IN ACCORDANCE WITH THEBUILDING CODE OF AUSTRALIA & RELEVANT AUSTRALIAN STANDARDS.ALL WORKS DETAILED WITHIN THESE PLANS ARE TO BECARRIED OUT BY A RELEVANT LICENSED TRADESPERSON.ALL PRODUCTS & FIXTURES TO INSTALLED IN ACCORDANCE WITHMANUFACTURERS DETAILS & RELEVANT AUSTRALIAN STANDARDS.PLANS ARE TO BE READ IN CONJUNCTION WITH PLANS ANDDOCUMENTATION PROVIDED BY RELEVANT CONSULTANTSSUCH AS ENGINEERS, ENERGY ASSESSORS ETC.BOUNDARY LOCATIONS ARE TO BE CONFIRMED BYA REGISTERED SURVEYOR.

PROPOSED WORKS ARE TO BE SETOUT ON SITE BYA REGISTERED SURVEYOR.LEVELS ON PLANS ARE INDICATIVE ONLY & ARE TO BE CONFIRMED BYA REGISTERED SURVEYOR PRIOR TO CONSTRUCTION.ALL UNDERGROUND SERVICES AND LOCATIONS ARE TO BE CONFIRMEDPRIOR TO ANY WORK BEING UNDERTAKEN.ALL SERVICE CONNECTION APPROVALS AND REQUIREMENTS ARE TOBE OBTAINED AND CONFIRMED PRIOR TO ANY WORKS BEING UNDERTAKEN.WORKS ARE NOT TO BE UNDERTAKEN UNLESSPLANS ARE MARKED "CONSTRUCTION".DO NOT SCALE DRAWINGS - USE FIGURED DIMENSIONS ONLY.ANY ERRORS & OMISSIONS TO BE VERIFIED WITH THEDESIGNER PRIOR TO COMMENCEMENT ON SITE.

LEGENDB BASINMH MOP HOOKSFW FLOORWASTECL CENTRE LINECS CLEANER SINKT TUBCR CORNICEP/MPB PAINTED MOISTURE RESISTANCE PLASTERBOARDCT CERAMIC TILESV/SK VINYL SKIRTINGPTD PAPER TOWL DISPENSER

SD SOAP DISPENSERSHF SHELFTRH TOILET ROLL HOLDERFG FIXED GLASSV VINYL WALLSHEETINGEF EXHAUST FANBR BACK RESTFM FLICK MIXERGR GRAB RAILSNK SINKSG SLIDING GLASSDW DISHWASHERDH DOOR HANDLEPT PARTITION

00 30/03/20 ISSUED FOR INTERNAL REVIEW AG01 06/04/20 ISSUED FOR CLIENT REVIEW & SIGNOFF DP02 27/08/20 ISSUED FOR CLIENT REVIEW & SIGNOFF SB03 24/09/20 ISSUED FOR COUNCIL SUBMISSION SB